         KYL-200U Micro Power Wireless
           Transceiver Data Module




Shenzhen KYL Communication Equipment Co., Ltd

Address: Unit 5-7, Building3, Huangdu Square, South of Exhibition Center, Yitian
Road, Futian District, Shenzhen Guangdong China

Tel: +0086-755-83410815
Fax: +0086-755-83408785
Skype
Skype:lxmlosia
Yahoo messenger: losia2012@yahoo.com
MSN: kylcom01.com@hotmail.com
E_mail: sales01@rf-data.com /kyl03losia@gmail.com
Website: http://www.rf-data.com




Fax: +0086-755-83408785
      0086- 755-83408785    kyl03losia@gmail.com     www.rf-data.com               1
Shenzhen KYL Communication Equipment Co., Ltd
             Shenz                                Co.

Catalogue
I. About KYL-200U ....................................................................3

II. Features of KYL-200U ..........................................................3

III. Applications of KYL-200U.................................................. 4

IV. How to use KYL-200U..........................................................4
               KYL-200U..........................................................4

V. Networking Application of KYL-200U............................... 14

VI. Technical specification of KYL-200U................................ 14

VII. Description of type.............................................................. 15




Fax: +0086-755-83408785
      0086- 755-83408785        kyl03losia@gmail.com         www.rf-data.com                2
Shenzhen KYL Communication Equipment Co., Ltd
            Shenz                                Co.

Before using the product please read the use manual carefully.
Any question in technical, you can contact us.
Tel: +0086-755-83410815.

I: About KYL-200U
KYL-200U, the micro power wireless transceiver data module is used as the wireless
data transceiver in short-ranges, with the small size, weight and power consumption
and good stability and reliability. Narrowband low power UHF wireless data
transmitters and receivers with channel spacing as low as 25 KHz.

II: Features:
I. Features of KYL-200U
1. Low power transmission with 10mW, 50~100mW is available if needed.
2. With 433MHz as factory default carrier frequency, but 400-470MHz, 868MHz,
   915MHz is available if needed.
3. High anti- interference and Low BER (Bit error Rate)
   Based on the Gaussian Frequency Shift Keying (GFSK) modulation, the
   high-efficiency forward error correction channel encoding technology is used to
   enhance data’s resistance to both transient interference and random interference and
   the actual bit error rate of 10-5 ~ 10-6 can be achieved when channel bit error rate is
   10-2.
4. Long Transmission Distance
   Within the visible range, when the height of antenna is higher than 2m and The Bit
   Error Rate (BER) is 10-3, the reliable transmission distances respectively is 1000m
   @1200bps, and is 600m@9600bps.
5. Transparent data transmission
   Transparent data interface used in transceivers is for meeting many standard or
   nonstandard user protocols. Any false data generated in air can be filtrated
   automatically (What has been received is exactly what has been transmitted).
6. Multi-channels
   KYL-200U transceivers offer 8 channels, if needed, 16 or 32 channels are available
   to satisfy various configuration of communication under user’s demand at the same
   time.
7. 2 ports with three connection methods
   KYL-200U transceivers provide 2 ports with three connections, ports: a UART
   interface of TTL level, a non-standard RS-232 port and a non-standard RS-485
   port.
8. Big data buffer area
   With optional interface baud rate: 1200/4800/9600/19200bps and 8N1/8E1/8O1
   data format (set by user), the transceiver can transmit unlimited data frames with
   flexible user program.
   Note: the RF data rate is only settled down before delivery, please inform our sales
   when placing your orders.
Fax: +0086-755-83408785
      0086- 755-83408785      kyl03losia@gmail.com        www.rf-data.com               3
Shenzhen KYL Communication Equipment Co., Ltd
            Shenz                                Co.

9. Intelligent data control and no any extra programs required
   Even for half duplex communication, no any excessive programs required. All RF
   system data transmission/reception and other On-the-Fly conversion and control are
   performed by KYL-200U transceivers automatically.
10. Lower power consumption & Sleep function
    With +5V power, the receiving current is less than 20mA, the transmitting current
    is less than 40mA, and the sleeping current is less than 20uA.
11. High reliability, small and light
    By using monolithic radio-frequency integrated circuit and single-chip MCU, the
    transceivers have less peripheral circuit s, high reliability, and low failure rate.
12. More options of configurable antennas for user different applications.
13. Watchdog monitor
    Watchdog monitors the inner function, so it can change the traditional product
    structure and also improve the reliability of our modules.


III: Application of KYL-200U:
KYL-200U the micro power wireless transceiver data module is suitable for:
* AMR Automatic Meter Reading
* Wireless alarm and security systems
* Building automation, security, wireless monitoring and control of room equipment,
 Access Control System;
* Wireless data transmission, automatic data collection system;
* Radio modem can be used for Sports training & competition;
* Wireless dishes ordering;
* Wireless POS, PDA wireless smart terminal;
* RF modem can be used for Electronic bus station and intelligent traffic;
* RF transmitter Wireless electronic display screen and queuing machine;
* Wireless telemetry Charging for parking, parking lot;
* Wireless modem Automobile inspection and four-wheel orientation;
* Wireless sensor Industrial wireless remote control and air conditioning remote
controller;
* Data communication used for railway, oil field, dock and army.
* LED display in thruway and public places
* Point to multi-point wireless network, wireless on-the-spot bus and automatic data
collection system;


IV: How to use the KYL-200U
KYL-200U provide RS-232, RS-485 and UART/TTL level interface port for direct
connection with PC, RS485 devices, monolithic processors and other UART
components kinds of applications. The schematic diagram is shown below:


Fax: +0086-755-83408785
      0086- 755-83408785     kyl03losia@gmail.com        www.rf-data.com              4
Shenzhen KYL Communication Equipment Co., Ltd
                  Shenz                                Co.




      1. Power supply
         The factory default setting is +5V(3.3-3.6V will inform when placing the order).By
         using better ripple factor, KYL-200U transceivers can also share power supply with
         other equipment. If possible, a voltage-stabilizing chip with 5V voltage is more
         recommended as the only power supply than Switch power supply. But if only
         switch power supply available, the jam by switch pulse to the transceivers should
         be avoided. In addition, the reliable grounding must be used if there is other device
         in the system equipment. In case of failing to connect with the ground, it can form
         its own grounding but must be absolutely separated from the municipal electric
         supply.
      2. Connection Definition with terminal
         KYL-200U transceivers supply one 9-pin connector (JP1), their definitions and
         connection methods with terminals are shown in Table 1.

       Table 1: JP1 Pin Definitions and connection methods
Pin No. Signal Name                Function                Level          Connection       Remarks
                                                                         with terminal
  1        GND             Grounding of power supply                        Ground

  2         Vcc                 Power supply DC                  5V

  3      RxD/TTL       Serial data input to the transceiver     TTL           TxD

  4      TxD/TTL           Transmitted data out of the          TTL           RxD
                                  transceiver
  5        SGND                      Signal
  6       A (TXD)         A of RS-485(TxD of RS-232)                        A(RxD)
  7       B (RXD)         B of RS-485(RxD of RS-232)                        B(TxD)
  8        SLEEP              Sleep control (input)             TTL       Sleep signal    High level
                                                                                             sleep
  9       RESET                Reset signal(input)              TTL                        Negative
                                                                                          pulse reset


      Fax: +0086-755-83408785
            0086- 755-83408785     kyl03losia@gmail.com        www.rf-data.com              5
Shenzhen KYL Communication Equipment Co., Ltd
              Shenz                                Co.

3. The connection schematic diagram between computer and our
RF module




4. Setting of channel, interface, and data format
    Before using KYL-200U, the user needs to make simple configuration based on
    its own needs to determine the channel,interface mode and data format. The user
    can change or view the module's interface baud rate, channel and address code.
    Parameter setting or reading as per the testing software KYLCOM.exe in the PC
    (in products box).And the configuration is as follows:
i. Channel configuration:
    Channel No.         Frequency           Channel No.           Frequency
          1            429.0325MHZ                5             433.0325MHZ
          2            430.0325MHZ                6             434.0325MHZ
          3            431.0325MHZ                7             435.0325MHZ
          4            432.0325MHZ                8             436.0325MHZ

    Note: the frequency points corresponding to each channel can be adjusted
    based on the user’s needs.
                 user’
ii. The schematic diagram of setting the parameter as follows:
      a. Connect the PC and module with RS232 data cable.
      b. Open the “KYLCOM” PC software, select “English” as follows:




Fax: +0086-755-83408785
      0086- 755-83408785    kyl03losia@gmail.com       www.rf-data.com                6
Shenzhen KYL Communication Equipment Co., Ltd
           Shenz                                Co.




c. Click “open port”, then will open a small window as the following picture, clients
   will write the parameters in this windows.




d. Click “read paras”.
   “Read correct” show your connection between KYL module and PC is correct.




Fax: +0086-755-83408785
      0086- 755-83408785     kyl03losia@gmail.com       www.rf-data.com                 7
Shenzhen KYL Communication Equipment Co., Ltd
            Shenz                                Co.




If you want to change some technical parameter, you need do as follows.
e. User can change the parameter such as channel and interface
    rate and Parity mode according to actual demand through the button of the left
    window. After writing the parameters in the left catalogue, click the “write para”,
    then will show “write correct”. So you have finished the process for changing
    technical parameter.




Fax: +0086-755-83408785
      0086- 755-83408785      kyl03losia@gmail.com       www.rf-data.com              8
Shenzhen KYL Communication Equipment Co., Ltd
           Shenz                                Co.




Note: The RF data rate(Air Rate) can not be set by user, it is confirmed when
placing orders and set before delivery. So please confirm the RF data rate when
placing the order.

5. Installation dimension:




Fax: +0086-755-83408785
      0086- 755-83408785     kyl03losia@gmail.com   www.rf-data.com           9
Shenzhen KYL Communication Equipment Co., Ltd
            Shenz                                Co.




6. The Function-indicator light
   a. The LED indicator light will glitter red for 0.5S once after switched on.
   b. The LED indicator light will glitter green continually while receiving data from
      air.
   c. The LED indicator light will glitter red continuously when transmitting data into
      air after receiving from COM.
   d. If the module enables the sleep function, LED indicator light is always dark.
7. Supported protocol and Transmit capability
   KYL-200U standard transceivers offer transparent protocol to support various
   applications and protocols of users. If the user needs to decrease his cost or ease the
   workload of terminal CPU, we can add other specific functions based on the
   transparent protocol, such as addressing, data acquisition, command interpretation,
   etc.
8. Sleep function instruction:
   Due to reducing more consumption, KYL-200U transceivers support Sleep function.
   In sleep mode, the current consumption is less than 20uA.

  a. How to use the Sleep function:
     The Pin8 ‘SLP’ in JP1 is the signal of sleep control. In high power level,
     transceiver stays in working mode. In low power level (<0.5V), transceiver stays
     in sleep mode. The SLP signal can convert transceiver from working to sleep
     mode in 1ms after falling edge. If the Sleep signal arrives when the transceiver is
     transmitting data, the module will enter sleep mode after finishing transmission.
     From sleep mode to working, it takes the transceiver 1ms after rising edge.
     To disable the opened sleep function of KYL-200U, the SLP (SLEEP) pin
     should be definitely connected with 0 or ground.
  b. Attentions about use of sleep function:
     When the sleep function enabled, any supply glitches, such as switch dithering,
Fax: +0086-755-83408785
      0086- 755-83408785      kyl03losia@gmail.com       www.rf-data.com               10
Shenzhen KYL Communication Equipment Co., Ltd
            Shenz                                Co.

    fire striking or quick switching on and off, could cause the transceiver to be
    switched to the wrong sleep mode.
    After switching on, users can avoid this error by making a compulsive
    restoration once after the CPU delays 100ms.
    Sleep Timing Diagram:




9. The attentions of data transmission
   a. The delay time (tc) of conversion between transmitting and receiving is less than
1ms.
Timing diagram:




  b. The delay time of transceivers between the first bit sent by TxD to the first
      bit received by RxD.
    Due to a data processing will be made on user’s data by KYL-200U transceiver
    using FEC (Forward Error Correction) or other correction algorithm, when RxD
    of a KYL-200U transceiver ‘A’ receives the data, then transmits it, the other one
    transceiver ‘B’ will have a delay (ts) to receive and transmit by TxD. Different
    RF data rate causes different delay time. Please see the specific delay time
    below:

Fax: +0086-755-83408785
      0086- 755-83408785     kyl03losia@gmail.com       www.rf-data.com              11
Shenzhen KYL Communication Equipment Co., Ltd
           Shenz                                Co.

       RF Date Rate        Delay          RF Date Rate              Delay
          (bps)            Ts(mS)            (bps)                  Ts(mS)
          1200               90              9600                     16
           2400               48              19200                   10
           4800               30


Timing diagram:




  c. Error dealing procedure:
     To enhance the reliability and stability of user’s systems, a verify bit or a Cyclic
     Redundancy Check (CRC) mode is highly recommended to resent the wrong
     information while using KYL-200U modules.
  d. Large-number data transmission
     In theory, when the interface data rate is faster than the RF data rate, KYL-200U
     transceivers can sent unlimited-long data package, but any long packages more
     than 120B are not recommended. The length of each package should be between
     60~100B. We also recommend user to resent the wrong information using
     Automatic Error Request Equipment (ARQ).
     The analyzing as below:
     What if the actual transmission BER (Bit Error Rate) is 10-4, 1 packet with 1KB
     data, which is about 10-thousand bits, is sent, theoretically, at least 1 bit will be
     received wrongly, then the 1KB information will never be received correctly.
     But if we package the data into 10 packets with 100B for each, when all 10
     packets are sent, there will be only 1 packet wrong according to this probability.
     After that, resend this wrong packet using ARQ mode. So by resending one more
     packet and the efficiency rate is reduced 10%, all data will be absolutely received
     correctly.

10. Antenna configuration:
    Many appropriative antennas for low power RF modules are selected for meeting
    different user antenna configurations. Please ask our Sales office for further
Fax: +0086-755-83408785
      0086- 755-83408785      kyl03losia@gmail.com        www.rf-data.com               12
Shenzhen KYL Communication Equipment Co., Ltd
            Shenz                                Co.

    information about the antenna’s dimension and performance.
a. Helical SMA antennas
   KYL-ANT-433-10-SMA: 100mm helical SMA antennas with high gain and low
   cost, reach a long distance.




KYL-ANT-433-3-SMA: 28mm SMA helical antenna with magnetic core, small size,
beautiful appearance (like the mobile phone antenna)




KYL-ANT-433-10-ZSMA: 100mm SMA helical antenna with folding joint, easy for
adjusting the direction and fixing.




b. Magnetic vehicle antenna
   KYL-ANT-O433S-300H1.5-SMA: include magnetic antenna base, suitable for
   equipment with metal shell, easy for fixing, effective to enhance the transmission
   distance.




More kinds of antenna, please browse our website:
http://www.rf-data.com/Products_list_en.asp?classid=163
If the user has special demands on antennas, we can design and produce for them
specially.


V. Networking Application of KYL-200U
     The communication channel of KYL-200U is half duplex, which is most suitable
     for the communication mode of point to multi-point. Under this mode, one
     master station must be set, and all of the rest are slave stations. A unique address
Fax: +0086-755-83408785
      0086- 755-83408785      kyl03losia@gmail.com       www.rf-data.com                13
Shenzhen KYL Communication Equipment Co., Ltd
          Shenz                                Co.

    is given to each station. The coordination of communication is controlled by
    master station that uses data frames containing address code to transmit data or
    command. Slave station will receive all of the data and command and compare
    the received address code with local address code. If they are different, the data
    will be deserted without any response. If those address codes are the same, it
    means the data is sent to the local. Slave station will make different responses
    according to the transmitted data or command and send back the data of response.
    All these jobs must be performed by upper protocol, and it is assured that there is
    only one transmitter-receiver in the state of transmission in the communication
    network at any instant moment so as to avoid the cross-interference.
    KYL-200U can also be used for point-to-point communication with easier
    operation. For the programming of serial port, all you have to do is to remember
    that its communication mode is semi duplex while always observing the time
    sequence of come-and-go for receiving and transmitting.


VI. Technical specification of KYL-200U
* Modulation mode: GFSK/FSK
* Working frequency: 400MHz~470MHz, 868MHz, 915MHz;
* Power supply: DC 5V (3.3~3.6V informed when placing the order);
* RF power: ≤10mW, 50mW~100mW is available;
* RF data rate: 1200/2400/4800/9600/19200bps (Set before delivery);
* Receive current: <20mA (TTL connect);
* Receive sensitivity: -120dBm (1200bps); -115dBm (9600bps);
* Transmitting current: <40mA;
* Sleep current: <20uA;
* Interface data format: 8E1/8N1/8O1;
* Working humidity: 10%~90% relative humidity without condensation;
* Working temperature: -35℃~+75℃( industrial)
* RF Line-of-sight Range: 600m(BER=10-5@9600bps);
                           1000m(BER=10-5@1200bps);
* Size: 47mm*26mm*10mm (without antenna port).




Fax: +0086-755-83408785
      0086- 755-83408785    kyl03losia@gmail.com       www.rf-data.com              14
Shenzhen KYL Communication Equipment Co., Ltd
          Shenz                                Co.

VII. Description of type



           KYL-200U-96
                                  Baud Rate
                                 12:1200bps
      manufacturer     type
                                 24:2400bps
                                 48:4800bps
                                 96:9600bps
                                 192:19200bps




Fax: +0086-755-83408785
      0086- 755-83408785   kyl03losia@gmail.com   www.rf-data.com   15

More Related Content

What's hot

Kyl 300 h user manual
Kyl 300 h user manualKyl 300 h user manual
Kyl 300 h user manualkyl03losia
 
Kyl 200l user manual
Kyl 200l user manualKyl 200l user manual
Kyl 200l user manualSunny Zhou
 
KYL 500I user manaul
KYL  500I user manaulKYL  500I user manaul
KYL 500I user manaulSunny Zhou
 
KYL 300H wireless module user manual
KYL 300H wireless module user manualKYL 300H wireless module user manual
KYL 300H wireless module user manualSunny Zhou
 
KYL-500S user manual
KYL-500S user manualKYL-500S user manual
KYL-500S user manualkyl03losia
 
Kyl 210 user manual
Kyl 210 user manualKyl 210 user manual
Kyl 210 user manualkyl03losia
 
Kyl 200 l user manual
Kyl 200 l user manualKyl 200 l user manual
Kyl 200 l user manualSunny Zhou
 
KYL 210 RF Module user manual
KYL 210 RF Module user manualKYL 210 RF Module user manual
KYL 210 RF Module user manualSunny Zhou
 
500mW, 1W RF Data Transmitter, 433MHz RF Module
500mW, 1W RF Data Transmitter, 433MHz RF Module500mW, 1W RF Data Transmitter, 433MHz RF Module
500mW, 1W RF Data Transmitter, 433MHz RF ModuleSunny Zhou
 
Kyl 600 l user manual1
Kyl 600 l user manual1Kyl 600 l user manual1
Kyl 600 l user manual1kyl03losia
 
Kyl 816 analog acquisition module
Kyl 816 analog acquisition moduleKyl 816 analog acquisition module
Kyl 816 analog acquisition moduleSunny Zhou
 
Advanced motion controls mc1xdzr02 qd
Advanced motion controls mc1xdzr02 qdAdvanced motion controls mc1xdzr02 qd
Advanced motion controls mc1xdzr02 qdElectromate
 
JVL Profibus Expansion Modules MAC00-FP2 & MAC00-FP4
JVL Profibus Expansion Modules MAC00-FP2 & MAC00-FP4JVL Profibus Expansion Modules MAC00-FP2 & MAC00-FP4
JVL Profibus Expansion Modules MAC00-FP2 & MAC00-FP4Electromate
 
Kyl 500 s data transceiver
Kyl 500 s data transceiverKyl 500 s data transceiver
Kyl 500 s data transceiverSunny Zhou
 
KYL-200L wireless data transmission RF module for 2-3km
KYL-200L wireless data transmission RF module for 2-3km KYL-200L wireless data transmission RF module for 2-3km
KYL-200L wireless data transmission RF module for 2-3km Minerva Zhao
 

What's hot (17)

Kyl 300 h user manual
Kyl 300 h user manualKyl 300 h user manual
Kyl 300 h user manual
 
Kyl 200l user manual
Kyl 200l user manualKyl 200l user manual
Kyl 200l user manual
 
KYL 500I user manaul
KYL  500I user manaulKYL  500I user manaul
KYL 500I user manaul
 
KYL 300H wireless module user manual
KYL 300H wireless module user manualKYL 300H wireless module user manual
KYL 300H wireless module user manual
 
KYL-500S user manual
KYL-500S user manualKYL-500S user manual
KYL-500S user manual
 
Kyl 210 user manual
Kyl 210 user manualKyl 210 user manual
Kyl 210 user manual
 
Kyl 200 l user manual
Kyl 200 l user manualKyl 200 l user manual
Kyl 200 l user manual
 
KYL 210 RF Module user manual
KYL 210 RF Module user manualKYL 210 RF Module user manual
KYL 210 RF Module user manual
 
Kyl 500
Kyl 500 Kyl 500
Kyl 500
 
500mW, 1W RF Data Transmitter, 433MHz RF Module
500mW, 1W RF Data Transmitter, 433MHz RF Module500mW, 1W RF Data Transmitter, 433MHz RF Module
500mW, 1W RF Data Transmitter, 433MHz RF Module
 
Kyl 600 l user manual1
Kyl 600 l user manual1Kyl 600 l user manual1
Kyl 600 l user manual1
 
576664
576664576664
576664
 
Kyl 816 analog acquisition module
Kyl 816 analog acquisition moduleKyl 816 analog acquisition module
Kyl 816 analog acquisition module
 
Advanced motion controls mc1xdzr02 qd
Advanced motion controls mc1xdzr02 qdAdvanced motion controls mc1xdzr02 qd
Advanced motion controls mc1xdzr02 qd
 
JVL Profibus Expansion Modules MAC00-FP2 & MAC00-FP4
JVL Profibus Expansion Modules MAC00-FP2 & MAC00-FP4JVL Profibus Expansion Modules MAC00-FP2 & MAC00-FP4
JVL Profibus Expansion Modules MAC00-FP2 & MAC00-FP4
 
Kyl 500 s data transceiver
Kyl 500 s data transceiverKyl 500 s data transceiver
Kyl 500 s data transceiver
 
KYL-200L wireless data transmission RF module for 2-3km
KYL-200L wireless data transmission RF module for 2-3km KYL-200L wireless data transmission RF module for 2-3km
KYL-200L wireless data transmission RF module for 2-3km
 

Similar to KYL-200U Micro Power Wireless Data Module Specification Sheet

Kyl 200 u rf module user manual
Kyl 200 u rf module user manualKyl 200 u rf module user manual
Kyl 200 u rf module user manualSunny Zhou
 
KYL-500L user manaul
KYL-500L user manaulKYL-500L user manaul
KYL-500L user manaulkyl03losia
 
KYL-500L500 user manaul
KYL-500L500 user manaulKYL-500L500 user manaul
KYL-500L500 user manaulkyl03losia
 
KKYL- 500L user manaul
KKYL- 500L user manaulKKYL- 500L user manaul
KKYL- 500L user manaulkyl03losia
 
10mW-100mW RF Module RS232, RS485 to Wireless
10mW-100mW RF Module RS232, RS485 to Wireless10mW-100mW RF Module RS232, RS485 to Wireless
10mW-100mW RF Module RS232, RS485 to WirelessSunny Zhou
 
Kyl 816 wireless ON-OFF module user manual
Kyl 816 wireless ON-OFF module user manualKyl 816 wireless ON-OFF module user manual
Kyl 816 wireless ON-OFF module user manualSunny Zhou
 
Radio Module KYL-300H 8-10 km RS232/RS485/TTL Wireless data transmission modu...
Radio Module KYL-300H 8-10 km RS232/RS485/TTL Wireless data transmission modu...Radio Module KYL-300H 8-10 km RS232/RS485/TTL Wireless data transmission modu...
Radio Module KYL-300H 8-10 km RS232/RS485/TTL Wireless data transmission modu...Minerva Zhao
 
Kyl 816 user manual
Kyl 816 user manualKyl 816 user manual
Kyl 816 user manualkyl03losia
 
LS-U1000 rf module
LS-U1000 rf moduleLS-U1000 rf module
LS-U1000 rf moduleSunny Chou
 
Powerline Communcation For Home Automation
Powerline Communcation For Home AutomationPowerline Communcation For Home Automation
Powerline Communcation For Home AutomationGaurav Everyones
 
QuickSilver Controls QCI-DS018 QCI-D2-IG8
QuickSilver Controls QCI-DS018 QCI-D2-IG8QuickSilver Controls QCI-DS018 QCI-D2-IG8
QuickSilver Controls QCI-DS018 QCI-D2-IG8Electromate
 
LS-U1000P radio modem
LS-U1000P radio modemLS-U1000P radio modem
LS-U1000P radio modemSunny Chou
 
Drt scanner 4301 wcdma
Drt scanner   4301 wcdmaDrt scanner   4301 wcdma
Drt scanner 4301 wcdmamarcosaoc
 
huawei-s5735-s8p2x-ia200h1-brochure-datasheet.pdf
huawei-s5735-s8p2x-ia200h1-brochure-datasheet.pdfhuawei-s5735-s8p2x-ia200h1-brochure-datasheet.pdf
huawei-s5735-s8p2x-ia200h1-brochure-datasheet.pdfHi-Network.com
 
dwdm-sfp10g-40km-c20-optic-transceiver-module-141081.doc
dwdm-sfp10g-40km-c20-optic-transceiver-module-141081.docdwdm-sfp10g-40km-c20-optic-transceiver-module-141081.doc
dwdm-sfp10g-40km-c20-optic-transceiver-module-141081.docGLsun Mall
 
DWDM-SFP10G-40-C35-T02#141081.pdf
DWDM-SFP10G-40-C35-T02#141081.pdfDWDM-SFP10G-40-C35-T02#141081.pdf
DWDM-SFP10G-40-C35-T02#141081.pdfGLsun Mall
 

Similar to KYL-200U Micro Power Wireless Data Module Specification Sheet (17)

Kyl 200 u rf module user manual
Kyl 200 u rf module user manualKyl 200 u rf module user manual
Kyl 200 u rf module user manual
 
KYL-500L user manaul
KYL-500L user manaulKYL-500L user manaul
KYL-500L user manaul
 
KYL-500L500 user manaul
KYL-500L500 user manaulKYL-500L500 user manaul
KYL-500L500 user manaul
 
KKYL- 500L user manaul
KKYL- 500L user manaulKKYL- 500L user manaul
KKYL- 500L user manaul
 
10mW-100mW RF Module RS232, RS485 to Wireless
10mW-100mW RF Module RS232, RS485 to Wireless10mW-100mW RF Module RS232, RS485 to Wireless
10mW-100mW RF Module RS232, RS485 to Wireless
 
Kyl 816 wireless ON-OFF module user manual
Kyl 816 wireless ON-OFF module user manualKyl 816 wireless ON-OFF module user manual
Kyl 816 wireless ON-OFF module user manual
 
Kyl 816 Wirel
Kyl 816 WirelKyl 816 Wirel
Kyl 816 Wirel
 
Radio Module KYL-300H 8-10 km RS232/RS485/TTL Wireless data transmission modu...
Radio Module KYL-300H 8-10 km RS232/RS485/TTL Wireless data transmission modu...Radio Module KYL-300H 8-10 km RS232/RS485/TTL Wireless data transmission modu...
Radio Module KYL-300H 8-10 km RS232/RS485/TTL Wireless data transmission modu...
 
Kyl 816 user manual
Kyl 816 user manualKyl 816 user manual
Kyl 816 user manual
 
LS-U1000 rf module
LS-U1000 rf moduleLS-U1000 rf module
LS-U1000 rf module
 
Powerline Communcation For Home Automation
Powerline Communcation For Home AutomationPowerline Communcation For Home Automation
Powerline Communcation For Home Automation
 
QuickSilver Controls QCI-DS018 QCI-D2-IG8
QuickSilver Controls QCI-DS018 QCI-D2-IG8QuickSilver Controls QCI-DS018 QCI-D2-IG8
QuickSilver Controls QCI-DS018 QCI-D2-IG8
 
LS-U1000P radio modem
LS-U1000P radio modemLS-U1000P radio modem
LS-U1000P radio modem
 
Drt scanner 4301 wcdma
Drt scanner   4301 wcdmaDrt scanner   4301 wcdma
Drt scanner 4301 wcdma
 
huawei-s5735-s8p2x-ia200h1-brochure-datasheet.pdf
huawei-s5735-s8p2x-ia200h1-brochure-datasheet.pdfhuawei-s5735-s8p2x-ia200h1-brochure-datasheet.pdf
huawei-s5735-s8p2x-ia200h1-brochure-datasheet.pdf
 
dwdm-sfp10g-40km-c20-optic-transceiver-module-141081.doc
dwdm-sfp10g-40km-c20-optic-transceiver-module-141081.docdwdm-sfp10g-40km-c20-optic-transceiver-module-141081.doc
dwdm-sfp10g-40km-c20-optic-transceiver-module-141081.doc
 
DWDM-SFP10G-40-C35-T02#141081.pdf
DWDM-SFP10G-40-C35-T02#141081.pdfDWDM-SFP10G-40-C35-T02#141081.pdf
DWDM-SFP10G-40-C35-T02#141081.pdf
 

Recently uploaded

Connect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationConnect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationSlibray Presentation
 
APIForce Zurich 5 April Automation LPDG
APIForce Zurich 5 April  Automation LPDGAPIForce Zurich 5 April  Automation LPDG
APIForce Zurich 5 April Automation LPDGMarianaLemus7
 
Advanced Test Driven-Development @ php[tek] 2024
Advanced Test Driven-Development @ php[tek] 2024Advanced Test Driven-Development @ php[tek] 2024
Advanced Test Driven-Development @ php[tek] 2024Scott Keck-Warren
 
SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024Scott Keck-Warren
 
Understanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitectureUnderstanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitecturePixlogix Infotech
 
Unraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdfUnraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdfAlex Barbosa Coqueiro
 
"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack
"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack
"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek SchlawackFwdays
 
CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):comworks
 
Human Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsHuman Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsMark Billinghurst
 
Ensuring Technical Readiness For Copilot in Microsoft 365
Ensuring Technical Readiness For Copilot in Microsoft 365Ensuring Technical Readiness For Copilot in Microsoft 365
Ensuring Technical Readiness For Copilot in Microsoft 3652toLead Limited
 
Install Stable Diffusion in windows machine
Install Stable Diffusion in windows machineInstall Stable Diffusion in windows machine
Install Stable Diffusion in windows machinePadma Pradeep
 
Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Mattias Andersson
 
Pigging Solutions in Pet Food Manufacturing
Pigging Solutions in Pet Food ManufacturingPigging Solutions in Pet Food Manufacturing
Pigging Solutions in Pet Food ManufacturingPigging Solutions
 
Gen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfGen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfAddepto
 
Scanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsScanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsRizwan Syed
 
"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr Bagan"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr BaganFwdays
 
Developer Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQLDeveloper Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQLScyllaDB
 
SAP Build Work Zone - Overview L2-L3.pptx
SAP Build Work Zone - Overview L2-L3.pptxSAP Build Work Zone - Overview L2-L3.pptx
SAP Build Work Zone - Overview L2-L3.pptxNavinnSomaal
 
Streamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupStreamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupFlorian Wilhelm
 

Recently uploaded (20)

Connect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationConnect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck Presentation
 
APIForce Zurich 5 April Automation LPDG
APIForce Zurich 5 April  Automation LPDGAPIForce Zurich 5 April  Automation LPDG
APIForce Zurich 5 April Automation LPDG
 
Advanced Test Driven-Development @ php[tek] 2024
Advanced Test Driven-Development @ php[tek] 2024Advanced Test Driven-Development @ php[tek] 2024
Advanced Test Driven-Development @ php[tek] 2024
 
SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024
 
Understanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitectureUnderstanding the Laravel MVC Architecture
Understanding the Laravel MVC Architecture
 
Unraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdfUnraveling Multimodality with Large Language Models.pdf
Unraveling Multimodality with Large Language Models.pdf
 
"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack
"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack
"Subclassing and Composition – A Pythonic Tour of Trade-Offs", Hynek Schlawack
 
CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):
 
Human Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsHuman Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR Systems
 
Ensuring Technical Readiness For Copilot in Microsoft 365
Ensuring Technical Readiness For Copilot in Microsoft 365Ensuring Technical Readiness For Copilot in Microsoft 365
Ensuring Technical Readiness For Copilot in Microsoft 365
 
Install Stable Diffusion in windows machine
Install Stable Diffusion in windows machineInstall Stable Diffusion in windows machine
Install Stable Diffusion in windows machine
 
Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?
 
Pigging Solutions in Pet Food Manufacturing
Pigging Solutions in Pet Food ManufacturingPigging Solutions in Pet Food Manufacturing
Pigging Solutions in Pet Food Manufacturing
 
DMCC Future of Trade Web3 - Special Edition
DMCC Future of Trade Web3 - Special EditionDMCC Future of Trade Web3 - Special Edition
DMCC Future of Trade Web3 - Special Edition
 
Gen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfGen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdf
 
Scanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsScanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL Certs
 
"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr Bagan"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr Bagan
 
Developer Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQLDeveloper Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQL
 
SAP Build Work Zone - Overview L2-L3.pptx
SAP Build Work Zone - Overview L2-L3.pptxSAP Build Work Zone - Overview L2-L3.pptx
SAP Build Work Zone - Overview L2-L3.pptx
 
Streamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupStreamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project Setup
 

KYL-200U Micro Power Wireless Data Module Specification Sheet

  • 1. Shenzhen KYL Communication Equipment Co., Ltd Shenz Co. KYL-200U Micro Power Wireless Transceiver Data Module Shenzhen KYL Communication Equipment Co., Ltd Address: Unit 5-7, Building3, Huangdu Square, South of Exhibition Center, Yitian Road, Futian District, Shenzhen Guangdong China Tel: +0086-755-83410815 Fax: +0086-755-83408785 Skype Skype:lxmlosia Yahoo messenger: losia2012@yahoo.com MSN: kylcom01.com@hotmail.com E_mail: sales01@rf-data.com /kyl03losia@gmail.com Website: http://www.rf-data.com Fax: +0086-755-83408785 0086- 755-83408785 kyl03losia@gmail.com www.rf-data.com 1
  • 2. Shenzhen KYL Communication Equipment Co., Ltd Shenz Co. Catalogue I. About KYL-200U ....................................................................3 II. Features of KYL-200U ..........................................................3 III. Applications of KYL-200U.................................................. 4 IV. How to use KYL-200U..........................................................4 KYL-200U..........................................................4 V. Networking Application of KYL-200U............................... 14 VI. Technical specification of KYL-200U................................ 14 VII. Description of type.............................................................. 15 Fax: +0086-755-83408785 0086- 755-83408785 kyl03losia@gmail.com www.rf-data.com 2
  • 3. Shenzhen KYL Communication Equipment Co., Ltd Shenz Co. Before using the product please read the use manual carefully. Any question in technical, you can contact us. Tel: +0086-755-83410815. I: About KYL-200U KYL-200U, the micro power wireless transceiver data module is used as the wireless data transceiver in short-ranges, with the small size, weight and power consumption and good stability and reliability. Narrowband low power UHF wireless data transmitters and receivers with channel spacing as low as 25 KHz. II: Features: I. Features of KYL-200U 1. Low power transmission with 10mW, 50~100mW is available if needed. 2. With 433MHz as factory default carrier frequency, but 400-470MHz, 868MHz, 915MHz is available if needed. 3. High anti- interference and Low BER (Bit error Rate) Based on the Gaussian Frequency Shift Keying (GFSK) modulation, the high-efficiency forward error correction channel encoding technology is used to enhance data’s resistance to both transient interference and random interference and the actual bit error rate of 10-5 ~ 10-6 can be achieved when channel bit error rate is 10-2. 4. Long Transmission Distance Within the visible range, when the height of antenna is higher than 2m and The Bit Error Rate (BER) is 10-3, the reliable transmission distances respectively is 1000m @1200bps, and is 600m@9600bps. 5. Transparent data transmission Transparent data interface used in transceivers is for meeting many standard or nonstandard user protocols. Any false data generated in air can be filtrated automatically (What has been received is exactly what has been transmitted). 6. Multi-channels KYL-200U transceivers offer 8 channels, if needed, 16 or 32 channels are available to satisfy various configuration of communication under user’s demand at the same time. 7. 2 ports with three connection methods KYL-200U transceivers provide 2 ports with three connections, ports: a UART interface of TTL level, a non-standard RS-232 port and a non-standard RS-485 port. 8. Big data buffer area With optional interface baud rate: 1200/4800/9600/19200bps and 8N1/8E1/8O1 data format (set by user), the transceiver can transmit unlimited data frames with flexible user program. Note: the RF data rate is only settled down before delivery, please inform our sales when placing your orders. Fax: +0086-755-83408785 0086- 755-83408785 kyl03losia@gmail.com www.rf-data.com 3
  • 4. Shenzhen KYL Communication Equipment Co., Ltd Shenz Co. 9. Intelligent data control and no any extra programs required Even for half duplex communication, no any excessive programs required. All RF system data transmission/reception and other On-the-Fly conversion and control are performed by KYL-200U transceivers automatically. 10. Lower power consumption & Sleep function With +5V power, the receiving current is less than 20mA, the transmitting current is less than 40mA, and the sleeping current is less than 20uA. 11. High reliability, small and light By using monolithic radio-frequency integrated circuit and single-chip MCU, the transceivers have less peripheral circuit s, high reliability, and low failure rate. 12. More options of configurable antennas for user different applications. 13. Watchdog monitor Watchdog monitors the inner function, so it can change the traditional product structure and also improve the reliability of our modules. III: Application of KYL-200U: KYL-200U the micro power wireless transceiver data module is suitable for: * AMR Automatic Meter Reading * Wireless alarm and security systems * Building automation, security, wireless monitoring and control of room equipment, Access Control System; * Wireless data transmission, automatic data collection system; * Radio modem can be used for Sports training & competition; * Wireless dishes ordering; * Wireless POS, PDA wireless smart terminal; * RF modem can be used for Electronic bus station and intelligent traffic; * RF transmitter Wireless electronic display screen and queuing machine; * Wireless telemetry Charging for parking, parking lot; * Wireless modem Automobile inspection and four-wheel orientation; * Wireless sensor Industrial wireless remote control and air conditioning remote controller; * Data communication used for railway, oil field, dock and army. * LED display in thruway and public places * Point to multi-point wireless network, wireless on-the-spot bus and automatic data collection system; IV: How to use the KYL-200U KYL-200U provide RS-232, RS-485 and UART/TTL level interface port for direct connection with PC, RS485 devices, monolithic processors and other UART components kinds of applications. The schematic diagram is shown below: Fax: +0086-755-83408785 0086- 755-83408785 kyl03losia@gmail.com www.rf-data.com 4
  • 5. Shenzhen KYL Communication Equipment Co., Ltd Shenz Co. 1. Power supply The factory default setting is +5V(3.3-3.6V will inform when placing the order).By using better ripple factor, KYL-200U transceivers can also share power supply with other equipment. If possible, a voltage-stabilizing chip with 5V voltage is more recommended as the only power supply than Switch power supply. But if only switch power supply available, the jam by switch pulse to the transceivers should be avoided. In addition, the reliable grounding must be used if there is other device in the system equipment. In case of failing to connect with the ground, it can form its own grounding but must be absolutely separated from the municipal electric supply. 2. Connection Definition with terminal KYL-200U transceivers supply one 9-pin connector (JP1), their definitions and connection methods with terminals are shown in Table 1. Table 1: JP1 Pin Definitions and connection methods Pin No. Signal Name Function Level Connection Remarks with terminal 1 GND Grounding of power supply Ground 2 Vcc Power supply DC 5V 3 RxD/TTL Serial data input to the transceiver TTL TxD 4 TxD/TTL Transmitted data out of the TTL RxD transceiver 5 SGND Signal 6 A (TXD) A of RS-485(TxD of RS-232) A(RxD) 7 B (RXD) B of RS-485(RxD of RS-232) B(TxD) 8 SLEEP Sleep control (input) TTL Sleep signal High level sleep 9 RESET Reset signal(input) TTL Negative pulse reset Fax: +0086-755-83408785 0086- 755-83408785 kyl03losia@gmail.com www.rf-data.com 5
  • 6. Shenzhen KYL Communication Equipment Co., Ltd Shenz Co. 3. The connection schematic diagram between computer and our RF module 4. Setting of channel, interface, and data format Before using KYL-200U, the user needs to make simple configuration based on its own needs to determine the channel,interface mode and data format. The user can change or view the module's interface baud rate, channel and address code. Parameter setting or reading as per the testing software KYLCOM.exe in the PC (in products box).And the configuration is as follows: i. Channel configuration: Channel No. Frequency Channel No. Frequency 1 429.0325MHZ 5 433.0325MHZ 2 430.0325MHZ 6 434.0325MHZ 3 431.0325MHZ 7 435.0325MHZ 4 432.0325MHZ 8 436.0325MHZ Note: the frequency points corresponding to each channel can be adjusted based on the user’s needs. user’ ii. The schematic diagram of setting the parameter as follows: a. Connect the PC and module with RS232 data cable. b. Open the “KYLCOM” PC software, select “English” as follows: Fax: +0086-755-83408785 0086- 755-83408785 kyl03losia@gmail.com www.rf-data.com 6
  • 7. Shenzhen KYL Communication Equipment Co., Ltd Shenz Co. c. Click “open port”, then will open a small window as the following picture, clients will write the parameters in this windows. d. Click “read paras”. “Read correct” show your connection between KYL module and PC is correct. Fax: +0086-755-83408785 0086- 755-83408785 kyl03losia@gmail.com www.rf-data.com 7
  • 8. Shenzhen KYL Communication Equipment Co., Ltd Shenz Co. If you want to change some technical parameter, you need do as follows. e. User can change the parameter such as channel and interface rate and Parity mode according to actual demand through the button of the left window. After writing the parameters in the left catalogue, click the “write para”, then will show “write correct”. So you have finished the process for changing technical parameter. Fax: +0086-755-83408785 0086- 755-83408785 kyl03losia@gmail.com www.rf-data.com 8
  • 9. Shenzhen KYL Communication Equipment Co., Ltd Shenz Co. Note: The RF data rate(Air Rate) can not be set by user, it is confirmed when placing orders and set before delivery. So please confirm the RF data rate when placing the order. 5. Installation dimension: Fax: +0086-755-83408785 0086- 755-83408785 kyl03losia@gmail.com www.rf-data.com 9
  • 10. Shenzhen KYL Communication Equipment Co., Ltd Shenz Co. 6. The Function-indicator light a. The LED indicator light will glitter red for 0.5S once after switched on. b. The LED indicator light will glitter green continually while receiving data from air. c. The LED indicator light will glitter red continuously when transmitting data into air after receiving from COM. d. If the module enables the sleep function, LED indicator light is always dark. 7. Supported protocol and Transmit capability KYL-200U standard transceivers offer transparent protocol to support various applications and protocols of users. If the user needs to decrease his cost or ease the workload of terminal CPU, we can add other specific functions based on the transparent protocol, such as addressing, data acquisition, command interpretation, etc. 8. Sleep function instruction: Due to reducing more consumption, KYL-200U transceivers support Sleep function. In sleep mode, the current consumption is less than 20uA. a. How to use the Sleep function: The Pin8 ‘SLP’ in JP1 is the signal of sleep control. In high power level, transceiver stays in working mode. In low power level (<0.5V), transceiver stays in sleep mode. The SLP signal can convert transceiver from working to sleep mode in 1ms after falling edge. If the Sleep signal arrives when the transceiver is transmitting data, the module will enter sleep mode after finishing transmission. From sleep mode to working, it takes the transceiver 1ms after rising edge. To disable the opened sleep function of KYL-200U, the SLP (SLEEP) pin should be definitely connected with 0 or ground. b. Attentions about use of sleep function: When the sleep function enabled, any supply glitches, such as switch dithering, Fax: +0086-755-83408785 0086- 755-83408785 kyl03losia@gmail.com www.rf-data.com 10
  • 11. Shenzhen KYL Communication Equipment Co., Ltd Shenz Co. fire striking or quick switching on and off, could cause the transceiver to be switched to the wrong sleep mode. After switching on, users can avoid this error by making a compulsive restoration once after the CPU delays 100ms. Sleep Timing Diagram: 9. The attentions of data transmission a. The delay time (tc) of conversion between transmitting and receiving is less than 1ms. Timing diagram: b. The delay time of transceivers between the first bit sent by TxD to the first bit received by RxD. Due to a data processing will be made on user’s data by KYL-200U transceiver using FEC (Forward Error Correction) or other correction algorithm, when RxD of a KYL-200U transceiver ‘A’ receives the data, then transmits it, the other one transceiver ‘B’ will have a delay (ts) to receive and transmit by TxD. Different RF data rate causes different delay time. Please see the specific delay time below: Fax: +0086-755-83408785 0086- 755-83408785 kyl03losia@gmail.com www.rf-data.com 11
  • 12. Shenzhen KYL Communication Equipment Co., Ltd Shenz Co. RF Date Rate Delay RF Date Rate Delay (bps) Ts(mS) (bps) Ts(mS) 1200 90 9600 16 2400 48 19200 10 4800 30 Timing diagram: c. Error dealing procedure: To enhance the reliability and stability of user’s systems, a verify bit or a Cyclic Redundancy Check (CRC) mode is highly recommended to resent the wrong information while using KYL-200U modules. d. Large-number data transmission In theory, when the interface data rate is faster than the RF data rate, KYL-200U transceivers can sent unlimited-long data package, but any long packages more than 120B are not recommended. The length of each package should be between 60~100B. We also recommend user to resent the wrong information using Automatic Error Request Equipment (ARQ). The analyzing as below: What if the actual transmission BER (Bit Error Rate) is 10-4, 1 packet with 1KB data, which is about 10-thousand bits, is sent, theoretically, at least 1 bit will be received wrongly, then the 1KB information will never be received correctly. But if we package the data into 10 packets with 100B for each, when all 10 packets are sent, there will be only 1 packet wrong according to this probability. After that, resend this wrong packet using ARQ mode. So by resending one more packet and the efficiency rate is reduced 10%, all data will be absolutely received correctly. 10. Antenna configuration: Many appropriative antennas for low power RF modules are selected for meeting different user antenna configurations. Please ask our Sales office for further Fax: +0086-755-83408785 0086- 755-83408785 kyl03losia@gmail.com www.rf-data.com 12
  • 13. Shenzhen KYL Communication Equipment Co., Ltd Shenz Co. information about the antenna’s dimension and performance. a. Helical SMA antennas KYL-ANT-433-10-SMA: 100mm helical SMA antennas with high gain and low cost, reach a long distance. KYL-ANT-433-3-SMA: 28mm SMA helical antenna with magnetic core, small size, beautiful appearance (like the mobile phone antenna) KYL-ANT-433-10-ZSMA: 100mm SMA helical antenna with folding joint, easy for adjusting the direction and fixing. b. Magnetic vehicle antenna KYL-ANT-O433S-300H1.5-SMA: include magnetic antenna base, suitable for equipment with metal shell, easy for fixing, effective to enhance the transmission distance. More kinds of antenna, please browse our website: http://www.rf-data.com/Products_list_en.asp?classid=163 If the user has special demands on antennas, we can design and produce for them specially. V. Networking Application of KYL-200U The communication channel of KYL-200U is half duplex, which is most suitable for the communication mode of point to multi-point. Under this mode, one master station must be set, and all of the rest are slave stations. A unique address Fax: +0086-755-83408785 0086- 755-83408785 kyl03losia@gmail.com www.rf-data.com 13
  • 14. Shenzhen KYL Communication Equipment Co., Ltd Shenz Co. is given to each station. The coordination of communication is controlled by master station that uses data frames containing address code to transmit data or command. Slave station will receive all of the data and command and compare the received address code with local address code. If they are different, the data will be deserted without any response. If those address codes are the same, it means the data is sent to the local. Slave station will make different responses according to the transmitted data or command and send back the data of response. All these jobs must be performed by upper protocol, and it is assured that there is only one transmitter-receiver in the state of transmission in the communication network at any instant moment so as to avoid the cross-interference. KYL-200U can also be used for point-to-point communication with easier operation. For the programming of serial port, all you have to do is to remember that its communication mode is semi duplex while always observing the time sequence of come-and-go for receiving and transmitting. VI. Technical specification of KYL-200U * Modulation mode: GFSK/FSK * Working frequency: 400MHz~470MHz, 868MHz, 915MHz; * Power supply: DC 5V (3.3~3.6V informed when placing the order); * RF power: ≤10mW, 50mW~100mW is available; * RF data rate: 1200/2400/4800/9600/19200bps (Set before delivery); * Receive current: <20mA (TTL connect); * Receive sensitivity: -120dBm (1200bps); -115dBm (9600bps); * Transmitting current: <40mA; * Sleep current: <20uA; * Interface data format: 8E1/8N1/8O1; * Working humidity: 10%~90% relative humidity without condensation; * Working temperature: -35℃~+75℃( industrial) * RF Line-of-sight Range: 600m(BER=10-5@9600bps); 1000m(BER=10-5@1200bps); * Size: 47mm*26mm*10mm (without antenna port). Fax: +0086-755-83408785 0086- 755-83408785 kyl03losia@gmail.com www.rf-data.com 14
  • 15. Shenzhen KYL Communication Equipment Co., Ltd Shenz Co. VII. Description of type KYL-200U-96 Baud Rate 12:1200bps manufacturer type 24:2400bps 48:4800bps 96:9600bps 192:19200bps Fax: +0086-755-83408785 0086- 755-83408785 kyl03losia@gmail.com www.rf-data.com 15