This 7-page test report summarizes waterproof and drop tests performed on a waterproof iPhone 6 case submitted by Dongguan Yuanguan Plastic & Mold Co., Ltd. Two tests were conducted: an IPX8 waterproof test by submerging the case 3 meters deep for 3 hours with no water ingress, and a drop test from 3 meters onto concrete with the case showing no visible damage after 10 drops. Both tests were passed based on the client's requirements. The report provides detailed test methods, conditions, results and photos documenting the testing process and outcomes.
iMovR Lander Lite - ANSI/BIFMA X5.5-2014 Certification
IP-X8 SGS test report for YG water-proof iPhone 6 case.PDF
1. TEST REPORT
No. : GZIN1506025688PS
Date : Jul 01, 2015
Page: 1 of 7
CUSTOMER NAME: DONGGUAN YUANGUAN PLASTIC & MOLD CO.,LTD.
ADDRESS: #3,HAIBIN RD,6TH INDUSTRIL AVE,WUSHA. CHANGAN DONGGUAN
GUANGDONG
The following sample(s) was/ were submitted and identified on behalf of the client as:
Sample Name : WATER-PROOF FOR IPHONE6 CASE
SGS Ref. No. : GZIN1506026247MR, GZIN1506026077MR
Date of Receipt : Jun 24, 2015
Testing Start Date : Jun 24, 2015
Testing End Date : Jul 01, 2015
Test result(s) : For further details, please refer to the following page(s)
Signed for
SGS-CSTC Standards Technical
Services Co., Ltd. GZ Branch Testing
Center
Eleain Fan
Authorized signatory
2. TEST REPORT
No. : GZIN1506025688PS
Date : Jul 01, 2015
Page: 2 of 7
Summary of Results:
No. Test Item Test Method Result Conclusion
1 IPX8
MIL-STD-810G-2008, CHG.1-2014
Method 512.6 and client’
requirement
No ingress of
water.
Pass
2 Drop Test Provided by client
No visible
damage
Pass
Pass : Meet the requirements;
Fail : Does not meet the requirements;
Note:
/ : Not Apply to the judgment.
Original Sample Photo:
Before test-Front Before test-Rear
3. TEST REPORT
No. : GZIN1506025688PS
Date : Jul 01, 2015
Page: 3 of 7
1.Test Item: IPX8
Sample Description: See photo
Test Method: MIL-STD-810G-2008, CHG.1-2014 Method 512.6 and client’ requirement
Test Condition:
Depth: 3 m
Test duration: 3 h
Test Result:
Sample Result Client’s requirement Conclusion
1 No ingress of water. No ingress of water. Pass
Test Photo:
After test-Front After test-Rear
After test-Front-Local part After test-Front-Local part
4. TEST REPORT
No. : GZIN1506025688PS
Date : Jul 01, 2015
Page: 4 of 7
During Test
Equipment Information:
Equipment Model Equipment No. Calibration date
Next Calibration
date
Waterproof X8 GZMR-RL-E094 2014-09-10 2015-09-09
2. Test Item: Drop Test
Sample Description: See photo
Test Method: Provided by client
Test Condition:
Drop Height: 3 m
Drop Plane: Concrete plate
Drop Times: 4 corners, 6 faces, total 10 drops
Lab Environment Condition: 15℃~35℃, 25%RH~75%RH
Test Result:
Sample Result Client’s requirement Conclusion
1 No visible damage No visible damage Pass
5. TEST REPORT
No. : GZIN1506025688PS
Date : Jul 01, 2015
Page: 5 of 7
Test Photo:
After test During test-Drop 1
During test-Drop 2 During test-Drop 3
6. TEST REPORT
No. : GZIN1506025688PS
Date : Jul 01, 2015
Page: 6 of 7
During test-Drop 4 During test-Drop 5
During test-Drop 6 During test-Drop 7
During test-Drop 8 During test-Drop 9
7. TEST REPORT
No. : GZIN1506025688PS
Date : Jul 01, 2015
Page: 7 of 7
During test-Drop 10 During test
******** End of report********