2. REPORT FOR THERMOGENESIS GROUP, INC.
Report No.: 104048831GRR-001
Date: 11-Sep-2019
P.O.: 55338
4700 Broadmoor Ave SE, Suite 200
Kentwood, MI 49512
Telephone: +1 616 656 7401
Facsimile: +1 616 656 2022
www.intertek.com
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek
and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek
assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense
or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this
report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement
of the tested material, product or service must first be approved in writing by Intertek. The observations and test
results in this report are relevant only to the sample tested. This report by itself does not imply that the material,
product, or service is or has ever been under an Intertek certification program.
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 2 of 22
SECTION 1
CLIENT INFORMATION
Attention: Ron Wiener
Thermogenesis Group, Inc.
14260 NE 21st Street
Bellevue, WA 98007
USA
Phone: (206) 905-9435
Email: ron@imovr.com
James Jantz Dorian Bako
Test Engineer Project Reviewer
3. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 3 of 22
SECTION 2
SUMMARY AND CONCLUSION
Date Received: 29-Aug-2019
Dates Tested: 03-Sep-2019 to 11-Sep-2019
DESCRIPTION OF SAMPLES AS RECEIVED
Part Description: Lander Lite Standing Desk with Lander Lite 30” x 41” Desktop
& Lander Lite 30” x 71” Desktop
Condition of Samples: Production
Number of Samples Received: Two (2)
SAMPLE ID PART NO. DESCRIPTION
1 Z-LN3B-REA3041NC
Lander Lite 30” x 41”
Desk Top
2 LN-REA3071BW
Lander Lite 30” x 71”
Desk Top
The Lander Lite Standing Desk was used as the base for both Desk Tops listed above.
WORK REQUESTED/APPLICABLE DOCUMENTS
ANSI/BIFMA X5.5-2014 DESK/TABLE PRODUCTS
Intertek quote Qu-00996322
CONCLUSION
SAMPLE ID ANSI/BIFMA X5.5-2014 DESK/TABLE PRODUCTS RESULTS
1 4.3 Stability Under Vertical Load Test CONFORMING
2 4.3 Stability Under Vertical Load Test CONFORMING
2 5.2 Concentrated Functional Load Test CONFORMING
2 5.3 Distributed Functional Load Test CONFORMING
2 5.4 Concentrated Proof Load Test CONFORMING
2 5.5 Distributed Proof Load Test CONFORMING
2 6. Top Load Ease Cycle Test CONFORMING
2 7. Desk/Table Unit Drop Test CONFORMING
2 8. Leg Strength Test CONFORMING
2 15. Work Surface Vertical Adjustment Test CONFORMING
SAMPLE DISPOSITION
The samples were returned to client upon test completion.
4. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 4 of 22
TEST EQUIPMENT:
ASSET ID DESCRIPTION CAL DATE CAL DUE
138012 Scale/0-1,000# 10/15/2018 10/15/2019
138039.10 WEIGHT BAG VBU VBU
138238 CONTROLLER CBU CBU
138394 0 to 1000lb Load Cell 8/21/2019 8/21/2020
138397 Portable Vertical Loading Test Stand VBU VBU
138500.10 Stopwatch 10/02/2018 10/02/2019
138519 48" STRAIGHT-EDGE 12/17/2018 12/17/2019
5. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 5 of 22
SECTION 3
4.3 STABILITY UNDER VERTICAL LOAD TEST:
Date Received: 29-Aug-2019
Date Tested: 03-Sep-2019 to 11-Sep-2019
Location Tested: Intertek Kentwood, MI
DESCRIPTION OF SAMPLES:
Part Description: Lander Lite Standing Desk with Lander Lite 30” x 41” Desktop
& Lander Lite 30” x 71” Desktop
Number of Samples Tested: Two (2)
TEST PROCEDURE:
Test Method: Per ANSI/BIFMA X5.5-2014 Test No. 4.3:
The unit shall be levelled. Placement of the load shall be on a 12” diameter disk 1” from the edge at the
least stable position.
Top Load: 125 lbs.
ACCEPTANCE CRITERIA:
Per ANSI/BIFMA X5.5-2014 Test No. 4.3:
The unit shall not tip over.
RESULTS:
SAMPLE ID STATIC LOAD RESULTS
1 125 lbs. Conforming
2 125 lbs. Conforming
The submitted samples met the acceptance criteria of the test described above. Refer to the
following pages for photographs.
6. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 6 of 22
Stability Under Vertical Load Test –30” x 41” Desktop – Sample 1
7. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 7 of 22
Stability Under Vertical Load Test – Sample 2
8. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 8 of 22
5.2 – 5.5 UNIT STRENGTH TESTS:
Date Received: 29-Aug-2019
Date Tested: 03-Sep-2019
Location Tested: Intertek Kentwood, MI
DESCRIPTION OF SAMPLES:
Part Description: Lander Lite Standing Desk with Lander Lite 30” x 71” Desktop
Number of Samples Tested: One (1)
TEST PROCEDURE:
Test Method: Per ANSI/BIFMA X5.5-2014 Test Nos. 5.2 – 5.5:
ACCEPTANCE CRITERIA:
Per ANSI/BIFMA X5.5-2014 Test Nos. 5.2 – 5.5:
Functional Load: There shall be no loss of serviceability.
Proof Load: There shall be no major change in the structural
integrity.
RESULTS:
SAMPLE ID
SURFACE TO BE TESTED
(CLASS)
WORK SURFACE RESULTS
2
Surface Size 202”
Concentrated Loads
Functional: 200 lbs. Conforming
Proof: 300 lbs. Conforming
Distributed Loads
Functional: 303 lbs. Conforming
Proof: 465 lbs. Conforming
The submitted sample met the acceptance level criteria of the test described above. Refer to the
following pages for photographs.
9. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 9 of 22
Concentrated Functional Load Test – Sample 2
10. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 10 of 22
Concentrated Proof Load Test – Sample 2
11. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 11 of 22
Distributed Functional Load Test – Sample 2
12. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 12 of 22
Distributed Proof Load Test – Sample 2
13. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 13 of 22
6. TOP LOAD EASE CYCLE TEST:
Date Received: 29-Aug-2019
Date Tested: 10-Sep-2019 to 11-Sep-2019
Location Tested: Intertek Kentwood, MI
DESCRIPTION OF SAMPLES:
Part Description: Lander Lite Standing Desk with Lander Lite 30” x 71” Desktop
Number of Samples Tested: One (1)
TEST PROCEDURE:
Test Method: Per ANSI/BIFMA X5.5-2014 Test No. 6:
Number of Cycles: 10,000
Load: 200 lbs.
Cycles Per Minute: 14 ± 6
Load Drawers with: 0.017 lbs./cu. in.
Load Area: 16” Diameter
ACCEPTANCE CRITERIA:
Per ANSI/BIFMA X5.5-2014 Test No. 6:
There shall be no loss of serviceability to the unit. A pull force to overcome anti-rebound or
interlock and to fully extend the drawer shall not exceed 11.2 lbs.
RESULTS:
SAMPLE ID NUMBER OF CYCLES RESULTS
2 10,000 Conforming
The submitted sample met the acceptance level criteria of the test described above. Refer to the
following page for photograph.
14. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 14 of 22
Top Load Ease Cycle Test – Sample 2
15. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 15 of 22
7. DESK/TABLE UNIT DROP TEST:
Date Received: 29-Aug-2019
Date Tested: 11-Sep-2019
Location Tested: Intertek Kentwood, MI
DESCRIPTION OF SAMPLES:
Part Description: Lander Lite Standing Desk with Lander Lite 30” x 71” Desktop
Number of Samples Tested: One (1)
TEST PROCEDURE:
Test Method: Per ANSI/BIFMA X5.5-2014 Test No. 7:
NOTE: Test applies to freestanding Category 1 Desk or Tables that are less than 72” in length. Test
does not apply to units with casters or keyboard tables.
Set all adjustable features at midpoint.
UNIT WEIGHT DROP HEIGHT
<45 kg (100 lbs.) 180 mm (7.1 in.)
45 – 90 kg (100-200 lbs.) 120 mm (4.7 in.)
>90 – 136kg (200-300 lbs.) 60 mm (2.4 in.)
>136 kg (300 lbs.) N/A
Unit Weight: 102 lbs.
ACCEPTANCE CRITERIA:
Per ANSI/BIFMA X5.5-2014 Test No. 7:
There shall be no loss of serviceability.
RESULTS:
SAMPLE ID DROP HEIGHT RESULTS
2 4.7” Conforming
The submitted sample met the acceptance criteria of the test described above. Refer to the
following page for photograph.
16. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 16 of 22
Desk/Table Unit Drop Test – Sample 2
17. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 17 of 22
8. LEG STRENGTH TEST:
Date Received: 29-Aug-2019
Date Tested: 11-Sep-2019
Location Tested: Intertek Kentwood, MI
DESCRIPTION OF SAMPLES:
Part Description: Lander Lite Standing Desk with Lander Lite 30” x 71” Desktop
Number of Samples Tested: One (1)
TEST PROCEDURE:
Test Method: Per ANSI/BIFMA X5.5-2014 Test No. 8:
Unit Weight: 102 lbs.
NOTE: Based on the desk or table category, calculate functional and proof loads.
ACCEPTANCE CRITERIA:
Per ANSI/BIFMA X5.5-2014 test no. 8:
Functional Force: There shall be no loss of serviceability.
Proof Force: There shall be no sudden and major change in the
structural integrity of the product. Loss of
serviceability is acceptable.
RESULTS:
SAMPLE ID SURFACE TO BE TESTED (CLASS) RESULTS
2
Functional Force
Inward on Leg: 100 lbf. Conforming
Outward on Leg: 50 lbf. Conforming
Proof Force:
Inward on Leg: 150 lbf. Conforming
Outward on Leg: 75 lbf. Conforming
The submitted sample met the acceptance level criteria of the test described above. Refer to the
following pages for photographs.
18. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 18 of 22
Leg Strength Test – Functional – Sample 2
19. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 19 of 22
Leg Strength Test – Proof – Sample 2
20. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 20 of 22
15. WORK SURFACE VERTICAL ADJUSTMENT TEST:
Date Received: 29-Aug-2019
Date Tested: 03-Sep-2019 to 08-Sep-2019
Location Tested: Intertek Kentwood, MI
DESCRIPTION OF SAMPLES:
Part Description: Lander Lite Standing Desk with Lander Lite 30” x 71”
Desktop
Number of Samples Tested: One (1)
TEST PROCEDURE:
Test Method: Per ANSI/BIFMA X5.5-2014 Test No. 15:
Number of Cycles: 1,000 in each quartile.
Load: 100 lbs.
Cycle Rate: Recommended by manufacturer or six (6) cycles per
minute.
ACCEPTANCE CRITERIA:
Per ANSI/BIFMA 5.5-2014 Test No. 15:
There shall be no loss of serviceability. For tables with crank driven adjustment mechanisms, the
operating force on the handle to adjust the table shall not exceed 11.2 lbf.
RESULTS:
SAMPLE ID QUARTILE RESULTS
2
1 Conforming
2 Conforming
3 Conforming
4 Conforming
The submitted sample met the acceptance level criteria of the test described above. Refer to the
following page for photograph.
21. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 21 of 22
Work Surface Vertical Adjustment Test – Sample 2
22. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 22 of 22
SECTION 4
REVISIONS MADE TO TEST REPORT
DATE REVISION DESCRIPTION REVISED BY REVISED BY
11-Sep-2019 Initial release. James Jantz