SlideShare a Scribd company logo
1 of 22
Download to read offline
THERMOGENESIS
GROUP, INC.
TEST REPORT
SCOPE OF WORK
ANSI/BIFMA X5.5-2014 DESK/TABLE PRODUCTS testing on Lander Lite Standing Desk with Lander
Lite 30” x 41” Desktop & Lander Lite 30” x 71” Desktop
REPORT NUMBER
104048831GRR-001
ISSUE DATE
11-Sep-2019
PAGES
22
DOCUMENT CONTROL NUMBER
RT-AMER-L-GRR-DUR-001
© 2019 INTERTEK
REPORT FOR THERMOGENESIS GROUP, INC.
Report No.: 104048831GRR-001
Date: 11-Sep-2019
P.O.: 55338
4700 Broadmoor Ave SE, Suite 200
Kentwood, MI 49512
Telephone: +1 616 656 7401
Facsimile: +1 616 656 2022
www.intertek.com
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek
and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek
assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense
or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this
report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement
of the tested material, product or service must first be approved in writing by Intertek. The observations and test
results in this report are relevant only to the sample tested. This report by itself does not imply that the material,
product, or service is or has ever been under an Intertek certification program.
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 2 of 22
SECTION 1
CLIENT INFORMATION
Attention: Ron Wiener
Thermogenesis Group, Inc.
14260 NE 21st Street
Bellevue, WA 98007
USA
Phone: (206) 905-9435
Email: ron@imovr.com
James Jantz Dorian Bako
Test Engineer Project Reviewer
TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 3 of 22
SECTION 2
SUMMARY AND CONCLUSION
Date Received: 29-Aug-2019
Dates Tested: 03-Sep-2019 to 11-Sep-2019
DESCRIPTION OF SAMPLES AS RECEIVED
Part Description: Lander Lite Standing Desk with Lander Lite 30” x 41” Desktop
& Lander Lite 30” x 71” Desktop
Condition of Samples: Production
Number of Samples Received: Two (2)
SAMPLE ID PART NO. DESCRIPTION
1 Z-LN3B-REA3041NC
Lander Lite 30” x 41”
Desk Top
2 LN-REA3071BW
Lander Lite 30” x 71”
Desk Top
The Lander Lite Standing Desk was used as the base for both Desk Tops listed above.
WORK REQUESTED/APPLICABLE DOCUMENTS
ANSI/BIFMA X5.5-2014 DESK/TABLE PRODUCTS
Intertek quote Qu-00996322
CONCLUSION
SAMPLE ID ANSI/BIFMA X5.5-2014 DESK/TABLE PRODUCTS RESULTS
1 4.3 Stability Under Vertical Load Test CONFORMING
2 4.3 Stability Under Vertical Load Test CONFORMING
2 5.2 Concentrated Functional Load Test CONFORMING
2 5.3 Distributed Functional Load Test CONFORMING
2 5.4 Concentrated Proof Load Test CONFORMING
2 5.5 Distributed Proof Load Test CONFORMING
2 6. Top Load Ease Cycle Test CONFORMING
2 7. Desk/Table Unit Drop Test CONFORMING
2 8. Leg Strength Test CONFORMING
2 15. Work Surface Vertical Adjustment Test CONFORMING
SAMPLE DISPOSITION
The samples were returned to client upon test completion.
TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 4 of 22
TEST EQUIPMENT:
ASSET ID DESCRIPTION CAL DATE CAL DUE
138012 Scale/0-1,000# 10/15/2018 10/15/2019
138039.10 WEIGHT BAG VBU VBU
138238 CONTROLLER CBU CBU
138394 0 to 1000lb Load Cell 8/21/2019 8/21/2020
138397 Portable Vertical Loading Test Stand VBU VBU
138500.10 Stopwatch 10/02/2018 10/02/2019
138519 48" STRAIGHT-EDGE 12/17/2018 12/17/2019
TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 5 of 22
SECTION 3
4.3 STABILITY UNDER VERTICAL LOAD TEST:
Date Received: 29-Aug-2019
Date Tested: 03-Sep-2019 to 11-Sep-2019
Location Tested: Intertek Kentwood, MI
DESCRIPTION OF SAMPLES:
Part Description: Lander Lite Standing Desk with Lander Lite 30” x 41” Desktop
& Lander Lite 30” x 71” Desktop
Number of Samples Tested: Two (2)
TEST PROCEDURE:
Test Method: Per ANSI/BIFMA X5.5-2014 Test No. 4.3:
The unit shall be levelled. Placement of the load shall be on a 12” diameter disk 1” from the edge at the
least stable position.
Top Load: 125 lbs.
ACCEPTANCE CRITERIA:
Per ANSI/BIFMA X5.5-2014 Test No. 4.3:
The unit shall not tip over.
RESULTS:
SAMPLE ID STATIC LOAD RESULTS
1 125 lbs. Conforming
2 125 lbs. Conforming
The submitted samples met the acceptance criteria of the test described above. Refer to the
following pages for photographs.
TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 6 of 22
Stability Under Vertical Load Test –30” x 41” Desktop – Sample 1
TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 7 of 22
Stability Under Vertical Load Test – Sample 2
TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 8 of 22
5.2 – 5.5 UNIT STRENGTH TESTS:
Date Received: 29-Aug-2019
Date Tested: 03-Sep-2019
Location Tested: Intertek Kentwood, MI
DESCRIPTION OF SAMPLES:
Part Description: Lander Lite Standing Desk with Lander Lite 30” x 71” Desktop
Number of Samples Tested: One (1)
TEST PROCEDURE:
Test Method: Per ANSI/BIFMA X5.5-2014 Test Nos. 5.2 – 5.5:
ACCEPTANCE CRITERIA:
Per ANSI/BIFMA X5.5-2014 Test Nos. 5.2 – 5.5:
Functional Load: There shall be no loss of serviceability.
Proof Load: There shall be no major change in the structural
integrity.
RESULTS:
SAMPLE ID
SURFACE TO BE TESTED
(CLASS)
WORK SURFACE RESULTS
2
Surface Size 202”
Concentrated Loads
Functional: 200 lbs. Conforming
Proof: 300 lbs. Conforming
Distributed Loads
Functional: 303 lbs. Conforming
Proof: 465 lbs. Conforming
The submitted sample met the acceptance level criteria of the test described above. Refer to the
following pages for photographs.
TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 9 of 22
Concentrated Functional Load Test – Sample 2
TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 10 of 22
Concentrated Proof Load Test – Sample 2
TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 11 of 22
Distributed Functional Load Test – Sample 2
TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 12 of 22
Distributed Proof Load Test – Sample 2
TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 13 of 22
6. TOP LOAD EASE CYCLE TEST:
Date Received: 29-Aug-2019
Date Tested: 10-Sep-2019 to 11-Sep-2019
Location Tested: Intertek Kentwood, MI
DESCRIPTION OF SAMPLES:
Part Description: Lander Lite Standing Desk with Lander Lite 30” x 71” Desktop
Number of Samples Tested: One (1)
TEST PROCEDURE:
Test Method: Per ANSI/BIFMA X5.5-2014 Test No. 6:
Number of Cycles: 10,000
Load: 200 lbs.
Cycles Per Minute: 14 ± 6
Load Drawers with: 0.017 lbs./cu. in.
Load Area: 16” Diameter
ACCEPTANCE CRITERIA:
Per ANSI/BIFMA X5.5-2014 Test No. 6:
There shall be no loss of serviceability to the unit. A pull force to overcome anti-rebound or
interlock and to fully extend the drawer shall not exceed 11.2 lbs.
RESULTS:
SAMPLE ID NUMBER OF CYCLES RESULTS
2 10,000 Conforming
The submitted sample met the acceptance level criteria of the test described above. Refer to the
following page for photograph.
TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 14 of 22
Top Load Ease Cycle Test – Sample 2
TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 15 of 22
7. DESK/TABLE UNIT DROP TEST:
Date Received: 29-Aug-2019
Date Tested: 11-Sep-2019
Location Tested: Intertek Kentwood, MI
DESCRIPTION OF SAMPLES:
Part Description: Lander Lite Standing Desk with Lander Lite 30” x 71” Desktop
Number of Samples Tested: One (1)
TEST PROCEDURE:
Test Method: Per ANSI/BIFMA X5.5-2014 Test No. 7:
NOTE: Test applies to freestanding Category 1 Desk or Tables that are less than 72” in length. Test
does not apply to units with casters or keyboard tables.
Set all adjustable features at midpoint.
UNIT WEIGHT DROP HEIGHT
<45 kg (100 lbs.) 180 mm (7.1 in.)
45 – 90 kg (100-200 lbs.) 120 mm (4.7 in.)
>90 – 136kg (200-300 lbs.) 60 mm (2.4 in.)
>136 kg (300 lbs.) N/A
Unit Weight: 102 lbs.
ACCEPTANCE CRITERIA:
Per ANSI/BIFMA X5.5-2014 Test No. 7:
There shall be no loss of serviceability.
RESULTS:
SAMPLE ID DROP HEIGHT RESULTS
2 4.7” Conforming
The submitted sample met the acceptance criteria of the test described above. Refer to the
following page for photograph.
TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 16 of 22
Desk/Table Unit Drop Test – Sample 2
TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 17 of 22
8. LEG STRENGTH TEST:
Date Received: 29-Aug-2019
Date Tested: 11-Sep-2019
Location Tested: Intertek Kentwood, MI
DESCRIPTION OF SAMPLES:
Part Description: Lander Lite Standing Desk with Lander Lite 30” x 71” Desktop
Number of Samples Tested: One (1)
TEST PROCEDURE:
Test Method: Per ANSI/BIFMA X5.5-2014 Test No. 8:
Unit Weight: 102 lbs.
NOTE: Based on the desk or table category, calculate functional and proof loads.
ACCEPTANCE CRITERIA:
Per ANSI/BIFMA X5.5-2014 test no. 8:
Functional Force: There shall be no loss of serviceability.
Proof Force: There shall be no sudden and major change in the
structural integrity of the product. Loss of
serviceability is acceptable.
RESULTS:
SAMPLE ID SURFACE TO BE TESTED (CLASS) RESULTS
2
Functional Force
Inward on Leg: 100 lbf. Conforming
Outward on Leg: 50 lbf. Conforming
Proof Force:
Inward on Leg: 150 lbf. Conforming
Outward on Leg: 75 lbf. Conforming
The submitted sample met the acceptance level criteria of the test described above. Refer to the
following pages for photographs.
TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 18 of 22
Leg Strength Test – Functional – Sample 2
TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 19 of 22
Leg Strength Test – Proof – Sample 2
TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 20 of 22
15. WORK SURFACE VERTICAL ADJUSTMENT TEST:
Date Received: 29-Aug-2019
Date Tested: 03-Sep-2019 to 08-Sep-2019
Location Tested: Intertek Kentwood, MI
DESCRIPTION OF SAMPLES:
Part Description: Lander Lite Standing Desk with Lander Lite 30” x 71”
Desktop
Number of Samples Tested: One (1)
TEST PROCEDURE:
Test Method: Per ANSI/BIFMA X5.5-2014 Test No. 15:
Number of Cycles: 1,000 in each quartile.
Load: 100 lbs.
Cycle Rate: Recommended by manufacturer or six (6) cycles per
minute.
ACCEPTANCE CRITERIA:
Per ANSI/BIFMA 5.5-2014 Test No. 15:
There shall be no loss of serviceability. For tables with crank driven adjustment mechanisms, the
operating force on the handle to adjust the table shall not exceed 11.2 lbf.
RESULTS:
SAMPLE ID QUARTILE RESULTS
2
1 Conforming
2 Conforming
3 Conforming
4 Conforming
The submitted sample met the acceptance level criteria of the test described above. Refer to the
following page for photograph.
TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 21 of 22
Work Surface Vertical Adjustment Test – Sample 2
TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001
Date: 11-Sep-2019 P.O.: 55338
Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 22 of 22
SECTION 4
REVISIONS MADE TO TEST REPORT
DATE REVISION DESCRIPTION REVISED BY REVISED BY
11-Sep-2019 Initial release. James Jantz

More Related Content

What's hot

Calculation sheet-for-slab q-2053-01
Calculation sheet-for-slab q-2053-01Calculation sheet-for-slab q-2053-01
Calculation sheet-for-slab q-2053-01Ahmed Gaafar
 
Plem Plet, Plem Plet Oilfield Equipments - WOM Group
Plem Plet, Plem Plet Oilfield Equipments - WOM GroupPlem Plet, Plem Plet Oilfield Equipments - WOM Group
Plem Plet, Plem Plet Oilfield Equipments - WOM Groupwomgroup
 
Basic load out methodologies introduction
Basic load out methodologies introductionBasic load out methodologies introduction
Basic load out methodologies introductionBruce nguyen
 
Ensayo de fuerza_y_control._norma_uneen_124_copy1
Ensayo de fuerza_y_control._norma_uneen_124_copy1Ensayo de fuerza_y_control._norma_uneen_124_copy1
Ensayo de fuerza_y_control._norma_uneen_124_copy1Marcelo Aires
 
Level 3 assessment as per api 579 1 asme ffs-1 for pressure vessel general me...
Level 3 assessment as per api 579 1 asme ffs-1 for pressure vessel general me...Level 3 assessment as per api 579 1 asme ffs-1 for pressure vessel general me...
Level 3 assessment as per api 579 1 asme ffs-1 for pressure vessel general me...Kingston Rivington
 
Bs en 13889 2003(forged steel shackles for general use - gra
Bs en 13889 2003(forged steel shackles for general use - graBs en 13889 2003(forged steel shackles for general use - gra
Bs en 13889 2003(forged steel shackles for general use - graAtef1982
 

What's hot (8)

Derrick manual
Derrick manualDerrick manual
Derrick manual
 
Calculation sheet-for-slab q-2053-01
Calculation sheet-for-slab q-2053-01Calculation sheet-for-slab q-2053-01
Calculation sheet-for-slab q-2053-01
 
Plem Plet, Plem Plet Oilfield Equipments - WOM Group
Plem Plet, Plem Plet Oilfield Equipments - WOM GroupPlem Plet, Plem Plet Oilfield Equipments - WOM Group
Plem Plet, Plem Plet Oilfield Equipments - WOM Group
 
Basic load out methodologies introduction
Basic load out methodologies introductionBasic load out methodologies introduction
Basic load out methodologies introduction
 
Ensayo de fuerza_y_control._norma_uneen_124_copy1
Ensayo de fuerza_y_control._norma_uneen_124_copy1Ensayo de fuerza_y_control._norma_uneen_124_copy1
Ensayo de fuerza_y_control._norma_uneen_124_copy1
 
Level 3 assessment as per api 579 1 asme ffs-1 for pressure vessel general me...
Level 3 assessment as per api 579 1 asme ffs-1 for pressure vessel general me...Level 3 assessment as per api 579 1 asme ffs-1 for pressure vessel general me...
Level 3 assessment as per api 579 1 asme ffs-1 for pressure vessel general me...
 
Bs en 13889 2003(forged steel shackles for general use - gra
Bs en 13889 2003(forged steel shackles for general use - graBs en 13889 2003(forged steel shackles for general use - gra
Bs en 13889 2003(forged steel shackles for general use - gra
 
API 653 TANK INSPECTION.pdf
API 653 TANK INSPECTION.pdfAPI 653 TANK INSPECTION.pdf
API 653 TANK INSPECTION.pdf
 

Similar to iMovR Lander Lite - ANSI/BIFMA X5.5-2014 Certification

ANSI/BIFMA Certification for iMovR Lander Desk - 41"
ANSI/BIFMA Certification for iMovR Lander Desk - 41"ANSI/BIFMA Certification for iMovR Lander Desk - 41"
ANSI/BIFMA Certification for iMovR Lander Desk - 41"iMovR
 
Engineering Science WorksheetsTENSILE TESTER KIT ES6TE.docx
Engineering Science WorksheetsTENSILE TESTER KIT ES6TE.docxEngineering Science WorksheetsTENSILE TESTER KIT ES6TE.docx
Engineering Science WorksheetsTENSILE TESTER KIT ES6TE.docxSALU18
 
IRJET- Design and Analysis of Pressure Vessel using Software
IRJET- Design and Analysis of Pressure Vessel using SoftwareIRJET- Design and Analysis of Pressure Vessel using Software
IRJET- Design and Analysis of Pressure Vessel using SoftwareIRJET Journal
 
IRJET- Assessment of Mechanical Properties of Bamboo and its Compatibilty...
IRJET-  	  Assessment of Mechanical Properties of Bamboo and its Compatibilty...IRJET-  	  Assessment of Mechanical Properties of Bamboo and its Compatibilty...
IRJET- Assessment of Mechanical Properties of Bamboo and its Compatibilty...IRJET Journal
 
VantemTest Report 4x19x12 w sig
VantemTest Report 4x19x12 w sigVantemTest Report 4x19x12 w sig
VantemTest Report 4x19x12 w sigDavid M. Densford
 
IRJET- Analysis of Dimpled Sheet and its Optimization using Taguchi Method
IRJET- Analysis of Dimpled Sheet and its Optimization using Taguchi MethodIRJET- Analysis of Dimpled Sheet and its Optimization using Taguchi Method
IRJET- Analysis of Dimpled Sheet and its Optimization using Taguchi MethodIRJET Journal
 
Отчет по ударопрочности боросиликатных линз REETH
Отчет по ударопрочности боросиликатных линз REETHОтчет по ударопрочности боросиликатных линз REETH
Отчет по ударопрочности боросиликатных линз REETHSEA Company
 
TJ14091-Nova-Industries-ASTM-E-84
TJ14091-Nova-Industries-ASTM-E-84TJ14091-Nova-Industries-ASTM-E-84
TJ14091-Nova-Industries-ASTM-E-84Duct Doctors, LLC
 
Commscope Issues and Action Plan Rev 01.ppt
Commscope Issues and Action Plan Rev 01.pptCommscope Issues and Action Plan Rev 01.ppt
Commscope Issues and Action Plan Rev 01.pptpriyapgandhi1
 
NEN-3140 SAMPLE REPORT
NEN-3140 SAMPLE REPORTNEN-3140 SAMPLE REPORT
NEN-3140 SAMPLE REPORTArkady Mitnik
 
Stainless Turbines LLC_Brochure rev.2.3
Stainless Turbines LLC_Brochure rev.2.3Stainless Turbines LLC_Brochure rev.2.3
Stainless Turbines LLC_Brochure rev.2.3Theron Smith
 
Magnetic Cable CE-EMC Test Report - Shenzhen YouCable Technology Co., Ltd
Magnetic Cable CE-EMC Test Report - Shenzhen YouCable Technology Co., LtdMagnetic Cable CE-EMC Test Report - Shenzhen YouCable Technology Co., Ltd
Magnetic Cable CE-EMC Test Report - Shenzhen YouCable Technology Co., LtdErin Yan
 
TRL085B BS_EN12767, v1
TRL085B BS_EN12767, v1TRL085B BS_EN12767, v1
TRL085B BS_EN12767, v1Peter Hoban
 
007 certificate - astm d3161 tas107 - viro reed without netting
007 certificate - astm d3161 tas107 - viro reed without netting007 certificate - astm d3161 tas107 - viro reed without netting
007 certificate - astm d3161 tas107 - viro reed without nettingMaury Janwarin
 
Lateral load Engineering Report
Lateral load Engineering ReportLateral load Engineering Report
Lateral load Engineering ReportRodneyRollins2
 
IRJET- Design and Analysis of Composite Top Frame of Hydraulic Valve Test...
IRJET-  	  Design and Analysis of Composite Top Frame of Hydraulic Valve Test...IRJET-  	  Design and Analysis of Composite Top Frame of Hydraulic Valve Test...
IRJET- Design and Analysis of Composite Top Frame of Hydraulic Valve Test...IRJET Journal
 

Similar to iMovR Lander Lite - ANSI/BIFMA X5.5-2014 Certification (20)

ANSI/BIFMA Certification for iMovR Lander Desk - 41"
ANSI/BIFMA Certification for iMovR Lander Desk - 41"ANSI/BIFMA Certification for iMovR Lander Desk - 41"
ANSI/BIFMA Certification for iMovR Lander Desk - 41"
 
Mold-Testing
Mold-TestingMold-Testing
Mold-Testing
 
Engineering Science WorksheetsTENSILE TESTER KIT ES6TE.docx
Engineering Science WorksheetsTENSILE TESTER KIT ES6TE.docxEngineering Science WorksheetsTENSILE TESTER KIT ES6TE.docx
Engineering Science WorksheetsTENSILE TESTER KIT ES6TE.docx
 
IRJET- Design and Analysis of Pressure Vessel using Software
IRJET- Design and Analysis of Pressure Vessel using SoftwareIRJET- Design and Analysis of Pressure Vessel using Software
IRJET- Design and Analysis of Pressure Vessel using Software
 
LVD report.pdf
LVD report.pdfLVD report.pdf
LVD report.pdf
 
IRJET- Assessment of Mechanical Properties of Bamboo and its Compatibilty...
IRJET-  	  Assessment of Mechanical Properties of Bamboo and its Compatibilty...IRJET-  	  Assessment of Mechanical Properties of Bamboo and its Compatibilty...
IRJET- Assessment of Mechanical Properties of Bamboo and its Compatibilty...
 
VantemTest Report 4x19x12 w sig
VantemTest Report 4x19x12 w sigVantemTest Report 4x19x12 w sig
VantemTest Report 4x19x12 w sig
 
EMC report.pdf
EMC report.pdfEMC report.pdf
EMC report.pdf
 
IRJET- Analysis of Dimpled Sheet and its Optimization using Taguchi Method
IRJET- Analysis of Dimpled Sheet and its Optimization using Taguchi MethodIRJET- Analysis of Dimpled Sheet and its Optimization using Taguchi Method
IRJET- Analysis of Dimpled Sheet and its Optimization using Taguchi Method
 
Отчет по ударопрочности боросиликатных линз REETH
Отчет по ударопрочности боросиликатных линз REETHОтчет по ударопрочности боросиликатных линз REETH
Отчет по ударопрочности боросиликатных линз REETH
 
TJ14091-Nova-Industries-ASTM-E-84
TJ14091-Nova-Industries-ASTM-E-84TJ14091-Nova-Industries-ASTM-E-84
TJ14091-Nova-Industries-ASTM-E-84
 
Commscope Issues and Action Plan Rev 01.ppt
Commscope Issues and Action Plan Rev 01.pptCommscope Issues and Action Plan Rev 01.ppt
Commscope Issues and Action Plan Rev 01.ppt
 
SAR Evaluation Report
SAR Evaluation ReportSAR Evaluation Report
SAR Evaluation Report
 
NEN-3140 SAMPLE REPORT
NEN-3140 SAMPLE REPORTNEN-3140 SAMPLE REPORT
NEN-3140 SAMPLE REPORT
 
Stainless Turbines LLC_Brochure rev.2.3
Stainless Turbines LLC_Brochure rev.2.3Stainless Turbines LLC_Brochure rev.2.3
Stainless Turbines LLC_Brochure rev.2.3
 
Magnetic Cable CE-EMC Test Report - Shenzhen YouCable Technology Co., Ltd
Magnetic Cable CE-EMC Test Report - Shenzhen YouCable Technology Co., LtdMagnetic Cable CE-EMC Test Report - Shenzhen YouCable Technology Co., Ltd
Magnetic Cable CE-EMC Test Report - Shenzhen YouCable Technology Co., Ltd
 
TRL085B BS_EN12767, v1
TRL085B BS_EN12767, v1TRL085B BS_EN12767, v1
TRL085B BS_EN12767, v1
 
007 certificate - astm d3161 tas107 - viro reed without netting
007 certificate - astm d3161 tas107 - viro reed without netting007 certificate - astm d3161 tas107 - viro reed without netting
007 certificate - astm d3161 tas107 - viro reed without netting
 
Lateral load Engineering Report
Lateral load Engineering ReportLateral load Engineering Report
Lateral load Engineering Report
 
IRJET- Design and Analysis of Composite Top Frame of Hydraulic Valve Test...
IRJET-  	  Design and Analysis of Composite Top Frame of Hydraulic Valve Test...IRJET-  	  Design and Analysis of Composite Top Frame of Hydraulic Valve Test...
IRJET- Design and Analysis of Composite Top Frame of Hydraulic Valve Test...
 

More from iMovR

Lander Desk DIY Assembly Manual
Lander Desk DIY Assembly ManualLander Desk DIY Assembly Manual
Lander Desk DIY Assembly ManualiMovR
 
Lander L- & U-Desk Assembly Instructions and User Manual
Lander L- & U-Desk Assembly Instructions and User ManualLander L- & U-Desk Assembly Instructions and User Manual
Lander L- & U-Desk Assembly Instructions and User ManualiMovR
 
The Ensign's Standing Desk Installation and User Manual
The Ensign's Standing Desk Installation and User ManualThe Ensign's Standing Desk Installation and User Manual
The Ensign's Standing Desk Installation and User ManualiMovR
 
Lander Standing Desk User Manual
Lander Standing Desk User ManualLander Standing Desk User Manual
Lander Standing Desk User ManualiMovR
 
Lander Lite DIY Assembly Instructions Rev
Lander Lite DIY Assembly Instructions RevLander Lite DIY Assembly Instructions Rev
Lander Lite DIY Assembly Instructions ReviMovR
 
iMovR Premium Drawer Drill Template
iMovR Premium Drawer Drill TemplateiMovR Premium Drawer Drill Template
iMovR Premium Drawer Drill TemplateiMovR
 
Lander DIY Assembly Guide
Lander DIY Assembly GuideLander DIY Assembly Guide
Lander DIY Assembly GuideiMovR
 
Tech Dock Instruction Manual
Tech Dock Instruction ManualTech Dock Instruction Manual
Tech Dock Instruction ManualiMovR
 
Lander Lite Standing Desk User Manual
Lander Lite Standing Desk User ManualLander Lite Standing Desk User Manual
Lander Lite Standing Desk User ManualiMovR
 
Standing mat-study-texas-am-university-2013
Standing mat-study-texas-am-university-2013Standing mat-study-texas-am-university-2013
Standing mat-study-texas-am-university-2013iMovR
 
INSTALLATION INSTRUCTIONS RONDO MICRO PASS-THROUGH GROMMET WITH COVER (NO POWER)
INSTALLATION INSTRUCTIONS RONDO MICRO PASS-THROUGH GROMMET WITH COVER (NO POWER)INSTALLATION INSTRUCTIONS RONDO MICRO PASS-THROUGH GROMMET WITH COVER (NO POWER)
INSTALLATION INSTRUCTIONS RONDO MICRO PASS-THROUGH GROMMET WITH COVER (NO POWER)iMovR
 
Spacer kit instructions
Spacer kit instructions Spacer kit instructions
Spacer kit instructions iMovR
 
Installation Instructions for Rondo Micro USB-C 18W and 60W
Installation Instructions for Rondo Micro USB-C 18W and 60WInstallation Instructions for Rondo Micro USB-C 18W and 60W
Installation Instructions for Rondo Micro USB-C 18W and 60WiMovR
 
Captains Desk Instruction Manual
 Captains Desk Instruction Manual  Captains Desk Instruction Manual
Captains Desk Instruction Manual iMovR
 
Rondo Micro USB-C 18W Instruction Manual
Rondo Micro USB-C 18W Instruction ManualRondo Micro USB-C 18W Instruction Manual
Rondo Micro USB-C 18W Instruction ManualiMovR
 
Rondo Micro AC Outlet Instruction Manual
Rondo Micro AC Outlet Instruction ManualRondo Micro AC Outlet Instruction Manual
Rondo Micro AC Outlet Instruction ManualiMovR
 
Captain's Desk Standing Desk Instruction Manual
Captain's Desk Standing Desk Instruction ManualCaptain's Desk Standing Desk Instruction Manual
Captain's Desk Standing Desk Instruction ManualiMovR
 
Stowaway Ergonomic Keyboard Tray Installation Manual
Stowaway Ergonomic Keyboard Tray Installation ManualStowaway Ergonomic Keyboard Tray Installation Manual
Stowaway Ergonomic Keyboard Tray Installation ManualiMovR
 
Neemo Ergonomic Chair User Guide
Neemo Ergonomic Chair User GuideNeemo Ergonomic Chair User Guide
Neemo Ergonomic Chair User GuideiMovR
 
iMovR Lander L-Desk Instruction Manual (w or w/o built-in SteadyType Keyboard...
iMovR Lander L-Desk Instruction Manual (w or w/o built-in SteadyType Keyboard...iMovR Lander L-Desk Instruction Manual (w or w/o built-in SteadyType Keyboard...
iMovR Lander L-Desk Instruction Manual (w or w/o built-in SteadyType Keyboard...iMovR
 

More from iMovR (20)

Lander Desk DIY Assembly Manual
Lander Desk DIY Assembly ManualLander Desk DIY Assembly Manual
Lander Desk DIY Assembly Manual
 
Lander L- & U-Desk Assembly Instructions and User Manual
Lander L- & U-Desk Assembly Instructions and User ManualLander L- & U-Desk Assembly Instructions and User Manual
Lander L- & U-Desk Assembly Instructions and User Manual
 
The Ensign's Standing Desk Installation and User Manual
The Ensign's Standing Desk Installation and User ManualThe Ensign's Standing Desk Installation and User Manual
The Ensign's Standing Desk Installation and User Manual
 
Lander Standing Desk User Manual
Lander Standing Desk User ManualLander Standing Desk User Manual
Lander Standing Desk User Manual
 
Lander Lite DIY Assembly Instructions Rev
Lander Lite DIY Assembly Instructions RevLander Lite DIY Assembly Instructions Rev
Lander Lite DIY Assembly Instructions Rev
 
iMovR Premium Drawer Drill Template
iMovR Premium Drawer Drill TemplateiMovR Premium Drawer Drill Template
iMovR Premium Drawer Drill Template
 
Lander DIY Assembly Guide
Lander DIY Assembly GuideLander DIY Assembly Guide
Lander DIY Assembly Guide
 
Tech Dock Instruction Manual
Tech Dock Instruction ManualTech Dock Instruction Manual
Tech Dock Instruction Manual
 
Lander Lite Standing Desk User Manual
Lander Lite Standing Desk User ManualLander Lite Standing Desk User Manual
Lander Lite Standing Desk User Manual
 
Standing mat-study-texas-am-university-2013
Standing mat-study-texas-am-university-2013Standing mat-study-texas-am-university-2013
Standing mat-study-texas-am-university-2013
 
INSTALLATION INSTRUCTIONS RONDO MICRO PASS-THROUGH GROMMET WITH COVER (NO POWER)
INSTALLATION INSTRUCTIONS RONDO MICRO PASS-THROUGH GROMMET WITH COVER (NO POWER)INSTALLATION INSTRUCTIONS RONDO MICRO PASS-THROUGH GROMMET WITH COVER (NO POWER)
INSTALLATION INSTRUCTIONS RONDO MICRO PASS-THROUGH GROMMET WITH COVER (NO POWER)
 
Spacer kit instructions
Spacer kit instructions Spacer kit instructions
Spacer kit instructions
 
Installation Instructions for Rondo Micro USB-C 18W and 60W
Installation Instructions for Rondo Micro USB-C 18W and 60WInstallation Instructions for Rondo Micro USB-C 18W and 60W
Installation Instructions for Rondo Micro USB-C 18W and 60W
 
Captains Desk Instruction Manual
 Captains Desk Instruction Manual  Captains Desk Instruction Manual
Captains Desk Instruction Manual
 
Rondo Micro USB-C 18W Instruction Manual
Rondo Micro USB-C 18W Instruction ManualRondo Micro USB-C 18W Instruction Manual
Rondo Micro USB-C 18W Instruction Manual
 
Rondo Micro AC Outlet Instruction Manual
Rondo Micro AC Outlet Instruction ManualRondo Micro AC Outlet Instruction Manual
Rondo Micro AC Outlet Instruction Manual
 
Captain's Desk Standing Desk Instruction Manual
Captain's Desk Standing Desk Instruction ManualCaptain's Desk Standing Desk Instruction Manual
Captain's Desk Standing Desk Instruction Manual
 
Stowaway Ergonomic Keyboard Tray Installation Manual
Stowaway Ergonomic Keyboard Tray Installation ManualStowaway Ergonomic Keyboard Tray Installation Manual
Stowaway Ergonomic Keyboard Tray Installation Manual
 
Neemo Ergonomic Chair User Guide
Neemo Ergonomic Chair User GuideNeemo Ergonomic Chair User Guide
Neemo Ergonomic Chair User Guide
 
iMovR Lander L-Desk Instruction Manual (w or w/o built-in SteadyType Keyboard...
iMovR Lander L-Desk Instruction Manual (w or w/o built-in SteadyType Keyboard...iMovR Lander L-Desk Instruction Manual (w or w/o built-in SteadyType Keyboard...
iMovR Lander L-Desk Instruction Manual (w or w/o built-in SteadyType Keyboard...
 

Recently uploaded

08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking MenDelhi Call girls
 
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...Igalia
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking MenDelhi Call girls
 
Advantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your BusinessAdvantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your BusinessPixlogix Infotech
 
Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsJoaquim Jorge
 
Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfsudhanshuwaghmare1
 
The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024Rafal Los
 
A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024Results
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘RTylerCroy
 
What Are The Drone Anti-jamming Systems Technology?
What Are The Drone Anti-jamming Systems Technology?What Are The Drone Anti-jamming Systems Technology?
What Are The Drone Anti-jamming Systems Technology?Antenna Manufacturer Coco
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerThousandEyes
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationRadu Cotescu
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...Martijn de Jong
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptxHampshireHUG
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationSafe Software
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Miguel Araújo
 
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdfThe Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdfEnterprise Knowledge
 
GenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationGenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationMichael W. Hawkins
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slidevu2urc
 
08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking MenDelhi Call girls
 

Recently uploaded (20)

08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men
 
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
 
Advantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your BusinessAdvantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your Business
 
Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and Myths
 
Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdf
 
The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024
 
A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘
 
What Are The Drone Anti-jamming Systems Technology?
What Are The Drone Anti-jamming Systems Technology?What Are The Drone Anti-jamming Systems Technology?
What Are The Drone Anti-jamming Systems Technology?
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected Worker
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organization
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
 
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdfThe Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
 
GenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationGenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day Presentation
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slide
 
08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men
 

iMovR Lander Lite - ANSI/BIFMA X5.5-2014 Certification

  • 1. THERMOGENESIS GROUP, INC. TEST REPORT SCOPE OF WORK ANSI/BIFMA X5.5-2014 DESK/TABLE PRODUCTS testing on Lander Lite Standing Desk with Lander Lite 30” x 41” Desktop & Lander Lite 30” x 71” Desktop REPORT NUMBER 104048831GRR-001 ISSUE DATE 11-Sep-2019 PAGES 22 DOCUMENT CONTROL NUMBER RT-AMER-L-GRR-DUR-001 © 2019 INTERTEK
  • 2. REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 4700 Broadmoor Ave SE, Suite 200 Kentwood, MI 49512 Telephone: +1 616 656 7401 Facsimile: +1 616 656 2022 www.intertek.com This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 2 of 22 SECTION 1 CLIENT INFORMATION Attention: Ron Wiener Thermogenesis Group, Inc. 14260 NE 21st Street Bellevue, WA 98007 USA Phone: (206) 905-9435 Email: ron@imovr.com James Jantz Dorian Bako Test Engineer Project Reviewer
  • 3. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 3 of 22 SECTION 2 SUMMARY AND CONCLUSION Date Received: 29-Aug-2019 Dates Tested: 03-Sep-2019 to 11-Sep-2019 DESCRIPTION OF SAMPLES AS RECEIVED Part Description: Lander Lite Standing Desk with Lander Lite 30” x 41” Desktop & Lander Lite 30” x 71” Desktop Condition of Samples: Production Number of Samples Received: Two (2) SAMPLE ID PART NO. DESCRIPTION 1 Z-LN3B-REA3041NC Lander Lite 30” x 41” Desk Top 2 LN-REA3071BW Lander Lite 30” x 71” Desk Top The Lander Lite Standing Desk was used as the base for both Desk Tops listed above. WORK REQUESTED/APPLICABLE DOCUMENTS ANSI/BIFMA X5.5-2014 DESK/TABLE PRODUCTS Intertek quote Qu-00996322 CONCLUSION SAMPLE ID ANSI/BIFMA X5.5-2014 DESK/TABLE PRODUCTS RESULTS 1 4.3 Stability Under Vertical Load Test CONFORMING 2 4.3 Stability Under Vertical Load Test CONFORMING 2 5.2 Concentrated Functional Load Test CONFORMING 2 5.3 Distributed Functional Load Test CONFORMING 2 5.4 Concentrated Proof Load Test CONFORMING 2 5.5 Distributed Proof Load Test CONFORMING 2 6. Top Load Ease Cycle Test CONFORMING 2 7. Desk/Table Unit Drop Test CONFORMING 2 8. Leg Strength Test CONFORMING 2 15. Work Surface Vertical Adjustment Test CONFORMING SAMPLE DISPOSITION The samples were returned to client upon test completion.
  • 4. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 4 of 22 TEST EQUIPMENT: ASSET ID DESCRIPTION CAL DATE CAL DUE 138012 Scale/0-1,000# 10/15/2018 10/15/2019 138039.10 WEIGHT BAG VBU VBU 138238 CONTROLLER CBU CBU 138394 0 to 1000lb Load Cell 8/21/2019 8/21/2020 138397 Portable Vertical Loading Test Stand VBU VBU 138500.10 Stopwatch 10/02/2018 10/02/2019 138519 48" STRAIGHT-EDGE 12/17/2018 12/17/2019
  • 5. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 5 of 22 SECTION 3 4.3 STABILITY UNDER VERTICAL LOAD TEST: Date Received: 29-Aug-2019 Date Tested: 03-Sep-2019 to 11-Sep-2019 Location Tested: Intertek Kentwood, MI DESCRIPTION OF SAMPLES: Part Description: Lander Lite Standing Desk with Lander Lite 30” x 41” Desktop & Lander Lite 30” x 71” Desktop Number of Samples Tested: Two (2) TEST PROCEDURE: Test Method: Per ANSI/BIFMA X5.5-2014 Test No. 4.3: The unit shall be levelled. Placement of the load shall be on a 12” diameter disk 1” from the edge at the least stable position. Top Load: 125 lbs. ACCEPTANCE CRITERIA: Per ANSI/BIFMA X5.5-2014 Test No. 4.3: The unit shall not tip over. RESULTS: SAMPLE ID STATIC LOAD RESULTS 1 125 lbs. Conforming 2 125 lbs. Conforming The submitted samples met the acceptance criteria of the test described above. Refer to the following pages for photographs.
  • 6. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 6 of 22 Stability Under Vertical Load Test –30” x 41” Desktop – Sample 1
  • 7. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 7 of 22 Stability Under Vertical Load Test – Sample 2
  • 8. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 8 of 22 5.2 – 5.5 UNIT STRENGTH TESTS: Date Received: 29-Aug-2019 Date Tested: 03-Sep-2019 Location Tested: Intertek Kentwood, MI DESCRIPTION OF SAMPLES: Part Description: Lander Lite Standing Desk with Lander Lite 30” x 71” Desktop Number of Samples Tested: One (1) TEST PROCEDURE: Test Method: Per ANSI/BIFMA X5.5-2014 Test Nos. 5.2 – 5.5: ACCEPTANCE CRITERIA: Per ANSI/BIFMA X5.5-2014 Test Nos. 5.2 – 5.5: Functional Load: There shall be no loss of serviceability. Proof Load: There shall be no major change in the structural integrity. RESULTS: SAMPLE ID SURFACE TO BE TESTED (CLASS) WORK SURFACE RESULTS 2 Surface Size 202” Concentrated Loads Functional: 200 lbs. Conforming Proof: 300 lbs. Conforming Distributed Loads Functional: 303 lbs. Conforming Proof: 465 lbs. Conforming The submitted sample met the acceptance level criteria of the test described above. Refer to the following pages for photographs.
  • 9. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 9 of 22 Concentrated Functional Load Test – Sample 2
  • 10. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 10 of 22 Concentrated Proof Load Test – Sample 2
  • 11. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 11 of 22 Distributed Functional Load Test – Sample 2
  • 12. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 12 of 22 Distributed Proof Load Test – Sample 2
  • 13. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 13 of 22 6. TOP LOAD EASE CYCLE TEST: Date Received: 29-Aug-2019 Date Tested: 10-Sep-2019 to 11-Sep-2019 Location Tested: Intertek Kentwood, MI DESCRIPTION OF SAMPLES: Part Description: Lander Lite Standing Desk with Lander Lite 30” x 71” Desktop Number of Samples Tested: One (1) TEST PROCEDURE: Test Method: Per ANSI/BIFMA X5.5-2014 Test No. 6: Number of Cycles: 10,000 Load: 200 lbs. Cycles Per Minute: 14 ± 6 Load Drawers with: 0.017 lbs./cu. in. Load Area: 16” Diameter ACCEPTANCE CRITERIA: Per ANSI/BIFMA X5.5-2014 Test No. 6: There shall be no loss of serviceability to the unit. A pull force to overcome anti-rebound or interlock and to fully extend the drawer shall not exceed 11.2 lbs. RESULTS: SAMPLE ID NUMBER OF CYCLES RESULTS 2 10,000 Conforming The submitted sample met the acceptance level criteria of the test described above. Refer to the following page for photograph.
  • 14. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 14 of 22 Top Load Ease Cycle Test – Sample 2
  • 15. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 15 of 22 7. DESK/TABLE UNIT DROP TEST: Date Received: 29-Aug-2019 Date Tested: 11-Sep-2019 Location Tested: Intertek Kentwood, MI DESCRIPTION OF SAMPLES: Part Description: Lander Lite Standing Desk with Lander Lite 30” x 71” Desktop Number of Samples Tested: One (1) TEST PROCEDURE: Test Method: Per ANSI/BIFMA X5.5-2014 Test No. 7: NOTE: Test applies to freestanding Category 1 Desk or Tables that are less than 72” in length. Test does not apply to units with casters or keyboard tables. Set all adjustable features at midpoint. UNIT WEIGHT DROP HEIGHT <45 kg (100 lbs.) 180 mm (7.1 in.) 45 – 90 kg (100-200 lbs.) 120 mm (4.7 in.) >90 – 136kg (200-300 lbs.) 60 mm (2.4 in.) >136 kg (300 lbs.) N/A Unit Weight: 102 lbs. ACCEPTANCE CRITERIA: Per ANSI/BIFMA X5.5-2014 Test No. 7: There shall be no loss of serviceability. RESULTS: SAMPLE ID DROP HEIGHT RESULTS 2 4.7” Conforming The submitted sample met the acceptance criteria of the test described above. Refer to the following page for photograph.
  • 16. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 16 of 22 Desk/Table Unit Drop Test – Sample 2
  • 17. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 17 of 22 8. LEG STRENGTH TEST: Date Received: 29-Aug-2019 Date Tested: 11-Sep-2019 Location Tested: Intertek Kentwood, MI DESCRIPTION OF SAMPLES: Part Description: Lander Lite Standing Desk with Lander Lite 30” x 71” Desktop Number of Samples Tested: One (1) TEST PROCEDURE: Test Method: Per ANSI/BIFMA X5.5-2014 Test No. 8: Unit Weight: 102 lbs. NOTE: Based on the desk or table category, calculate functional and proof loads. ACCEPTANCE CRITERIA: Per ANSI/BIFMA X5.5-2014 test no. 8: Functional Force: There shall be no loss of serviceability. Proof Force: There shall be no sudden and major change in the structural integrity of the product. Loss of serviceability is acceptable. RESULTS: SAMPLE ID SURFACE TO BE TESTED (CLASS) RESULTS 2 Functional Force Inward on Leg: 100 lbf. Conforming Outward on Leg: 50 lbf. Conforming Proof Force: Inward on Leg: 150 lbf. Conforming Outward on Leg: 75 lbf. Conforming The submitted sample met the acceptance level criteria of the test described above. Refer to the following pages for photographs.
  • 18. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 18 of 22 Leg Strength Test – Functional – Sample 2
  • 19. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 19 of 22 Leg Strength Test – Proof – Sample 2
  • 20. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 20 of 22 15. WORK SURFACE VERTICAL ADJUSTMENT TEST: Date Received: 29-Aug-2019 Date Tested: 03-Sep-2019 to 08-Sep-2019 Location Tested: Intertek Kentwood, MI DESCRIPTION OF SAMPLES: Part Description: Lander Lite Standing Desk with Lander Lite 30” x 71” Desktop Number of Samples Tested: One (1) TEST PROCEDURE: Test Method: Per ANSI/BIFMA X5.5-2014 Test No. 15: Number of Cycles: 1,000 in each quartile. Load: 100 lbs. Cycle Rate: Recommended by manufacturer or six (6) cycles per minute. ACCEPTANCE CRITERIA: Per ANSI/BIFMA 5.5-2014 Test No. 15: There shall be no loss of serviceability. For tables with crank driven adjustment mechanisms, the operating force on the handle to adjust the table shall not exceed 11.2 lbf. RESULTS: SAMPLE ID QUARTILE RESULTS 2 1 Conforming 2 Conforming 3 Conforming 4 Conforming The submitted sample met the acceptance level criteria of the test described above. Refer to the following page for photograph.
  • 21. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 21 of 22 Work Surface Vertical Adjustment Test – Sample 2
  • 22. TEST REPORT FOR THERMOGENESIS GROUP, INC. Report No.: 104048831GRR-001 Date: 11-Sep-2019 P.O.: 55338 Rev. Date: 5/16/17, Doc. # RT-AMER-L-GRR-DUR-001 Page 22 of 22 SECTION 4 REVISIONS MADE TO TEST REPORT DATE REVISION DESCRIPTION REVISED BY REVISED BY 11-Sep-2019 Initial release. James Jantz