FG-2035 is Focus security system wired glass break detector.
It is an advanced microprocessor based acoustic glass break detector. It is for flush or surface wall, ceiling mounting. It adopts intrusion technology advanced glass-breaking pattern analysis of both low frequency "flex" and high frequency "shatter" channels. It detects the breaking of most common types framde glass panels while ignoring false alarms.
Specifications:
FG-2035 is for flush (single gang box) or wall / ceiling mounting for up to 30 inch (9m) ranges.
It is suitable for most common types of plates, tempered, laminated glass.
Minimum size for all types of glass: 30cm*30cm (12 inch *12 inch)
Thickness of plate tempered: 3.2mm-6.4mm (1/8 inch - 1/4 inch)
Laminated, wired: 64mm (1/4 inch)
No adjustments necessary, each unit is bully calibrated by factory.
Will not alarm if glass panel broken from inside or glass dropped on floor.
Active and passive microphone supervision, verifles unit is in working condition.
Full remote test using glass break simulator, no need to open unit.
Optional ceiling , wall mount bracket available for opeional mounting and performance.
Electrical current consumption: 20mA at 12V (24mA max)
Shop it at https://vedardalarm.com/fg2035-glass-break-detector-p-147
Digital Watchdog DWC-V4567WTIR User ManualJMAC Supply
Buy the Digital Watchdog DWC-V4567WTIR at JMAC Supply.
https://www.jmac.com/Digital_Watchdog_DWC_V4567WTIR_p/digital-watchdog-dwc-v4567wtir.htm?=slideshare
Digital Watchdog DWC-V4567WTIR User ManualJMAC Supply
Buy the Digital Watchdog DWC-V4567WTIR at JMAC Supply.
https://www.jmac.com/Digital_Watchdog_DWC_V4567WTIR_p/digital-watchdog-dwc-v4567wtir.htm?=slideshare
The Saker Plus is a large venue electric/motorized projector screen. The Saker Plus utilizes our GREENGUARD Gold Certified MaxWhite™ (matte white) front projection material, which has a 1.1 Gain and a wide viewing angle. For more details visit at http://www.elitescreens.com/products/electric-wall-ceiling-projection-screens
This is our brand new product, 992BK - Video Door Phone. The system is an intelligent product for home, office and business security based on advanced CCTV
system. It maximizes safety by seeing the visitor before opening the door.
Even in the dark, night vision with infrared leds makes you identify the visitor.
The RockTale is a unique mechanical and electronic device that provides early warning of roof instability in underground mines. The device consists of two LED lights (blue and red) and provides warning of roof or hanging wall separation,
Digital Watchdog DWC-V4363TIRB User ManualJMAC Supply
Buy the Digital Watchdog DWC-V4363TIRB at JMAC Supply.
https://www.jmac.com/Digital_Watchdog_DWC_V4363TIRB_p/digital-watchdog-dwc-v4363tirb.htm?=slideshare
Professional wireless fire alarm and fire linkage security system.
It is easy to install without wiring.
It is easy to program with free PC software.
It is professional security fire alarm and automatical fire fighting with loop linkage and direct linkage with smoke exhaust, electric fan, hydrant etc.
Complete wireless fire alarm system at vedardsecurity.com
Gas fire extinguishing device and foam fire extinguishing device usually adopt independent fire extinguishing controller. When the fire detector in its protected area is directly connected to the fire extinguishing controller, the alarm linkage control of each stage and the feedback signal of the system shall be immediately fed back to the fire extinguishing linkage controller, and the fire extinguishing linkage controller shall start the alarm linkage control process according to the specification requirements.
After the fire linkage controller receives the feedback signal, is it necessary to activate all the fire audible and visual alarms and fire broadcasting in the building? Is it necessary to turn on the smoke control and exhaust system and the emergency lighting evacuation indicator system?
More Related Content
Similar to Glass break intrusion alert home security system manual
The Saker Plus is a large venue electric/motorized projector screen. The Saker Plus utilizes our GREENGUARD Gold Certified MaxWhite™ (matte white) front projection material, which has a 1.1 Gain and a wide viewing angle. For more details visit at http://www.elitescreens.com/products/electric-wall-ceiling-projection-screens
This is our brand new product, 992BK - Video Door Phone. The system is an intelligent product for home, office and business security based on advanced CCTV
system. It maximizes safety by seeing the visitor before opening the door.
Even in the dark, night vision with infrared leds makes you identify the visitor.
The RockTale is a unique mechanical and electronic device that provides early warning of roof instability in underground mines. The device consists of two LED lights (blue and red) and provides warning of roof or hanging wall separation,
Digital Watchdog DWC-V4363TIRB User ManualJMAC Supply
Buy the Digital Watchdog DWC-V4363TIRB at JMAC Supply.
https://www.jmac.com/Digital_Watchdog_DWC_V4363TIRB_p/digital-watchdog-dwc-v4363tirb.htm?=slideshare
Similar to Glass break intrusion alert home security system manual (20)
Professional wireless fire alarm and fire linkage security system.
It is easy to install without wiring.
It is easy to program with free PC software.
It is professional security fire alarm and automatical fire fighting with loop linkage and direct linkage with smoke exhaust, electric fan, hydrant etc.
Complete wireless fire alarm system at vedardsecurity.com
Gas fire extinguishing device and foam fire extinguishing device usually adopt independent fire extinguishing controller. When the fire detector in its protected area is directly connected to the fire extinguishing controller, the alarm linkage control of each stage and the feedback signal of the system shall be immediately fed back to the fire extinguishing linkage controller, and the fire extinguishing linkage controller shall start the alarm linkage control process according to the specification requirements.
After the fire linkage controller receives the feedback signal, is it necessary to activate all the fire audible and visual alarms and fire broadcasting in the building? Is it necessary to turn on the smoke control and exhaust system and the emergency lighting evacuation indicator system?
Gas fire extinguishing control system is mainly composed of gas fire extinguishing controller, fire detectors, manual /automatic switch, emergency start/stop button, sound/light alarm, gas spraying indicator light, etc.
Among them, Generally, smoke detectors and heat detectors are used as fire detectors.
Manual alarm button or other types of fire detectors can also be used in special cases.
Gas extinguishing controller linkage control gas fire extinguishing equipment, linkage control fan, Air valve fire valve, Ventilation and air conditioning, Automatic doors and Windows and other equipment. And receive feedback signals.
The gas fire extinguishing system project requires the implementation of simulated start-up tests to verify the reliability of the gas fire extinguishing system. The simulated start test shall be carried out after the installation and debugging of gas equipment, alarm equipment and gas fire extinguishing equipment.
1. Manually start the experiment
2, automatic start test.
Temperature measuring electrical fire monitoring detector can detect the change of temperature parameters in the protected line, and can monitor the abnormal temperature of the line or connection point.
The detector shall be installed in the key heating parts of the cable connector terminal.
Temperature measuring electrical fire monitoring and detection includes signal processing unit and temperature measuring sensor.
The independent electric fire monitoring detector has the function of monitoring and alarm, the detector sends out sound and light alarm signal when alarm, and displays the alarm value, which can be used independently.
When there is no fire control room and the number of electrical fire monitoring detectors is not more than 8, independent electrical fire monitoring detectors can be used.
Each signal processing unit of the independent electrical fire monitoring detector can equip up to 4 sensors.
When the automatic fire alarm system is provided, the alarm information and fault information of the independent electrical fire monitoring detector shall be displayed on the graphic display device of the fire control room or the centralized fire alarm controller.
The alarm linkage control of smoke control system refers to the alarm linkage control of mechanical smoke control system.
According to the different parts of the setting, the mechanical pressurized air supply system can be divided into the mechanical pressurized air supply system in the stairwell and front room, the mechanical pressurized air supply system in the refuge layer and the mechanical pressurized air supply system in the refuge aisle.
Mechanical pressurized air supply system in the stairwell and front room:
Linkage control should be divided according to fire protection zones, including automatic, manual, chain start and other control methods.
Fire alarm controller and fire linkage controller are integrated products, called the linked fire alarm controller.
The main components of the linked fire alarm controller include motherboard, display board, bus linkage control panel, multi-line linkage control panel, network interface component, power supply, loop board and so on.
Most fire alarm systems adopt two bus system.
Two bus is a bus technology that combines power supply line and signal line. Two buses save construction and cable costs, greatly facilitating on-site construction and later maintenance.
There are two forms of tree bus and ring bus in bus system.
The loop of the tree bus is unidirectional, and if a fault occurs at any point in the line, the equipment behind it cannot be used.
The loop of the ring bus is closed loop. With the help of the bus isolator, a fault at one point in the line will not affect the operation of the rest of the system.
The design of the regional fire alarm system shall comply with the following requirements:
1. The system shall consist of fire detector, manual fire alarm button, fire audible and visual alarm and fire alarm controller.
2. The system may include a graphic display device in the fire control room and an fire alarm displayer to indicate the fire floor.
3. The fire control room can not be set up for the regional fire alarm system, but the fire alarm controller should be set up in the place with people on duty.
4. When the system is equipped with the graphic display device in the fire control room, the graphic display device performs the functions of remote information transmission and remote query.
5. If no graphic display device is set in the system, fire alarm transmission device should be set. Similar functions are performed by fire alarm transmission equipment.
According to the specification requirements, the centralized alarm system and the control center alarm system need to be equipped with graphic display device (CRT system).
The graphic display device is installed in the fire control center, which is used to simulate the building plane layout of the fire trigger device and linkage device on site, and can truthfully reflect the fire, linkage condition and fault situation on site.
The graphic display device can display the general layout of the building, the building plan of each protected object, the system diagram, and the names and evacuation routes of each protected object and the main parts.
And can display automatic fire alarm and linkage control system and its control of all kinds of fire fighting equipment name, physical location and dynamic information of each fire fighting equipment.
Automatic fire alarm system is the main part of fire control system.
Automatic fire alarm system includes fire early warning system, fire detection alarm and linkage control system.
The linkage control system includes fire hydrant button, fire alarm, various input and output modules, fire appliance control device, fire broadcasting system, fire telephone system, graphic display device, emergency lighting, evacuation indicating system, etc.
Fire early warning system is an independent subsystem of automatic fire alarm system. It mainly includes combustible gas detection and alarm system and electrical fire monitoring system.
Combustible gas detection and alarm system is mainly used in the use, production of combustible gas or combustible steam places.
Alarm area is a unit that divides the warning range of automatic fire alarm system according to fire zone or floor. An alarm area includes a plurality of detection areas.
The purpose of dividing the alarm area is to determine the location of the alarm and fire. At the same time, it is convenient to solve the problem of fire control system linkage design.
The alarm area should be divided according to the fire zone or floor. You can also divide several adjacent fire zones or floors that need to be simultaneously linked with fire fighting equipment into an alarm area in case of fire.
Bus short circuit isolator is simply called bus isolator.
It is necessary to install bus short circuit isolator in bus automatic fire alarm system. When a bus fails, the bus isolator automatically separates the faulty bus part from the whole system to ensure the normal operation of the rest of the system.
At the same time, the fire alarm controller indicates the part number of the isolated parts, which is convenient for maintenance.
When the fault is rectified, the bus isolator automatically reintegrates the isolated part into the system.
Manual fire alarm button is a manual fire alarm device.
After the alarm button is pressed, the alarm signal is sent to the fire alarm controller through the bus loop.
The controller displays the position, code and annotation information of the alarm button, and sends out sound and light alarm signal.
The alarm button should be set with a red start confirmation light. After pressing the alarm button, the start confirmation light should be lit and kept until the alarm state is reset.
The input module, also known as the monitoring module, is used to receive the action signal of the monitored device and can be connected to the monitored device with normally open or normally closed signal output.
The input module adds an address code to the action signal of the monitored device, and transmits it to the fire alarm controller through the signal bus to issue an alarm signal or linkage trigger signal.
The input module can be equipped with all kinds of equipment that need feedback signals on the site, such as water flow indicator, pressure switch, signal valve control cabinet, and all kinds of external linkage equipment that can provide switch signals.
According to the code, carbon monoxide detectors should be installed in places where carbon monoxide leakage is possible.
For the choice of carbon monoxide detector, you may have the following questions:
Carbon monoxide is both a combustible gas and a toxic gas,should I choose a carbon monoxide detector or a combustible gas detector?
More details can be found at https://www.vedardsecurity.com
The gas fire extinguishing control system mainly consists of gas fire extinguishing controller, fire detector, manual automatic switch, emergency start and stop button, sound and light alarm, gas spraying indicator light and so on.
The fire detector generally adopts smoke fire detector and temperature fire detector. In special cases, manual alarm buttons or other types of fire detectors can also be used.
Gas fire extinguishing controller linkage control gas fire extinguishing equipment, linkage control fan, air valve, fire valve, ventilation and air conditioning, automatic doors and windows and other equipment, and receive feedback signals.
More professional fire alarm system instruction can be found at https://www.vedardsecurity.com
Residual current electrical fire detector is used to monitor the change of residual current value in the protected line.
When the residual current in the protected electrical line exceeds the alarm set value, it can send alarm and control signals.
It is generally composed of residual current sensor and signal processing unit.
Read more instruction of fire alarm systems from Vedard Security Alarm Technology at https://www.vedardsecurity.com
NO1 Uk Amil Baba In Lahore Kala Jadu In Lahore Best Amil In Lahore Amil In La...Amil baba
Contact with Dawood Bhai Just call on +92322-6382012 and we'll help you. We'll solve all your problems within 12 to 24 hours and with 101% guarantee and with astrology systematic. If you want to take any personal or professional advice then also you can call us on +92322-6382012 , ONLINE LOVE PROBLEM & Other all types of Daily Life Problem's.Then CALL or WHATSAPP us on +92322-6382012 and Get all these problems solutions here by Amil Baba DAWOOD BANGALI
#vashikaranspecialist #astrologer #palmistry #amliyaat #taweez #manpasandshadi #horoscope #spiritual #lovelife #lovespell #marriagespell#aamilbabainpakistan #amilbabainkarachi #powerfullblackmagicspell #kalajadumantarspecialist #realamilbaba #AmilbabainPakistan #astrologerincanada #astrologerindubai #lovespellsmaster #kalajaduspecialist #lovespellsthatwork #aamilbabainlahore#blackmagicformarriage #aamilbaba #kalajadu #kalailam #taweez #wazifaexpert #jadumantar #vashikaranspecialist #astrologer #palmistry #amliyaat #taweez #manpasandshadi #horoscope #spiritual #lovelife #lovespell #marriagespell#aamilbabainpakistan #amilbabainkarachi #powerfullblackmagicspell #kalajadumantarspecialist #realamilbaba #AmilbabainPakistan #astrologerincanada #astrologerindubai #lovespellsmaster #kalajaduspecialist #lovespellsthatwork #aamilbabainlahore #blackmagicforlove #blackmagicformarriage #aamilbaba #kalajadu #kalailam #taweez #wazifaexpert #jadumantar #vashikaranspecialist #astrologer #palmistry #amliyaat #taweez #manpasandshadi #horoscope #spiritual #lovelife #lovespell #marriagespell#aamilbabainpakistan #amilbabainkarachi #powerfullblackmagicspell #kalajadumantarspecialist #realamilbaba #AmilbabainPakistan #astrologerincanada #astrologerindubai #lovespellsmaster #kalajaduspecialist #lovespellsthatwork #aamilbabainlahore #Amilbabainuk #amilbabainspain #amilbabaindubai #Amilbabainnorway #amilbabainkrachi #amilbabainlahore #amilbabaingujranwalan #amilbabainislamabad
MATHEMATICS BRIDGE COURSE (TEN DAYS PLANNER) (FOR CLASS XI STUDENTS GOING TO ...PinkySharma900491
Class khatm kaam kaam karne kk kabhi uske kk innings evening karni nnod ennu Tak add djdhejs a Nissan s isme sniff kaam GCC bagg GB g ghan HD smart karmathtaa Niven ken many bhej kaam karne Nissan kaam kaam Karo kaam lal mam cell pal xoxo
Drugs used in parkinsonism and other movement disorders.pptx
Glass break intrusion alert home security system manual
1. MAIN FEATURES
The FG-2035 is an advanced microprocessor based
Acoustic Glass Break Detector,for flush or surface wall/
ceiling mounting,using advanced glass-breaking pattern
analysis of both low frequency "flex"and high frequency
"shatter"channels.lt will detect the breaking of most
common types of framde glass panes while ignoring false
alarms.
FG-2035 for flush (single gang box) or wall/ceiling
mounting for up to 30'(9m) ranges.
Suitable for most common types of plats,tempered,
laminated and wired glass.
Minimum size for all types of glass:30cm 30cm(12" 12")
Thickness Plate
Tempered.
Laminated,Wired 64mm(1/4")
No adjustments necessary-each unit is bully calibrated
at factory.
Will not alarm if glass pane broken from inside or glass
dropped on floor.
Active and passive microphone supervision-verifles unit
is in working condition..
Full remote test using Glass Break Simulator-no
need to open unit.
optional ceiling/wall mount bracket available for
optimal mounting and performance.
FG-2035 range of coverage depends on the type of
glass (see table 1) and the angle between FG-2035
and glass (see Table 2 Fig 1).
Verify that the distance between the FG-2035 and the
furthest point on the protected glass does not exceed the
maximum specified range taking into account the reduced
range due to angle (see Fig 2)
FG-2035 can be mounted in a single gang box using flu
-sh mount adapter or on wall or ceiling.For optimal results
the FG-2035 should be mounted as nearly opposite the glass
area to be protected.as shown in Fig 3.
Fig 3
FG-2035 Mounting Options Opposite
wall-Mount (For optimal results
FG-2035 is centered opposite glass)
Ceiling Mount (for optimal results
FG-2035 is centered and directed
towards protected glass using
Bracket)
Corner Mount (choose corner opposite
glass to be protected).
Side Wall-Mount (not recommended
as is not opposite glass-see range
versus angle diagram.Test carefully
at both ends of glass using Tester)
a)When Ceiling Mounted use The bracket for best
preformance.
b)Do not mount FG-2035 on same wall
as protected glass.
c)Avoid installing the FG-2035 near sources of loud
noises or vibrations (air conditioners,fans,compressors,
streros,etc.)
3.2mm-6.4mm
(1/8"-1/4")
}
STEP RANGE OF COVERAGE
1
Type of
Glass
Mode
FG-2035
Plate
Size Thickness
Max.
Range
Tempered.
Laminated.Wired
Minnimum
50 50cm
(20" 20")
Minnimum
30 30cm
(12" 12")
3.2-6.4mm
(1/8"-1/4")
9m
(30ft)
9m
(30ft)
Minnimum
30 30cm
(12" 12")
6.4m
(1/4")
6m
(20ft)
Size Thickness
Max.
Range
Table 2:FG-2035 range of coverage accordingto angle
Angle(degrees) Percent of max range
0
15
30
45
60
75
90
100
96
87
70
50
26
0
75
60 45
30
15
0
FG-2035
Percentage of
Maximum
Range as
function of
angle between
FG-2035 and
glass.
FG-2035
GENERAL DESCRIPTION
INSTALLATION PROCEDURE
Table 1:FG-2035 range according to glass type
Table 1:FG-2035 range according to glass type
ANGLE
WINDON
FG-2035
Fig 2:
Fig 1:
Angle
between
FG-2035
and glass SIDE VIEW
There should be no obstructions between the FG-2035
and the protected glass.
Curtains and blinds may reduce the effective range.
Sound absorbing materials in the protected area may
reduce the range.
Important: Other factors effecting range:
STEP RANGE OF LOCATION
2
Note:
STEP MOUNTING
3
FLUSH MOUNTING
1) Screw mounting bracket into single gang box
2)Insert cable through knockout in FG-2035 base &
insert wires into terminal block,snap PCB into base.
3)Snap on front cover & secure with screw provided.
Snap complete FG-2035 unit into mounting bracket.
4)Snap on front cover of mounting bracket
NOTE:To remove trimplate.squeeze the top and bottom
simultaniously and pull away.
Open the cover using a flat screwdriver.
Remove the PCB in order to facilitate
ease of wiring(see FIG 4).
Open the required mounting and cable
holes(see Fig5).
Insert the cable through the cable hole
and mount the rear cover in its final location.
Seal the remaining holes with sealant.
Snap back the PCB(if removed).
Fig 4: Fig 5:
STEP TERMINAL WIRING
4
WALL/CEILING MOUNTING
Wire the cable to the Terminal Block as follows (see fig6):
12VDC: Power supply inputs
ALARM: Normally-Closed relay outputs
TAMPER: Normally-Closed Tamper
switch outputs
EOL: End-of-Line resistor connection
Fig 6: FG-2035 PCB-General View
HOLDING TABS
MEMORY JUMPER
FULL TEST BUTTON
TAMPER SWITCH
ALARM RELAY
HOLDING TABS
SCREW HOLE
STEP TESTING
5
Testing should be performed using the FG-2035 tester
which has been specially designed and calibrated to give
accurate range test results.
Set lower selector switch on tester to CODE setting,Press
operating button on tester to put unit into test mode.
FG-2035 LED will blink every 2 seconds for 2 minutes.
HIGH FREQUENCY(AUDIO)TEST:Position the Glass
Break Simulator at the farthest point on the protected
glass and face it into the room.Set lower selector to
GLASS setting and upper to type of glass to be simulated.
Generate glass-break sound by perssing operating
button.Verify that FG-2035 LED turns on for 3 seconds and
ALARM relay is activated.
LOW FREQUENCY TEST:Tap the window gently,(Caution
breaking glass may cause injury).Verity that the FG-2035
producess several rapid flashes of its LED in conjunction
with each tap.TheALARM relay is not activated in this case.
All tests should be conducted under worst-case
conditions.All sounds should be generated behind curtains
or blinds,it present.
Note:
1 2 3 4
ENVIRONMENTAL TEST
Operate all devices in the protected region that may interfere
with the detectorl.including air conditioners.fans.radios etc.
Observe the FG-2035 and note any disturbances.
if disturbances occur,re-position the unit and re-test,Turn all
noise generating equipment off and wait until unit returns to
NORMAL mode.
Note:The FG-2035 will return toNORMAL mode after two
minutes.setting the "CODE" swith and pressing the "Manual"
button at any time will initiate another two minutes of Full
Remote Test Mode.
If tester is not available test mode can be initiated by
inserting screwdriver in slot on front cover (to the right of the
LED) and pressing the test button. The FG-2035LED will blink
every 2 seconds. FG-2035 will automatically return to normal
mode after 5 minutes. Functional test can now be pertormed
using another tester. Pressing the button again during the test
mode will immediately return unit to normal mode.
STEP MEMORY INDICATION
6
To use the MEMORY option-remove the Jumper.The LED is
latched on the first alarm.
The LED is reset by temporarilly removing the power from the
detector (using a Switched 12V line from the control panel).
There are three types of indication in normal mode:
Active Supervision:Any loud sounds such as clapping,
whistling or key-jingling shoukd produce a flash of the
FG-2035's LED. This verifies that the FG-2035 is acttive.
The alarm relay is not opened.
Passive Supervision:The FG-2035 continuously monitors its
audio channet.if no sounds are registered for more than 24
hours the LED will flash rapidy,This indication will persist
until a sound is registered.The alarm relay is not opened.
Alarm:On detection of framed glass being brokenfrom outside
the LED will light continuously for 3seconds and the alarm
relay will open.
STEP NORMAL OPERATION
7
2. LED INDICATIONS
Sound LED Indication Alarm Relay
Low frequency
"Flex"wave
No indication
High Frequency
"Shatter"sound
LED flashes in
conjunction with sound
LED off.(After 24 hours
without any environmental
sounds the LED flashes
rapldly to indicte possible
dead microphone,and turns
off after a sound is
registered)
No sound
LED turns on for 3 seconds.
(inlatched mode LED stays
on until power is diconnected)
Frame Glass
Breaking
Activated
No sound
LED blinks once every 2
seconds to indicate
testmode
Low Frequency
"Flex"wave
LED flashes rapidly
High Frequency
"Shatter"sound
LED turns on for 3
seconds
Activated
Normal
Mode
Test
Mode
SPECIFICATIONS
ENVIRONMENTAL
ELECTRICAL
CURRENT CONSUMPTION
20mA at 12V (24mA max)
VOLTAGE REQUIREMENTS 9.3-16 VDC
ALARM CONTACTS NC.24 VDC, 50mA
TAMPER CONTACTS NC,24 VDC,0.5A
ACOUSTIC SENSOR
Omni Directional Microphone
PHYSICAL
SIZE: 90 90 22mm(3.5 3.5 0.9in.)
WIEIGHT: 63.70g(2.25 oz.)
GLASS
TYPES: Plate,laminated.wired&tempered.
SIZE: 30 30cm(12" 12")minimum
OPERATING TEMPERATURE 0 to55 (32 to131 )
STORAGE TEMPERATURE -20 to66 (14 to-140 )
F F
F F