Fuel level sensors DUT-E for accurate fuel tank monitoring, prevention of fuel theft and fuel use accounting. Sensors can be used within GPS tracking solutions for fleets of any sizes and purposes.
2. 2
Fuel level sensor DUT-E is
designed for precise fuel level
measurement in all kinds of
vehicle tanks, also in tanks of
fixed installations.
It can be used as a part of
fleet management system for
controlling fuel drainings and
fuel fillings, fuel consumption
monitoring.
3. 3
DUT-Е А5 Output voltage range 1.5-4.5 V.
DUT-Е 10 Output voltage range 2.5-9 V.
DUT-Е AF Output voltage/frequency
DUT-Е 232/485
RS232/RS485
DUT-Е 485
DUT-E CAN CAN j1939
4. Parameter Value
Measurement inaccuracy error for stationary fuel
tanks and stationary vehicles, %, not more
≤0,2
Measurement inaccuracy error for moving vehicles,
%, not more
≤1
Supply voltage, V 10 - 50
Overvoltage protection, V Up to 100
Operating temperature, °C -40 .. +85
Length, analog, mm. 180 - 2500
Length, digital, mm. 700 - 1400
4
5. 5
DUT-E SUM summator
enables to obtain data of
the total fuel volume from
several tanks of the vehicle
or from fixed tanks when
used in vehicles tracking
system / fuel monitoring
system
Cascade connection to
measure fuel volume in
three or more tanks is
possible
• .
7. 7
6000 mm
Additional section :
• DUТ-E length up to 6000 mm (for digital
sensor)
• Reduces the cost of delivery and stcoking
8. 8
200
220
240
260
280
300
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
-25 -15 -5 5 15 25 35 50 70
Built in thermocompensation
function allows to have stable
signal from DUT-E at different
temperature ranges from - 40
untill +85 ºС.
Fuel sensors with lack of
thermocompensation function
can have inaccuracy error of