CURRICULAM VITAE
Versatile Dynamic Proffessional with 19 years of progressive Experience and
proven Record of significant successful contribution in Electrical Commissioning,
Startup, Maintenance with Reputed Oil and Gas Industries in Middle East Region.
Confident of utilizing acqurired skills,knowledge and expertise across business
verticals in contributing to the achivement of corporate gols and objectives.
Name : E.SELVAM
Date of birth &Age : 02nd June 1974, 42yrs.
Nationality : INDIAN
Sex : Male, Marital status : Married
Technical Qualification : Diploma in Electrical and Electronics Engg.
(D.E.E.E) 1st class (Course Duration: 3Years)
(Course completed on April-1992)
Contact E-mail : selvame74@yahoo.com,
Passport No : L6068023. India.
: Expiry: 04-11-2023.
Address for communication : 3/41A, Kottur, Amoor-P.O,
Musiri-T.K, Trichy-D.T,
T.Nadu, India-621204.
Mobile : 0096897374108 - Oman
00919843235706 – India
Total Experience : 19 Years.
International Experience : 14 Years
Details of Employment (Starting from the recent employer)
Worked with Al-Hosn Gas Company(ADNOC Group of Company) at Abu Dhabi as
an Sr.Electrical Technician (Contract Hire).From Oct-2014 to Till Date.
Duties.
Coordinate and carryout the Testing and Commissioning Activities for ALL Plant
Electrical Equipments as per Project ITP. Worked as an AEP for switching Operations.
Prepare the switching program; revive the Drawings for Redline marked Up. Find out the
rout cause for breakdowns and rectify the problems during commissioning. Coordinate
with Vendors and supporting activities.
Carried out Inspection for Hazardous Ex Equipments Installations by verifying the
standards. Prepared the ITR’s for Ex Inspection. Implement the company HSSE policy at
site. Strictly Follow the Electrical Safety Rules and Instruct the colleagues and
subordinates to follow the same.
Presently working in Maintenance Department. Execute the day to day Maintenance
Activities of Preventive maintenance and Break down Maintenance. Trouble shooting of
Breakdown Equipments. Creating the notifications, Work orders, and Issuing the spare
parts from Ware house and create the new order for the spares Through SAP System.
Assess the subordinates and find out the Gaps where they required Training. I have well
knowledge in Ex Equipment Inspection and Maintenance.
_____________________________________________________________
I was working at AgipKCO,Kazakhstan (Through PRC Career Holdings) as an OGS
Electrical Supervisor, From 13th December 2012 to 9th October 2014.
Duties,
Coordinate and Support Activities for Commissioning and Startup of all kinds of
Plant Electrical Equipments.
Carried out Maintenance PM and CM of all Plant Electrical Equipments.
Troubleshooting and Route cause analysis for Breakdown Electrical Equipments.
Carried out safety audit at plant for safety of personnel and safe operation of Electrical
Equipments.
Check and maintain the Spare parts in the ware house, order the spares and
Create Notifications, Work orders, through SAP Blue Print system.
Attend time by time HSE Meetings and committed for Incident and Injury Free site, Goal
Zero.
I was working at Qatar SHELL GTL, as an Electrical Sr. Technician, From
June 23rd 2008 to 13 December 2012.
Duties.
Carried out Precommissioning and Commissioning activities for all substation and Field
Electrical Equipments of:
Transformers (Siemens and Brush) up to 40 MVA, 11 Kv Switch Gear (ABB), UPS up to
250Kva, Batteries, Motors up to 14.740 MW, VSD Motor 6.6Kv, 1455 Kw (Siemens).
Process heaters (2250 MW) and its control panel, Heat Tracing system control panel.LV
switchgear and 690v Motors.
Supervised the day to day activities of PM and CM. Generate work request, work orders,
settingpriorities, assigningsubordinates, Liaising with other operation and maintenance
supervisors to coordinate work activities. Endorsing work orders and work permits,
supervising the actual execution of work on site and in workshop. Investigates and
Troubleshoots maintenance problems and implement the company’s safe work
procedures. Liaises with the work planning personnel on timely updating of related
maintenance activities in SAP P49 System. Ensure that company HSE policies,
Procedures and Implemented and strictly adhered to in my area of responsibility.
Worked as Authorized Electrical Person (AEP), to carry out HV switching..
I have been undergone the Trainings on:
 CompEx Certified for EX-01, EX-02,EX-03,EX-04.
 Electrical Equipments at potential hazardous
 A1 work place Assessor training,
 Institute of Leadership and Management training,
 Frontline line Leadership training.
 First Aid training (Collage of North Atlantic Qatar),
 Vendor trainings on Electrical Equipments.
 IIF Trainings,
 Safety oriented Trainings.
 SAP Training and well working knowledge.
_____________________________________________________________________
Worked in TECNIMONT ICB LTD INDIA, as an Electrical Supervisor
(Commissioning) fromMarch-2007 to May 2008
Duties.
Co-Ordinate with Contractors, Vendors and Clients for Execution of Pre-
commissioning andcommissioning activities of Substation equipments and Field
electrical Equipments. Documentation,Modification and Up gradation of Drawings.
Worked in QATAR PETROCHEMICAL COMPANY, as Sr. Electrical Technician
(Behalf of Specialized Oil Services) from March-2005 to Dec 2006
Responsibilities.
I was one of the in charges for supervision and the coordination of actions about the
Plant Electrical Maintenance.
 Supervise the stock of relevant materials
 Define the competences and Qualification required on site.
- Examine the maintenance task
- Carry out the electrical consignment
Duties
Maintenance, Testing & commissioning, Trouble shooting of Transformers from to
500KVA to 25 MVA, and 33KV SF6 Gas Insulated Switch Gears, Frame 5 ALSTHOM
Gas Turbine Generator,20MW.
Maintenance and Trouble shooting of MV, LV motors, and its Control centers,
Protection Relays. (Merlin-GerinSEPEM-2000, and ABB Relays.)
Maintenance and Trouble shooting of Seawater Treatment (Chlorination) Units and its Power
Electronics Circuits.
Maintenance and Trouble shooting of UPS, Batteries and Battery Chargers.
______________________________________________________________________
Worked in ARABIAN PETROCHEMICAL COMPANY – PETROKEMYA
(SABIC) , as an Electrical Technician (Behalf of Hugayet, Jubail, Saudi Arabia.),
From 1st March 2003 to 31st December 2004.
Responsibilities.
 prepare the schedule for Materials, Tools, and Test Equipments for Preventive
Maintenance Activities of Plant equipments.
 Participate in Safety Talk Meetings (Every day).
 Involved in the Plant Turn Around activities and prepare the reports.
 Technical Reporting, and feed back to the Engineers.
Duties
Maintenance, Testing& commissioning, Troubleshooting of Transformers from to
500 KVA to 75 MVA (230/115kV, 115/34.5kV,. 34.5/4.16kV, 4.16/380v)
Maintenance and Troubleshooting of 230 kV, 115kV, 34.5kV SF6 Gas Insulated
SwitchGears and Protection Relays.(AEG,GEC-ALSTHOM,ABB,MERLIN-
GERIN,SIMENS Relays)
Maintenance and Trouble shooting of MV,LV Motors, control centers and its
Protection Relays,Lighting Distribution Panels and the Plant Lightings
Troubleshooting and find out the cable faults by using Marry loop tester and Cable
fault Locator.UPS and Batteries.
Worked in SUBIYA POWER PLANT-MEW -KUWAIT as an ELECTRICAL
FOREMAN (Behalf of Detchue Babcock Kuwait.), From 19th Dec 1998 to
31st August 2002
Nature of Jobs:
 Service, Repair and Maintain the Electrical parts and components on Company
and client owned equipment .
 Keep Records of All repairs and checks carried out Equipment.
 Repair and maintain all company owned Electrical Work shop tools in Good order
Keeping Records of Test Dates as required by.
 Correctly identify and Requisition Electrical Spares and Consumables as required
to meet the routine repairs on all company owned and managed equipment in a
timely manner.
 Carried out General Electrical Repairs and Maintenance on Electrical Equipments
and systems with in the scheduling the inspection routines to minimize down time
impact during normal working hours.
Worked In MADRAS REFINERIES LIMITED as an ELECTRICAL TECHNICIAN
from December 1994 to December 1998
Nature of Jobs:
Plant Electrical Equipment Maintenance. Carried out Preventive Maintenance, Trouble
shooting, repairing of Breakers, Transformers, L.V and H.V Motors, MCC Panels,
Relays, Lighting Distribution Panels, Emergency Diesel Generator control panels, UPS
and Battery chargers.
Transformer Testing includes PI value, TTR, Winding Resistance, and its Protections
Buchols Relay, Sudden pressure Relay, Pressure Relief Device, Temperature Gauges
(oil& Winding) and its cooling fans. Oil Treatment (Filtering by OTP Equipment)
Oil BDV Test and analyze the Lab Testing results of the Transformer Oil.
Switch Gear testing includes Breaker Testing of its IR value, Contact Resistance,
Opening Time &Closing Time, Lubricate the Mechanical Parts and test for the Protection
Relays.
Testing the motors for its abnormal sound during its operation and vibration test,
Overhauling, and IR value Winding Resistance and its Protections like Overload and
Earth faults.
Protection Relays Testing –Primary and secondary injection Tests by using the injection
test kits.
Cable faults Trouble shoot by using Cable fault locator.(Marry loop tester).
Worked in SIMCO ENGINEERING LIMITED at TRICHY, INDIA as an
APPRENTICE TRAINING. From 17-11-1992 to 16-11-1993
Nature of Jobs:
I Got the Act Apprentice Training In the Industrial Plant Electrical Maintenance of all
kinds of Electrical Equipments.
Details of Experience:
Installation, Testing &Commissioning, Troubleshooting, Predictive, Preventive and
Breakdown Maintenance of the following.
 Low voltage / Medium voltage Switchgear and Associated Breaker controls.
 ABB, SIEMENS, Merlin-Gerin, Mitsubishi, Powell, Larson & Toubro
(L&T), GEC-ALSTHOM
 High voltage 230/115/34.5 Kv (GIS) Switchgear and Associated Breaker
controls.
 Merlin-Gerin, Hitachi, Toshiba
 Transformers testing &commissioning, Trouble shooting from 500Kva to
75Mva Transformers (34.5kv/13.8kv/11kv/4.16kv/480v.)
 ABB, HUNDAI, FUGI, SAUDI TRANFORMERS, EMIRATES
BRUSH and SIEMENS TRANSFORMERS.
 Uninterruptible Power supplies (UPS and Battery chargers)
 GUTOR, SAFT, TATA-LIEBERT
 PLC controlled Electrical equipments Installation, testing& commissioning.
 SIMENS S5 (Mollers packaging equipment), FOXBORO
 SCADA control equipments Installation testing &commissioning.
 ABB (RTU), GE-HARRYS (D60, D20) Bay control units
 Sea Water Treatment (Chlorination Units) Power electronic controls
Maintenance and Trouble shooting
 Lighting and Distribution panels.
Safety Oriented Exposures:
 Attended H2S & Breathing Apparatus Training.
 Attend First aid course at Collage of North Atlantic Qatar.
 Reporting of Unsafe condition Reports, Quality Analysis Report,
Accident and Incident Report, Near Missing Report.
Special Assignments Exposures:
- Good inter personnel and communication skills.
- Discipline/hands on background in electrical area
- Good administrative and planning skills
- Good fluency in English knowledge.
 Modification / Improvement of Controls and up gradation of Safety related
Electrical Interlocks to match operating requirements and maintain reliability.
 Conversant with MS-OFFICE package.
 Conversant with adherence of Health, Safety and Environment Standards in
Petrochemical and Refinary plants.
 Vendor support activities and co-ordination at Plant site.
 Evaluation, suggestion, Immediate Corrective Actions, Feedback& Technical
Reporting.
 Fiber optic cable splicing, Termination and testing by optical power meters and
OTDR. (Training certificate from BRAND-REX, UK. Training held at Dubai.)
Yours Faithfully,
E.SELVAM.

Elangovan_Selvam (1)

  • 1.
    CURRICULAM VITAE Versatile DynamicProffessional with 19 years of progressive Experience and proven Record of significant successful contribution in Electrical Commissioning, Startup, Maintenance with Reputed Oil and Gas Industries in Middle East Region. Confident of utilizing acqurired skills,knowledge and expertise across business verticals in contributing to the achivement of corporate gols and objectives. Name : E.SELVAM Date of birth &Age : 02nd June 1974, 42yrs. Nationality : INDIAN Sex : Male, Marital status : Married Technical Qualification : Diploma in Electrical and Electronics Engg. (D.E.E.E) 1st class (Course Duration: 3Years) (Course completed on April-1992) Contact E-mail : selvame74@yahoo.com, Passport No : L6068023. India. : Expiry: 04-11-2023. Address for communication : 3/41A, Kottur, Amoor-P.O, Musiri-T.K, Trichy-D.T, T.Nadu, India-621204. Mobile : 0096897374108 - Oman 00919843235706 – India Total Experience : 19 Years. International Experience : 14 Years Details of Employment (Starting from the recent employer) Worked with Al-Hosn Gas Company(ADNOC Group of Company) at Abu Dhabi as an Sr.Electrical Technician (Contract Hire).From Oct-2014 to Till Date. Duties. Coordinate and carryout the Testing and Commissioning Activities for ALL Plant Electrical Equipments as per Project ITP. Worked as an AEP for switching Operations. Prepare the switching program; revive the Drawings for Redline marked Up. Find out the
  • 2.
    rout cause forbreakdowns and rectify the problems during commissioning. Coordinate with Vendors and supporting activities. Carried out Inspection for Hazardous Ex Equipments Installations by verifying the standards. Prepared the ITR’s for Ex Inspection. Implement the company HSSE policy at site. Strictly Follow the Electrical Safety Rules and Instruct the colleagues and subordinates to follow the same. Presently working in Maintenance Department. Execute the day to day Maintenance Activities of Preventive maintenance and Break down Maintenance. Trouble shooting of Breakdown Equipments. Creating the notifications, Work orders, and Issuing the spare parts from Ware house and create the new order for the spares Through SAP System. Assess the subordinates and find out the Gaps where they required Training. I have well knowledge in Ex Equipment Inspection and Maintenance. _____________________________________________________________ I was working at AgipKCO,Kazakhstan (Through PRC Career Holdings) as an OGS Electrical Supervisor, From 13th December 2012 to 9th October 2014. Duties, Coordinate and Support Activities for Commissioning and Startup of all kinds of Plant Electrical Equipments. Carried out Maintenance PM and CM of all Plant Electrical Equipments. Troubleshooting and Route cause analysis for Breakdown Electrical Equipments. Carried out safety audit at plant for safety of personnel and safe operation of Electrical Equipments. Check and maintain the Spare parts in the ware house, order the spares and Create Notifications, Work orders, through SAP Blue Print system. Attend time by time HSE Meetings and committed for Incident and Injury Free site, Goal Zero. I was working at Qatar SHELL GTL, as an Electrical Sr. Technician, From June 23rd 2008 to 13 December 2012. Duties. Carried out Precommissioning and Commissioning activities for all substation and Field Electrical Equipments of: Transformers (Siemens and Brush) up to 40 MVA, 11 Kv Switch Gear (ABB), UPS up to 250Kva, Batteries, Motors up to 14.740 MW, VSD Motor 6.6Kv, 1455 Kw (Siemens). Process heaters (2250 MW) and its control panel, Heat Tracing system control panel.LV switchgear and 690v Motors. Supervised the day to day activities of PM and CM. Generate work request, work orders, settingpriorities, assigningsubordinates, Liaising with other operation and maintenance supervisors to coordinate work activities. Endorsing work orders and work permits, supervising the actual execution of work on site and in workshop. Investigates and Troubleshoots maintenance problems and implement the company’s safe work procedures. Liaises with the work planning personnel on timely updating of related maintenance activities in SAP P49 System. Ensure that company HSE policies, Procedures and Implemented and strictly adhered to in my area of responsibility. Worked as Authorized Electrical Person (AEP), to carry out HV switching.. I have been undergone the Trainings on:  CompEx Certified for EX-01, EX-02,EX-03,EX-04.
  • 3.
     Electrical Equipmentsat potential hazardous  A1 work place Assessor training,  Institute of Leadership and Management training,  Frontline line Leadership training.  First Aid training (Collage of North Atlantic Qatar),  Vendor trainings on Electrical Equipments.  IIF Trainings,  Safety oriented Trainings.  SAP Training and well working knowledge. _____________________________________________________________________ Worked in TECNIMONT ICB LTD INDIA, as an Electrical Supervisor (Commissioning) fromMarch-2007 to May 2008 Duties. Co-Ordinate with Contractors, Vendors and Clients for Execution of Pre- commissioning andcommissioning activities of Substation equipments and Field electrical Equipments. Documentation,Modification and Up gradation of Drawings. Worked in QATAR PETROCHEMICAL COMPANY, as Sr. Electrical Technician (Behalf of Specialized Oil Services) from March-2005 to Dec 2006 Responsibilities. I was one of the in charges for supervision and the coordination of actions about the Plant Electrical Maintenance.  Supervise the stock of relevant materials  Define the competences and Qualification required on site. - Examine the maintenance task - Carry out the electrical consignment Duties Maintenance, Testing & commissioning, Trouble shooting of Transformers from to 500KVA to 25 MVA, and 33KV SF6 Gas Insulated Switch Gears, Frame 5 ALSTHOM Gas Turbine Generator,20MW. Maintenance and Trouble shooting of MV, LV motors, and its Control centers, Protection Relays. (Merlin-GerinSEPEM-2000, and ABB Relays.) Maintenance and Trouble shooting of Seawater Treatment (Chlorination) Units and its Power Electronics Circuits. Maintenance and Trouble shooting of UPS, Batteries and Battery Chargers. ______________________________________________________________________ Worked in ARABIAN PETROCHEMICAL COMPANY – PETROKEMYA (SABIC) , as an Electrical Technician (Behalf of Hugayet, Jubail, Saudi Arabia.), From 1st March 2003 to 31st December 2004. Responsibilities.  prepare the schedule for Materials, Tools, and Test Equipments for Preventive Maintenance Activities of Plant equipments.  Participate in Safety Talk Meetings (Every day).  Involved in the Plant Turn Around activities and prepare the reports.  Technical Reporting, and feed back to the Engineers.
  • 4.
    Duties Maintenance, Testing& commissioning,Troubleshooting of Transformers from to 500 KVA to 75 MVA (230/115kV, 115/34.5kV,. 34.5/4.16kV, 4.16/380v) Maintenance and Troubleshooting of 230 kV, 115kV, 34.5kV SF6 Gas Insulated SwitchGears and Protection Relays.(AEG,GEC-ALSTHOM,ABB,MERLIN- GERIN,SIMENS Relays) Maintenance and Trouble shooting of MV,LV Motors, control centers and its Protection Relays,Lighting Distribution Panels and the Plant Lightings Troubleshooting and find out the cable faults by using Marry loop tester and Cable fault Locator.UPS and Batteries. Worked in SUBIYA POWER PLANT-MEW -KUWAIT as an ELECTRICAL FOREMAN (Behalf of Detchue Babcock Kuwait.), From 19th Dec 1998 to 31st August 2002 Nature of Jobs:  Service, Repair and Maintain the Electrical parts and components on Company and client owned equipment .  Keep Records of All repairs and checks carried out Equipment.  Repair and maintain all company owned Electrical Work shop tools in Good order Keeping Records of Test Dates as required by.  Correctly identify and Requisition Electrical Spares and Consumables as required to meet the routine repairs on all company owned and managed equipment in a timely manner.  Carried out General Electrical Repairs and Maintenance on Electrical Equipments and systems with in the scheduling the inspection routines to minimize down time impact during normal working hours. Worked In MADRAS REFINERIES LIMITED as an ELECTRICAL TECHNICIAN from December 1994 to December 1998 Nature of Jobs: Plant Electrical Equipment Maintenance. Carried out Preventive Maintenance, Trouble shooting, repairing of Breakers, Transformers, L.V and H.V Motors, MCC Panels, Relays, Lighting Distribution Panels, Emergency Diesel Generator control panels, UPS and Battery chargers. Transformer Testing includes PI value, TTR, Winding Resistance, and its Protections Buchols Relay, Sudden pressure Relay, Pressure Relief Device, Temperature Gauges (oil& Winding) and its cooling fans. Oil Treatment (Filtering by OTP Equipment) Oil BDV Test and analyze the Lab Testing results of the Transformer Oil. Switch Gear testing includes Breaker Testing of its IR value, Contact Resistance, Opening Time &Closing Time, Lubricate the Mechanical Parts and test for the Protection Relays. Testing the motors for its abnormal sound during its operation and vibration test, Overhauling, and IR value Winding Resistance and its Protections like Overload and Earth faults. Protection Relays Testing –Primary and secondary injection Tests by using the injection test kits. Cable faults Trouble shoot by using Cable fault locator.(Marry loop tester). Worked in SIMCO ENGINEERING LIMITED at TRICHY, INDIA as an APPRENTICE TRAINING. From 17-11-1992 to 16-11-1993
  • 5.
    Nature of Jobs: IGot the Act Apprentice Training In the Industrial Plant Electrical Maintenance of all kinds of Electrical Equipments. Details of Experience: Installation, Testing &Commissioning, Troubleshooting, Predictive, Preventive and Breakdown Maintenance of the following.  Low voltage / Medium voltage Switchgear and Associated Breaker controls.  ABB, SIEMENS, Merlin-Gerin, Mitsubishi, Powell, Larson & Toubro (L&T), GEC-ALSTHOM  High voltage 230/115/34.5 Kv (GIS) Switchgear and Associated Breaker controls.  Merlin-Gerin, Hitachi, Toshiba  Transformers testing &commissioning, Trouble shooting from 500Kva to 75Mva Transformers (34.5kv/13.8kv/11kv/4.16kv/480v.)  ABB, HUNDAI, FUGI, SAUDI TRANFORMERS, EMIRATES BRUSH and SIEMENS TRANSFORMERS.  Uninterruptible Power supplies (UPS and Battery chargers)  GUTOR, SAFT, TATA-LIEBERT  PLC controlled Electrical equipments Installation, testing& commissioning.  SIMENS S5 (Mollers packaging equipment), FOXBORO  SCADA control equipments Installation testing &commissioning.  ABB (RTU), GE-HARRYS (D60, D20) Bay control units  Sea Water Treatment (Chlorination Units) Power electronic controls Maintenance and Trouble shooting  Lighting and Distribution panels. Safety Oriented Exposures:  Attended H2S & Breathing Apparatus Training.  Attend First aid course at Collage of North Atlantic Qatar.  Reporting of Unsafe condition Reports, Quality Analysis Report, Accident and Incident Report, Near Missing Report. Special Assignments Exposures: - Good inter personnel and communication skills. - Discipline/hands on background in electrical area - Good administrative and planning skills - Good fluency in English knowledge.  Modification / Improvement of Controls and up gradation of Safety related Electrical Interlocks to match operating requirements and maintain reliability.  Conversant with MS-OFFICE package.  Conversant with adherence of Health, Safety and Environment Standards in Petrochemical and Refinary plants.  Vendor support activities and co-ordination at Plant site.  Evaluation, suggestion, Immediate Corrective Actions, Feedback& Technical Reporting.  Fiber optic cable splicing, Termination and testing by optical power meters and OTDR. (Training certificate from BRAND-REX, UK. Training held at Dubai.) Yours Faithfully, E.SELVAM.