SlideShare a Scribd company logo
1 of 7
Colorado Golden Energy’s Extraction Steam Turbine Model
June 2012
CGE Extraction Steam Turbine Model
• CGE : a COGENERATION plant
– Simultaneous production of power and heat (50# and 400# steam)
– Max Efficiency when steam flows to condensers are minimized
 Higher extraction loads → Higher Plant Efficiency
 Best Efficiency when 50# loads are highest
– 400# and 50# Steam extracted from TG1 and TG2 to maintain 400# and 50#
header pressures
2
• A demand-driven model:
– User inputs are :
 400# & 50# extraction flows
 Power
– Splits the real turbine in 2 imaginary turbines
 An extraction-only turbine with no flow to condenser
 A straight-to-condenser turbine with no extraction
3
CGE Extraction Steam Turbine Model
• Extraction-Only Turbine Model:
– Mass Balance :
(i) f800 to extrac = f400 + f50
– Energy Balance :
Q800 to extrac = Q400 + Q50 + MWextrac
MWextrac = Q800 to extrac - Q400 - Q50
(ii) MWextrac = 0.9 x (H800 x f800 to extrac - H400 x f400 - H50 x f50)
“TG1 Ideal Load Equation” with 90% alternator efficiency to convert
mechanical energy to electricity.
4
CGE Extraction Steam Turbine Model
f800 to extrac, Q800 to extrac
f400 , Q400
f50 , Q50
MWextrac
• Straight-to-condenser Turbine Model:
– Energy Balance :
accounts for Power production in excess of “Ideal Load” produced by extraction-
only turbine
MWextra Dmnd = MWTotal Dmnd – MWextrac
MWextra Dmnd = Q800 to cond - Qcond
(iii) MWextra Dmnd = 0.9 x f800 to cond x (H800 - Hcond)
– Mass Balance :
(iv) f800 to cond = fcond
5
CGE Extraction Steam Turbine Model
f800 to cond, Q800 to cond
fcond, Qcond
MWextra Dmnd
• Recombined Turbine Model:
– Mass Balance :
f800 total = f800 to extrac + f800 to cond
f800 total = f400 + f50 + f800 to cond
– Energy Balance :
Q800 = Q800 to extrac + Q800 to cond
Q800 = Q400 + Q50 + MWextrac + MWextra Dmnd + Qcond
Q800 = H400 x f400 + H50 x f50 + MWtot + Hcond x fcond
Result :
a sensible and easy-to-implement set of formulas satisfying Mass, Energy Balances
6
CGE Extraction Steam Turbine Model
f800 totaL, Q800
f400 , Q400
f50 , Q50
MWtot
fcond, Qcond
• CGE : extraction loads and their impact on plant efficiency
– Impact on TG1’s thermal and electrical efficiency
7
75.00
80.00
85.00
90.00
95.00
100.00
0.75 0.77 0.79 0.81 0.83 0.85 0.87 0.89 0.91 0.93 0.95
Efficiency [%]
[(50# + 400#) Extraction / 800# Inlet] Ratio
TG1 - Efficiency vs [Extraction/Inlet] Ratio
Reality vs Model
CGE Extraction Steam Turbine Model

More Related Content

Similar to CGE_stm_model2

Cogeneration systems
Cogeneration systemsCogeneration systems
Cogeneration systemsrishabarani
 
Power_plant_ecomices.pptx
Power_plant_ecomices.pptxPower_plant_ecomices.pptx
Power_plant_ecomices.pptxLucasMogaka
 
Introduction to ppe
Introduction to ppeIntroduction to ppe
Introduction to ppeYash Shah
 
Efficiency and Heat Rate in cogenerative power system
Efficiency and Heat Rate in cogenerative power systemEfficiency and Heat Rate in cogenerative power system
Efficiency and Heat Rate in cogenerative power systemHashim Hasnain Hadi
 
CESC SGS project report
CESC SGS project reportCESC SGS project report
CESC SGS project reportSayanSarkar55
 
LAST up date for cv mohamed elsabagh.
LAST up date for cv mohamed elsabagh.LAST up date for cv mohamed elsabagh.
LAST up date for cv mohamed elsabagh.mohamed el sabagh
 
LAST up date for cv mohamed elsabagh.
LAST up date for cv mohamed elsabagh.LAST up date for cv mohamed elsabagh.
LAST up date for cv mohamed elsabagh.mohamed el sabagh
 
Chap 8: Internal Combustion Engine Power Plant
Chap 8: Internal Combustion Engine Power PlantChap 8: Internal Combustion Engine Power Plant
Chap 8: Internal Combustion Engine Power PlantMulugeta Wotango
 
Cogeneration project opportunity
Cogeneration project opportunityCogeneration project opportunity
Cogeneration project opportunityKittipass Wasinarom
 
Voith Offshore Solutions
Voith Offshore SolutionsVoith Offshore Solutions
Voith Offshore SolutionsAndrea Venora
 
27. COGENERATION.ppt
27. COGENERATION.ppt27. COGENERATION.ppt
27. COGENERATION.pptRENERGISTICS
 
Computer aided evaluation of steam power plants performance based on energy a...
Computer aided evaluation of steam power plants performance based on energy a...Computer aided evaluation of steam power plants performance based on energy a...
Computer aided evaluation of steam power plants performance based on energy a...Ahmed Noaman
 
17 Nov08 Campos Rodrigues
17 Nov08  Campos Rodrigues17 Nov08  Campos Rodrigues
17 Nov08 Campos Rodriguesh2portugal
 
Proceedings of ASME Turbo Expo 2010 Final
Proceedings of ASME Turbo Expo 2010 FinalProceedings of ASME Turbo Expo 2010 Final
Proceedings of ASME Turbo Expo 2010 FinalGary Williams
 

Similar to CGE_stm_model2 (20)

Cogeneration systems
Cogeneration systemsCogeneration systems
Cogeneration systems
 
Power_plant_ecomices.pptx
Power_plant_ecomices.pptxPower_plant_ecomices.pptx
Power_plant_ecomices.pptx
 
Introduction to ppe
Introduction to ppeIntroduction to ppe
Introduction to ppe
 
Efficiency and Heat Rate in cogenerative power system
Efficiency and Heat Rate in cogenerative power systemEfficiency and Heat Rate in cogenerative power system
Efficiency and Heat Rate in cogenerative power system
 
Numericals.pptx .
Numericals.pptx                                 .Numericals.pptx                                 .
Numericals.pptx .
 
CESC SGS project report
CESC SGS project reportCESC SGS project report
CESC SGS project report
 
LAST up date for cv mohamed elsabagh.
LAST up date for cv mohamed elsabagh.LAST up date for cv mohamed elsabagh.
LAST up date for cv mohamed elsabagh.
 
LAST up date for cv mohamed elsabagh.
LAST up date for cv mohamed elsabagh.LAST up date for cv mohamed elsabagh.
LAST up date for cv mohamed elsabagh.
 
Chap 8: Internal Combustion Engine Power Plant
Chap 8: Internal Combustion Engine Power PlantChap 8: Internal Combustion Engine Power Plant
Chap 8: Internal Combustion Engine Power Plant
 
Epa of cogen
Epa of cogenEpa of cogen
Epa of cogen
 
Cogeneration project opportunity
Cogeneration project opportunityCogeneration project opportunity
Cogeneration project opportunity
 
X10694 (me8391)
X10694 (me8391)X10694 (me8391)
X10694 (me8391)
 
Voith Offshore Solutions
Voith Offshore SolutionsVoith Offshore Solutions
Voith Offshore Solutions
 
CHP Proposal
CHP ProposalCHP Proposal
CHP Proposal
 
27. COGENERATION.ppt
27. COGENERATION.ppt27. COGENERATION.ppt
27. COGENERATION.ppt
 
Computer aided evaluation of steam power plants performance based on energy a...
Computer aided evaluation of steam power plants performance based on energy a...Computer aided evaluation of steam power plants performance based on energy a...
Computer aided evaluation of steam power plants performance based on energy a...
 
17 Nov08 Campos Rodrigues
17 Nov08  Campos Rodrigues17 Nov08  Campos Rodrigues
17 Nov08 Campos Rodrigues
 
CHTZ
CHTZCHTZ
CHTZ
 
Proceedings of ASME Turbo Expo 2010 Final
Proceedings of ASME Turbo Expo 2010 FinalProceedings of ASME Turbo Expo 2010 Final
Proceedings of ASME Turbo Expo 2010 Final
 
X10699 (me8493)
X10699 (me8493)X10699 (me8493)
X10699 (me8493)
 

CGE_stm_model2

  • 1. Colorado Golden Energy’s Extraction Steam Turbine Model June 2012
  • 2. CGE Extraction Steam Turbine Model • CGE : a COGENERATION plant – Simultaneous production of power and heat (50# and 400# steam) – Max Efficiency when steam flows to condensers are minimized  Higher extraction loads → Higher Plant Efficiency  Best Efficiency when 50# loads are highest – 400# and 50# Steam extracted from TG1 and TG2 to maintain 400# and 50# header pressures 2
  • 3. • A demand-driven model: – User inputs are :  400# & 50# extraction flows  Power – Splits the real turbine in 2 imaginary turbines  An extraction-only turbine with no flow to condenser  A straight-to-condenser turbine with no extraction 3 CGE Extraction Steam Turbine Model
  • 4. • Extraction-Only Turbine Model: – Mass Balance : (i) f800 to extrac = f400 + f50 – Energy Balance : Q800 to extrac = Q400 + Q50 + MWextrac MWextrac = Q800 to extrac - Q400 - Q50 (ii) MWextrac = 0.9 x (H800 x f800 to extrac - H400 x f400 - H50 x f50) “TG1 Ideal Load Equation” with 90% alternator efficiency to convert mechanical energy to electricity. 4 CGE Extraction Steam Turbine Model f800 to extrac, Q800 to extrac f400 , Q400 f50 , Q50 MWextrac
  • 5. • Straight-to-condenser Turbine Model: – Energy Balance : accounts for Power production in excess of “Ideal Load” produced by extraction- only turbine MWextra Dmnd = MWTotal Dmnd – MWextrac MWextra Dmnd = Q800 to cond - Qcond (iii) MWextra Dmnd = 0.9 x f800 to cond x (H800 - Hcond) – Mass Balance : (iv) f800 to cond = fcond 5 CGE Extraction Steam Turbine Model f800 to cond, Q800 to cond fcond, Qcond MWextra Dmnd
  • 6. • Recombined Turbine Model: – Mass Balance : f800 total = f800 to extrac + f800 to cond f800 total = f400 + f50 + f800 to cond – Energy Balance : Q800 = Q800 to extrac + Q800 to cond Q800 = Q400 + Q50 + MWextrac + MWextra Dmnd + Qcond Q800 = H400 x f400 + H50 x f50 + MWtot + Hcond x fcond Result : a sensible and easy-to-implement set of formulas satisfying Mass, Energy Balances 6 CGE Extraction Steam Turbine Model f800 totaL, Q800 f400 , Q400 f50 , Q50 MWtot fcond, Qcond
  • 7. • CGE : extraction loads and their impact on plant efficiency – Impact on TG1’s thermal and electrical efficiency 7 75.00 80.00 85.00 90.00 95.00 100.00 0.75 0.77 0.79 0.81 0.83 0.85 0.87 0.89 0.91 0.93 0.95 Efficiency [%] [(50# + 400#) Extraction / 800# Inlet] Ratio TG1 - Efficiency vs [Extraction/Inlet] Ratio Reality vs Model CGE Extraction Steam Turbine Model