Calculate the theoretical power in kW to 1 DP developed by a fluid motor. The formula is: theoretical power = VolumetricDisplacement * AngularSpeed * pressure where the volumetric displacement = 122 cubic centimeters / revolution, the AngularSpeed = 1,242 rpm, and the pressure = 120 bar. 1 bar = 100,000 N/m^2, 1 m = 100 cm, and 1 kW = 1000 N*m/s Solution theoretical power = VolumetricDisplacement * AngularSpeed * pressure = 122/100^3 * 1,242/60 *120*10000 =181828.8/60Nm/sec =3.0304kW.