SlideShare a Scribd company logo
Gas Extinguishing
Warning Indicatior
C-9318

Technical Specifications
•
•
•
•
•
•
•
•
•

Features and Benefits
1.
2.
3.
4.
5.

Normally installed above the entrance
to a gas extinguishing control area.
Will eliminate and activate internal
sounder prior to gas release.
"Gas Extinguishing DO NOT ENTER" is
printed on the panel of the indicator.
Highlight LED
Compatible with GST series of gas
extinguishing control panel

Operating voltage: 24Vdc (20Vdc to
28Vdc) polarized
Operating Current: Alarm: 100mA
Operating temperature: -10°C to
+50°C
Relative humidity: 95%
Indicators: 16 Highlights Red LED,
constantly lit when alarm
Application: Indoor use
Material and colour: ABS, Red
Wiring: 1 pair polarized
Dimensions: 280m×110mm×46mm

Wiring and Connection
Connect the wires to the required terminal
according to the diagram. The cable must
be fire rated type and the size depends on
the distance and application. Minimum size
gauge 1.0mm²(18 AWG). See installation
and operation for more information.

1 PAIR FIRE CABLE

Selection of compatible Control Panels
Compatible with all GST Conventional and
Addressable
Gas
Extinguishing
Control
System.

GAS
EXTINGUISHING
CONTROL PANEL

XT2

WARNING INDICATOR A

Gas
XT1

DO NOT

WARNING INDICATOR B

G1, R1 (XT1): To DC24V or GND, R
terminal
of
extinguishing
control panel, polarized.
G2, R2 (XT2): Connecting with gas
extinguishing
warning
indicator in series
or with
4.7kΩresistor.
Ordering Information:
Part No

C-9318

Description

Gas
Extinguishing
Warning
Indicator

Weight
/Kg

0.850

XT2

G2 R2

XT1

G1 R1

Gas

DO NOT

G2 R2

C-9318 Gas Extinguishing Warning Indicator
is the accessory equipment of a gas
extinguishing system. It's usually installed at
the entrance of the protected area. After gas
is released, the controller will activate the
indicator to give visual indication warning
people in field to take relative measures.
This indicator is non-addressable and is used
together with extinguishing control panel.

G1 R1

Description

Pack
Qty
per
Box
1

Note: Specifications are subject to change without notice.

More Related Content

What's hot

IGBT Based Static Voltage Regulator
IGBT Based Static Voltage RegulatorIGBT Based Static Voltage Regulator
IGBT Based Static Voltage Regulator
Kirk Patel
 
CMA10YT900D SPEC
CMA10YT900D  SPECCMA10YT900D  SPEC
CMA10YT900D SPEC
HT-TECH CORPORATION
 
DIN Rail Mount Tachometer for Process Measurement and Control
DIN Rail Mount Tachometer for Process Measurement and ControlDIN Rail Mount Tachometer for Process Measurement and Control
DIN Rail Mount Tachometer for Process Measurement and Control
Analynk Wireless, LLC
 
Magnetostrictive level transmitter added to magnetic level gauge
Magnetostrictive level transmitter added to magnetic level gaugeMagnetostrictive level transmitter added to magnetic level gauge
Magnetostrictive level transmitter added to magnetic level gauge
Alliance Technical Sales, Inc.
 
Laser based level transmitter for industrial process measurement
Laser based level transmitter for industrial process measurementLaser based level transmitter for industrial process measurement
Laser based level transmitter for industrial process measurement
Alliance Technical Sales, Inc.
 
PTP35
PTP35PTP35
CMA10YT750D SPEC
CMA10YT750D  SPECCMA10YT750D  SPEC
CMA10YT750D SPEC
HT-TECH CORPORATION
 
Catalog mikro mikro mk203a-dienhathe.vn
Catalog mikro mikro mk203a-dienhathe.vnCatalog mikro mikro mk203a-dienhathe.vn
Catalog mikro mikro mk203a-dienhathe.vn
Dien Ha The
 
Msr adt-03-3430-benzene-gas-sensor
Msr adt-03-3430-benzene-gas-sensorMsr adt-03-3430-benzene-gas-sensor
Msr adt-03-3430-benzene-gas-sensor
ALVI Automation - GasAlarm India
 
CMA10YT600D SPEC
CMA10YT600D  SPECCMA10YT600D  SPEC
CMA10YT600D SPEC
HT-TECH CORPORATION
 
CMA10YT900E SPEC
CMA10YT900E  SPECCMA10YT900E  SPEC
CMA10YT900E SPEC
HT-TECH CORPORATION
 
Htc digital multimeter dm 88
Htc digital multimeter dm 88Htc digital multimeter dm 88
Htc digital multimeter dm 88
Monarch Controls
 
Head Mounted Temperature Transmitter
Head Mounted Temperature TransmitterHead Mounted Temperature Transmitter
Head Mounted Temperature Transmitter
NK Instruments Pvt. Ltd.
 
Radar Level Transmitter for Liquids
Radar Level Transmitter for LiquidsRadar Level Transmitter for Liquids
Radar Level Transmitter for Liquids
NK Instruments Pvt. Ltd.
 
Radar Level Transmitter for Solids
Radar Level Transmitter for SolidsRadar Level Transmitter for Solids
Radar Level Transmitter for Solids
NK Instruments Pvt. Ltd.
 
constant current led triac dimming driver
constant current led triac dimming driverconstant current led triac dimming driver
constant current led triac dimming driver
Shanghai Euchips Industrial Co.,Ltd.
 
CMA05YT900D SPEC
CMA05YT900D  SPECCMA05YT900D  SPEC
CMA05YT900D SPEC
HT-TECH CORPORATION
 
FSR05KT6R8 SPEC 20141219
FSR05KT6R8 SPEC 20141219FSR05KT6R8 SPEC 20141219
FSR05KT6R8 SPEC 20141219
HTTECHCORPORATION
 
DTT35
DTT35DTT35
CMA05YT900E SPEC
CMA05YT900E  SPECCMA05YT900E  SPEC
CMA05YT900E SPEC
HT-TECH CORPORATION
 

What's hot (20)

IGBT Based Static Voltage Regulator
IGBT Based Static Voltage RegulatorIGBT Based Static Voltage Regulator
IGBT Based Static Voltage Regulator
 
CMA10YT900D SPEC
CMA10YT900D  SPECCMA10YT900D  SPEC
CMA10YT900D SPEC
 
DIN Rail Mount Tachometer for Process Measurement and Control
DIN Rail Mount Tachometer for Process Measurement and ControlDIN Rail Mount Tachometer for Process Measurement and Control
DIN Rail Mount Tachometer for Process Measurement and Control
 
Magnetostrictive level transmitter added to magnetic level gauge
Magnetostrictive level transmitter added to magnetic level gaugeMagnetostrictive level transmitter added to magnetic level gauge
Magnetostrictive level transmitter added to magnetic level gauge
 
Laser based level transmitter for industrial process measurement
Laser based level transmitter for industrial process measurementLaser based level transmitter for industrial process measurement
Laser based level transmitter for industrial process measurement
 
PTP35
PTP35PTP35
PTP35
 
CMA10YT750D SPEC
CMA10YT750D  SPECCMA10YT750D  SPEC
CMA10YT750D SPEC
 
Catalog mikro mikro mk203a-dienhathe.vn
Catalog mikro mikro mk203a-dienhathe.vnCatalog mikro mikro mk203a-dienhathe.vn
Catalog mikro mikro mk203a-dienhathe.vn
 
Msr adt-03-3430-benzene-gas-sensor
Msr adt-03-3430-benzene-gas-sensorMsr adt-03-3430-benzene-gas-sensor
Msr adt-03-3430-benzene-gas-sensor
 
CMA10YT600D SPEC
CMA10YT600D  SPECCMA10YT600D  SPEC
CMA10YT600D SPEC
 
CMA10YT900E SPEC
CMA10YT900E  SPECCMA10YT900E  SPEC
CMA10YT900E SPEC
 
Htc digital multimeter dm 88
Htc digital multimeter dm 88Htc digital multimeter dm 88
Htc digital multimeter dm 88
 
Head Mounted Temperature Transmitter
Head Mounted Temperature TransmitterHead Mounted Temperature Transmitter
Head Mounted Temperature Transmitter
 
Radar Level Transmitter for Liquids
Radar Level Transmitter for LiquidsRadar Level Transmitter for Liquids
Radar Level Transmitter for Liquids
 
Radar Level Transmitter for Solids
Radar Level Transmitter for SolidsRadar Level Transmitter for Solids
Radar Level Transmitter for Solids
 
constant current led triac dimming driver
constant current led triac dimming driverconstant current led triac dimming driver
constant current led triac dimming driver
 
CMA05YT900D SPEC
CMA05YT900D  SPECCMA05YT900D  SPEC
CMA05YT900D SPEC
 
FSR05KT6R8 SPEC 20141219
FSR05KT6R8 SPEC 20141219FSR05KT6R8 SPEC 20141219
FSR05KT6R8 SPEC 20141219
 
DTT35
DTT35DTT35
DTT35
 
CMA05YT900E SPEC
CMA05YT900E  SPECCMA05YT900E  SPEC
CMA05YT900E SPEC
 

Viewers also liked

Gst301
Gst301Gst301
Gst301
Adit Group
 
C 9317
C 9317C 9317
C 9317
Adit Group
 
Pulse amplitude modulation
Pulse amplitude modulationPulse amplitude modulation
Pulse amplitude modulation
Vishal kakade
 
Contaminación ambiental diapositivas para mandar ok
Contaminación ambiental diapositivas para mandar okContaminación ambiental diapositivas para mandar ok
Contaminación ambiental diapositivas para mandar ok
floritzelareyesestrada
 
Taller 1
Taller 1Taller 1
Taller 1
Yoneider Lesmes
 
Reflexiones
ReflexionesReflexiones
Selección de tecnología educativa
Selección de tecnología educativa Selección de tecnología educativa
Selección de tecnología educativa
hermosa2612
 
Gerdau - II Encontro Ações da Rede
Gerdau - II Encontro Ações da RedeGerdau - II Encontro Ações da Rede
Gerdau - II Encontro Ações da Rede
brunofukasawa
 
Entegable fase 1 ok
Entegable fase 1 okEntegable fase 1 ok
Entegable fase 1 ok
marthaadelaida
 
Tipos de empresas copia
Tipos de empresas   copiaTipos de empresas   copia
Tipos de empresas copia
luiskjaimesf
 
Instituto tegnologico yola
Instituto tegnologico yolaInstituto tegnologico yola
Instituto tegnologico yola
yolandacando1
 
Evidencias de natalia tello y jessica velasco !!
Evidencias de natalia tello y jessica velasco !!Evidencias de natalia tello y jessica velasco !!
Evidencias de natalia tello y jessica velasco !!
ficha320890
 
I te c construmat 2011
I te c construmat 2011I te c construmat 2011
Características de la información para la Gestión
Características de la información para la GestiónCaracterísticas de la información para la Gestión
Características de la información para la Gestión
caferreras49
 
Euroconstruct smopyc i te c 3_04_2014
Euroconstruct smopyc i te c 3_04_2014Euroconstruct smopyc i te c 3_04_2014
Euroconstruct smopyc i te c 3_04_2014
ITeC Instituto Tecnología Construcción
 
Tema 2
Tema 2Tema 2
Presentación Rocío Dúrcal
Presentación Rocío DúrcalPresentación Rocío Dúrcal
Presentación Rocío Dúrcal
MarianneGarnier
 
Historia de la evolucion
Historia de la evolucion Historia de la evolucion
Historia de la evolucion
jcentenocevallos
 
Uqp i te_c_2012_oct
Uqp i te_c_2012_octUqp i te_c_2012_oct
Expresión oral y escrita
Expresión oral y escrita Expresión oral y escrita
Expresión oral y escrita
michellealejandra17
 

Viewers also liked (20)

Gst301
Gst301Gst301
Gst301
 
C 9317
C 9317C 9317
C 9317
 
Pulse amplitude modulation
Pulse amplitude modulationPulse amplitude modulation
Pulse amplitude modulation
 
Contaminación ambiental diapositivas para mandar ok
Contaminación ambiental diapositivas para mandar okContaminación ambiental diapositivas para mandar ok
Contaminación ambiental diapositivas para mandar ok
 
Taller 1
Taller 1Taller 1
Taller 1
 
Reflexiones
ReflexionesReflexiones
Reflexiones
 
Selección de tecnología educativa
Selección de tecnología educativa Selección de tecnología educativa
Selección de tecnología educativa
 
Gerdau - II Encontro Ações da Rede
Gerdau - II Encontro Ações da RedeGerdau - II Encontro Ações da Rede
Gerdau - II Encontro Ações da Rede
 
Entegable fase 1 ok
Entegable fase 1 okEntegable fase 1 ok
Entegable fase 1 ok
 
Tipos de empresas copia
Tipos de empresas   copiaTipos de empresas   copia
Tipos de empresas copia
 
Instituto tegnologico yola
Instituto tegnologico yolaInstituto tegnologico yola
Instituto tegnologico yola
 
Evidencias de natalia tello y jessica velasco !!
Evidencias de natalia tello y jessica velasco !!Evidencias de natalia tello y jessica velasco !!
Evidencias de natalia tello y jessica velasco !!
 
I te c construmat 2011
I te c construmat 2011I te c construmat 2011
I te c construmat 2011
 
Características de la información para la Gestión
Características de la información para la GestiónCaracterísticas de la información para la Gestión
Características de la información para la Gestión
 
Euroconstruct smopyc i te c 3_04_2014
Euroconstruct smopyc i te c 3_04_2014Euroconstruct smopyc i te c 3_04_2014
Euroconstruct smopyc i te c 3_04_2014
 
Tema 2
Tema 2Tema 2
Tema 2
 
Presentación Rocío Dúrcal
Presentación Rocío DúrcalPresentación Rocío Dúrcal
Presentación Rocío Dúrcal
 
Historia de la evolucion
Historia de la evolucion Historia de la evolucion
Historia de la evolucion
 
Uqp i te_c_2012_oct
Uqp i te_c_2012_octUqp i te_c_2012_oct
Uqp i te_c_2012_oct
 
Expresión oral y escrita
Expresión oral y escrita Expresión oral y escrita
Expresión oral y escrita
 

Similar to C 9318

C 9103
C 9103C 9103
C 9103
Adit Group
 
T switch - att11-endress+hauser datasheet-thermal flow switch
T switch - att11-endress+hauser datasheet-thermal flow switchT switch - att11-endress+hauser datasheet-thermal flow switch
T switch - att11-endress+hauser datasheet-thermal flow switch
ENVIMART
 
C 9104
C 9104C 9104
C 9104
Adit Group
 
Gst rp16
Gst rp16Gst rp16
Gst rp16
Adit Group
 
9101
91019101
Monicon brochure
Monicon brochureMonicon brochure
Monicon brochure
a1-cbiss
 
C 9202
C 9202C 9202
C 9202
Adit Group
 
Detectomat Fire Alarm Systems in India by Monsher
Detectomat Fire Alarm Systems in India by MonsherDetectomat Fire Alarm Systems in India by Monsher
Detectomat Fire Alarm Systems in India by Monsher
monsher123
 
C 9317
C 9317C 9317
C 9317
Adit Group
 
RIVPF_GB_LOCAL
RIVPF_GB_LOCALRIVPF_GB_LOCAL
RIVPF_GB_LOCAL
Palani Samy
 
9103
91039103
Gst108 116 1
Gst108 116 1Gst108 116 1
Gst108 116 1
Adit Group
 
Gst108 116
Gst108 116Gst108 116
Gst108 116
Adit Group
 
4903-0010 - Conventional Strobe with Horn.pdf
4903-0010 - Conventional Strobe with Horn.pdf4903-0010 - Conventional Strobe with Horn.pdf
4903-0010 - Conventional Strobe with Horn.pdf
SourovSamadder
 
C 9401
C 9401C 9401
C 9401
Adit Group
 
Electronic units and systems for armored vehicles
Electronic units and systems for armored vehiclesElectronic units and systems for armored vehicles
Electronic units and systems for armored vehicles
Andrew Diakoniuk
 
LEDGEAR one4all ENEC approved driver specification
LEDGEAR one4all ENEC approved driver specificationLEDGEAR one4all ENEC approved driver specification
LEDGEAR one4all ENEC approved driver specification
Hendy C. -Lighting & Control
 
Micro e systems_mte_ds_datasheet
Micro e systems_mte_ds_datasheetMicro e systems_mte_ds_datasheet
Micro e systems_mte_ds_datasheet
Electromate
 
Firelaser-datasheet-SenseTek Glasvezel detectie
Firelaser-datasheet-SenseTek  Glasvezel detectieFirelaser-datasheet-SenseTek  Glasvezel detectie
Firelaser-datasheet-SenseTek Glasvezel detectie
Hans Bronkhorst
 
Gst fire alarm system ver.2010
Gst fire alarm system ver.2010Gst fire alarm system ver.2010
Gst fire alarm system ver.2010
WallaceNgai
 

Similar to C 9318 (20)

C 9103
C 9103C 9103
C 9103
 
T switch - att11-endress+hauser datasheet-thermal flow switch
T switch - att11-endress+hauser datasheet-thermal flow switchT switch - att11-endress+hauser datasheet-thermal flow switch
T switch - att11-endress+hauser datasheet-thermal flow switch
 
C 9104
C 9104C 9104
C 9104
 
Gst rp16
Gst rp16Gst rp16
Gst rp16
 
9101
91019101
9101
 
Monicon brochure
Monicon brochureMonicon brochure
Monicon brochure
 
C 9202
C 9202C 9202
C 9202
 
Detectomat Fire Alarm Systems in India by Monsher
Detectomat Fire Alarm Systems in India by MonsherDetectomat Fire Alarm Systems in India by Monsher
Detectomat Fire Alarm Systems in India by Monsher
 
C 9317
C 9317C 9317
C 9317
 
RIVPF_GB_LOCAL
RIVPF_GB_LOCALRIVPF_GB_LOCAL
RIVPF_GB_LOCAL
 
9103
91039103
9103
 
Gst108 116 1
Gst108 116 1Gst108 116 1
Gst108 116 1
 
Gst108 116
Gst108 116Gst108 116
Gst108 116
 
4903-0010 - Conventional Strobe with Horn.pdf
4903-0010 - Conventional Strobe with Horn.pdf4903-0010 - Conventional Strobe with Horn.pdf
4903-0010 - Conventional Strobe with Horn.pdf
 
C 9401
C 9401C 9401
C 9401
 
Electronic units and systems for armored vehicles
Electronic units and systems for armored vehiclesElectronic units and systems for armored vehicles
Electronic units and systems for armored vehicles
 
LEDGEAR one4all ENEC approved driver specification
LEDGEAR one4all ENEC approved driver specificationLEDGEAR one4all ENEC approved driver specification
LEDGEAR one4all ENEC approved driver specification
 
Micro e systems_mte_ds_datasheet
Micro e systems_mte_ds_datasheetMicro e systems_mte_ds_datasheet
Micro e systems_mte_ds_datasheet
 
Firelaser-datasheet-SenseTek Glasvezel detectie
Firelaser-datasheet-SenseTek  Glasvezel detectieFirelaser-datasheet-SenseTek  Glasvezel detectie
Firelaser-datasheet-SenseTek Glasvezel detectie
 
Gst fire alarm system ver.2010
Gst fire alarm system ver.2010Gst fire alarm system ver.2010
Gst fire alarm system ver.2010
 

More from Adit Group

Seccall receiver1
Seccall receiver1Seccall receiver1
Seccall receiver1Adit Group
 
Seccall receiver
Seccall receiverSeccall receiver
Seccall receiverAdit Group
 
Bl wt transmitter-wireless
Bl wt transmitter-wirelessBl wt transmitter-wireless
Bl wt transmitter-wirelessAdit Group
 
Bl wr60-wireless-receiver
Bl wr60-wireless-receiverBl wr60-wireless-receiver
Bl wr60-wireless-receiverAdit Group
 
Bl rm20-call-expander
Bl rm20-call-expanderBl rm20-call-expander
Bl rm20-call-expanderAdit Group
 
Seccall receiver2
Seccall receiver2Seccall receiver2
Seccall receiver2Adit Group
 

More from Adit Group (20)

Od z220
Od z220Od z220
Od z220
 
Od z219
Od z219Od z219
Od z219
 
Od z217
Od z217Od z217
Od z217
 
Od z218
Od z218Od z218
Od z218
 
Bliss pdf
Bliss pdfBliss pdf
Bliss pdf
 
Odwm104
Odwm104Odwm104
Odwm104
 
Od wc115
Od wc115Od wc115
Od wc115
 
Od pp01
Od pp01Od pp01
Od pp01
 
Seccall receiver1
Seccall receiver1Seccall receiver1
Seccall receiver1
 
Seccall receiver
Seccall receiverSeccall receiver
Seccall receiver
 
Bl wt transmitter-wireless
Bl wt transmitter-wirelessBl wt transmitter-wireless
Bl wt transmitter-wireless
 
Bl wr60-wireless-receiver
Bl wr60-wireless-receiverBl wr60-wireless-receiver
Bl wr60-wireless-receiver
 
Bl rm20-call-expander
Bl rm20-call-expanderBl rm20-call-expander
Bl rm20-call-expander
 
Seccall receiver2
Seccall receiver2Seccall receiver2
Seccall receiver2
 
Od tc45
Od tc45Od tc45
Od tc45
 
Od hsd46
Od hsd46Od hsd46
Od hsd46
 
Od du43
Od du43Od du43
Od du43
 
Od du33
Od du33Od du33
Od du33
 
Od du13
Od du13Od du13
Od du13
 
Od cu42
Od cu42Od cu42
Od cu42
 

C 9318

  • 1. Gas Extinguishing Warning Indicatior C-9318 Technical Specifications • • • • • • • • • Features and Benefits 1. 2. 3. 4. 5. Normally installed above the entrance to a gas extinguishing control area. Will eliminate and activate internal sounder prior to gas release. "Gas Extinguishing DO NOT ENTER" is printed on the panel of the indicator. Highlight LED Compatible with GST series of gas extinguishing control panel Operating voltage: 24Vdc (20Vdc to 28Vdc) polarized Operating Current: Alarm: 100mA Operating temperature: -10°C to +50°C Relative humidity: 95% Indicators: 16 Highlights Red LED, constantly lit when alarm Application: Indoor use Material and colour: ABS, Red Wiring: 1 pair polarized Dimensions: 280m×110mm×46mm Wiring and Connection Connect the wires to the required terminal according to the diagram. The cable must be fire rated type and the size depends on the distance and application. Minimum size gauge 1.0mm²(18 AWG). See installation and operation for more information. 1 PAIR FIRE CABLE Selection of compatible Control Panels Compatible with all GST Conventional and Addressable Gas Extinguishing Control System. GAS EXTINGUISHING CONTROL PANEL XT2 WARNING INDICATOR A Gas XT1 DO NOT WARNING INDICATOR B G1, R1 (XT1): To DC24V or GND, R terminal of extinguishing control panel, polarized. G2, R2 (XT2): Connecting with gas extinguishing warning indicator in series or with 4.7kΩresistor. Ordering Information: Part No C-9318 Description Gas Extinguishing Warning Indicator Weight /Kg 0.850 XT2 G2 R2 XT1 G1 R1 Gas DO NOT G2 R2 C-9318 Gas Extinguishing Warning Indicator is the accessory equipment of a gas extinguishing system. It's usually installed at the entrance of the protected area. After gas is released, the controller will activate the indicator to give visual indication warning people in field to take relative measures. This indicator is non-addressable and is used together with extinguishing control panel. G1 R1 Description Pack Qty per Box 1 Note: Specifications are subject to change without notice.