Aditgroup present the different fire alarm detector for the security purpose. Here user gets the Duel Heat detector, Manual call point, Smoke Alarm, Optical smoke detector etc.
The DI-9104Exd is an explosion-proof UV flame detector that features a single chip microcomputer for signal processing and communication control. It has an intelligent algorithm for fast alarm response and superior false alarm rejection. The detector connects directly to GST addressable loops and is compatible with all GST intelligent panels. It has three sensitivity levels and is high sensitive, reliable, and resistant to dust, corrosion, and humidity. The detector is adapted for use in explosive areas 1 and 2.
Aditgroup present the different fire alarm detector for the security purpose. Here user gets the Duel Heat detector, Manual call point, Smoke Alarm, Optical smoke detector etc.
Ceasefire provides wireless fire alarm systems including smoke detectors, control panels, sirens, and repeaters to detect fires quickly. The smoke detectors use photoelectric sensors to detect smoke and have features like battery life indicators. The control panel collects data from various sensors and identifies events to report to monitoring stations. Wireless sirens provide loud alarms in multiple locations. Repeaters extend the range of communication between devices. Standalone alarms also quickly detect smoke with features like escape lights and long battery life.
Aditgroup present the different fire alarm detector for the security purpose. Here user gets the Duel Heat detector, Manual call point, Smoke Alarm, Optical smoke detector etc.
The C-9101Ex explosion proof combined heat and photoelectric smoke detector has several key features:
1. It can detect smoke and heat in hazardous areas requiring explosion proof equipment, and connects to fire alarm panels and devices via an I-9332Ex interface module.
2. The detector has a dust proof sensing chamber, low profile design, LEDs for 360 degree visibility, and operates between -10 to 40 degrees Celsius.
3. It is installed using a standard electrical box and compatible with GST fire alarm panels, interfaces, detectors, and call points for processing alarm signals.
The Dräger Polytron IR CO2 is a gas detector that uses infrared technology to continuously monitor carbon dioxide levels. It has various features like fast and accurate response, adjustable measurement ranges from 2000 ppm to 30% by volume, and is suitable for use in explosive atmospheres. It comes in different versions, including standard, remote display, and hand-held terminal versions. It provides maximum safety and system availability when combined with a suitable controller.
This document describes an optical beam security system that uses a laser, light dependent resistor, comparator, microcontroller, buzzer, and GSM module. It works by detecting interruptions in the laser beam pointed at the light dependent resistor, which causes the resistor's resistance to fall and the comparator output to trigger the microcontroller. The microcontroller then sounds the buzzer and sends a message via GSM to alert the owner of the intrusion. Block diagrams, component specifications, circuit diagrams, working principles, and applications are provided.
The DI-9104Exd is an explosion-proof UV flame detector that features a single chip microcomputer for signal processing and communication control. It has an intelligent algorithm for fast alarm response and superior false alarm rejection. The detector connects directly to GST addressable loops and is compatible with all GST intelligent panels. It has three sensitivity levels and is high sensitive, reliable, and resistant to dust, corrosion, and humidity. The detector is adapted for use in explosive areas 1 and 2.
Aditgroup present the different fire alarm detector for the security purpose. Here user gets the Duel Heat detector, Manual call point, Smoke Alarm, Optical smoke detector etc.
Ceasefire provides wireless fire alarm systems including smoke detectors, control panels, sirens, and repeaters to detect fires quickly. The smoke detectors use photoelectric sensors to detect smoke and have features like battery life indicators. The control panel collects data from various sensors and identifies events to report to monitoring stations. Wireless sirens provide loud alarms in multiple locations. Repeaters extend the range of communication between devices. Standalone alarms also quickly detect smoke with features like escape lights and long battery life.
Aditgroup present the different fire alarm detector for the security purpose. Here user gets the Duel Heat detector, Manual call point, Smoke Alarm, Optical smoke detector etc.
The C-9101Ex explosion proof combined heat and photoelectric smoke detector has several key features:
1. It can detect smoke and heat in hazardous areas requiring explosion proof equipment, and connects to fire alarm panels and devices via an I-9332Ex interface module.
2. The detector has a dust proof sensing chamber, low profile design, LEDs for 360 degree visibility, and operates between -10 to 40 degrees Celsius.
3. It is installed using a standard electrical box and compatible with GST fire alarm panels, interfaces, detectors, and call points for processing alarm signals.
The Dräger Polytron IR CO2 is a gas detector that uses infrared technology to continuously monitor carbon dioxide levels. It has various features like fast and accurate response, adjustable measurement ranges from 2000 ppm to 30% by volume, and is suitable for use in explosive atmospheres. It comes in different versions, including standard, remote display, and hand-held terminal versions. It provides maximum safety and system availability when combined with a suitable controller.
This document describes an optical beam security system that uses a laser, light dependent resistor, comparator, microcontroller, buzzer, and GSM module. It works by detecting interruptions in the laser beam pointed at the light dependent resistor, which causes the resistor's resistance to fall and the comparator output to trigger the microcontroller. The microcontroller then sounds the buzzer and sends a message via GSM to alert the owner of the intrusion. Block diagrams, component specifications, circuit diagrams, working principles, and applications are provided.
The Hochiki ACD-V is a multi-sensor device that detects smoke, heat, and carbon monoxide. It has a low profile, supports various operational modes, and uses digital communication to provide fast response times. The sensor uses light scattering to detect smoke and thermistors to detect heat, while a separate cell detects carbon monoxide levels. It can be installed securely using a locking base and is compatible with Hochiki fire alarm control panels.
The InnovairFlex D4120 duct smoke detector features a flexible housing that fits both square and rectangular ducts. It operates in air velocities from 100 to 4,000 feet per minute and temperatures from -4°F to 158°F with 0-95% humidity. The plug-in sensor head offers improved false alarm immunity and maintenance. Up to 50 detectors can be interconnected to isolate the fire source location.
The Dräger Flame 5000 is a standalone explosion proof flame detector that uses color imaging and digital signal processing to detect fires as small as 0.1 m2 at 44 meters. It has a 90 degree field of view and can integrate with control systems using 4-20mA or relay outputs. The detector provides live video, records before and after alarms, and has worldwide safety approvals.
The D-9107RExd is a digital, explosion proof, dual infrared flame detector that uses dual band infrared detection to reliably detect flames while being immune to artificial lights and heat radiation. It has both addressable and conventional functions, can be electronically addressed by a handheld programmer, and is suitable for hazardous industrial and civil applications involving explosive environments or flammable dust.
This document provides a product list for fire alarm solutions, including conventional fire alarm panels with 2-16 zones, addressable fire alarm panels, detectors, manual call points, bases, modules, audio-visual devices, accessories, and software. The conventional panels include models with metal or plastic enclosures and fixed or expandable zones. The addressable panel, IRIS, supports up to 4 loops with various expansion and programming options. A variety of detectors, call points, and modules are included to interface with the panels.
The document discusses NFPA 72 and NFPA 101, which provide minimum requirements for fire alarm systems and life safety from fire. NFPA 72 defines signal initiation, transmission, notification and annunciation for fire alarm systems to provide notification, summon aid and control safety functions. NFPA 101 aims to protect occupants from initial fire development and improve survivability for those near the fire. The document outlines requirements for visible signaling, including candela ratings and placement of strobes in corridors and sleeping areas. Synchronization of multiple appliances is also addressed.
This document summarizes the specifications and use of a dual passive infrared curtain detector used for security alarms. It detects movement within an adjustable range of 2 to 9 meters at an 15 degree angle. When motion is detected, it automatically sends an alarm signal to the alarm host. It is suitable for security in homes, offices, warehouses and other buildings.
The document discusses the evolution and capabilities of modern security systems. It notes that early security systems were basic and difficult to install, but that technology has made systems smarter, more reliable and put more control in the hands of homeowners. Modern systems can detect intrusions and dangers, alert homeowners and emergency services, and be controlled remotely through internet or cell phone. The document outlines some common electronic security devices like surveillance cameras, fire alarms, intruder alarms, and electronic locks. It provides details on how these systems work and have advanced with technology.
Aditgroup present the different fire alarm detector for the security purpose. Here user gets the Duel Heat detector, Manual call point, Smoke Alarm, Optical smoke detector etc.
This document provides an overview of fire alarm system fundamentals based on current NFPA codes. It defines key components of fire alarm systems including the fire alarm control panel, initiating devices, notification appliances, transmitters and receivers, and control functions. It also outlines the classification of fire alarm systems, why they are installed, and what topics will be covered, including a review of NFPA 72.
The InnovairFlex D2 2-wire photoelectric duct smoke detector has a pivoting housing that fits both square and rectangular ducts. It senses airflow from 100-4,000 feet per minute and has improved resistance to false alarms. The detector's modular design simplifies installation and maintenance in harsh duct environments. Accessories include remote test stations and annunciators for flexible system integration.
EN54-7 Compliance Commercial Fire Alarm System.
Using microprocessor technology with memory capacity up to 10 events
The TX7100 Intelligent Addressable Optical Smoke Detector is the ideal device for most applications,due to its spiffing linear response to a wide variety of different types of smoke patterns. The unitmanufactured the sensitivity requirement of EN 54 part 7, European Standard.
The Dräger Flame 2300 is an explosion proof combined UV/IR flame detector that can detect hydrocarbon fires. It has a flexible design with multiple output and installation options. It is reliable in detecting fires with high immunity to false alarms by requiring both UV and IR sensors to detect a fire. It is approved for worldwide use under various certifications.
This document provides installation and operation instructions for the Fibaro Smoke Sensor. It includes:
1) Details on how to include the sensor in a Z-Wave network either automatically or manually and exclude it from the network.
2) An overview of the sensor's operation modes, smoke and temperature detection functionality, and ability to detect lack of Z-Wave range.
3) Guidelines for installing the sensor properly and configuring its sensitivity level.
www.sensetek.nl
Branddetectie | Aspiratiesystemen | Thermische kabelsystemen | Beamdetectie | Vlamdetectie | Vloeistofdetectie | Voedingen | Proefbrandmateriaal
Specificaties voor het kleinste ASD systeem van Kidde Airsense. Stratos Nano aspiratiedetectie. Bel voor informatie naar de adviseurs van SenseTek. of kijk op de website
De FireLaser is het hart van het branddetectiesysteem. Glasvezeltechniek kent een grote vlucht in brandbeveiliging. SenseTek is de distributeur van Bandweaver glasvezel branddetectie. Het systeem voldoet aan de Nederlandse wetgevingen en eisen. Het systeem heeft dan ook de EN54-22 keur. Juist voor grotere projecten alsook parkeergarages is deze glasvezeltechniek een efficiënte oplossing. SenseTek is specialist op het gebied van branddetectie. vraag vrijblijvend naar de voordelen van glasvezel. www.sensetek.nl sales@sensetek.nl of 020-6131611
The document discusses the Dräger Polytron 5720 stationary gas detector. It has an innovative infrared sensor design that offers short response times, low sensitivity to dust/dirt, and a drift-free output signal. It can monitor carbon dioxide in ambient air and has optional relays to control external equipment based on gas concentration alarms. The Polytron 5720 is part of Dräger's Polytron 5000 series of gas detectors that have a uniform design and operating philosophy.
Smokeless Flares
Smokeless flares incinerate flammable hazardous vent gas with the assistance of supplemental high-velocity air or steam to prevent the formation of soot or smoke. Excessive injection of air or steam reduces combustion efficiency, resulting in the release of hazardous VOC gases. Meanwhile, inadequate injection of air or steam results in the formation of undesirable soot and smoke. Although modern flares are designed for high flow rates associated with an emergency condition, they most commonly operate at high-turn-down, low-flow rates, making it challenging for the flare to operate at optimal combustion efficiency.
Pilot Monitor
Flammable vent gases are ignited by a pilot flame when released into the atmosphere by refineries, natural gas processing plants, and petrochemical plants. The proper incineration of these gases is a critical safety and environmental concern. Therefore, it is essential to confirm that the pilot is lit at all times. Monitoring via a thermocouple is common, however, failures frequently occur and replacements can require costly process shutdowns. Remote sensing IR technology (PM) is the superior alternative.
Flame Intensity Monitors
Williamson Flame Intensity Monitors (FI) are the single-wavelength sensors of choice for a variety of flare applications where the more sophisticated dual-wavelength flare products are not appropriate or are not required.
The document discusses fire alarm system fundamentals and requirements based on NFPA 70 and NFPA 72 standards. Key points include requirements for initiating devices to be compatible with listed control units, emergency functions not interfering with alarm operations, alarm activation within 10 seconds of detection, and zoning, annunciation, monitoring, and limitations of fire alarm systems and components.
Aditgroup present the different fire alarm detector for the security purpose. Here user gets the Duel Heat detector, Manual call point, Smoke Alarm, Optical smoke detector etc.
The Sensepoint Pro is a fixed gas detector that provides comprehensive monitoring of flammable, toxic, and oxygen gas hazards both indoors and outdoors. It can be configured and adjusted remotely without opening the unit using an intrinsically safe remote control. This enables one-person, non-intrusive operation and reduces maintenance time and costs. The Sensepoint Pro comes with all necessary accessories for easy installation and is suitable for wall or pole mounting.
The Hochiki ACD-V is a multi-sensor device that detects smoke, heat, and carbon monoxide. It has a low profile, supports various operational modes, and uses digital communication to provide fast response times. The sensor uses light scattering to detect smoke and thermistors to detect heat, while a separate cell detects carbon monoxide levels. It can be installed securely using a locking base and is compatible with Hochiki fire alarm control panels.
The InnovairFlex D4120 duct smoke detector features a flexible housing that fits both square and rectangular ducts. It operates in air velocities from 100 to 4,000 feet per minute and temperatures from -4°F to 158°F with 0-95% humidity. The plug-in sensor head offers improved false alarm immunity and maintenance. Up to 50 detectors can be interconnected to isolate the fire source location.
The Dräger Flame 5000 is a standalone explosion proof flame detector that uses color imaging and digital signal processing to detect fires as small as 0.1 m2 at 44 meters. It has a 90 degree field of view and can integrate with control systems using 4-20mA or relay outputs. The detector provides live video, records before and after alarms, and has worldwide safety approvals.
The D-9107RExd is a digital, explosion proof, dual infrared flame detector that uses dual band infrared detection to reliably detect flames while being immune to artificial lights and heat radiation. It has both addressable and conventional functions, can be electronically addressed by a handheld programmer, and is suitable for hazardous industrial and civil applications involving explosive environments or flammable dust.
This document provides a product list for fire alarm solutions, including conventional fire alarm panels with 2-16 zones, addressable fire alarm panels, detectors, manual call points, bases, modules, audio-visual devices, accessories, and software. The conventional panels include models with metal or plastic enclosures and fixed or expandable zones. The addressable panel, IRIS, supports up to 4 loops with various expansion and programming options. A variety of detectors, call points, and modules are included to interface with the panels.
The document discusses NFPA 72 and NFPA 101, which provide minimum requirements for fire alarm systems and life safety from fire. NFPA 72 defines signal initiation, transmission, notification and annunciation for fire alarm systems to provide notification, summon aid and control safety functions. NFPA 101 aims to protect occupants from initial fire development and improve survivability for those near the fire. The document outlines requirements for visible signaling, including candela ratings and placement of strobes in corridors and sleeping areas. Synchronization of multiple appliances is also addressed.
This document summarizes the specifications and use of a dual passive infrared curtain detector used for security alarms. It detects movement within an adjustable range of 2 to 9 meters at an 15 degree angle. When motion is detected, it automatically sends an alarm signal to the alarm host. It is suitable for security in homes, offices, warehouses and other buildings.
The document discusses the evolution and capabilities of modern security systems. It notes that early security systems were basic and difficult to install, but that technology has made systems smarter, more reliable and put more control in the hands of homeowners. Modern systems can detect intrusions and dangers, alert homeowners and emergency services, and be controlled remotely through internet or cell phone. The document outlines some common electronic security devices like surveillance cameras, fire alarms, intruder alarms, and electronic locks. It provides details on how these systems work and have advanced with technology.
Aditgroup present the different fire alarm detector for the security purpose. Here user gets the Duel Heat detector, Manual call point, Smoke Alarm, Optical smoke detector etc.
This document provides an overview of fire alarm system fundamentals based on current NFPA codes. It defines key components of fire alarm systems including the fire alarm control panel, initiating devices, notification appliances, transmitters and receivers, and control functions. It also outlines the classification of fire alarm systems, why they are installed, and what topics will be covered, including a review of NFPA 72.
The InnovairFlex D2 2-wire photoelectric duct smoke detector has a pivoting housing that fits both square and rectangular ducts. It senses airflow from 100-4,000 feet per minute and has improved resistance to false alarms. The detector's modular design simplifies installation and maintenance in harsh duct environments. Accessories include remote test stations and annunciators for flexible system integration.
EN54-7 Compliance Commercial Fire Alarm System.
Using microprocessor technology with memory capacity up to 10 events
The TX7100 Intelligent Addressable Optical Smoke Detector is the ideal device for most applications,due to its spiffing linear response to a wide variety of different types of smoke patterns. The unitmanufactured the sensitivity requirement of EN 54 part 7, European Standard.
The Dräger Flame 2300 is an explosion proof combined UV/IR flame detector that can detect hydrocarbon fires. It has a flexible design with multiple output and installation options. It is reliable in detecting fires with high immunity to false alarms by requiring both UV and IR sensors to detect a fire. It is approved for worldwide use under various certifications.
This document provides installation and operation instructions for the Fibaro Smoke Sensor. It includes:
1) Details on how to include the sensor in a Z-Wave network either automatically or manually and exclude it from the network.
2) An overview of the sensor's operation modes, smoke and temperature detection functionality, and ability to detect lack of Z-Wave range.
3) Guidelines for installing the sensor properly and configuring its sensitivity level.
www.sensetek.nl
Branddetectie | Aspiratiesystemen | Thermische kabelsystemen | Beamdetectie | Vlamdetectie | Vloeistofdetectie | Voedingen | Proefbrandmateriaal
Specificaties voor het kleinste ASD systeem van Kidde Airsense. Stratos Nano aspiratiedetectie. Bel voor informatie naar de adviseurs van SenseTek. of kijk op de website
De FireLaser is het hart van het branddetectiesysteem. Glasvezeltechniek kent een grote vlucht in brandbeveiliging. SenseTek is de distributeur van Bandweaver glasvezel branddetectie. Het systeem voldoet aan de Nederlandse wetgevingen en eisen. Het systeem heeft dan ook de EN54-22 keur. Juist voor grotere projecten alsook parkeergarages is deze glasvezeltechniek een efficiënte oplossing. SenseTek is specialist op het gebied van branddetectie. vraag vrijblijvend naar de voordelen van glasvezel. www.sensetek.nl sales@sensetek.nl of 020-6131611
The document discusses the Dräger Polytron 5720 stationary gas detector. It has an innovative infrared sensor design that offers short response times, low sensitivity to dust/dirt, and a drift-free output signal. It can monitor carbon dioxide in ambient air and has optional relays to control external equipment based on gas concentration alarms. The Polytron 5720 is part of Dräger's Polytron 5000 series of gas detectors that have a uniform design and operating philosophy.
Smokeless Flares
Smokeless flares incinerate flammable hazardous vent gas with the assistance of supplemental high-velocity air or steam to prevent the formation of soot or smoke. Excessive injection of air or steam reduces combustion efficiency, resulting in the release of hazardous VOC gases. Meanwhile, inadequate injection of air or steam results in the formation of undesirable soot and smoke. Although modern flares are designed for high flow rates associated with an emergency condition, they most commonly operate at high-turn-down, low-flow rates, making it challenging for the flare to operate at optimal combustion efficiency.
Pilot Monitor
Flammable vent gases are ignited by a pilot flame when released into the atmosphere by refineries, natural gas processing plants, and petrochemical plants. The proper incineration of these gases is a critical safety and environmental concern. Therefore, it is essential to confirm that the pilot is lit at all times. Monitoring via a thermocouple is common, however, failures frequently occur and replacements can require costly process shutdowns. Remote sensing IR technology (PM) is the superior alternative.
Flame Intensity Monitors
Williamson Flame Intensity Monitors (FI) are the single-wavelength sensors of choice for a variety of flare applications where the more sophisticated dual-wavelength flare products are not appropriate or are not required.
The document discusses fire alarm system fundamentals and requirements based on NFPA 70 and NFPA 72 standards. Key points include requirements for initiating devices to be compatible with listed control units, emergency functions not interfering with alarm operations, alarm activation within 10 seconds of detection, and zoning, annunciation, monitoring, and limitations of fire alarm systems and components.
Aditgroup present the different fire alarm detector for the security purpose. Here user gets the Duel Heat detector, Manual call point, Smoke Alarm, Optical smoke detector etc.
The Sensepoint Pro is a fixed gas detector that provides comprehensive monitoring of flammable, toxic, and oxygen gas hazards both indoors and outdoors. It can be configured and adjusted remotely without opening the unit using an intrinsically safe remote control. This enables one-person, non-intrusive operation and reduces maintenance time and costs. The Sensepoint Pro comes with all necessary accessories for easy installation and is suitable for wall or pole mounting.
Aditgroup present the different fire alarm detector for the security purpose. Here user gets the Duel Heat detector, Manual call point, Smoke Alarm, Optical smoke detector etc.
This document provides information on fire alarm panels, detectors, and accessories for conventional and 2-wire fire alarm systems. It describes the components, including panels with various zone and circuit capacities, smoke and heat detectors, sounders, call points, and accessories. Diagrams show typical wiring for conventional and 2-wire system configurations.
This document describes an IR flame detector model RIV-601P/F and RIV-601P/FA. It provides specifications for the detectors such as operating voltage, current draw, alarm delay time, output relay, temperature range, dimensions, approvals. The RIV-601P/FA model adds an explosion-proof enclosure. Accessories include variable direction stands for adjusting the detector angle horizontally and vertically.
Aditgroup present the different fire alarm detector for the security purpose. Here user gets the Duel Heat detector, Manual call point, Smoke Alarm, Optical smoke detector etc.
The document describes the Fire-Lite InnovairFlex D355PL(A) and DNRW intelligent non-relay photoelectric duct smoke detectors. The detectors feature a pivoting housing that fits both square and rectangular ducts and can mount to round or rectangular ducts. The DNRW model has a NEMA-4 rating making it watertight and UV resistant for extreme environments. The detectors operate in airflows from 100-4000 feet per minute, temperatures from -4°F to 158°F, and humidity from 0-95%. Accessories include remote test stations and accessories for visible and audible annunciation.
This document provides specifications and instructions for the I-9319 intelligent zone monitor unit. The unit allows conventional fire detection devices like smoke detectors and manual call points to be integrated into an addressable fire alarm system. It monitors the connected conventional devices for alarms and faults and communicates their status to the fire alarm control panel. The unit has an LED indicator and is installed using a mounting base onto an electrical back box. Wiring involves connecting the unit to the fire detection loop, power supply, and conventional devices. Programming is done using a handheld programmer to set the unit's electronic address.
The C-9103Ex explosion proof dual heat detector features fixed temperature and rate-of-rise detection using a twin LED for 360 degree visibility. It operates between -10 to 40 degrees Celsius at 12-24V DC with low current draw and IP53 enclosure protection. The detector connects to an I-9332Ex interface module to interface with fire alarm panels and can monitor areas up to 30 square meters in height up to 8 meters.
Aditgroup present the different fire alarm detector for the security purpose. Here user gets the Duel Heat detector, Manual call point, Smoke Alarm, Optical smoke detector etc.
This document describes a digital explosion-proof reflective beam detector. It integrates the emitting and receiving parts for easy installation and alignment. It has built-in intelligence to judge fire alarms and faults, and can self-diagnose while compensating for factors like dust, movement, and aging components. It can be used for both addressable and conventional systems through electrical addressing or a handheld programmer.
The C-9318 Gas Extinguishing Warning Indicator provides visual warning that a gas extinguishing system has been activated. It features a red LED that lights continuously after gas is released from the compatible GST gas extinguishing control panel. Installed at entrances, it alerts people not to enter the protected area with the message "Gas Extinguishing DO NOT ENTER". Powered by 24VDC, it connects in series with other indicators or a resistor for non-addressable operation with a gas extinguishing control system.
The RAY 3000 is an infrared optical beam smoke detector that uses separate transmitter and receiver heads to detect smoke across large, open spaces. It is designed for high ceilings and areas where access for ceiling detectors is difficult. The detector offers adjustable sensitivity levels and alignment via thumbwheels or an optional adjustment bracket. It is suitable for modern architectural buildings as well as heritage sites due to its aesthetically pleasing design.
GST is a leading fire alarm system provider in China. It was founded in 1993 and has become the largest provider in China by market share and sales revenue. UTC Fire & Security acquired a stake in GST in 2006 and fully merged with the company in 2009 to provide comprehensive fire safety solutions globally under various brands including GST. GST manufactures over 7 million detectors and 30,000 control panels annually, applying strict quality standards. It has obtained certification from various international bodies and has a global product distribution network.
The document describes the specifications of the Sokkia CX Series of compact total station instruments. The CX Series offers high-accuracy angle and distance measurements along with long battery life of up to 36 hours. Key features include RED-tech reflectorless EDM, long range data communication via Bluetooth, advanced angle measurement systems, and a rugged waterproof design suitable for various job sites. The document provides detailed technical specifications for different CX Series models including measurement capabilities, interface options, and accessories.
Discover the Beauty and Functionality of The Expert Remodeling Serviceobriengroupinc04
Unlock your kitchen's true potential with expert remodeling services from O'Brien Group Inc. Transform your space into a functional, modern, and luxurious haven with their experienced professionals. From layout reconfiguration to high-end upgrades, they deliver stunning results tailored to your style and needs. Visit obriengroupinc.com to elevate your kitchen's beauty and functionality today.
Satta matka fixx jodi panna all market dpboss matka guessing fixx panna jodi kalyan and all market game liss cover now 420 matka office mumbai maharashtra india fixx jodi panna
Call me 9040963354
WhatsApp 9040963354
IMPACT Silver is a pure silver zinc producer with over $260 million in revenue since 2008 and a large 100% owned 210km Mexico land package - 2024 catalysts includes new 14% grade zinc Plomosas mine and 20,000m of fully funded exploration drilling.
Call8328958814 satta matka Kalyan result satta guessing➑➌➋➑➒➎➑➑➊➍
Satta Matka Kalyan Main Mumbai Fastest Results
Satta Matka ❋ Sattamatka ❋ New Mumbai Ratan Satta Matka ❋ Fast Matka ❋ Milan Market ❋ Kalyan Matka Results ❋ Satta Game ❋ Matka Game ❋ Satta Matka ❋ Kalyan Satta Matka ❋ Mumbai Main ❋ Online Matka Results ❋ Satta Matka Tips ❋ Milan Chart ❋ Satta Matka Boss❋ New Star Day ❋ Satta King ❋ Live Satta Matka Results ❋ Satta Matka Company ❋ Indian Matka ❋ Satta Matka 143❋ Kalyan Night Matka..
Best Competitive Marble Pricing in Dubai - ☎ 9928909666Stone Art Hub
Stone Art Hub offers the best competitive Marble Pricing in Dubai, ensuring affordability without compromising quality. With a wide range of exquisite marble options to choose from, you can enhance your spaces with elegance and sophistication. For inquiries or orders, contact us at ☎ 9928909666. Experience luxury at unbeatable prices.
AI Transformation Playbook: Thinking AI-First for Your BusinessArijit Dutta
I dive into how businesses can stay competitive by integrating AI into their core processes. From identifying the right approach to building collaborative teams and recognizing common pitfalls, this guide has got you covered. AI transformation is a journey, and this playbook is here to help you navigate it successfully.
Unveiling the Dynamic Personalities, Key Dates, and Horoscope Insights: Gemin...my Pandit
Explore the fascinating world of the Gemini Zodiac Sign. Discover the unique personality traits, key dates, and horoscope insights of Gemini individuals. Learn how their sociable, communicative nature and boundless curiosity make them the dynamic explorers of the zodiac. Dive into the duality of the Gemini sign and understand their intellectual and adventurous spirit.
Storytelling is an incredibly valuable tool to share data and information. To get the most impact from stories there are a number of key ingredients. These are based on science and human nature. Using these elements in a story you can deliver information impactfully, ensure action and drive change.
1. Conventional
Ultraviolet Flame
C-9104
Features:
1.
2.
3.
4.
5.
6.
7.
Technical Specifications
•
•
•
Protection rating: IP 32
Operating voltage: 24Vdc
Operating Current:
Standby current 1.5mA
Alarm Current 10mA
Operating temp:-10°C to +50°C
Relative humidity: 95%
Application: Indoor use
Detection angle: 80 degree
Visual Indicator: LED, Red ( lit steady
when alarm
Material and colour: ABS, off-white
Wiring: 1 pair polarized
Dimensions: diameter 10cm; height
5cm
EMBEDDED BOX
CONCRETE PAD OR
HOLDING PAD
MARK−LINE
2ND MARK−LINE
LED INDICATOR
ROTATE CLOCKWISE
Wiring and Connection
Connect the wires to the required terminal
according to the wire diagram with
matching active end of line (P-9907).and
(DZ-03D) required base is The cable must
be fire rated type and the size depends on
the distance and application. Minimum size
gauge 1.0mm²(18 AWG)
CONVENTIONAL
PANEL
OR
+
The C-9104 Conventional Ultraviolet Flames
Detector is fast and capable to detecting the
ultraviolet (UV) rays emitted by a burning
substance and is used in high hazard
applications such as petrochemical plants,
munitions factories and other areas where
flammable or explosive liquids or solids are
handled or stored. The C-9104 sensor adopts
an ultraviolet photosensitive tube, with
qualities of highly sensitive, reliable, dustresistant, corrosion-proof and moistureresistant, therefore is not sensitive in sunlight,
dust, oil, tolerance of fume, and humidity.
•
•
•
•
•
Detector Installation
The combination of fire detection should be
installed complied with all local codes and /
or NFPA 72 National Fire Alarm Code, NFPA
70 National Electrical Code. Verify the
proper wiring and base is firmly mounted to
prevent detector damage before the
installation. Point the detector in the base
by the mark-line and secure the detector in
that position by rotates it clockwise until it
reaches the next mark line.
Not sensitive by sunlight
Dust /corrosion/humidity resistance
Secure and speedy communication
Standard calibration set to detect a
3cm flame at 6metres
Effective range 12 metres
110º effective detection dispersion
angle
Twin LED for 360º vision
Description:
•
•
•
Selection of compatible Control Panels
Compatible with all GST Conventional panel
and GST Intelligent Fire Alarm Panels using
Zone monitor module:
ZONE
MONITOR
MODULE
−
1
2
1
2
1
4
3
4
3
4
2
3
P−9907 ACTIVE
END OF LINE
C−9102 SMOKE DETECTOR
C−9101 SMOKE/HEAT DETECTOR
Ordering Information:
Part No
C-9104
DZ-03
DZ-03D
Description
Weight
/Kg
Conventional
Ultraviolet
Flame
Detector
Detector Base -EOLR
Base with Diode AOL
0.123
Pack
Qty per
Box
120
0.05
0.05
360
360
MANUFACTURED IN ACCORDANCE WITH
Note: Specifications are subject to change without notice.