Nanofiltration is a pressure-driven membrane purification process whose characteristics
fall between those of ultrafiltration (UF) and reverse osmosis (RO, also called
hyperfiltration). See sidebar: Figure 1. Particle Size Scale.
NF is also called low-pressure RO. Its membranes remove particles and small dissolved
molecules and ions, usually hardness, iron, organics or color.
Typical NF applications include water softening, desalination of dyestuffs, acid and
caustic recovery, and color removal.
The NF membrane
An NF membrane works just like an RO membrane. The separation process for NF
requires that the water be forced through a semi-permeable membrane in the opposite
direction of natural osmotic flow, leaving contaminants in the more highly concentration
solution (reject water).
Nanofiltration membranes usually have three layers: a high-strength polyester base
(approximately 150 microns thick), a microporous polysulfone interlayer (approximately
50 microns thick), and an ultra-thin polyamide barrier layer on the top surface (0.2
micron thick) See sidebar: Figure 2. NF Membrane Layers.
NF membranes are mostly packed in a spiral-wound configuration. This configuration
offers lower replacement costs and a simpler plumbing system, as well as easier
maintenance and greater design freedom compared with tubular and flat plate designs.
A cross-flow process is carried out by having a process solution or feedwater flow along
a membrane surface under pressure. Cross-flow membrane filtration uses a high cross-
flow rate to enhance permeate passage and to reduce membrane fouling. Retained
solutes (such as dissolved salts) leave with the flowing process stream and do not
accumulate on the membrane surface.
Within the system
Basic spiral-wound element construction makes use of flat sheet membrane cast onto a
support fabric. The flat sheet membrane is enclosed between layers of feed spacer and
permeate carrier. This process forms a leaf, which is sealed at each edge.
Many leaves are rolled into a cylinder around a perforated central tube. Finished
element diameters can be in a range of 2.5” to 18” with a length up to 60” (see sidebar:
Figure 3. NF Membrane Elements).
Standard test conditions for an NF element usually include feedwater, temperature,
pressure, pH and recovery. The simplest NF system for POU/POE consists of a
prefilter, an NF membrane filter, a booster pump, a storage tank for the treated water,
and a flow regulator for the reject water, just like any RO system design.
Nanofiltration is a low- to moderately high-pressure (typically 50 to 450 pounds per
square inch [psi]) process in which monovalent ions will pass freely through the
membrane but highly charged, multi-valent salts and low molecular weight organic
molecules will be rejected to a much greater degree (see sidebar: Table 1. NF and RO
Rejection Rates, Parameters).
NF and RO: Similarities, differences
Comparisons of NF with RO can be generally highlighted as followed:
 Both are RO technology. The NF membrane is just a little “looser” — that is, RO
will remove smaller-diameter particles than NF.
 The key difference is the degree of removal of monovalent ions such as
chlorides. RO removes monovalent ions at the 98 to 99 percent level at 200 psi.
NF removal of monovalent ions varies between 10 and 90 percent, depending on
the material and manufacture of the membrane.
 In general, RO has less flow (produces less volume) than NF.
 NF and RO are generally in the spiral-wound configuration.
 RO membranes are characterized by high rejection of TDS (total dissolved
solids) in the range of 98 to 99.5 percent.
 NF membranes are characterized by higher water permeability than the RO
membranes and lower TDS rejection.
 NF membranes have sufficiently high rejection of selected constituents, i.e.,
hardness, metals (iron) and organic matter.
 Membrane fouling: A high concentration of organics can foul up membranes. NF
has low-fouling membranes and RO has high-fouling membranes. Since hard
water has great potential to foul membranes, RO usually requires water to be
softened first.
 RO system permeate has very low hardness and alkalinity, and therefore, it has
quite a high corrosion potential. This is why lower pH for RO permeate needs to
be adjusted to neutral pH.
 NF and RO membranes can be damaged by disinfectants like chlorine, unlike
those for microfiltration and ultrafiltration.
This is why chlorine and chloramines must be removed in the system prior to the NF
and RO membranes.
There are many benefits using nanofiltration technology as listed in sidebar: Table 1.
Due to the limitations of RO and softeners, we expect to see more POU/ POE
nanofiltration products in the marketplace in future.
Cang Li, Ph.D. (pictured, above) is director of research and development/quality control
at Selecto Scientific, Inc., based in Suwanee, GA, a producer, and provider of service
and installation for filtration technology for water and air treatment

More Related Content

Viewers also liked

Viewers also liked (15)

Membuat e
Membuat eMembuat e
Membuat e
 
30 aug traing slides
30 aug traing slides30 aug traing slides
30 aug traing slides
 
Redes sociales
Redes socialesRedes sociales
Redes sociales
 
Pilar g
Pilar gPilar g
Pilar g
 
Naturaleza
NaturalezaNaturaleza
Naturaleza
 
LOCAL Magazine with my article and ad
LOCAL Magazine with my article and adLOCAL Magazine with my article and ad
LOCAL Magazine with my article and ad
 
Prg c
Prg cPrg c
Prg c
 
Karito uso tec.
Karito  uso tec.Karito  uso tec.
Karito uso tec.
 
Presentation Lynx Unilever
Presentation Lynx UnileverPresentation Lynx Unilever
Presentation Lynx Unilever
 
9コマシナリオの使い方
9コマシナリオの使い方9コマシナリオの使い方
9コマシナリオの使い方
 
Advertisement
AdvertisementAdvertisement
Advertisement
 
[(주)에너지팜] 해외 태양광 발전 설비 구축 사례
[(주)에너지팜] 해외 태양광 발전 설비 구축 사례[(주)에너지팜] 해외 태양광 발전 설비 구축 사례
[(주)에너지팜] 해외 태양광 발전 설비 구축 사례
 
Presentacion3
Presentacion3Presentacion3
Presentacion3
 
1. el espíritu y la palabra
1. el espíritu y la palabra1. el espíritu y la palabra
1. el espíritu y la palabra
 
採用マーケティングの全体像
採用マーケティングの全体像採用マーケティングの全体像
採用マーケティングの全体像
 

Similar to Between uf and ro

Water recycling & membrane technology
Water recycling & membrane technologyWater recycling & membrane technology
Water recycling & membrane technologykanhaiya kumawat
 
Paper id 23201432
Paper id 23201432Paper id 23201432
Paper id 23201432IJRAT
 
Nano Filtration In Water Supply Systems
Nano Filtration In Water Supply SystemsNano Filtration In Water Supply Systems
Nano Filtration In Water Supply SystemsAqeel Ahamad
 
Membrane separation processe
Membrane separation processeMembrane separation processe
Membrane separation processeChan Pallem
 
Tertiary treatment
Tertiary treatmentTertiary treatment
Tertiary treatmentAzad Khan
 
A Brief Review Of Reverse Osmosis Membrane Technology
A Brief Review Of Reverse Osmosis Membrane TechnologyA Brief Review Of Reverse Osmosis Membrane Technology
A Brief Review Of Reverse Osmosis Membrane TechnologyTodd Turner
 
Sttp ppt msp_overview_09-10-2009_zvpm
Sttp ppt msp_overview_09-10-2009_zvpmSttp ppt msp_overview_09-10-2009_zvpm
Sttp ppt msp_overview_09-10-2009_zvpmArvind Kumar
 
Membrane filtration technology in food engg.
Membrane filtration technology in food engg.Membrane filtration technology in food engg.
Membrane filtration technology in food engg.Maya Sharma
 
Plant chemistry RO system
Plant chemistry RO system Plant chemistry RO system
Plant chemistry RO system umar farooq
 
Introduction to Membrane Technology and applications
Introduction to Membrane Technology and applicationsIntroduction to Membrane Technology and applications
Introduction to Membrane Technology and applicationssshoaib1
 
Ultra filtration and reverse osmosis
Ultra filtration and reverse osmosisUltra filtration and reverse osmosis
Ultra filtration and reverse osmosisRahul Kumar
 

Similar to Between uf and ro (20)

Nanofiltration
NanofiltrationNanofiltration
Nanofiltration
 
Treatment of water using reversed osmosis
Treatment of water using reversed osmosisTreatment of water using reversed osmosis
Treatment of water using reversed osmosis
 
Nanofiltration
Nanofiltration Nanofiltration
Nanofiltration
 
Ro ppt1 copy
Ro ppt1   copyRo ppt1   copy
Ro ppt1 copy
 
Water recycling & membrane technology
Water recycling & membrane technologyWater recycling & membrane technology
Water recycling & membrane technology
 
Membrane technology
Membrane technologyMembrane technology
Membrane technology
 
Presentation on water system
Presentation on water systemPresentation on water system
Presentation on water system
 
Paper id 23201432
Paper id 23201432Paper id 23201432
Paper id 23201432
 
Reverse Osmosis final.pptx
Reverse Osmosis final.pptxReverse Osmosis final.pptx
Reverse Osmosis final.pptx
 
Nano Filtration In Water Supply Systems
Nano Filtration In Water Supply SystemsNano Filtration In Water Supply Systems
Nano Filtration In Water Supply Systems
 
Membrane separation processe
Membrane separation processeMembrane separation processe
Membrane separation processe
 
Tertiary treatment
Tertiary treatmentTertiary treatment
Tertiary treatment
 
A Brief Review Of Reverse Osmosis Membrane Technology
A Brief Review Of Reverse Osmosis Membrane TechnologyA Brief Review Of Reverse Osmosis Membrane Technology
A Brief Review Of Reverse Osmosis Membrane Technology
 
ENS 37.pptx
ENS 37.pptxENS 37.pptx
ENS 37.pptx
 
Sttp ppt msp_overview_09-10-2009_zvpm
Sttp ppt msp_overview_09-10-2009_zvpmSttp ppt msp_overview_09-10-2009_zvpm
Sttp ppt msp_overview_09-10-2009_zvpm
 
Membrane filtration technology in food engg.
Membrane filtration technology in food engg.Membrane filtration technology in food engg.
Membrane filtration technology in food engg.
 
Plant chemistry RO system
Plant chemistry RO system Plant chemistry RO system
Plant chemistry RO system
 
Introduction to Membrane Technology and applications
Introduction to Membrane Technology and applicationsIntroduction to Membrane Technology and applications
Introduction to Membrane Technology and applications
 
Upload2 chemistry reverse osmisis
Upload2 chemistry reverse osmisisUpload2 chemistry reverse osmisis
Upload2 chemistry reverse osmisis
 
Ultra filtration and reverse osmosis
Ultra filtration and reverse osmosisUltra filtration and reverse osmosis
Ultra filtration and reverse osmosis
 

Between uf and ro

  • 1. Between UF and RO Nanofiltration is a pressure-driven membrane purification process whose characteristics fall between those of ultrafiltration (UF) and reverse osmosis (RO, also called hyperfiltration). See sidebar: Figure 1. Particle Size Scale. NF is also called low-pressure RO. Its membranes remove particles and small dissolved molecules and ions, usually hardness, iron, organics or color. Typical NF applications include water softening, desalination of dyestuffs, acid and caustic recovery, and color removal. The NF membrane An NF membrane works just like an RO membrane. The separation process for NF requires that the water be forced through a semi-permeable membrane in the opposite direction of natural osmotic flow, leaving contaminants in the more highly concentration solution (reject water). Nanofiltration membranes usually have three layers: a high-strength polyester base (approximately 150 microns thick), a microporous polysulfone interlayer (approximately 50 microns thick), and an ultra-thin polyamide barrier layer on the top surface (0.2 micron thick) See sidebar: Figure 2. NF Membrane Layers. NF membranes are mostly packed in a spiral-wound configuration. This configuration offers lower replacement costs and a simpler plumbing system, as well as easier maintenance and greater design freedom compared with tubular and flat plate designs. A cross-flow process is carried out by having a process solution or feedwater flow along a membrane surface under pressure. Cross-flow membrane filtration uses a high cross- flow rate to enhance permeate passage and to reduce membrane fouling. Retained solutes (such as dissolved salts) leave with the flowing process stream and do not accumulate on the membrane surface. Within the system Basic spiral-wound element construction makes use of flat sheet membrane cast onto a support fabric. The flat sheet membrane is enclosed between layers of feed spacer and permeate carrier. This process forms a leaf, which is sealed at each edge. Many leaves are rolled into a cylinder around a perforated central tube. Finished element diameters can be in a range of 2.5” to 18” with a length up to 60” (see sidebar: Figure 3. NF Membrane Elements). Standard test conditions for an NF element usually include feedwater, temperature, pressure, pH and recovery. The simplest NF system for POU/POE consists of a prefilter, an NF membrane filter, a booster pump, a storage tank for the treated water, and a flow regulator for the reject water, just like any RO system design.
  • 2. Nanofiltration is a low- to moderately high-pressure (typically 50 to 450 pounds per square inch [psi]) process in which monovalent ions will pass freely through the membrane but highly charged, multi-valent salts and low molecular weight organic molecules will be rejected to a much greater degree (see sidebar: Table 1. NF and RO Rejection Rates, Parameters). NF and RO: Similarities, differences Comparisons of NF with RO can be generally highlighted as followed:  Both are RO technology. The NF membrane is just a little “looser” — that is, RO will remove smaller-diameter particles than NF.  The key difference is the degree of removal of monovalent ions such as chlorides. RO removes monovalent ions at the 98 to 99 percent level at 200 psi. NF removal of monovalent ions varies between 10 and 90 percent, depending on the material and manufacture of the membrane.  In general, RO has less flow (produces less volume) than NF.  NF and RO are generally in the spiral-wound configuration.  RO membranes are characterized by high rejection of TDS (total dissolved solids) in the range of 98 to 99.5 percent.  NF membranes are characterized by higher water permeability than the RO membranes and lower TDS rejection.  NF membranes have sufficiently high rejection of selected constituents, i.e., hardness, metals (iron) and organic matter.  Membrane fouling: A high concentration of organics can foul up membranes. NF has low-fouling membranes and RO has high-fouling membranes. Since hard water has great potential to foul membranes, RO usually requires water to be softened first.  RO system permeate has very low hardness and alkalinity, and therefore, it has quite a high corrosion potential. This is why lower pH for RO permeate needs to be adjusted to neutral pH.  NF and RO membranes can be damaged by disinfectants like chlorine, unlike those for microfiltration and ultrafiltration. This is why chlorine and chloramines must be removed in the system prior to the NF and RO membranes. There are many benefits using nanofiltration technology as listed in sidebar: Table 1. Due to the limitations of RO and softeners, we expect to see more POU/ POE nanofiltration products in the marketplace in future. Cang Li, Ph.D. (pictured, above) is director of research and development/quality control at Selecto Scientific, Inc., based in Suwanee, GA, a producer, and provider of service and installation for filtration technology for water and air treatment