IVUS may not be clinically warranted in all interventions, and should be seen as an adjunct to angiography. IVUS provides information about vessel morphology, plaque topography, and therapeutic outcomes that is often either equivocal or unavailable in angiographic images.
There are 3 situations in which IVUS has the most clinical utility:
Small vessel stenting: Studies have shown that post-stent restenosis rates are higher in small vessels. This is particularly true for vessels with diameters of 3.0mm or less, wherein small increases in stent diameter have been shown to significantly decrease the rate of restenosis. A study by Moussa et al showed that, as measured by IVUS, the incidence of restenosis has an inverse relationship to the post-procedure in-stent lumen CSA1.
In-Stent restenosis: In these cases, IVUS helps to determine whether the restenosis is due to inadequate stent deployment (underexpansion or incomplete apposition) due to intimal hyperplasia. IVUS will also help you select the proper device size for treatment of the stented area.
Difficult to assess lesions: At times, images of a lesion and the adjacent reference segment are often hazy. IVUS should be used to identify whether the angiographic appearance is due to dissection, thrombus, residual plaque, or is benign.
IVUS may not be clinically warranted in all interventions, and should be seen as an adjunct to angiography. IVUS provides information about vessel morphology, plaque topography, and therapeutic outcomes that is often either equivocal or unavailable in angiographic images.
There are 3 situations in which IVUS has the most clinical utility:
Small vessel stenting: Studies have shown that post-stent restenosis rates are higher in small vessels. This is particularly true for vessels with diameters of 3.0mm or less, wherein small increases in stent diameter have been shown to significantly decrease the rate of restenosis. A study by Moussa et al showed that, as measured by IVUS, the incidence of restenosis has an inverse relationship to the post-procedure in-stent lumen CSA1.
In-Stent restenosis: In these cases, IVUS helps to determine whether the restenosis is due to inadequate stent deployment (underexpansion or incomplete apposition) due to intimal hyperplasia. IVUS will also help you select the proper device size for treatment of the stented area.
Difficult to assess lesions: At times, images of a lesion and the adjacent reference segment are often hazy. IVUS should be used to identify whether the angiographic appearance is due to dissection, thrombus, residual plaque, or is benign.
Basics of Interventional Radiology and Vascular Interventions RVRoshan Valentine
Brief overview of the general principles of interventional radiology, DSA, vascular interventions, catheters, guidewires, patient management, complications
Basics of Interventional Radiology and Vascular Interventions RVRoshan Valentine
Brief overview of the general principles of interventional radiology, DSA, vascular interventions, catheters, guidewires, patient management, complications
9. არითმიის შესაფასებელი 4
შეკითხვა
1 სიხშირე
2 რითმი რეგულარურია თუ
არარეგურალური
3 ყველა QRS კომპლექსს წინ უძღვის
თუ არა 1 P კბილი
4 კომპლექსი ვიწროა თუ ფართე 0,12 წმ
15. წინაგულოვანი ექსტრასისტოლა
სინუსური რითმის ფონზე, ერთი QRS
კომპლექსი ჩნდება უფრო მალე ვიდრე
იყო მოსალოდნელი
იმპულსი მოდის დამატებითი აგზნების
კერიდან
P კბილს აქვს განსხვავებული
მორფოლოგია
17. წინაგულთა ფიბრილაცია
მოციმციმე არითმია
წინაგულებში ქაოსურად
ერთდროულად წარმოიქმნება ბევრი
იმპულსი
წინაგულის კუნთის ცალკეული
უბნები ერთმანეთისგან
დამოუკიდებლად იკუმშება
18. წინაგულთა ფიბრილაცია
მოციმციმე არითმია
წინაგულებში იმპულსების
წარმოქმნის რაოდენობა არის წუთში
300-500 იმპულსი
ატრიოვენტრიკულური კვანძი ყველა
იმპულსს არ ატარებს პარკუჭებისკენ
19. წინაგულთა ფიბრილაცია
ეკგ კრიტერიუმები
წინაგულთა სიხშირის დათვლა
შეუძლებელია
პარკუჭების სიხშირე
განსხვავებულია სხვადასხვა
შემთხვევის დროს
პარკუჭების რითმი არის
არარეგულარულია
38. 38
AV Nodal
Tissue
AV Node
His-Purkinje System
P
QRS <0.12
>0.20 seconds
Sinus Node
• Underlying sinus rhythm
• One P wave
• PR interval >0.20
second
• One P wave for each
QRS
First-Degree AV