This document provides installation instructions for the Motorola AP 7181 Access Point. It describes hardware installation including mounting the access point, connecting power and antennas. Precautions for safe installation are outlined. Grounding requirements and guidelines for deploying the network are also covered, including recommended order for installing different node types. The document concludes with initial configuration steps and regulatory compliance information.
The document provides installation instructions for the Motorola RFS6000 Series RF Switch. It includes specifications for the switch, descriptions of the LED codes on the front panel, and step-by-step instructions for hardware setup including cabling, rack mounting, connecting power and verifying installation. The introduction describes the purpose of the switch in centralizing wireless LAN configuration and management.
Motorola solutions ap6522 m access point installation guide wing 5.5 versio...Advantec Distribution
This document provides installation instructions for the AP 6522M Access Point. It includes warnings for safe installation, descriptions of package contents which include the access point and installation guide, and features of the access point such as LED indicators and mounting options. Installation instructions are provided for wall mounting and mounting on suspended ceilings. Specifications and regulatory information are also included.
Motorola solutions ap6522 access point installation guide wi ng 5.5 version...Advantec Distribution
This document provides installation instructions for the AP6522 Access Point. It includes guidelines for site preparation, package contents, hardware installation including wall and ceiling mounting options, antenna configuration, LED indicators, basic access point configuration, specifications, regulatory information, and support contact details. Installation requires an Ethernet switch or power supply to power the access point via Ethernet cable.
The document is an installation guide for the AP6522 Access Point. It provides instructions on hardware installation including wall mounting and suspended ceiling mounting for integrated antenna and external antenna models. It also lists package contents, specifications, warnings and regulatory information. The guide is intended for qualified network installers to properly setup and configure the access point.
This document provides installation instructions for the AP-8232 Access Point. It describes what is included in the package, features of the access point, and guidelines for hardware installation including wall or ceiling mounting and connecting power. Detailed steps are provided for installation, safety precautions, positioning the access point, and using a power injector to provide power over Ethernet. Specifications and regulatory compliance information is also included.
Motorola air defense configuring an ap650 running wing 5.x as a sensor onlyAdvantec Distribution
The document provides instructions for configuring a Motorola AP650 access point as a sensor-only device. It describes the default configuration, how to log in and change passwords, configure basic settings like the country code and sensor server IPs, set the radios to sensor mode, optionally configure a static IP, and how to verify the configuration.
This document provides installation instructions for the AP-8222 Access Point. It includes guidelines for site preparation, package contents, hardware installation including wall or ceiling mounting, connecting the power injector system, and basic configuration of the access point. The document also provides specifications, regulatory information, and support contact details for the AP-8222.
Motorola solutions ap 6521 access point installation guide - wi ng 5.5 versio...Advantec Distribution
This document provides installation instructions for the Motorola Solutions AP-6521 Access Point. It describes the contents of the AP-6521 package, features of the access point, and guidelines for installation including wall mounting, suspended ceiling installation, and above-ceiling installation. Detailed steps are provided for hardware installation and basic access point configuration. Specifications including electrical, physical, and radio characteristics are also included.
The document provides installation instructions for the Motorola RFS6000 Series RF Switch. It includes specifications for the switch, descriptions of the LED codes on the front panel, and step-by-step instructions for hardware setup including cabling, rack mounting, connecting power and verifying installation. The introduction describes the purpose of the switch in centralizing wireless LAN configuration and management.
Motorola solutions ap6522 m access point installation guide wing 5.5 versio...Advantec Distribution
This document provides installation instructions for the AP 6522M Access Point. It includes warnings for safe installation, descriptions of package contents which include the access point and installation guide, and features of the access point such as LED indicators and mounting options. Installation instructions are provided for wall mounting and mounting on suspended ceilings. Specifications and regulatory information are also included.
Motorola solutions ap6522 access point installation guide wi ng 5.5 version...Advantec Distribution
This document provides installation instructions for the AP6522 Access Point. It includes guidelines for site preparation, package contents, hardware installation including wall and ceiling mounting options, antenna configuration, LED indicators, basic access point configuration, specifications, regulatory information, and support contact details. Installation requires an Ethernet switch or power supply to power the access point via Ethernet cable.
The document is an installation guide for the AP6522 Access Point. It provides instructions on hardware installation including wall mounting and suspended ceiling mounting for integrated antenna and external antenna models. It also lists package contents, specifications, warnings and regulatory information. The guide is intended for qualified network installers to properly setup and configure the access point.
This document provides installation instructions for the AP-8232 Access Point. It describes what is included in the package, features of the access point, and guidelines for hardware installation including wall or ceiling mounting and connecting power. Detailed steps are provided for installation, safety precautions, positioning the access point, and using a power injector to provide power over Ethernet. Specifications and regulatory compliance information is also included.
Motorola air defense configuring an ap650 running wing 5.x as a sensor onlyAdvantec Distribution
The document provides instructions for configuring a Motorola AP650 access point as a sensor-only device. It describes the default configuration, how to log in and change passwords, configure basic settings like the country code and sensor server IPs, set the radios to sensor mode, optionally configure a static IP, and how to verify the configuration.
This document provides installation instructions for the AP-8222 Access Point. It includes guidelines for site preparation, package contents, hardware installation including wall or ceiling mounting, connecting the power injector system, and basic configuration of the access point. The document also provides specifications, regulatory information, and support contact details for the AP-8222.
Motorola solutions ap 6521 access point installation guide - wi ng 5.5 versio...Advantec Distribution
This document provides installation instructions for the Motorola Solutions AP-6521 Access Point. It describes the contents of the AP-6521 package, features of the access point, and guidelines for installation including wall mounting, suspended ceiling installation, and above-ceiling installation. Detailed steps are provided for hardware installation and basic access point configuration. Specifications including electrical, physical, and radio characteristics are also included.
Motorola solutions ap6521 access point installation guide (part no. 72 e 1554...Advantec Distribution
The document provides installation instructions for the AP-6521 Series Access Point, which includes:
- Guidelines for mounting the access point on a wall, under a suspended ceiling, or above a ceiling.
- Details on the package contents, features, and specifications of the access point.
- Information on defining a basic configuration for the access point using an initial setup wizard.
Motorola solutions ap 6511 access point installation guide - wi ng 5.5 versio...Advantec Distribution
This document provides installation instructions for the Motorola Solutions AP-6511 Access Point. It can be mounted on a wall or in a telco box using the included mounting plate. The access point has one Ethernet port but can be expanded using an optional 3-port module. It requires Power over Ethernet and has LED indicators to show status. Detailed instructions are provided on physical installation, configuration, specifications, regulatory information, and support contacts.
This document provides installation instructions for the AP-7131 Series Access Point. It describes unpacking the access point and checking contents, guidelines for access point placement and antenna installation. It also outlines hardware installation including mounting options, connecting power, and port functions. Basic access point configuration steps are explained to complete installation. Specifications and additional resources are also referenced.
Motorola solutions ap6532 access point installation guide (part no. 72 e 1493...Advantec Distribution
This document provides installation instructions for the Motorola Solutions AP6532 Series Access Point. It includes details on package contents, hardware installation, initial setup, specifications, regulatory information, and support resources. The access point can be mounted on a wall or ceiling and receives power over Ethernet, with integrated antennas or external antenna options. Setup involves using an initial wizard to define a basic configuration.
Motorola solutions ap7131 access point installation guide wi ng 5.5 version...Advantec Distribution
This document provides installation instructions for the Motorola Solutions AP7131 and AP7131N Access Points. It describes unpacking the access point components, selecting an installation location considering antenna coverage, mounting options including wall, ceiling and above-ceiling mounting, connecting power and network cables, and configuring the access point LED indicators. The document also provides specifications for the access point models and regulatory compliance information.
Motorola solutions ap621 access point installation guide (part no. 72 e 15545...Advantec Distribution
This document provides installation instructions for the AP-621 Series Access Point. It describes how to wall mount, ceiling mount, or mount above the ceiling the access point. It also discusses antenna options, using a power injector for PoE, and LED indicators. Proper placement of the access point is emphasized to maximize coverage while avoiding interference.
The document is a user manual for the HDL-32E High Definition LiDAR Sensor that provides the following information:
1) It describes how to set up the sensor by unpacking contents, securely mounting the base, connecting power and connecting the sensor's data output to a computer.
2) It explains the principles of operation, noting that the sensor uses 32 laser/detector pairs in a housing that rapidly spins to scan the surrounding environment and provide a rich 3D point cloud.
3) It provides instructions for connecting power, mounting the base, and connecting to a computer via an Ethernet cable, and notes the sensor requires no additional configuration or calibration to begin producing usable data packets.
This document provides installation and operation instructions for the SSM23Q/IP integrated step-servo motor. It includes:
1. An overview of the motor's features such as torque capabilities, control modes, inputs/outputs, and Ethernet communication.
2. Instructions for installing the necessary software, mounting the motor, and choosing an appropriate power supply.
3. Details on connecting the power supply, connecting the motor to a PC over Ethernet, and descriptions of the input and output connections.
4. Contact information for support.
This document is a quick start guide for a Dahua HD IR vandal proof network dome camera. It includes sections on device structure and components, installation instructions, and network configuration steps. Safety warnings are provided at the beginning regarding electrical safety, environment, operation, and maintenance of the camera.
Motorola ap 7131 series access point product reference guide (part no. 72 e-1...Advantec Distribution
The document is a product reference guide for the AP-7131 Series Access Point. It describes new features of the access point including power management antenna configuration, hotspot customization, WAN failover, proxy ARP support, and multi-cipher support. It provides an overview of the access point's features such as 802.11n support, sensor support, mesh networking, security, management, and quality of service capabilities. The document also outlines the access point's theory of operations.
This document is a user guide for the SQ Blaster Plus and SQ Remote applications. It provides instructions over multiple parts on setting up the SQ Blaster device, connecting it to a home Wi-Fi network, adding infrared command codes for devices, setting up control pads in SQ Remote, adding and editing controls, creating macros, and other functions. The guide includes screenshots and step-by-step explanations to walk users through the full setup and customization process.
This document provides installation instructions for the Motorola RFS7000 Series RF Switch. It describes the physical specifications, power requirements, port connections including Ethernet, USB, and console ports, as well as instructions for rack mounting and powering on the device. LED codes and patterns are explained to verify proper installation and operation.
The document provides specifications for the MSI K8N Neo3 (MS-7135) v1.X ATX mainboard, including support for AMD K8 Athlon 64 processors, nVIDIA nForce4-4X chipset, DDR memory, PCI Express and AGP slots, SATA and IDE interfaces, audio and LAN connectivity, and BIOS features. A diagram shows the mainboard layout and location of connectors, slots, buttons and other components. Safety instructions and packaging contents are also outlined.
The document provides troubleshooting guidance for common issues with wireless switches, including: switch boot up problems, IP address assignment via DHCP, connectivity issues using Telnet/SSH, slow or unresponsive web interface, faulty console port, VLAN configuration loss after reboot, access port adoption failures, mobile unit association problems, failover malfunctions, version number changes after upgrades, excessive network traffic, and memory leaks. It also describes the system status LEDs and logging mechanism to help diagnose issues.
This document contains the user manual for a solar power regulator system. It includes sections describing the general information, system summary, hardware components, circuit schematic, potential issues, program flowchart, and full program code. The solar power regulator uses a PIC microcontroller to monitor voltage from solar panels and temperature of a power containment unit (PCU). It can display readings on an LCD, trigger a fan if temperature exceeds limits, and disconnect power if voltage or temperature thresholds are exceeded. The full program code for running the regulator is provided.
1. Obtain a new license key from Cambium using the unique Access Key.
2. Connect to the PTP 600 unit and navigate to the License Key page.
3. Enter the new license key to enable the optical interface capability.
4. Connect the fiber optic cable to the SFP module and configure the SFP settings.
5. The unit can now be connected to the fiber network and configured for operation.
This document provides information on professional radio accessories from SAVOX, including push-to-talk units, headset adapters, helmet attachments, and more. The accessories are designed for demanding professional use in public safety. SAVOX accessories are compatible with radios from many manufacturers and prioritize usability, ruggedness, and reliability. They include options for different environments like firefighting and industrial use.
This document summarizes Motorola's ATEX-approved Professional Series portable radios for use in hazardous environments. It introduces the GP340 EX, GP380 EX, GP580 EX, and GP680 EX radios, which feature safety approvals allowing operation in potentially explosive atmospheres. The radios are designed to provide reliable communications while meeting European ATEX directives for equipment used in explosive gas and dust environments. Key features and specifications of each radio model are then described in detail.
The document describes the AP-7131-GR, an 802.11n wireless access point that is the first to achieve FIPS 140-2 Level 2 validation. It has dual-band radios that allow it to simultaneously support wireless data, voice, video and wireless intrusion prevention system functionality. It provides high security for government agencies through its certifications and ability to continuously monitor the wireless spectrum for rogue devices on both 2.4GHz and 5GHz bands while still supporting wireless traffic. This consolidated device replaces the need for separate access points and wireless sensors to reduce costs.
The document describes the NX 9500 Integrated Services Platform for centralized network management. Key features include:
1. Centralized management and control of distributed networks including access points, devices, and branch office platforms from a single interface.
2. Comprehensive visibility, configuration, troubleshooting, and assurance of networks with up to 10,000 elements across multiple locations.
3. Management of wireless networks, security policies, devices, applications, and services from a single pane of glass.
This document is the CLI Reference Guide for Motorola Solutions' WiNG 4.4 software. It provides instructions and references for using the command line interface (CLI) to configure WiNG devices. The guide describes CLI modes, context sensitive help, editing features, and common commands such as show, configure, and clear. It also provides tables of commands for key functions like interfaces, routing, switching, and more.
Motorola solutions ap6521 access point installation guide (part no. 72 e 1554...Advantec Distribution
The document provides installation instructions for the AP-6521 Series Access Point, which includes:
- Guidelines for mounting the access point on a wall, under a suspended ceiling, or above a ceiling.
- Details on the package contents, features, and specifications of the access point.
- Information on defining a basic configuration for the access point using an initial setup wizard.
Motorola solutions ap 6511 access point installation guide - wi ng 5.5 versio...Advantec Distribution
This document provides installation instructions for the Motorola Solutions AP-6511 Access Point. It can be mounted on a wall or in a telco box using the included mounting plate. The access point has one Ethernet port but can be expanded using an optional 3-port module. It requires Power over Ethernet and has LED indicators to show status. Detailed instructions are provided on physical installation, configuration, specifications, regulatory information, and support contacts.
This document provides installation instructions for the AP-7131 Series Access Point. It describes unpacking the access point and checking contents, guidelines for access point placement and antenna installation. It also outlines hardware installation including mounting options, connecting power, and port functions. Basic access point configuration steps are explained to complete installation. Specifications and additional resources are also referenced.
Motorola solutions ap6532 access point installation guide (part no. 72 e 1493...Advantec Distribution
This document provides installation instructions for the Motorola Solutions AP6532 Series Access Point. It includes details on package contents, hardware installation, initial setup, specifications, regulatory information, and support resources. The access point can be mounted on a wall or ceiling and receives power over Ethernet, with integrated antennas or external antenna options. Setup involves using an initial wizard to define a basic configuration.
Motorola solutions ap7131 access point installation guide wi ng 5.5 version...Advantec Distribution
This document provides installation instructions for the Motorola Solutions AP7131 and AP7131N Access Points. It describes unpacking the access point components, selecting an installation location considering antenna coverage, mounting options including wall, ceiling and above-ceiling mounting, connecting power and network cables, and configuring the access point LED indicators. The document also provides specifications for the access point models and regulatory compliance information.
Motorola solutions ap621 access point installation guide (part no. 72 e 15545...Advantec Distribution
This document provides installation instructions for the AP-621 Series Access Point. It describes how to wall mount, ceiling mount, or mount above the ceiling the access point. It also discusses antenna options, using a power injector for PoE, and LED indicators. Proper placement of the access point is emphasized to maximize coverage while avoiding interference.
The document is a user manual for the HDL-32E High Definition LiDAR Sensor that provides the following information:
1) It describes how to set up the sensor by unpacking contents, securely mounting the base, connecting power and connecting the sensor's data output to a computer.
2) It explains the principles of operation, noting that the sensor uses 32 laser/detector pairs in a housing that rapidly spins to scan the surrounding environment and provide a rich 3D point cloud.
3) It provides instructions for connecting power, mounting the base, and connecting to a computer via an Ethernet cable, and notes the sensor requires no additional configuration or calibration to begin producing usable data packets.
This document provides installation and operation instructions for the SSM23Q/IP integrated step-servo motor. It includes:
1. An overview of the motor's features such as torque capabilities, control modes, inputs/outputs, and Ethernet communication.
2. Instructions for installing the necessary software, mounting the motor, and choosing an appropriate power supply.
3. Details on connecting the power supply, connecting the motor to a PC over Ethernet, and descriptions of the input and output connections.
4. Contact information for support.
This document is a quick start guide for a Dahua HD IR vandal proof network dome camera. It includes sections on device structure and components, installation instructions, and network configuration steps. Safety warnings are provided at the beginning regarding electrical safety, environment, operation, and maintenance of the camera.
Motorola ap 7131 series access point product reference guide (part no. 72 e-1...Advantec Distribution
The document is a product reference guide for the AP-7131 Series Access Point. It describes new features of the access point including power management antenna configuration, hotspot customization, WAN failover, proxy ARP support, and multi-cipher support. It provides an overview of the access point's features such as 802.11n support, sensor support, mesh networking, security, management, and quality of service capabilities. The document also outlines the access point's theory of operations.
This document is a user guide for the SQ Blaster Plus and SQ Remote applications. It provides instructions over multiple parts on setting up the SQ Blaster device, connecting it to a home Wi-Fi network, adding infrared command codes for devices, setting up control pads in SQ Remote, adding and editing controls, creating macros, and other functions. The guide includes screenshots and step-by-step explanations to walk users through the full setup and customization process.
This document provides installation instructions for the Motorola RFS7000 Series RF Switch. It describes the physical specifications, power requirements, port connections including Ethernet, USB, and console ports, as well as instructions for rack mounting and powering on the device. LED codes and patterns are explained to verify proper installation and operation.
The document provides specifications for the MSI K8N Neo3 (MS-7135) v1.X ATX mainboard, including support for AMD K8 Athlon 64 processors, nVIDIA nForce4-4X chipset, DDR memory, PCI Express and AGP slots, SATA and IDE interfaces, audio and LAN connectivity, and BIOS features. A diagram shows the mainboard layout and location of connectors, slots, buttons and other components. Safety instructions and packaging contents are also outlined.
The document provides troubleshooting guidance for common issues with wireless switches, including: switch boot up problems, IP address assignment via DHCP, connectivity issues using Telnet/SSH, slow or unresponsive web interface, faulty console port, VLAN configuration loss after reboot, access port adoption failures, mobile unit association problems, failover malfunctions, version number changes after upgrades, excessive network traffic, and memory leaks. It also describes the system status LEDs and logging mechanism to help diagnose issues.
This document contains the user manual for a solar power regulator system. It includes sections describing the general information, system summary, hardware components, circuit schematic, potential issues, program flowchart, and full program code. The solar power regulator uses a PIC microcontroller to monitor voltage from solar panels and temperature of a power containment unit (PCU). It can display readings on an LCD, trigger a fan if temperature exceeds limits, and disconnect power if voltage or temperature thresholds are exceeded. The full program code for running the regulator is provided.
1. Obtain a new license key from Cambium using the unique Access Key.
2. Connect to the PTP 600 unit and navigate to the License Key page.
3. Enter the new license key to enable the optical interface capability.
4. Connect the fiber optic cable to the SFP module and configure the SFP settings.
5. The unit can now be connected to the fiber network and configured for operation.
This document provides information on professional radio accessories from SAVOX, including push-to-talk units, headset adapters, helmet attachments, and more. The accessories are designed for demanding professional use in public safety. SAVOX accessories are compatible with radios from many manufacturers and prioritize usability, ruggedness, and reliability. They include options for different environments like firefighting and industrial use.
This document summarizes Motorola's ATEX-approved Professional Series portable radios for use in hazardous environments. It introduces the GP340 EX, GP380 EX, GP580 EX, and GP680 EX radios, which feature safety approvals allowing operation in potentially explosive atmospheres. The radios are designed to provide reliable communications while meeting European ATEX directives for equipment used in explosive gas and dust environments. Key features and specifications of each radio model are then described in detail.
The document describes the AP-7131-GR, an 802.11n wireless access point that is the first to achieve FIPS 140-2 Level 2 validation. It has dual-band radios that allow it to simultaneously support wireless data, voice, video and wireless intrusion prevention system functionality. It provides high security for government agencies through its certifications and ability to continuously monitor the wireless spectrum for rogue devices on both 2.4GHz and 5GHz bands while still supporting wireless traffic. This consolidated device replaces the need for separate access points and wireless sensors to reduce costs.
The document describes the NX 9500 Integrated Services Platform for centralized network management. Key features include:
1. Centralized management and control of distributed networks including access points, devices, and branch office platforms from a single interface.
2. Comprehensive visibility, configuration, troubleshooting, and assurance of networks with up to 10,000 elements across multiple locations.
3. Management of wireless networks, security policies, devices, applications, and services from a single pane of glass.
This document is the CLI Reference Guide for Motorola Solutions' WiNG 4.4 software. It provides instructions and references for using the command line interface (CLI) to configure WiNG devices. The guide describes CLI modes, context sensitive help, editing features, and common commands such as show, configure, and clear. It also provides tables of commands for key functions like interfaces, routing, switching, and more.
Motorola solutions ap7181 access point installation guide wi ng 5.5 version...Advantec Distribution
This document provides installation instructions for the Motorola Solutions AP 7181 access point. It discusses hardware installation including precautions, deployment guidelines, grounding requirements, and placement of the access point. It also covers connecting and configuring the access point, as well as regulatory information. The document is an in-depth guide for installing the AP 7181 access point hardware and ensuring proper configuration and regulatory compliance.
This document provides installation instructions for the AP-7131 Series Access Point. It describes unpacking the access point and checking contents, guidelines for access point placement and antenna installation. It also outlines hardware installation including mounting options, connecting power, and port functions. Basic access point configuration steps are explained to complete installation. Specifications and additional resources are also referenced.
Motorola solutions ap621 access point installation guide (part no. 72 e 15545...Advantec Distribution
This document provides installation instructions for the AP-621 Series access point. It describes the package contents, features of the access point, and guidelines for hardware installation including wall mounting, suspended ceiling mounting, and above-ceiling mounting. Precautions and considerations for optimal access point placement are also covered. Specifications for electrical, physical, and radio characteristics are listed.
Motorola solutions ap621 access point installation guide (part no. 72 e 15545...Advantec Distribution
This document provides installation instructions for the Motorola Solutions AP-621 Series Access Point. It describes the package contents, features of the access point, and guidelines for hardware installation including wall mounting, mounting under a suspended ceiling, and above-ceiling installation. Detailed instructions are provided for each installation method. Power options including a Power Injector that combines data and power over a single Ethernet cable are also discussed.
Motorola solutions ap621 access point installation guide (part no. 72 e 15545...Advantec Distribution
This document provides installation instructions for the Motorola AP-621 Series Access Point. It includes information on site preparation, package contents, features of the access point, and hardware installation instructions for wall mounting, suspended ceiling mounting, and above-ceiling mounting. Detailed specifications for electrical, physical, and radio characteristics are also provided, as well as regulatory information and support contact details.
Motorola solutions ap621 access point installation guide (part no. 72 e 15545...Advantec Distribution
This document provides installation instructions for the AP-621 Series Access Point. It describes how to wall mount, ceiling mount, or mount above the ceiling the access point. It also discusses antenna options, using a power injector for PoE, and LED indicators. Proper placement of the access point is emphasized to maximize coverage while avoiding interference.
Motorola solutions ap621 access point installation guide (part no. 72 e 15545...Advantec Distribution
This document provides installation instructions for the AP-621 Series Access Point. It describes how to wall mount, ceiling mount, or mount above the ceiling the access point. It also details the package contents, features of the access point like LED indicators, and specifications. Basic configuration and regulatory information is also included.
Motorola solutions enterprise noc wireless lan controller install guide (part...Advantec Distribution
This document provides instructions for installing the NX 9000 Wireless LAN Controller appliance, including physically installing it in a rack, connecting it to power and the network, and initially accessing the management interface. The three step installation process includes installing the appliance, powering it up, and then accessing the management interface through a connected keyboard and monitor. Safety precautions and requirements for rack installation are also outlined.
Motorola solutions ap7161 access point installation guide wi ng 5.5 version...Advantec Distribution
This document provides installation and configuration instructions for the Motorola Solutions AP 7161 Access Point. It describes the AP 7161 hardware components, including antennas, ports, LED indicators, and mounting accessories. It also provides guidelines for installing the access point on poles or walls outdoors, as well as configuring the basic settings and connecting power over Ethernet. The document includes specifications, regulatory information, and troubleshooting steps.
This document provides information about the MS-7260 mainboard, including specifications, layout, included components, installation instructions for parts like the CPU and memory, and descriptions of connectors. It includes safety instructions and regulatory compliance statements. Revisions to the document are tracked, and contact information is provided for technical support.
Motorola solutions ap622 access point installation guide (part no. 72 e 15780...Advantec Distribution
This document provides installation instructions for the Motorola Solutions AP-0622 access point. It describes how to wall mount or ceiling mount both the integrated antenna and external antenna models. The external antenna model package contents and mounting options are also outlined. The document provides specifications for the access point and regulatory information.
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )Advantec Distribution
The document is an installation guide for the MAP-650 Series Thin Access Point. It contains instructions for installing both models of the access point - one with integrated antennas and one with external antennas. The guide discusses preparing the installation site, includes warnings for safe installation, and provides step-by-step instructions for mounting the access points to walls or ceilings. It also contains specifications, regulatory information, and details on customer support resources.
The camera supports two-way audio function. An external speaker and microphone need to connect to the
camera for audio input and output.
The users may click the “Talk” button on the Live View page to talk to the site, and click “Listen” to listen to
the audio input from site.
The audio function is very useful for communication and monitoring purposes.
Advanced
19
Camera Advanced Setting:
Exposure Mode:
Auto: The camera automatically adjusts the exposure level according to the environment illumination.
Manual: The user can manually adjust the exposure level by setting the shutter speed and gain level.
Shutter Speed:
The shutter speed refers to the electronic shutter speed which controls
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )Advantec Distribution
The document provides instructions for installing the Motorola AP-650 Thin Access Point, which can be mounted on a wall or suspended ceiling. It includes details on package contents, placement guidelines, wall and ceiling mounting procedures, and specifications. The integrated antenna model mounts using wall screws or clips on a suspended ceiling T-bar. The external antenna model also mounts on walls or ceilings and has options for external antenna connections.
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )Advantec Distribution
The document provides installation instructions for the Motorola AP-650 Series Thin Access Point. It includes details on package contents, features, hardware installation instructions for wall and ceiling mounts, specifications, regulatory information, and customer support resources. Wall and ceiling mount options are described along with required hardware. Status indicators and technical specifications are listed.
The document provides installation instructions for the Motorola AP-650 Thin Access Point. It can be mounted on a wall or suspended ceiling and is available with integrated or external antennas. The document describes the package contents, features, wall and ceiling mounting procedures, specifications, regulatory information, and support resources. Installation requires attaching the access point to a wall or ceiling using the provided hardware and connecting an Ethernet cable from the access point to a switch with 802.3af power.
The document provides installation instructions for the Motorola AP-650 Thin Access Point. It can be mounted on a wall or suspended ceiling and comes in integrated antenna and external antenna models. The instructions describe the package contents, recommended placement, and step-by-step procedures for wall mounting or mounting on a suspended ceiling T-bar for both antenna models. Specifications and regulatory information are also included.
Motorola solutions rfs4011 integrated service controller installation guide ...Advantec Distribution
This document provides installation instructions for the Motorola RFS4011 Integrated Service Controller. It includes specifications for the device, descriptions of the LED codes, instructions for hardware setup and basic configuration, as well as regulatory information. The hardware setup section provides guidance on cabling, installing Gigabit Ethernet and USB devices, rack mounting, connecting antennas, the console port, power supply, resetting passwords, and verifying installation. The configuration section describes initial device configuration.
This document is the user manual for the KE8220 Virtual VNC Console. It contains information about FCC regulations and RoHS compliance for the device. The manual provides details on the package contents, hardware setup instructions, and component descriptions to help users install and operate the KE8220 console.
This document provides an overview of the hardware components used in programmable logic controllers (PLCs). It describes the basic PLC components such as the CPU module, power supply module, and input/output modules. It also covers number addressing schemes for inputs and outputs. Specialized modules are discussed, including analog, temperature control, counter, positioning, and communication modules. An overview of programming software is also provided.
Cambium Networks is an industry leader in point-to-multipoint and point-to-point wireless broadband solutions. They have shipped over 4 million nodes totaling over $1 billion to networks in more than 150 countries. Their ePMP product line provides affordable and scalable wireless access networks through features like GPS synchronization, high scalability and consistent performance, interference mitigation technology, and effective quality of service capabilities.
The VX 9000 virtualized software-based wireless LAN controller combines the power of virtualization with Motorola Solutions' WiNG Controller. It provides centralized management of wireless networks through a single interface with high scalability, flexibility and advanced wireless services. Key features include integrated network security, the advanced WiNG 5 operating system, plug-and-play deployment, simplified licensing and infinite scalability through virtualization. It supports all major hypervisors and public/private clouds for maximum deployment flexibility at low cost.
The NX 7500 integrated services platform provides comprehensive management of up to 2,048 network elements through a single interface. It allows all network infrastructure to intelligently route traffic for maximum speed and throughput without congestion. The NX 7500 offers advanced wireless LAN performance for mid-sized and campus environments with features such as plug-and-play installation, hierarchical management, smart routing, BYOD support, and integrated security services. It provides flexibility and investment protection through modular upgrades.
The document discusses the challenges retailers face in supporting increased wireless applications and next-generation Wi-Fi in stores. It introduces the Motorola AP 8200 Series as a solution that provides high-performance wireless connectivity for customers and staff. The AP 8200 Series allows easy access, security, support for 802.11ac Wi-Fi, bandwidth for applications, and performance for many users. It provides flexibility, a cost-effective upgrade to 802.11ac, and features for security, environmental monitoring, location services, and more.
The document describes the innovative features of the Motorola AP 8222 wireless access point. It has a sleek design suitable for retail, office, and other customer-facing spaces. It provides dual-band 802.11ac and 802.11n wireless connectivity at speeds up to 1.3Gbps. Key features include advanced beamforming, gap-free security, and support for bandwidth-heavy applications like video calling. The access point is centrally managed through Motorola's WiNG 5 networking operating system.
The AP 8163 is a ruggedized outdoor mesh access point designed to withstand extreme weather conditions. It has three radios - two for client access across 2.4GHz and 5GHz bands, and a third radio that can be used for wireless intrusion prevention scanning or dynamic frequency selection to avoid radar interference. The advanced WiNG 5 operating system allows the access points to self-optimize the network for best performance. Key features include powerful antennas for extended range, mesh networking for redundancy, and security features like firewalls and wireless intrusion prevention.
The document describes the features and capabilities of the Motorola AP 8122 3x3 MIMO 802.11n access point. It delivers high throughput to support enterprise applications including voice and HD video using 802.11n technology with standard 802.3af PoE. It has advanced features like load balancing, pre-emptive roaming, and dual band radios to increase network reliability, resilience, and security. The access point also supports advanced wireless capabilities such as voice over wireless, location services, and guest access controls.
The document describes the innovative features of the AP 7532 wireless access point. It provides the highest wireless speeds available with 3x3 MIMO and 256 QAM modulation on both 2.4GHz and 5GHz radios. It has a dual radio 802.11ac/802.11n design that provides a upgrade path to 1.3Gbps 802.11ac speeds while maintaining support for existing devices. It offers various advanced features like load balancing, security, sensor support and quality of service for voice. The access point is designed to deliver maximum performance at a low cost.
The AP 7502 is a dual-band 802.11ac wireless access point designed for installation in small spaces like hotel rooms. It has a compact wall-mount design, supports the latest WiFi standards, and includes features to ensure reliable connectivity even in challenging environments. Setup and management are simplified through zero-touch provisioning and both standalone and controller-based operation modes.
The document describes the innovative features of the AP 7522 wireless access point. It provides dual-band 802.11ac and 802.11n radios for high performance WiFi. It offers internal or external antenna options and can function as both an access point and wireless sensor. The access point provides security, load balancing, and other features to support mission critical applications on the wireless network.
For the full video of this presentation, please visit: https://www.edge-ai-vision.com/2024/06/temporal-event-neural-networks-a-more-efficient-alternative-to-the-transformer-a-presentation-from-brainchip/
Chris Jones, Director of Product Management at BrainChip , presents the “Temporal Event Neural Networks: A More Efficient Alternative to the Transformer” tutorial at the May 2024 Embedded Vision Summit.
The expansion of AI services necessitates enhanced computational capabilities on edge devices. Temporal Event Neural Networks (TENNs), developed by BrainChip, represent a novel and highly efficient state-space network. TENNs demonstrate exceptional proficiency in handling multi-dimensional streaming data, facilitating advancements in object detection, action recognition, speech enhancement and language model/sequence generation. Through the utilization of polynomial-based continuous convolutions, TENNs streamline models, expedite training processes and significantly diminish memory requirements, achieving notable reductions of up to 50x in parameters and 5,000x in energy consumption compared to prevailing methodologies like transformers.
Integration with BrainChip’s Akida neuromorphic hardware IP further enhances TENNs’ capabilities, enabling the realization of highly capable, portable and passively cooled edge devices. This presentation delves into the technical innovations underlying TENNs, presents real-world benchmarks, and elucidates how this cutting-edge approach is positioned to revolutionize edge AI across diverse applications.
Fueling AI with Great Data with Airbyte WebinarZilliz
This talk will focus on how to collect data from a variety of sources, leveraging this data for RAG and other GenAI use cases, and finally charting your course to productionalization.
HCL Notes and Domino License Cost Reduction in the World of DLAUpanagenda
Webinar Recording: https://www.panagenda.com/webinars/hcl-notes-and-domino-license-cost-reduction-in-the-world-of-dlau/
The introduction of DLAU and the CCB & CCX licensing model caused quite a stir in the HCL community. As a Notes and Domino customer, you may have faced challenges with unexpected user counts and license costs. You probably have questions on how this new licensing approach works and how to benefit from it. Most importantly, you likely have budget constraints and want to save money where possible. Don’t worry, we can help with all of this!
We’ll show you how to fix common misconfigurations that cause higher-than-expected user counts, and how to identify accounts which you can deactivate to save money. There are also frequent patterns that can cause unnecessary cost, like using a person document instead of a mail-in for shared mailboxes. We’ll provide examples and solutions for those as well. And naturally we’ll explain the new licensing model.
Join HCL Ambassador Marc Thomas in this webinar with a special guest appearance from Franz Walder. It will give you the tools and know-how to stay on top of what is going on with Domino licensing. You will be able lower your cost through an optimized configuration and keep it low going forward.
These topics will be covered
- Reducing license cost by finding and fixing misconfigurations and superfluous accounts
- How do CCB and CCX licenses really work?
- Understanding the DLAU tool and how to best utilize it
- Tips for common problem areas, like team mailboxes, functional/test users, etc
- Practical examples and best practices to implement right away
Connector Corner: Seamlessly power UiPath Apps, GenAI with prebuilt connectorsDianaGray10
Join us to learn how UiPath Apps can directly and easily interact with prebuilt connectors via Integration Service--including Salesforce, ServiceNow, Open GenAI, and more.
The best part is you can achieve this without building a custom workflow! Say goodbye to the hassle of using separate automations to call APIs. By seamlessly integrating within App Studio, you can now easily streamline your workflow, while gaining direct access to our Connector Catalog of popular applications.
We’ll discuss and demo the benefits of UiPath Apps and connectors including:
Creating a compelling user experience for any software, without the limitations of APIs.
Accelerating the app creation process, saving time and effort
Enjoying high-performance CRUD (create, read, update, delete) operations, for
seamless data management.
Speakers:
Russell Alfeche, Technology Leader, RPA at qBotic and UiPath MVP
Charlie Greenberg, host
Freshworks Rethinks NoSQL for Rapid Scaling & Cost-EfficiencyScyllaDB
Freshworks creates AI-boosted business software that helps employees work more efficiently and effectively. Managing data across multiple RDBMS and NoSQL databases was already a challenge at their current scale. To prepare for 10X growth, they knew it was time to rethink their database strategy. Learn how they architected a solution that would simplify scaling while keeping costs under control.
Northern Engraving | Nameplate Manufacturing Process - 2024Northern Engraving
Manufacturing custom quality metal nameplates and badges involves several standard operations. Processes include sheet prep, lithography, screening, coating, punch press and inspection. All decoration is completed in the flat sheet with adhesive and tooling operations following. The possibilities for creating unique durable nameplates are endless. How will you create your brand identity? We can help!
How to Interpret Trends in the Kalyan Rajdhani Mix Chart.pdfChart Kalyan
A Mix Chart displays historical data of numbers in a graphical or tabular form. The Kalyan Rajdhani Mix Chart specifically shows the results of a sequence of numbers over different periods.
Programming Foundation Models with DSPy - Meetup SlidesZilliz
Prompting language models is hard, while programming language models is easy. In this talk, I will discuss the state-of-the-art framework DSPy for programming foundation models with its powerful optimizers and runtime constraint system.
Skybuffer SAM4U tool for SAP license adoptionTatiana Kojar
Manage and optimize your license adoption and consumption with SAM4U, an SAP free customer software asset management tool.
SAM4U, an SAP complimentary software asset management tool for customers, delivers a detailed and well-structured overview of license inventory and usage with a user-friendly interface. We offer a hosted, cost-effective, and performance-optimized SAM4U setup in the Skybuffer Cloud environment. You retain ownership of the system and data, while we manage the ABAP 7.58 infrastructure, ensuring fixed Total Cost of Ownership (TCO) and exceptional services through the SAP Fiori interface.
Driving Business Innovation: Latest Generative AI Advancements & Success StorySafe Software
Are you ready to revolutionize how you handle data? Join us for a webinar where we’ll bring you up to speed with the latest advancements in Generative AI technology and discover how leveraging FME with tools from giants like Google Gemini, Amazon, and Microsoft OpenAI can supercharge your workflow efficiency.
During the hour, we’ll take you through:
Guest Speaker Segment with Hannah Barrington: Dive into the world of dynamic real estate marketing with Hannah, the Marketing Manager at Workspace Group. Hear firsthand how their team generates engaging descriptions for thousands of office units by integrating diverse data sources—from PDF floorplans to web pages—using FME transformers, like OpenAIVisionConnector and AnthropicVisionConnector. This use case will show you how GenAI can streamline content creation for marketing across the board.
Ollama Use Case: Learn how Scenario Specialist Dmitri Bagh has utilized Ollama within FME to input data, create custom models, and enhance security protocols. This segment will include demos to illustrate the full capabilities of FME in AI-driven processes.
Custom AI Models: Discover how to leverage FME to build personalized AI models using your data. Whether it’s populating a model with local data for added security or integrating public AI tools, find out how FME facilitates a versatile and secure approach to AI.
We’ll wrap up with a live Q&A session where you can engage with our experts on your specific use cases, and learn more about optimizing your data workflows with AI.
This webinar is ideal for professionals seeking to harness the power of AI within their data management systems while ensuring high levels of customization and security. Whether you're a novice or an expert, gain actionable insights and strategies to elevate your data processes. Join us to see how FME and AI can revolutionize how you work with data!
Ivanti’s Patch Tuesday breakdown goes beyond patching your applications and brings you the intelligence and guidance needed to prioritize where to focus your attention first. Catch early analysis on our Ivanti blog, then join industry expert Chris Goettl for the Patch Tuesday Webinar Event. There we’ll do a deep dive into each of the bulletins and give guidance on the risks associated with the newly-identified vulnerabilities.
Have you ever been confused by the myriad of choices offered by AWS for hosting a website or an API?
Lambda, Elastic Beanstalk, Lightsail, Amplify, S3 (and more!) can each host websites + APIs. But which one should we choose?
Which one is cheapest? Which one is fastest? Which one will scale to meet our needs?
Join me in this session as we dive into each AWS hosting service to determine which one is best for your scenario and explain why!
AppSec PNW: Android and iOS Application Security with MobSFAjin Abraham
Mobile Security Framework - MobSF is a free and open source automated mobile application security testing environment designed to help security engineers, researchers, developers, and penetration testers to identify security vulnerabilities, malicious behaviours and privacy concerns in mobile applications using static and dynamic analysis. It supports all the popular mobile application binaries and source code formats built for Android and iOS devices. In addition to automated security assessment, it also offers an interactive testing environment to build and execute scenario based test/fuzz cases against the application.
This talk covers:
Using MobSF for static analysis of mobile applications.
Interactive dynamic security assessment of Android and iOS applications.
Solving Mobile app CTF challenges.
Reverse engineering and runtime analysis of Mobile malware.
How to shift left and integrate MobSF/mobsfscan SAST and DAST in your build pipeline.
7. Introduction 1
1 Introduction
The purpose of this document is to provide installation and setup procedures for Motorola’s
AP 7181 Access Point.
The AP 7181 is a wireless broadband data system that uses mesh networking technology to
support wide-area broadband data coverage. The system offers both 2.4 GHz 802.11b/g/n
and 5.x GHz 802.11n Wi-Fi client access with 2.4 GHz 802.11 b/g/n and 5.x GHz 802.11a/
n meshing. The dual-band system supports industry standard client devices and features
easily deployed fixed infrastructure nodes.
The AP 7181 is also designed to meet the needs of large outdoor networks. The network
can be configured and managed for optimal performance using the Wireless Manager
(WM) network Management application.
The most current versions of this manual and other AP 7181 documentation can be found
at:
http://motorola.wirelessbroadbandsupport.com/support/mesh/library
1.1 Document Conventions
The following graphical alerts are used in this document to indicate notable situations:
NOTE Tips, hints, or special requirements that you should take note of.
Care is required. Disregarding a caution can result in data loss
!
CAUTION
or equipment malfunction.
WARNING! Indicates a condition or procedure that could result in personal
injury or equipment damage.
8. 2 AP 7181 Access Point: Installation Guide
2 Hardware Installation
An AP 7181 access point installation includes mounting the access point, connecting the
access point to the network, and applying power. Installation procedures vary for different
environments.
2.1 Precautions
Before installing an AP 7181 model access point verify the following:
• Become familiar with grounding requirements (see Grounding Requirements).
• The grounding cable for an AP 7181 must be a #8 gauge (10 mm²) wire cross
section and use a Ring Lug that will fit the M5 Grounding Screw on the bottom of
the unit.
• Verify the environment has a continuous temperature range between -40° C to 55°
C.
AP 7181 devices must be installed by trained professionals familiar with RF planning and
regulatory limits defined by the regulatory bodies of the country where the devices are
being deployed. All common precautions for grounding and ESD (Electrostatic Discharge)
protection should be observed during deployment and installation. AP 7181 devices are
designed to be installed outdoors and must be installed such that no harmful interference
results from device operation.
CAUTION All device wiring must comply with the National Electric code
(NEC) or regulations and procedures defined by the regulatory
! bodies of the country or region where the devices are being
deployed. All local building and structure codes must be
observed.
WARNING! Strictly observe the following Safety Precautions during the AP
7181 Installation Procedure.
9. Hardware Installation 3
• Installations must be performed by professionals who are properly trained and
certified.
• Avoid contact with overhead power lines.
• Take precautions to avoid injury from falling tools and equipment. Crews should
wear hardhats in and around the installation work site.
• Be aware of vehicular traffic in and around the installation work site.
• Do not hold any component containing a radio such that the antenna is very close
to or touching any exposed parts of the body, especially the face or eyes, while
transmitting.
• Do not operate a portable transmitter near unshielded blasting caps or in an
environment where explosives are present unless the transmitter is especially
certified for such use.
2.2 Deployment Guidelines
Observe the following recommended guidelines to help ensure a successful network
deployment:
• Mounting height for network devices should not exceed 30 to 35 feet. Mounting
height should vary to accommodate the topography of the deployment area,
foliage, and other obstructions.
• Devices can be deployed using either the Bottom Mount Installation or the Top
Mount Installation procedure.
• Point-to-Point (PTP (Slave)) or Point-to-Multipoint (PMP (SM)) nodes providing
backhaul should be oriented to point away from AP 7181 antenna panels.
NOTE For more detailed deployment considerations for backhaul, refer
to the Mesh AP 7181 System Planner.
• Custom stand-off brackets should be used as required to provide adequate pole
separation in an effort to minimize reflective received power.
• LoS guidelines should be given special consideration whenever devices will not be
installed in a straight line, such as deploying devices on alternating sides of a
roadway.
10. 4 AP 7181 Access Point: Installation Guide
• Ensure that all Root nodes are deployed with line of site to the wireless backhaul
cluster points.
2.3 Installation Methodology
Consideration of the order in which units are installed when deploying an AP 7181 wireless
network can work to ensure a more stable and functional network. The PTP backhaul layer
should be deployed first. Next deploy all nodes for the PMP Access Point distribution layer.
Next deploy Root nodes along with PMP Subscriber Modules (SMs) such that backhaul
and network connectivity can be verified or corrected. Finally, deploy all Mesh Point
wireless nodes in order of the least to most hops (1 hop nodes first, followed by 2 hop nodes,
etc.).
2.4 Grounding Requirements
To avoid damage to the equipment, become familiar with Motorola Policy R56 before
installing AP 7181 units. Refer to Standards and Guidelines For Communication Sites,
Version B. Both the hardcopy manual (Part Number 68P81089E50-B) and the CD version
(Part Number 9880384V83) can be ordered from Motorola.
Section 7.6.4 Broadband - Wireless Access Point Network from the Standards and
Guidelines For Communication Sites applies directly to AP 7181 deployments:
SPD (Surge Protection Device) considerations for broadband shall include the use of SPDs
to protect pole-mounted access points and ground-based cabinet architecture. It is
important to install proper SPD applications on both ends of Ethernet, Power-Over
Ethernet (POE), Giga-Ethernet (GigE) and AC cable runs. SPDs shall be located within
the node or cabinet, or as close to the entrance as possible, and properly installed into load
centers, control panels and utility power cabinets. While RF protection is a consideration,
it shall only be required when antennas are connected to the node with coaxial cables
greater than 610 mm (2 ft.) in length.
The grounding cable for an AP 7181 must be a #8 gauge (10 mm²) wire cross section and
use a Ring Lug that will fit the M5 Grounding Screw on the bottom of the unit.
11. Hardware Installation 5
CAUTION It is required that all root and portal nodes be adequately
grounded. In addition, all root nodes and portals using the
Ethernet port or attached devices (e.g. a camera) must not only
! be grounded, but they should also include surge suppression
for network reliability. This is particularly important for
network configurations with a public safety component.
2.4.1 Ethernet and Lightning Protection
When installing an AP 7181 Root Node that has a direct connection between the shielded
CAT-5E Ethernet and the wired network, lightning protection should be used on all
Shielded CAT-5E Ethernet connections.
An outdoor rated Lightning Protection Unit (LPU) kit such as the Motorola PTP
WB2978AA or the HyperLink AL-CAT6HPJW Lightning Protector should be used. For
more information on Motorola’s PTP Lightning Protection Unit, refer to the PTP-LPU
Technical Specifications.
12. 6 AP 7181 Access Point: Installation Guide
2.4.2 Ethernet and Lightning Protection
NOTE Lightning damage is not covered under the conditions of a
standard Motorola product warranty. When installed correctly,
LPUs provide the best protection from the harmful effects of
lightning. Observe all regional and national codes that apply to
grounding for lightning protection.
2.4.3 AP 7181 Grounding Hardware and Connections
The grounding cable for an AP 7181 must be a #8 gauge (10 mm²) wire cross section and
use a Ring Lug that will fit the M5 Grounding Screw on the bottom of the unit (see AP 7181
Connections and Ports).
The Grounding Screw is shown below in green.
When connecting the grounding cable to the unit, tighten the Grounding Screw to between
21.9 and 29.2 inch pounds (lbf-in).
13. Hardware Installation 7
Access points mounted on a metallic pole should be grounded as shown in the following
figure.
14. 8 AP 7181 Access Point: Installation Guide
Access points mounted on a nonmetallic pole should be grounded as shown in the following
figure.
When grounding a unit installed on a nonmetallic pole, a ground conductor and rod is
required. This requirement should be factored into the project deployment costs,
particularly if the equipment must be installed by a utility company.
When grounding a unit installed on a wooden pole, a ground conductor and rod is required.
This requirement should be factored into the project deployment costs, particularly if the
equipment must be installed by a utility company.
15. Hardware Installation 9
2.5 Minimum Installation Requirements
The minimum requirements for installing an AP 7181:
• AP 7181 Access Point
• Power Cable (Flying Leads)
• Standard Ethernet cable
• Yoke (attached)
• 22 mm Socket and driver to remove port caps
• #6 metric Allen wrench to remove the Yoke
2.6 Package Contents
Check the package contents for the AP 7181. Each unit should contain:
• AP 7181 Access Point (assembled with Mounting Yoke attached)
• Power Cable
• Optional accessories (in a separate box inside the AP 7181 shipping container)
Contact the Motorola Support Center to report missing or improperly functioning items.
Refer to Customer Support.
2.7 Access Point Placement
Typically, roadways in the deployment area become main arteries for the wireless mesh
network. Roadways can provide LoS coverage over large distances between Root and Non
Root APs.
2.7.1 Site Surveys
Motorola recommends conducting a site survey prior to installing an access point. A
thorough site survey must include a visit to the customer site to identify the characteristics
of the coverage area, including availability of electrical distribution for power sources and
the location of existing network infrastructure.The site survey should also include
preliminary WLAN measurements to identify candidate AP locations
When scheduling a visit to conduct a site survey, request access to wiring closets, adjacent
floors, and other locations that may require special permission.
16. 10 AP 7181 Access Point: Installation Guide
2.7.2 Root Node Placement
When planning for Root Node placement:
• Identify Root node wireless backhaul technology (Point-to-Point (PTP), Point-
to-Multipoint (PMP)).
• Identify Ethernet or fiber optic backhaul.
• Identify Root node locations.
• Obtain all required permits and/or lease agreements.
• Verify that power is available at each potential node deployment location.
• Give careful consideration to the fact that Root nodes with a wireless backhaul
usually backhaul traffic to a cluster point (i.e. PMP Canopy).
• Wireless backhaul clusters can be on towers, rooftops, etc.
• Ensure that all Root nodes are deployed with LoS to cluster points.
When installing an AP7181 Root Node that has its Shielded CAT-5E Ethernet directly
connected to the wired network Lightning protection should be used on all Shielded
CAT-5E Ethernet connections. An outdoor rated Lightning Protection Unit kit such as
the Motorola PTP WB2978AA or the HyperLink AL-CAT6HPJW Lightning Protector
should be used. For more information on Motorola's PTP Lightning Protection Unit,
refer to the PTP-LPU Technical Specifications.
2.7.3 Non Root Node Placement
The same guidelines as Root nodes apply with the exception of a backhaul requirement
The placement of Non Root nodes will depend heavily on the RF network design.
Consider the guidelines for optimizing wireless network performance when identifying
potential mounting sites.
In addition, consider the following when planning for Non Root node placement:
• Light Poles, Utility Poles, or Traffic Poles
• Obtain all required supplemental agreements from local governments and
utilities.
• Obtain a generic mounting agreement that is not specify specific poles,
since installation locations may need to be modified during deployment.
• Plan for AC power usage of 84 watts average, 126 watts peak.
• The AP 7181 is rated for wind loading of up to160 miles per hour and 30
pounds per square foot.
17. Hardware Installation 11
• Ensure that proper grounding can be established.
• The grounding cable for an AP 7181 must be a #8 gauge (10 mm²) wire cross
section and use a Ring Lug that will fit the M5 Grounding Screw on the bottom
of the unit.
• Rooftops and Towers
• May require lease agreements.
• Identify AP locations based on optimal communication with the Root nodes.
• Non Root node placement will be dependent on asset availability, terrain, etc.
• Ensure that nodes are placed at the same height.
• Build the network outward from each root node, from least to greatest number of
hops.
As with Root nodes, it should be noted that it is incumbent upon the customer to obtain the
required Pole Attachment Agreements for devices to be installed on traffic / utility poles.
Obtaining the agreements can be a lengthy process, so ample lead time must be allowed.
The potential pole locations should be logged with GPS to obtain accurate coordinates.
Also log any identifying numbers on the pole so that this information can be provided to
the appropriate utility agency. Alternate mounting locations should also be identified in the
event that your initial request is denied.
Specialized brackets may be required for attaching devices to decorative light poles and
these brackets may have to be custom fabricated. If this is the case, allow enough lead time
for ordering the proper equipment.
Also consider any requirements to coordinate requests with multiple utility agencies within
the same community. Verify that light pole selections have power available continuously
and that the power source is within the operational range of the device being connected.
2.7.4 Mounting Locations
To avoid distortion of the RF pattern, device locations should be chosen such that the AP
7181 ADvanced Element Panel Technology (ADEPT) antenna panels are at least 30 inches
from any nearby metal poles and not co-located or operating in conjunction with any other
antenna or transmitter.The antenna panels must also have a separation distance of at least 2
meters from anyone who may come into proximity of the AP 7181.
18. 12 AP 7181 Access Point: Installation Guide
2.7.5 Device Deployment Height
AP 7181 nodes are typically mounted at a height of 30 to 35 feet. Ensure that neighboring
nodes are mounted at or near the same device height.
Excessive height should be avoided since this may result in increased congestion and
interference in dense RF environments. This is especially true for the 2.4 GHz band.
Nodes deployed with too great a difference in height or too close to each other may not
mesh properly.
Always consider these general guidelines for device deployment height:
• Maintain a typical deployment height of 30 to 35 feet.
• For optimum performance, ensure that devices are oriented to have LoS to all
neighboring devices.
• Locate Root Nodes which support Wireless Backhaul so that they have LoS to
Backhaul clusters or PTP locations, such as towers.
2.8 Antenna Options
The AP 7181 features an integrated ADvanced Element Panel Technology (ADEPT)
antenna system that is designed to take full advantage of the 802.11n radios. No other
antennas are supported.
2.9 AP 7181 Power Options
Details of the power sourcing equipment for the AP 7181 should be handled by a
professional installer. The requirements for deploying the system are:
• Over current protection device with a maximum rating of 20 Amps.
• AP 7181 AC Model - 100-240 VAC input capable of sourcing 180 watts.
• AP 7181 DC Model - Nominal 48 Volt Power source (41-58 VDC) capable of
sourcing 150 watts. Battery floating voltage should not exceed 60 VDC.
19. Hardware Installation 13
2.9.1 Power Cables
Flying lead power cables are available based on the country of operation.
Four Wire AC Right Angle Power Cable Black (Line)
(North America and International) White (Neutral)
Red (Unused)
Green/Yellow (Ground)
Three Wire AC Power Cable Brown (Line)
(International) Blue (Neutral)
Green/Yellow (Ground)
Two Wire DC Power Cable Black (Negative)
(North America and International) Red (Positive)
Never plug a power cable wired to a power source for an AC
!
CAUTION
unit into a DC unit.
If the units will be plugged directly into an electrical wall outlet, power plug adapters are
available for North America, Europe, and Australia.
CAUTION Do not use the connector on the power cables for
! interrupting current. Never actively plug or unplug the
connector while the cable is energized.
20. 14 AP 7181 Access Point: Installation Guide
2.10 Mounting an AP 7181
The AP 7181 is designed for outdoor installations. All hardware installations should be
performed by a professional installer.
Devices can be deployed using either the Bottom Mount Installation or the Top Mount
Installation procedure.
2.10.1 Pole Mounted Installations
The optional Wall Gooseneck can also be used with the Pole Adapter for pole mounting.
The Wall Gooseneck dimensions are 10x12x6 inches and it weighs 4 pounds. The Pole
Adapter dimensions are 4x2.62x7 inches and it weighs 3 pounds.
The Gooseneck attaches to the Yoke, which can be attached to the top or the bottom of the
AP 7181. Secure the Gooseneck and adaptor to the pole using band clamps with the
threaded portion pointing either up or down.
If using a bottom mount, drill a 1/2 inch diameter hole at the lowest point on the bend to
allow water to drain from the Gooseneck.
21. Hardware Installation 15
2.11 Installing an AP 7181
The following guidelines and procedures should be observed when installing an AP 7181
device.
2.11.1 Required Tools
The following is a list of the minimal tool set required to install an AP 7181 device:
• 24 mm Socket and driver - for cable gland
• 22 mm Socket and driver - for GE1 and GE2 port caps
• 19 mm Socket and driver - for Console port cap
• 21 mm Socket and driver - for Set Screw
• 8 mm Socket and driver - for Grounding Screw
• 6 mm Allen wrench bit - for mounting bracket (Yoke)
• T27 Torx bit - for the Radome Antenna Panels and Sun Shields
• Torque Screwdriver - for the Radome Antenna Panels and Sun Shields
• Torque Wrench
• Adjustable Wrench
• Standard Level
• Anti-seize lubricant
You may also need a Phillips screw driver and a 2.5 mm Allen wrench to perform an
External Hardware Reset.
22. 16 AP 7181 Access Point: Installation Guide
2.11.2 AP 7181 Connections and Ports
The power cable and grounding connections, power indicator light, Ethernet and Reset
ports, and LED Status Panel on the bottom the AP 7181 are shown in the figure below.
NOTE The grounding cable for an AP 7181 must be a #8 gauge (10
mm²) wire cross section and use a Ring Lug that will fit the M5
Grounding Screw on the bottom of the unit.
23. Hardware Installation 17
The two pin DC power connector (phase-in) is shown below. All other connections, ports,
and the LED Status Panel for the are the same.
The Horizontal (HP) and Vertical (VP) connectors for the antenna cables are located on the
top of the AP 7181.
All Radome antenna panel cables are labeled as HP or VP. Attach each cable to the
corresponding connector when performing a Remote Panel Antenna Installation or any
other procedure which requires attaching antenna cables to the connectors.
24. 18 AP 7181 Access Point: Installation Guide
NOTE The connectors on the AP 7181 are Ingress Protection 67 (IP67)
rated. No additional weatherproofing precautions are required.
WARNING! When disconnecting the antenna cables from the unit or
removing an antenna panel and replacing it with a Blank panel,
terminators MUST be placed on the unused horizontal and
vertical connectors on the top of the unit The terminators on the
AP 7181 are Ingress Protection 68 (IP68) rated. No additional
weatherproofing precautions are required.
25. Hardware Installation 19
2.11.3 LED Status Indicator Panel
There are six LEDs on the AP 7181 which can be viewed through the light pipes on
the bottom of the unit.The LEDs have the following display characteristics and
functionality.
LED 4 - 5 LED 5 - 2.4
LED 1 LED 2 LED 3 GHz GHz LED 6
Blinking Green Green Amber Emerald Not used.
Red defines defines defines 5 defines 2.4
indicates normal GE1 normal GE2 GHz radio as GHz radio as
booting. operation. operation. configured. configured.
Solid Red Yellow Yellow
defines a defines a defines a
failure collision. collision.
condition.
White
defines
normal
operation.
2.11.4 External Hardware Reset
An AP 7181 can be physically reset using the Hardware Reset button. The button is located
inside the Reset port on the bottom of the unit.
The Reset button is enabled only after the unit boots up and is running the operational
software. If any of LEDs 2 through 6 are active, it indicates that the unit has booted
successfully and the operational software is running.
To perform an External Hardware Reset:
1. Using a Phillips screwdriver, remove the screw from the external Reset port.
2. Carefully insert a 2.5 mm Allen wrench into the Reset port until you make contact
with the Hardware Reset button.
26. 20 AP 7181 Access Point: Installation Guide
CAUTION The Hardware Reset button is attached to a circuit board inside
! the unit. Insert the Allen wrench carefully to make contact with
the top of the button and avoid touching the circuit board.
3. Gently press and hold the Reset button long enough to reach the desired reset level
listed in the table below. When the button is pressed, LED 1 will change from
WHITE to RED and remain RED until the button has been released.
Reboot To reboot the device, hold the button for less than
APPROXIMATELY 4 seconds. Release the button while only
LED 1 illuminates RED.
Partial Factory Default To reset the device to a partial factory default condition, hold
the button for APPROXIMATELY 4 to 15 seconds. Release the
button after LED 2 and LED 3 illuminate YELLOW.
Full Factory Default To reset the device to a full factory default condition, hold the
button for longer than APPROXIMATELY 15 seconds.
Release the button after LED 2 through LED 6 illuminate
YELLOW.
4. When the Reset button is released, the LEDs will be cleared and the unit will
restart.
5. Monitor the LED Status Indicator panel to confirm that the reset operation was
successful.
27. Hardware Installation 21
2.11.5 Removing the AP 7181 Kit from the Shipping Carton
CAUTION Never lift an AP 7181 using the Radome antenna panels or
! other plastic parts. Always lift the unit by the Yoke or metal
antenna rings.
WARNING! An AP 7181 unit weighs 39 pounds. Use all appropriate cautions
when lifting and consider a two man lift when necessary.
1. Open the shipping carton and remove top packaging material.
28. 22 AP 7181 Access Point: Installation Guide
2. Remove the accessories box from the shipping carton.
In the accessories box, you will find the following items:
• Weatherproof Ethernet Port Adaptor (Cable Gland) (Part number: HKLN4486A)
• Waterproof Console Port Adapter (Part number: HKLN4485A)
• Power Cable (Part number: 30009307001, 30009308001, or 30009315002)
• Sun Shields with Captive Screws (Part number: HKLN4446A)
• Yoke (Mounting Bracket) (Part number: HKLN4484A)
• Set Screw for Yoke (Part of the complete AP 7181 kit)
NOTE Only one Set Screw is included with each AP 7181 kit. If a second
Set Screw is required, purchase an M14x2.0, 20mm stainless steel
Hexagonal screw.
3. Open the plastic bag covering the unit.
4. Roll the plastic bag to the bottom of the shipping carton and using the Yoke or
Antenna Ring, carefully remove the unit from the box. Using this method will help
prevent damage to the antenna assembly.
29. Hardware Installation 23
2.11.6 Staging the Device Prior to Installation
WARNING! An AP 7181 unit weighs 39 pounds. Use all appropriate cautions
when lifting and consider a two man lift when necessary.
1. Place on solid surface with the Yoke facing up.
CAUTION Never lift an AP 7181 using the Radome antenna panels or
! other plastic parts. Always lift the unit by the Yoke or metal
Antenna rings.
2. Using the 6mm Allen wrench, loosen the Allen head bolts to remove the Yoke.
30. 24 AP 7181 Access Point: Installation Guide
3. To gain access to the Ethernet and or console ports you will need to remove the
protective caps. A 22 mm socket will be required to remove the Ethernet port caps
covering Gigabit Ethernet ports GE1 and GE2. A 19 mm socket is required to
remove the console port cap (if required).
4. Using the 22 mm socket remove the port caps for Gigabit Ethernet GE1 and GE2.
5. Remove the cap on the cable gland as shown below.
31. Hardware Installation 25
6. Carefully hand tighten the gland into Gigabit port GE1. Once the gland is snug, use
a 24 mm socket and finishing tighten the gland.
If the node is going to be configured as a Mesh Point Root node (Mesh Point Root nodes
have a direct wired Ethernet connection to the core network or an Ethernet connection to a
wireless backhaul) a cable gland will be required for Gigabit Ethernet port GE1.
32. 26 AP 7181 Access Point: Installation Guide
If the Mesh Point Root node is also going to have an external device attached (e.g.
surveillance camera) an additional cable gland will be required for Gigabit Ethernet port
GE2 (make sure the WAN port GE2 has been configured to permit an attached external
device during the configuration process).
NOTE The AP 7181 supports 802.af compliant Power over Ethernet
(PoE) on Ethernet port GE1 and can provide power to an external
PoE capable device such as a surveillance camera. PoE is auto
sensing and is enabled when the AP-7181 senses a PoE capable
device.
33. Hardware Installation 27
If the device being staged is a Mesh Point node (no wired connection to the core network)
and no external device is going to be attached then no cable glands are required.
If the Mesh Point node is going to have an external device attached (e.g. surveillance
camera) a cable gland is required for Gigabit Ethernet port GE1.
34. 28 AP 7181 Access Point: Installation Guide
7. Repeat the process if a second cable gland is required.
8. Attach an Ethernet cable to Gigabit Ethernet port GE2 (to be used with an external
laptop for configuring the unit). You will also need to terminate the flying lead
power cable with the proper plug (for the country of operation) so the unit can be
powered for configuration. After preparing the power cable attach the cable to the
power port. Notice that the power connector is keyed. Next configure the unit.
Refer to Getting Started for initial device configuration.
35. Hardware Installation 29
9. After the unit has been configured, if the GE2 port is not going to be used to attach
an external device to the AP7181, reattach the port cap. If the GE2 port is going to
be used to attach and external device, attach the cable gland to the GE2 port.
10. Reattach the Yoke.
11. Return the unit to the shipping carton for transport to the installation site. Due to
the nature of the electronic components and antenna array, using the shipping
carton is the most secure method for transport.
36. 30 AP 7181 Access Point: Installation Guide
2.12 Field Installation
Observe the following precautions to avoid damage to the unit
!
CAUTION
during installation.
• Only trained and qualified personnel should install this equipment.
• Only a licensed electrician should install power cable / energize circuits.
• All device wiring must follow the National Electric Code (NEC) or wiring
requirements in the country of installation. All location building and structure
codes must be observed.
• Ensure that the power source for the AP 7181 is de-energized prior to installation.
WARNING! Observe the following safety precautions to avoid personal
injury during installation.
• Avoid exposure to high voltage power sources.
• Avoid contact with overhead power lines.
• Avoid falling tools or equipment.
• Be aware of vehicular traffic in the vicinity of the work area.
WARNING! When disconnecting the antenna cables from the unit or
removing an antenna panel and replacing it with a Blank panel,
terminators MUST be placed on the unused connectors on the
top of the unit. The terminators for the AP 7181 are Ingress
Protection 68 (IP68) rated. No additional weatherproofing
precautions are required.
37. Hardware Installation 31
2.12.1 Bottom Mount Installation
The pole mount adapter (Part Number RLN6197A) will accommodate a banding strap up
to 1¼ inch width. Banding straps and the banding tool are not included when ordering the
pole mount adapter.
The pole mount adapter can be mounted to poles 3 inches to 15 inches in diameter and has
a load rating of 75 lbs.
1. Attach the pole mount adapter (or other mounting bracket hardware) to the
mounting asset and ensure that the mounting bracket is level.
NOTE If using a bottom mount, drill a 1/2 inch diameter hole at the
lowest point on the bend to allow water to drain from the
Gooseneck.Installing an AP 7181.
2. Using the 4 hex head bolts (3/8"x16"x1") included with pole mount adapter (Part
Number RLN6197A), secure the Gooseneck to the pole mount adapter.
38. 32 AP 7181 Access Point: Installation Guide
NOTE It is recommended to apply a small tube of anti-seize lubricant to
the threads of the gooseneck to prevent corrosion and seizing.
This will facilitate the mounting process and assure easier
disassembly if the unit needs to be serviced.
3. Grasp the Yoke and carefully remove the unit from the shipping carton.
4. Place the unit on a solid surface with the Yoke facing up.
5. Remove the Yoke and the Allen socket head screws from the bottomof the unit.
6. Attach the Yoke to the Gooseneck by rotating the device counter clockwise for a
minimum of four turns.
WARNING! Carefully align the Yoke with the Mounting Bracket to avoid
cross threading.
7. Ensure that the Yoke and the Mounting Bracket are level.
8. Loosely attach the Allen socket head screws to the unit. Leave the screws loose
enough to attach the Yoke.
39. Hardware Installation 33
9. Carefully lift the unit into position, aligning the key slots for the Yoke with the
Allen socket head screws and slide the Yoke to the final position.
WARNING! An AP 7181 unit weighs 39 pounds. Use all appropriate cautions
when lifting and consider a two man lift when necessary.
10. Torque the Allen socket head screws to between 108.7 and 145.0 Inch Pounds (lbf-
in).
Ensure that the Allen socket hex screws are tight and in the
!
CAUTION
locked position before releasing the full weight of the unit.
40. 34 AP 7181 Access Point: Installation Guide
11. The Set Screw can now be inserted to increase stability. Tighten the Set Screw to
between 214.2 and 250.0 inch pounds (lbf-in).
NOTE Only one Set Screw is included with each AP 7181 kit. If a second
Set Screw is required, purchase an M14x2.0, 20mm stainless steel
Hexagonal screw.
12. If the AP 7181 you are mounting is a Mesh Point Root node or a Mesh Point node
with an external device (e.g. surveillance camera) perform the required Ethernet
cabling.
The Ethernet cable gland is optimized for cables of diameter .39 to .55 inches. Smaller
diameter cables can achieve a watertight seal if the cable gland is properly tightened during
installation. It is recommended that an Outdoor- UV Rated, shielded cable is used in AP
7181 deployments. Some examples are:
• Superior Essex 04-001-55
• Best-Tronics BT-0562
In most cases Ethernet cable will need to be custom cut to length. After preparing the
Ethernet cable and attaching shielded RJ-45 end connectors feed the cable through the cable
gland cap and rubber insert as shown below.
41. Hardware Installation 35
13. Insert data cable through cable gland (i.e. the cable gland on Gigabit Ethernet port
GE1)
a. Connect the RJ45 Ethernet cable to the Ethernet port.
b. Hand tighten the cap for the cable gland.
c. Using an adjustable wrench, tighten the cable grip until it fits snugly around the
Ethernet cable.
d. Repeat the process for additional Ethernet connections if required.
42. 36 AP 7181 Access Point: Installation Guide
Observe the following precautions to avoid damage to the unit
!
CAUTION
during installation.
• Only trained and qualified personnel should install this equipment.
• Only a licensed electrician should install power cable / energize circuits.
• All device wiring must follow the National Electric Code (NEC) or wiring
requirements in the country of installation. All location building and structure
codes must be observed.
• Ensure that the power source for the AP 7181 is de-energized prior to installation.
WARNING! Observe the following safety precautions to avoid personal
injury during installation.
• Avoid exposure to high voltage power sources.
• Avoid contact with overhead power lines.
• Avoid falling tools or equipment.
• Be aware of vehicular traffic in the vicinity of the work area.
The power cable included with the AP 7181 is a flying lead cable. Most installations will
require the installer to install an additional power cable.
The AP 7181 flying lead power cables are 12 feet long. The installer should splice the
power cable to the AP 7181 flying lead cable in accordance to the National Electric Code
(NEC) or wiring requirements in the country of operation. Only outdoor rated power cable
should be used.
AC versions of the AP 7181 require an input voltage of 100 -
!
CAUTION
240 VAC. DC versions require an input voltage of 41-58 VDC.
43. Hardware Installation 37
14. Once the power cable has been prepared, connect the power cable to the unit.
15. The unit must be grounded according to the Motorola R56 2005 Manual for
Standards and Guidelines for Communication Sites (see Grounding Requirements).
The grounding cable for an AP 7181 must be a #8 gauge (10 mm²) wire cross
section and use a Ring Lug that will fit the M5 Grounding Screw on the bottom of
the unit.
The Grounding Screw is shown below in green. When connecting the grounding
cable to the unit, tighten the Grounding Screw to between 21.9 and 29.2 inch
pounds (lbf-in).
44. 38 AP 7181 Access Point: Installation Guide
16. Secure and conceal the cables using UV resistant tie wraps. Tie wraps should be
used to secure the cables along the Gooseneck.
17. If desired, attach the sun shields to the top/bottom using the captive screws. If
attaching the sun shields to the bottom of the unit, first remove the knock out discs
in the center to fit around the Yoke. Tighten the captive screws to between 39.9 and
53.1 inch pounds (lbf-in).
18. Once physical installation is completed the circuit powering the AP 7181 can be
energized. Verify that the green power LED is illluminated and the unit is powered
on.
45. Hardware Installation 39
2.12.2 Top Mount Installation
1. Grasp the Yoke and carefully remove the unit from the shipping carton.
2. Place the unit on a solid surface with the Yoke facing up.
3. Remove the Yoke and the Allen socket head screws from the bottom of the unit.
The pole mount adapter (Part Number RLN6197A) will accommodate a banding strap up
to 1¼ inch width. Banding straps and the banding tool are not included when ordering the
pole mount adapter.
The pole mount adapter can be mounted to poles from 3 inches to 15 inches in diameter and
has a load rating of 75 lbs.
46. 40 AP 7181 Access Point: Installation Guide
4. Attach the pole mount adapter (or other mounting bracket hardware) to the
mounting asset and ensure that the mounting bracket is level.
5. Using the 4 hex head bolts (3/8"x16"x1") included with pole mount adapter (Part
Number RLN6197A), secure the Gooseneck to the pole mount adapter.
NOTE It is recommended to apply a small tube of anti-seize lubricant to
the threads of the gooseneck to prevent corrosion and seizing.
This will facilitate the mounting process and assure easier
disassembly if the unit needs to be serviced.
47. Hardware Installation 41
6. Attach the Yoke to the Gooseneck by rotating the device counter clockwise for a
minimum of four turns.
WARNING! Carefully align the Yoke with the Mounting Bracket to avoid
cross threading.
7. Ensure that the Yoke and the Mounting Bracket are level.
8. Loosely attach the Allen socket head screws to the top of the unit. Leave the screws
loose enough to attach the Yoke.
WARNING! An AP 7181 unit weighs 39 pounds. Use all appropriate cautions
when lifting and consider a two man lift when necessary.
48. 42 AP 7181 Access Point: Installation Guide
9. Carefully lift the unit into position, aligning the key slots for the Yoke with the
Allen socket head screws and slide the Yoke to the final position.
Ensure that the Allen socket hex screws are tight and in the
!
CAUTION
locked position before releasing the full weight of the unit.
10. Torque the Allen socket head screws to between 108.7 and 145.0 Inch Pounds (lbf-
in).
11. The Set Screw can now be inserted to increase stability. Using a 21mm socket with
torque wrench, tighten the Set Screw to between 214.2 and 250.0 Inch Pounds (lbf-
in).
49. Hardware Installation 43
NOTE Only one Set Screw is included with each AP 7181 kit. If a second
Set Screw is required, purchase an M14x2.0, 20mm stainless steel
Hexagonal screw.
12. If the AP 7181 you are mounting is a Mesh Point Root node or a Mesh Point node
with an external device (e.g. surveillance camera) perform the required Ethernet
cabling.
The Ethernet cable gland is optimized for cables of diameter .39 to .55 inches. Smaller
diameter cables can achieve a watertight seal if the cable gland is properly tightened during
installation. It is recommended that an Outdoor- UV Rated, shielded cable is used in AP
7181 deployments. Some examples are:
• Superior Essex 04-001-55
• Best-Tronics BT-0562
In most cases Ethernet cable will need to be custom cut to length. After preparing the
Ethernet cable and attaching shielded RJ-45 end connectors feed the cable through the cable
gland cap and rubber insert as shown below.
50. 44 AP 7181 Access Point: Installation Guide
13. Insert the data cable through cable gland (i.e. the cable gland on Gigabit Ethernet
port GE1).
a. Connect the RJ45 Ethernet cable to the Ethernet port.
b. Hand tighten the cap for the cable gland.
14. Using an adjustable wrench, tighten the cable grip until it fits snugly around the
Ethernet cable.
c. Repeat the process for additional Ethernet connections if required.
51. Hardware Installation 45
Observe the following precautions to avoid damage to the unit
!
CAUTION
during installation.
• Only trained and qualified personnel should install this equipment.
• Only a licensed electrician should install power cable / energize circuits.
• All device wiring must follow the National Electric Code (NEC) or wiring
requirements in the country of installation. All location building and structure
codes must be observed.
• Ensure that the power source for the AP 7181 is de-energized prior to installation.
WARNING! Observe the following safety precautions to avoid personal
injury during installation.
• Avoid exposure to high voltage power sources.
• Avoid contact with overhead power lines.
• Avoid falling tools or equipment.
• Be aware of vehicular traffic in the vicinity of the work area.
The power cable included with the AP 7181 is a flying lead cable. Most installations will
require the installer to install an additional power cable.
The AP 7181 flying lead power cables are 12 feet long. The installer should splice the
power cable to the AP 7181 flying lead cable in accordance to the National Electric Code
(NEC) or wiring requirements in the country of operation. Only outdoor rated power cable
should be used.
AC versions of the AP 7181 require an input voltage of 100-
!
CAUTION
240 VAC. DC versions require an input voltage of 41-58 VDC.
52. 46 AP 7181 Access Point: Installation Guide
15. Once the power cable has been prepared, connect the power cable to the unit.
16. The unit must be grounded according to the Motorola R56 2005 Manual for
Standards and Guidelines for Communication Sites (see Grounding
Requirements). The grounding cable for an AP 7181 must be a #8 gauge (10 mm²)
wire cross section and use a Ring Lug that will fit the M5 Grounding Screw on the
bottom of the unit.
The Grounding Screw is shown below in green. When connecting the grounding
cable to the unit, tighten the Grounding Screw to between 21.9 and 29.2 inch
pounds (lbf-in).
53. Hardware Installation 47
17. Secure and conceal the cables using UV resistant tie wraps. Tie wraps should also
be used to secure the cables along the Gooseneck.
18. If desired, attach the sun shields to the top/bottom using the captive screws. If
attaching the sun shields to the bottom of the unit, first remove the knock out discs
in the center to fit around the Yoke. Tighten the captive screws to between 39.9 and
53.1 inch pounds (lbf-in).
Once physical installation is completed the circuit powering the AP 7181 can be energized.
Verify that the green power LED is illuminated and the unit is powered on.
54. 48 AP 7181 Access Point: Installation Guide
2.13 Remote Panel Antenna Installation
When choosing a deployment location to optimize performance, it may be necessary to
mount a device such that one of the antenna panels may be obstructed. For example, traffic
light poles can completely obscure one of the panels in the AP 7181 antenna array. The
Remote Panel antenna kit can be used to address this use case.
In addition to the standard hardware, the following items are also required for installing a
Remote Panel antenna:
• Antenna Extension Cables (6 or 10 feet)
• ADEPT Panel Remote Mounting Bracket
• Terminators for the Horizontal (HP) and Vertical (VP) antenna connections on the
top of the unit.
NOTE The terminators for the AP 7181 are Ingress Protection 68 (IP68)
rated. No additional weatherproofing precautions are required.
55. Hardware Installation 49
NOTE In addition to the required tools, you will need a cordless and a
3.6 mm bit to pre the hole for the set screw on the ADEPT Panel
Remote Mounting Bracket.
When the Remote Panel antenna installation is used, a Blank antenna panel should be
attached to cover the side of the device facing the obstruction. Using a Blank antenna panel
will help protect the interior of the AP 7181.
Blank antenna panels can also be used when a device is installed directly against a wall or
the side of a building. See Installing the Blank Antenna Panel.
56. 50 AP 7181 Access Point: Installation Guide
WARNING! When disconnecting the antenna cables from the unit or
removing an antenna panel and replacing it with a Blank panel,
terminators MUST be placed on the unused horizontal and
vertical connectors on the top of the unit. The terminators on the
AP 7181 are Ingress Protection 68 (IP68) rated. No additional
weatherproofing precautions are required.
57. Hardware Installation 51
2.13.1 Preparing the AP 7181
To prepare the AP 7181 for installation using the Remote Panel antenna:
1. Remove the screws for one of the four Radome antenna panels.
2. Grasp the lower part (barrel) of the antenna cable connector and carefully detach
the antenna cables from the connectors on the device. Remove the Radome antenna
panel.
58. 52 AP 7181 Access Point: Installation Guide
3. Attach the extension cable for the Remote Antenna panel to the device.
4. Carefully route the extension cable inside the antenna rings on the device.
59. Hardware Installation 53
5. Using the four screws provided, attach a Blank antenna panel to the unit to cover
the side of the device where the functional antenna panel was removed. Adjust the
panel to the desired position. Torque the screws to 60 Inch Pounds (lbf-in).
6. Return the unit to the shipping carton for transportation to the installation site.
7. Collect the Radome panel that was removed from the unit and all other hardware
and tools required for the installation.
2.13.2 Installing the Remote Panel Antenna
To complete the installation of the Remote Panel antenna at the site:
1. At the installation site, install the AP 7181 using the appropriate Field Installation
procedure.
WARNING! DO NOT apply power to the unit until the Remote Panel
installation procedure is complete.
2. Assemble the ADEPT Panel Remote Mounting Bracket using the instruction sheet
supplied with the hardware.
3. Test fit the mounting bracket at the installation site, positioning the bracket so that
when the Remote Panel antenna is attached, it will be oriented to support line-of-
sight communication with other devices.
60. 54 AP 7181 Access Point: Installation Guide
4. Tighten the nuts on the mounting bracket so that the support arm remains in the
desired position.
5. Use a cordless and a 3.6 mm bit to the hole for the set screw on the mounting
bracket.
6. Insert and tighten the M4.8 set screw for the mounting bracket.
7. Using the supplied clamps, attach the Remote Antenna panel to the mounting
bracket.
61. Hardware Installation 55
CAUTION When adjusting the Remote Mount antenna panel on the
mounting bracket, ensure that the mounting bracket does not
! extend past the top of the antenna panel to comply with wind
loading requirements.
8. Complete the installation of the mounting bracket using the appropriate method for
the installation requirements.
9. Attach the extension cable from the AP 7181 to the connectors on the Remote
Mount antenna panel.
NOTE The connectors on the AP 7181 are Ingress Protection 67 (IP67)
rated. No additional weatherproofing precautions are required.
10. Secure the cables to the mounting bracket using UV resistant tie wraps.
NOTE Both 6 and 10 foot extension cables are available. The extension
cables can be configured in a daisy chain if additional length is
required.
11. After the Remote Panel installation is complete, apply power to the AP 7181.
62. 56 AP 7181 Access Point: Installation Guide
2.13.3 Installing the Blank Antenna Panel
In addition to Remote Panel antenna installations, Blank antenna panels can also be used if
the unit is going to be placed directly against a wall or building. The Radome antenna
should be removed and the Blank panel should be attached to side of the unit that will be
facing any obstruction.
63. Hardware Installation 57
WARNING! When disconnecting the antenna cables from the unit or
removing an antenna panel and replacing it with a Blank panel,
terminators MUST be placed on the unused horizontal and
vertical connectors on the top of the unit. The terminators on the
AP 7181 are Ingress Protection 68 (IP68) rated. No additional
weatherproofing precautions are required.
64. 58 AP 7181 Access Point: Installation Guide
To install a Blank antenna panel:
1. Remove the screws for one of the four Radome antenna panels.
2. Grasp the lower part (barrel) of the antenna cable connector and carefully detach
the antenna cables from the connectors on the device. Remove the Radome antenna
panel.
65. Hardware Installation 59
3. Attach the terminators to the antenna cable connectors.
NOTE The terminators for the AP 7181 are Ingress Protection 68 (IP68)
rated. No additional weatherproofing precautions are required.
4. Using the four screws provided, attach a Blank antenna panel to the unit to cover
the side of the device where the functional antenna panel was removed. Adjust the
panel to the desired position. Torque the screws to 60 Inch Pounds (lbf-in).
66. 60 AP 7181 Access Point: Installation Guide
3 Getting Started
Use the following procedures to configure and setup up the AP 7181.
3.1 Initially Connecting to the Access Point
The AP 7181 can be staged and configured using one of several connection techniques.
Managing the access point includes viewing network statistics and setting configuration
options. The access point requires one of the following connection methods to manage the
network:
• Secure Java-Based WEB UI - (use Sun Microsystems JRE 1.5 or higher available
from Sun's Web site. Disable Microsoft's Java Virtual Machine if installed). For
information on using the Web UI to set access point default configuration, refer to
Basic Device Configuration or chapters 4 through 7 of the AP 7181 Access Point
Product Reference Guide.
• Command Line Interface (CLI) via Serial, Telnet and SSH. The access point CLI
is accessed through the RS232 port, via Telnet or SSH. The CLI follows the same
configuration conventions as the device user interface with a few documented
exceptions. For details on using the CLI to manage the access point, refer to chapter
8 of the AP 7181 Access Point Product Reference Guide.
• Config file - Readable text file; Importable/Exportable via FTP, TFTP and HTTP.
Configuration settings for an access point can be downloaded from the current
configuration of another access point meeting the import/export requirements.
67. Getting Started 61
3.1.1 Connecting to the Access Point Using the WAN Port
NOTE These procedures are only valid for initially connecting to an
AP 7181.
To initially connect to the access point using the access point's WAN port:
1. Connect AC power to the access point.
2. The WAN (or GE2) port default is configured with an IP address of 10.1.1.1.
Configure a laptop with an IP address of 10.1.1.2 / 255.0.0.0 and connect to the
GE2 port.
3. Launch a browser and enter the access point's static IP address (10.1.1.1). The
default password is "motorola”.
68. 62 AP 7181 Access Point: Installation Guide
3.1.2 Connecting to the Access Point Using the LAN Port
To initially connect to the access point using the access point's LAN port:
1. The LAN (or GE1/POE) port default is set to DHCP. Connect the access point's
GE1/POE port to an Ethernet segment with access to a DHCP server. The access
point will automatically receive an IP address.
2. To view the IP address, connect one end of a null modem serial cable to the access
point and the other end to the serial port of a computer running HyperTerminal or
similar emulation program
• Configure the following settings:
• Baud Rate - 115200
• Data Bits - 8
• Stop Bits - 1
• No Parity
• No Flow Control
3. Press <ESC> or <Enter> to access the access point CLI.
4. Enter the default username of "admin" and the default password of "motorola."
5. Since this is the first time you are logging into the access point, you will be
prompted to enter a new password and set the county code.
NOTE AP 7181 units configured for deployment in the US will not
prompt the user for a country code.
6. At the CLI prompt (admin>), type "summary."
7. The access point's LAN IP address will be displayed.
8. Connect a laptop on the same Ethernet segment as the access point (e.g. set the
laptop for DHCP so it receives an IP address from the same DHCP server)
69. Getting Started 63
9. Using a Web browser, use the access point's IP address to access the access point.
70. 64 AP 7181 Access Point: Installation Guide
3.2 Basic Device Configuration
For the basic setup described in this section, the Java-based Web UI will be used to
configure the access point. Use the access point's LAN interface for establishing a link with
the access point. Configure the access point as a DHCP client. For optimal screen
resolution, set your screen resolution to 1024 x 768 pixels or greater.
1. Open a browser. If you used the WAN method, point your browser to 10.1.1.1. If
you used the LAN method, point your browser to the IP address provided by the
DHCP server.
NOTE For optimum compatibility, use Java Runtime Environment 1.5 or
higher and disable the Microsoft Java Virtual Machine.
71. Getting Started 65
2. Log in using admin as the default Username and motorola as the default Password.
Use your new password if it has been updated from default.
3. If the default login is successful, the Change Admin Password window displays.
Change the password.
Enter the current password and a new admin password in fields provided. Click Apply.
Once the admin password has been updated, a warning message displays stating the access
point must be set to a country.
The export function will always export the encrypted Admin User password. The import
function will import the Admin Password only if the access point is set to factory default.
If the access point is not configured to factory default settings, the Admin User password
WILL NOT be imported.
NOTE For optimum compatibility, use Java Runtime Environment 1.5 or
higher and disable the Microsoft Java Virtual Machine.
72. 66 AP 7181 Access Point: Installation Guide
3.2.1 Configuring Device Settings
Many of the most important parameter settings located on the configuration pages
throughout the menu tree have been consolidated on the Quick Setup screen to facilitate
getting the unit up and running quickly. Configure a set of minimum required device
settings within the Quick Setup screen. When you change the settings in the Quick Setup
screen, the values also change for other screens where these parameters are displayed.
Additionally, if the values are updated in these other screens, the values initially set within
the Quick Setup screen will be updated.
Basic Settings
To define a basic access point configuration:
1. If the Quick Setup screen is not already displayed, select System Configuration -
> Quick Setup from the menu tree.
2. Enter a System Name for the access point.
The System Name is useful if multiple devices are being administered.
73. Getting Started 67
3. Optionally enter the IP address of the server used to provide system time to the
access point in the Time Server field.
NOTE DNS names are not supported as a valid IP address. The user is
required to enter a numerical IP address.
Once the IP address is entered, the access point's Network Time Protocol (NTP)
functionality is engaged automatically. Refer to the AP 7181 Product Reference
Guide for information on defining alternate time servers and setting a
synchronization interval for the access point to adjust its displayed time and more
detailed information on setting alternate time servers and setting a synchronization
interval for the access point to adjust its displayed time.
4. Enable the radio(s) using the Enable checkbox(es) in the Radio Configuration
field. If using a single radio access point, enable the radio then select either 2.4 GHz
or 5.x GHz from the RF Band of Operation field.
IP Settings
The LAN 1 interface on the AP 7181 supports several different functions. The IP address
assigned to the LAN (by DHCP or via a static address) is the management IP address for
the access point. By default, the LAN 1 interface is tied to physical port GE1 and is
configured for DHCP.
Mesh Point Root nodes are gateway nodes. AP 7181 nodes that are configured as Mesh
Point Roots will utilize the LAN 1 interface (GE1) to connect to the core network.
Nodes that are Non Root Mesh Points also utilize LAN 1 since the IP address of LAN 1 is
the management IP address of the access point. LAN 1 is set to DHCP by default and Non
Root Nodes will receive their IP address over the mesh network. Non Root nodes can also
use GE1 to connect to external devices such as a surveillance camera.
74. 68 AP 7181 Access Point: Installation Guide
To configure the IP Settings:
1. Click the LAN tab to set a minimum set of parameters to use the access point LAN
interface.
2. Select the Enable LAN Interface checkbox to forward data traffic over the access
point's LAN connection. The LAN connection is enabled by default.
3. Use the This interface drop-down menu to specify how network address
information is defined over the access point's LAN connection. Select DHCP
Client if the access points will receive an IP address from the core network via
DHCP. DHCP is a protocol that includes mechanisms for IP address allocation and
delivery of host-specific configuration parameters, such as IP address, network
mask, and gateway, from a DHCP server to a host.
4. Select DHCP Server to use the access point as a DHCP server over the LAN
connection. Select the Bootp client option if network addressing is provided by a
Bootp server.
5. If using the static or DHCP Server option, enter the network-assigned IP Address
of the access point.
6. The Subnet Mask defines the size of the subnet.The first two sets of numbers
specify the network domain. The next set of numbers specifies the subset of hosts
within a larger network. These values help divide a network into sub networks and
simplify routing and data transmission.
75. Getting Started 69
7. If using the static or DHCP Server option, enter a Default Gateway to define the
numerical IP address of a router the access point uses as a default gateway on the
Ethernet.
8. If using the static or DHCP Server option, enter the Primary DNS Server numeric
IP address.
9. If using the DHCP Server option, use the Address Assignment Range parameter
to specify a range of addresses to be reserved for mapping clients to IP addresses.
NOTE If a manually (static) mapped IP address is within the IP address
range specified, that IP address could still be assigned to another
client. To avoid this, ensure all statically mapped IP addresses are
outside of the IP address range assigned to the DHCP server.
WLAN Quick Configuration
The Quick Setup page includes a WLAN section to support WLAN creation. By default, a
single WLAN is configured as ESSID 101, Open, Available on both radios.
1. WLANs 1-4 are available on the Quick Setup screen. Select the WLAN #1 tab to
define its ESSID and security scheme for basic operation.
a. Enter the Extended Services Set Identification (ESSID) and the name
associated with the WLAN. This name is will be identified by 802.11 stations
when searching for a network to connect to.
b. Use the Available On checkboxes to define whether the target WLAN is
operating in the 2.4 or 5.x GHz radio band. Ensure the radio selected has been
enabled.
2. Once the WLAN's radio designations have been made, the radio must be
configured in respect to intended 2.4 or 5 GHz radio traffic and the antennas used.
Select Network Configuration -> Wireless -> Radio Configuration -> Radio1
(or Radio2), and configure the Radio Settings field. If you know the Properties,
Performance and Beacon Settings for the radio, define those fields. Otherwise you
can accept the factory default settings.
3. Define the Channel Settings, Power Level and 802.11 mode with respect to the 2.4
or 5.x GHz 802.11b/g/n or 802.11a/n radio traffic and anticipated gain of the
antennas.
76. 70 AP 7181 Access Point: Installation Guide
CAUTION Only a qualified wireless network administrator should set the
access point radio configuration. Refer to Configuring the
! 802.11a/n or 802.11b/g/n Radio in the AP 7181 Product
Reference Guide for an understanding of configurable radio
values and their implications.
NOTE Even an access point with a minimal configuration must be
protected against data theft and corruption. A security policy
should be configured for WLAN1 as part of the basic
configuration outlined in this guide. A security policy can be
configured for the WLAN using the Quick Setup screen. Policies
can be defined over time and saved to be used as needed as
security requirements change. Motorola recommends that you
familiarize yourself with the security options available on the
access point before defining a security policy. Refer to
Configuring WLAN Security Settings.
4. Click Apply to save any changes to the access point Quick Setup screen.
Dismissing the screen without clicking Apply results in all changes to the screens
being lost.
5. Click Undo Changes to delete any changes made in error. Undo Changes reverts
the settings displayed on the access point Quick Setup screen to the last saved
configuration.
77. Getting Started 71
Removing the WAN Interface from GE2
By default, the WAN interface is enabled and has a static IP address of 10.1.1.1/8. This
interface is tied to physical port GE2 and is used for initial configuration.
In order to use GE2 to connect external devices such as an IP surveillance camera, you will
need to configure the port from a WAN role to a LAN role. This is done by clicking on the
WAN branch under Network Configuration and selecting LAN in the drop down box for
GE2. This will bridge the GE1 and GE2 ports. Any device plugged into GE2 will then be
on the same LAN segment as GE1.
78. 72 AP 7181 Access Point: Installation Guide
To remove the WAN interface from GE2:
1. Select Network Configuration -> WAN from the menu tree.
2. In the Role drop-down box, select LAN.
For more information on WAN port configuration options, refer to Configuring WAN
Settings in the AP 7181 Access Point Product Reference Guide.
79. Getting Started 73
The following diagram illustrates the configuration changes that result from setting the
Role parameter to LAN.
GE1 GE2
LAN1 Bridge WAN Default Configuration
DHCP 10.1. 1.1
IP Stack
GE1 G E2
LAN1 Bridge After changing the role of
GE2 from WAN to LAN
DHCP
IP St ack
80. 74 AP 7181 Access Point: Installation Guide
3.2.2 Configuring WLAN Security Settings
By default the AP 7181 has a default security policy of No Security. In the following
example a WPA2/CCMP security policy will be configured that can be applied to newly
created WLANs.
To configure a basic security policy for a WLAN:
NOTE Even an access point with minimal configuration values must be
protected against data theft and corruption. A security policy
should be configured for WLAN1 as part of the basic
configuration outlined in this guide. A security policy can be
configured for the WLAN from within the Quick Setup screen.
Policies can be defined over time and saved to be used as needed
as security requirements change. Motorola recommends you
familiarize yourself with the security options available on the
access point before defining a security policy.
1. From the access point Quick Setup screen, click the Create button to the right of
the Security Policy item.
2. Ensure the Name of the security policy entered suits the intended configuration or
function of the policy.
CAUTION Multiple WLANs can share the same security policy. Avoid
naming security policies after specific WLANs to eliminate the
! risk of limiting a WLAN to single policy. Motorola
recommends naming the policy after the attributes of the
authentication or encryption type selected.
81. Getting Started 75
3. Select the WPA2/CCMP (802.11i) radio button. The WPA2/CCMP Settings field
is displayed within the New Security Policy screen.
4. Configure the WPA2/CCMP Settings fields as required to define the Pass Key
used to generate the WEP keys.
Key Settings Click the ASCII Passphrase box and enter a passphrase 8 to
63 characters long.
Mixed Mode Under WPA2-CCMP Mixed Mode select the Allow WPA/
WPA2-TKIP clients checkbox to enable support for TKIP
and AES encryption.
5. Click the Apply button to save the security policy and return to the access point
Quick Setup screen.
You can now test the access point for MU (801.11 station) interoperability.
82. 76 AP 7181 Access Point: Installation Guide
3.2.3 Creating a Secure Recovery WLAN
When staging an AP 7181, it is recommended to create a security recovery WLAN to be
used in case the unit becomes unreachable due to errors in configuration or fluctuating
conditions which affect transmission across the wireless network. This is particularly
important if your AP 7181 is addressed via DHCP as the IP address would be lost if a node
became stranded. If the AP 7181 is statically addressed you can connect any configured
WLAN mapped to LAN 1.
1. Click the Enable button next to LAN2 in the LAN branch under Network
Configuration.
After enabling LAN2 you will see an entry for LAN2 under the LAN branch. Select
LAN2. Notice that LAN2 is configured with an IP address of 192.168.1.1
255.255.255.0 by default and is also a DHCP server.
83. Getting Started 77
2. Determine what ESSID (or network name) to use. It is recommended that a unique
ESSID be used for each AP 7181. Since the recovery WLAN is going to be on the
2.4 GHz radio, we chose to use the MAC address of the 2.4 GHz radio. This can be
found by selecting Radio1 [802.11b/g/n] located under Network Configuration -
Wireless - Radio Configuration. The radio MAC address is located in the
properties window. Record this MAC address.
85. Getting Started 79
4. Enter an ESSID. use the MAC address recorded in the previous step.Under
Available On select the 802.11 b/g/n checkbox.
86. 80 AP 7181 Access Point: Installation Guide
5. Select the Security Policy you previously created for WPA2/CCMP. Select the Use
Secure Beacon checkbox to suppress the broadcasting of this network.
6. Click Apply.
7. To map the secure WLAN to LAN2, select Network Configuration -> LAN.
Click WLAN Mapping.
87. Getting Started 81
8. In LAN/VLAN/WLAN Mapping, find the ESSID you created and use the drop-
down box under LAN and select LAN2. Click OK.
9. The LAN Configuration screen will be displayed again. Click Apply.
10. The secure recovery WLAN is now configured. Record the ESSID for future
reference.
88. 82 AP 7181 Access Point: Installation Guide
3.2.4 Testing Connectivity
Verify the access point's link with an MU by sending ping packets to the associated MU.
Use the Echo Test screen to specify a target MU and configure the parameters of the test.
Connect an MU to the hidden recovery WLAN and configure its IP address for DHCP.
NOTE Before testing for connectivity, the target MU needs to be set to
the same ESSID as the access point. Since WPA-PSK security has
been configured on the recovery WLAN for the access point, the
MU will be prompted for a passphrase after associated to the
ESSID.
To test connectivity to a specific MU with an access point:
1. Select Status and Statistics -> MU Stats from the menu tree.
2. Click Echo Test on the MU Stats Summary screen.
3. Define the following parameters for the test.
Station Address The station address is the IP address of the target MU. Refer
to the MU Stats Summary screen for associated MU IP
address information.
Number of pings Defines the number of packets to be transmitted to the MU.
The default is 100.
Pack Length Specifies the length of each packet transmitted to the MU
during the test. The default length is 100 bytes.
4. Click Ping to begin transmitting packets to the specified MU address.
NOTE The Ping test can only be used with Symbol MUs.
5. Refer to the Number of Responses value to assess the number of responses from
the MU versus the number of ping packets transmitted by the access point. Use the
89. Getting Started 83
ratio of packets sent to the number of packets received to determine the link quality
between the MU and the access point.
6. Click OK to exit the Echo Test screen and return to the MU Stats Summary screen.
3.2.5 Creating a Mesh Point
In order for AP 7181s to mesh using MeshConnex, a Mesh Point must be created on each
access point. Once created, mesh points can be applied to either radio (or both). A Root
Mesh Point is an AP 718 connected to the wired network (direct via Ethernet or via a
wireless backhaul).
When configuring a Mesh Point on an AP 7181, you must define whether or not the AP
7181 is a Root Mesh Point. Non Root Mesh Points are simply referred to as Mesh Points.
These Mesh Points are AP 7181's that are not connected to the wired network or wireless
backhaul, although they may still have a camera or other device attached.
In previous Motorola Mesh products Root Mesh Points were referred to as IAPs and Non
Root Mesh Points were referred to as MWRs. An AP 7181 can be configured as either a
Root Mesh Point or a Non Root Mesh Point.
90. 84 AP 7181 Access Point: Installation Guide
To create a Mesh Point:
1. Select Network Configuration -> Wireless -> Radio Configuration -> Radio1
(or Radio2). Confirm that the Channel Selection parameter in the Channel, power
and Rates Settings field is set to Automatic.
91. Getting Started 85
2. Select Network Configuration -> MeshConnex and click Create.
92. 86 AP 7181 Access Point: Installation Guide
7. The New Mesh Point dialog is displayed. Enter a Mesh ID (case-sensitive). This
Mesh ID must be the same on all AP 7181 devices. Next select a radio to mesh on
by selecting the appropriate box under Available On. If this AP 7181 will be
connected to the wired network (Root node / Gateway node) select the Is Root
checkbox.
8. Click Apply to save your settings.
93. Getting Started 87
9. The Mesh Point you created will be displayed in the MeshConnex Configuration
window. Highlight the Mesh Point and click Enable.
10. Repeat the process for each device you are staging.
94. 88 AP 7181 Access Point: Installation Guide
11. To verify that a Mesh has been established, select Status & Statistics ->
MeshConnex Stats and click on the name of the desired Mesh Point.
12. Select the Neighbor tab. In this example, only one neighbor is displayed.
NOTE A neighboring device will not be displayed in the table on the
Neighbor tab if only a single device has been configured. Another
Non-Root device must have already been created and the devices
must be interconnected.
95. Getting Started 89
13. Select the Path tab to see if a route exists for each neighbor. The Path State should
indicate Valid and the Bind State should indicate Bound.
3.3 Where to Go from Here
Once basic connectivity has been verified, the access point can be fully configured to meet
the needs of the network and the users it supports. Refer to the AP 7181 Product Reference
Guide for detailed information on AP 7181 devices in wireless networks.
96. 90 AP 7181 Access Point: Installation Guide
4 Regulatory Compliance
All Motorola devices are designed to be compliant with rules and regulations applicable to the locations where
they are sold and will be labeled as required. Any changes or modifications to Motorola equipment, not
expressly approved by Motorola, could void the user's authority to operate the equipment.
Motorola's devices are professionally installed. The Radio Frequency Output Power will not exceed the
maximum allowable limit for the country of operation.
4.1 Health and Safety Recommendations
The Federal Communications Commission (FCC) with its action in ET Docket 96-8 has adopted a safety
standard for human exposure to radio frequency (RF) electromagnetic energy emitted by FCC certified
equipment. Motorola MOTOMESH products meet the uncontrolled environmental limits found in OET-65 and
ANSI C95.1, 1991. Proper operation of this radio according to the instructions found in this manual and the AP
7181 Product Reference Guide will result in user exposure that is substiually below the FCC recommended
limits.
4.1.1 Warnings for the Use of Wireless Devices
Please observe all warning notices with regard to the usage of wireless devices.
4.1.2 Potentially Hazardous Atmospheres
You are reminded of the need to observe restrictions on the use of radio devices in fuel depots, chemical plants
etc. and areas where the air contains chemicals or particles (such as grain, dust, or metal powders).
4.1.3 Reducing RF Exposure—Use Properly
Only operate the device in accordance with the instructions supplied.
4.2 Power Supply
Use only the Motorola approved power supply output rated at 84 watts average, 126 watts peak. Use of
alternative power supply will invalidate any approval given to this device and may be dangerous.
97. Regulatory Compliance 91
4.3 FCC Regulatory Information
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this device must accept any interference received;
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own expense.
• Do not touch or move the antenna(s) while the unit is transmitting or receiving.
• Do not hold any component containing a radio such that the antenna is very close to or touching any
exposed parts of the body, especially the face or eyes, while transmitting.
• Do not operate a portable transmitter near unshielded blasting caps or in an explosive environment
unless it is a type especially qualified for such use.
• Do not operate the radio or attempt to transmit data unless the antenna is connected; otherwise, the
radio may be damaged.
4.3.1 RF Exposure
This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 20 centimeters between the
radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
The antennas used for this transmitter must be installed to provide a separation distance of at least 20cm from
all persons and must not be located or operating in conjunction with any other antenna or transmitter.
To comply with FCC RF exposure compliance requirements, a separation distance of at least 33.9cm must be
maintained between the user and antenna.
4.3.2 Intentional and Unintentional Radiators
Changes or modifications not expressly approved by Motorola could void the user's authority to operate the
equipment.
4.4 Canada Requirements
This Class B digital apparatus complies with Canadian ICES-003.
For AC powered units use only the Motorola approved internal power supply rated at 48V output. Typical
power is 84 watts average and 126 watts peak. Use of alternative power supply will invalidate any approval
given to this device and may be dangerous.
98. 92 AP 7181 Access Point: Installation Guide
5 Customer Support
5.1 Motorola Mesh Networks Support Web Site
If you have read this document and made every effort to resolve installation or operation
issues yourself and still require support, please contact your regional Motorola support
representatives or visit the Motorola Mesh Networks web site at:
http://www.wirelessbroadbandsupport.com/support/technical.php
5.2 Motorola Mesh Networks Document Library
For the most current version of this manual and other Mesh Networks documentation, visit
the Mesh Networks document library at:
http://www.wirelessbroadbandsupport.com/support/mesh/library
99.
100. MOTOROLA INC
1303 E. ALGONQUIN ROAD
SCHAUMBURG, IL 60196
http://www.motorola.com
39-68009287001
Version 1.0.0.F
October 2010