Annual Maintenance Contract

Reliable Annual Maintenance Contract (AMC) is provided
to various Electrical systems like Substations, Switchyards and
HV & LV Switchgears. We offer Maintenance / Development
plans, Energy Saving plans, Site visits, Need assessment,
Competitive proposal and quotations to our clients.
What is Maintenance?
The entire production will be stopped when any
switchgear fails in the factory; hence by doing proper
cleaning, servicing and retrofitting it ensures increase
in efficiency of the panels as well as gives the required
output.
Why?
We have a team made up of Experienced Professionals and
Technicians each in maintaining the electrical equipment in
an efficient manner.

1. Excellence in engineering & electrical industry, We
designs projects, testing and commissioning of panels.
2. Annual Maintenance Contract (AMC) can be provided in
following terms as Monthly, Quarterly, Half yearly or Yearly
basis, which provides optimal solutions to customer
application needs.
Field Service:
 Significantly reduce unscheduled power outages
 Detecting problems quickly, without interrupting

service
 Minimize preventive maintenance and troubleshooting
time
 Comply with insurance company requirements
 To minimize project cycle time and optimize life cycle
cost by trouble free operation of the system
maintaining zero breakdown hour.
Electrical Tests & Visual Inspections
 Electrical inspection including complete substation













Switchgear, Breakers, Transformers ,Capacitor Banks etc
Electrical Distribution - Overhead lines
Electrical Motor Inspections
Generator Testing & Inspection
Battery Load Testing
Power Factor Testing (doble)
Grounding & Earth Resistance Testing
Motor Testing & Surge Analysis
Variable Frequency Drive testing
Circuit Breaker and Transformer Bushing Replacement,
Repair or Retrofitting
Emergency Transfer Switch Testing, Maintenance or Repair
Cable Testing, Connection tightness & Cable Fault Locating
Bus-duct testing, Power Control Centre maintenance
Meter Calibration & Repair

 We measures and calibrates various instrumentation

including Ammeters and Voltmeters according to
industry standards with specified tolerances. Includes
external cleaning and minor adjustments when necessary
to meet specified tolerances.
Dielectric Fluid Sampling & Analysis

A Dissolved Gas Analysis can provide:
 Indication of an ongoing problem
 Prevention of a serious occurrence such as explosion or sudden outage
 A determination of the improper use of the apparatus tested
 Status checks on new and repaired units
 Distinguish the fault processes like Corona, Sparking, Overheating and
Arcing occurring in the Transformer.
Harmonic Analysis
 Using state of the art equipment, We able to locate and

evaluate these harmonics and then determine if these
harmonics are acceptable in the power system or if
there are problems being caused by these harmonics.
Arc Flash Analysis

 Are your plants’ various power distribution systems in

compliance with the National Electrical Code rules on Arc Flash
Hazards? Find out through an Arc Flash Hazard Analysis.
An Arc Flash Hazard Analysis will:
1. Reduce Arc Flash injuries
2. Increase Personnel
3. Safety Provide NEC and OSHA compliance
4. Help avoid costly fines and litigation
Thank You

For Annual Maintenance Contract, Contact: Arunnun Loganathan
Email: arunnun@yahoo.com
Mobile: +91-9686601807,9442373127

Amc presentation

  • 1.
    Annual Maintenance Contract ReliableAnnual Maintenance Contract (AMC) is provided to various Electrical systems like Substations, Switchyards and HV & LV Switchgears. We offer Maintenance / Development plans, Energy Saving plans, Site visits, Need assessment, Competitive proposal and quotations to our clients.
  • 2.
    What is Maintenance? Theentire production will be stopped when any switchgear fails in the factory; hence by doing proper cleaning, servicing and retrofitting it ensures increase in efficiency of the panels as well as gives the required output.
  • 3.
    Why? We have ateam made up of Experienced Professionals and Technicians each in maintaining the electrical equipment in an efficient manner. 1. Excellence in engineering & electrical industry, We designs projects, testing and commissioning of panels. 2. Annual Maintenance Contract (AMC) can be provided in following terms as Monthly, Quarterly, Half yearly or Yearly basis, which provides optimal solutions to customer application needs.
  • 4.
    Field Service:  Significantlyreduce unscheduled power outages  Detecting problems quickly, without interrupting service  Minimize preventive maintenance and troubleshooting time  Comply with insurance company requirements  To minimize project cycle time and optimize life cycle cost by trouble free operation of the system maintaining zero breakdown hour.
  • 5.
    Electrical Tests &Visual Inspections  Electrical inspection including complete substation             Switchgear, Breakers, Transformers ,Capacitor Banks etc Electrical Distribution - Overhead lines Electrical Motor Inspections Generator Testing & Inspection Battery Load Testing Power Factor Testing (doble) Grounding & Earth Resistance Testing Motor Testing & Surge Analysis Variable Frequency Drive testing Circuit Breaker and Transformer Bushing Replacement, Repair or Retrofitting Emergency Transfer Switch Testing, Maintenance or Repair Cable Testing, Connection tightness & Cable Fault Locating Bus-duct testing, Power Control Centre maintenance
  • 6.
    Meter Calibration &Repair  We measures and calibrates various instrumentation including Ammeters and Voltmeters according to industry standards with specified tolerances. Includes external cleaning and minor adjustments when necessary to meet specified tolerances.
  • 7.
    Dielectric Fluid Sampling& Analysis A Dissolved Gas Analysis can provide:  Indication of an ongoing problem  Prevention of a serious occurrence such as explosion or sudden outage  A determination of the improper use of the apparatus tested  Status checks on new and repaired units  Distinguish the fault processes like Corona, Sparking, Overheating and Arcing occurring in the Transformer.
  • 8.
    Harmonic Analysis  Usingstate of the art equipment, We able to locate and evaluate these harmonics and then determine if these harmonics are acceptable in the power system or if there are problems being caused by these harmonics.
  • 9.
    Arc Flash Analysis Are your plants’ various power distribution systems in compliance with the National Electrical Code rules on Arc Flash Hazards? Find out through an Arc Flash Hazard Analysis. An Arc Flash Hazard Analysis will: 1. Reduce Arc Flash injuries 2. Increase Personnel 3. Safety Provide NEC and OSHA compliance 4. Help avoid costly fines and litigation
  • 11.
    Thank You For AnnualMaintenance Contract, Contact: Arunnun Loganathan Email: arunnun@yahoo.com Mobile: +91-9686601807,9442373127