This document provides a user guide for the Dyna Graze HO Exterior DMX, an outdoor LED lighting fixture. It includes 3 sections: Introduction, Installation, and Operation. The Introduction provides an overview of the fixture, its components, mounting options, and control features. The Installation section covers physical mounting, wiring for power and DMX control, and connecting multiple fixtures together. The Operation section explains how to address the fixtures, select operating modes, and test the LED emitters using an external DMX/RDM controller.
Nexans Euromold Connectors Interface D 600 Series
Nexans Euromold 675LR Connector
1250A 11kV Dead Break Connectors 35-800sqmm
Nexans Euromold 675LR connector suits 11kV/12kV polymeric insulated cables (XLPE EPR), rated up to 1250amps with copper or aluminium conductors 35-800sqmm.
Interface type D Nexans Euromold 5/8" bolted tee connector, for high voltage cable connecting and termination applications up to 24kV. 1250amp (copper stud) application separable connector is designed to connect polymeric (XLPE EPR) cables to a 5/8" copper, 600 series bushings.
Nexans Euromold 600 series screened separable connectors are EPDM pre-moulded, high voltage cable terminations for 6.6kV, 11kV, 15kV and 24kV electrical equipment including switchgear, transformers and motors.
Nexans Euromold 600 series separable connectors include Nexans Euromold bolted tee connectors and Nexans Euromold bushings (oil and air insulated) for electrical equipment up to 24kV - 1250A. Nexans Euromold 600 series connectors are specified to terminate and connect polymeric (XLPE or EPR) screened (copper tape and wire) cables to ANSI-style Interface Type D (800amp) bushings with either copper or aluminium 5/8" bolted connection.
Abb Combiflex Lugs 1.5, Abb Combiflex Lugs 2.5 | AKBAR TRADING EST. JUBAILAKBAR TRADING
Contact sockets, silver plated (set of 100 pcs)
10 A, conductor area 0,25-1,5 mm2
20 A, conductor area 1,5-2,5 mm2
1
1
1MRK 002 136-A
1MRK 002 136-D
50 g
90 g
Contact pins, silver plated (set of 100 pcs)
10 A, conductor area 0,25-1,5 mm2
20 A, conductor area 1,5-2,5 mm2
1
1
1MRK 002 136-G
1MRK 002 136-H
60 g
120 g
Nexans Euromold Connectors Interface D 600 Series
Nexans Euromold 675LR Connector
1250A 11kV Dead Break Connectors 35-800sqmm
Nexans Euromold 675LR connector suits 11kV/12kV polymeric insulated cables (XLPE EPR), rated up to 1250amps with copper or aluminium conductors 35-800sqmm.
Interface type D Nexans Euromold 5/8" bolted tee connector, for high voltage cable connecting and termination applications up to 24kV. 1250amp (copper stud) application separable connector is designed to connect polymeric (XLPE EPR) cables to a 5/8" copper, 600 series bushings.
Nexans Euromold 600 series screened separable connectors are EPDM pre-moulded, high voltage cable terminations for 6.6kV, 11kV, 15kV and 24kV electrical equipment including switchgear, transformers and motors.
Nexans Euromold 600 series separable connectors include Nexans Euromold bolted tee connectors and Nexans Euromold bushings (oil and air insulated) for electrical equipment up to 24kV - 1250A. Nexans Euromold 600 series connectors are specified to terminate and connect polymeric (XLPE or EPR) screened (copper tape and wire) cables to ANSI-style Interface Type D (800amp) bushings with either copper or aluminium 5/8" bolted connection.
Abb Combiflex Lugs 1.5, Abb Combiflex Lugs 2.5 | AKBAR TRADING EST. JUBAILAKBAR TRADING
Contact sockets, silver plated (set of 100 pcs)
10 A, conductor area 0,25-1,5 mm2
20 A, conductor area 1,5-2,5 mm2
1
1
1MRK 002 136-A
1MRK 002 136-D
50 g
90 g
Contact pins, silver plated (set of 100 pcs)
10 A, conductor area 0,25-1,5 mm2
20 A, conductor area 1,5-2,5 mm2
1
1
1MRK 002 136-G
1MRK 002 136-H
60 g
120 g
Straight and right angled bushing boots from stock suit switchgear and transformer bushings - bushing boots provide high voltage electrical insulation, preventing flashover caused by moisture ingress, industrial contamination, high humidity and rodents.
High Voltage 33kV Bushing Boots (RABK/STBK)
The high voltage bushing diameters on a 33kV switchgear or transformer system are normally in excess of 100mm in diameter so a standard boot is unsuitable. 33kV insulating boots are ex stock.
Heat shrink cable joints to suit PVC, EPR (BS6883) and XLPE (BS5467) multi-core cables up to 3.3kV - the heat shrink cable joint comprises of adhesive lined connector insulation tubes, heavy duty steel wire armour earth cage, armour support rings and clamps and an outer thick wall adhesive lined heat shrink tube.
SPS Heat Shrink Cable Joints & Cable Terminations - Quality Performance Testing : Shrink Polymer Systems heat shrink cable joints and cable termination kits are tested to BS7888 which incorporates Cenelec Standards HD 628 S1 and 629.1 S2 : 2006, DIN VDE0279 and IEC60502.
CÔNG TY CỔ PHẦN THIẾT BỊ ĐIỆN HOÀNG PHƯƠNG
Địa chỉ: Số 10, ngõ 44, phố Võ Thị Sáu, P.Thanh Nhàn, Q.Hai Bà Trưng, TP. Hà Nội
MST: 0106798886
Điện thoại: 024.3215.1322
Website : Hoangphuongjsc.com
Phone/Zalo : 0944 240 317 / Kinhdoanh1.hpe@gmail.com
Phone/Zalo : 0975 123 698 / Kinhdoanh2.hpe@gmail.com
Phone/Zalo : 0961 008 858 / Kinhdoanh3.hpe@gmail.com
Nexans Euromold Connectors Interface D 600 Series
Nexans Euromold 650LR Connector
800A 11kV Dead Break Connectors 35-630sqmm
Interface type D Nexans Euromold 5/8" bolted tee connector, for high voltage cable connecting and termination applications up to 24kV. 800amp (aluminium stud) application separable connector is designed to connect polymeric (XLPE EPR) cables to a 5/8" aluminium stud, 600 series bushings.
Nexans Euromold K650LR connector suits 24kV polymeric insulated cables (XLPE EPR), rated up to 800amps with copper or aluminium conductors 35-630sqmm.
Interface type D Nexans Euromold 5/8" bolted tee connector, for high voltage cable connecting and termination applications up to 24kV. 800amp (aluminium stud) application separable Nexans Euromold connector is designed to connect polymeric (XLPE EPR) cables to a 5/8" aluminium stud, 600 series bushings.
Straight and right angled bushing boots from stock suit switchgear and transformer bushings - bushing boots provide high voltage electrical insulation, preventing flashover caused by moisture ingress, industrial contamination, high humidity and rodents.
High Voltage 33kV Bushing Boots (RABK/STBK)
The high voltage bushing diameters on a 33kV switchgear or transformer system are normally in excess of 100mm in diameter so a standard boot is unsuitable. 33kV insulating boots are ex stock.
Heat shrink cable joints to suit PVC, EPR (BS6883) and XLPE (BS5467) multi-core cables up to 3.3kV - the heat shrink cable joint comprises of adhesive lined connector insulation tubes, heavy duty steel wire armour earth cage, armour support rings and clamps and an outer thick wall adhesive lined heat shrink tube.
SPS Heat Shrink Cable Joints & Cable Terminations - Quality Performance Testing : Shrink Polymer Systems heat shrink cable joints and cable termination kits are tested to BS7888 which incorporates Cenelec Standards HD 628 S1 and 629.1 S2 : 2006, DIN VDE0279 and IEC60502.
CÔNG TY CỔ PHẦN THIẾT BỊ ĐIỆN HOÀNG PHƯƠNG
Địa chỉ: Số 10, ngõ 44, phố Võ Thị Sáu, P.Thanh Nhàn, Q.Hai Bà Trưng, TP. Hà Nội
MST: 0106798886
Điện thoại: 024.3215.1322
Website : Hoangphuongjsc.com
Phone/Zalo : 0944 240 317 / Kinhdoanh1.hpe@gmail.com
Phone/Zalo : 0975 123 698 / Kinhdoanh2.hpe@gmail.com
Phone/Zalo : 0961 008 858 / Kinhdoanh3.hpe@gmail.com
Nexans Euromold Connectors Interface D 600 Series
Nexans Euromold 650LR Connector
800A 11kV Dead Break Connectors 35-630sqmm
Interface type D Nexans Euromold 5/8" bolted tee connector, for high voltage cable connecting and termination applications up to 24kV. 800amp (aluminium stud) application separable connector is designed to connect polymeric (XLPE EPR) cables to a 5/8" aluminium stud, 600 series bushings.
Nexans Euromold K650LR connector suits 24kV polymeric insulated cables (XLPE EPR), rated up to 800amps with copper or aluminium conductors 35-630sqmm.
Interface type D Nexans Euromold 5/8" bolted tee connector, for high voltage cable connecting and termination applications up to 24kV. 800amp (aluminium stud) application separable Nexans Euromold connector is designed to connect polymeric (XLPE EPR) cables to a 5/8" aluminium stud, 600 series bushings.
The range
An operator system cannot be said to be complete without a flashing light that warns when the gate or door is moving, to ensure maximum safety for users. Came's offer meets all needs in terms of reliability, design, energy
savings, and always in compliance with European Regulations.
Traxon Cove Light AC HO RGBW Specificationvalorlighting
The Cove Light AC HO RGB Graze is a slim profile, AC line powered high brightness luminaire. The luminaire is controllable via DMX512 and perfect for alcove applications. The simplicity of the luminaire’s topology means it can be simply daisy-chained to form long runs.
Traxon Cove Light AC HO RGB Graze Specificationvalorlighting
The Cove Light AC HO RGB Graze is a slim profile, AC line powered
high brightness luminaire. The luminaire is controllable via DMX512 and
perfect for alcove applications. The simplicity of the luminaire’s topology
means it can be simply daisy-chained to form long runs.
NO1 Uk best vashikaran specialist in delhi vashikaran baba near me online vas...Amil Baba Dawood bangali
Contact with Dawood Bhai Just call on +92322-6382012 and we'll help you. We'll solve all your problems within 12 to 24 hours and with 101% guarantee and with astrology systematic. If you want to take any personal or professional advice then also you can call us on +92322-6382012 , ONLINE LOVE PROBLEM & Other all types of Daily Life Problem's.Then CALL or WHATSAPP us on +92322-6382012 and Get all these problems solutions here by Amil Baba DAWOOD BANGALI
#vashikaranspecialist #astrologer #palmistry #amliyaat #taweez #manpasandshadi #horoscope #spiritual #lovelife #lovespell #marriagespell#aamilbabainpakistan #amilbabainkarachi #powerfullblackmagicspell #kalajadumantarspecialist #realamilbaba #AmilbabainPakistan #astrologerincanada #astrologerindubai #lovespellsmaster #kalajaduspecialist #lovespellsthatwork #aamilbabainlahore#blackmagicformarriage #aamilbaba #kalajadu #kalailam #taweez #wazifaexpert #jadumantar #vashikaranspecialist #astrologer #palmistry #amliyaat #taweez #manpasandshadi #horoscope #spiritual #lovelife #lovespell #marriagespell#aamilbabainpakistan #amilbabainkarachi #powerfullblackmagicspell #kalajadumantarspecialist #realamilbaba #AmilbabainPakistan #astrologerincanada #astrologerindubai #lovespellsmaster #kalajaduspecialist #lovespellsthatwork #aamilbabainlahore #blackmagicforlove #blackmagicformarriage #aamilbaba #kalajadu #kalailam #taweez #wazifaexpert #jadumantar #vashikaranspecialist #astrologer #palmistry #amliyaat #taweez #manpasandshadi #horoscope #spiritual #lovelife #lovespell #marriagespell#aamilbabainpakistan #amilbabainkarachi #powerfullblackmagicspell #kalajadumantarspecialist #realamilbaba #AmilbabainPakistan #astrologerincanada #astrologerindubai #lovespellsmaster #kalajaduspecialist #lovespellsthatwork #aamilbabainlahore #Amilbabainuk #amilbabainspain #amilbabaindubai #Amilbabainnorway #amilbabainkrachi #amilbabainlahore #amilbabaingujranwalan #amilbabainislamabad
Student information management system project report ii.pdfKamal Acharya
Our project explains about the student management. This project mainly explains the various actions related to student details. This project shows some ease in adding, editing and deleting the student details. It also provides a less time consuming process for viewing, adding, editing and deleting the marks of the students.
Saudi Arabia stands as a titan in the global energy landscape, renowned for its abundant oil and gas resources. It's the largest exporter of petroleum and holds some of the world's most significant reserves. Let's delve into the top 10 oil and gas projects shaping Saudi Arabia's energy future in 2024.
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdffxintegritypublishin
Advancements in technology unveil a myriad of electrical and electronic breakthroughs geared towards efficiently harnessing limited resources to meet human energy demands. The optimization of hybrid solar PV panels and pumped hydro energy supply systems plays a pivotal role in utilizing natural resources effectively. This initiative not only benefits humanity but also fosters environmental sustainability. The study investigated the design optimization of these hybrid systems, focusing on understanding solar radiation patterns, identifying geographical influences on solar radiation, formulating a mathematical model for system optimization, and determining the optimal configuration of PV panels and pumped hydro storage. Through a comparative analysis approach and eight weeks of data collection, the study addressed key research questions related to solar radiation patterns and optimal system design. The findings highlighted regions with heightened solar radiation levels, showcasing substantial potential for power generation and emphasizing the system's efficiency. Optimizing system design significantly boosted power generation, promoted renewable energy utilization, and enhanced energy storage capacity. The study underscored the benefits of optimizing hybrid solar PV panels and pumped hydro energy supply systems for sustainable energy usage. Optimizing the design of solar PV panels and pumped hydro energy supply systems as examined across diverse climatic conditions in a developing country, not only enhances power generation but also improves the integration of renewable energy sources and boosts energy storage capacities, particularly beneficial for less economically prosperous regions. Additionally, the study provides valuable insights for advancing energy research in economically viable areas. Recommendations included conducting site-specific assessments, utilizing advanced modeling tools, implementing regular maintenance protocols, and enhancing communication among system components.
Water scarcity is the lack of fresh water resources to meet the standard water demand. There are two type of water scarcity. One is physical. The other is economic water scarcity.
Final project report on grocery store management system..pdfKamal Acharya
In today’s fast-changing business environment, it’s extremely important to be able to respond to client needs in the most effective and timely manner. If your customers wish to see your business online and have instant access to your products or services.
Online Grocery Store is an e-commerce website, which retails various grocery products. This project allows viewing various products available enables registered users to purchase desired products instantly using Paytm, UPI payment processor (Instant Pay) and also can place order by using Cash on Delivery (Pay Later) option. This project provides an easy access to Administrators and Managers to view orders placed using Pay Later and Instant Pay options.
In order to develop an e-commerce website, a number of Technologies must be studied and understood. These include multi-tiered architecture, server and client-side scripting techniques, implementation technologies, programming language (such as PHP, HTML, CSS, JavaScript) and MySQL relational databases. This is a project with the objective to develop a basic website where a consumer is provided with a shopping cart website and also to know about the technologies used to develop such a website.
This document will discuss each of the underlying technologies to create and implement an e- commerce website.
Sachpazis:Terzaghi Bearing Capacity Estimation in simple terms with Calculati...Dr.Costas Sachpazis
Terzaghi's soil bearing capacity theory, developed by Karl Terzaghi, is a fundamental principle in geotechnical engineering used to determine the bearing capacity of shallow foundations. This theory provides a method to calculate the ultimate bearing capacity of soil, which is the maximum load per unit area that the soil can support without undergoing shear failure. The Calculation HTML Code included.
Immunizing Image Classifiers Against Localized Adversary Attacksgerogepatton
This paper addresses the vulnerability of deep learning models, particularly convolutional neural networks
(CNN)s, to adversarial attacks and presents a proactive training technique designed to counter them. We
introduce a novel volumization algorithm, which transforms 2D images into 3D volumetric representations.
When combined with 3D convolution and deep curriculum learning optimization (CLO), itsignificantly improves
the immunity of models against localized universal attacks by up to 40%. We evaluate our proposed approach
using contemporary CNN architectures and the modified Canadian Institute for Advanced Research (CIFAR-10
and CIFAR-100) and ImageNet Large Scale Visual Recognition Challenge (ILSVRC12) datasets, showcasing
accuracy improvements over previous techniques. The results indicate that the combination of the volumetric
input and curriculum learning holds significant promise for mitigating adversarial attacks without necessitating
adversary training.
Overview of the fundamental roles in Hydropower generation and the components involved in wider Electrical Engineering.
This paper presents the design and construction of hydroelectric dams from the hydrologist’s survey of the valley before construction, all aspects and involved disciplines, fluid dynamics, structural engineering, generation and mains frequency regulation to the very transmission of power through the network in the United Kingdom.
Author: Robbie Edward Sayers
Collaborators and co editors: Charlie Sims and Connor Healey.
(C) 2024 Robbie E. Sayers
3. 1www.acclaimlighting.com
Contents
Introduction......................................................................2
Welcome 2
Safety 2
Supplied items 3
Optional extras 3
Installation.........................................................................4
Mount adjustment 4
Optional 90O
bracket 5
Fitting the glare shield 6
Fitting an optional louver 7
Power and control wiring 8
DMX channel designations 10
Operation........................................................................ 11
Addressing fixtures 11
DMX personality mode selection 12
Testing emitter output 13
Further information....................................................... 15
Troubleshooting 15
Specifications 16
Limited product warranty 17
4. 2 www.acclaimlighting.com
Introduction
Welcome
Welcome to the Dyna Graze HO Exterior DMX range from Acclaim Lighting. These aluminum
bodied outdoor fixtures are designed specifically to graze surfaces in close proximity.
Available in 1’and 4’lengths these robust units can be connected in series using combined
power and DMX control cables (with IP67-rated connectors) to greatly simplify installation.
In both 1’and 4’lengths, the Dyna Graze HO Exterior DMX range provides four emitter color
options:
•• RGB - Red, green and blue LED emitters,
•• RGBW - Red, green, blue and cool white LED emitters,
•• RGBA - Red, green, blue and amber LED emitters, or
•• DW (Dynamic White) - 2200K, 3500K and 5000K white emitters.
Additionally, to ensure the correct fit with your installation, you have four lens options:
•• 10º x 10º,
•• 10º x 60º,
•• 30º x 60º, or
•• 60º x 60º.
External control is achieved using the industry standard DMX-512A, while initial
configuration (and optional monitoring) is carried out using RDM (Remote Device
Management) as the units have no control panels.
The internal auto-sensing power supply within each unit can accept mains inputs between
100 to 277VAC at 50 or 60Hz. Total power consumption is just 20W per foot.
A range of optional items such as louvers and extender bars are available to adapt the Dyna
Graze HO Exterior DMX to match your installation.
Safety
•• When fixtures are mounted off-ground, ensure that they are securely fitted to an
appropriate mounting surface.
•• Ensure that the power input is supplied from a correctly fused, earthed and
environmentally protected location.
5. 3www.acclaimlighting.com
Supplied items
Optional extras
Dyna Graze HO Exterior DMX
1’or 4’with matching glare
shield plus feed cable (and
two small locking screws)
Feed cable plus end cap
10’(3m) [DGHFC10]
Link cables
1’(30cm) [DGHLC1]
5’(1.5m) [DGHLC5]
10’(3m) [DGHLC10]
End cap [DGHEC]
Louvers
12”(30cm) [DGHLV12]
48”(1.5m) [DGHLV48]
Extender bars
6”(15cm) [DYNAHEB6]
12”(30cm) [DYNAHEB12]
36”(91cm) [DYNAHEB36]
90O
bracket
[DYNAHMF90]
DMX/RDM
tool plus
male 5pin
XLR lead
[XMT350]
6. 4 www.acclaimlighting.com
Installation
When installing each Dyna Graze fixture, ensure that the surface is level and that nothing is
protruding to damage the mounting bracket(s). Suitable mounting surfaces include steel,
aluminum, concrete or wood structures.
Each mount base has two slots measuring 1”x 0.2”(25 x 5mm) and the base has a thickness
of 0.16”(4mm). Select bolts or screws (not supplied) that fit the mount base(s) correctly and
are particularly suited to the mounting surface.
Mount adjustment
The standard mount(s) provided with each Dyna Graze fixture (1’models have one mount, 4’
models have two) allow tilt angles of roughly 30 degrees from vertical to be achieved. Use a
5mm Allen wrench to adjust the tilt angle.
Tilt adjustment
(5mm Allen wrench required)
Slide adjustment
(2mm Allen wrench required)
Ensure that each base is securely fixed to the mounting surface with appropriate screws/
bolts. If necessary, use a 2mm Allen wrench to loosen each mount to allow them to slide
along the length of the fixture to the required position before re-tightening.
7. 5www.acclaimlighting.com
Optional 90O
bracket
The standard mount brackets supplied with each Dyna Graze are able to achieve roughly 30
degrees (from vertical) tilt in either direction. To achieve tilt angles up to 90 degrees, you will
need to replace the standard brackets with optional 90O
brackets.
Standard mount bracket
(0 to ~30 degree angles possible)
Optional 90O
mount bracket
(0 to ~90 degree angles possible)
To fit the optional bracket, remove the tilt adjust bolt (5mm Allen wrench required), remove
the standard bracket and replace with the new part.
8. 6 www.acclaimlighting.com
Fitting the glare shield
Each Dyna Graze fixture is supplied with a glare shield which can be fitted on either side of
the emitter housing to help conceal the emitters from side view.
To insert the glare shield
1 Carefully slide the glare shield into either of the two channels located on either side of the
emitter housing.
Note: You may find that the glare shield is tight and difficult to slide in, particularly on the 4’
models. If so, smear a small quantity of petroleum jelly onto the angled base of the glare shield
to help it slide.
2 When the shield is fully in place, on the underside of the fixture, insert one of the supplied
small locking screws at either end and tighten them to keep the shield firmly in place.
Glare shield
Locking screw
(M3 x 5mm)
9. 7www.acclaimlighting.com
Fitting an optional louver
Optional louvers are available to eliminate side spill in all directions.
To fit an optional louver
1 Carefully slide the louver into the two channels located on either side of the emitter
housing.
Note: You may find that the louver is tight and difficult to slide in, particularly on the 4’ models.
If so, smear a small quantity of petroleum jelly onto the angled lips of the louver to help it slide.
2 When the louver is fully in place, on the underside of the fixture, insert one of the supplied
small locking screws at either end (on opposite sides) and tighten them to keep the
louver firmly in place.
Louver
Locking screw
(M3 x 5mm)
10. 8 www.acclaimlighting.com
Power and control wiring
Power and control are combined within the IP67-rated feed
cables cords. Input and output connectors are FINEcables® M20
(3+5P), with a male input connector located at one end and
female output connector at the other. Connector placements
are such that abutted units can be directly connected without
need for extra cables.
The cable color designations for the optional feed in cable are
as follows:
Power
The power requirements are as follows:
•• Voltage: 100-277VAC 50/60Hz
•• Power: 20W per 1’section (80W for a 4’model)
Control
The control links use three cores for the DMX512 / RDM connections.
FINEcables® M20
(3+5P) male
Making a temporary control link
Each XMT-350 DMX/RDM tool is supplied with a 5-pin male XLR lead that can be used to
make a temporary control input link with the Dyna Graze feed-in cable. Use wire nuts, conn
blocks or Wago® connectors to temporarily join the two cables:
Dyna Graze
feed in
cable
Male XLR
lead
11. 9www.acclaimlighting.com
In-rush currents
Although LED fixtures are low power devices compared to their traditional source
equivalents, their power supplies exhibit a trait known as‘in-rush’when they are first
powered on. This is caused by the various components within the switched mode
power supplies initially topping themselves up with power. The in-rush period lasts only
milliseconds and does not cause any effect when a handful of units are powered on at the
exact same time. However, if many fixtures are linked to the same power input, they will
momentarily pull a current that may greatly exceed their normal operating level. This may
affect over-current trips when power is applied and should be anticipated when planning
the power panel size requirements. The in-rush current values for the Dyna Graze HO
Exterior DMX fixtures are as follows:
•• Dyna Graze HO Exterior DMX 1’: 30A max @ full load
•• Dyna Graze HO Exterior DMX 4’: 40A max @ full load
Maximum number of fixtures
The maximum number of fixtures that can be connected (using Acclaim cable sets) in a
single series run is dependant on the supply voltage, as follows:
240/277VAC supply: 100 feet (30m) of total fixture length
120VAC supply: 50 feet (15m) of total fixture length
Runs can consist of mixtures of 1’and 4’fixtures, as required, providing the total length of
fixtures (and the total length of fixtures plus cable lengths) is not exceeded. See also the
advice on in-rush currents given below.
In damp or wet location installations, ensure that the output connector of the final fixture
has an end cap fitted [DGHEC] to prevent moisture ingress.
240/277VAC supply: 500 feet (152m) of total fixture plus cable length
120VAC supply: 250 feet (76m) of total fixture plus cable length
12. 10 www.acclaimlighting.com
DMX RGB RGBW RGBA Dynamic White
(EXD) (STD) (EXD) (STD) (EXD) (STD) (EXD) (STD)
1 Red Red Red Red Red Red 2200K 2200K
2 Green Green Green Green Green Green 3500K 3500K
3 Blue Blue Blue Blue Blue Blue 5000K 5000K
4 Red CW CW Amber Amber 2200K
5 Green Red Red 3500K
6 Blue Green Green 5000K
7 Red Blue Blue 2200K
8 Green CW Amber 3500K
9 Blue Red Red 5000K
10 Red Green Green 2200K
11 Green Blue Blue 3500K
12 Blue CW Amber 5000K
13 Red Red
14 Green Green
15 Blue Blue
16 CW Amber
DMX channel designations
The various Dyna Graze HO Exterior DMX variants apply their LED emitters to DMX channels
in different ways, as summarized in the table below. The 1’models always operate in
Standard (STD) mode while the 4’models use Extended (EXD) mode by default, but can be
changed to standard (STD) mode using a DMX/RDM tool (see page 12). When a 4’model
operates in standard mode, all four of its emitter sections operate in unison.
The channel allocations above are shown beginning at DMX address 1. When you configure
a fixture with an alternative DMX address, that value will become the first channel in the list
shown above and the other channels will increment from there.
CW = Cool White
13. 11www.acclaimlighting.com
Operation
Addressing fixtures
Dyna Graze HO Exterior DMX fixtures have no external controls and instead rely on RDM
(Remote Device Management) for all configuration via the DMX interface. This allows
multiple devices to be configured either before or after installation.
Various third party DMX/RDM tools are available; Acclaim Lighting particularly recommend
the Swisson XMT-350 for this task.
To address fixtures using the Swisson XMT-350
1 Connect the XMT-350 to the DMX input line of either a single fixture or multiple fixtures in
a pre-arranged daisy chain configuration.
2 Power on the fixture(s) and the XMT-350.
3 On the XMT-350, press the MODE button, then use the arrow buttons to highlight the RDM
function and press the button to select. The XMT-350 will search for RDM devices and
after a short while the XMT-350 will display a list of all located fixtures:
The fixture that is highlighted within the list should begin flashing its emitters to identify
itself.
4 On the XMT-350, press the right arrow button to change to the PATCH tab:
5 If necessary, use the up/down buttons to choose an alternative fixture.
6 Press the button to set the address for the currently highlighted fixture:
7 Use the up/down buttons to set the required DMX address and then press the button
to store it within the fixture.
8 The highlight will automatically move to the next fixture so that you can address it.
Repeat steps 5 to 7 until all fixtures are addressed.
Note: DMX addresses shown in brackets, e.g.
(001), have been temporarily assigned by the
XMT-350, but are not yet stored within the
fixture(s).
14. 12 www.acclaimlighting.com
DMX personality mode selection
Dyna Graze HO Exterior DMX 4’models have two modes of operation:
•• Extended (EXD) mode - The four emitter sections are addressed individually, or
•• Standard (STD) mode - All four emitter sections are addressed collectively.
Note: Dyna Graze HO Exterior DMX 1’ models always operate in standard (STD) mode.
For a summary of how channels are allocated in both modes for all the model variants, see
page 10.
Using an RDM (Remote Device Management) tool, you can quickly change between the
two operation modes. Various third party DMX/RDM tools are available; Acclaim Lighting
particularly recommend the Swisson XMT-350 for this task.
To change personality modes using the Swisson XMT-350
1 Connect the XMT-350 to the DMX input line of either a single fixture or multiple fixtures in
a pre-arranged daisy chain configuration.
2 Power on the fixture(s) and the XMT-350.
3 On the XMT-350, press the MODE button, then use the arrow buttons to highlight the RDM
function and press the button to select. The XMT-350 will search for RDM devices and
after a short while the XMT-350 will display a list of all located fixtures:
The fixture that is highlighted within the list should begin flashing its emitters to identify
itself.
4 If necessary, use the up/down buttons to highlight an alternative fixture.
5 On the XMT-350, press the button to view details for the chosen fixture and then use
the down button to highlight the DMX PERSONALITY entry:
6 Press the button to view the personality options:
7 Use the up/down buttons to highlight the required personality and then press the
button to store it within the fixture.
8 Press the button to return to the previous screen.
15. 13www.acclaimlighting.com
Testing emitter output
After you have addressed each Dyna Graze HO Exterior DMX fixture we recommend that
you also test each one prior to installation. This can be achieved with your RDM (Remote
Device Management) tool. Various third party DMX/RDM tools are available; Acclaim
Lighting particularly recommend the Swisson XMT-350 for this task.
To test emitter output using the Swisson XMT-350
1 Connect the XMT-350 to the DMX input line of either a single fixture or multiple fixtures in
a pre-arranged daisy chain configuration.
2 Power on the fixture(s) and the XMT-350.
3 On the XMT-350, press the MODE button, then use the arrow buttons to highlight the
SEND function and press the button to select.
4 Use the arrow buttons to determine the DMX output:
•• Use the left and right buttons to choose the DMX address,
•• Use the up and down buttons to increase/decrease the level at the chosen address.
Note: If you wish to send DMX values to all addresses simultaneously (rather than cycling
through them individually), when the XMT-350 is showing address 001, press the left button
once to change to ALL CHANNELS. Now when you set the level it will affect all emitters equally.
16. 14 www.acclaimlighting.com
Further information
Troubleshooting
Luminaire doesn’t turn on
•• Check that power is correctly applied to the fixture and that there is no damage to the
power input cord.
•• Use an RDM tool (such as the Swisson XMT-350) to check the settings and internal
temperature of the fixture.
•• Using an RDM tool, check that the DMX address set within the fixture matches that being
output by the controlling source device.
•• Check that the DMX + (hot) and DMX - (cold) lines on the incoming control link have not
been crossed.
17. 15www.acclaimlighting.com
Specifications
Color models RGB, RGBW, RGBA or Dynamic White (2200-5000K)
Beam angle options 10o
x 10o
, 10o
x 60o
, 30o
x 60o
or 60o
Illuminance (lm/ft2
) 693 (RGBW 10o
x 60o
variant @ 100% - 1 foot section)
Lumen maintenance (L70) 150,000 hours (25o
C)
Control DMX (+ RDM configuration) fixtures controlled in 1’or 4’lengths
Ingress protection IP66, wet location
Fixture connectors FINEcables® M20 3+5P IP67 combined power and control
Maximum lengths in series 50’(15m) @ 120VAC or 100’(30m) @ 240/277VAC
Power input 100 - 277VAC, 50/60Hz
Power consumption 20W (1’model), 80W (4’model)
Housing Anodized brushed aluminum with polycarbonate lens
Mounting 30o
swivel mount included, 90o
swivel mount optional
Operating temperature -40o
F to 122o
F (-40o
C to 50o
C)
Weight 3 lbs/1.4Kg (1’model), 12 lbs/5.4Kg (4’model)
Certifications
Release 1.0b
(1’model)
(4’model)
18. 16 www.acclaimlighting.com
Limited product warranty
A. Acclaim Lighting™ hereby warrants, to the original purchaser, Acclaim Lighting™ finished
products to be free of manufacturing defects in material and workmanship for a standard
period of:
•• Fixtures: 5 Years (1,825 days) from the date of purchase.
•• Flex Products: 3 Years (1,095 days) from the date of purchase.
•• Controllers: 2 Years (730 days) from the date of purchase.
It is the owner’s responsibility to establish the date and place of purchase and warranty
terms by acceptable evidence, at the time service is sought.
B. For warranty service, send the product only to the Acclaim factory. All shipping charges
must be pre-paid. If the requested repairs or service (including parts replacement) are
within the terms of this warranty, Acclaim Lighting™ will pay return shipping charges only
to a designated point within the United States. If the entire instrument is sent, it must
be shipped in its original package. No accessories should be shipped with the product.
If any accessories are shipped with the product, Acclaim Lighting™ shall have no liability
whatsoever for loss of or damage to any such accessories, nor for the safe return there of.
Acclaim reserves the right to replace the item with same or similar product at its discretion.
C. This warranty is void if the serial number has been altered or removed; if the product is
modified in any manner which Acclaim concludes, after inspection, affects the reliability of
the product; if the product has been repaired or serviced by anyone other than the Acclaim
Lighting™ factory unless prior written authorization was issued to purchaser by Acclaim
Lighting™; if the product is damaged because not properly maintained as set forth in the
instruction manual.
D. This is not a service contract, and this warranty does not include maintenance, cleaning
or periodic check-up nor do we guarantee as part of this warranty any lumen performance
during period. Parts not covered by this warranty include: fuses, external power supplies,
third party items not manufactures by Acclaim lighting. During the period specified above,
Acclaim Lighting™ will replace defective parts at its expense, and will absorb all expenses
for warranty service and repair labor by reason of defects in material or workmanship. The
sole responsibility of Acclaim Lighting™ under this warranty shall be limited to the repair
of the product, or replacement thereof, including parts, at the sole discretion of Acclaim
Lighting™. At no time will installation or re-installation or products labor or liability costs will
be assumed by Acclaim Lighting. All products covered by this warranty were manufactured
after January 1, 2012, and bear identifying serial number marks to that effect.
E. Acclaim Lighting™ reserves the right to make changes in design and/or improvements
upon its products without any obligation to include these changes in any products
theretofore manufactured No warranty, whether expressed or implied, is given or made
with respect to any accessory supplied with products describe above. Except to the
extent prohibited by applicable law, all implied warranties made by Acclaim Lighting™ in
connection with this product, including warranties of merchantability or fitness, are limited
in duration to the warranty period set forth above. And no warranties, whether expressed or
implied, including warranties of merchantability or fitness, shall apply to this product after
said period has expired.
F. Marine or extreme weather location applications using Acclaim lighting products are
subject to a 2 year limited warranty and Acclaim must be notified prior to delivery of units
for such applications so that preventative treatment can be made to the products to ensure
proper performance and product life with a special marine code coating / sealing process at
an additional cost.
G. The consumer’s and or dealer’s sole remedy shall be such repair or replacement as is
expressly provide above; and under no circumstances shall Acclaim Lighting™ be liable
for any loss or damage, direct or consequential, arising out of the use of, or inability to use,
this product. This warranty is the only written warranty applicable to Acclaim Lighting™
products and supersedes all prior warranties and written descriptions of warranty terms and
conditions heretofore published.