SlideShare a Scribd company logo
1 of 6
Download to read offline
A suggestion of Optimization Process for Water Pipe Networks Design
Mohamed Somaida 1
, Medhat Elzahar 2
and Mahmoud Sharaan 3
1
Professor of hydraulics, Civil Eng. Department, Port-Said University, Egypt
2
Assistant Professor, Civil Eng. Department, Port-Said University, Egypt
3
Teaching Assistant, Civil Eng. Department, Sues Canal University, Egypt
Abstract. The main aim of the present study is to produce a suggestion of optimization process of water
pipe networks design through studying the effect of pipe and pump costs on the optimization process in a
network with a predetermined layout. In the present study, computer simulation and analytical solutions have
been used for the optimum design of pipe diameters of water distribution pipe networks, supplied from a
groundwater source by pumping. The study has revealed that for improving the design diameters, all of the
cost parameters should be included in the process.
Keywords: optimum network, water pipe network, cost parameters.
1. Introduction
A water distribution network is a system of hydraulic elements contains (pipes, reservoirs, pumps, valves
of different types), which are connected together to provide the quantities of water within prescribed
pressures from sources to consumers. In the cost analysis of water–distribution schemes, there may exit
numerous arrangements of pipe sizes within the network. However, the choice of the optimal arrangement
should be based on reasonable economic considerations. The optimization of pipe networks has been studied
and various researchers had proposed the use of mathematical programming techniques in order to identify
the optimal solution for water distribution systems. The optimal solution always means minimum cost of the
network. The diameter corresponding to this minimum cost is known as the economic pipe diameter.
Featherstone et.al.1983, presented a method to get the minimum cost of the network by equating the first
derivative of the total cost equation with zero, [2].
2. Proposed System for the Study
As a proposal of the study, it is suggested for the study to include the same aquifer system and suggested
layout of pipe network studied before in a previous study, [4]. The suggested layout of pipe network is given
as shown in Fig.1. In the previous study, equal and unequal diameters pipe networks were assumed, the
optimized commercial diameters for the initial assumed diameters determined using the same procedure of
Featherstone 1983, (derivative method),and including all cost parameters in the optimization process, as
shown in Table 1.
3. Effect of Pipe Cost in the Optimization Process
The University of Pretoria together with the Water Research Commission has developed the GENETIC
ALGORTIHM NETWORK OPTIMISATION PROGRAM (GAWUP), with which the optimum diameter(s)
of a water distribution network can be determined. THE GANEO program is part of the Genetic Algorithm
Water Utility Programs software package. The GANEO program utilizes genetic algorithms in the
optimization of the water distribution systems (new networks or improvements to existing networks), [9].
This is adding on package to the public domain hydraulic modeling package EPANET. With GANEO a new
68
2011 International Conference on Environment and BioScience
IPCBEE vol.21 (2011) © (2011) IACSIT Press, Singapore
network can be designed or an existing network can be improved by adding parallel pipes between certain
nodes. The GANEO software has been tested against a number of benchmark problems and provided
promising solutions. Therefore; a suggested case study model used for simulation in EPANET software is
entered as a main network file in the GANEO software data, which including suggested layout of pipe
network and lengths of pipes. The program can be downloaded from the Water Research Commission or the
University of Pretoria website, http://www.sinotechcc.co.za/Software/GAWUP/gawup.html, [9].
The diameters obtained from the running GANEO's software for the best solution are shown in Table 1
Fig. 1: Suggested layout of pipe network and setting of pump, elevated tank, main pipes and P.N.W.
Table 1: Diameters of the optimal networks by "Derivative Method", [4] and GANEO's results
Pipe Ref.
No.
Length
(m)
Including all cost parameters Considering pipe cost only
Commercial optimized diameters, (mm) Commercial optimized
diameters, (mm)
N35 P.N.W Sch (3) P.N.W
P2 179 296.6 296.6 296.6
P3 547 296.6 296.6 296.6
P4 281 296.6 296.6 296.6
P5 236.5 211.8 235.4 169.4
P6 254 188.2 211.8 188.2
P7 362.5 188.2 211.8 188.2
P8 363.5 188.2 188.2 150.6
P9 338 188.2 188.2 131.8
P12 257.5 235.4 211.8 150.6
P13 345.5 188.2 150.6 103.6
P14 233.5 150.6 103.6 84.6
P15 235 103.6 103.6 84.6
where: N35 P.N.W and Sch (3) P.N.W refer to the lowest cost networks in the previous study.
For comparison purpose, the results of optimal diameters, global costs and savings using GANEO’s
software for the suggested layout are given in Table 2.
Table2: Comparison of GANEO's software and derivative methods for global costs and cost savings achieved in N35
P.N.W and Sch (3) P.N.W
Cost and Cost saving
Commercial optimized diameters,
(mm) , “Derivative method”
Commercial optimized
diameters, (mm)
“GANEO’s solution”
N35 P.N.W Sch (3) P.N.W
Pipe Cost, (LE) 979,125.4 977,429.2 935,492.6
Global Cost, (LE) 3,521,654.5 3,520,818.5 3,917,420.0
69
Pipe cost Saving % Compared with
N35 P.N.W
Sch (3) P.N.W
-----
-----
------
------
4.5 %
4.46 %
Global cost Saving % Compared with
N35 P.N.W
Sch (3) P.N.W
-----
-----
------
-------
-11.26 %
-11.24 %
Investigation of Table 2 shows that:
z The diameters reached by GANEO’s solution are smaller than those obtained by the derivative
method, since the first depends on pipe cost only, a condition which is verified at reduced diameters.
z GANEO’s solution for both schemes shows nearly pipe cost savings about 4.5 %.
z For global costs, the cost savings are nearly equal but have negative signs. This means that the
global cost according to GANEO’s are much larger than those obtained by the derivative method.
However, the smaller diameters reached by GANEO’s cause increase of operating head of pump,
pumping cost and pump cost.
4. Excluding the Pump Cost
The cost parameters calculated according to the Egyptian local market, and the same formula of the
total cost used before in the previous study, [4].are given as follows:
Total CostP.N.W , CT = Cpi2 + Cp1 + Cp2 + Cwe + Cet + CLm + Ctr + Cin (1)
Pipe cost, Cpi2 = 1423 * L * D2.12
(2)
424
.
0
2
2
2
)
60
*
60
*
24
(
*
*
*
33
.
0
*
*
1423 ⎟
⎟
⎠
⎞
⎜
⎜
⎝
⎛
=
S
Q
L
C i
i
i
Pi
f
, where
2
.
0
2
2
)
60
*
60
*
24
(
*
*
*
33
.
0
⎟
⎟
⎠
⎞
⎜
⎜
⎝
⎛
=
S
Q
D i
i
f
For all pipes,
⎟
⎟
⎠
⎞
⎜
⎜
⎝
⎛
=
=
=
424
.
0
848
.
0
424
.
0
1
2
*
*
*
0579
.
0 ∑ S
Q
L
C i
i
i
m
i
i
Pi
f
(3)
Where:
m: is the number of pipes (m = 12), Qi : is the individually pipe discharge (m3
/day), S: hydraulic gradient
fi : is the friction factor (function of K/D and Reynolds number), where k is the roughness height, [7]
Pumping cost = Cp1 = A1 * Qt* Hd , A1: is unit cost of pumping =2.984 LE/(m3
/day)/ mLift
Pump cost = Cp2 = A2 * Qt * Hd , A2: is unit cost of pump =0.6 LE/(m3
/day)/ mLift
Well cost = Cwe = 160,000 LE
Elevated tank cost = Cet = C * Qt
0.77
, C: is the cost coefficient of elevated tank= 450
Treatment cost = Ctr = C2 * Qt
0.65
, C2: is the cost coefficient of treatment = 520
Inclusive cost = Cin = C3 * Qt
0.54
, C3: is the cost coefficient of inclusive = 3100
Labor and maintenance cost = CLm = C1 * Qt
0.47
, C1: is the cost coefficient of labor and maintenance =
5000
Then, the general formula for the total cost after excluding the pump term is given as following.
( )
S
Q
.
f
.
L
*
0579
.
0
=
C 424
.
0
848
.
0
i
424
.
0
i
i
m
=
i
1
=
i
T ∑ +A1 Qt Hd +160000 + C Qt
0.2
+ C1 Qt
0.47
+ C2 Qt
0.65
+ C3 Qt
0.54
(4)
In the equation (4), the value of operating head Hd can be expressed as:
Hd = Sw + Z + hr + hL1 + hL2 +hfmax
The previous equation can be expressed as follows:
Hd = Sw + Z + hr + hL1 + hL2 +S Lsh
In which S= the hydraulic gradient of the shortest flow line, of length Lsh, leading from the point of
pressure head elevation over the entire network. The basis of the optimization technique is that the optimal
design is obtained by equating hydraulic gradients between adjacent nodes to a hypothetical value S, and
then equation (4) becomes:
70
( )
S
Q
.
.
L
*
0579
.
0
=
C 424
.
0
848
.
0
i
424
.
0
i
i
m
=
i
1
=
i
T ∑
f
+ A1 Qt (Sw + Z + hr + hL1 + hL2 +S Lsh ) +160000 + C Qt
0.77
+ C1 Qt
0.47
+ C2 Qt
0.65
+ C3 Qt
0.54
(5)
Equation (5), now involves two variables, namely S as the independent variable, and CT as the dependent
variable. This equation can be solved in CT for different values of S; the result is shown in Fig.2 which
shows the total cost, CT, has a minimum value where dCT/ d S equals zero. Thus the value of S can be
calculated by equating the first derivative of equation (5) to zero
( ) t
1.424
S
0.848
i
0.424
i
i
12
=
i
1
=
i
Q
*
836.5
*
2.984
=
Q
*
L
*
0.0579
*
0.424 ∑
f
(
( )
) 702
.
0
t
848
.
0
i
424
.
0
i
i
12
=
i
1
=
i
6
-
Q
Q
.
f
.
L
*
10
*
84
.
9
=
S
∑
Fig.2 Variation of global cost function, CT, with hypothetical hydraulic gradient
Results of the optimum diameters (excluding the pump cost)
The diameters obtained after ignoring the pump cost for each of equal and unequal diameters are
shown in the following Table3.
Table 3: Results of the diameters when excluding the pump cost
On comparison basis, the results for optimal diameters and the corresponding global costs for N35 P.N.W
and Sch (3) P.N.W using the derivative method when ignoring pump cost, Table3, are compared with those
obtained including pump cost. Using the same procedure, the results are given in Table 4
Table 4: Comparison of global costs and savings for N35 P.N.W and Sch (3) P.N.W, excluding and including pump cost
by derivative method
Pipe Ref. No.
Commercial optimized
diameters, (mm)
“including pump cost”
Commercial optimized
diameters, (mm)
“Excluding pump cost”
N35 P.N.W Sch (3) P.N.W N35 P.N.W Sch (3) P.N.W
Pipe Cost, (LE) 979,125.4 977,429.2 971,806.93 972,225.15
Global Cost, (LE) 3,521,654.5 3,520,818.5 3,345,400.0 3,346,534.3
Pipe Ref. No.
Length,
(m)
Commercial optimized diameters, (mm)
N35 P.N.W Sch (3)P.N.W
P2 179 296.6 296.6
P3 547 296.6 296.6
P4 281 296.6 296.6
P5 236.5 211.8 235.4
P6 254 188.2 211.8
P7 362.5 169.4 188.2
P8 363.5 188.2 188.2
P9 338 188.2 188.2
P12 257.5 235.4 211.8
P13 345.5 169.4 150.6
P14 233.5 131.8 84.6
P15 235 103.6 103.6
71
Pipe cost Saving %
Compared with same P.N.W
------- ------- 0.75 % 0.535 %
Global cost Saving %
Compared with same P.N.W
------- ------- 5 % 5%
Investigation of Table 4 shows that:
z The reduction in diameters when excluding pump cost is expected and logical, Fig.3
z When excluding the pump cost in the optimization process, the savings in pipe cost are negligible
which means that, the reductions in diameters size are slight for both schemes.
z 3- For global costs, the savings are about 5% for both schemes. The cost saving is found smaller than
the cost savings ranging from 7% to 11% reached without ignoring the pump cost, [4].
Fig.3. Effect of excluding pump cost on pipe diameters
5. Conclusion and Recommendations
5.1. Conclusions
From the present study the following remarks can be concluded:
1- The computer software is a basic step in the solution of pipe networks for discharge and friction head
loss in individual pipes.
2- GANEO’s Software (which runs for pipe cost only), verifies a cost saving in the pipe cost about 4.5% for
N35 P.N.W and Sch (3) P.N.W, this is considered of minor importance.
3- For global costs, GANEO’s solution gives costs much larger than these obtained by the derivative
method. This is attributed to the smaller diameters reached by GANEO’s solution which leads to larger
operating head of pump and increase pumping and pump costs.
4- Although the GANEO’s software leads to minimum diameters (minimum pipe cost) as an easier and
quick method but the result must be treated with caution, since the energy and other costs are neglected.
5- The study assures the possibility of using the derivative method for global cost functions to develop
analytical expression for optimal design of diameters of pipe networks.
6- Excluding pump cost could reduce the global costs, but this process is not recommended.
7- To improve the design diameters, all the cost parameters must be included in the optimization of the
global cost functions to get the most reliable cost solution.
5.2. Recommendations
It is recommended to:
1- Apply the previous methodologies for the design and/or study of more complex pipe networks.
2- Apply the developed equation on actual water distribution systems, and use of more developed computer
software to get optimal solutions with reduced time.
6. Symbols
A1 Unit cost of pumping
A2 Unit cost of pump
72
C Cost coefficient of concrete elevated tank
C1 Cost coefficient of labor and maintenance
C2 Cost coefficient of treatment
C3 Cost coefficient of inclusive
Cet Cost of concrete elevated tank
Cin Inclusive cost
CL Labor and maintenance cost
Cp1 Pumping cost
Cp2 Pump cost
Cpi1 Pipe cost of (main pipe- galvanized iron)
Cpi2 Pipe cost of (pipe network-Poly vinyl chloride-PVC)
D Diameter of pipe
E.T Elevated tank
f Coefficient of friction
hfmax Max head lost by friction in the countered in the pipe network
hL1 Friction and minor losses in the main from the well to the Elevated tank
hL2 Friction and minor losses in the main from the elevated tank to the inlet of pipe network
hr Residual pressure head in the network
Hd Operating pumping head
L Length of the pipe
Li Individually pipe length
Lsh Shortest flow line
P.N.W Pipe network
Qi Individually pipe discharge
Qt Pumping flow rate
S Optimum Hydraulic gradient
Sw Drawdown in the well
T.W Tested well
Z Depth of water table before pumping from the ground level
7. References
[1] Bouwer .H, Groundwater Hydrology, Mcgraw-Hill Inc, 1978
[2] Featherstone, R.E., and El-Jumaily, K.K., "Optimal Diameter Selection for Pipe Networks," Journal of Hydraulic
Engineering, ASCE, Vol. 109, No. 2, 1983, Pp. 221-234.
[3] Http://Ebookbrowse.Com/8-Pipe-Note-2-Pdf-D5233830
[4] Sharaan. M.S 2011, “The Use of Computer Simulation and Analytical Solutions for Optimal Design of Pipe
Networks Supplied from a Pumped Groundwater Source”, A Master Degree Thesis Submitted To Port-Said
University.
[5] Steel .E .W And Mcghee .Terence .J, Water Supply and Sewerage, Mcgraw-Hill International Edition, Series 1988
[6] Suez Canal University, Faculty Of Engineering, (2005): Hydraulic Project, Civil Engineering Department.
[7] Somaida. M. M, Elzahar. M. M. and Sharaan. M.S., "The Use of Computer Simulation and Analytical Solutions for
Optimal Design of Pipe Networks Supplied from a Pumped-Groundwater Source." Accepted to be published in
Port-said journal, August, 2011"
[8] Www.Epa.Gov/ORD/NRMRL/Wswrd/Epanet.Html, (Rossman 1994, Www.Epa.Gov)
[9] Www.sinotechcc.co.za/Software/GAWUP/gawup.html
73

More Related Content

What's hot

Comparison of MOC and Lax FDE for simulating transients in Pipe Flows
Comparison of  MOC and Lax FDE for simulating transients in Pipe FlowsComparison of  MOC and Lax FDE for simulating transients in Pipe Flows
Comparison of MOC and Lax FDE for simulating transients in Pipe FlowsIRJET Journal
 
Thin Film Pressure Estimation of Argon and Water using LAMMPS
Thin Film Pressure Estimation of Argon and Water using LAMMPSThin Film Pressure Estimation of Argon and Water using LAMMPS
Thin Film Pressure Estimation of Argon and Water using LAMMPSCSCJournals
 
13C NMR Derived Average Molecules - Heavy Petroleum - ISMAR 2013
13C NMR Derived Average Molecules - Heavy Petroleum - ISMAR 201313C NMR Derived Average Molecules - Heavy Petroleum - ISMAR 2013
13C NMR Derived Average Molecules - Heavy Petroleum - ISMAR 2013John Edwards
 
The Comprehensive Computation Model of Gas Permeability Based on Fuzzy Comple...
The Comprehensive Computation Model of Gas Permeability Based on Fuzzy Comple...The Comprehensive Computation Model of Gas Permeability Based on Fuzzy Comple...
The Comprehensive Computation Model of Gas Permeability Based on Fuzzy Comple...IJMERJOURNAL
 
On similarity of pressure head and bubble pressure fractal dimensions for cha...
On similarity of pressure head and bubble pressure fractal dimensions for cha...On similarity of pressure head and bubble pressure fractal dimensions for cha...
On similarity of pressure head and bubble pressure fractal dimensions for cha...Khalid Al-Khidir
 
CATSA_Poster_JNvanRensburg_Nov2016
CATSA_Poster_JNvanRensburg_Nov2016CATSA_Poster_JNvanRensburg_Nov2016
CATSA_Poster_JNvanRensburg_Nov2016Jano van Rensburg
 
Numerical study on free-surface flow
Numerical study on free-surface flowNumerical study on free-surface flow
Numerical study on free-surface flowmiguelpgomes07
 
Seismic time fractal dimension for characterizing Shajara Reservoirs of The P...
Seismic time fractal dimension for characterizing Shajara Reservoirs of The P...Seismic time fractal dimension for characterizing Shajara Reservoirs of The P...
Seismic time fractal dimension for characterizing Shajara Reservoirs of The P...Khalid Al-Khidir
 
Flow rate fractal dimension for characterizing shajara reservoirs of the perm...
Flow rate fractal dimension for characterizing shajara reservoirs of the perm...Flow rate fractal dimension for characterizing shajara reservoirs of the perm...
Flow rate fractal dimension for characterizing shajara reservoirs of the perm...Khalid Al-Khidir
 

What's hot (20)

ABSTRACT
ABSTRACTABSTRACT
ABSTRACT
 
03 sp2013
03 sp201303 sp2013
03 sp2013
 
Cavity modes by fem
Cavity modes by femCavity modes by fem
Cavity modes by fem
 
Index
IndexIndex
Index
 
Comparison of MOC and Lax FDE for simulating transients in Pipe Flows
Comparison of  MOC and Lax FDE for simulating transients in Pipe FlowsComparison of  MOC and Lax FDE for simulating transients in Pipe Flows
Comparison of MOC and Lax FDE for simulating transients in Pipe Flows
 
4.pdf
4.pdf4.pdf
4.pdf
 
CCT
CCTCCT
CCT
 
Thin Film Pressure Estimation of Argon and Water using LAMMPS
Thin Film Pressure Estimation of Argon and Water using LAMMPSThin Film Pressure Estimation of Argon and Water using LAMMPS
Thin Film Pressure Estimation of Argon and Water using LAMMPS
 
13C NMR Derived Average Molecules - Heavy Petroleum - ISMAR 2013
13C NMR Derived Average Molecules - Heavy Petroleum - ISMAR 201313C NMR Derived Average Molecules - Heavy Petroleum - ISMAR 2013
13C NMR Derived Average Molecules - Heavy Petroleum - ISMAR 2013
 
The Comprehensive Computation Model of Gas Permeability Based on Fuzzy Comple...
The Comprehensive Computation Model of Gas Permeability Based on Fuzzy Comple...The Comprehensive Computation Model of Gas Permeability Based on Fuzzy Comple...
The Comprehensive Computation Model of Gas Permeability Based on Fuzzy Comple...
 
Packed bed flooding
Packed bed floodingPacked bed flooding
Packed bed flooding
 
Parameters calculation of turbulent fluid flow in a pipe of a circular cross ...
Parameters calculation of turbulent fluid flow in a pipe of a circular cross ...Parameters calculation of turbulent fluid flow in a pipe of a circular cross ...
Parameters calculation of turbulent fluid flow in a pipe of a circular cross ...
 
On similarity of pressure head and bubble pressure fractal dimensions for cha...
On similarity of pressure head and bubble pressure fractal dimensions for cha...On similarity of pressure head and bubble pressure fractal dimensions for cha...
On similarity of pressure head and bubble pressure fractal dimensions for cha...
 
Absorption
AbsorptionAbsorption
Absorption
 
CATSA_Poster_JNvanRensburg_Nov2016
CATSA_Poster_JNvanRensburg_Nov2016CATSA_Poster_JNvanRensburg_Nov2016
CATSA_Poster_JNvanRensburg_Nov2016
 
Numerical study on free-surface flow
Numerical study on free-surface flowNumerical study on free-surface flow
Numerical study on free-surface flow
 
CO2PipeHaz - An Integrated, Multi-scale Modelling Approach for the Simulation...
CO2PipeHaz - An Integrated, Multi-scale Modelling Approach for the Simulation...CO2PipeHaz - An Integrated, Multi-scale Modelling Approach for the Simulation...
CO2PipeHaz - An Integrated, Multi-scale Modelling Approach for the Simulation...
 
Understanding and Predicting CO2 Properties for CCS Transport, Richard Graham...
Understanding and Predicting CO2 Properties for CCS Transport, Richard Graham...Understanding and Predicting CO2 Properties for CCS Transport, Richard Graham...
Understanding and Predicting CO2 Properties for CCS Transport, Richard Graham...
 
Seismic time fractal dimension for characterizing Shajara Reservoirs of The P...
Seismic time fractal dimension for characterizing Shajara Reservoirs of The P...Seismic time fractal dimension for characterizing Shajara Reservoirs of The P...
Seismic time fractal dimension for characterizing Shajara Reservoirs of The P...
 
Flow rate fractal dimension for characterizing shajara reservoirs of the perm...
Flow rate fractal dimension for characterizing shajara reservoirs of the perm...Flow rate fractal dimension for characterizing shajara reservoirs of the perm...
Flow rate fractal dimension for characterizing shajara reservoirs of the perm...
 

Similar to A suggestion of optimization process for water pipe networks design

Cost optimization of pipeline systems using genetic algorithm
Cost optimization of pipeline systems using genetic algorithmCost optimization of pipeline systems using genetic algorithm
Cost optimization of pipeline systems using genetic algorithmIAEME Publication
 
Multi-objective optimization of water distribution system using particle swar...
Multi-objective optimization of water distribution system using particle swar...Multi-objective optimization of water distribution system using particle swar...
Multi-objective optimization of water distribution system using particle swar...iosrjce
 
B041011119
B041011119B041011119
B041011119IOSR-JEN
 
Numerical flow simulation using star ccm+
Numerical flow simulation using star ccm+Numerical flow simulation using star ccm+
Numerical flow simulation using star ccm+Alexander Decker
 
Effect of inertia weight functions of pso in optimization of water distributi...
Effect of inertia weight functions of pso in optimization of water distributi...Effect of inertia weight functions of pso in optimization of water distributi...
Effect of inertia weight functions of pso in optimization of water distributi...IAEME Publication
 
Effect of inertia weight functions of pso in optimization of water distributi...
Effect of inertia weight functions of pso in optimization of water distributi...Effect of inertia weight functions of pso in optimization of water distributi...
Effect of inertia weight functions of pso in optimization of water distributi...IAEME Publication
 
Effect of inertia weight functions of pso in optimization of water distributi...
Effect of inertia weight functions of pso in optimization of water distributi...Effect of inertia weight functions of pso in optimization of water distributi...
Effect of inertia weight functions of pso in optimization of water distributi...IAEME Publication
 
OPTIMIZATION OF COST 231 MODEL FOR 3G WIRELESS COMMUNICATION SIGNAL IN SUBURB...
OPTIMIZATION OF COST 231 MODEL FOR 3G WIRELESS COMMUNICATION SIGNAL IN SUBURB...OPTIMIZATION OF COST 231 MODEL FOR 3G WIRELESS COMMUNICATION SIGNAL IN SUBURB...
OPTIMIZATION OF COST 231 MODEL FOR 3G WIRELESS COMMUNICATION SIGNAL IN SUBURB...Onyebuchi nosiri
 
OPTIMIZATION OF COST 231 MODEL FOR 3G WIRELESS COMMUNICATION SIGNAL IN SUBURB...
OPTIMIZATION OF COST 231 MODEL FOR 3G WIRELESS COMMUNICATION SIGNAL IN SUBURB...OPTIMIZATION OF COST 231 MODEL FOR 3G WIRELESS COMMUNICATION SIGNAL IN SUBURB...
OPTIMIZATION OF COST 231 MODEL FOR 3G WIRELESS COMMUNICATION SIGNAL IN SUBURB...Onyebuchi nosiri
 
Computer aided thermal_design_optimisati
Computer aided thermal_design_optimisatiComputer aided thermal_design_optimisati
Computer aided thermal_design_optimisatissusercf6d0e
 
Model predictive-fuzzy-control-of-air-ratio-for-automotive-engines
Model predictive-fuzzy-control-of-air-ratio-for-automotive-enginesModel predictive-fuzzy-control-of-air-ratio-for-automotive-engines
Model predictive-fuzzy-control-of-air-ratio-for-automotive-enginespace130557
 
Metamodel-based Optimization of a PID Controller Parameters for a Coupled-tan...
Metamodel-based Optimization of a PID Controller Parameters for a Coupled-tan...Metamodel-based Optimization of a PID Controller Parameters for a Coupled-tan...
Metamodel-based Optimization of a PID Controller Parameters for a Coupled-tan...TELKOMNIKA JOURNAL
 
Numerical analysis for two phase flow distribution headers in heat exchangers
Numerical analysis for two phase flow distribution headers in heat exchangersNumerical analysis for two phase flow distribution headers in heat exchangers
Numerical analysis for two phase flow distribution headers in heat exchangerseSAT Journals
 
Design and Analysis of a Full Subtractor using Various Design Techniques
Design and Analysis of a Full Subtractor using Various Design TechniquesDesign and Analysis of a Full Subtractor using Various Design Techniques
Design and Analysis of a Full Subtractor using Various Design TechniquesIRJET Journal
 
Analysis of Material Discharge Rate of Pneumatic Conveying System using Genet...
Analysis of Material Discharge Rate of Pneumatic Conveying System using Genet...Analysis of Material Discharge Rate of Pneumatic Conveying System using Genet...
Analysis of Material Discharge Rate of Pneumatic Conveying System using Genet...Yassin Alkassar
 

Similar to A suggestion of optimization process for water pipe networks design (20)

Cost optimization of pipeline systems using genetic algorithm
Cost optimization of pipeline systems using genetic algorithmCost optimization of pipeline systems using genetic algorithm
Cost optimization of pipeline systems using genetic algorithm
 
Multi-objective optimization of water distribution system using particle swar...
Multi-objective optimization of water distribution system using particle swar...Multi-objective optimization of water distribution system using particle swar...
Multi-objective optimization of water distribution system using particle swar...
 
D012612128
D012612128D012612128
D012612128
 
9511
95119511
9511
 
B041011119
B041011119B041011119
B041011119
 
Numerical flow simulation using star ccm+
Numerical flow simulation using star ccm+Numerical flow simulation using star ccm+
Numerical flow simulation using star ccm+
 
Effect of inertia weight functions of pso in optimization of water distributi...
Effect of inertia weight functions of pso in optimization of water distributi...Effect of inertia weight functions of pso in optimization of water distributi...
Effect of inertia weight functions of pso in optimization of water distributi...
 
Effect of inertia weight functions of pso in optimization of water distributi...
Effect of inertia weight functions of pso in optimization of water distributi...Effect of inertia weight functions of pso in optimization of water distributi...
Effect of inertia weight functions of pso in optimization of water distributi...
 
Effect of inertia weight functions of pso in optimization of water distributi...
Effect of inertia weight functions of pso in optimization of water distributi...Effect of inertia weight functions of pso in optimization of water distributi...
Effect of inertia weight functions of pso in optimization of water distributi...
 
OPTIMIZATION OF COST 231 MODEL FOR 3G WIRELESS COMMUNICATION SIGNAL IN SUBURB...
OPTIMIZATION OF COST 231 MODEL FOR 3G WIRELESS COMMUNICATION SIGNAL IN SUBURB...OPTIMIZATION OF COST 231 MODEL FOR 3G WIRELESS COMMUNICATION SIGNAL IN SUBURB...
OPTIMIZATION OF COST 231 MODEL FOR 3G WIRELESS COMMUNICATION SIGNAL IN SUBURB...
 
OPTIMIZATION OF COST 231 MODEL FOR 3G WIRELESS COMMUNICATION SIGNAL IN SUBURB...
OPTIMIZATION OF COST 231 MODEL FOR 3G WIRELESS COMMUNICATION SIGNAL IN SUBURB...OPTIMIZATION OF COST 231 MODEL FOR 3G WIRELESS COMMUNICATION SIGNAL IN SUBURB...
OPTIMIZATION OF COST 231 MODEL FOR 3G WIRELESS COMMUNICATION SIGNAL IN SUBURB...
 
Computer aided thermal_design_optimisati
Computer aided thermal_design_optimisatiComputer aided thermal_design_optimisati
Computer aided thermal_design_optimisati
 
Model predictive-fuzzy-control-of-air-ratio-for-automotive-engines
Model predictive-fuzzy-control-of-air-ratio-for-automotive-enginesModel predictive-fuzzy-control-of-air-ratio-for-automotive-engines
Model predictive-fuzzy-control-of-air-ratio-for-automotive-engines
 
Metamodel-based Optimization of a PID Controller Parameters for a Coupled-tan...
Metamodel-based Optimization of a PID Controller Parameters for a Coupled-tan...Metamodel-based Optimization of a PID Controller Parameters for a Coupled-tan...
Metamodel-based Optimization of a PID Controller Parameters for a Coupled-tan...
 
Study of the Pipeline Network Planned in the Humber Region of the UK, Xiaobo ...
Study of the Pipeline Network Planned in the Humber Region of the UK, Xiaobo ...Study of the Pipeline Network Planned in the Humber Region of the UK, Xiaobo ...
Study of the Pipeline Network Planned in the Humber Region of the UK, Xiaobo ...
 
05725150
0572515005725150
05725150
 
01 kern's method.
01 kern's method.01 kern's method.
01 kern's method.
 
Numerical analysis for two phase flow distribution headers in heat exchangers
Numerical analysis for two phase flow distribution headers in heat exchangersNumerical analysis for two phase flow distribution headers in heat exchangers
Numerical analysis for two phase flow distribution headers in heat exchangers
 
Design and Analysis of a Full Subtractor using Various Design Techniques
Design and Analysis of a Full Subtractor using Various Design TechniquesDesign and Analysis of a Full Subtractor using Various Design Techniques
Design and Analysis of a Full Subtractor using Various Design Techniques
 
Analysis of Material Discharge Rate of Pneumatic Conveying System using Genet...
Analysis of Material Discharge Rate of Pneumatic Conveying System using Genet...Analysis of Material Discharge Rate of Pneumatic Conveying System using Genet...
Analysis of Material Discharge Rate of Pneumatic Conveying System using Genet...
 

More from Medhat Elzahar

Oily wastewater treatment using polyamide thin film composite membrane
Oily wastewater treatment using polyamide thin film composite membraneOily wastewater treatment using polyamide thin film composite membrane
Oily wastewater treatment using polyamide thin film composite membraneMedhat Elzahar
 
Developed method for treatment of industrial wastewater from edible oil indus...
Developed method for treatment of industrial wastewater from edible oil indus...Developed method for treatment of industrial wastewater from edible oil indus...
Developed method for treatment of industrial wastewater from edible oil indus...Medhat Elzahar
 
The use of computer simulation and analytical solutions for optimal design of...
The use of computer simulation and analytical solutions for optimal design of...The use of computer simulation and analytical solutions for optimal design of...
The use of computer simulation and analytical solutions for optimal design of...Medhat Elzahar
 
Co2 gas flotation of waste activated sludge using weak vacuum pressure with t...
Co2 gas flotation of waste activated sludge using weak vacuum pressure with t...Co2 gas flotation of waste activated sludge using weak vacuum pressure with t...
Co2 gas flotation of waste activated sludge using weak vacuum pressure with t...Medhat Elzahar
 
Basic study of bubble formation in dissolved co2 gas flotation of waste activ...
Basic study of bubble formation in dissolved co2 gas flotation of waste activ...Basic study of bubble formation in dissolved co2 gas flotation of waste activ...
Basic study of bubble formation in dissolved co2 gas flotation of waste activ...Medhat Elzahar
 
Dewatering Waste Activated Sludge Using Greenhouse-Gas Flotation followed by ...
Dewatering Waste Activated Sludge Using Greenhouse-Gas Flotation followed by ...Dewatering Waste Activated Sludge Using Greenhouse-Gas Flotation followed by ...
Dewatering Waste Activated Sludge Using Greenhouse-Gas Flotation followed by ...Medhat Elzahar
 
Experimental studies on flotation of waste activated sludge using carbon diox...
Experimental studies on flotation of waste activated sludge using carbon diox...Experimental studies on flotation of waste activated sludge using carbon diox...
Experimental studies on flotation of waste activated sludge using carbon diox...Medhat Elzahar
 
Study of the Quality of Irrigation Water in South-East El-Kantara Canal, Nort...
Study of the Quality of Irrigation Water in South-East El-Kantara Canal, Nort...Study of the Quality of Irrigation Water in South-East El-Kantara Canal, Nort...
Study of the Quality of Irrigation Water in South-East El-Kantara Canal, Nort...Medhat Elzahar
 

More from Medhat Elzahar (8)

Oily wastewater treatment using polyamide thin film composite membrane
Oily wastewater treatment using polyamide thin film composite membraneOily wastewater treatment using polyamide thin film composite membrane
Oily wastewater treatment using polyamide thin film composite membrane
 
Developed method for treatment of industrial wastewater from edible oil indus...
Developed method for treatment of industrial wastewater from edible oil indus...Developed method for treatment of industrial wastewater from edible oil indus...
Developed method for treatment of industrial wastewater from edible oil indus...
 
The use of computer simulation and analytical solutions for optimal design of...
The use of computer simulation and analytical solutions for optimal design of...The use of computer simulation and analytical solutions for optimal design of...
The use of computer simulation and analytical solutions for optimal design of...
 
Co2 gas flotation of waste activated sludge using weak vacuum pressure with t...
Co2 gas flotation of waste activated sludge using weak vacuum pressure with t...Co2 gas flotation of waste activated sludge using weak vacuum pressure with t...
Co2 gas flotation of waste activated sludge using weak vacuum pressure with t...
 
Basic study of bubble formation in dissolved co2 gas flotation of waste activ...
Basic study of bubble formation in dissolved co2 gas flotation of waste activ...Basic study of bubble formation in dissolved co2 gas flotation of waste activ...
Basic study of bubble formation in dissolved co2 gas flotation of waste activ...
 
Dewatering Waste Activated Sludge Using Greenhouse-Gas Flotation followed by ...
Dewatering Waste Activated Sludge Using Greenhouse-Gas Flotation followed by ...Dewatering Waste Activated Sludge Using Greenhouse-Gas Flotation followed by ...
Dewatering Waste Activated Sludge Using Greenhouse-Gas Flotation followed by ...
 
Experimental studies on flotation of waste activated sludge using carbon diox...
Experimental studies on flotation of waste activated sludge using carbon diox...Experimental studies on flotation of waste activated sludge using carbon diox...
Experimental studies on flotation of waste activated sludge using carbon diox...
 
Study of the Quality of Irrigation Water in South-East El-Kantara Canal, Nort...
Study of the Quality of Irrigation Water in South-East El-Kantara Canal, Nort...Study of the Quality of Irrigation Water in South-East El-Kantara Canal, Nort...
Study of the Quality of Irrigation Water in South-East El-Kantara Canal, Nort...
 

Recently uploaded

(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...
(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...
(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...ranjana rawat
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxJoão Esperancinha
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxupamatechverse
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxpranjaldaimarysona
 
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSMANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSSIVASHANKAR N
 
SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )Tsuyoshi Horigome
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSKurinjimalarL3
 
Extrusion Processes and Their Limitations
Extrusion Processes and Their LimitationsExtrusion Processes and Their Limitations
Extrusion Processes and Their Limitations120cr0395
 
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Serviceranjana rawat
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...Call Girls in Nagpur High Profile
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVRajaP95
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130Suhani Kapoor
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Christo Ananth
 
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝soniya singh
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...Soham Mondal
 

Recently uploaded (20)

(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...
(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...
(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptx
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptx
 
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSMANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
 
SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
 
Extrusion Processes and Their Limitations
Extrusion Processes and Their LimitationsExtrusion Processes and Their Limitations
Extrusion Processes and Their Limitations
 
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
 
Roadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and RoutesRoadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and Routes
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
 
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
 

A suggestion of optimization process for water pipe networks design

  • 1. A suggestion of Optimization Process for Water Pipe Networks Design Mohamed Somaida 1 , Medhat Elzahar 2 and Mahmoud Sharaan 3 1 Professor of hydraulics, Civil Eng. Department, Port-Said University, Egypt 2 Assistant Professor, Civil Eng. Department, Port-Said University, Egypt 3 Teaching Assistant, Civil Eng. Department, Sues Canal University, Egypt Abstract. The main aim of the present study is to produce a suggestion of optimization process of water pipe networks design through studying the effect of pipe and pump costs on the optimization process in a network with a predetermined layout. In the present study, computer simulation and analytical solutions have been used for the optimum design of pipe diameters of water distribution pipe networks, supplied from a groundwater source by pumping. The study has revealed that for improving the design diameters, all of the cost parameters should be included in the process. Keywords: optimum network, water pipe network, cost parameters. 1. Introduction A water distribution network is a system of hydraulic elements contains (pipes, reservoirs, pumps, valves of different types), which are connected together to provide the quantities of water within prescribed pressures from sources to consumers. In the cost analysis of water–distribution schemes, there may exit numerous arrangements of pipe sizes within the network. However, the choice of the optimal arrangement should be based on reasonable economic considerations. The optimization of pipe networks has been studied and various researchers had proposed the use of mathematical programming techniques in order to identify the optimal solution for water distribution systems. The optimal solution always means minimum cost of the network. The diameter corresponding to this minimum cost is known as the economic pipe diameter. Featherstone et.al.1983, presented a method to get the minimum cost of the network by equating the first derivative of the total cost equation with zero, [2]. 2. Proposed System for the Study As a proposal of the study, it is suggested for the study to include the same aquifer system and suggested layout of pipe network studied before in a previous study, [4]. The suggested layout of pipe network is given as shown in Fig.1. In the previous study, equal and unequal diameters pipe networks were assumed, the optimized commercial diameters for the initial assumed diameters determined using the same procedure of Featherstone 1983, (derivative method),and including all cost parameters in the optimization process, as shown in Table 1. 3. Effect of Pipe Cost in the Optimization Process The University of Pretoria together with the Water Research Commission has developed the GENETIC ALGORTIHM NETWORK OPTIMISATION PROGRAM (GAWUP), with which the optimum diameter(s) of a water distribution network can be determined. THE GANEO program is part of the Genetic Algorithm Water Utility Programs software package. The GANEO program utilizes genetic algorithms in the optimization of the water distribution systems (new networks or improvements to existing networks), [9]. This is adding on package to the public domain hydraulic modeling package EPANET. With GANEO a new 68 2011 International Conference on Environment and BioScience IPCBEE vol.21 (2011) © (2011) IACSIT Press, Singapore
  • 2. network can be designed or an existing network can be improved by adding parallel pipes between certain nodes. The GANEO software has been tested against a number of benchmark problems and provided promising solutions. Therefore; a suggested case study model used for simulation in EPANET software is entered as a main network file in the GANEO software data, which including suggested layout of pipe network and lengths of pipes. The program can be downloaded from the Water Research Commission or the University of Pretoria website, http://www.sinotechcc.co.za/Software/GAWUP/gawup.html, [9]. The diameters obtained from the running GANEO's software for the best solution are shown in Table 1 Fig. 1: Suggested layout of pipe network and setting of pump, elevated tank, main pipes and P.N.W. Table 1: Diameters of the optimal networks by "Derivative Method", [4] and GANEO's results Pipe Ref. No. Length (m) Including all cost parameters Considering pipe cost only Commercial optimized diameters, (mm) Commercial optimized diameters, (mm) N35 P.N.W Sch (3) P.N.W P2 179 296.6 296.6 296.6 P3 547 296.6 296.6 296.6 P4 281 296.6 296.6 296.6 P5 236.5 211.8 235.4 169.4 P6 254 188.2 211.8 188.2 P7 362.5 188.2 211.8 188.2 P8 363.5 188.2 188.2 150.6 P9 338 188.2 188.2 131.8 P12 257.5 235.4 211.8 150.6 P13 345.5 188.2 150.6 103.6 P14 233.5 150.6 103.6 84.6 P15 235 103.6 103.6 84.6 where: N35 P.N.W and Sch (3) P.N.W refer to the lowest cost networks in the previous study. For comparison purpose, the results of optimal diameters, global costs and savings using GANEO’s software for the suggested layout are given in Table 2. Table2: Comparison of GANEO's software and derivative methods for global costs and cost savings achieved in N35 P.N.W and Sch (3) P.N.W Cost and Cost saving Commercial optimized diameters, (mm) , “Derivative method” Commercial optimized diameters, (mm) “GANEO’s solution” N35 P.N.W Sch (3) P.N.W Pipe Cost, (LE) 979,125.4 977,429.2 935,492.6 Global Cost, (LE) 3,521,654.5 3,520,818.5 3,917,420.0 69
  • 3. Pipe cost Saving % Compared with N35 P.N.W Sch (3) P.N.W ----- ----- ------ ------ 4.5 % 4.46 % Global cost Saving % Compared with N35 P.N.W Sch (3) P.N.W ----- ----- ------ ------- -11.26 % -11.24 % Investigation of Table 2 shows that: z The diameters reached by GANEO’s solution are smaller than those obtained by the derivative method, since the first depends on pipe cost only, a condition which is verified at reduced diameters. z GANEO’s solution for both schemes shows nearly pipe cost savings about 4.5 %. z For global costs, the cost savings are nearly equal but have negative signs. This means that the global cost according to GANEO’s are much larger than those obtained by the derivative method. However, the smaller diameters reached by GANEO’s cause increase of operating head of pump, pumping cost and pump cost. 4. Excluding the Pump Cost The cost parameters calculated according to the Egyptian local market, and the same formula of the total cost used before in the previous study, [4].are given as follows: Total CostP.N.W , CT = Cpi2 + Cp1 + Cp2 + Cwe + Cet + CLm + Ctr + Cin (1) Pipe cost, Cpi2 = 1423 * L * D2.12 (2) 424 . 0 2 2 2 ) 60 * 60 * 24 ( * * * 33 . 0 * * 1423 ⎟ ⎟ ⎠ ⎞ ⎜ ⎜ ⎝ ⎛ = S Q L C i i i Pi f , where 2 . 0 2 2 ) 60 * 60 * 24 ( * * * 33 . 0 ⎟ ⎟ ⎠ ⎞ ⎜ ⎜ ⎝ ⎛ = S Q D i i f For all pipes, ⎟ ⎟ ⎠ ⎞ ⎜ ⎜ ⎝ ⎛ = = = 424 . 0 848 . 0 424 . 0 1 2 * * * 0579 . 0 ∑ S Q L C i i i m i i Pi f (3) Where: m: is the number of pipes (m = 12), Qi : is the individually pipe discharge (m3 /day), S: hydraulic gradient fi : is the friction factor (function of K/D and Reynolds number), where k is the roughness height, [7] Pumping cost = Cp1 = A1 * Qt* Hd , A1: is unit cost of pumping =2.984 LE/(m3 /day)/ mLift Pump cost = Cp2 = A2 * Qt * Hd , A2: is unit cost of pump =0.6 LE/(m3 /day)/ mLift Well cost = Cwe = 160,000 LE Elevated tank cost = Cet = C * Qt 0.77 , C: is the cost coefficient of elevated tank= 450 Treatment cost = Ctr = C2 * Qt 0.65 , C2: is the cost coefficient of treatment = 520 Inclusive cost = Cin = C3 * Qt 0.54 , C3: is the cost coefficient of inclusive = 3100 Labor and maintenance cost = CLm = C1 * Qt 0.47 , C1: is the cost coefficient of labor and maintenance = 5000 Then, the general formula for the total cost after excluding the pump term is given as following. ( ) S Q . f . L * 0579 . 0 = C 424 . 0 848 . 0 i 424 . 0 i i m = i 1 = i T ∑ +A1 Qt Hd +160000 + C Qt 0.2 + C1 Qt 0.47 + C2 Qt 0.65 + C3 Qt 0.54 (4) In the equation (4), the value of operating head Hd can be expressed as: Hd = Sw + Z + hr + hL1 + hL2 +hfmax The previous equation can be expressed as follows: Hd = Sw + Z + hr + hL1 + hL2 +S Lsh In which S= the hydraulic gradient of the shortest flow line, of length Lsh, leading from the point of pressure head elevation over the entire network. The basis of the optimization technique is that the optimal design is obtained by equating hydraulic gradients between adjacent nodes to a hypothetical value S, and then equation (4) becomes: 70
  • 4. ( ) S Q . . L * 0579 . 0 = C 424 . 0 848 . 0 i 424 . 0 i i m = i 1 = i T ∑ f + A1 Qt (Sw + Z + hr + hL1 + hL2 +S Lsh ) +160000 + C Qt 0.77 + C1 Qt 0.47 + C2 Qt 0.65 + C3 Qt 0.54 (5) Equation (5), now involves two variables, namely S as the independent variable, and CT as the dependent variable. This equation can be solved in CT for different values of S; the result is shown in Fig.2 which shows the total cost, CT, has a minimum value where dCT/ d S equals zero. Thus the value of S can be calculated by equating the first derivative of equation (5) to zero ( ) t 1.424 S 0.848 i 0.424 i i 12 = i 1 = i Q * 836.5 * 2.984 = Q * L * 0.0579 * 0.424 ∑ f ( ( ) ) 702 . 0 t 848 . 0 i 424 . 0 i i 12 = i 1 = i 6 - Q Q . f . L * 10 * 84 . 9 = S ∑ Fig.2 Variation of global cost function, CT, with hypothetical hydraulic gradient Results of the optimum diameters (excluding the pump cost) The diameters obtained after ignoring the pump cost for each of equal and unequal diameters are shown in the following Table3. Table 3: Results of the diameters when excluding the pump cost On comparison basis, the results for optimal diameters and the corresponding global costs for N35 P.N.W and Sch (3) P.N.W using the derivative method when ignoring pump cost, Table3, are compared with those obtained including pump cost. Using the same procedure, the results are given in Table 4 Table 4: Comparison of global costs and savings for N35 P.N.W and Sch (3) P.N.W, excluding and including pump cost by derivative method Pipe Ref. No. Commercial optimized diameters, (mm) “including pump cost” Commercial optimized diameters, (mm) “Excluding pump cost” N35 P.N.W Sch (3) P.N.W N35 P.N.W Sch (3) P.N.W Pipe Cost, (LE) 979,125.4 977,429.2 971,806.93 972,225.15 Global Cost, (LE) 3,521,654.5 3,520,818.5 3,345,400.0 3,346,534.3 Pipe Ref. No. Length, (m) Commercial optimized diameters, (mm) N35 P.N.W Sch (3)P.N.W P2 179 296.6 296.6 P3 547 296.6 296.6 P4 281 296.6 296.6 P5 236.5 211.8 235.4 P6 254 188.2 211.8 P7 362.5 169.4 188.2 P8 363.5 188.2 188.2 P9 338 188.2 188.2 P12 257.5 235.4 211.8 P13 345.5 169.4 150.6 P14 233.5 131.8 84.6 P15 235 103.6 103.6 71
  • 5. Pipe cost Saving % Compared with same P.N.W ------- ------- 0.75 % 0.535 % Global cost Saving % Compared with same P.N.W ------- ------- 5 % 5% Investigation of Table 4 shows that: z The reduction in diameters when excluding pump cost is expected and logical, Fig.3 z When excluding the pump cost in the optimization process, the savings in pipe cost are negligible which means that, the reductions in diameters size are slight for both schemes. z 3- For global costs, the savings are about 5% for both schemes. The cost saving is found smaller than the cost savings ranging from 7% to 11% reached without ignoring the pump cost, [4]. Fig.3. Effect of excluding pump cost on pipe diameters 5. Conclusion and Recommendations 5.1. Conclusions From the present study the following remarks can be concluded: 1- The computer software is a basic step in the solution of pipe networks for discharge and friction head loss in individual pipes. 2- GANEO’s Software (which runs for pipe cost only), verifies a cost saving in the pipe cost about 4.5% for N35 P.N.W and Sch (3) P.N.W, this is considered of minor importance. 3- For global costs, GANEO’s solution gives costs much larger than these obtained by the derivative method. This is attributed to the smaller diameters reached by GANEO’s solution which leads to larger operating head of pump and increase pumping and pump costs. 4- Although the GANEO’s software leads to minimum diameters (minimum pipe cost) as an easier and quick method but the result must be treated with caution, since the energy and other costs are neglected. 5- The study assures the possibility of using the derivative method for global cost functions to develop analytical expression for optimal design of diameters of pipe networks. 6- Excluding pump cost could reduce the global costs, but this process is not recommended. 7- To improve the design diameters, all the cost parameters must be included in the optimization of the global cost functions to get the most reliable cost solution. 5.2. Recommendations It is recommended to: 1- Apply the previous methodologies for the design and/or study of more complex pipe networks. 2- Apply the developed equation on actual water distribution systems, and use of more developed computer software to get optimal solutions with reduced time. 6. Symbols A1 Unit cost of pumping A2 Unit cost of pump 72
  • 6. C Cost coefficient of concrete elevated tank C1 Cost coefficient of labor and maintenance C2 Cost coefficient of treatment C3 Cost coefficient of inclusive Cet Cost of concrete elevated tank Cin Inclusive cost CL Labor and maintenance cost Cp1 Pumping cost Cp2 Pump cost Cpi1 Pipe cost of (main pipe- galvanized iron) Cpi2 Pipe cost of (pipe network-Poly vinyl chloride-PVC) D Diameter of pipe E.T Elevated tank f Coefficient of friction hfmax Max head lost by friction in the countered in the pipe network hL1 Friction and minor losses in the main from the well to the Elevated tank hL2 Friction and minor losses in the main from the elevated tank to the inlet of pipe network hr Residual pressure head in the network Hd Operating pumping head L Length of the pipe Li Individually pipe length Lsh Shortest flow line P.N.W Pipe network Qi Individually pipe discharge Qt Pumping flow rate S Optimum Hydraulic gradient Sw Drawdown in the well T.W Tested well Z Depth of water table before pumping from the ground level 7. References [1] Bouwer .H, Groundwater Hydrology, Mcgraw-Hill Inc, 1978 [2] Featherstone, R.E., and El-Jumaily, K.K., "Optimal Diameter Selection for Pipe Networks," Journal of Hydraulic Engineering, ASCE, Vol. 109, No. 2, 1983, Pp. 221-234. [3] Http://Ebookbrowse.Com/8-Pipe-Note-2-Pdf-D5233830 [4] Sharaan. M.S 2011, “The Use of Computer Simulation and Analytical Solutions for Optimal Design of Pipe Networks Supplied from a Pumped Groundwater Source”, A Master Degree Thesis Submitted To Port-Said University. [5] Steel .E .W And Mcghee .Terence .J, Water Supply and Sewerage, Mcgraw-Hill International Edition, Series 1988 [6] Suez Canal University, Faculty Of Engineering, (2005): Hydraulic Project, Civil Engineering Department. [7] Somaida. M. M, Elzahar. M. M. and Sharaan. M.S., "The Use of Computer Simulation and Analytical Solutions for Optimal Design of Pipe Networks Supplied from a Pumped-Groundwater Source." Accepted to be published in Port-said journal, August, 2011" [8] Www.Epa.Gov/ORD/NRMRL/Wswrd/Epanet.Html, (Rossman 1994, Www.Epa.Gov) [9] Www.sinotechcc.co.za/Software/GAWUP/gawup.html 73