This document provides regulations for the safe use of pump jack scaffolds. It specifies that pump jack scaffolds must have a maximum working load of 500 pounds and a safety factor of at least four times the intended load. Poles cannot exceed 30 feet in height and must be braced securely. No more than two employees can work between supports on a pump jack scaffold at one time. Guardrails or safety belts must also be used. The document includes an employee training record for pump jack scaffolding safety.