6. APPLICATIONS
• Process & produced water disposal
• Tailings & storage dam overloading increasing risk
of catastrophic failure and collapse
• Legacy & mine closure site wastewater issues
• Landfill water management
• Closure of ash basins, dewatering
• Leachate water management
• Uncontrolled release of contaminated mine
water causing environmental harm
• Extreme rainfall events and flooding
9. 1.
2.
3.
4.
Appropriate (Air/Water) 2000:1 Ratio
Water Droplet Particle Size
High-Velocity Air Stream
Large 4mm dia. Orifice Water Fracturing Nozzle Design
FOUR KEY PRINCIPLES
14. EVAPORATION PERFORMANCE MODELLING
• Site Specific
Meteorological
Data Modeling
• Optimum Site Specific
Air to Water and Energy
Ratio Selections
• Chemical and Physical Characteristics
of the Water
• Droplet Evaporation Modeling
17. EVAPORATION
EFFICIENCY
ESTIMATION
Based on 41.5% a single 600/300
evaporator will evaporate…
41.5%
> 56m3 / 249 GPM
> 896m3 / 358,560 GPD
Hour
Day
Year
> 327,040m3 / 130,874,400 GPY
BY THE NUMBERS
21. COMPLETE
ENGINEERED SOLUTION
• Evaporation efficiency modelling
• Water quality analysis and review
• Materials of construction selection
• Plume modelling and analysis
• Designing system requirements to achieve target
evaporation rates
• Design of automation control & operational parameters
• Design & scope of mechanical and electrical requirement
• Construction & Operation
24. TURNKEY SOLUTIONS
ELECTRICAL MCC ON SITE
BANK OF EVAPORATORS OPERATING
PIPEWORK SET UP WEATHER STATION ELECTRICAL CABLE
PUMP ON SITE
25. MINETEK MODEL 600/300 EVAPORATOR
600/300 UNIT, FITTED WITH OPTIONAL
SAFETY PLATFORM AND STAIRWAY
600/300
Water Flow Rate 600 GPM (135m3/hr)
Power 120 HP (90kw)
Pressure 145 PSI (10 Bar)
Mobile skid mounted unit
Galvanised steel, EPOXY coated or 316 Stainless steel
316 Stainless steel wetted parts
Globally patented technology
27. ENVIRONMENTAL MANAGEMENT SYSTEM (EMS)
To maximise the performance of the MINETEK
Evaporators, a control system is available to
autonomously operate the Evaporators under varying
environmental conditions.
The automation systems are designed by MINETEK
and utilize high quality PLC’s, robust Australian made
weather sensors and high quality motor control
components to provide the tools necessary for
autonomous operation.
Automatic shut down due to:
• High humidity
• Rain
• Excess drift (high wind speed)
• Unfavorable wind direction
• Set time periods
28. AUTOMATIC ANGLE ADJUSTER (AAA)
The Automated Hydraulic Angle
Adjuster automatically adjusts the angle
of the Evaporator based on different
wind speeds.
This mechanism works in conjunction
with the EMS and provides flexibility for
the evaporator to operate in a broad
range of weather conditions.
32. Client: Gold mine in Nunavut
System Configuration: 5 x Model 400/200 evaporators,
stainless steel
Automation: Fully automated design
System Capacity: 2000 GPM (450m3/hour) pumped (5 units)
Task: Gold mine tailings dam effluent management solution to
reduce volume or TSF.
Water Quality: Extreme saline water
Seasonal northern climate
CASE STUDY: GOLD MINE IN NUNAVUT
33. Client: Gold mine in Brazil
System Configuration: 2 x Model 400/200 & x
600/300 evaporators, stainless steel
System Capacity: 2000 GPM (450m3/hour)
Task: Gold mine tailings dam effluent
management solution
to reduce volume of TSF.
Features: EPOXY coated evaporators for low
pH water, sound attenuation package.
Urgent delivery
CASE STUDY: GOLD MINE IN BRAZIL
34. Client: Powerplant in Montana
System Configuration: 10 x Model 400/200 evaporators,
stainless steel
Automation: Fully Automated design
System Capacity: 4000 GPM pumped (900m3/hour) pumped
(10 units)
Water Quality: Coal ash pond water, high TDS
CASE STUDY: POWERPLANT IN MONTANA
43. MINEXPO 2021
SEPTEMBER 13TH – 15TH 2021
LAS VEGAS – NEVADA, USA
BOOTH: 3165
NORTH HALL
B.C MINE
SYMPOSIUM
SEPTEMBER 22ND – 23RD 2021
VIRTUAL EVENT
SEE MORE OF MINETEK
44. THANK YOU
• ON DEMAND ACCESS