Eclipse®
Enhanced Model 705
GWR Level Transmitter
for Hygienic Applications
F E A T U R E S
• Two-wire, 24 VDC, loop-powered transmitter for
level, interface, or volume
• HART®
, FOUNDATION fieldbus™
or PROFIBUS PA
digital communications
• Performance not process dependent (changing
specific gravity and dielectric constant have no
significant effect)
• Designed to BPE Standards
• No level change needed for configuration; no
field calibration necessary
• 20-point custom strapping table for volumetric or
flow measurement
• Can measure reliably to very top of vessel and to
the bottom of the probe
• Probes available in 316L SS, AL6XN and
Hastelloy®
C22 (15Ra MAX electropolished probe
rod finish)
• Standard C of C documentation included. (The C of C
includes certification of o-rings, PTFE, and PEEK as
21CFR-177 GRAS and USP <88> Class VI at 121 °C,
and metallic material CMTRs and surface finish
specification.)
• IS, XP, and Non-Incendive approvals
• Two-line, 8-character LCD and 3-button keypad (opt.)
• Quick connect/disconnect probe coupling
• Third Party Safety Integrity Level (SIL) data
(FMEDA analysis) for Safety Instrument Systems
engineering is available. (HART®
version.)
D E S C R I P T I O N
The Enhanced Eclipse®
Model 705 is a loop-powered,
24 VDC, level transmitter based upon the revolutionary
Guided Wave Radar (GWR) technology. This transmitter
offers enhanced reliability, as demonstrated by a
Safe Failure Fraction of 91% (suitable for SIL2
applications).
This ECLIPSE transmitter is designed to provide meas-
urement price/performance well beyond that of all
traditional technologies.
ECLIPSE supports the FDT/DTM standard and a
PACTware™
PC software package allows for additional
configuration and trending flexibility.
T E C H N O L O G Y
ECLIPSE Guided Wave Radar is based upon the tech-
nology of TDR (Time Domain Reflectometry). TDR
utilizes pulses of electromagnetic energy transmitted
down a probe. When a pulse reaches a surface that has
a higher dielectric than the air/vapor in which it is
traveling, the pulse is reflected. Ultra high-speed tim-
ing circuit precisely measures the transit time and pro-
vides an accurate level measurement.
ECLIPSE GWR can be utilized to detect overall level or
interface level, and when used with a HART®
splitter, it
can transmit two 4–20 mA signals.
A P P L I C A T I O N S
MEDIA: Liquids or slurries; hydrocarbons to water-
based media (dielectric 1.9–100).
VESSELS: Most process or storage vessels, up to rated
probe temperature and pressure.
CONDITIONS: Virtually all level measurement and con-
trol applications including process conditions exhibiting
visible vapors, foam, coating/buildup, surface agitation,
bubbling or boiling, high fill/empty rates, low level
and varying dielectric media or specific gravity.
SIL 2
BPE
Miller Energy, Inc. | Exton, PA | 610-363-6200 | www.millerenergy.com
T R A N S M I T T E R S P E C I F I C A T I O N S
Reference conditions Reflection from water at +70 °F (+20 °C) with 72" (1.8 m) single rod probe
in metal vessel (CFD threshold)
Linearity ¿ < 0.1% of probe length or 0.1 inch (3 mm) (whichever is greater)
Measured error ¿ ±0.1% probe length or ±0.1 inch (3 mm) maximum
Resolution ¡ ±0.1 inch (1 mm)
Repeatability ¡ < 0.1 inch (±0.025% of Volume)
Hysteresis ¡ < 0.1 inch (1 mm)
Response time < 1 second
Warm-up time < 5 seconds
operating temperature range -40 to +175 °F (-40 to +80 °C)
LCD readable temperature range -5 to +160 °F (-20 to +70 °C)
operating temperature effect ±0.02% of probe length / °C
Humidity 0-99%, non-condensing
Electromagnetic compatibility Meets CE requirements (EN 61000-6-2/2001, EN 61000-6-4/2001)
(Probes must be used in metallic vessel to maintain CE compliance)
SIL 2 (optional) Safe Failure Fraction (SFF) 91%
P E R F O R M A N C E
F U N C T I O N A L / P H Y S I C A L
2
¿ Specification for top 12 inches of single rod probe will be application dependent.
¡ When used with strapping table
Signal output 4–20 mA with HART, 3.8 to 20.5 mA usable (meets NAMUR NE 43)
FOUNDATION fieldbus™
H1(ITK4.6) (optional)
PROFIBUS PA (optional)
Span 6 inches to 20 feet (15 to 610 cm)
Resolution Analog 0.01 mA
Display 0.1 inches or cm
Loop resistance 630 Ω @ 24 VDC (20.5 mA)
Damping Adjustable 0–10 seconds
Diagnostic alarm Adjustable 3.6 mA, 22 mA, or HOLD
User interface 3-button keypad, HART communicator, FOUNDATION fieldbus™
, PROFIBUS
Display 2-line × 8-character LCD
Power (at terminals)
General purpose/Intrinsically safe 11 to 36 VDC
Explosion proof (with intrinsically safe probe) 11 to 36 VDC
FoUnDAtIon fieldbus/PRoFIBUS PA:
General Purpose/XP 9 to 32 VDC
FoUnDAtIon fieldbus/PRoFIBUS PA:
IS/Fisco 9 to 30 VDC
Menu language English, Spanish, French and German
Housing material 304 stainless steel deep drawn
Aluminum A356T6 (< 0.2% copper) (optional)
net/Gross weight 304 stainless steel 3 lbs (1.36 kg) / 4 lbs (1.81 kg)
Aluminum 6 lbs (2.72 kg) / 7 lbs (3.18 kg)
overall dimensions 304 stainless steel H 4.5" (114mm) x W 3.0" (76mm)
Aluminum H 8.43" (214 mm) x W 4.38" (111 mm) × D 7.40" (188 mm)
3
A G E N C Y A P P R O V A L S
FM 705-5XXX-1XX Intrinsically Safe ¿ Class I, Div. 1; Groups A, B, C, & D
705-5XXX-2XX Class II, Div. 1; Groups E, F, & G T4
Class III, Type 4X, IP66
Entity
705-5XXX-3XX Explosion Proof ¡ Class I, Div. 1; Groups B, C & D
705-5XXX-4XX (with Intrinsically Safe probe) Class II, Div. 1; Groups E, F, & G T4
Class III, Type 4X, IP66
705-5XXX-XXX Non-Incendive Class I, Div. 2; Groups A, B, C, & D
705-5XXX-XXX Suitable for: ¬ Class II, Div. 2; Groups F & G T4
Class III, Type 4X, IP66
CSA 705-5XXX-1XX Intrinsically Safe Class I, Div. 1; Groups A, B, C, & D
705-5XXX-2XX Class II, Div. 1; Group E, F & G T4
Class III, Type 4X
Entity
705-5XXX-3XX Explosion Proof ¡ Class I, Div. 1; Groups B, C & D
705-5XXX-4XX (with Intrinsically Safe probe) Class II, Div. 1; Group E, F & G T4
Class III, Type 4X
705-5XXX-XXX Non-Incendive Class I, Div. 2; Groups A, B, C, & D
705-5XXX-XXX Suitable for: ¬ Class II, Div. 2; Group E, F & G T4
Class III, Type 4X
IEC 705-5XXX-AXX Intrinsically Safe √ Zone 0 Ex ia IIC T4
705-5XXX-BXX
ATEX 705-5XXX-AXX Intrinsically Safe √ II 1G, EEx ia IIC T4
705-5XXX-BXX
705-5XXX-CXX Flame Proof II 1/2G, EEx d [ia] IIC T6
705-5XXX-DXX
705-51XX-EXX Non-sparking II 3(1)G, EEx nA [ia] IIC T4..T6
705-51XX-FXX with probe II 1 G EEx ia IIC T6
705-52XX-EXX II 3(1)G, EEx nA [nL] [ia] IIC T4..T6
705-52XX-FXX with probe II 1 G EEx ia IIC T6
AGENCY MODEL APPROVED APPROVAL CATEGORY APPROVAL CLASSES
¿ Hygienic enclosure is an “end of line” device. Enclosure contains a single conduit entry. Second
conduit entry is plugged and sealed.
¡ Factory Sealed: This product has been approved by Factory Mutual Research (FM), and Canadian
Standards Association (CSA), as a Factory Sealed device.
¬ IMPORTANT: Measured media inside vessel must be non-flammable only.
If media inside vessel is flammable, then the explosion proof version (which
contains an internal barrier making the probe Intrinsically Safe) is required.
√ Special conditions for safe use
Because the enclosure of the Guided Wave Radar Level Transmitter ECLIPSE Model 705-5_ _ _-_1_
and/or Probe ECLIPSE Model 7_ _-_ _ __-_ __ is made of aluminum, if it is mounted in an area
where the use of category 1 G (Zone 0) apparatus is required, it must be installed such, that, even
in the event of rare incidents, ignition sources due to impact and friction sparks are excluded.
For applications in explosive atmospheres caused by gases, vapours or mists and where category
1G (Zone 0) apparatus is required, electrostatic charges on the non-metallic parts of the Probe
ECLIPSE Model 7x5-_ _ __-___, Model 7x7-_ _ __-___ and Model 7_F-_ _ __-___ shall be avoided.
These units are in conformity of:
1. The EMC Directive: 2004/108/EC. The units have
been tested to EN 61326.
2. Directive 94/9/EC for equipment or protective system
for use in potentially explosive atmospheres.
0344
Note: Single and twin rod probes must be used in metallic
vessel or stillwell to maintain CE compliance.
S I N G L E R O D P R O B E S
The pulses of energy from a single rod probe develop between
the center rod and the mounting nut or flange. In other words
the pulse propagates down the rod as it references its ground at
the top of the tank. The efficiency of the pulse “launch” is
directly related to how much metallic surface exists around it at
the top of the vessel.
Figure 1 shows the single element design and how the pulse
expands into a teardrop shape as it propagates away from the
top of the tank (ground reference). Because the design is “open,”
it is the most forgiving of coating and buildup. It is important to
note that a parallel metal wall INCREASES its performance while
a singular, metal object protruding near the probe may be
improperly detected as a liquid level.
P R O B E O V E R V I E W
Figure 1
Single Rod Probe
P A C T W A R E P C S O F T W A R E P R O G R A M
PACTware PC software and the new Field Device Tool (FDT) standard take radar
level measurement to a new level of setup efficiency and user-friendliness. The
powerful ECLIPSE guided wave radar transmitter with its linear program has always
been easy to use. PACTware builds on that ease of use by adding a graphical
software interface. Simply connect your PC through a serial interface to the HART
loop and all functionality can be accessed quickly, conveniently, and safely.
Refer to PACTware bulletins 59-101 and 59-601 for more information.
PACTware offers distinct advantages in loop tuning and configuration
documentation.
4
P R O B E O V E R V I E W ( c o n t . )
N O Z Z L E S
The 7xF and 7xH Single Rod probes may be susceptible to objects
that are in close proximity. The following rules should be followed
for proper application:
1. Nozzle must be 3
⁄4" (19 mm) diameter (A) or larger.
2. Ratio of diameter (A) to length (B) is 1:1 or greater. Any ratio
< 1:1 (e.g., a 2" × 6" nozzle = 1:3) can be used but may
require a BLOCKING DISTANCE and/or SENSITIVITY adjust-
ment. See Figure 2.
3. Pipe reducers that create restriction should not be used. See
Figure 3.
Figure 2
Figure 3
A
B
5
O B S T R U C T I O N S ( M E T A L L I C )
1. If PACTware is used for loop tuning, objects (e.g., shoulders or
agitator blades) can be within 1
⁄4" of probe.
T U R B U L E N C E
The bottom of a single rod probe should be stabilized if turbu-
lence will cause a deflection of more than 3 inches (80 mm) at
10 feet (3 m) of length. A metallic capture ring can be employed
at the bottom of the probe to eliminate torque buildup.
Distance to probe Acceptable objects
< 0.5" (13 mm)
Continuous, smooth, parallel,
conductive surface (e.g., tank
wall); probe should not touch
tank wall
Obstructions (Metallic) – Guidelines
Figure 4
P R O C E S S S E A L T E M P E R A T U R E / P R E S S U R E C H A R T
0
100
200
50 100 300200
ProcessPressure(psig)
Process Temperature (°F) (max. 300)
7XF/7XH
Note: Tri-clamp connection service rating may further limit pressure.
0
6.9
13.8
10 38 15093
ProcessPressure(bar)
Process Temperature (°C) (max. 150)
7XF/7XH
P R O B E & H O U S I N G F E A T U R E S
Stainless Steel Housing with Model 7xH Hygienic probe
ECLIPSE Model 705 transmitter in a 304 SS housing for use in a variety of hygienic applications.
0.5-inch diameter 316L SS probe with a 15Ra MAX surface finish is available with lengths up to 244"
and with Tri-Clover®
type connection sizes from 1" through 4".
In addition, a 0.25-inch diameter 316L SS probe with 15Ra MAX surface finish is available with
lengths up to 72" and with a 3
⁄4" Tri-Clover®
type connection.
11
⁄2" Hygienic Connection with bend
316L SS probes can be bent to avoid internal obstruc-
tions such as agitator blades and spray balls, and to
ensure lowest possible level detection.
3
⁄4" Hygienic Connection without bend
0.25-inch diameter probes suitable for use in smaller
vessels where space is at a premium. Available in
lengths up to 72 inches.
Aluminum Dual Compartment Housing
ECLIPSE Model 705 transmitter is available with an
industrial dual compartment aluminum housing.
6
Segmented Hygienic Probe
Segmented probes are available should the probe be
inserted or removed with limited headroom above the
vessel (segmented lengths are specified by the cus-
tomer). Contact the factory for details.
R E M O T E A S S E M B L Y
The Local/Remote assembly is meant to be a simple and cost-effective way to remove the transmitter electronics
and locate it a short distance away from the probe. The assembly allows a remote distance of 33" (84 cm) or 144"
(3650 cm) which offers a greater degree of flexibility during installation. It is supplied with a remote bracket and
flexible armor conduit as a complete assembly. This can be employed with both styles of housings.
7
33.00 or 144.00
(838 or 3650)
3.75
(95)
3.00
(76)
2.75
(70)
2.00
(51)
3.50
(89)
2 Holes
.38 (10) Dia.
3.08
(78)
2.12
(54)
Elect.
Conn.
Qty. 2
43°
2.53
(64)
4.00
(100)
ECLIPSE Hygienic Remote Configuration
4.28
(109)
4.43
(113)
45° View
ECLIPSE Hygienic Housing
(45° View)
I N C H E S ( M M )
D I M E N S I O N A L S P E C I F I C A T I O N S
I N C H E S ( M M ) — S I N G L E R O D P R O B E S
ECLIPSE Hygienic Housing
(shown with 7xF-E Hygienic Probe)
Probe
Insertion
Length
8.94
(227)
7xF-E:
9.25
(235)
7xH:
Process
Connection
Electrical
Connection
Ø 0.50" (12) Rod
2.53
(64)
2.17
(55)
3.02
(77)
S I N G L E R O D P R O B E M A T R I X
7xF-E, -F, -G and 7xH Hygienic
8
¿ Contact factory for applications requiring probe lengths less than 24" (60 cm).
¡ Refer to Process Temperature vs. Process Pressure Graph
¬ εr 1.9–10 must be mounted between 2–6" (50–150 mm) of metal tank wall.
BPE
Recommended For Applications demanding hygienic specifications
Not Recommended For Low dielectric media (εr < 1.9)
Materials/Wetted
Metallic Parts 7EF: 316L SS, <15 Ra electropolished finish
(Optional: Hastelloy C, AL6XN SS)
7EH: 316L SS, <15 Ra electropolished finish
(Optional: Hastelloy C, AL6XN SS)
Elastomer and
Polymeric Wetted Parts
7EF: PTFE (GRAS 21CFR177-1550 and USP <88> Class VI at 121 °C)
7EH: PEEK and O-ring (Viton or EPDM) (GRAS 21CFR177 and USP <88> Class VI at 121 °C)
Diameter ∅.50 (13 mm) rod for process connections > 3
⁄4" (24–240 inches)
∅ .25 (7 mm) for process connections = 3
⁄4" (24–72 inches)
Flange ANSI (DIN) 3
⁄4 to 4" (38 to 100 cm); Tri-Clamp®
fitting
Length ¿ 24 to 240" (60 to 610 cm) for Tri-Clamp process connections
equal to 1" or greater
24 to 72" (61 to 183 cm) for 3
⁄4" Tri-Clamp type process connection
Transition Zone
Top
Bottom
1" (25 mm) @ εr > 10
1" (25 mm) @ εr > 10
Blocking Distance
Top 0–36" (0–91cm)
probe length/application dependent
Process Temperature ¡
(Max.)
Min. (Cryogenic)
+300 °F @ 200 psig (+150 °C @ 13.8 bar)
Consult factory
Process Pressure Max.
Min. (Vacuum Service)
200 psig @ +300 °F (13.8 bar @ +150 °C) or limit of tri-clamp service rating, whichever
is lower
N/A
Dielectric ¬ 1.9 to 100
Max. Viscosity (cP) 10,000 (consult factory if severe agitation/turbulence)
Mounting Effects See Nozzles and Obstructions on page 5
Coating/Buildup Yes; maximum error 10% of coated length; % of coated length; % error related to dielectric of
media, thickness of coating & coated probe length above media
Foam Yes
Corrosives Yes
Hygienic Yes
Overfill No
Approvals
FM
CSA
ATEX
OTHER
Yes
Yes
Yes
No
T Y P I C A L H Y G I E N I C A P P L I C A T I O N S
The Model 705 transmitters are presently installed in a variety of media systems including bioreactors, fermentors,
media storage, crystallizers, decanters, ultra filtration skid receivers, cook kettles, CIP systems, balance tanks,
mixing tanks, storage tanks, etc.
25K Liter Reactor Tulip Tank1500K Liter Fermentor
or Mix Tank
Utility systems including:
• ammonia storage
• CO2 storage
• inlet water
• deaerator systems
• condensate receivers
• boiler drums
• fuel oil storage
• various sumps
• waste tanks
• neutralization tanks
• kill vessels
Buffer systems, Media Systems
and Filtration including:
• primary mix tanks
• hold tanks
• day tanks
• bulk tanks
CIP systems including:
• wash and rinse tanks
• bulk tanks
• skid delivery tanks
9
0 None – SIL 1 Standard Electronics (SFF=84.5%)
A SIL 2 (Certified) Enhanced Electronics (SFF=91%) ¿
0 3
⁄4" NPT
1 M20
4 1
⁄2" NPT ¬
1 Cast aluminum, dual compartment, 45° angle
2 316L stainless steel, dual compartment, 45° angle
3 304 stainless steel, single compartment ¡
7 Cast aluminum, dual compartment, 12-foot remote
8 316L stainless steel, dual compartment, 12-foot remote
9 304 stainless steel, single compartment, 12-foot remote ¡
0 Digital display and keypad with blind cover
A Digital display and keypad with window cover
M O D E L N U M B E R
T R A N S M I T T E R
10
SIGNAL OUTPUT
7 0 5 5
5 24 VDC, Two-wire
BASIC MODEL NUMBER
POWER
ACCESSORIES
CONDUIT CONNECTION
MOUNTING/CLASSIFICATION
OPTIONS
HOUSING
Models available for quick shipment, usually within one week after factory
receipt of a complete purchase order, through the Expedite Ship Plan (ESP).
705 ECLIPSE Guided Wave Radar Level Transmitter
1
Integral, General Purpose & Intrinsically Safe
(FM & CSA), Non-incendive (Class I, Div. 2)
2
3-foot Remote, General Purpose & Intrinsically Safe
(FM & CSA), Non-incendive (Class I, Div. 2)
3 Integral, Explosion Proof (FM & CSA) & Non-incendive
4 3-foot Remote, Explosion Proof (FM & CSA) & Non-incendive
A
Integral, General Purpose & Intrinsically Safe
(ATEX & JIS EEx ia IIC T4)
B
3-foot Remote, General Purpose & Intrinsically Safe
(ATEX & JIS EEx ia IIC T4)
C
Integral, Explosion Proof (ATEX EEx d [ia] IIC T6)
(must be ordered with Conduit Connection Codes 0 and 1)
D
3-foot Remote, Explosion Proof (ATEX EEx d [ia] IIB T6)
(must be ordered with Conduit Connection Codes 0 and 1)
E Integral, Non-incendive (ATEX EEx n II T4..6)
F 3-foot Remote, Non-incendive (ATEX EEx n II T4..6)
1 4–20 mA with HART
2 FOUNDATION fieldbus™
Digital Communication (English only)
3 PROFIBUS PA Digital Communication (English Only)
¿ Not available with Model 7xH Probe
¡ Not available with conduit connection code 0
¬ Not available with explosion proof Mounting/Classification
codes 3, 4, C, D.
MATERIAL OF CONSTRUCTION
7E ECLIPSE GWR probe, English unit of measure
7M ECLIPSE GWR probe, Metric unit of measure
7 P
BASIC MODEL NUMBER
M O D E L N U M B E R
P R O B E
O-RINGS
11
CONFIGURATION/STYLE
E Hygienic, 316L stainless steel (15 Ra EP finish)
G Hygienic, AL6XN stainless steel (15 Ra EP finish)
H Hygienic, Hastelloy C22 (15 Ra EP finish)
2P 3
⁄4" Tri-Clover®
type, 16 AMP Hygienic Flange (only available with 3rd digit F)
3P 1" or 11
⁄2" Tri-Clover®
type, 16 AMP Hygienic Flange
4P 2" Tri-Clover®
type, 16 AMP Hygienic Flange
5P 3" Tri-Clover®
type, 16 AMP Hygienic Flange
6P 4" Tri-Clover®
type, 16 AMP Hygienic Flange
9P 21
⁄2" Tri-Clover®
type, 16 AMP Hygienic Flange
HYGIENIC FLANGE CONNECTIONS
PROCESS CONNECTION SIZE/TYPE
24 to 240 inches (60 to 610 cm) ¿
(unit of measure is determined by second digit of Model Number)
Examples: 24 inches = 024; 60 centimeters = 060
LENGTH
Insertion Length
Hygienic Flange
¿ Contact factory for applications requiring probe
lengths less than 24" (60 cm).
F Hygienic Single Rod (with PTFE seal)
H Hygienic Single Rod (with O-Ring seal)
1 EPDM (only available with 3rd digit H)
C Viton®
GF (only available with 3rd digit H)
N None (only available with 3rd digit F)
The quality assurance system in place at
Magnetrol®
guarantees the highest level
of quality throughout the company.
MAGNETROL is committed to providing
full customer satisfaction both in quality
products and quality service.
The MAGNETROL quality assurance system
is registered to ISO 9001 affirming its com-
mitment to known international quality
standards providing the strongest assurance
of product/service quality available.
Several Models of ECLIPSE Guided Wave
Radar Transmitters are available for quick
shipment, usually within one week after
factory receipt of a complete purchase
order, through the Expedite Ship Plan (ESP).
Models covered by ESP service are color
coded in the selection data charts.
To take advantage of ESP, simply match the
color coded model number codes (standard
dimensions apply).
ESP service may not apply to orders of ten
units or more. Contact your local representa-
tive for lead times on larger volume orders,
as well as other products and options.
Expedite
Ship
Plan
All MAGNETROL electronic level and flow
controls are warranted free of defects in
materials or workmanship for eighteen
months from the date of original factory
shipment.
If returned within the warranty period; and,
upon factory inspection of the control, the
cause of the claim is determined to be cov-
ered under the warranty; then, MAGNETROL
will repair or replace the control at no cost
to the purchaser (or owner) other than
transportation.
MAGNETROL shall not be liable for misap-
plication, labor claims, direct or consequen-
tial damage or expense arising from the
installation or use of equipment. There are
no other warranties expressed or implied,
except special written warranties covering
some MAGNETROL products.
BULLETIN: 57-110.11
EFFECTIVE: March 2017
SUPERSEDES: July 2016
705 Enterprise Street • Aurora, Illinois 60504-8149 • 630-969-4000 • Fax 630-969-9489
info@magnetrol.com • www.magnetrol.com
Copyright © 2017 Magnetrol International, Incorporated.
Performance specifications are effective with date of issue and are subject to change without notice.
For additional information, see Instruction Manual 57-600.
ECLIPSE Guided Wave Radar transmitters may be protected by one or more of the following U.S. Patent Nos. US 6,062,095: US 6,247,362;
US 6,588,272; US 6,626,038; US 6,640,629; US 6,642,807; US 6,690,320; US 6,750,808; US 6,801,157. May depend on model.
Q U A L I T Y
E S P
W A R R A N T Y
Magnetrol, Magnetrol logotype and Eclipse are registered trademarks of Magnetrol International, Incorporated.
HART®
is a registered trademark of the HART Communication Foundation.
Hastelloy®
is a registered trademark of Haynes International.
Monel®
is a registered trademark of the INCO family of companies.
PEEK™ is a trademark of Vitrex plc.
Teflon®
is a registered trademark of DuPont.
Tri-Clamp is a registered trademark of Ladish Co.
Tri-Clover®
is a registered trademark of Tri-Clover, Inc.
Viton®
and Kalrez®
are registered trademarks of DuPont Performance Elastomers.

More Related Content

What's hot (20)

I&C Technical Note
I&C Technical NoteI&C Technical Note
I&C Technical Note
 
Technical interview-questions
Technical interview-questionsTechnical interview-questions
Technical interview-questions
 
Pressure measurement
Pressure measurement Pressure measurement
Pressure measurement
 
Flow measurement
Flow measurementFlow measurement
Flow measurement
 
Flowmeter course
Flowmeter courseFlowmeter course
Flowmeter course
 
107 basic instrumentation
107 basic instrumentation 107 basic instrumentation
107 basic instrumentation
 
Ch. no. 4 flow measurement
Ch. no. 4 flow measurementCh. no. 4 flow measurement
Ch. no. 4 flow measurement
 
Actuator and valves
Actuator and valvesActuator and valves
Actuator and valves
 
Asr flow measurement
Asr  flow measurementAsr  flow measurement
Asr flow measurement
 
Basic flow measurement
Basic flow measurementBasic flow measurement
Basic flow measurement
 
Level Measurement
Level MeasurementLevel Measurement
Level Measurement
 
Overview of Pressure Relief Valve
Overview of Pressure Relief ValveOverview of Pressure Relief Valve
Overview of Pressure Relief Valve
 
Pressure Measurement
Pressure MeasurementPressure Measurement
Pressure Measurement
 
Control System Components
Control System ComponentsControl System Components
Control System Components
 
Flow measurement part IV
Flow measurement   part IVFlow measurement   part IV
Flow measurement part IV
 
Flowmeter - Brief
Flowmeter   - BriefFlowmeter   - Brief
Flowmeter - Brief
 
Overview of control valves
Overview of control valvesOverview of control valves
Overview of control valves
 
ELASTIC PRESSURE MEASUREMENT DEVICES
ELASTIC PRESSURE MEASUREMENT DEVICESELASTIC PRESSURE MEASUREMENT DEVICES
ELASTIC PRESSURE MEASUREMENT DEVICES
 
Level measurement ppt
Level measurement pptLevel measurement ppt
Level measurement ppt
 
Level measurement
Level measurementLevel measurement
Level measurement
 

Similar to Magnetrol Guide Wave Radar Level Transmitter For Hygienic Applications

Drager Polytron 8310 Fixed Gas Detector - Spec Sheet
Drager Polytron 8310 Fixed Gas Detector - Spec SheetDrager Polytron 8310 Fixed Gas Detector - Spec Sheet
Drager Polytron 8310 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Drager Polytron 5700 Fixed Gas Detector - Spec Sheet
Drager Polytron 5700 Fixed Gas Detector - Spec SheetDrager Polytron 5700 Fixed Gas Detector - Spec Sheet
Drager Polytron 5700 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Drager Polytron 5000 Fixed Gas Detector - Spec Sheet
Drager Polytron 5000 Fixed Gas Detector - Spec SheetDrager Polytron 5000 Fixed Gas Detector - Spec Sheet
Drager Polytron 5000 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
United Electric TX200 Pressure Transmitter
United Electric TX200 Pressure TransmitterUnited Electric TX200 Pressure Transmitter
United Electric TX200 Pressure TransmitterIves Equipment
 
Drager Polytron 5720 Fixed Gas Detector - Spec Sheet
Drager Polytron 5720 Fixed Gas Detector - Spec SheetDrager Polytron 5720 Fixed Gas Detector - Spec Sheet
Drager Polytron 5720 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Drager Polytron 5310 Fixed Gas Detector - Spec Sheet
Drager Polytron 5310 Fixed Gas Detector - Spec SheetDrager Polytron 5310 Fixed Gas Detector - Spec Sheet
Drager Polytron 5310 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Drager Polytron 8720 Fixed Gas Detector - Spec Sheet
Drager Polytron 8720 Fixed Gas Detector - Spec SheetDrager Polytron 8720 Fixed Gas Detector - Spec Sheet
Drager Polytron 8720 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
EasyTREK / EchoTREK Ultrasonic Level Transmitters for Liquids
EasyTREK / EchoTREK Ultrasonic Level Transmitters for LiquidsEasyTREK / EchoTREK Ultrasonic Level Transmitters for Liquids
EasyTREK / EchoTREK Ultrasonic Level Transmitters for LiquidsArjay Automation
 
Pulse Burst Radar Level Transmitters
Pulse Burst Radar Level TransmittersPulse Burst Radar Level Transmitters
Pulse Burst Radar Level TransmittersArjay Automation
 
Drager Polytron 2 XP Tox Fixed Gas Detector - Spec Sheet
Drager Polytron 2 XP Tox Fixed Gas Detector - Spec SheetDrager Polytron 2 XP Tox Fixed Gas Detector - Spec Sheet
Drager Polytron 2 XP Tox Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Drager polytron 2 xp tox fixed gas detector - spec sheet
Drager polytron 2 xp tox   fixed gas detector  - spec sheetDrager polytron 2 xp tox   fixed gas detector  - spec sheet
Drager polytron 2 xp tox fixed gas detector - spec sheetThorne & Derrick UK
 
Megger DET4T2 Series 4-Terminal Earth/Ground Resistance Testers & Soil Resist...
Megger DET4T2 Series 4-Terminal Earth/Ground Resistance Testers & Soil Resist...Megger DET4T2 Series 4-Terminal Earth/Ground Resistance Testers & Soil Resist...
Megger DET4T2 Series 4-Terminal Earth/Ground Resistance Testers & Soil Resist...Angus Sankaran
 
Drager Polytron Pulsar Fixed Gas Detectors - Spec Sheet
Drager Polytron Pulsar Fixed Gas Detectors - Spec SheetDrager Polytron Pulsar Fixed Gas Detectors - Spec Sheet
Drager Polytron Pulsar Fixed Gas Detectors - Spec SheetThorne & Derrick UK
 
Drager Polytron IR Fixed Gas Detector - Spec Sheet
Drager Polytron IR Fixed Gas Detector  - Spec SheetDrager Polytron IR Fixed Gas Detector  - Spec Sheet
Drager Polytron IR Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Dräger Polytron 8700 Fixed Gas Detector - Spec Sheet
Dräger Polytron 8700 Fixed Gas Detector - Spec SheetDräger Polytron 8700 Fixed Gas Detector - Spec Sheet
Dräger Polytron 8700 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Drager Polytron 8200 Fixed Gas Detector - Spec Sheet
Drager Polytron 8200 Fixed Gas Detector - Spec SheetDrager Polytron 8200 Fixed Gas Detector - Spec Sheet
Drager Polytron 8200 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 

Similar to Magnetrol Guide Wave Radar Level Transmitter For Hygienic Applications (20)

Drager Polytron 8310 Fixed Gas Detector - Spec Sheet
Drager Polytron 8310 Fixed Gas Detector - Spec SheetDrager Polytron 8310 Fixed Gas Detector - Spec Sheet
Drager Polytron 8310 Fixed Gas Detector - Spec Sheet
 
Drager Polytron 5700 Fixed Gas Detector - Spec Sheet
Drager Polytron 5700 Fixed Gas Detector - Spec SheetDrager Polytron 5700 Fixed Gas Detector - Spec Sheet
Drager Polytron 5700 Fixed Gas Detector - Spec Sheet
 
Drager Polytron 5000 Fixed Gas Detector - Spec Sheet
Drager Polytron 5000 Fixed Gas Detector - Spec SheetDrager Polytron 5000 Fixed Gas Detector - Spec Sheet
Drager Polytron 5000 Fixed Gas Detector - Spec Sheet
 
United Electric TX200 Pressure Transmitter
United Electric TX200 Pressure TransmitterUnited Electric TX200 Pressure Transmitter
United Electric TX200 Pressure Transmitter
 
Drager Polytron 5720 Fixed Gas Detector - Spec Sheet
Drager Polytron 5720 Fixed Gas Detector - Spec SheetDrager Polytron 5720 Fixed Gas Detector - Spec Sheet
Drager Polytron 5720 Fixed Gas Detector - Spec Sheet
 
Drager Polytron 5310 Fixed Gas Detector - Spec Sheet
Drager Polytron 5310 Fixed Gas Detector - Spec SheetDrager Polytron 5310 Fixed Gas Detector - Spec Sheet
Drager Polytron 5310 Fixed Gas Detector - Spec Sheet
 
Brooks Ar-Mite Low Flow Armored Flowmeter
Brooks Ar-Mite Low Flow Armored FlowmeterBrooks Ar-Mite Low Flow Armored Flowmeter
Brooks Ar-Mite Low Flow Armored Flowmeter
 
Drager Polytron 8720 Fixed Gas Detector - Spec Sheet
Drager Polytron 8720 Fixed Gas Detector - Spec SheetDrager Polytron 8720 Fixed Gas Detector - Spec Sheet
Drager Polytron 8720 Fixed Gas Detector - Spec Sheet
 
Radar Non-Contact Level Transmitter
Radar Non-Contact Level TransmitterRadar Non-Contact Level Transmitter
Radar Non-Contact Level Transmitter
 
EasyTREK / EchoTREK Ultrasonic Level Transmitters for Liquids
EasyTREK / EchoTREK Ultrasonic Level Transmitters for LiquidsEasyTREK / EchoTREK Ultrasonic Level Transmitters for Liquids
EasyTREK / EchoTREK Ultrasonic Level Transmitters for Liquids
 
Pulse Burst Radar Level Transmitters
Pulse Burst Radar Level TransmittersPulse Burst Radar Level Transmitters
Pulse Burst Radar Level Transmitters
 
Drager Polytron 2 XP Tox Fixed Gas Detector - Spec Sheet
Drager Polytron 2 XP Tox Fixed Gas Detector - Spec SheetDrager Polytron 2 XP Tox Fixed Gas Detector - Spec Sheet
Drager Polytron 2 XP Tox Fixed Gas Detector - Spec Sheet
 
Drager polytron 2 xp tox fixed gas detector - spec sheet
Drager polytron 2 xp tox   fixed gas detector  - spec sheetDrager polytron 2 xp tox   fixed gas detector  - spec sheet
Drager polytron 2 xp tox fixed gas detector - spec sheet
 
Megger DET4T2 Series 4-Terminal Earth/Ground Resistance Testers & Soil Resist...
Megger DET4T2 Series 4-Terminal Earth/Ground Resistance Testers & Soil Resist...Megger DET4T2 Series 4-Terminal Earth/Ground Resistance Testers & Soil Resist...
Megger DET4T2 Series 4-Terminal Earth/Ground Resistance Testers & Soil Resist...
 
A te x wall chart
A te x wall chartA te x wall chart
A te x wall chart
 
Drager Polytron Pulsar Fixed Gas Detectors - Spec Sheet
Drager Polytron Pulsar Fixed Gas Detectors - Spec SheetDrager Polytron Pulsar Fixed Gas Detectors - Spec Sheet
Drager Polytron Pulsar Fixed Gas Detectors - Spec Sheet
 
Drager Polytron IR Fixed Gas Detector - Spec Sheet
Drager Polytron IR Fixed Gas Detector  - Spec SheetDrager Polytron IR Fixed Gas Detector  - Spec Sheet
Drager Polytron IR Fixed Gas Detector - Spec Sheet
 
Dräger Polytron 8700 Fixed Gas Detector - Spec Sheet
Dräger Polytron 8700 Fixed Gas Detector - Spec SheetDräger Polytron 8700 Fixed Gas Detector - Spec Sheet
Dräger Polytron 8700 Fixed Gas Detector - Spec Sheet
 
Det23 ds en_v01
Det23 ds en_v01Det23 ds en_v01
Det23 ds en_v01
 
Drager Polytron 8200 Fixed Gas Detector - Spec Sheet
Drager Polytron 8200 Fixed Gas Detector - Spec SheetDrager Polytron 8200 Fixed Gas Detector - Spec Sheet
Drager Polytron 8200 Fixed Gas Detector - Spec Sheet
 

More from Miller Energy, Inc.

Flow & Pressure Instrumentation for Biopharmaceuticals & Life Sciences
Flow & Pressure Instrumentation for Biopharmaceuticals & Life SciencesFlow & Pressure Instrumentation for Biopharmaceuticals & Life Sciences
Flow & Pressure Instrumentation for Biopharmaceuticals & Life SciencesMiller Energy, Inc.
 
One Series Safety Transmitter - Pressure and Temperature Transmitter-Switch
One Series Safety Transmitter - Pressure and Temperature Transmitter-SwitchOne Series Safety Transmitter - Pressure and Temperature Transmitter-Switch
One Series Safety Transmitter - Pressure and Temperature Transmitter-SwitchMiller Energy, Inc.
 
Solenoid Valves for Water Conditioning and Purification Systems and Equipment
Solenoid Valves for Water Conditioning and Purification Systems and EquipmentSolenoid Valves for Water Conditioning and Purification Systems and Equipment
Solenoid Valves for Water Conditioning and Purification Systems and EquipmentMiller Energy, Inc.
 
Special RTD Temperature Sensor Configuration for Heat Trace Applications
Special RTD Temperature Sensor Configuration for Heat Trace ApplicationsSpecial RTD Temperature Sensor Configuration for Heat Trace Applications
Special RTD Temperature Sensor Configuration for Heat Trace ApplicationsMiller Energy, Inc.
 
Maintenance Procedures for Yokogawa ADMAG TI Series AXW Magnetic Flow Meter
Maintenance Procedures for Yokogawa ADMAG TI Series AXW Magnetic Flow MeterMaintenance Procedures for Yokogawa ADMAG TI Series AXW Magnetic Flow Meter
Maintenance Procedures for Yokogawa ADMAG TI Series AXW Magnetic Flow MeterMiller Energy, Inc.
 
Asco Safety Systems Solenoid Valve Selection Guide
Asco Safety Systems Solenoid Valve Selection GuideAsco Safety Systems Solenoid Valve Selection Guide
Asco Safety Systems Solenoid Valve Selection GuideMiller Energy, Inc.
 
Eclipse Model 706 High Performance Guided Wave Radar Level Transmitter
Eclipse Model 706 High Performance Guided Wave Radar Level TransmitterEclipse Model 706 High Performance Guided Wave Radar Level Transmitter
Eclipse Model 706 High Performance Guided Wave Radar Level TransmitterMiller Energy, Inc.
 
Schubert & Salzer Product Overview
Schubert & Salzer Product OverviewSchubert & Salzer Product Overview
Schubert & Salzer Product OverviewMiller Energy, Inc.
 
Mass Flow Controller - Quantim Series
Mass Flow Controller - Quantim SeriesMass Flow Controller - Quantim Series
Mass Flow Controller - Quantim SeriesMiller Energy, Inc.
 
RACO Verbation Alarm Monitoring System Schematic
RACO Verbation Alarm Monitoring System SchematicRACO Verbation Alarm Monitoring System Schematic
RACO Verbation Alarm Monitoring System SchematicMiller Energy, Inc.
 
Quick Coupling Products Guide - Commercial & Industrial
Quick Coupling Products Guide - Commercial & IndustrialQuick Coupling Products Guide - Commercial & Industrial
Quick Coupling Products Guide - Commercial & IndustrialMiller Energy, Inc.
 
Temperature, Pressure, Vacuum, and Differential Switches
Temperature, Pressure, Vacuum, and Differential SwitchesTemperature, Pressure, Vacuum, and Differential Switches
Temperature, Pressure, Vacuum, and Differential SwitchesMiller Energy, Inc.
 
WirelessHART Gas Detector for Toxic and Combustible Gas
WirelessHART Gas Detector for Toxic and Combustible GasWirelessHART Gas Detector for Toxic and Combustible Gas
WirelessHART Gas Detector for Toxic and Combustible GasMiller Energy, Inc.
 
Life Science Applications and Products - Magnetrol
Life Science Applications and Products - MagnetrolLife Science Applications and Products - Magnetrol
Life Science Applications and Products - MagnetrolMiller Energy, Inc.
 
Pump Protection Using Thermal Dispersion Switches
Pump Protection Using Thermal Dispersion SwitchesPump Protection Using Thermal Dispersion Switches
Pump Protection Using Thermal Dispersion SwitchesMiller Energy, Inc.
 
Metal Tube Variable Area Flow Meter
Metal Tube Variable Area Flow MeterMetal Tube Variable Area Flow Meter
Metal Tube Variable Area Flow MeterMiller Energy, Inc.
 
Industrial Valves for Gas Distribution, CNG, LNG
Industrial Valves for Gas Distribution, CNG, LNGIndustrial Valves for Gas Distribution, CNG, LNG
Industrial Valves for Gas Distribution, CNG, LNGMiller Energy, Inc.
 
Magnetrol Non-Contact Radar Level Transmitter Pulsar R86
Magnetrol Non-Contact Radar Level Transmitter Pulsar R86Magnetrol Non-Contact Radar Level Transmitter Pulsar R86
Magnetrol Non-Contact Radar Level Transmitter Pulsar R86Miller Energy, Inc.
 
Trace Moisture Analyzer For Industrial Use
Trace Moisture Analyzer For Industrial UseTrace Moisture Analyzer For Industrial Use
Trace Moisture Analyzer For Industrial UseMiller Energy, Inc.
 

More from Miller Energy, Inc. (20)

Flow & Pressure Instrumentation for Biopharmaceuticals & Life Sciences
Flow & Pressure Instrumentation for Biopharmaceuticals & Life SciencesFlow & Pressure Instrumentation for Biopharmaceuticals & Life Sciences
Flow & Pressure Instrumentation for Biopharmaceuticals & Life Sciences
 
One Series Safety Transmitter - Pressure and Temperature Transmitter-Switch
One Series Safety Transmitter - Pressure and Temperature Transmitter-SwitchOne Series Safety Transmitter - Pressure and Temperature Transmitter-Switch
One Series Safety Transmitter - Pressure and Temperature Transmitter-Switch
 
Solenoid Valves for Water Conditioning and Purification Systems and Equipment
Solenoid Valves for Water Conditioning and Purification Systems and EquipmentSolenoid Valves for Water Conditioning and Purification Systems and Equipment
Solenoid Valves for Water Conditioning and Purification Systems and Equipment
 
Special RTD Temperature Sensor Configuration for Heat Trace Applications
Special RTD Temperature Sensor Configuration for Heat Trace ApplicationsSpecial RTD Temperature Sensor Configuration for Heat Trace Applications
Special RTD Temperature Sensor Configuration for Heat Trace Applications
 
Maintenance Procedures for Yokogawa ADMAG TI Series AXW Magnetic Flow Meter
Maintenance Procedures for Yokogawa ADMAG TI Series AXW Magnetic Flow MeterMaintenance Procedures for Yokogawa ADMAG TI Series AXW Magnetic Flow Meter
Maintenance Procedures for Yokogawa ADMAG TI Series AXW Magnetic Flow Meter
 
Asco Safety Systems Solenoid Valve Selection Guide
Asco Safety Systems Solenoid Valve Selection GuideAsco Safety Systems Solenoid Valve Selection Guide
Asco Safety Systems Solenoid Valve Selection Guide
 
Eclipse Model 706 High Performance Guided Wave Radar Level Transmitter
Eclipse Model 706 High Performance Guided Wave Radar Level TransmitterEclipse Model 706 High Performance Guided Wave Radar Level Transmitter
Eclipse Model 706 High Performance Guided Wave Radar Level Transmitter
 
Schubert & Salzer Product Overview
Schubert & Salzer Product OverviewSchubert & Salzer Product Overview
Schubert & Salzer Product Overview
 
Mass Flow Controller - Quantim Series
Mass Flow Controller - Quantim SeriesMass Flow Controller - Quantim Series
Mass Flow Controller - Quantim Series
 
RACO Verbation Alarm Monitoring System Schematic
RACO Verbation Alarm Monitoring System SchematicRACO Verbation Alarm Monitoring System Schematic
RACO Verbation Alarm Monitoring System Schematic
 
Quick Coupling Products Guide - Commercial & Industrial
Quick Coupling Products Guide - Commercial & IndustrialQuick Coupling Products Guide - Commercial & Industrial
Quick Coupling Products Guide - Commercial & Industrial
 
Temperature, Pressure, Vacuum, and Differential Switches
Temperature, Pressure, Vacuum, and Differential SwitchesTemperature, Pressure, Vacuum, and Differential Switches
Temperature, Pressure, Vacuum, and Differential Switches
 
Current to Pneumatic Converter
Current to Pneumatic ConverterCurrent to Pneumatic Converter
Current to Pneumatic Converter
 
WirelessHART Gas Detector for Toxic and Combustible Gas
WirelessHART Gas Detector for Toxic and Combustible GasWirelessHART Gas Detector for Toxic and Combustible Gas
WirelessHART Gas Detector for Toxic and Combustible Gas
 
Life Science Applications and Products - Magnetrol
Life Science Applications and Products - MagnetrolLife Science Applications and Products - Magnetrol
Life Science Applications and Products - Magnetrol
 
Pump Protection Using Thermal Dispersion Switches
Pump Protection Using Thermal Dispersion SwitchesPump Protection Using Thermal Dispersion Switches
Pump Protection Using Thermal Dispersion Switches
 
Metal Tube Variable Area Flow Meter
Metal Tube Variable Area Flow MeterMetal Tube Variable Area Flow Meter
Metal Tube Variable Area Flow Meter
 
Industrial Valves for Gas Distribution, CNG, LNG
Industrial Valves for Gas Distribution, CNG, LNGIndustrial Valves for Gas Distribution, CNG, LNG
Industrial Valves for Gas Distribution, CNG, LNG
 
Magnetrol Non-Contact Radar Level Transmitter Pulsar R86
Magnetrol Non-Contact Radar Level Transmitter Pulsar R86Magnetrol Non-Contact Radar Level Transmitter Pulsar R86
Magnetrol Non-Contact Radar Level Transmitter Pulsar R86
 
Trace Moisture Analyzer For Industrial Use
Trace Moisture Analyzer For Industrial UseTrace Moisture Analyzer For Industrial Use
Trace Moisture Analyzer For Industrial Use
 

Recently uploaded

NO1 Top Black Magic Specialist In Lahore Black magic In Pakistan Kala Ilam Ex...
NO1 Top Black Magic Specialist In Lahore Black magic In Pakistan Kala Ilam Ex...NO1 Top Black Magic Specialist In Lahore Black magic In Pakistan Kala Ilam Ex...
NO1 Top Black Magic Specialist In Lahore Black magic In Pakistan Kala Ilam Ex...Amil baba
 
Kodo Millet PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
Kodo Millet  PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...Kodo Millet  PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
Kodo Millet PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...pradhanghanshyam7136
 
How to Manage Global Discount in Odoo 17 POS
How to Manage Global Discount in Odoo 17 POSHow to Manage Global Discount in Odoo 17 POS
How to Manage Global Discount in Odoo 17 POSCeline George
 
TỔNG ÔN TẬP THI VÀO LỚP 10 MÔN TIẾNG ANH NĂM HỌC 2023 - 2024 CÓ ĐÁP ÁN (NGỮ Â...
TỔNG ÔN TẬP THI VÀO LỚP 10 MÔN TIẾNG ANH NĂM HỌC 2023 - 2024 CÓ ĐÁP ÁN (NGỮ Â...TỔNG ÔN TẬP THI VÀO LỚP 10 MÔN TIẾNG ANH NĂM HỌC 2023 - 2024 CÓ ĐÁP ÁN (NGỮ Â...
TỔNG ÔN TẬP THI VÀO LỚP 10 MÔN TIẾNG ANH NĂM HỌC 2023 - 2024 CÓ ĐÁP ÁN (NGỮ Â...Nguyen Thanh Tu Collection
 
Holdier Curriculum Vitae (April 2024).pdf
Holdier Curriculum Vitae (April 2024).pdfHoldier Curriculum Vitae (April 2024).pdf
Holdier Curriculum Vitae (April 2024).pdfagholdier
 
2024-NATIONAL-LEARNING-CAMP-AND-OTHER.pptx
2024-NATIONAL-LEARNING-CAMP-AND-OTHER.pptx2024-NATIONAL-LEARNING-CAMP-AND-OTHER.pptx
2024-NATIONAL-LEARNING-CAMP-AND-OTHER.pptxMaritesTamaniVerdade
 
Plant propagation: Sexual and Asexual propapagation.pptx
Plant propagation: Sexual and Asexual propapagation.pptxPlant propagation: Sexual and Asexual propapagation.pptx
Plant propagation: Sexual and Asexual propapagation.pptxUmeshTimilsina1
 
ICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptxICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptxAreebaZafar22
 
Salient Features of India constitution especially power and functions
Salient Features of India constitution especially power and functionsSalient Features of India constitution especially power and functions
Salient Features of India constitution especially power and functionsKarakKing
 
Application orientated numerical on hev.ppt
Application orientated numerical on hev.pptApplication orientated numerical on hev.ppt
Application orientated numerical on hev.pptRamjanShidvankar
 
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...Pooja Bhuva
 
80 ĐỀ THI THỬ TUYỂN SINH TIẾNG ANH VÀO 10 SỞ GD – ĐT THÀNH PHỐ HỒ CHÍ MINH NĂ...
80 ĐỀ THI THỬ TUYỂN SINH TIẾNG ANH VÀO 10 SỞ GD – ĐT THÀNH PHỐ HỒ CHÍ MINH NĂ...80 ĐỀ THI THỬ TUYỂN SINH TIẾNG ANH VÀO 10 SỞ GD – ĐT THÀNH PHỐ HỒ CHÍ MINH NĂ...
80 ĐỀ THI THỬ TUYỂN SINH TIẾNG ANH VÀO 10 SỞ GD – ĐT THÀNH PHỐ HỒ CHÍ MINH NĂ...Nguyen Thanh Tu Collection
 
General Principles of Intellectual Property: Concepts of Intellectual Proper...
General Principles of Intellectual Property: Concepts of Intellectual  Proper...General Principles of Intellectual Property: Concepts of Intellectual  Proper...
General Principles of Intellectual Property: Concepts of Intellectual Proper...Poonam Aher Patil
 
FSB Advising Checklist - Orientation 2024
FSB Advising Checklist - Orientation 2024FSB Advising Checklist - Orientation 2024
FSB Advising Checklist - Orientation 2024Elizabeth Walsh
 
Unit 3 Emotional Intelligence and Spiritual Intelligence.pdf
Unit 3 Emotional Intelligence and Spiritual Intelligence.pdfUnit 3 Emotional Intelligence and Spiritual Intelligence.pdf
Unit 3 Emotional Intelligence and Spiritual Intelligence.pdfDr Vijay Vishwakarma
 
Wellbeing inclusion and digital dystopias.pptx
Wellbeing inclusion and digital dystopias.pptxWellbeing inclusion and digital dystopias.pptx
Wellbeing inclusion and digital dystopias.pptxJisc
 
Sociology 101 Demonstration of Learning Exhibit
Sociology 101 Demonstration of Learning ExhibitSociology 101 Demonstration of Learning Exhibit
Sociology 101 Demonstration of Learning Exhibitjbellavia9
 
Jamworks pilot and AI at Jisc (20/03/2024)
Jamworks pilot and AI at Jisc (20/03/2024)Jamworks pilot and AI at Jisc (20/03/2024)
Jamworks pilot and AI at Jisc (20/03/2024)Jisc
 
Python Notes for mca i year students osmania university.docx
Python Notes for mca i year students osmania university.docxPython Notes for mca i year students osmania university.docx
Python Notes for mca i year students osmania university.docxRamakrishna Reddy Bijjam
 
Interdisciplinary_Insights_Data_Collection_Methods.pptx
Interdisciplinary_Insights_Data_Collection_Methods.pptxInterdisciplinary_Insights_Data_Collection_Methods.pptx
Interdisciplinary_Insights_Data_Collection_Methods.pptxPooja Bhuva
 

Recently uploaded (20)

NO1 Top Black Magic Specialist In Lahore Black magic In Pakistan Kala Ilam Ex...
NO1 Top Black Magic Specialist In Lahore Black magic In Pakistan Kala Ilam Ex...NO1 Top Black Magic Specialist In Lahore Black magic In Pakistan Kala Ilam Ex...
NO1 Top Black Magic Specialist In Lahore Black magic In Pakistan Kala Ilam Ex...
 
Kodo Millet PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
Kodo Millet  PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...Kodo Millet  PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
Kodo Millet PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
 
How to Manage Global Discount in Odoo 17 POS
How to Manage Global Discount in Odoo 17 POSHow to Manage Global Discount in Odoo 17 POS
How to Manage Global Discount in Odoo 17 POS
 
TỔNG ÔN TẬP THI VÀO LỚP 10 MÔN TIẾNG ANH NĂM HỌC 2023 - 2024 CÓ ĐÁP ÁN (NGỮ Â...
TỔNG ÔN TẬP THI VÀO LỚP 10 MÔN TIẾNG ANH NĂM HỌC 2023 - 2024 CÓ ĐÁP ÁN (NGỮ Â...TỔNG ÔN TẬP THI VÀO LỚP 10 MÔN TIẾNG ANH NĂM HỌC 2023 - 2024 CÓ ĐÁP ÁN (NGỮ Â...
TỔNG ÔN TẬP THI VÀO LỚP 10 MÔN TIẾNG ANH NĂM HỌC 2023 - 2024 CÓ ĐÁP ÁN (NGỮ Â...
 
Holdier Curriculum Vitae (April 2024).pdf
Holdier Curriculum Vitae (April 2024).pdfHoldier Curriculum Vitae (April 2024).pdf
Holdier Curriculum Vitae (April 2024).pdf
 
2024-NATIONAL-LEARNING-CAMP-AND-OTHER.pptx
2024-NATIONAL-LEARNING-CAMP-AND-OTHER.pptx2024-NATIONAL-LEARNING-CAMP-AND-OTHER.pptx
2024-NATIONAL-LEARNING-CAMP-AND-OTHER.pptx
 
Plant propagation: Sexual and Asexual propapagation.pptx
Plant propagation: Sexual and Asexual propapagation.pptxPlant propagation: Sexual and Asexual propapagation.pptx
Plant propagation: Sexual and Asexual propapagation.pptx
 
ICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptxICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptx
 
Salient Features of India constitution especially power and functions
Salient Features of India constitution especially power and functionsSalient Features of India constitution especially power and functions
Salient Features of India constitution especially power and functions
 
Application orientated numerical on hev.ppt
Application orientated numerical on hev.pptApplication orientated numerical on hev.ppt
Application orientated numerical on hev.ppt
 
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...
 
80 ĐỀ THI THỬ TUYỂN SINH TIẾNG ANH VÀO 10 SỞ GD – ĐT THÀNH PHỐ HỒ CHÍ MINH NĂ...
80 ĐỀ THI THỬ TUYỂN SINH TIẾNG ANH VÀO 10 SỞ GD – ĐT THÀNH PHỐ HỒ CHÍ MINH NĂ...80 ĐỀ THI THỬ TUYỂN SINH TIẾNG ANH VÀO 10 SỞ GD – ĐT THÀNH PHỐ HỒ CHÍ MINH NĂ...
80 ĐỀ THI THỬ TUYỂN SINH TIẾNG ANH VÀO 10 SỞ GD – ĐT THÀNH PHỐ HỒ CHÍ MINH NĂ...
 
General Principles of Intellectual Property: Concepts of Intellectual Proper...
General Principles of Intellectual Property: Concepts of Intellectual  Proper...General Principles of Intellectual Property: Concepts of Intellectual  Proper...
General Principles of Intellectual Property: Concepts of Intellectual Proper...
 
FSB Advising Checklist - Orientation 2024
FSB Advising Checklist - Orientation 2024FSB Advising Checklist - Orientation 2024
FSB Advising Checklist - Orientation 2024
 
Unit 3 Emotional Intelligence and Spiritual Intelligence.pdf
Unit 3 Emotional Intelligence and Spiritual Intelligence.pdfUnit 3 Emotional Intelligence and Spiritual Intelligence.pdf
Unit 3 Emotional Intelligence and Spiritual Intelligence.pdf
 
Wellbeing inclusion and digital dystopias.pptx
Wellbeing inclusion and digital dystopias.pptxWellbeing inclusion and digital dystopias.pptx
Wellbeing inclusion and digital dystopias.pptx
 
Sociology 101 Demonstration of Learning Exhibit
Sociology 101 Demonstration of Learning ExhibitSociology 101 Demonstration of Learning Exhibit
Sociology 101 Demonstration of Learning Exhibit
 
Jamworks pilot and AI at Jisc (20/03/2024)
Jamworks pilot and AI at Jisc (20/03/2024)Jamworks pilot and AI at Jisc (20/03/2024)
Jamworks pilot and AI at Jisc (20/03/2024)
 
Python Notes for mca i year students osmania university.docx
Python Notes for mca i year students osmania university.docxPython Notes for mca i year students osmania university.docx
Python Notes for mca i year students osmania university.docx
 
Interdisciplinary_Insights_Data_Collection_Methods.pptx
Interdisciplinary_Insights_Data_Collection_Methods.pptxInterdisciplinary_Insights_Data_Collection_Methods.pptx
Interdisciplinary_Insights_Data_Collection_Methods.pptx
 

Magnetrol Guide Wave Radar Level Transmitter For Hygienic Applications

  • 1. Eclipse® Enhanced Model 705 GWR Level Transmitter for Hygienic Applications F E A T U R E S • Two-wire, 24 VDC, loop-powered transmitter for level, interface, or volume • HART® , FOUNDATION fieldbus™ or PROFIBUS PA digital communications • Performance not process dependent (changing specific gravity and dielectric constant have no significant effect) • Designed to BPE Standards • No level change needed for configuration; no field calibration necessary • 20-point custom strapping table for volumetric or flow measurement • Can measure reliably to very top of vessel and to the bottom of the probe • Probes available in 316L SS, AL6XN and Hastelloy® C22 (15Ra MAX electropolished probe rod finish) • Standard C of C documentation included. (The C of C includes certification of o-rings, PTFE, and PEEK as 21CFR-177 GRAS and USP <88> Class VI at 121 °C, and metallic material CMTRs and surface finish specification.) • IS, XP, and Non-Incendive approvals • Two-line, 8-character LCD and 3-button keypad (opt.) • Quick connect/disconnect probe coupling • Third Party Safety Integrity Level (SIL) data (FMEDA analysis) for Safety Instrument Systems engineering is available. (HART® version.) D E S C R I P T I O N The Enhanced Eclipse® Model 705 is a loop-powered, 24 VDC, level transmitter based upon the revolutionary Guided Wave Radar (GWR) technology. This transmitter offers enhanced reliability, as demonstrated by a Safe Failure Fraction of 91% (suitable for SIL2 applications). This ECLIPSE transmitter is designed to provide meas- urement price/performance well beyond that of all traditional technologies. ECLIPSE supports the FDT/DTM standard and a PACTware™ PC software package allows for additional configuration and trending flexibility. T E C H N O L O G Y ECLIPSE Guided Wave Radar is based upon the tech- nology of TDR (Time Domain Reflectometry). TDR utilizes pulses of electromagnetic energy transmitted down a probe. When a pulse reaches a surface that has a higher dielectric than the air/vapor in which it is traveling, the pulse is reflected. Ultra high-speed tim- ing circuit precisely measures the transit time and pro- vides an accurate level measurement. ECLIPSE GWR can be utilized to detect overall level or interface level, and when used with a HART® splitter, it can transmit two 4–20 mA signals. A P P L I C A T I O N S MEDIA: Liquids or slurries; hydrocarbons to water- based media (dielectric 1.9–100). VESSELS: Most process or storage vessels, up to rated probe temperature and pressure. CONDITIONS: Virtually all level measurement and con- trol applications including process conditions exhibiting visible vapors, foam, coating/buildup, surface agitation, bubbling or boiling, high fill/empty rates, low level and varying dielectric media or specific gravity. SIL 2 BPE Miller Energy, Inc. | Exton, PA | 610-363-6200 | www.millerenergy.com
  • 2. T R A N S M I T T E R S P E C I F I C A T I O N S Reference conditions Reflection from water at +70 °F (+20 °C) with 72" (1.8 m) single rod probe in metal vessel (CFD threshold) Linearity ¿ < 0.1% of probe length or 0.1 inch (3 mm) (whichever is greater) Measured error ¿ ±0.1% probe length or ±0.1 inch (3 mm) maximum Resolution ¡ ±0.1 inch (1 mm) Repeatability ¡ < 0.1 inch (±0.025% of Volume) Hysteresis ¡ < 0.1 inch (1 mm) Response time < 1 second Warm-up time < 5 seconds operating temperature range -40 to +175 °F (-40 to +80 °C) LCD readable temperature range -5 to +160 °F (-20 to +70 °C) operating temperature effect ±0.02% of probe length / °C Humidity 0-99%, non-condensing Electromagnetic compatibility Meets CE requirements (EN 61000-6-2/2001, EN 61000-6-4/2001) (Probes must be used in metallic vessel to maintain CE compliance) SIL 2 (optional) Safe Failure Fraction (SFF) 91% P E R F O R M A N C E F U N C T I O N A L / P H Y S I C A L 2 ¿ Specification for top 12 inches of single rod probe will be application dependent. ¡ When used with strapping table Signal output 4–20 mA with HART, 3.8 to 20.5 mA usable (meets NAMUR NE 43) FOUNDATION fieldbus™ H1(ITK4.6) (optional) PROFIBUS PA (optional) Span 6 inches to 20 feet (15 to 610 cm) Resolution Analog 0.01 mA Display 0.1 inches or cm Loop resistance 630 Ω @ 24 VDC (20.5 mA) Damping Adjustable 0–10 seconds Diagnostic alarm Adjustable 3.6 mA, 22 mA, or HOLD User interface 3-button keypad, HART communicator, FOUNDATION fieldbus™ , PROFIBUS Display 2-line × 8-character LCD Power (at terminals) General purpose/Intrinsically safe 11 to 36 VDC Explosion proof (with intrinsically safe probe) 11 to 36 VDC FoUnDAtIon fieldbus/PRoFIBUS PA: General Purpose/XP 9 to 32 VDC FoUnDAtIon fieldbus/PRoFIBUS PA: IS/Fisco 9 to 30 VDC Menu language English, Spanish, French and German Housing material 304 stainless steel deep drawn Aluminum A356T6 (< 0.2% copper) (optional) net/Gross weight 304 stainless steel 3 lbs (1.36 kg) / 4 lbs (1.81 kg) Aluminum 6 lbs (2.72 kg) / 7 lbs (3.18 kg) overall dimensions 304 stainless steel H 4.5" (114mm) x W 3.0" (76mm) Aluminum H 8.43" (214 mm) x W 4.38" (111 mm) × D 7.40" (188 mm)
  • 3. 3 A G E N C Y A P P R O V A L S FM 705-5XXX-1XX Intrinsically Safe ¿ Class I, Div. 1; Groups A, B, C, & D 705-5XXX-2XX Class II, Div. 1; Groups E, F, & G T4 Class III, Type 4X, IP66 Entity 705-5XXX-3XX Explosion Proof ¡ Class I, Div. 1; Groups B, C & D 705-5XXX-4XX (with Intrinsically Safe probe) Class II, Div. 1; Groups E, F, & G T4 Class III, Type 4X, IP66 705-5XXX-XXX Non-Incendive Class I, Div. 2; Groups A, B, C, & D 705-5XXX-XXX Suitable for: ¬ Class II, Div. 2; Groups F & G T4 Class III, Type 4X, IP66 CSA 705-5XXX-1XX Intrinsically Safe Class I, Div. 1; Groups A, B, C, & D 705-5XXX-2XX Class II, Div. 1; Group E, F & G T4 Class III, Type 4X Entity 705-5XXX-3XX Explosion Proof ¡ Class I, Div. 1; Groups B, C & D 705-5XXX-4XX (with Intrinsically Safe probe) Class II, Div. 1; Group E, F & G T4 Class III, Type 4X 705-5XXX-XXX Non-Incendive Class I, Div. 2; Groups A, B, C, & D 705-5XXX-XXX Suitable for: ¬ Class II, Div. 2; Group E, F & G T4 Class III, Type 4X IEC 705-5XXX-AXX Intrinsically Safe √ Zone 0 Ex ia IIC T4 705-5XXX-BXX ATEX 705-5XXX-AXX Intrinsically Safe √ II 1G, EEx ia IIC T4 705-5XXX-BXX 705-5XXX-CXX Flame Proof II 1/2G, EEx d [ia] IIC T6 705-5XXX-DXX 705-51XX-EXX Non-sparking II 3(1)G, EEx nA [ia] IIC T4..T6 705-51XX-FXX with probe II 1 G EEx ia IIC T6 705-52XX-EXX II 3(1)G, EEx nA [nL] [ia] IIC T4..T6 705-52XX-FXX with probe II 1 G EEx ia IIC T6 AGENCY MODEL APPROVED APPROVAL CATEGORY APPROVAL CLASSES ¿ Hygienic enclosure is an “end of line” device. Enclosure contains a single conduit entry. Second conduit entry is plugged and sealed. ¡ Factory Sealed: This product has been approved by Factory Mutual Research (FM), and Canadian Standards Association (CSA), as a Factory Sealed device. ¬ IMPORTANT: Measured media inside vessel must be non-flammable only. If media inside vessel is flammable, then the explosion proof version (which contains an internal barrier making the probe Intrinsically Safe) is required. √ Special conditions for safe use Because the enclosure of the Guided Wave Radar Level Transmitter ECLIPSE Model 705-5_ _ _-_1_ and/or Probe ECLIPSE Model 7_ _-_ _ __-_ __ is made of aluminum, if it is mounted in an area where the use of category 1 G (Zone 0) apparatus is required, it must be installed such, that, even in the event of rare incidents, ignition sources due to impact and friction sparks are excluded. For applications in explosive atmospheres caused by gases, vapours or mists and where category 1G (Zone 0) apparatus is required, electrostatic charges on the non-metallic parts of the Probe ECLIPSE Model 7x5-_ _ __-___, Model 7x7-_ _ __-___ and Model 7_F-_ _ __-___ shall be avoided. These units are in conformity of: 1. The EMC Directive: 2004/108/EC. The units have been tested to EN 61326. 2. Directive 94/9/EC for equipment or protective system for use in potentially explosive atmospheres. 0344 Note: Single and twin rod probes must be used in metallic vessel or stillwell to maintain CE compliance.
  • 4. S I N G L E R O D P R O B E S The pulses of energy from a single rod probe develop between the center rod and the mounting nut or flange. In other words the pulse propagates down the rod as it references its ground at the top of the tank. The efficiency of the pulse “launch” is directly related to how much metallic surface exists around it at the top of the vessel. Figure 1 shows the single element design and how the pulse expands into a teardrop shape as it propagates away from the top of the tank (ground reference). Because the design is “open,” it is the most forgiving of coating and buildup. It is important to note that a parallel metal wall INCREASES its performance while a singular, metal object protruding near the probe may be improperly detected as a liquid level. P R O B E O V E R V I E W Figure 1 Single Rod Probe P A C T W A R E P C S O F T W A R E P R O G R A M PACTware PC software and the new Field Device Tool (FDT) standard take radar level measurement to a new level of setup efficiency and user-friendliness. The powerful ECLIPSE guided wave radar transmitter with its linear program has always been easy to use. PACTware builds on that ease of use by adding a graphical software interface. Simply connect your PC through a serial interface to the HART loop and all functionality can be accessed quickly, conveniently, and safely. Refer to PACTware bulletins 59-101 and 59-601 for more information. PACTware offers distinct advantages in loop tuning and configuration documentation. 4
  • 5. P R O B E O V E R V I E W ( c o n t . ) N O Z Z L E S The 7xF and 7xH Single Rod probes may be susceptible to objects that are in close proximity. The following rules should be followed for proper application: 1. Nozzle must be 3 ⁄4" (19 mm) diameter (A) or larger. 2. Ratio of diameter (A) to length (B) is 1:1 or greater. Any ratio < 1:1 (e.g., a 2" × 6" nozzle = 1:3) can be used but may require a BLOCKING DISTANCE and/or SENSITIVITY adjust- ment. See Figure 2. 3. Pipe reducers that create restriction should not be used. See Figure 3. Figure 2 Figure 3 A B 5 O B S T R U C T I O N S ( M E T A L L I C ) 1. If PACTware is used for loop tuning, objects (e.g., shoulders or agitator blades) can be within 1 ⁄4" of probe. T U R B U L E N C E The bottom of a single rod probe should be stabilized if turbu- lence will cause a deflection of more than 3 inches (80 mm) at 10 feet (3 m) of length. A metallic capture ring can be employed at the bottom of the probe to eliminate torque buildup. Distance to probe Acceptable objects < 0.5" (13 mm) Continuous, smooth, parallel, conductive surface (e.g., tank wall); probe should not touch tank wall Obstructions (Metallic) – Guidelines Figure 4 P R O C E S S S E A L T E M P E R A T U R E / P R E S S U R E C H A R T 0 100 200 50 100 300200 ProcessPressure(psig) Process Temperature (°F) (max. 300) 7XF/7XH Note: Tri-clamp connection service rating may further limit pressure. 0 6.9 13.8 10 38 15093 ProcessPressure(bar) Process Temperature (°C) (max. 150) 7XF/7XH
  • 6. P R O B E & H O U S I N G F E A T U R E S Stainless Steel Housing with Model 7xH Hygienic probe ECLIPSE Model 705 transmitter in a 304 SS housing for use in a variety of hygienic applications. 0.5-inch diameter 316L SS probe with a 15Ra MAX surface finish is available with lengths up to 244" and with Tri-Clover® type connection sizes from 1" through 4". In addition, a 0.25-inch diameter 316L SS probe with 15Ra MAX surface finish is available with lengths up to 72" and with a 3 ⁄4" Tri-Clover® type connection. 11 ⁄2" Hygienic Connection with bend 316L SS probes can be bent to avoid internal obstruc- tions such as agitator blades and spray balls, and to ensure lowest possible level detection. 3 ⁄4" Hygienic Connection without bend 0.25-inch diameter probes suitable for use in smaller vessels where space is at a premium. Available in lengths up to 72 inches. Aluminum Dual Compartment Housing ECLIPSE Model 705 transmitter is available with an industrial dual compartment aluminum housing. 6 Segmented Hygienic Probe Segmented probes are available should the probe be inserted or removed with limited headroom above the vessel (segmented lengths are specified by the cus- tomer). Contact the factory for details.
  • 7. R E M O T E A S S E M B L Y The Local/Remote assembly is meant to be a simple and cost-effective way to remove the transmitter electronics and locate it a short distance away from the probe. The assembly allows a remote distance of 33" (84 cm) or 144" (3650 cm) which offers a greater degree of flexibility during installation. It is supplied with a remote bracket and flexible armor conduit as a complete assembly. This can be employed with both styles of housings. 7 33.00 or 144.00 (838 or 3650) 3.75 (95) 3.00 (76) 2.75 (70) 2.00 (51) 3.50 (89) 2 Holes .38 (10) Dia. 3.08 (78) 2.12 (54) Elect. Conn. Qty. 2 43° 2.53 (64) 4.00 (100) ECLIPSE Hygienic Remote Configuration 4.28 (109) 4.43 (113) 45° View ECLIPSE Hygienic Housing (45° View) I N C H E S ( M M ) D I M E N S I O N A L S P E C I F I C A T I O N S I N C H E S ( M M ) — S I N G L E R O D P R O B E S ECLIPSE Hygienic Housing (shown with 7xF-E Hygienic Probe) Probe Insertion Length 8.94 (227) 7xF-E: 9.25 (235) 7xH: Process Connection Electrical Connection Ø 0.50" (12) Rod 2.53 (64) 2.17 (55) 3.02 (77)
  • 8. S I N G L E R O D P R O B E M A T R I X 7xF-E, -F, -G and 7xH Hygienic 8 ¿ Contact factory for applications requiring probe lengths less than 24" (60 cm). ¡ Refer to Process Temperature vs. Process Pressure Graph ¬ εr 1.9–10 must be mounted between 2–6" (50–150 mm) of metal tank wall. BPE Recommended For Applications demanding hygienic specifications Not Recommended For Low dielectric media (εr < 1.9) Materials/Wetted Metallic Parts 7EF: 316L SS, <15 Ra electropolished finish (Optional: Hastelloy C, AL6XN SS) 7EH: 316L SS, <15 Ra electropolished finish (Optional: Hastelloy C, AL6XN SS) Elastomer and Polymeric Wetted Parts 7EF: PTFE (GRAS 21CFR177-1550 and USP <88> Class VI at 121 °C) 7EH: PEEK and O-ring (Viton or EPDM) (GRAS 21CFR177 and USP <88> Class VI at 121 °C) Diameter ∅.50 (13 mm) rod for process connections > 3 ⁄4" (24–240 inches) ∅ .25 (7 mm) for process connections = 3 ⁄4" (24–72 inches) Flange ANSI (DIN) 3 ⁄4 to 4" (38 to 100 cm); Tri-Clamp® fitting Length ¿ 24 to 240" (60 to 610 cm) for Tri-Clamp process connections equal to 1" or greater 24 to 72" (61 to 183 cm) for 3 ⁄4" Tri-Clamp type process connection Transition Zone Top Bottom 1" (25 mm) @ εr > 10 1" (25 mm) @ εr > 10 Blocking Distance Top 0–36" (0–91cm) probe length/application dependent Process Temperature ¡ (Max.) Min. (Cryogenic) +300 °F @ 200 psig (+150 °C @ 13.8 bar) Consult factory Process Pressure Max. Min. (Vacuum Service) 200 psig @ +300 °F (13.8 bar @ +150 °C) or limit of tri-clamp service rating, whichever is lower N/A Dielectric ¬ 1.9 to 100 Max. Viscosity (cP) 10,000 (consult factory if severe agitation/turbulence) Mounting Effects See Nozzles and Obstructions on page 5 Coating/Buildup Yes; maximum error 10% of coated length; % of coated length; % error related to dielectric of media, thickness of coating & coated probe length above media Foam Yes Corrosives Yes Hygienic Yes Overfill No Approvals FM CSA ATEX OTHER Yes Yes Yes No
  • 9. T Y P I C A L H Y G I E N I C A P P L I C A T I O N S The Model 705 transmitters are presently installed in a variety of media systems including bioreactors, fermentors, media storage, crystallizers, decanters, ultra filtration skid receivers, cook kettles, CIP systems, balance tanks, mixing tanks, storage tanks, etc. 25K Liter Reactor Tulip Tank1500K Liter Fermentor or Mix Tank Utility systems including: • ammonia storage • CO2 storage • inlet water • deaerator systems • condensate receivers • boiler drums • fuel oil storage • various sumps • waste tanks • neutralization tanks • kill vessels Buffer systems, Media Systems and Filtration including: • primary mix tanks • hold tanks • day tanks • bulk tanks CIP systems including: • wash and rinse tanks • bulk tanks • skid delivery tanks 9
  • 10. 0 None – SIL 1 Standard Electronics (SFF=84.5%) A SIL 2 (Certified) Enhanced Electronics (SFF=91%) ¿ 0 3 ⁄4" NPT 1 M20 4 1 ⁄2" NPT ¬ 1 Cast aluminum, dual compartment, 45° angle 2 316L stainless steel, dual compartment, 45° angle 3 304 stainless steel, single compartment ¡ 7 Cast aluminum, dual compartment, 12-foot remote 8 316L stainless steel, dual compartment, 12-foot remote 9 304 stainless steel, single compartment, 12-foot remote ¡ 0 Digital display and keypad with blind cover A Digital display and keypad with window cover M O D E L N U M B E R T R A N S M I T T E R 10 SIGNAL OUTPUT 7 0 5 5 5 24 VDC, Two-wire BASIC MODEL NUMBER POWER ACCESSORIES CONDUIT CONNECTION MOUNTING/CLASSIFICATION OPTIONS HOUSING Models available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). 705 ECLIPSE Guided Wave Radar Level Transmitter 1 Integral, General Purpose & Intrinsically Safe (FM & CSA), Non-incendive (Class I, Div. 2) 2 3-foot Remote, General Purpose & Intrinsically Safe (FM & CSA), Non-incendive (Class I, Div. 2) 3 Integral, Explosion Proof (FM & CSA) & Non-incendive 4 3-foot Remote, Explosion Proof (FM & CSA) & Non-incendive A Integral, General Purpose & Intrinsically Safe (ATEX & JIS EEx ia IIC T4) B 3-foot Remote, General Purpose & Intrinsically Safe (ATEX & JIS EEx ia IIC T4) C Integral, Explosion Proof (ATEX EEx d [ia] IIC T6) (must be ordered with Conduit Connection Codes 0 and 1) D 3-foot Remote, Explosion Proof (ATEX EEx d [ia] IIB T6) (must be ordered with Conduit Connection Codes 0 and 1) E Integral, Non-incendive (ATEX EEx n II T4..6) F 3-foot Remote, Non-incendive (ATEX EEx n II T4..6) 1 4–20 mA with HART 2 FOUNDATION fieldbus™ Digital Communication (English only) 3 PROFIBUS PA Digital Communication (English Only) ¿ Not available with Model 7xH Probe ¡ Not available with conduit connection code 0 ¬ Not available with explosion proof Mounting/Classification codes 3, 4, C, D.
  • 11. MATERIAL OF CONSTRUCTION 7E ECLIPSE GWR probe, English unit of measure 7M ECLIPSE GWR probe, Metric unit of measure 7 P BASIC MODEL NUMBER M O D E L N U M B E R P R O B E O-RINGS 11 CONFIGURATION/STYLE E Hygienic, 316L stainless steel (15 Ra EP finish) G Hygienic, AL6XN stainless steel (15 Ra EP finish) H Hygienic, Hastelloy C22 (15 Ra EP finish) 2P 3 ⁄4" Tri-Clover® type, 16 AMP Hygienic Flange (only available with 3rd digit F) 3P 1" or 11 ⁄2" Tri-Clover® type, 16 AMP Hygienic Flange 4P 2" Tri-Clover® type, 16 AMP Hygienic Flange 5P 3" Tri-Clover® type, 16 AMP Hygienic Flange 6P 4" Tri-Clover® type, 16 AMP Hygienic Flange 9P 21 ⁄2" Tri-Clover® type, 16 AMP Hygienic Flange HYGIENIC FLANGE CONNECTIONS PROCESS CONNECTION SIZE/TYPE 24 to 240 inches (60 to 610 cm) ¿ (unit of measure is determined by second digit of Model Number) Examples: 24 inches = 024; 60 centimeters = 060 LENGTH Insertion Length Hygienic Flange ¿ Contact factory for applications requiring probe lengths less than 24" (60 cm). F Hygienic Single Rod (with PTFE seal) H Hygienic Single Rod (with O-Ring seal) 1 EPDM (only available with 3rd digit H) C Viton® GF (only available with 3rd digit H) N None (only available with 3rd digit F)
  • 12. The quality assurance system in place at Magnetrol® guarantees the highest level of quality throughout the company. MAGNETROL is committed to providing full customer satisfaction both in quality products and quality service. The MAGNETROL quality assurance system is registered to ISO 9001 affirming its com- mitment to known international quality standards providing the strongest assurance of product/service quality available. Several Models of ECLIPSE Guided Wave Radar Transmitters are available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). Models covered by ESP service are color coded in the selection data charts. To take advantage of ESP, simply match the color coded model number codes (standard dimensions apply). ESP service may not apply to orders of ten units or more. Contact your local representa- tive for lead times on larger volume orders, as well as other products and options. Expedite Ship Plan All MAGNETROL electronic level and flow controls are warranted free of defects in materials or workmanship for eighteen months from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be cov- ered under the warranty; then, MAGNETROL will repair or replace the control at no cost to the purchaser (or owner) other than transportation. MAGNETROL shall not be liable for misap- plication, labor claims, direct or consequen- tial damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some MAGNETROL products. BULLETIN: 57-110.11 EFFECTIVE: March 2017 SUPERSEDES: July 2016 705 Enterprise Street • Aurora, Illinois 60504-8149 • 630-969-4000 • Fax 630-969-9489 info@magnetrol.com • www.magnetrol.com Copyright © 2017 Magnetrol International, Incorporated. Performance specifications are effective with date of issue and are subject to change without notice. For additional information, see Instruction Manual 57-600. ECLIPSE Guided Wave Radar transmitters may be protected by one or more of the following U.S. Patent Nos. US 6,062,095: US 6,247,362; US 6,588,272; US 6,626,038; US 6,640,629; US 6,642,807; US 6,690,320; US 6,750,808; US 6,801,157. May depend on model. Q U A L I T Y E S P W A R R A N T Y Magnetrol, Magnetrol logotype and Eclipse are registered trademarks of Magnetrol International, Incorporated. HART® is a registered trademark of the HART Communication Foundation. Hastelloy® is a registered trademark of Haynes International. Monel® is a registered trademark of the INCO family of companies. PEEK™ is a trademark of Vitrex plc. Teflon® is a registered trademark of DuPont. Tri-Clamp is a registered trademark of Ladish Co. Tri-Clover® is a registered trademark of Tri-Clover, Inc. Viton® and Kalrez® are registered trademarks of DuPont Performance Elastomers.