1. Compressors for
R290 systems
Technological Innovations In Refrigeration And Air
Conditioning
Equipment, Components, Certifications
The Fgas Revolution And
The Phase Down
Aggiornamento al
XVI CONVEGNO EUROPEO
organizzato da:
Centro Studi Galileo
Associazione dei Tecnici italiani del Freddo
Johari Gregorio
7. 7
- Plug-in commercial cabinets:
Hydrocarbons are the main Embraco (and market) choice
- Barriers for HC technologies
- Legislation evolution
- Possible options to increase safety of HC on appliances
Hydrocarbons
8. 8
BARRIERS FOR HC TECHNOLOGY
PEOPLE TRAINING
FOR CABINET
SERVICING
INITIAL INVESTMENTS
150 GRAMS CHARGE LIMIT
GOV. INCENTIVES RECOMMENDED
TECHNICIANS CERTIFICATION
HAS TO INCLUDE HC
REFRIGERANT SERVICING
EXISTING INTERNATIONAL SAFETY
STANDARDS LIMIT HC REFRIGERANT
CHARGE FOR LIGHT COMMERCIAL
APPLIANCES
17. 17
New platform for Propane
Excellent cooling capacity out of compact platform (Mini)
Cooler – up to 700 liters,
Chest Freezer, Ice cream cabinet – up to 500 liters
Top efficiency
L/MBP -35 to 0°C (freezers and coolers)
Value proposition
18. 18
Project Description
Key Driver: Improve product performance to meet market demand for high efficiency solutions
Based on NEK platform with new high efficiency features
HIGH EFFICIENCY MODELS
MAIN APPLICATIONS
All applications
NEU vs NEK
Refrigerant Cooling capacity EER
R290 +4 to 7% +5 to 8%
R134a (HBP) +7 to 10% +7 to 12%
R404A +7 to 10% +8 to 16%
PERFORMANCES
20. 20
VNE
VEG
R290
Compressor Inverter
Model
Displac.
[cc]
Appl.
Capacity Range
(Min/Max)
Efficiency
(Min. Speed)
Speed
Range
[RPM]
Stand.
Input
Voltage
[V]
Output
Power
[W]
Control
Mode
[Btu/h] [W] [W/W]
VESA7U 7
L/MBP
680-1360 200-400 1,70 2000-4500 ASHRAE
LBP
115 / 220 320
Drop-in;
Serial or
Frequency
VEGT8U 8 700-1975 205-570 1,60 1800-4500 115 500
VNEK207U 7,3
LBP
446-976 131-286 1,14
2000-4500
EN12900
LBP
220
500
VNEU213U 13,5 897-1954 263-573 1,28 800
VNEU217U 16,8 1188-2395 348-702 1,29 1000
R134a
Compressor Inverter
Model
Displac.
[cc]
Appl.
Capacity Range
(Min/Max)
Efficiency
(Min. Speed)
Speed
Range
[RPM]
Stand.
Input
Voltage
[V]
Output
Power
[W]
Control
Mode
[Btu/h] [W] [W/W]
VEMY6HH 6 L/M/HBP 340-790 100-231 1,66 1600-4500
ASHRAE
LBP
115V;
220V
320
Drop-in;
Serial or
Frequency
VEGT8HB 8
L/MBP
412-1108 121-325 1,60
1800-4500
VEGT11HB 11 653-1463 191-429 1,56
220V
320/500
VNEK610Z 10
HBP
2150-4200 630-1231 2,55
2000-4500
EN12900
HBP
800
VNEK614Z 14,3 3090-5587 905-1637 2,46 1000
R404A
Compressor Inverter
Model
Displac.
[cc]
Appl.
Capacity Range
(Min/Max)
Efficiency
(Min. Speed)
Speed
Range
[RPM]
Stand.
Input
Voltage
[V]
Output
Power
[W]
Control
Mode
[Btu/h] [W] [W/W]
VNEK206GK 6,2
LBP
430-894 126-262 0,99
2000-
4500
EN12900
LBP
220V
500
Drop-in;
Serial or
Frequency
VNEK212GK 12,1 836-1586 245-465 1,11 1000
VNEK606GK 6,2
MBP
1298-2735 380-801 1,78 EN12900
MBP
800
VNEK609GK 8,8 1822-3699 534-1084 1,83 1000
FullMotion portfolio for Commercial Application
VES
VEM
21. 21
FullMotion R290 Vs On Off R404A
Up to 184€ / yr*
* 0,20€/kWh
Island merchandizer
Compressor
R404A
ref
R290
VNEU213U
Diff.
AVG. Load line Temp.
H : 550 mm [°C]
-18.3 °C -18.5 °C
Function ratio [%] 72.9 86.0 18%
Energy consumption
[kWh / 24h]
7.808 5.287 -32%
NOTE: VNEU - refrigerant charge 137g R290
Energy saving/day [kWh] 2,52
Energy saving/yr [kWh] 920
Energy bill saving/yr [€]* 184
Return on Investment < 1 yr
22. 22
Compressor
Baseline
A
Top Efficiency
On-Off
VESD11C
Drop-in
EMC3121U
PTC + rc 5uF
Refrigerant R600a 65gr. R290 56gr.
Energy
consumption*
Th settings Original thermostat Original thermostat Original thermostat
AVG. Speed N/A 1440 N/A
RTR 56,5% 91,3% 46,6%
Cycles/h 3,5 0,5 3,3
Consumption
[kWh/24h]
1,477 0,978 1,321
Energy Saving Ref. -34% -11%
R600a vs R290
Ice Cream Freezer 300 l – Slide Glass
* without load @25°C
Up to 40€ / yr*
23. 23 EMBRACO PROPRIETARY CONFIDENTIAL INFORMATION23
Propane can be considered as most sustainable
refrigerant for light commercial segment because of
both, direct and indirect emissions
R290 offers an excellent option to meet F-Gases
regulations and energy standards.
With 150g of propane charge it’s possible to cover
most of unitary, plug-in applications
An international effort to increase HC charge limit
in -89 standard to cover all plug in range with
single circuit solution is in progress
Editor's Notes
Our strategic footprint is a key element in our business.
Need to clarify GTZ and SNAP approval – I think this is EPA