- 1. 10" SONO TUBE FOOTINGS FOR
BREEZEWAY COLUMNS, PROVIDE
3 #4 REINFORCING, TYP. -
SLAB (3-0" ABOVE
BASEMENT SLAB)
st-
CD
CD
C/L
C/L
© ©
C/L
9
T.O. GARAGE FOUNDATION
=F
EL. -0-5'
T.O. GARAGE FOUNDATION AT FRONT OPENINGS
EL. -2-8" *
SLAB ON GRADE
ABOVE
*
T.O. GARAGE FOUNDATION AT SOUTH DOOR
EL. -2-1 3/4
CM
i
Is-
i
oo
6" CONCRETE GARAGE FOUNDATION W^LL, TYP
2-0" CONCRETE FOOTING, TYP
7-0
11
THROUGH-WALL
INSTRUMENTATION
CONDUIT TO GARAGE
t
C
o
2
1
■7 ~
26-0' 16’-0"
-7 ~ y-
CO
o
CM
1
Ob
00
1
Ob
F
E
E.1
CO
00
CO
C.1
.u
CD
1
LO
O
1
CM
o
t 4ft
BOTTOM OF FOUNDATION WALL
DETAIL, TYP; SEE 1/A-506
Dimension
Dimension Line
Indicates distance
from outside edge of
wall to outside edge
of wall
Extension Line
Leader Line
TYP = Typical Note
Elevation Symbol
T.O = Top Of... C/L = Center Line
Detail
Call-out =
See Detail 1
on Sheet
A-506
Shows dimension
from edge of wall to
center line of column
Location Reference Mark
or
Column Line Refence
Hidden Line
PLAN VIEW = View from the top
N
S
E W
Typical orientation UNO (Unless Noted Otherwise)
- 2. B D F
A.1 A
1
A-304
SOIL GAS
VENT
12
12 4
4
R2
12 12
9.67 9.67
4 B.O. CEILING JOISTS ALIGN
EL. +19-7 1/4ii
2k 2k 2k
2
D
©
(*>
B
12
12
22 12
9.67
12 9.67 4
4
12
4
$
T.O. SECOND FLOOR SUBFLOOR
EL. +10-6 1/411
ALIGN
$
B.O. FLOOR JOISTS 2k
±k 2k 2k.
EL. +9'-3 3/811
© F F
28
I
CONDUIT FOR FUTURE GAS
FURNACE SUPPLY/EXHAUST A A
© E3
U E3 □ E3 □ E3
E4
T.O. FIRST FLOOR SUBFLOOR F'0 F9
F4 F10 E11 E11
$
Or
EL. +0-2 3/8
II
CONNECTION FOR
FUTURE MULTISPLIT
OUTDOOR UNIT 1'5
T.O. FOUNDATION WALL r
/
CONDUIT SUMP
PUMP OUTLET r
EL. +0-0 CONNECTION
FOR FUTURE
AIR-TO-AIR
OUTDOOR UNIT
CONNECTION
FOR CENTRAL
AIR-TO-AIR
OUTDOOR UNIT
CONNECTION FOR FUTURE
HIGH VELOCITY HVAC
AIR-TO-AIR OUTDOOR UNIT
(SEE GENERAL SHEET
NOTE #10)
JHI
Jt
B
J'L
l_ J
RIGHTSIDE(EAST)ELEVATION
2 SCALE: 1/4" = 1'-0"
Elevation View = Side view from the outside
Section Cut - See Section
1 on Sheet A-304
(shown below)
3 4 6
5 7
2'-0" 32'-0' 2'-0" 8'-0"
-><- -><-
UNVENTED UPPER ROOF ASSEMBLY:
ASPHALT SHINGLES,
CONTINUOUS FULLY-ADHERED PEEL AND STICK ROOF MEMBRANE,
PLYWOOD SHEATHING WITH H-CLIPS,
5" OF FOIL-FACED POLYISOCYANURATE IN 3 LAYERS (1-1/2", 2", 1-1/2"
CONTINUOUS FULLY-ADHERED AIR BARRIER MEMBRANE
1/2" PLYWOOD SHEATHING WITH H-CLIPS,
1-3/4" X 11-7/8" LSL ENGINEERED ROOF RAFTERS AT 24" 0,C,
CELLULOSE INSULATION,
4" GWB
5
A-508
4 T.O. ROOF RIDGE
EL. +27'-5 3/8"
T.O. 4/12 ROOF STRUCTURAL RIDGB
IN SECTION
$
= l
F^DGE
EL. +26-11 1/2
y 2
4 T.O. 9.67/12 ROOF STRUCTURAL
I/
y
EL. +26-10 1/8 A-508
I
1'--’
L
1-4"
T -
VF y
LI
4 B.O. CEILING JOISTS
FF
EL. +19'-7 1/4
1'-4"
T-4'
— ATTIC ASSEMBLY:
1%" x 114 " LSL ENGINEERED
JOISTS AT 24" O.C.,
I' GWB y
CN
M
o
3 r-4"
CD
/
4
A-508
-------
_ _ 1
4 T.O. SECOND FLOOR SUBFLOOR £3 . =L
l
EL. +10'-6 1/4"
I f
■ 2r = ±(-|s
4 B.O. FLOOR JOISTS
— 2ND FLOOR ASSEMBLY:
T & G FLOOR SHEATHING,
14" DEEP OPEN WEB WOOD JOIST AT 24" O.C.,
I' GWB
EL. +9'-3 3/8"
eg
OPEN CELL SPRAY
FOAM INSULATION
(0.5 PCF) AT RIM
JOIST OF 1ST AND
2ND FLOOR FRAMING
o
CT>
4 T.O. FIRST FLOOR SUBFLOOR
y
EL. +0'-2 3/8"
T.O. FOUNDATION WALL 1
4 o
EL. +0'-0
GRADE
4 ■1 r-
EL. -0'-3 5/8’
4 T.O. FOUNDATION WALL SHELR y;
5
— 1ST FLOOR ASSEMBLY:
l" T & G FLOOR SHEATHING,
14" DEEP OPEN WEB WOOD JOIST
EL. -1'-2
T A-402
00
:|jj=||
ii'G
ajL—MU—LM—Li
4 T.O. BASEMENT SLAB
- ___
1SS:
EL.-9-11 1/2"
t
I TT7
w
4 T.O. FOOTING =l i i=i i i=i 11= TTT TTT ” TTT
EL. -10-5 1/2
:|
— BASEMENT FLOOR ASSEMBLY:
BUILDINGSECTION
1 SCALE: 1/4" = 1'-0"
Cross Section
View =
Side view of a
cut through the
building
Detail Call Out
Indicates see Detail
4 on Sheet A-508