SlideShare a Scribd company logo
1 of 28
Download to read offline
Inverter Air Conditioning
for Light Commercial Use
Digital InverterDI
Toshiba solutions
Toshiba offers a solution for all applications: residential, light commercial and larger
commercial buildings. For small commercial premises, products are designed to
deliver top performance combined with energy efficiency.
Toshiba’s commitment to society drives a company-wide focus on attention to the
details through every stage of the development process, from design to user field
tests. Installations using our products and systems therefore feature a higher standard
of indoor air quality, sound levels, energy savings, and environmental awareness.
Superior comfort
Toshiba can help you create a comfortable space while
also caring for the environment.
3
Very efficient energy consumption, Keeps
down operating costs.
Superior EER
ECO-driving DC twin rotary compressor
Vector-controlled inverter
High efficiency heat-transfer (flat fin)
DC fan motor
Bat wing fan
Wide-flow grille
DC twin rotary compressor
Vector IPDU control changes the motor
current wave to a smooth sine pattern
so that noise emitted from the drive
units is greatly reduced.
Heat-transfer tube with improved heat-transfer
coefficient.
Highly Efficient DC Motor.
New development for high-pressure
low-volume fan.
Optimizing ventilation performance,
Bringing out the full effect of fan and motor.
A low minimum speed of 10 rps has been
achieved.
Light Commercial
The Toshiba Digital Inverter series air conditioners combine economy and ecology in a compact body. They feature state-
of-the-art technology, flexible control, and easy installation to bring natural comfort and convenience to any business
environment. Consists of Cassette and Ducted units which has excellent efficiency, not only under rated EER conditions,
but also during partial load which is the larger part of actual operating conditions.
A low minimum speed of 10 rps has been achieved.
This has further improved the operating
efficiency when the load is low
(the minimum in Series 2 was 15 rps).
Large-area magnet
Rotor with slit
High power motor
Newly designed compression path
More precise components
The structure and shape of each
compressor component has been
optimised. The area of the rotor
magnet has been increased and
a slit introduced to the design.
These improvements have further
enhanced efficiency and reduced
noise.
Operation in Power Save Mode enables power peaks to be cut.
2 HP 5 HP4 HP3 HP
3.02
3.31
2.80
5.0
4.0
3.0
2.0
1.0
0.0
(EER)
3.21
Digital Inverter / New 4-Way Cassette
Note: Actual component may vary considerably from specifications depending on product model.
An ozone layer depletion coefficient of zero has become
absolutely essential for an advanced air conditioning system.
R410A refrigerant
Fits with various size room and form
- Combination : Same type and capacity of indoor units
- Twin kit Line up
Twin split System
Quiet operation
Low-noise design. If the outdoor temperature is 30°C or less, operates at under 45 db. It’s possible to
automatically operate the quiet operation mode below 35°C air temperature.
Self-Clean operation-Continuing high performance for energy saving
This enables the 4-Way Cassette type to maintain energy efficiency.
Water
Oil/
Aqua
resin
coating
Dirt
Self-Clean Operation - The mechanism of the wash-off
1.	 The aqua resin coating prevents dirt from sticking to
the fins.
2.	 The condensation water flows and washes away dirt.
3.	 After washing, a drying operation suppresses the
propagation of mold.
4
Digital InverterDI
Extremely lightweight and compact outdoor unit
Lighter than the current model by 8 kg (11%)
4 HP
5 HP
1104ATP-E
1404ATP-E
-8kg68kg
previous model:76kg
Small compact size chassis
Reduces installation spaces and enables a more efficient use of the site.
Easy to install the outdoor units on a double-decked and easy to install on a wall.
Current model
New model
Wide-Utility function
Heating operation is possible starting from an outdoor temperature of -20°C, while cooling operation is
possible at -15°C and up to 46 outdoor temperature. This enables wider applications and use of the system
in colder regions.
Outstandingly quiet operation & save operation setting
Night operation make it possible to suppress the operation sound of the
outdoor unit within the time which you desire. (12dB(A) reduction)*
Easy and safty operation for maintenance of the outdoor unit.
Inspection window makes it easy to find switch that requires operation and reduces the risk of electrical shock.
Remarkable energy efficiency
Industry’s top-class energy-saving
2,3 HP 4,5 HP
(Max.10%UP)
Cover
Inspection window
Maintenance Switch (2 tact switches)
Maintenance light (6LED)
Save operation setting is available from 50% to 100% by 1%
Quiet operation & save operation setting available for 2HP, 3HP, 4HP and 5HP
*5HP Outdoor unit, Heating.
Note: Night operation - Necessity to set the Lite-vision plus remote controller (RBC-AMS51E)
Save operation - Necessity to set the Lite-vision plus remote controller (RBC-AMS51E), RBC-AMT32E
55
DIBIG
DI Big proposes competitive cost systems solution for medium size applications like Shops and Small Office buildings.
Simultaneous operation of 2, 3 or up to 4 indoor unit can be installed as twin, triple and double twin systems with
single outdoor unit.
Compact outdoor unit
Small footprint in only 0.29 m2, Compact design in size (W 900mmx D 320mm) allows opportunity for
more space saving.
High efficiency EER/COP* performance
DI Big is equipped with a new twin-rotary DC inverter compressor with high efficiency R410A refrigerant.
A new technology twin-rotary DC compressor, 100W +100W output Highly-efficient DC fan motor,
propeller fan for newly developed 3-row heat exchanger.
EER / COP = 2.81 / 3.61 ( With 4-way cassette twin system of 10HP)
Wider discharge port for less pressure loss
Screw connection for larger current
Decreasing oil discharge for reliability
Larger displacement cylinder (55cm3/rev)
Expanded operating temperature range
Air conditioning system designing is easy with DI-BIG because of its expanded operation range.
Heater operation is possible starting from an outdoor temperature of -20°C, while cooling operation
is possible at -15°C and up to 46 outdoor temperature.
This enables wider applications and use of the system in colder regions.
DI BIG
Outdoor temp. range when cooling* -15˚C to 46˚C
Outdoor temp. range when heating* -20˚C to 15˚C
Heating operation range
15˚C0˚C-15˚C-20˚C
*Cooling : ˚CDB, Heating: ˚CWB
DI BIGDI BIG
Compatible with pipes up to 70 meters long with
a maximum height difference of 30 meters height
6
Equivalent HP 2HP 3HP 4HP 5HP 6HP
Standard model (RAV-) SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E
Heavy Anti-Corrosion protection model (RAV-) SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E
4-Way Cassette type
Single (RAV-) SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E N/A
Twin (RAV-) N/A N/A SM564UTP-E x 2 SM804UTP-E x 2 SM804UTP-E x 2
Triple (RAV-) N/A N/A N/A N/A SM564UTP-E x 3
Standard Duct type
Single (RAV-) SM566BTP-E* SM806BTP-E* SM1106BTP-E* SM1406BTP-E* N/A
Twin (RAV-) N/A N/A SM566BTP-E* x 2 SM806BTP-E* x 2 SM806BTP-E* x 2
Triple (RAV-) N/A N/A N/A N/A SM566BTP-E* x 3
Concealed Duct High Static Pressure type
Single (RAV-) N/A N/A N/A N/A SM1603DT-A
Twin (RAV-) N/A N/A N/A N/A N/A
Triple (RAV-) N/A N/A N/A N/A N/A
Digital Inverter 1-phase model
*1	 Rated conditions Cooling : Indoor air temperature 27o
C DB / 19o
C WB, Outdoor air temperature 35o
C DB
Heating : Indoor air temperature 20o
C DB, Outdoor air temperature 7o
C DB / 6o
C WB
*2	 Sound pressure levels measured in an anechoic chamber
77
Equivalent HP 10HP
50Hz
Standard model (RAV-) SM2804AT8-E
Heavy Anti-Corrosion protection model (RAV-) SM2804AT8ZG-E
4-Way Cassette type
Single (RAV-) N/A
Twin (RAV-) SM1404UTP-E x 2
Triple (RAV-) SM804UTP-E x 3
Double twin
(RAV-)
SM804UTP-E x 4
Standard Duct type
Single (RAV-) N/A
Twin (RAV-) SM1406BTP-E* x 2
Triple (RAV-) SM806BTP-E* x 3
Double twin
(RAV-)
SM806BTP-E* x 4
Concealed Duct High Static Pressure type
Single (RAV-) SM2802DT-E
Twin (RAV-) N/A
Triple (RAV-) N/A
Double twin
(RAV-)
N/A
Digital Inverter Big 3-phase model
*1	 Rated conditions Cooling : Indoor air temperature 27o
C DB / 19o
C WB, Outdoor air temperature 35o
C DB
Heating : Indoor air temperature 20o
C DB, Outdoor air temperature 7o
C DB / 6o
C WB
*2	 Sound pressure levels measured in an anechoic chamber
8
rAV-SM∗∗∗4UTP-E
4-Way Cassette type
RBC-U31PGP(W)-E
The wide air flow in all direction
Multi-louver individual control
Individual louver control enables airflow to be chosen according to user preferences.
The angles of each louver can be set individually in 3 different choices of swing
patterns; Standard swing, Diagonally opposite swing and Turn-around swing
(1) Standard swing (2) Diagonally opposite swing (3) Turn-around swing
New Long-life pre-filter
A new long-life pre-filter has a surface 1.5 times of current filters to improve Dust-collection performance.
Built-in condensate drain pump Easy installation
Light weight unit (24kg at 5HP) Easy panel
installation, The panel is attached using the
bolt that is already installed on the indoor unit.
300mm or less
850mm or less
210mm
Panel
Wide flow louver type
4-Way Cassette type
Digital Inverter
.
Comfort
Inverter
Allows step-less regulation of the
air-conditioner’s power,which reduces
energy consumption and improves
comfort.
.
Individual Louvre control
Enables airflows to be chosen
according to user preferences.
.
Hot Start
When using the heater for preheating
or defrosting, stops the indoor fan to
prevent cold air from being blown into
the room.
Dry
Gradually dehumidifies the room to
create even greater comfort.
Operativity
Filter Sign
Automatic displays on the remote
controller say when to perform
maintenance for the indoor unit filter.
Limit Timer
Uses a 168-hour timer with three
modes - “ON timer”, “OFF timer” and
“Repeat OFF timer”.
Installation
Cooler Compatible with an Outdoor
Temperature of -15 ° C
Stable cooler operation is possible
when the outdoor temperature is as
low as -15 ° C.
Built-in Drain Pump
The built-in drain pump makes
draining easier. (In the ceiling cassette
type, it is built in to the main unit.)
Long-life Filter
Built-in long-life filter makes
maintenance easier.
Automatic Air Volume control
Depending on the difference between
the room temperature and the set
temperature, switches automatically
between High, Low and Very Low.
Auto-turn Louvre
Air outlet grilles move automatically
to fill every corner of the room with
warm or cool air.
*European market only
99
Physical data Indoor unit (RAV-) SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E
Standard air flow (H/M/L) CFM 617/512/459 723/564/476 1182/847/688 1235/847/723
Sound pressure level (H/M/L) dB(A) 32/29/28 35/31/28 43/38/33 44/38/34
Main unit dimensions (H/W/D) mm 256/840/840 256/840/840 319/840/840 319/840/840
Weightkg 20 20 24 24
Panel dimensions (H/W/D) mm 30/950/950 30/950/950 30/950/950 30/950/950
Panel weight kg 4.2 4.2 4.2 4.2
Physical data Outdoor Unit Equivalent HP 2HP 3HP 4HP 5HP
Out
door
unit
Standard model (RAV-) SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E
Heavy Anti-Corrosion protection model (RAV-) SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E
Power supply 1-phase 50Hz 230V (220–240V)
Compressor type DC twin rotary
Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5
Standard / Min. pipe length m 7.5 / 5 7.5 / 5 7.5 / 5 7.5 / 5
Max. pipe total length m 30 30 50 50
Maximum height difference m 30 30 30 30
Outer dimensions (H/W/D) mm 550/780/290 550/780/290 890/900/320 890/900/320
Weight kg 40 44 68 68
Sound pressure level, Cooling/Heating*2 dB(A) 46/48 48/52 53/54 54/55
Operating range, Cooling/Heating °C -15~46 / -15~15
Out
door
unit
Standard model (RAV-) SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E
Heavy Anti-Corrosion protection model (RAV-) SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E
Indoor unit (RAV-) SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E
Cooling*1
Capacity kW 5.0 6.7 10.0 12.0
Range, min-max kW 1.5-5.6 1.5-8.0 3.0-11.2 3.0-13.2
Power consumption kW 1.56 2.22 3.02 4.29
EER (Energy
Efficiency Ratio)
Capacity 100% 3.21 3.02 3.31 2.80
Capacity 80% 4.00 3.77 4.08 3.53
Capacity 50% 5.21 5.49 5.10 5.00
Heating*1
Capacity kW 5.3 7.7 11.2 12.8
Range, min-max kW 1.5-6.3 1.5-9.0 3.0-13.0 3.0-16.0
Power consumption kW 1.36 2.13 2.93 3.40
COP (Coefficient of
Performance)
Capacity 100% 3.90 3.62 3.82 3.76
Capacity 80% 4.37 4.22 4.23 4.30
Capacity 50% 5.41 5.50 5.19 5.12
Power supply 1-phase 50Hz 230V (220–240V)
Performance dataDI-Digital Inverter
10
RAV-SM***4UTP-E
155
28.5
61
5764
187
32
Celling
bottom
surface
Knockoutfor
fresh airintake φ100
Z view
300orless
Stand-up
661orless
Stand-up850orless
Bottom faceofceiling Drain standing-up size
A
B
860to 910Ceiling open dim ension
860to910Ceilingopendimension
1000orm ore 1000orm ore
15or
more
15or
more
1000or
more
Space required forinstallation and servicing
Z
SM564UTP-E
SM1104UTP-E, SM1404UTP-E
AModel RAV-
256
319
74
137
B
(Unit:mm)
C D
12.7
15.9
6.4
9.5
SM804UTP-E 256 74
C D
15.9 9.5
Options
Packing A
Air discharge
parts A
Refrigerant
piping
side
Drain piping
side
Packing B
Packing B
Air discharge
parts B
Air discharge
parts C
Air inlet grille
Ceiling panel
Fresh air inlet box
Air discharge direction kit
Spacer for height adjustment
Spacer for height adjustment
RBC-U31PGP(W)-E
RBC-U31PGP(WS)-E
TCB-SP1602UE
TCB-GB1602UE
TCB-GFC1602UE
TCB-FF101URE2
TCB-BC1602UE
Bottom face of Ceiling
1000 or more1000 or more
1000or
more
15or
more
860to910Ceilingopendimension
Ceiling
Electric
parts box
Ceiling
860 to 910 Ceiling open dimension
Space required for installation and servicing
bottom
surface
Knockout for
fresh air intake
Drain standing-up size
Z view
300 or less
Stand-up850orless
Stand-up
661orless
15or
more
Hanging bolt M10 or
Ceiling panel
(sold separately)
of ceiling
Bottom face
For branch duct Knockout
square hole
(procured by locally)
Hanging bolt pitch
Panel external dimension
Panelexternaldimension
Hangingboltpitch
Bottomface
ofceiling
Take-inport
ofwiring
Drainpipe
connectionport
squarehole
(Material:PP)
Refrigerantpipe
connectingport
(Liquidside)
(Gaside)
Refrigerantpipe
connectingport
ForbranchductKnockout
1111
Compact sizing
Compact size especially in height (275 mm), new slimmer chassis offers wide range of
installation opportunities to customer.
Standard Duct type
rav-sm∗∗∗6Btp-E*
Wide range of application opportunities
High static pressure
External static pressure can be raised as high as 120 Pa, so that all areas of the room
can be reached for even temperature distribution, no matter how complex the layout.
275mm
275mm
Built-in High-lift drain pump#
The flexible piping layout is made possible by an optionally available drain-pump kit
that raises the drain piping up to 29 cm from the drain port.
Flexible duct is accessible, Allows complete design flexibility
Polygonal rooms Narrow rooms Rooms with fixtures
and obstacles
New spigot shaped flange as new accessories
New spigot shaped flange has higher static pressure with optimized
design, the static pressure drops only 20Pa from rectangle flange states.
Maximum Static pressure will be 100Pa* with all models.
(*static pressure with filter which included in, and intake from back ward)
.
.
Comfort
Inverter
Allows step-less regulation of the
air-conditioner’s power,which reduces
energy consumption and improves
comfort.
.
Hot Start
When using the heater for preheating
or defrosting, stops the indoor fan to
prevent cold air from being blown into
the room.
Dry
Gradually dehumidifies the room to
create even greater comfort.
Operativity
Filter Sign
Automatic displays on the remote
controller say when to perform
maintenance for the indoor unit filter.
Limit Timer
Uses a 168-hour timer with three
modes - “ON timer”, “OFF timer” and
“Repeat OFF timer”.
Installation
Cooler Compatible with an Outdoor
Temperature of -15 ° C
Stable cooler operation is possible
when the outdoor temperature is as
low as -15 ° C.
Built-in Drain Pump
The built-in drain pump makes
draining easier. (In the ceiling cassette
type, it is built in to the main unit.)
Long-life Filter
Built-in long-life filter makes
maintenance easier.
Automatic Air Volume control
Depending on the difference between
the room temperature and the set
temperature, switches automatically
between High, Low and Very Low.
Standard Duct type
Digital Inverter
Spigot shaped flange
TCB-SF56C6BEP
TCB-SF80C6BEP
TCB-SF160C6BEP
#Not available with 6HP and 10HPhigh static duct IDU
12
Physical data Equivalent HP 2HP 3HP 4HP 5HP 6HP
Out
door
unit
Standard model
(RAV-)
SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E
Heavy Anti-Corrosion protection model
(RAV-)
SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E
Power supply 1-phase 50Hz 230V (220–240V) 1-phase 50Hz 230V (220–240V)
Compressor type DC twin rotary
Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø15.9 / ø9.5
Standard / Min. pipe length m 7.5 / 5
Max. pipe total length m 30 50
Maximum height difference m 30 30 30
Outer dimensions (H/W/D) mm 550/780/290 890/900/320 1340/900/320
Weight kg 40 44 68 99
Sound pressure level, Cooling/Heating*2
 dB(A) 46/48 48/52 53/54 54/55 51/53
Operating range, Cooling/Heating °C -15~46 / -15~15 -15~43 / -15~15
Physical data Indoor unit (RAV-)
SM406BT-E,
SM406BTP-E*
SM456BT-E,
SM456BTP-E*
SM566BT-E,
SM566BTP-E*
SM806BT-E,
SM806BTP-E*
SM1106BT-E,
SM1106BTP-E*
SM1406BT-E,
SM1406BTP-E*
SM1603DT-A
Standard air flow (H/M/L) CFM 469/370/282 469/370/282 469/370/282 706/547/423 1235/970/741 1235/970/741 2047
External static pressure (factory setting) Pa 30 30 30 30 50 50 100
External static pressure-Standard (Upper-Lower) Pa 30(120-30) 30(120-30) 50(120-30) 100(50-250)
Sound pressure level (H/M/L) dB(A) 33/29/25 33/29/25 33/29/25 34/30/26 40/36/33 40/36/33 50
Dimensions (H/W/D) mm 275/700/750 275/700/750 275/700/750 275/1000/750 275/1400/750 275/1400/750 380/1050/600
Weightkg 23 23 23 30 40 40 57
Out
door
unit
Standard model (RAV-) SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E
Heavy Anti-Corrosion protection model (RAV-) SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E
Indoor unit (RAV-)
SM566BT-E,
SM566BTP-E*
SM806BT-E,
SM806BTP-E*
SM1106BT-E, SM1106BTP-E*
SM1406BT-E,
SM1406BTP-E*
SM1603DT-A
Cooling*1
Capacity kW 5.0 6.7 10.0 12.1 14.3
Range, min-max kW 1.5-5.6 1.5-7.4 3.0-11.2 3.0-13.2 3.6-16.0
Power consumption kW 1.83 2.38 3.14 4.42 5.01
EER (Energy
Efficiency Ratio)
Capacity 100% 2.73 2.82 3.18 2.74 2.85
Capacity 80% 3.42 3.53 3.92 3.46 3.35
Capacity 50% 4.39 5.08 4.90 4.92 4.09
Heating*1
Capacity kW 5.3 7.7 11.2 12.8 16.0
Range, min-max kW 1.5-6.3 1.5-9.0 3.0-12.5 3.0-16.0 4.6-18.0
Power consumption kW 1.62 2.32 2.99 3.55 4.57
COP (Coefficient
of Performance)
Capacity 100% 3.27 3.32 3.75 3.61 3.50
Capacity 80% 3.69 3.87 4.15 4.11 3.68
Capacity 50% 4.57 5.07 5.09 4.89 3.91
Power supply 1-phase 50Hz 230V (220–240V) 1-phase 50Hz 230V (220–240V)
Performance dataDI-Digital Inverter Performance data
1313
RAV-SM***6BT(P)*-E
Options
SM566BT(P)*-E
SM806BT(P)*-E
SM1106BT(P)*-E, SM1406BT(P)*-E
Model RAV-
765
1065
700
1000
1400
640
940
1340
750
1050
1450
A B DC
345
355
108
37
232
Refrigerant pipe
connecting port
(Liquid side)
Refrigerant pipe
connecting port
(Gas side)
Air outlet
Ceiling
Service door (Ceiling opening)
Floor surface
25 25
D
100 or
more
700
or more
2500
ormore
275
5or
more
117.5
233
18
Drain pipe
connecting port
23320570
20
s
t
70or
more
A
B
C
D
E
E
1465
700
500
700
(Unit:mm)
F G
F
G
12.7
15.9
6.4
9.5
12.7 6.4
Space required for installation and servicing
TCB-SF56C6BE
TCB-SF80C6BE
TCB-SF160C6BE
Model
SM566BT(P)*-E
SM806BT(P)*-E
Compatible
SM1106BT(P)*-E, SM1406BT(P)*-E
TCB-SF56C6BE TCB-SF80C6BE
TCB-SF160C6BE
(Unit:mm)
TCB-SF56C6BE
TCB-SF80C6BE
TCB-SF160C6BE
Hanging bolt pitch
Unit external dimension
External dimensions of flange
A
B
C
E
1/100 or more downward
At the time of natural drainage
Under air intake type
Flexible drain hose
(Accessory)
Wires
drawing-out port
650
14
(Unit: mm)
20
10296
316
15
25
10
2525
20
60
276
(Inside)
274
(Inside)
757 (Inside) 845 (Inside)5252 0202
12
65 65
12 25 67.5 250 250
885
11 × 65 = 715
250 67.5
15
652652 271
807
11 × 65 = 715
4×60=240
300
324
15
25
60
4×60=240
10-Ø5 hole
(Include in the other side)
24-Ø5 hole
(Include in the other side)
24-Ø5 hole
(Include in the other side)
8-Ø7 hole
10-Ø5 hole
(Include in the other side)8-Ø7 hole
Flange (Air outlet side) Flange (Air inlet side)
Plug
(Port for check
and clean)
Drain pipe
Adhesive inhibited
Check port
400 × 800
50
ormore
100
ormore1300ormore
200
200
ormore
Service work space
Drain trap
704
12
32
52
30
50
950(Boltpitch)(50)(50)
(900)(95)
1050
965(Boltpitch)(35)(50)
(36)
(53)
(72)(915)
664
25
48490
25 (111) 854 (85)
14514520
(30)
975042
380
271(28)81
600
2)006 5 () 25 (
wo l f r i Awo l f r i A
Hung-up plate
Refrigerant piping (5/8” (Ø15.88))
Refrigerant piping (3/8” (Ø9.52))
Refrigerant piping (3/8” (Ø9.52))
3-M5 hole for drain pump kit
Refrigerant piping (5/8” (Ø15.88))
Drain port (Outer diameter: Ø32)
Electric parts box Drain port (Outer diameter: Ø32)
RAV-SM 1403DT-A, RAV-SM 1603DT-A
(Unit: mm)
20
10296
316
15
25
10
2525
20
60
276
(Inside)
274
(Inside)
757 (Inside) 845 (Inside)5252 0202
12
65 65
12 25 67.5 250 250
885
11 × 65 = 715
250 67.5
15
652652 271
807
11 × 65 = 715
4×60=240
300
324
15
25
60
4×60=240
10-Ø5 hole
(Include in the other side)
24-Ø5 hole
(Include in the other side)
24-Ø5 hole
(Include in the other side)
8-Ø7 hole
10-Ø5 hole
(Include in the other side)8-Ø7 hole
Flange (Air outlet side) Flange (Air inlet side)
Plug
(Port for check
and clean)
Drain pipe
Adhesive inhibited
Check port
400 × 800
50
ormore
100
ormore1300ormore
200
200
ormoreService work space
Drain trap
704
12
32
52
30
50
950(Boltpitch)(50)(50)
(900)(95)
1050
965(Boltpitch)(35)(50)
(36)
(53)
(72)(915)
664
25
48490
25 (111) 854 (85)
14514520
(30)
975042
380
271(28)81
600
2)006 5 () 25 (
wo l f r i Awo l f r i A
Hung-up plate
Refrigerant piping (5/8” (Ø15.88))
Refrigerant piping (3/8” (Ø9.52))
Refrigerant piping (3/8” (Ø9.52))
3-M5 hole for drain pump kit
Refrigerant piping (5/8” (Ø15.88))
Drain port (Outer diameter: Ø32)
Electric parts box Drain port (Outer diameter: Ø32)
RAV-SM 1403DT-A, RAV-SM 1603DT-A
1515
rav-sm∗∗∗2dt-E
Design flexibility
Compatible with external static pressures up to 196 Pa.
Concealed Duct High Static Pressure type
Satisfies all your design needs
Concealed Duct High Static Pressure type
DI BIG
.
Comfort
Inverter
Allows step-less regulation of the
air-conditioner’s power,which reduces
energy consumption and improves
comfort.
.
Automatic Air Volume control
Depending on the difference between
the room temperature and the set
temperature, switches automatically
between High, Low and Very Low.
.
Hot Start
When using the heater for preheating
or defrosting, stops the indoor fan to
prevent cold air from being blown into
the room.
Operativity
Filter Sign
Automatic displays on the remote
controller say when to perform
maintenance for the indoor unit filter.
Limit Timer
Uses a 168-hour timer with three
modes - “ON timer”, “OFF timer” and
“Repeat OFF timer”.
Installation
Cooler Compatible with an Outdoor
Temperature of -15 ° C
Stable cooler operation is possible
when the outdoor temperature is as
low as -15 ° C.
3-steps-switchable static pressure
Large air volume, Duct high static pressure type is most
suitable for the large rooms. Long-life filters fitted as standard.
Can be equipped with the following options:
• high-efficiency filter (65, 90)
• drain pump kit (optional)
Low Middle High
External static pressure (Pa) 68.6 137.0 196.0
Construction characteristics
The flexible duct is accessible.
Constant temperature setting is possible in large rooms or factories.
Easy service and installation.
Enable to maintain the blower section from unit side for maintenance and repair.
Enable to select auto restart operation (set from wired remote controller)
*Factory setting : 137Pa
Dry
Gradually dehumidifies the room to
create even greater comfort.
16
MML-AP***4NH-EOutdoor unit (RAV-) SM2804AT8-E
Indoor unit (RAV-) SM2802DT-E
Cooling*1
Capacity kW 23.0
Range, min-max kW 9.8-27.0
Power consumption kW 8.75
EER
(Energy Efficiency Ratio)
Capacity 100% 2.63
Capacity 80% 3.24
Capacity 50% 4.49
Heating*1
Capacity kW 27.0
Range, min-max kW 9.8-31.5
Power consumption kW 8.15
COP
(Coefficient of
Performance)
Capacity 100% 3.31
Capacity 80% 3.80
Capacity 50% 4.77
Power supply 3-phase 50Hz 380– 415V
DI BIG Performance data
Physical data Indoor unit (RAV-) SM2802DT-E
Standard air flow at 137Pa/ (at Mid tap) CFM 2470
External static pressure (H/M/L) Pa 196/137/68.6
Sound pressure level (H/M/L) dB(A) 55
Dimensions (H/W/D) mm 470/1380/1250
Weightkg 160
Physical data Equivalent HP 10HP
Outdoor unit (RAV-) SM2804AT8-E
Power supply 3-phase 50Hz 380– 415V
Compressor type DC twin rotary
Connecting pipe dia., Gas/Liquid side mm ø28.6 / ø12.7
Min. pipe length m 7.5
Max. pipe total length m 70
Maximum height difference m 30
Outer dimensions (H/W/D) mm 1540/900/320
Weight kg 134
Sound pressure level, Cooling/Heating*2
 dB(A) 57/58
Operating range, Cooling/Heating °C -15~46 / -20~15
RAV-SM***2DT-E
Filter chamber
TCB-FCY100DE
TCB-PF3DE
Drain pump kit
TCB-DP32DE
TCB-UFM3DE
TCB-UFH7DE
Options
(4-12 × 92)
600
1288
1328
624
698
1250
250
37065
250
35
250
22
46
250
002051
31
200
250
3540629
470
45
250 250 250
1260
1380100
65
1000
200
190
190
Space required for installation and serving
Hole for hanging bolt
Service space
Refrigerant pipe connecting port
(Gas side Brazed)
ormore
*
Check port
Service space
Service space
(Hanging bolt mounting pitch)
(Hangingboltmountingpitch)
Air discharge port
Screw hole for duct mounting (10-M6)
Air suction port
Refrigerant pipe connecting port
(Liquid side 12.7 Flared)*
Drain pipe connecting port (V25)
Taper screw for R1,25.4 pipes
Electric parts box
Power supply/communication piping
port (Ø26) (Under electric parts box)
Screw hole for duct mounting (10-M6)
(Unit:mm)
ormore
(Unit:mm)
22.2 12.7
Diameter of pipe connecting port Diameter of pipe connecting pipe
Gas sideLiquid side Gas sideLiquid side
12.7 28.6
1717
18
Indoor unit type
Outdoor unit name
(RAV-)
Indoor unit name
(RAV-)
HP
Capacity EER
Rated
(kW)
min-max
(kW)
Power consumption
(kW)
100% 80% 50%
4-Way Cassette
SM1104AT(J)P-E SM564UTP-E 4 10.0 3.0-11.2 3.02 3.31 4.08 5.10
SM1404AT(J)P-E SM804UTP-E 5 12.0 3.0-13.2 4.29 2.80 3.53 5.00
SM1603AT(Z)(ZG)-E SM804UTP-E 6 14.0 3.0-16.0 4.49 3.12 3.98 4.86
Standard Duct
SM1104AT(J)P-E SM566BTP-E* 4 10.0 3.0-11.2 3.14 3.18 3.92 4.90
SM1404AT(J)P-E SM806BTP-E* 5 12.1 3.0-13.2 4.42 2.74 3.46 4.92
SM1603AT(Z)(ZG)-E SM806BTP-E* 6 14.0 3.0-16.0 5.13 2.73 3.48 4.24
Twin system : DI-Digital Inverter 1-phase
Indoor unit type
Outdoor unit name
(RAV-)
Indoor unit name
(RAV-)
HP
Capacity COP
Rated
(kW)
min-max
(kW)
Power consumption
(kW)
100% 80% 50%
4-Way Cassette
SM1104AT(J)P-E SM564UTP-E 4 11.2 3.0-13.0 2.93 3.82 4.23 5.19
SM1404AT(J)P-E SM804UTP-E 5 12.8 3.0-16.0 3.40 3.76 4.30 5.12
SM1603AT(Z)(ZG)-E SM804UTP-E 6 16.0 3.0-18.0 4.43 3.61 4.59 4.91
Standard Duct
SM1104AT(J)P-E SM566BTP-E* 4 11.2 3.0-12.5 2.99 3.75 4.15 5.09
SM1404AT(J)P-E SM806BTP-E* 5 12.8 3.0-16.0 3.55 3.61 4.11 4.89
SM1603AT(Z)(ZG)-E SM806BTP-E* 6 16.0 3.0-18.0 4.69 3.41 4.04 4.32
Twin system : DI-Digital Inverter 1-phase
Cooling
Heating
Indoor unit type
Outdoor unit name
(RAV-)
Indoor unit name
(RAV-)
HP
Capacity EER
Rated
(kW)
min-max
(kW)
Power consumption
(kW)
100% 80% 50%
4-Way Cassette SM2804AT8(Z)(ZG)-E SM1404UTP-E 10 23.0 9.8-27.0 8.19 2.81 3.46 4.79
Standard Duct SM2804AT8(Z)(ZG)-E SM1406BTP-E* 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62
Twin system : DI Big 3-phase
Indoor unit type
Outdoor unit name
(RAV-)
Indoor unit name
(RAV-)
HP
Capacity COP
Rated
(kW)
min-max
(kW)
Power consumption
(kW)
100% 80% 50%
4-Way Cassette SM2804AT8(Z)(ZG)-E SM1404UTP-E 10 27.0 9.8-31.5 7.48 3.61 4.15 5.21
Standard Duct SM2804AT8(Z)(ZG)-E SM1406BTP-E* 10 27.0 9.8-31.5 7.92 3.41 3.91 4.91
Twin system : DI Big 3-phase
Cooling
Heating
Twin, Triple and Double twin system
1919
Twin, Triple and Double twin system
Indoor unit type
Outdoor unit name
(RAV-)
Indoor unit name
(RAV-)
HP
Capacity COP
Rated
(kW)
min-max
(kW)
Power consumption
(kW)
100% 80% 50%
4-Way Cassette SM2804AT8(ZG)-E SM804UTP-E 10 27.0 9.8-31.5 7.48 3.61 4.15 5.21
Standard Duct SM2804AT8(ZG)-E SM806BTP-E 10 27.0 9.8-31.5 7.92 3.41 3.91 4.91
Triple system : DI Big 3-phase Heating
Indoor unit type
Outdoor unit name
(RAV-)
Indoor unit name
(RAV-)
HP
Capacity EER
Rated
(kW)
min-max
(kW)
Power consumption
(kW)
100% 80% 50%
4-Way Cassette SM2804AT8(ZG)-E SM804UTP-E 10 23.0 9.8-27.0 8.19 2.81 3.46 4.79
Standard Duct SM2804AT8(ZG)-E SM806BTP-E 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62
Triple system : DI Big 3-phase Cooling
Indoor unit type
Outdoor unit name
(RAV-)
Indoor unit name
(RAV-)
HP
Capacity COP
Rated
(kW)
min-max
(kW)
Power consumption
(kW)
100% 80% 50%
4-Way Cassette SM1603AT(Z)(ZG)-E SM564UTP-E 6 16.0 3.0-18.0 4.43 3.61 4.59 4.91
Standard Duct SM1603AT(Z)(ZG)-E SM566BTP-E* 6 16.0 3.0-18.0 4.69 3.41 4.04 4.32
Triple system : DI-Digital Inverter 1-phase Heating
Indoor unit type
Outdoor unit name
(RAV-)
Indoor unit name
(RAV-)
HP
Capacity EER
Rated
(kW)
min-max
(kW)
Power consumption
(kW)
100% 80% 50%
4-Way Cassette SM1603AT(Z)(ZG)-E SM564UTP-E 6 14.0 3.0-16.0 4.49 3.12 3.98 4.86
Standard Duct SM1603AT(Z)(ZG)-E SM566BTP-E* 6 14.0 3.0-16.0 5.13 2.73 3.48 4.24
Triple system : DI-Digital Inverter 1-phase Cooling
Indoor unit type
Outdoor unit name
(RAV-)
Indoor unit name
(RAV-)
HP
Capacity EER
Rated
(kW)
min-max
(kW)
Power consumption
(kW)
100% 80% 50%
4-Way Cassette SM2804AT8(ZG)-E SM804UTP-E 10 23.0 9.8-27.0 8.19 2.81 3.46 4.79
Standard Duct SM2804AT8(ZG)-E SM566BTP-E* 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62
Double twin system : DI Big 3-phase Cooling
Indoor unit type
Outdoor unit name
(RAV-)
Indoor unit name
(RAV-)
HP
Capacity COP
Rated
(kW)
min-max
(kW)
Power consumption
(kW)
100% 80% 50%
4-Way Cassette SM2804AT8(ZG)-E SM804UTP-E 10 27.0 9.8-31.5 7.48 3.61 4.15 5.21
Standard Duct SM2804AT8(ZG)-E SM566BTP-E* 10 27.0 9.8-31.5 7.92 3.41 3.91 4.91
Double twin system : DI Big 3-phase Heating
20
Indoor unit Parts Name Model Name Applied Model Remarks
4-Way Cassette type
Ceiling panel
RBC-U31PGP(W)-E,
RBC-U31PGP(WS)-E
RAV-SM***4UTP-E
Fresh air inlet box TCB-GB1602UE Use with TCB-GFC1602UE
Fresh air filter chamber TCB-GFC1602UE
Auxiliary fresh air flange TCB-FF101URE2
Spacer for height adjustment TCB-SP1602UE
Air discharge direction kit TCB-BC1602UE
Standard Duct type Spigot shaped flange
TCB-SF80C6BE RAV-SM806BTP-E*
TCB-SF160C6BE RAV-SM1106BTP-E* RAV-SM1406BTP-E*
Concealed Duct High Static
Pressure type
High-efficiency filter 65 TCB-UFM3DE
RAV-SM***2DT-E
Use with TCB-FCY100DEHigh-efficiency filter 90 TCB-UFH7DE
Long life prefilter TCB-PF3DE
Filter chamber TCB-FCY100DE
Drain pump kit TCB-DP32DE
Indoor unit accessories
Parts Name Model Name Type
Branch kit
RBC-TWP30E
Digital Inverter 1-phase model
RBC-TWP50E
RBC-TWP101E 1:2 Twin system of Dl Big model
RBC-TRP100E 1:3 Digital Inverter 1-phase model and DI Big model
RBC-DTWP101E 1:4 Double twin system of DI Big model
Digital Inverter - Controllers  Accessories
Parts Name Model Name Applied Model Features
Wired remote controller
RBC-AMT32E All indoor units Standard type
RBC-AMS41E All indoor units Remote controller with weekly timer
RBC-AMS51E-ES/-EN All indoor units Remote controller with LCD display with backlight
Simple wired remote controller RBC-AS41E All indoor units With Simplified control
Wireless remote controller kits
RBC-AX32U(W)/(WS)-E 4-Way Cassette type Integral receiver type
TCB-AX32E2 All indoor units Standalone receiver type
Remote controller kits
TCB-EXS21TLE Use with wired remote controller Remote controller with schedule timer
TCB-CC163TLE2
Used with wired remote controller / Central remote
controller
On-Off controller combined with the weekly timer
TCB-SC642TLE2 All indoor units Central remote controller
BMS-CM1280TLE All indoor units Compliant manager
TCC-Link* TCB-PCNT30TLE2 All indoor units except High-wall type Use with Remote controller kit
Indoor unit controllers
* : TCC-Link Adaptor for Digital Inverter units.
2121
Standard Remote controller
RBC-AMT32E
Standard wired remote controller can be connected to a single indoor unit
or a group of up to 8 indoor units. Power save operation limits the greatest
current value.The remote controller allows error to be displayed
while the protective device works or a error occurs.
Remote controller with weekly timer
(7-day timer function)
RBC-AMS41E
Wired remote controller with clock display and a built in 7-day timer function,
possible to program 8 functions for each day of the week.
*The following items can be set in program: operation time,
operation start/stop, operation mode, temperature setting,
restriction on button operation
Lite-Vision plus Remote Controller
RBC-AMS51E-ES
RBC-AMS51E-EN
Wired remote controller with a built in 7-day timer-featuring a new multi-language,
LCD display with backlight, energy saving options and a return back function.
• Possibility to set and display the room name to easily set-up and monitor the working parameter.
• New modern and desirable controller design with menu driven display.
• Save mode by schedule timer to optimise energy consumption.
• Room temperature display always available.
• Two“Hot Keys”(F1, F2) for easy operation of air conditioner functions.
• Easy to read layout including display of indoor unit model name and serial number.
• Built-in backup power. Settings are kept in memory up to 72 hours in case of power failure.
• Remote TA sensor available in controller.
• Can be connected to a single indoor unit or a group of up to 8 indoor units.
Simple wired remote controller can be connected to a
single indoor unit or a group of up to 8 indoor units.
• Start/Stop
• Temperature setting
• Air flow changing
• Check code display
Simple wired remote controller
RBC-AS41E
Wireless remote controller kit
• Start/Stop •Changing mode •Temperature setting
• Air flow changing
• Timer function Either“ON”time or“OFF”time or
“CYCLIC”can be set how many 30 min. later ON or OFF
is operated.
• Control by 2 remote controllers is available.
Two wireless remote controllers can operate
one indoor unit. The indoor unit can then be
operated separately from the two different locations.
• Check code display
RBC-AX32U(W)/(WS)-E
Integral receiver
(For 4-way cassette)
TCB-AX32E2
Sensor unit; Stand alone receiver
(For 4-way cassette), (Duct type)
Schedule timer
TCB-EXS21TLE
Central remote
controller
BMS-CM1280TLE
• Schedule timer mode
– 6 programmings per day
– Enabling 8 groups to be programmed
– A maximum of 64 indoor units can be controlled
– A maximum of 100 hours back-up power supply
• Weekly timer mode
– 7 types of weekly schedule and 3 programmings
per day
ON-OFF controller
TCB-CC163TLE2
• Individual control of up to 16 indoor units.
• Setting of simultaneous ON/OFF 3 times per
day combined with the weekly timer.
Central remote controller
TCB-SC642TLE2
• Individual control for max. 64 indoor units divided
into 1 to 4 zone (Up to 16 indoor units for each zone)
• Up to 16 outdoor header units are connectable
• 4 types of central control settings to inhibit individual
operation by remote controller can be selected
• Usable with other central control devices
(Max. 10 devices in one control circuit)
• Two control mode selectivity
(Central controller mode ) Remote controller mode
• Setting of simultaneous ON/OFF 3 times per day
combined with the weekly timer.
• Operation
Individual operation of 128 indoor units available
Return Back Operation
Weekly Schedule Operation*
(ON/OFF)
* Schedule timer necessary
• Monitoring
Zone setting (64 zones x 2)
Individual unit operation mode operation restriction
Alarm display
Control input
Status output
Remote controllers
22
Discharge guide mounting hole
(4-dia.4.5 embossing)
charge port Earth terminal
Discharge guard
B legs
A legs
Drain hole
(Longholepitch
Foranchorbolt)
(2-dia. 20x88 long hole)
Drain hole(dia. 25)
2-dia. 11-14 U-shape hole
(For dia.8-10 anchor bolts)
Refrigerant pipe
connecting port
(dia. 12.7 flare at gas side)
Refrigerant pipe
connecting port
(dia. 6.4 flare at liquid side)
8-dia. 6 hole
2-dia. 11xL14 long hole
For fixing outdoor unit
(For dia. 8-10 anchor bolts)
dia.holepitch
8
35
52
550
21
6
69.5 147
32 500
780
71
25
22
257483
108
600 90
54108 125
157 79
31 143
145
21
449
483
30
60
30
27
290
306
320
137
93
342
54
dia. 11x14 U-shape hole
Product
external line
Details of B legs
2-dia. hole
R15
600
38
54
320
R15
2-dia. 6 hole
Product
external line
Details of A legs
dia. 11x14 U-shape hole
600
54
38
11
320
2-dia. 11x14 U-shape hples
(For dia. 8-10 anchor bolt)
Suction port
or more
or more
or more Discharge
port
Discharge
port
2-dia. 11x14 long hole
(For dia.8-10 anchor bolt)
or more
600
300
500
150
320
(Unit: mm)
Space required for installation and servicing
(Unit: mm)
DI Digital Inverter 2-3HP : Outdoor unit drawings
2323
DI Digital Inverter 4HP and 5HP: Outdoor unit drawings
Mounting bolt hole
(dia. 12x17 long hole)
Details ofA legs
Mounting bolt
(dia. 12x17 U-shape hole)
Details of B legs
40
40
12
17.536517.5
Drain hole(dia. 20x88)
74118128
Air inlet
port
380
2006 0
Air inlet
port
Air outlet
port
Drain hole(dia. 25)
B legs
46
34
170
75
70383
150 600
A legs
39
96
320
30
2
1
890
24
400
151
8018
9555
94
2
1
255
247
155
1880
135
900
55052
Refrigerant pipe
connecting port
(dia. 9.5 flare at liquid side)
Refrigerant pipe
connecting port
(dia. 15.9 flare at gas side)
9555
17817817860
327
68 518
83 7
765
9555
12 64
1
1
2
Knockout for downward piping
Z views
Refrigerant piping hole
Indoor/Outdoor unit
connecting wire inlet hole
Name Note
Power supply inlet holed ia. 38 Knockout hole
581
534
148
165
(Unit: mm)
24
DI Digital Inverter 6HP : Outdoor unit drawings
Name Note
Refrigerant piping hole
Indoor/Outdoor unit
connecting wire inlet hole
——
Power supply inlet hole Ø38 Kockout hole
1
2
36517.5
74
17.5
128
46
48
40
40
54
34
170
118
380
383
150 600
70
96
39
12
75
200 60
Air inlet port
Air inlet
port
Air outlet
port
Drain hole (Ø28 × 88)
Drain hole (Ø25)
Mounting bolt hole
(Ø12 × 17 long hole)
Mounting bolt hole
(Ø12 × 17 U-shape hole)
B legs
Details of A legs Details of B legs
A legs
5595
21 64
1
657
83 7
Knockout for downward piping
ws
655
12153453485
5595
55
94
95
24
1340
155
605
613
4710875185
360
900
550
60
151531815
400
08810887187 11 8
30
52
320
Refrigerant pipe
connecting port
Refrigerant pipe
connecting port
(Ø15.9 flare at gas side)
2
1
2
1
86
178
327
Z views
(Unit: mm)
2525
DI Big 10HP: Outdoor unit drawings
Knockout (for drain)
Drain hole
(Ø28 x 88 bearing hole)
Drain hole
(Ø25 bearing hole)
B legs
A legs
Air inlet
port
Knockout
(for drain)
Air outlet
Mounting bolt hole
(Ø12 x 17 long hole)
Mounting bolt hole
(Ø12 x 17 U-shaped hole)
Details of A legs Details of B legs
Refrigerant pipe
connecting port
(liquid side)
Refrigerant pipe
connecting port
(gas side)
Z views
Knockout for downward piping
Air inlet
port
Since the connection diameter of the ball valve in the outdoor unit main body is
Ø19.1, use the attached coupling pipe when performing maintenance.
etoNemaN
a
Refrigerant piping hole
Indoor/Outdoor unit
connecting wire inlet hole
—
b Power supply inlet holeØ 38 Knockout hole
Piping Connection Aperture
Radius
Connection
Piping Radius
LiquidG as LiquidG as
12.71 9.1 12.7 28.6
*
*
(Unit: mm)
26
Precautions for using air conditioners
Concerning the automatic defrosting unit
When the outdoor air temperature drops, frost may form on the
heat exchanger of the outdoor unit. In such cases, the automatic
defrosting unit will be activated, and it will take 5 to 8 minutes for the
heating operation to be restored.
Concerning the air conditioner's operating conditions and their
selection
(1) Avoid using the air conditioner in the following locations.
• Locations with acidic or alkaline atmospheres (locations at which
highly acidic or alkaline air is directly drawn in, such as in hot
springs areas from which sulfur gases are given off, or where
chemicals, vinegar, exhaust air from burners, etc., are given off)
The heat exchangers and other parts may become corroded.
• Locations with atmospheres filled with coolant or other machine
oil or steam exhaust (such as at food preparation factories or
machine plants). The heat exchangers may corrode; frost may
form as a result of heat exchanger malfunction; air conditioner
operating performance may be compromised or condensation
may form as a result of clogged filters; plastic parts may incur
damage; heat-insulation materials may become separated, etc.
(2) Before using an air conditioner in any of the following locations,
consult with your dealer or a qualified contractor.
• Locations where vapors from edible oils are given off (such
as in bakeries or kitchens and restaurants that use edible
oils) ...The air conditioner's operating performance may be
compromised or condensation may form as a result of clogged
filters, and the plastic parts may incur damage. In line with the
prevailing conditions, take countermeasures such as tailoring the
installation conditions in accordance with the conditions, using
air conditioners designed for kitchens or oil guard filters, etc.
• Locations with disinfectant-induced chlorine atmospheres (water
tanks, etc.) The metal parts in the heat exchangers, motors, etc.,
may become corroded.
• Locations with high salinity (coastal areas, etc.) Corrosion
may occur so use outdoor units specifically designed to
withstand exposure to salt.
• Locations where power is supplied from independent power
generators. The power line frequency and/or voltage may
fluctuate, possibly causing the air conditioner to malfunction.
• Locations where high frequencies or electrical noise is
generated (from high-frequency welders used for vinyl welding
and processing, high-frequency therapeutic devices used
for thermotherapy, etc.) The electronic components may be
adversely affected, possibly causing the air conditioner to
malfunction.
• Locations where electronic equipment is installed. Electrical
noise may adversely affect the operation of the electronic
equipment.
(3) Concerning use in locations with high ceilings
• In locations with high ceilings, use of circulators for improving
the temperature distribution during heating is recommended.
(4) Concerning use in high-humidity environments
• When the ceiling-recessed type of indoor unit is installed in a
location, such as those described below, and it is very hot and
humid inside the ceiling, condensation may form on the external
surfaces of the indoor unit and drip down. In such cases, add
external heat-insulating materials.
– Locations such as food preparation sites in which the areas
above the ceilings are hot and humid
– Locations in which outside air is drawn in and routed above the
ceiling
– Above ceilings with a slate roof or tiled roof overhead
(5) Even when an air conditioner is shut down, it will still consume a
small amount of power to protect the unit. If the air conditioner
will not be used for a prolonged period, turn OFF the main switch
(ground fault circuit breaker). However, before the unit is to be
used again, turn ON the main switch (ground fault circuit breaker)
for at least 12 hours in order to prevent trouble.
SAFETY PRECAUTIONS
For operation:
•	Before use, read through the operating instructions to ensure proper use.
Concerning the purpose for which the air conditioners are to be used
•	The air conditioners presented in this catalogue are air conditioning/heating units to be used solely by general consumers.
–	 Do not use these air conditioners for special applications such as for the storage of food items, animals, plants, precision machines or works
of art. Doing so may degrade the quality of the items.
–	 Do not use these air conditioners for air-conditioning applications in vehicles or ships. Doing so may cause water and/or power leakages.
Installation and the use of refrigerants not specified by Toshiba Carrier Corporation
Toshiba refrigeration and air-conditioning units are designed and
manufactured on the assumption that the product is used with a
specific refrigerant suitable for each unit.
We have recently seen some cases where the type of refrigerant
used is different from the one originally installed in the product.
Such actions may cause mechanical defects, malfunctions, failures
and in some cases result in a serious safety issue. Therefore do
not install any refrigerant other than the one specified by Toshiba
Carrier Corporation for its respective products.
The type of the refrigerant used for each of our products is shown in the
accompanying owners manual, or on the product label attached on the
product itself.
Toshiba Carrier Corporation shall not assume any liability for failures,
malfunctions or safety in its products if the refrigerant used is different
from the one specified.
2727
Toshiba

More Related Content

What's hot

Marketing plan - Prince de lu
Marketing plan - Prince de luMarketing plan - Prince de lu
Marketing plan - Prince de luSepideh Rayegan
 
Non alcoholic beer - VERGE
Non alcoholic beer - VERGENon alcoholic beer - VERGE
Non alcoholic beer - VERGETope Adedayo
 
HersheysMarketingPlan
HersheysMarketingPlanHersheysMarketingPlan
HersheysMarketingPlanTia Aquart
 
Absolut vodka, developing high brand loyalty-marketing strategy
Absolut vodka, developing high brand loyalty-marketing strategyAbsolut vodka, developing high brand loyalty-marketing strategy
Absolut vodka, developing high brand loyalty-marketing strategyFloyd Tavares
 
Toy Industry Analysis
Toy Industry AnalysisToy Industry Analysis
Toy Industry AnalysisOliviah Cook
 
El sistema de informaciĂłn de la AEAT / Agencia Estatal de AdministraciĂłn Trib...
El sistema de informaciĂłn de la AEAT / Agencia Estatal de AdministraciĂłn Trib...El sistema de informaciĂłn de la AEAT / Agencia Estatal de AdministraciĂłn Trib...
El sistema de informaciĂłn de la AEAT / Agencia Estatal de AdministraciĂłn Trib...EUROsociAL II
 
Strategic Analysis of Microsoft Corp. (2014)
Strategic Analysis of Microsoft Corp. (2014)Strategic Analysis of Microsoft Corp. (2014)
Strategic Analysis of Microsoft Corp. (2014)Chinmay Chauhan
 
Heineken Case Study business Analysis
Heineken Case Study business AnalysisHeineken Case Study business Analysis
Heineken Case Study business Analysisjin88lin
 
Strategic management (sony)
Strategic management (sony)Strategic management (sony)
Strategic management (sony)Waseque Uddin Ahmed
 
Innovation of Bang & Olufsen
Innovation of Bang & OlufsenInnovation of Bang & Olufsen
Innovation of Bang & OlufsenWesley Shu
 
"The World's Most Valuable Whiteboard Session" by Steve Jobs
"The World's Most Valuable Whiteboard Session" by Steve Jobs"The World's Most Valuable Whiteboard Session" by Steve Jobs
"The World's Most Valuable Whiteboard Session" by Steve JobsJeremy Waite
 
2012大中華薪資指南
2012大中華薪資指南2012大中華薪資指南
2012大中華薪資指南Jennifer Yu
 
New Opportunities in Global Food Market
New Opportunities in Global Food MarketNew Opportunities in Global Food Market
New Opportunities in Global Food MarketEuromonitor International
 
Murhy's case study
Murhy's case studyMurhy's case study
Murhy's case studyPRAVEENBEN3
 
Macroeconomic Analysis of Brazil
Macroeconomic Analysis of BrazilMacroeconomic Analysis of Brazil
Macroeconomic Analysis of BrazilFernando Alves
 

What's hot (20)

Marketing plan - Prince de lu
Marketing plan - Prince de luMarketing plan - Prince de lu
Marketing plan - Prince de lu
 
Non alcoholic beer - VERGE
Non alcoholic beer - VERGENon alcoholic beer - VERGE
Non alcoholic beer - VERGE
 
HersheysMarketingPlan
HersheysMarketingPlanHersheysMarketingPlan
HersheysMarketingPlan
 
Absolut vodka, developing high brand loyalty-marketing strategy
Absolut vodka, developing high brand loyalty-marketing strategyAbsolut vodka, developing high brand loyalty-marketing strategy
Absolut vodka, developing high brand loyalty-marketing strategy
 
Toy Industry Analysis
Toy Industry AnalysisToy Industry Analysis
Toy Industry Analysis
 
El sistema de informaciĂłn de la AEAT / Agencia Estatal de AdministraciĂłn Trib...
El sistema de informaciĂłn de la AEAT / Agencia Estatal de AdministraciĂłn Trib...El sistema de informaciĂłn de la AEAT / Agencia Estatal de AdministraciĂłn Trib...
El sistema de informaciĂłn de la AEAT / Agencia Estatal de AdministraciĂłn Trib...
 
XBox IMC Plan
XBox IMC PlanXBox IMC Plan
XBox IMC Plan
 
Strategic Analysis of Microsoft Corp. (2014)
Strategic Analysis of Microsoft Corp. (2014)Strategic Analysis of Microsoft Corp. (2014)
Strategic Analysis of Microsoft Corp. (2014)
 
Heineken Case Study business Analysis
Heineken Case Study business AnalysisHeineken Case Study business Analysis
Heineken Case Study business Analysis
 
Ben And Jerrys Big
Ben And Jerrys BigBen And Jerrys Big
Ben And Jerrys Big
 
Strategic management (sony)
Strategic management (sony)Strategic management (sony)
Strategic management (sony)
 
Innovation of Bang & Olufsen
Innovation of Bang & OlufsenInnovation of Bang & Olufsen
Innovation of Bang & Olufsen
 
Consumer Behaviour Report - Ben & Jerry's
Consumer Behaviour Report - Ben & Jerry's Consumer Behaviour Report - Ben & Jerry's
Consumer Behaviour Report - Ben & Jerry's
 
"The World's Most Valuable Whiteboard Session" by Steve Jobs
"The World's Most Valuable Whiteboard Session" by Steve Jobs"The World's Most Valuable Whiteboard Session" by Steve Jobs
"The World's Most Valuable Whiteboard Session" by Steve Jobs
 
2012大中華薪資指南
2012大中華薪資指南2012大中華薪資指南
2012大中華薪資指南
 
New Opportunities in Global Food Market
New Opportunities in Global Food MarketNew Opportunities in Global Food Market
New Opportunities in Global Food Market
 
Murhy's case study
Murhy's case studyMurhy's case study
Murhy's case study
 
Apple SWOT Analysis 2018
Apple SWOT Analysis 2018Apple SWOT Analysis 2018
Apple SWOT Analysis 2018
 
Macroeconomic Analysis of Brazil
Macroeconomic Analysis of BrazilMacroeconomic Analysis of Brazil
Macroeconomic Analysis of Brazil
 
Manufacturing lighthouses
Manufacturing lighthousesManufacturing lighthouses
Manufacturing lighthouses
 

Similar to Toshiba

Super inverter epcen08 114-catalogues_english (2)
Super inverter epcen08 114-catalogues_english (2)Super inverter epcen08 114-catalogues_english (2)
Super inverter epcen08 114-catalogues_english (2)Henry Hollands
 
Innovations - Toshiba 17.02.14
Innovations - Toshiba 17.02.14Innovations - Toshiba 17.02.14
Innovations - Toshiba 17.02.14Overbury
 
Điᝁu hòa âm trần LG 36000BTU
Điᝁu hòa âm trần LG 36000BTUĐiᝁu hòa âm trần LG 36000BTU
Điᝁu hòa âm trần LG 36000BTUMyravn1
 
Ventilation
VentilationVentilation
VentilationDantherm
 
Catalog Biến tần Frenic-HVAC (Fuji Electric)
Catalog Biến tần Frenic-HVAC (Fuji Electric)Catalog Biến tần Frenic-HVAC (Fuji Electric)
Catalog Biến tần Frenic-HVAC (Fuji Electric)Beeteco
 
Rittal top therm_chiller
Rittal top therm_chillerRittal top therm_chiller
Rittal top therm_chillerEeu SC
 
1372002384 satellite msp
1372002384 satellite msp1372002384 satellite msp
1372002384 satellite mspAya Khaled Ezz
 
Fuji tu dong hoa catalog frenic-hvac-dienhathe.org
Fuji tu dong hoa catalog frenic-hvac-dienhathe.orgFuji tu dong hoa catalog frenic-hvac-dienhathe.org
Fuji tu dong hoa catalog frenic-hvac-dienhathe.orgDien Ha The
 
42GWC Hydronic Cassette Fan Coil Units.pdf
42GWC Hydronic Cassette Fan Coil Units.pdf42GWC Hydronic Cassette Fan Coil Units.pdf
42GWC Hydronic Cassette Fan Coil Units.pdfCarrier Singapore
 
Specificaties Fresh-r
Specificaties Fresh-rSpecificaties Fresh-r
Specificaties Fresh-rFresh-r
 
Dekon vrf system brief introduction
Dekon vrf system brief introductionDekon vrf system brief introduction
Dekon vrf system brief introductionSimon MECO FanCoil Unit
 
YORK® AMICHI™ Series Air-Cooled DC Inverter Scroll Chillers and Heat Pumps
YORK® AMICHI™ Series Air-Cooled DC Inverter Scroll Chillers and Heat PumpsYORK® AMICHI™ Series Air-Cooled DC Inverter Scroll Chillers and Heat Pumps
YORK® AMICHI™ Series Air-Cooled DC Inverter Scroll Chillers and Heat PumpsIlia Iovtchev
 
Lcp hybrid –_effi_cient_performance_with_heat_pipe_technology
Lcp hybrid –_effi_cient_performance_with_heat_pipe_technologyLcp hybrid –_effi_cient_performance_with_heat_pipe_technology
Lcp hybrid –_effi_cient_performance_with_heat_pipe_technologyEeu SC
 
Unico System for Commercial HVAC Promotional Flyer
Unico System for Commercial HVAC Promotional FlyerUnico System for Commercial HVAC Promotional Flyer
Unico System for Commercial HVAC Promotional FlyerUniqueIndoorComfortLibertyville
 
Sb compact dx_ver.1.0_en
Sb compact dx_ver.1.0_enSb compact dx_ver.1.0_en
Sb compact dx_ver.1.0_enYury Naumov
 
Eta draco series reflow oven
Eta draco series reflow ovenEta draco series reflow oven
Eta draco series reflow ovenMark Tung
 
Eta draco series reflow oven
Eta draco series reflow ovenEta draco series reflow oven
Eta draco series reflow ovenLucy Xiao
 

Similar to Toshiba (20)

VRV IV
VRV IVVRV IV
VRV IV
 
Carrier Ducted Brochure
Carrier Ducted Brochure Carrier Ducted Brochure
Carrier Ducted Brochure
 
Carrier Inverter Ducted_tcm175-49778 (1).pdf
Carrier Inverter Ducted_tcm175-49778 (1).pdfCarrier Inverter Ducted_tcm175-49778 (1).pdf
Carrier Inverter Ducted_tcm175-49778 (1).pdf
 
Super inverter epcen08 114-catalogues_english (2)
Super inverter epcen08 114-catalogues_english (2)Super inverter epcen08 114-catalogues_english (2)
Super inverter epcen08 114-catalogues_english (2)
 
Innovations - Toshiba 17.02.14
Innovations - Toshiba 17.02.14Innovations - Toshiba 17.02.14
Innovations - Toshiba 17.02.14
 
Điᝁu hòa âm trần LG 36000BTU
Điᝁu hòa âm trần LG 36000BTUĐiᝁu hòa âm trần LG 36000BTU
Điᝁu hòa âm trần LG 36000BTU
 
Ventilation
VentilationVentilation
Ventilation
 
Catalog Biến tần Frenic-HVAC (Fuji Electric)
Catalog Biến tần Frenic-HVAC (Fuji Electric)Catalog Biến tần Frenic-HVAC (Fuji Electric)
Catalog Biến tần Frenic-HVAC (Fuji Electric)
 
Rittal top therm_chiller
Rittal top therm_chillerRittal top therm_chiller
Rittal top therm_chiller
 
1372002384 satellite msp
1372002384 satellite msp1372002384 satellite msp
1372002384 satellite msp
 
Fuji tu dong hoa catalog frenic-hvac-dienhathe.org
Fuji tu dong hoa catalog frenic-hvac-dienhathe.orgFuji tu dong hoa catalog frenic-hvac-dienhathe.org
Fuji tu dong hoa catalog frenic-hvac-dienhathe.org
 
42GWC Hydronic Cassette Fan Coil Units.pdf
42GWC Hydronic Cassette Fan Coil Units.pdf42GWC Hydronic Cassette Fan Coil Units.pdf
42GWC Hydronic Cassette Fan Coil Units.pdf
 
Specificaties Fresh-r
Specificaties Fresh-rSpecificaties Fresh-r
Specificaties Fresh-r
 
Dekon vrf system brief introduction
Dekon vrf system brief introductionDekon vrf system brief introduction
Dekon vrf system brief introduction
 
YORK® AMICHI™ Series Air-Cooled DC Inverter Scroll Chillers and Heat Pumps
YORK® AMICHI™ Series Air-Cooled DC Inverter Scroll Chillers and Heat PumpsYORK® AMICHI™ Series Air-Cooled DC Inverter Scroll Chillers and Heat Pumps
YORK® AMICHI™ Series Air-Cooled DC Inverter Scroll Chillers and Heat Pumps
 
Lcp hybrid –_effi_cient_performance_with_heat_pipe_technology
Lcp hybrid –_effi_cient_performance_with_heat_pipe_technologyLcp hybrid –_effi_cient_performance_with_heat_pipe_technology
Lcp hybrid –_effi_cient_performance_with_heat_pipe_technology
 
Unico System for Commercial HVAC Promotional Flyer
Unico System for Commercial HVAC Promotional FlyerUnico System for Commercial HVAC Promotional Flyer
Unico System for Commercial HVAC Promotional Flyer
 
Sb compact dx_ver.1.0_en
Sb compact dx_ver.1.0_enSb compact dx_ver.1.0_en
Sb compact dx_ver.1.0_en
 
Eta draco series reflow oven
Eta draco series reflow ovenEta draco series reflow oven
Eta draco series reflow oven
 
Eta draco series reflow oven
Eta draco series reflow ovenEta draco series reflow oven
Eta draco series reflow oven
 

Recently uploaded

Keppel Ltd. 1Q 2024 Business Update Presentation Slides
Keppel Ltd. 1Q 2024 Business Update  Presentation SlidesKeppel Ltd. 1Q 2024 Business Update  Presentation Slides
Keppel Ltd. 1Q 2024 Business Update Presentation SlidesKeppelCorporation
 
Call Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any TimeCall Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any Timedelhimodelshub1
 
Catalogue ONG NUOC PPR DE NHAT .pdf
Catalogue ONG NUOC PPR DE NHAT      .pdfCatalogue ONG NUOC PPR DE NHAT      .pdf
Catalogue ONG NUOC PPR DE NHAT .pdfOrient Homes
 
Non Text Magic Studio Magic Design for Presentations L&P.pptx
Non Text Magic Studio Magic Design for Presentations L&P.pptxNon Text Magic Studio Magic Design for Presentations L&P.pptx
Non Text Magic Studio Magic Design for Presentations L&P.pptxAbhayThakur200703
 
Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...
Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...
Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...lizamodels9
 
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...lizamodels9
 
The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024christinemoorman
 
Tech Startup Growth Hacking 101 - Basics on Growth Marketing
Tech Startup Growth Hacking 101  - Basics on Growth MarketingTech Startup Growth Hacking 101  - Basics on Growth Marketing
Tech Startup Growth Hacking 101 - Basics on Growth MarketingShawn Pang
 
BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,noida100girls
 
Pitch Deck Teardown: NOQX's $200k Pre-seed deck
Pitch Deck Teardown: NOQX's $200k Pre-seed deckPitch Deck Teardown: NOQX's $200k Pre-seed deck
Pitch Deck Teardown: NOQX's $200k Pre-seed deckHajeJanKamps
 
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...lizamodels9
 
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...lizamodels9
 
BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,noida100girls
 
Case study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailCase study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailAriel592675
 
A.I. Bot Summit 3 Opening Keynote - Perry Belcher
A.I. Bot Summit 3 Opening Keynote - Perry BelcherA.I. Bot Summit 3 Opening Keynote - Perry Belcher
A.I. Bot Summit 3 Opening Keynote - Perry BelcherPerry Belcher
 
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / NcrCall Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncrdollysharma2066
 
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130  Available With RoomVIP Kolkata Call Girl Howrah 👉 8250192130  Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Roomdivyansh0kumar0
 
2024 Numerator Consumer Study of Cannabis Usage
2024 Numerator Consumer Study of Cannabis Usage2024 Numerator Consumer Study of Cannabis Usage
2024 Numerator Consumer Study of Cannabis UsageNeil Kimberley
 
RE Capital's Visionary Leadership under Newman Leech
RE Capital's Visionary Leadership under Newman LeechRE Capital's Visionary Leadership under Newman Leech
RE Capital's Visionary Leadership under Newman LeechNewman George Leech
 

Recently uploaded (20)

Keppel Ltd. 1Q 2024 Business Update Presentation Slides
Keppel Ltd. 1Q 2024 Business Update  Presentation SlidesKeppel Ltd. 1Q 2024 Business Update  Presentation Slides
Keppel Ltd. 1Q 2024 Business Update Presentation Slides
 
Call Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any TimeCall Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any Time
 
Catalogue ONG NUOC PPR DE NHAT .pdf
Catalogue ONG NUOC PPR DE NHAT      .pdfCatalogue ONG NUOC PPR DE NHAT      .pdf
Catalogue ONG NUOC PPR DE NHAT .pdf
 
Non Text Magic Studio Magic Design for Presentations L&P.pptx
Non Text Magic Studio Magic Design for Presentations L&P.pptxNon Text Magic Studio Magic Design for Presentations L&P.pptx
Non Text Magic Studio Magic Design for Presentations L&P.pptx
 
Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...
Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...
Lowrate Call Girls In Laxmi Nagar Delhi ❤️8860477959 Escorts 100% Genuine Ser...
 
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
 
The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024
 
Tech Startup Growth Hacking 101 - Basics on Growth Marketing
Tech Startup Growth Hacking 101  - Basics on Growth MarketingTech Startup Growth Hacking 101  - Basics on Growth Marketing
Tech Startup Growth Hacking 101 - Basics on Growth Marketing
 
BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In BELLMONT HOTEL ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
 
Pitch Deck Teardown: NOQX's $200k Pre-seed deck
Pitch Deck Teardown: NOQX's $200k Pre-seed deckPitch Deck Teardown: NOQX's $200k Pre-seed deck
Pitch Deck Teardown: NOQX's $200k Pre-seed deck
 
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
 
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
 
BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Old Faridabad ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
 
Case study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailCase study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detail
 
Best Practices for Implementing an External Recruiting Partnership
Best Practices for Implementing an External Recruiting PartnershipBest Practices for Implementing an External Recruiting Partnership
Best Practices for Implementing an External Recruiting Partnership
 
A.I. Bot Summit 3 Opening Keynote - Perry Belcher
A.I. Bot Summit 3 Opening Keynote - Perry BelcherA.I. Bot Summit 3 Opening Keynote - Perry Belcher
A.I. Bot Summit 3 Opening Keynote - Perry Belcher
 
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / NcrCall Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
Call Girls in DELHI Cantt, ( Call Me )-8377877756-Female Escort- In Delhi / Ncr
 
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130  Available With RoomVIP Kolkata Call Girl Howrah 👉 8250192130  Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Room
 
2024 Numerator Consumer Study of Cannabis Usage
2024 Numerator Consumer Study of Cannabis Usage2024 Numerator Consumer Study of Cannabis Usage
2024 Numerator Consumer Study of Cannabis Usage
 
RE Capital's Visionary Leadership under Newman Leech
RE Capital's Visionary Leadership under Newman LeechRE Capital's Visionary Leadership under Newman Leech
RE Capital's Visionary Leadership under Newman Leech
 

Toshiba

  • 1. Inverter Air Conditioning for Light Commercial Use
  • 2. Digital InverterDI Toshiba solutions Toshiba offers a solution for all applications: residential, light commercial and larger commercial buildings. For small commercial premises, products are designed to deliver top performance combined with energy efficiency. Toshiba’s commitment to society drives a company-wide focus on attention to the details through every stage of the development process, from design to user field tests. Installations using our products and systems therefore feature a higher standard of indoor air quality, sound levels, energy savings, and environmental awareness. Superior comfort Toshiba can help you create a comfortable space while also caring for the environment.
  • 3. 3 Very efficient energy consumption, Keeps down operating costs. Superior EER ECO-driving DC twin rotary compressor Vector-controlled inverter High efficiency heat-transfer (flat fin) DC fan motor Bat wing fan Wide-flow grille DC twin rotary compressor Vector IPDU control changes the motor current wave to a smooth sine pattern so that noise emitted from the drive units is greatly reduced. Heat-transfer tube with improved heat-transfer coefficient. Highly Efficient DC Motor. New development for high-pressure low-volume fan. Optimizing ventilation performance, Bringing out the full effect of fan and motor. A low minimum speed of 10 rps has been achieved. Light Commercial The Toshiba Digital Inverter series air conditioners combine economy and ecology in a compact body. They feature state- of-the-art technology, flexible control, and easy installation to bring natural comfort and convenience to any business environment. Consists of Cassette and Ducted units which has excellent efficiency, not only under rated EER conditions, but also during partial load which is the larger part of actual operating conditions. A low minimum speed of 10 rps has been achieved. This has further improved the operating efficiency when the load is low (the minimum in Series 2 was 15 rps). Large-area magnet Rotor with slit High power motor Newly designed compression path More precise components The structure and shape of each compressor component has been optimised. The area of the rotor magnet has been increased and a slit introduced to the design. These improvements have further enhanced efficiency and reduced noise. Operation in Power Save Mode enables power peaks to be cut. 2 HP 5 HP4 HP3 HP 3.02 3.31 2.80 5.0 4.0 3.0 2.0 1.0 0.0 (EER) 3.21 Digital Inverter / New 4-Way Cassette Note: Actual component may vary considerably from specifications depending on product model.
  • 4. An ozone layer depletion coefficient of zero has become absolutely essential for an advanced air conditioning system. R410A refrigerant Fits with various size room and form - Combination : Same type and capacity of indoor units - Twin kit Line up Twin split System Quiet operation Low-noise design. If the outdoor temperature is 30°C or less, operates at under 45 db. It’s possible to automatically operate the quiet operation mode below 35°C air temperature. Self-Clean operation-Continuing high performance for energy saving This enables the 4-Way Cassette type to maintain energy efficiency. Water Oil/ Aqua resin coating Dirt Self-Clean Operation - The mechanism of the wash-off 1. The aqua resin coating prevents dirt from sticking to the fins. 2. The condensation water flows and washes away dirt. 3. After washing, a drying operation suppresses the propagation of mold. 4
  • 5. Digital InverterDI Extremely lightweight and compact outdoor unit Lighter than the current model by 8 kg (11%) 4 HP 5 HP 1104ATP-E 1404ATP-E -8kg68kg previous model:76kg Small compact size chassis Reduces installation spaces and enables a more efficient use of the site. Easy to install the outdoor units on a double-decked and easy to install on a wall. Current model New model Wide-Utility function Heating operation is possible starting from an outdoor temperature of -20°C, while cooling operation is possible at -15°C and up to 46 outdoor temperature. This enables wider applications and use of the system in colder regions. Outstandingly quiet operation & save operation setting Night operation make it possible to suppress the operation sound of the outdoor unit within the time which you desire. (12dB(A) reduction)* Easy and safty operation for maintenance of the outdoor unit. Inspection window makes it easy to find switch that requires operation and reduces the risk of electrical shock. Remarkable energy efficiency Industry’s top-class energy-saving 2,3 HP 4,5 HP (Max.10%UP) Cover Inspection window Maintenance Switch (2 tact switches) Maintenance light (6LED) Save operation setting is available from 50% to 100% by 1% Quiet operation & save operation setting available for 2HP, 3HP, 4HP and 5HP *5HP Outdoor unit, Heating. Note: Night operation - Necessity to set the Lite-vision plus remote controller (RBC-AMS51E) Save operation - Necessity to set the Lite-vision plus remote controller (RBC-AMS51E), RBC-AMT32E 55
  • 6. DIBIG DI Big proposes competitive cost systems solution for medium size applications like Shops and Small Office buildings. Simultaneous operation of 2, 3 or up to 4 indoor unit can be installed as twin, triple and double twin systems with single outdoor unit. Compact outdoor unit Small footprint in only 0.29 m2, Compact design in size (W 900mmx D 320mm) allows opportunity for more space saving. High efficiency EER/COP* performance DI Big is equipped with a new twin-rotary DC inverter compressor with high efficiency R410A refrigerant. A new technology twin-rotary DC compressor, 100W +100W output Highly-efficient DC fan motor, propeller fan for newly developed 3-row heat exchanger. EER / COP = 2.81 / 3.61 ( With 4-way cassette twin system of 10HP) Wider discharge port for less pressure loss Screw connection for larger current Decreasing oil discharge for reliability Larger displacement cylinder (55cm3/rev) Expanded operating temperature range Air conditioning system designing is easy with DI-BIG because of its expanded operation range. Heater operation is possible starting from an outdoor temperature of -20°C, while cooling operation is possible at -15°C and up to 46 outdoor temperature. This enables wider applications and use of the system in colder regions. DI BIG Outdoor temp. range when cooling* -15˚C to 46˚C Outdoor temp. range when heating* -20˚C to 15˚C Heating operation range 15˚C0˚C-15˚C-20˚C *Cooling : ˚CDB, Heating: ˚CWB DI BIGDI BIG Compatible with pipes up to 70 meters long with a maximum height difference of 30 meters height 6
  • 7. Equivalent HP 2HP 3HP 4HP 5HP 6HP Standard model (RAV-) SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E Heavy Anti-Corrosion protection model (RAV-) SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E 4-Way Cassette type Single (RAV-) SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E N/A Twin (RAV-) N/A N/A SM564UTP-E x 2 SM804UTP-E x 2 SM804UTP-E x 2 Triple (RAV-) N/A N/A N/A N/A SM564UTP-E x 3 Standard Duct type Single (RAV-) SM566BTP-E* SM806BTP-E* SM1106BTP-E* SM1406BTP-E* N/A Twin (RAV-) N/A N/A SM566BTP-E* x 2 SM806BTP-E* x 2 SM806BTP-E* x 2 Triple (RAV-) N/A N/A N/A N/A SM566BTP-E* x 3 Concealed Duct High Static Pressure type Single (RAV-) N/A N/A N/A N/A SM1603DT-A Twin (RAV-) N/A N/A N/A N/A N/A Triple (RAV-) N/A N/A N/A N/A N/A Digital Inverter 1-phase model *1 Rated conditions Cooling : Indoor air temperature 27o C DB / 19o C WB, Outdoor air temperature 35o C DB Heating : Indoor air temperature 20o C DB, Outdoor air temperature 7o C DB / 6o C WB *2 Sound pressure levels measured in an anechoic chamber 77
  • 8. Equivalent HP 10HP 50Hz Standard model (RAV-) SM2804AT8-E Heavy Anti-Corrosion protection model (RAV-) SM2804AT8ZG-E 4-Way Cassette type Single (RAV-) N/A Twin (RAV-) SM1404UTP-E x 2 Triple (RAV-) SM804UTP-E x 3 Double twin (RAV-) SM804UTP-E x 4 Standard Duct type Single (RAV-) N/A Twin (RAV-) SM1406BTP-E* x 2 Triple (RAV-) SM806BTP-E* x 3 Double twin (RAV-) SM806BTP-E* x 4 Concealed Duct High Static Pressure type Single (RAV-) SM2802DT-E Twin (RAV-) N/A Triple (RAV-) N/A Double twin (RAV-) N/A Digital Inverter Big 3-phase model *1 Rated conditions Cooling : Indoor air temperature 27o C DB / 19o C WB, Outdoor air temperature 35o C DB Heating : Indoor air temperature 20o C DB, Outdoor air temperature 7o C DB / 6o C WB *2 Sound pressure levels measured in an anechoic chamber 8
  • 9. rAV-SM∗∗∗4UTP-E 4-Way Cassette type RBC-U31PGP(W)-E The wide air flow in all direction Multi-louver individual control Individual louver control enables airflow to be chosen according to user preferences. The angles of each louver can be set individually in 3 different choices of swing patterns; Standard swing, Diagonally opposite swing and Turn-around swing (1) Standard swing (2) Diagonally opposite swing (3) Turn-around swing New Long-life pre-filter A new long-life pre-filter has a surface 1.5 times of current filters to improve Dust-collection performance. Built-in condensate drain pump Easy installation Light weight unit (24kg at 5HP) Easy panel installation, The panel is attached using the bolt that is already installed on the indoor unit. 300mm or less 850mm or less 210mm Panel Wide flow louver type 4-Way Cassette type Digital Inverter . Comfort Inverter Allows step-less regulation of the air-conditioner’s power,which reduces energy consumption and improves comfort. . Individual Louvre control Enables airflows to be chosen according to user preferences. . Hot Start When using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room. Dry Gradually dehumidifies the room to create even greater comfort. Operativity Filter Sign Automatic displays on the remote controller say when to perform maintenance for the indoor unit filter. Limit Timer Uses a 168-hour timer with three modes - “ON timer”, “OFF timer” and “Repeat OFF timer”. Installation Cooler Compatible with an Outdoor Temperature of -15 ° C Stable cooler operation is possible when the outdoor temperature is as low as -15 ° C. Built-in Drain Pump The built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.) Long-life Filter Built-in long-life filter makes maintenance easier. Automatic Air Volume control Depending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low. Auto-turn Louvre Air outlet grilles move automatically to fill every corner of the room with warm or cool air. *European market only 99
  • 10. Physical data Indoor unit (RAV-) SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E Standard air flow (H/M/L) CFM 617/512/459 723/564/476 1182/847/688 1235/847/723 Sound pressure level (H/M/L) dB(A) 32/29/28 35/31/28 43/38/33 44/38/34 Main unit dimensions (H/W/D) mm 256/840/840 256/840/840 319/840/840 319/840/840 Weightkg 20 20 24 24 Panel dimensions (H/W/D) mm 30/950/950 30/950/950 30/950/950 30/950/950 Panel weight kg 4.2 4.2 4.2 4.2 Physical data Outdoor Unit Equivalent HP 2HP 3HP 4HP 5HP Out door unit Standard model (RAV-) SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E Heavy Anti-Corrosion protection model (RAV-) SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E Power supply 1-phase 50Hz 230V (220–240V) Compressor type DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 Standard / Min. pipe length m 7.5 / 5 7.5 / 5 7.5 / 5 7.5 / 5 Max. pipe total length m 30 30 50 50 Maximum height difference m 30 30 30 30 Outer dimensions (H/W/D) mm 550/780/290 550/780/290 890/900/320 890/900/320 Weight kg 40 44 68 68 Sound pressure level, Cooling/Heating*2 dB(A) 46/48 48/52 53/54 54/55 Operating range, Cooling/Heating °C -15~46 / -15~15 Out door unit Standard model (RAV-) SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E Heavy Anti-Corrosion protection model (RAV-) SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E Indoor unit (RAV-) SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E Cooling*1 Capacity kW 5.0 6.7 10.0 12.0 Range, min-max kW 1.5-5.6 1.5-8.0 3.0-11.2 3.0-13.2 Power consumption kW 1.56 2.22 3.02 4.29 EER (Energy Efficiency Ratio) Capacity 100% 3.21 3.02 3.31 2.80 Capacity 80% 4.00 3.77 4.08 3.53 Capacity 50% 5.21 5.49 5.10 5.00 Heating*1 Capacity kW 5.3 7.7 11.2 12.8 Range, min-max kW 1.5-6.3 1.5-9.0 3.0-13.0 3.0-16.0 Power consumption kW 1.36 2.13 2.93 3.40 COP (Coefficient of Performance) Capacity 100% 3.90 3.62 3.82 3.76 Capacity 80% 4.37 4.22 4.23 4.30 Capacity 50% 5.41 5.50 5.19 5.12 Power supply 1-phase 50Hz 230V (220–240V) Performance dataDI-Digital Inverter 10
  • 11. RAV-SM***4UTP-E 155 28.5 61 5764 187 32 Celling bottom surface Knockoutfor fresh airintake φ100 Z view 300orless Stand-up 661orless Stand-up850orless Bottom faceofceiling Drain standing-up size A B 860to 910Ceiling open dim ension 860to910Ceilingopendimension 1000orm ore 1000orm ore 15or more 15or more 1000or more Space required forinstallation and servicing Z SM564UTP-E SM1104UTP-E, SM1404UTP-E AModel RAV- 256 319 74 137 B (Unit:mm) C D 12.7 15.9 6.4 9.5 SM804UTP-E 256 74 C D 15.9 9.5 Options Packing A Air discharge parts A Refrigerant piping side Drain piping side Packing B Packing B Air discharge parts B Air discharge parts C Air inlet grille Ceiling panel Fresh air inlet box Air discharge direction kit Spacer for height adjustment Spacer for height adjustment RBC-U31PGP(W)-E RBC-U31PGP(WS)-E TCB-SP1602UE TCB-GB1602UE TCB-GFC1602UE TCB-FF101URE2 TCB-BC1602UE Bottom face of Ceiling 1000 or more1000 or more 1000or more 15or more 860to910Ceilingopendimension Ceiling Electric parts box Ceiling 860 to 910 Ceiling open dimension Space required for installation and servicing bottom surface Knockout for fresh air intake Drain standing-up size Z view 300 or less Stand-up850orless Stand-up 661orless 15or more Hanging bolt M10 or Ceiling panel (sold separately) of ceiling Bottom face For branch duct Knockout square hole (procured by locally) Hanging bolt pitch Panel external dimension Panelexternaldimension Hangingboltpitch Bottomface ofceiling Take-inport ofwiring Drainpipe connectionport squarehole (Material:PP) Refrigerantpipe connectingport (Liquidside) (Gaside) Refrigerantpipe connectingport ForbranchductKnockout 1111
  • 12. Compact sizing Compact size especially in height (275 mm), new slimmer chassis offers wide range of installation opportunities to customer. Standard Duct type rav-sm∗∗∗6Btp-E* Wide range of application opportunities High static pressure External static pressure can be raised as high as 120 Pa, so that all areas of the room can be reached for even temperature distribution, no matter how complex the layout. 275mm 275mm Built-in High-lift drain pump# The flexible piping layout is made possible by an optionally available drain-pump kit that raises the drain piping up to 29 cm from the drain port. Flexible duct is accessible, Allows complete design flexibility Polygonal rooms Narrow rooms Rooms with fixtures and obstacles New spigot shaped flange as new accessories New spigot shaped flange has higher static pressure with optimized design, the static pressure drops only 20Pa from rectangle flange states. Maximum Static pressure will be 100Pa* with all models. (*static pressure with filter which included in, and intake from back ward) . . Comfort Inverter Allows step-less regulation of the air-conditioner’s power,which reduces energy consumption and improves comfort. . Hot Start When using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room. Dry Gradually dehumidifies the room to create even greater comfort. Operativity Filter Sign Automatic displays on the remote controller say when to perform maintenance for the indoor unit filter. Limit Timer Uses a 168-hour timer with three modes - “ON timer”, “OFF timer” and “Repeat OFF timer”. Installation Cooler Compatible with an Outdoor Temperature of -15 ° C Stable cooler operation is possible when the outdoor temperature is as low as -15 ° C. Built-in Drain Pump The built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.) Long-life Filter Built-in long-life filter makes maintenance easier. Automatic Air Volume control Depending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low. Standard Duct type Digital Inverter Spigot shaped flange TCB-SF56C6BEP TCB-SF80C6BEP TCB-SF160C6BEP #Not available with 6HP and 10HPhigh static duct IDU 12
  • 13. Physical data Equivalent HP 2HP 3HP 4HP 5HP 6HP Out door unit Standard model (RAV-) SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E Heavy Anti-Corrosion protection model (RAV-) SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E Power supply 1-phase 50Hz 230V (220–240V) 1-phase 50Hz 230V (220–240V) Compressor type DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø15.9 / ø9.5 Standard / Min. pipe length m 7.5 / 5 Max. pipe total length m 30 50 Maximum height difference m 30 30 30 Outer dimensions (H/W/D) mm 550/780/290 890/900/320 1340/900/320 Weight kg 40 44 68 99 Sound pressure level, Cooling/Heating*2 dB(A) 46/48 48/52 53/54 54/55 51/53 Operating range, Cooling/Heating °C -15~46 / -15~15 -15~43 / -15~15 Physical data Indoor unit (RAV-) SM406BT-E, SM406BTP-E* SM456BT-E, SM456BTP-E* SM566BT-E, SM566BTP-E* SM806BT-E, SM806BTP-E* SM1106BT-E, SM1106BTP-E* SM1406BT-E, SM1406BTP-E* SM1603DT-A Standard air flow (H/M/L) CFM 469/370/282 469/370/282 469/370/282 706/547/423 1235/970/741 1235/970/741 2047 External static pressure (factory setting) Pa 30 30 30 30 50 50 100 External static pressure-Standard (Upper-Lower) Pa 30(120-30) 30(120-30) 50(120-30) 100(50-250) Sound pressure level (H/M/L) dB(A) 33/29/25 33/29/25 33/29/25 34/30/26 40/36/33 40/36/33 50 Dimensions (H/W/D) mm 275/700/750 275/700/750 275/700/750 275/1000/750 275/1400/750 275/1400/750 380/1050/600 Weightkg 23 23 23 30 40 40 57 Out door unit Standard model (RAV-) SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E Heavy Anti-Corrosion protection model (RAV-) SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E Indoor unit (RAV-) SM566BT-E, SM566BTP-E* SM806BT-E, SM806BTP-E* SM1106BT-E, SM1106BTP-E* SM1406BT-E, SM1406BTP-E* SM1603DT-A Cooling*1 Capacity kW 5.0 6.7 10.0 12.1 14.3 Range, min-max kW 1.5-5.6 1.5-7.4 3.0-11.2 3.0-13.2 3.6-16.0 Power consumption kW 1.83 2.38 3.14 4.42 5.01 EER (Energy Efficiency Ratio) Capacity 100% 2.73 2.82 3.18 2.74 2.85 Capacity 80% 3.42 3.53 3.92 3.46 3.35 Capacity 50% 4.39 5.08 4.90 4.92 4.09 Heating*1 Capacity kW 5.3 7.7 11.2 12.8 16.0 Range, min-max kW 1.5-6.3 1.5-9.0 3.0-12.5 3.0-16.0 4.6-18.0 Power consumption kW 1.62 2.32 2.99 3.55 4.57 COP (Coefficient of Performance) Capacity 100% 3.27 3.32 3.75 3.61 3.50 Capacity 80% 3.69 3.87 4.15 4.11 3.68 Capacity 50% 4.57 5.07 5.09 4.89 3.91 Power supply 1-phase 50Hz 230V (220–240V) 1-phase 50Hz 230V (220–240V) Performance dataDI-Digital Inverter Performance data 1313
  • 14. RAV-SM***6BT(P)*-E Options SM566BT(P)*-E SM806BT(P)*-E SM1106BT(P)*-E, SM1406BT(P)*-E Model RAV- 765 1065 700 1000 1400 640 940 1340 750 1050 1450 A B DC 345 355 108 37 232 Refrigerant pipe connecting port (Liquid side) Refrigerant pipe connecting port (Gas side) Air outlet Ceiling Service door (Ceiling opening) Floor surface 25 25 D 100 or more 700 or more 2500 ormore 275 5or more 117.5 233 18 Drain pipe connecting port 23320570 20 s t 70or more A B C D E E 1465 700 500 700 (Unit:mm) F G F G 12.7 15.9 6.4 9.5 12.7 6.4 Space required for installation and servicing TCB-SF56C6BE TCB-SF80C6BE TCB-SF160C6BE Model SM566BT(P)*-E SM806BT(P)*-E Compatible SM1106BT(P)*-E, SM1406BT(P)*-E TCB-SF56C6BE TCB-SF80C6BE TCB-SF160C6BE (Unit:mm) TCB-SF56C6BE TCB-SF80C6BE TCB-SF160C6BE Hanging bolt pitch Unit external dimension External dimensions of flange A B C E 1/100 or more downward At the time of natural drainage Under air intake type Flexible drain hose (Accessory) Wires drawing-out port 650 14
  • 15. (Unit: mm) 20 10296 316 15 25 10 2525 20 60 276 (Inside) 274 (Inside) 757 (Inside) 845 (Inside)5252 0202 12 65 65 12 25 67.5 250 250 885 11 × 65 = 715 250 67.5 15 652652 271 807 11 × 65 = 715 4×60=240 300 324 15 25 60 4×60=240 10-Ø5 hole (Include in the other side) 24-Ø5 hole (Include in the other side) 24-Ø5 hole (Include in the other side) 8-Ø7 hole 10-Ø5 hole (Include in the other side)8-Ø7 hole Flange (Air outlet side) Flange (Air inlet side) Plug (Port for check and clean) Drain pipe Adhesive inhibited Check port 400 × 800 50 ormore 100 ormore1300ormore 200 200 ormore Service work space Drain trap 704 12 32 52 30 50 950(Boltpitch)(50)(50) (900)(95) 1050 965(Boltpitch)(35)(50) (36) (53) (72)(915) 664 25 48490 25 (111) 854 (85) 14514520 (30) 975042 380 271(28)81 600 2)006 5 () 25 ( wo l f r i Awo l f r i A Hung-up plate Refrigerant piping (5/8” (Ø15.88)) Refrigerant piping (3/8” (Ø9.52)) Refrigerant piping (3/8” (Ø9.52)) 3-M5 hole for drain pump kit Refrigerant piping (5/8” (Ø15.88)) Drain port (Outer diameter: Ø32) Electric parts box Drain port (Outer diameter: Ø32) RAV-SM 1403DT-A, RAV-SM 1603DT-A (Unit: mm) 20 10296 316 15 25 10 2525 20 60 276 (Inside) 274 (Inside) 757 (Inside) 845 (Inside)5252 0202 12 65 65 12 25 67.5 250 250 885 11 × 65 = 715 250 67.5 15 652652 271 807 11 × 65 = 715 4×60=240 300 324 15 25 60 4×60=240 10-Ø5 hole (Include in the other side) 24-Ø5 hole (Include in the other side) 24-Ø5 hole (Include in the other side) 8-Ø7 hole 10-Ø5 hole (Include in the other side)8-Ø7 hole Flange (Air outlet side) Flange (Air inlet side) Plug (Port for check and clean) Drain pipe Adhesive inhibited Check port 400 × 800 50 ormore 100 ormore1300ormore 200 200 ormoreService work space Drain trap 704 12 32 52 30 50 950(Boltpitch)(50)(50) (900)(95) 1050 965(Boltpitch)(35)(50) (36) (53) (72)(915) 664 25 48490 25 (111) 854 (85) 14514520 (30) 975042 380 271(28)81 600 2)006 5 () 25 ( wo l f r i Awo l f r i A Hung-up plate Refrigerant piping (5/8” (Ø15.88)) Refrigerant piping (3/8” (Ø9.52)) Refrigerant piping (3/8” (Ø9.52)) 3-M5 hole for drain pump kit Refrigerant piping (5/8” (Ø15.88)) Drain port (Outer diameter: Ø32) Electric parts box Drain port (Outer diameter: Ø32) RAV-SM 1403DT-A, RAV-SM 1603DT-A 1515
  • 16. rav-sm∗∗∗2dt-E Design flexibility Compatible with external static pressures up to 196 Pa. Concealed Duct High Static Pressure type Satisfies all your design needs Concealed Duct High Static Pressure type DI BIG . Comfort Inverter Allows step-less regulation of the air-conditioner’s power,which reduces energy consumption and improves comfort. . Automatic Air Volume control Depending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low. . Hot Start When using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room. Operativity Filter Sign Automatic displays on the remote controller say when to perform maintenance for the indoor unit filter. Limit Timer Uses a 168-hour timer with three modes - “ON timer”, “OFF timer” and “Repeat OFF timer”. Installation Cooler Compatible with an Outdoor Temperature of -15 ° C Stable cooler operation is possible when the outdoor temperature is as low as -15 ° C. 3-steps-switchable static pressure Large air volume, Duct high static pressure type is most suitable for the large rooms. Long-life filters fitted as standard. Can be equipped with the following options: • high-efficiency filter (65, 90) • drain pump kit (optional) Low Middle High External static pressure (Pa) 68.6 137.0 196.0 Construction characteristics The flexible duct is accessible. Constant temperature setting is possible in large rooms or factories. Easy service and installation. Enable to maintain the blower section from unit side for maintenance and repair. Enable to select auto restart operation (set from wired remote controller) *Factory setting : 137Pa Dry Gradually dehumidifies the room to create even greater comfort. 16
  • 17. MML-AP***4NH-EOutdoor unit (RAV-) SM2804AT8-E Indoor unit (RAV-) SM2802DT-E Cooling*1 Capacity kW 23.0 Range, min-max kW 9.8-27.0 Power consumption kW 8.75 EER (Energy Efficiency Ratio) Capacity 100% 2.63 Capacity 80% 3.24 Capacity 50% 4.49 Heating*1 Capacity kW 27.0 Range, min-max kW 9.8-31.5 Power consumption kW 8.15 COP (Coefficient of Performance) Capacity 100% 3.31 Capacity 80% 3.80 Capacity 50% 4.77 Power supply 3-phase 50Hz 380– 415V DI BIG Performance data Physical data Indoor unit (RAV-) SM2802DT-E Standard air flow at 137Pa/ (at Mid tap) CFM 2470 External static pressure (H/M/L) Pa 196/137/68.6 Sound pressure level (H/M/L) dB(A) 55 Dimensions (H/W/D) mm 470/1380/1250 Weightkg 160 Physical data Equivalent HP 10HP Outdoor unit (RAV-) SM2804AT8-E Power supply 3-phase 50Hz 380– 415V Compressor type DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø28.6 / ø12.7 Min. pipe length m 7.5 Max. pipe total length m 70 Maximum height difference m 30 Outer dimensions (H/W/D) mm 1540/900/320 Weight kg 134 Sound pressure level, Cooling/Heating*2 dB(A) 57/58 Operating range, Cooling/Heating °C -15~46 / -20~15 RAV-SM***2DT-E Filter chamber TCB-FCY100DE TCB-PF3DE Drain pump kit TCB-DP32DE TCB-UFM3DE TCB-UFH7DE Options (4-12 × 92) 600 1288 1328 624 698 1250 250 37065 250 35 250 22 46 250 002051 31 200 250 3540629 470 45 250 250 250 1260 1380100 65 1000 200 190 190 Space required for installation and serving Hole for hanging bolt Service space Refrigerant pipe connecting port (Gas side Brazed) ormore * Check port Service space Service space (Hanging bolt mounting pitch) (Hangingboltmountingpitch) Air discharge port Screw hole for duct mounting (10-M6) Air suction port Refrigerant pipe connecting port (Liquid side 12.7 Flared)* Drain pipe connecting port (V25) Taper screw for R1,25.4 pipes Electric parts box Power supply/communication piping port (Ø26) (Under electric parts box) Screw hole for duct mounting (10-M6) (Unit:mm) ormore (Unit:mm) 22.2 12.7 Diameter of pipe connecting port Diameter of pipe connecting pipe Gas sideLiquid side Gas sideLiquid side 12.7 28.6 1717
  • 18. 18
  • 19. Indoor unit type Outdoor unit name (RAV-) Indoor unit name (RAV-) HP Capacity EER Rated (kW) min-max (kW) Power consumption (kW) 100% 80% 50% 4-Way Cassette SM1104AT(J)P-E SM564UTP-E 4 10.0 3.0-11.2 3.02 3.31 4.08 5.10 SM1404AT(J)P-E SM804UTP-E 5 12.0 3.0-13.2 4.29 2.80 3.53 5.00 SM1603AT(Z)(ZG)-E SM804UTP-E 6 14.0 3.0-16.0 4.49 3.12 3.98 4.86 Standard Duct SM1104AT(J)P-E SM566BTP-E* 4 10.0 3.0-11.2 3.14 3.18 3.92 4.90 SM1404AT(J)P-E SM806BTP-E* 5 12.1 3.0-13.2 4.42 2.74 3.46 4.92 SM1603AT(Z)(ZG)-E SM806BTP-E* 6 14.0 3.0-16.0 5.13 2.73 3.48 4.24 Twin system : DI-Digital Inverter 1-phase Indoor unit type Outdoor unit name (RAV-) Indoor unit name (RAV-) HP Capacity COP Rated (kW) min-max (kW) Power consumption (kW) 100% 80% 50% 4-Way Cassette SM1104AT(J)P-E SM564UTP-E 4 11.2 3.0-13.0 2.93 3.82 4.23 5.19 SM1404AT(J)P-E SM804UTP-E 5 12.8 3.0-16.0 3.40 3.76 4.30 5.12 SM1603AT(Z)(ZG)-E SM804UTP-E 6 16.0 3.0-18.0 4.43 3.61 4.59 4.91 Standard Duct SM1104AT(J)P-E SM566BTP-E* 4 11.2 3.0-12.5 2.99 3.75 4.15 5.09 SM1404AT(J)P-E SM806BTP-E* 5 12.8 3.0-16.0 3.55 3.61 4.11 4.89 SM1603AT(Z)(ZG)-E SM806BTP-E* 6 16.0 3.0-18.0 4.69 3.41 4.04 4.32 Twin system : DI-Digital Inverter 1-phase Cooling Heating Indoor unit type Outdoor unit name (RAV-) Indoor unit name (RAV-) HP Capacity EER Rated (kW) min-max (kW) Power consumption (kW) 100% 80% 50% 4-Way Cassette SM2804AT8(Z)(ZG)-E SM1404UTP-E 10 23.0 9.8-27.0 8.19 2.81 3.46 4.79 Standard Duct SM2804AT8(Z)(ZG)-E SM1406BTP-E* 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62 Twin system : DI Big 3-phase Indoor unit type Outdoor unit name (RAV-) Indoor unit name (RAV-) HP Capacity COP Rated (kW) min-max (kW) Power consumption (kW) 100% 80% 50% 4-Way Cassette SM2804AT8(Z)(ZG)-E SM1404UTP-E 10 27.0 9.8-31.5 7.48 3.61 4.15 5.21 Standard Duct SM2804AT8(Z)(ZG)-E SM1406BTP-E* 10 27.0 9.8-31.5 7.92 3.41 3.91 4.91 Twin system : DI Big 3-phase Cooling Heating Twin, Triple and Double twin system 1919
  • 20. Twin, Triple and Double twin system Indoor unit type Outdoor unit name (RAV-) Indoor unit name (RAV-) HP Capacity COP Rated (kW) min-max (kW) Power consumption (kW) 100% 80% 50% 4-Way Cassette SM2804AT8(ZG)-E SM804UTP-E 10 27.0 9.8-31.5 7.48 3.61 4.15 5.21 Standard Duct SM2804AT8(ZG)-E SM806BTP-E 10 27.0 9.8-31.5 7.92 3.41 3.91 4.91 Triple system : DI Big 3-phase Heating Indoor unit type Outdoor unit name (RAV-) Indoor unit name (RAV-) HP Capacity EER Rated (kW) min-max (kW) Power consumption (kW) 100% 80% 50% 4-Way Cassette SM2804AT8(ZG)-E SM804UTP-E 10 23.0 9.8-27.0 8.19 2.81 3.46 4.79 Standard Duct SM2804AT8(ZG)-E SM806BTP-E 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62 Triple system : DI Big 3-phase Cooling Indoor unit type Outdoor unit name (RAV-) Indoor unit name (RAV-) HP Capacity COP Rated (kW) min-max (kW) Power consumption (kW) 100% 80% 50% 4-Way Cassette SM1603AT(Z)(ZG)-E SM564UTP-E 6 16.0 3.0-18.0 4.43 3.61 4.59 4.91 Standard Duct SM1603AT(Z)(ZG)-E SM566BTP-E* 6 16.0 3.0-18.0 4.69 3.41 4.04 4.32 Triple system : DI-Digital Inverter 1-phase Heating Indoor unit type Outdoor unit name (RAV-) Indoor unit name (RAV-) HP Capacity EER Rated (kW) min-max (kW) Power consumption (kW) 100% 80% 50% 4-Way Cassette SM1603AT(Z)(ZG)-E SM564UTP-E 6 14.0 3.0-16.0 4.49 3.12 3.98 4.86 Standard Duct SM1603AT(Z)(ZG)-E SM566BTP-E* 6 14.0 3.0-16.0 5.13 2.73 3.48 4.24 Triple system : DI-Digital Inverter 1-phase Cooling Indoor unit type Outdoor unit name (RAV-) Indoor unit name (RAV-) HP Capacity EER Rated (kW) min-max (kW) Power consumption (kW) 100% 80% 50% 4-Way Cassette SM2804AT8(ZG)-E SM804UTP-E 10 23.0 9.8-27.0 8.19 2.81 3.46 4.79 Standard Duct SM2804AT8(ZG)-E SM566BTP-E* 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62 Double twin system : DI Big 3-phase Cooling Indoor unit type Outdoor unit name (RAV-) Indoor unit name (RAV-) HP Capacity COP Rated (kW) min-max (kW) Power consumption (kW) 100% 80% 50% 4-Way Cassette SM2804AT8(ZG)-E SM804UTP-E 10 27.0 9.8-31.5 7.48 3.61 4.15 5.21 Standard Duct SM2804AT8(ZG)-E SM566BTP-E* 10 27.0 9.8-31.5 7.92 3.41 3.91 4.91 Double twin system : DI Big 3-phase Heating 20
  • 21. Indoor unit Parts Name Model Name Applied Model Remarks 4-Way Cassette type Ceiling panel RBC-U31PGP(W)-E, RBC-U31PGP(WS)-E RAV-SM***4UTP-E Fresh air inlet box TCB-GB1602UE Use with TCB-GFC1602UE Fresh air filter chamber TCB-GFC1602UE Auxiliary fresh air flange TCB-FF101URE2 Spacer for height adjustment TCB-SP1602UE Air discharge direction kit TCB-BC1602UE Standard Duct type Spigot shaped flange TCB-SF80C6BE RAV-SM806BTP-E* TCB-SF160C6BE RAV-SM1106BTP-E* RAV-SM1406BTP-E* Concealed Duct High Static Pressure type High-efficiency filter 65 TCB-UFM3DE RAV-SM***2DT-E Use with TCB-FCY100DEHigh-efficiency filter 90 TCB-UFH7DE Long life prefilter TCB-PF3DE Filter chamber TCB-FCY100DE Drain pump kit TCB-DP32DE Indoor unit accessories Parts Name Model Name Type Branch kit RBC-TWP30E Digital Inverter 1-phase model RBC-TWP50E RBC-TWP101E 1:2 Twin system of Dl Big model RBC-TRP100E 1:3 Digital Inverter 1-phase model and DI Big model RBC-DTWP101E 1:4 Double twin system of DI Big model Digital Inverter - Controllers Accessories Parts Name Model Name Applied Model Features Wired remote controller RBC-AMT32E All indoor units Standard type RBC-AMS41E All indoor units Remote controller with weekly timer RBC-AMS51E-ES/-EN All indoor units Remote controller with LCD display with backlight Simple wired remote controller RBC-AS41E All indoor units With Simplified control Wireless remote controller kits RBC-AX32U(W)/(WS)-E 4-Way Cassette type Integral receiver type TCB-AX32E2 All indoor units Standalone receiver type Remote controller kits TCB-EXS21TLE Use with wired remote controller Remote controller with schedule timer TCB-CC163TLE2 Used with wired remote controller / Central remote controller On-Off controller combined with the weekly timer TCB-SC642TLE2 All indoor units Central remote controller BMS-CM1280TLE All indoor units Compliant manager TCC-Link* TCB-PCNT30TLE2 All indoor units except High-wall type Use with Remote controller kit Indoor unit controllers * : TCC-Link Adaptor for Digital Inverter units. 2121
  • 22. Standard Remote controller RBC-AMT32E Standard wired remote controller can be connected to a single indoor unit or a group of up to 8 indoor units. Power save operation limits the greatest current value.The remote controller allows error to be displayed while the protective device works or a error occurs. Remote controller with weekly timer (7-day timer function) RBC-AMS41E Wired remote controller with clock display and a built in 7-day timer function, possible to program 8 functions for each day of the week. *The following items can be set in program: operation time, operation start/stop, operation mode, temperature setting, restriction on button operation Lite-Vision plus Remote Controller RBC-AMS51E-ES RBC-AMS51E-EN Wired remote controller with a built in 7-day timer-featuring a new multi-language, LCD display with backlight, energy saving options and a return back function. • Possibility to set and display the room name to easily set-up and monitor the working parameter. • New modern and desirable controller design with menu driven display. • Save mode by schedule timer to optimise energy consumption. • Room temperature display always available. • Two“Hot Keys”(F1, F2) for easy operation of air conditioner functions. • Easy to read layout including display of indoor unit model name and serial number. • Built-in backup power. Settings are kept in memory up to 72 hours in case of power failure. • Remote TA sensor available in controller. • Can be connected to a single indoor unit or a group of up to 8 indoor units. Simple wired remote controller can be connected to a single indoor unit or a group of up to 8 indoor units. • Start/Stop • Temperature setting • Air flow changing • Check code display Simple wired remote controller RBC-AS41E Wireless remote controller kit • Start/Stop •Changing mode •Temperature setting • Air flow changing • Timer function Either“ON”time or“OFF”time or “CYCLIC”can be set how many 30 min. later ON or OFF is operated. • Control by 2 remote controllers is available. Two wireless remote controllers can operate one indoor unit. The indoor unit can then be operated separately from the two different locations. • Check code display RBC-AX32U(W)/(WS)-E Integral receiver (For 4-way cassette) TCB-AX32E2 Sensor unit; Stand alone receiver (For 4-way cassette), (Duct type) Schedule timer TCB-EXS21TLE Central remote controller BMS-CM1280TLE • Schedule timer mode – 6 programmings per day – Enabling 8 groups to be programmed – A maximum of 64 indoor units can be controlled – A maximum of 100 hours back-up power supply • Weekly timer mode – 7 types of weekly schedule and 3 programmings per day ON-OFF controller TCB-CC163TLE2 • Individual control of up to 16 indoor units. • Setting of simultaneous ON/OFF 3 times per day combined with the weekly timer. Central remote controller TCB-SC642TLE2 • Individual control for max. 64 indoor units divided into 1 to 4 zone (Up to 16 indoor units for each zone) • Up to 16 outdoor header units are connectable • 4 types of central control settings to inhibit individual operation by remote controller can be selected • Usable with other central control devices (Max. 10 devices in one control circuit) • Two control mode selectivity (Central controller mode ) Remote controller mode • Setting of simultaneous ON/OFF 3 times per day combined with the weekly timer. • Operation Individual operation of 128 indoor units available Return Back Operation Weekly Schedule Operation* (ON/OFF) * Schedule timer necessary • Monitoring Zone setting (64 zones x 2) Individual unit operation mode operation restriction Alarm display Control input Status output Remote controllers 22
  • 23. Discharge guide mounting hole (4-dia.4.5 embossing) charge port Earth terminal Discharge guard B legs A legs Drain hole (Longholepitch Foranchorbolt) (2-dia. 20x88 long hole) Drain hole(dia. 25) 2-dia. 11-14 U-shape hole (For dia.8-10 anchor bolts) Refrigerant pipe connecting port (dia. 12.7 flare at gas side) Refrigerant pipe connecting port (dia. 6.4 flare at liquid side) 8-dia. 6 hole 2-dia. 11xL14 long hole For fixing outdoor unit (For dia. 8-10 anchor bolts) dia.holepitch 8 35 52 550 21 6 69.5 147 32 500 780 71 25 22 257483 108 600 90 54108 125 157 79 31 143 145 21 449 483 30 60 30 27 290 306 320 137 93 342 54 dia. 11x14 U-shape hole Product external line Details of B legs 2-dia. hole R15 600 38 54 320 R15 2-dia. 6 hole Product external line Details of A legs dia. 11x14 U-shape hole 600 54 38 11 320 2-dia. 11x14 U-shape hples (For dia. 8-10 anchor bolt) Suction port or more or more or more Discharge port Discharge port 2-dia. 11x14 long hole (For dia.8-10 anchor bolt) or more 600 300 500 150 320 (Unit: mm) Space required for installation and servicing (Unit: mm) DI Digital Inverter 2-3HP : Outdoor unit drawings 2323
  • 24. DI Digital Inverter 4HP and 5HP: Outdoor unit drawings Mounting bolt hole (dia. 12x17 long hole) Details ofA legs Mounting bolt (dia. 12x17 U-shape hole) Details of B legs 40 40 12 17.536517.5 Drain hole(dia. 20x88) 74118128 Air inlet port 380 2006 0 Air inlet port Air outlet port Drain hole(dia. 25) B legs 46 34 170 75 70383 150 600 A legs 39 96 320 30 2 1 890 24 400 151 8018 9555 94 2 1 255 247 155 1880 135 900 55052 Refrigerant pipe connecting port (dia. 9.5 flare at liquid side) Refrigerant pipe connecting port (dia. 15.9 flare at gas side) 9555 17817817860 327 68 518 83 7 765 9555 12 64 1 1 2 Knockout for downward piping Z views Refrigerant piping hole Indoor/Outdoor unit connecting wire inlet hole Name Note Power supply inlet holed ia. 38 Knockout hole 581 534 148 165 (Unit: mm) 24
  • 25. DI Digital Inverter 6HP : Outdoor unit drawings Name Note Refrigerant piping hole Indoor/Outdoor unit connecting wire inlet hole —— Power supply inlet hole Ø38 Kockout hole 1 2 36517.5 74 17.5 128 46 48 40 40 54 34 170 118 380 383 150 600 70 96 39 12 75 200 60 Air inlet port Air inlet port Air outlet port Drain hole (Ø28 × 88) Drain hole (Ø25) Mounting bolt hole (Ø12 × 17 long hole) Mounting bolt hole (Ø12 × 17 U-shape hole) B legs Details of A legs Details of B legs A legs 5595 21 64 1 657 83 7 Knockout for downward piping ws 655 12153453485 5595 55 94 95 24 1340 155 605 613 4710875185 360 900 550 60 151531815 400 08810887187 11 8 30 52 320 Refrigerant pipe connecting port Refrigerant pipe connecting port (Ø15.9 flare at gas side) 2 1 2 1 86 178 327 Z views (Unit: mm) 2525
  • 26. DI Big 10HP: Outdoor unit drawings Knockout (for drain) Drain hole (Ø28 x 88 bearing hole) Drain hole (Ø25 bearing hole) B legs A legs Air inlet port Knockout (for drain) Air outlet Mounting bolt hole (Ø12 x 17 long hole) Mounting bolt hole (Ø12 x 17 U-shaped hole) Details of A legs Details of B legs Refrigerant pipe connecting port (liquid side) Refrigerant pipe connecting port (gas side) Z views Knockout for downward piping Air inlet port Since the connection diameter of the ball valve in the outdoor unit main body is Ø19.1, use the attached coupling pipe when performing maintenance. etoNemaN a Refrigerant piping hole Indoor/Outdoor unit connecting wire inlet hole — b Power supply inlet holeØ 38 Knockout hole Piping Connection Aperture Radius Connection Piping Radius LiquidG as LiquidG as 12.71 9.1 12.7 28.6 * * (Unit: mm) 26
  • 27. Precautions for using air conditioners Concerning the automatic defrosting unit When the outdoor air temperature drops, frost may form on the heat exchanger of the outdoor unit. In such cases, the automatic defrosting unit will be activated, and it will take 5 to 8 minutes for the heating operation to be restored. Concerning the air conditioner's operating conditions and their selection (1) Avoid using the air conditioner in the following locations. • Locations with acidic or alkaline atmospheres (locations at which highly acidic or alkaline air is directly drawn in, such as in hot springs areas from which sulfur gases are given off, or where chemicals, vinegar, exhaust air from burners, etc., are given off) The heat exchangers and other parts may become corroded. • Locations with atmospheres filled with coolant or other machine oil or steam exhaust (such as at food preparation factories or machine plants). The heat exchangers may corrode; frost may form as a result of heat exchanger malfunction; air conditioner operating performance may be compromised or condensation may form as a result of clogged filters; plastic parts may incur damage; heat-insulation materials may become separated, etc. (2) Before using an air conditioner in any of the following locations, consult with your dealer or a qualified contractor. • Locations where vapors from edible oils are given off (such as in bakeries or kitchens and restaurants that use edible oils) ...The air conditioner's operating performance may be compromised or condensation may form as a result of clogged filters, and the plastic parts may incur damage. In line with the prevailing conditions, take countermeasures such as tailoring the installation conditions in accordance with the conditions, using air conditioners designed for kitchens or oil guard filters, etc. • Locations with disinfectant-induced chlorine atmospheres (water tanks, etc.) The metal parts in the heat exchangers, motors, etc., may become corroded. • Locations with high salinity (coastal areas, etc.) Corrosion may occur so use outdoor units specifically designed to withstand exposure to salt. • Locations where power is supplied from independent power generators. The power line frequency and/or voltage may fluctuate, possibly causing the air conditioner to malfunction. • Locations where high frequencies or electrical noise is generated (from high-frequency welders used for vinyl welding and processing, high-frequency therapeutic devices used for thermotherapy, etc.) The electronic components may be adversely affected, possibly causing the air conditioner to malfunction. • Locations where electronic equipment is installed. Electrical noise may adversely affect the operation of the electronic equipment. (3) Concerning use in locations with high ceilings • In locations with high ceilings, use of circulators for improving the temperature distribution during heating is recommended. (4) Concerning use in high-humidity environments • When the ceiling-recessed type of indoor unit is installed in a location, such as those described below, and it is very hot and humid inside the ceiling, condensation may form on the external surfaces of the indoor unit and drip down. In such cases, add external heat-insulating materials. – Locations such as food preparation sites in which the areas above the ceilings are hot and humid – Locations in which outside air is drawn in and routed above the ceiling – Above ceilings with a slate roof or tiled roof overhead (5) Even when an air conditioner is shut down, it will still consume a small amount of power to protect the unit. If the air conditioner will not be used for a prolonged period, turn OFF the main switch (ground fault circuit breaker). However, before the unit is to be used again, turn ON the main switch (ground fault circuit breaker) for at least 12 hours in order to prevent trouble. SAFETY PRECAUTIONS For operation: • Before use, read through the operating instructions to ensure proper use. Concerning the purpose for which the air conditioners are to be used • The air conditioners presented in this catalogue are air conditioning/heating units to be used solely by general consumers. – Do not use these air conditioners for special applications such as for the storage of food items, animals, plants, precision machines or works of art. Doing so may degrade the quality of the items. – Do not use these air conditioners for air-conditioning applications in vehicles or ships. Doing so may cause water and/or power leakages. Installation and the use of refrigerants not specified by Toshiba Carrier Corporation Toshiba refrigeration and air-conditioning units are designed and manufactured on the assumption that the product is used with a specific refrigerant suitable for each unit. We have recently seen some cases where the type of refrigerant used is different from the one originally installed in the product. Such actions may cause mechanical defects, malfunctions, failures and in some cases result in a serious safety issue. Therefore do not install any refrigerant other than the one specified by Toshiba Carrier Corporation for its respective products. The type of the refrigerant used for each of our products is shown in the accompanying owners manual, or on the product label attached on the product itself. Toshiba Carrier Corporation shall not assume any liability for failures, malfunctions or safety in its products if the refrigerant used is different from the one specified. 2727