SlideShare a Scribd company logo
1 of 65
CONDITION SURVEY &
NON-DESTRUCTIVE
EVALUATION
NON-DESTRUCTIVE EVALUATION
TESTS
NON DESTRUCTIVE EVALUATION TESTS :
• The term ‘non destructive’ is used to indicate that it does not
impair the intended performance of the structural member
being tested/investigated.
• The non- destructive evaluation have been broadly classified
under two broad categories viz ‘in-situ field test’ and
‘laboratory test’. These tests have been put under five
categories depending on the purpose of test as under :
1. In-situ Concrete Strength
2. Chemical Attack
3. Corrosion Activity
4. Fire Damage
5. Structural Integrity/Soundness
Sl No TestMethod Details
A. Insitu Concrete Strength:
1 Rebound Hammer Test A qualitative field test method to measure surface
hardnessof concrete
2 Ultrasonic Pulse Velocity Aqualitativefield testbymeasurement ofUltrasonicPulse
Velocity (UPV)
3 Windsor Probe A qualitative field test for assessment of near surface
strength of concrete
4 Capo/Pull out test -do-
5 a. Core cutting/ sampling
b. Lab Testing of Cores Fieldcum lab test method for assessing qualityof concrete
as under:
- strength
- density
- texture
6. Load Test
- permeability
A field test for assessing the load carrying capacity within
the limits of elastic deformations
B. Chemical Attack
1 Carbonation Test A field/lab test for assessment of pH ofconcrete and depth
of carbonation
2 Chloride Test A field/lab Test for assessment of total water/acid soluble
chloride contents
3 Sulphate Test A Lab Test for assessment of total acid/water soluble
sulphate contents of concrete
C. Corrosion Potential Assessment
1 Cover-Meter / Profo-meter A field method for measuring
measurement -thickness of cover concrete
(In-situ Test) -reinforcement diameter
-reinforcement spacing.
2 Half Cell Method A field method for Measuring/ plotting corrosion potential
for assessing probability of corrosion
3 Resistivity Meter A field method for assessing electrical resistivity of
concrete to determine its corrosion resistance
4 Permeability
a. Water
b. Air A field/Lab method for assessment of in-situ permeability
of concrete due to water and air.
D. Fire Damage Assessment
Thermo-Gravimetric A laboratory test for assessment of temperature
Analysis (TGA) range to which concrete was subjected to
Differential Thermal A laboratory Test for assessment of qualitative
Analysis (DTA) & quantitative composition of sample of concrete
X-ray Diffraction (XRD) To determine the extent of deterioration in concrete
subjected to fire
E. Structural Integrity/Soundness Assessment
1. Ultra-sonic Pulse velocity A field method for determination of discontinuities,
cracks and depth of cracks
2 Radiography For taking photographs showing details of inside of a
concrete member, where other NDEmethods arenotsuitable
3 Impact Echo Test A field/laboratory test method to detect hidden damage
And its extent.
Rebound Hammer Test :
• Hammer is also called Schmidt’s Hammer test.
• When the plunger of rebound hammer is pressed against the surface of
concrete, a spring controlled mass with a constant energy is made to hit
concrete surface to rebound back.
• The extent of rebound, which is a measure of surface hardness, is
measured on a graduated scale.
• This measured value is designated as Rebound Number (a rebound index).
A concrete with low strength and low stiffness will absorb more energy to
yield in a lower rebound value.
• IS 13311 Pt-2-1992 as well as BS: 6089-81 and BS: 1881:Pt-202 explains the
standard procedure for test and correlation between concrete cube crushing
strength and rebound number. The results are significantly affected by the
following factors :
A. Mix characteristics :
1. Cement type,
2. Cement Content,
3. Coarse aggregate type
B. Angle of Inclination of direction of hammer with reference to horizontal.
A. Member Characteristics,
1. Mass,
2. Compaction,
3. Surface type,
4. Age, rate of hardening and curing type,
5. Surface carbonation,
6. Moisture Condition,
7. Stress state and temperature.
Strength Assessment
• This test is conducted to assess the relative strength of concrete based on
the hardness at or near its exposed surface. Carrying of periodic
calibration of rebound hammer using standard anvil is desirable.
• However for new concrete construction, rebound hammer is calibrated on
concrete test cubes for a given source of constituent materials (viz.
cement, sand and stone aggregate), this calibration data can be used with
reasonable accuracy in arriving at equivalent in-situ cube strength of
relatively new concrete ( i.e. not more than three months old concrete).
• This calibration exercise may be carried out in a concrete lab by casting
cubes of designed mix and testing these under controlled condition with
rebound hammer as well as test to destruction in compression.
Strength Assessment
• Calibration graphs then can be drawn. Large number of readings are
desirable to reduce the effects of variability in readings due to various
localized as well as instrument factors. This method may give highly
erroneous results for concrete whose surface is exposed to atmosphere
for longer periods say more than three months. This is due to hardening of
concrete surface due to carbonation, which may cause overestimation as
much as 50% for old structure.
• Hence Strength assessment by Rebound Hammer Test should generally
be restricted to relatively new structures only.
Survey of Weak &
delaminating Concrete
• As the test requires a flat surface and large number of readings to reduce
variability, this test is not generally suitable for use on spalled concrete
surfaces of distressed structures.
• However, comparison of Rebound numbers, which indicate the near
surface hardness of the concrete, will help to identify relative surface
weaknesses in cover concrete and also can be used to determine the
relative compressive strength of concrete.
• Locations possessing very low rebound numbers will be identified as weak
surface concrete and such locations will be identified for further
investigations like corrosion distress, fire damage and/or any other reason
including original construction defects of concrete.
• Locations possessing very low rebound numbers will be identified as weak
surface concrete and such locations will be identified for further investigations
like corrosion distress, fire damage and/or any other reason including original
construction defects of concrete. This survey is to be carried out on each
identified member in a systematic way by dividing the member into well-
defined grid points.
• The grid matrix should have a spacing of approximately 300mmx 300mm.
Table 3.8 gives guidelines for qualitative interpretation of rebound hammer
test results with reference to quality.
Ultrasonic Pulse Velocity (UPV) test
• Ultrasonic scanning is a recognized non-destructive evaluation test to
qualitatively assess the homogeneity and integrity of concrete. With this
technique, following can be assessed.
1. Qualitative assessment of strength of concrete, its gradation in different
locations of structural members and plotting the same
2. Any discontinuity in cross section like cracks, cover concrete delamination
etc
3. Depth of surface cracks.
UPV
• This test essentially consists of measuring travel time, ‘T’ of ultrasonic
pulse of 50-54 kHz, produced by an electro-acoustical transducer, held in
contact with one surface of the concrete member under test and receiving
the same by a similar transducer in contact with the surface at the other
end.
• With the path length, ‘L’ (i.e. the distance between the two probes) and
time of travel, T the pulse velocity (V = L/T) is calculated (fig 3.8).
• Higher the elastic modulus, density and integrity of the concrete, higher is
the pulse velocity . The ultrasonic pulse velocity depends on the density
and elastic properties of the material being tested.
• Though, pulse velocity is related with crushing strength of concrete, yet no
statistical correlation can be applied.
• The pulse velocity in concrete may be influenced by
1. Path length
2. Lateral dimensions of the specimen tested.
3. Presence of reinforcing steel
4. Moisture content of the concrete.
• The influence of path length will be negligible provided it is not less than 100
mm when 20 mm size aggregate is used or less than 150 mm for 40 mm size
aggregate. Pulse velocity will not be influenced by the shape of the specimen,
provided its least lateral dimension (i.e. its dimension measured at right
angles to the pulse path ) is not less than the wavelength of the pulse
vibrations .
• For pulse of 50 Hz frequency, this corresponds to a least lateral dimension of
about 80 mm. The velocity of pulses in a steel bar is generally higher than
they are in concrete .
• For this reason, pulse velocity measurements made in the vicinity of
reinforcing steel may be high and not representative of the concrete .
• The influence of the reinforcement is generally small if the bars run in a
direction at right angles to the pulse path and the quantity of steel is small
in relation to the path length .
• The moisture content of concrete can have a small but significant influence
on the pulse velocity.
• In general, the velocity is increased with increased moisture content, the
influence being more marked for lower quality concrete.
• Measurement of pulse velocities at points on a regular grid on the surface of
a concrete structure provides a reliable method of assessing the
homogeneity of the concrete . The size of the grid chosen will depend on the
size of the structure and the amount of variability encountered.
Detection of defects
• When an ultrasonic pulse traveling through concrete meets a concrete-air-
interface, there is a negligible transmission of energy across this interface
so that any air-filled crack or void lying directly between the transducers
will obstruct the direct beam of ultrasound when the void has a projected
area larger than the area of transducer faces.
• The first pulse to arrive at the receiving transducer will have been
diffracted around the periphery of the defect and the time will be longer
than in similar concrete with no defect.
Estimating the depth of cracks.
• An estimate of the depth of a crack visible at the surface can be obtained
by measuring the transit times across the crack for two different
arrangements of the transducers placed on the surface.
• One suitable arrangement is one in which the transmitting and receiving
transducers are placed on opposite sides of the crack and distant from it.
Two values of ‘x’ are chosen, one being twice that of the other, and the
transmit times corresponding to these are measured .
• An equation may be derived by assuming that the plane of the crack is
perpendicular to the concrete surface and that the concrete in the vicinity
of the crack is of reasonably uniform quality . It is important that the
distance ‘x’ be measured accurately and that very good coupling is
developed between the transducers and the concrete surface. The method
is valid provided the crack is not filled with water.
Penetration Resistance
(‘Windsor Probe’)
• This technique offers a means of determining relative strengths of
concrete in the same structure or relative strength of different structures.
Because of the nature of equipment, it can not, and should not be
expected to yield absolute values of strength. ASTM C-803 gives this
standard test method titled, “ penetration resistance of hardened
concrete”.
• Windsor Probe’, as commercially known, is penetration resistance
measurement equipment, which consists of a gun powder actuated driver,
hardened alloy rod probe, loaded cartridges, a depth gauge and other
related accessories.
• In this technique, a gunpowder-actuated driver is used to fire a hardened alloy
probe into the concrete.
• During testing, it is the exposed length of probe, which is measured by a
calibration depth gauge.
• But, it is preferable to express the coefficient of variation in terms of the
depth of penetration as the fundamental relation is between concrete
strength and penetration depth.
• The probe shown in fig. No. 3.9 has a diameter of 6.3 mm, length of 73 mm,
and conical point at the tip . The rear of the probe is threaded and screwed
into a probe-driving head, which is 12.6 mm in diameter and fits snugly along
with a rubber washer into the bore of the driver.
• As the probe penetrates into the concrete, test results are usually not affected
by local surface conditions, such as texture and moisture content. However,
damage in the form of cracking may be caused to slender members. A
minimum edge distance and member thickness of 150 mm is required. It is
important to leave 50mm distance from the reinforcements present in the
member since the presence of the reinforcing bars within the zone of
influence of the penetrating probe affects the penetration depth.
Fig.-3.9 Windsor Probe
Pullout (LOK) Test
• The fundamental principle behind pull out testing with LOK-test and CAPO
test is that test equipment designed to a specific geometry will produce
results (pull-out forces ) that closely correlate to the compressive strength
of concrete.
• This correlation is achieved by measuring the force required to pull a steel
disc or ring, embedded in fresh concrete, against a circular counter
pressure placed on the concrete surface concentric with the disc/ring.
• For hardened concrete, an expandable steel ring is used instead. This ring
expands to fit a specially drilled hole and routed recess in the concrete.
The first method, shown in figure 3.13 using the cast in steel disc, is called
LOK test.
Fig.-3.13 LOK test insert
• The second method , shown in figure 3.14 using expandable ring, is called CAPO-
test (i.e. Cut And Pull Out Test) The diameter of both the disc and ring is 25mm.
The distance to the concrete surface is also 25mm. The inner diameter of the
counter pressure is 55mm.
Fig.-3.14 CAPO test testing principle
• The major limitation with this test is that it requires special care at the time of placement of inserts
to minimise air voids below disc besides a pre-planned usage.
• Pull out tests are used to:
i. Determine in-situ compressive strength of the concrete.
ii. Ascertain the strength of concrete for carrying out post- tensioning
operations.
iii. Determine the time for removal of forms and shores based on actual in-situ
strength of the structure.
iv. Terminate curing based on in-situ strength of the structure.
• Here item no (i) only are of relevance for residual strength assessment of old &
distressed structures. It can be also used for testing repaired concrete sections.
These tests are divided under the following two categories:
1. Embedding an insert into the fresh concrete while casting and then pulling
out with a jack (LOK test- LOK meaning “punch”) after hardening after a
specified period.
2. Insert fixed into a hole drilled into the hardened concrete and then pulling
out with a jack (CAPO test- cut and pull out).This second method offers
greater flexibility for conducting in-situ tests on hardened concrete of
existing structures and is explained above in detail.
• After the concrete has fractured by this test, the holes left in the surface are
first cleaned of the dust by a blower . It is then primed with epoxy glue and the
hole is filled with a polymer- modified mortar immediately thereafter and the
surface is smoothened.
• Core Sampling and Testing
• While rebound hammer, Capo/Pullout, Windsor probe and ultrasonic pulse
velocity tests give indirect evidence of concrete quality, a more direct
assessment on strength can be made by core sampling and testing. Cores are
usually cut by means of a rotary cutting tool with diamond bits. In this manner,
a cylindrical specimen is obtained, usually with its ends being uneven, parallel
and square and sometimes with embedded pieces of reinforcement. The cores
are visually described and photographed, giving specific attention to
compaction, distribution of aggregate, presence of steel etc. The core should
then be soaked in water, capped with molten sulpher to make its ends plane,
parallel, at right angle and then tested in compression in a moist condition as
per BS 1881: Part 4: 1970 or ASTM C 42-77. The core samples can also be used
for the following:
• Strength and density determination
• Depth of carbonation of concrete Chemical analysis
• Water/gas permeability
• Petrographic analysis
• ASHTO Chloride permeability test
• The strength of a test specimen depends on its shape, proportions, and size.
The influence of height/diameter (H/D) ratio on the recorded strength of
cylinder is an established fact.
• Strength of cores have to be related to the standard cylinder strengths i.e. for
H/D ratio of 2. Thus, core should preferably have this ratio near to 2. For values
of H/D between 1 and 2, a correction factor has to be applied.
• Cores with H/D less than 1 yield unreliable results and BS 1881: Pt 4: 1970
prescribes a minimum value as 0.95. The same Standard specifies the use of
150 mm or 100 mm cores. However, cores as small as 50 mm are also
permitted in other standards.
• Very small diameter cores exhibit more variability in results than larger dia
cores, hence their use is generally not recommended.
• The general rule adopted for fixing the core size, besides the H/D ratio, is the
nominal size of stone aggregate .The dia should be not less than 3 times the
maximum size of stone aggregate. For diameter of core less than 3 times the
size of stone aggregate, an increased number of cores have to be tested.
Instrument showing core cutting
Concrete Core
• Following are the factors, which affect the
compressive strength of extracted concrete cores:
• Size of Stone Aggregate: If the ratio of dia of core to maximum
size of stone aggregate is less than 3, a reduction in strength is
reported. For concrete with 20 mm size aggregate, 50 mm dia
core has been tested to give 10% lower results than with 100
mm dia cores.
• Presence of transverse reinforcing Steel: It is reported that the
presence of transverse steel causes a 5 to 15% reduction in
compressive strength of core. The effect of embedded steel is
higher on stronger concrete and as its location moves away from
ends i.e. towards the middle . However, presence of steel
parallel to the axis of the core is not desirable.
• H/D Ratio: This has already been discussed above. However, its
value should be minimum 0.95 and maximum as 2. Higher ratio
would cause a reduction in strength.
• Age of Concrete: No age allowance is recommended by the Concrete
Society as some evidence is reported to suggest that in-situ
concrete gains little strength after 28 days. Whereas others suggest
that under average conditions, the increase over 28 days’ strength is
10% after 3 months and 15% after 6 months. Hence it is not easy to
deal the effect of age on core strength.
• Strength of Concrete: The effect in reducing the core strength
appears to be higher in stronger concretes and reduction has been
reported as 15% for 40 MPa concrete. However, a reduction of 5 to
7 % is considered reasonable (concrete society Tech Report no. 11
“Council Core Testing for Strength”- The Concrete Society, 1987 )
• Drilling Operations: The strength of cores is generally less than that
of standard cylinders, partly as a consequence of disturbance due to
vibrations during drilling operations. Whatever best precautions are
taken during drilling, there is always a risk of slight damage.
• Site Conditions vis a vis Standard Specimens: Because site curing is
invariably inferior to curing prescribed for standard specimens, the
in-situ core strength is invariably lower than the standard specimen
taken and tested during concreting operations.
Chemical Tests :
• Chemical analysis of concrete can provide extremely useful information
regarding the cause of causes of failure of concrete . The tests most
frequently carried out are listed below :
1. Depth of carbonation
2. Chloride content
3. Cement content
4. Sulphate content
5. Type of cement
6. Alkali content
Carbonation Test :
• This test is carried out to determine the depth of concrete affected
due to combined attack of atmospheric carbon dioxide and moisture
causing a reduction in level of alkalinity of concrete . A spray of 0.2%
solution of phenolphthalein is used as pH indicator of concrete. The
change of colour of concrete to pink indicates that the concrete is in
the good health, where no change in colour takes place, it is
suggestive of carbonation-affected concrete . The test is conducted
by drilling a hole on the concrete surface to different depths upto
cover concrete thickness, removing dust by air blowing, spraying
phenolphthalein with physician’s injection syringe and needle on
such freshly drilled/ broken concrete and observing the colour
change. The depth of carbonation is estimated based on the change
in colour profile . The pH value can also be determined by analyzing
samples of mortar collected by drilling from the site, dissolving the
same in distilled water and thereby titration in laboratory.
Chloride Content
• Chloride content can be determined from broken samples or core samples
of concrete . Primarily, the level of chloride near the steel-concrete interface
is of prime importance. Chlorides present in concrete are fixed (water
insoluble) as well as free (water soluble). Though it is the water soluble
chloride ions, which are of importance from corrosion risk point of view, yet
total acid soluble (fixed as well as free) chloride contents are determined
and compared with the limiting values specified for the concrete to assess
the risk of corrosion in concrete.
• One recent development for field testing of chloride content includes the
use of chloride ion sensitive electrode . This is commercially known as
“Rapid chloride test kit-4”. The test consists of obtaining powdered samples
by drilling and collecting them from different depths (every 5 mm), mixing
the sample (of about 1.5 gm weight) with a special chloride extraction
liquid, and measuring the electrical potential of the liquid by chloride-ion
selective electrode . With the help of a calibration graph relating electrical
potential and chloride content, the chloride content of the samples can be
directly determined.
Corrosion Potential Assessment:
• Half-Cell Potential measurement method is used for finding out the status of
corrosion actively in the embedded steel.
• Cover meter survey
• A cover thickness survey is useful to determine existing cover thickness in a
specific location, where a damage has been identified and elsewhere, for
comparison on the same structure .
• The cover thickness can be measured non-destructively using commercially
known cover meters.
• The cover meters are also used to identify the location and diameter of
rebar .
• COVERMASTER and PROFOMETER are the commercially available
instruments, which are used to measure the cover thickness and rebar size.
• Table 3.12 shows how the cover meter readings are to be interpreted for
corrosion assessment.
• Half cell potential survey
• Corrosion being an electrochemical phenomenon, the electrode potential
of steel rebar with reference to a standard electrode undergoes changes
depending on corrosion activity.
• A systematic survey on well-defined grid points gives useful information on
the presence or probability of corrosion activity.
• The same grid points as used for other measurements, namely, rebound
hammer and UPV could be used for making the data more meaningful.
• The common standard electrodes used are:
1. Copper - Copper sulphate electrode (CSE)
2. Silver - Silver chloride electrode (SSE)
3. Standard Calomel electrode (SCE).
• The measurement consists of giving an electrical connection to the rebar
and observing the voltage difference between the bar and a reference
electrode in contact with concrete surface. [Fig 3.17(a)] Generally, the
voltage potential becomes more and more negative as the corrosion
becomes more and more active. However, less negative potential values
may also indicate the presence of corrosion activity, if the pH values of
concrete are less.
• Principle & Procedure :
• The instrument measures the potential and the electrical resistance
between the reinforcement and the surface to evaluate the corrosion
activity as well as the actual condition of the cover layer during testing.
The electrical activity of the steel reinforcement and the concrete leads
them to be considered as one half of weak battery cell with the steel
acting as one electrode and the concrete as the electrolyte. The name
half-cell surveying derives from the fact that the one half of the battery
cell is considered to be the steel reinforcing bar and the surrounding
concrete. The electrical potential of a point on the surface of steel
reinforcing bar can be measured comparing its potential with that of
copper – copper sulphate reference electrode on the surface.
Practically this achieved by connecting a wire from one terminal of a
voltmeter to the reinforcement and another wire to the copper
sulphate reference electrode. Then generally readings taken are at grid
of 1 x 1 m for slabs, walls and at 0.5 m c/c for Column, beams
Half-Cell Potential Test
Copper – Copper Sulphate Half-Cell
One end of Half-Cell
connected to the
reinforcement
Marking of Slab and Pre-
wetting for Half-Cell
Potential Test
Half-Cell Potential Test of Slab
Half-Cell Potential Test of Column
An Equi-potential contour map can be plotted to get an overall picture of the member
Half – Cell Equi-potential Contour Map
Significance and use :
1. This method may by used to indicate the corrosion activity associated with
steel embedded in concrete.
2. This method can be applied to members regardless of their size or the
depth of concrete cover.
3. This method can be used at the any time during the life of concrete
member.
Reliability & Limitations :
• The test does not detect actual corrosion rate or whether corrosion activity
has already started, but it indicates the probability of the corrosion activity
depending upon the actual surrounding conditions. If this method used in
combination with resistivity measurement , the accuracy is higher.
• If the concrete surface has dried to the extent that it is dielectric , then pre
wetting of concrete is essential especially for Cement Silos, Exposed roof
slab. The Quality of the cover concrete, particularly its moisture condition
and Contamination by carbonation and / or chlorides may affect the results.
• The effect of the concrete condition (dry or wet), presence of chloride,
absence of oxygen at the rebar surface (due to saturation), cover thickness,
concrete resistivity, and temperature are all factors that can influence the
results by shifting their potential reading towards a more positive or
negative value as shown in following table.
Conditions Potential values (mV/CSE*)
Humid, chloride free concrete -200 to +100
Wet, chloride contaminated
concrete
-600 to -400
Water saturated concrete without
oxygen
-1000 to -900
Humid, carbonated concrete -400 to +100
Dry, carbonated concrete 0 to +200
Dry concrete 0 to +200
Typical ranges of half-cell potentials of rebar in concrete (adapted from RILEM TC-154, 2003)
In addition, half-cell measurement is considered to be a zonal measurement as it will
take an average potential measurement of the surroundings. An example is illustrated
in Figure 3, where the measured potential will show sort of an average over a certain
distance and where the actual location of the corroded bar can be challenging to
distinguish, even with corrosion potential mapping.
Nevertheless, this technique is being widely used since it is the only corrosion
monitoring technique standardized by ASTM. It can be very useful in doing a quick
assessment and identifying the regions where there might be a relatively higher
corrosion activity. It remains that the corrosion potential technique's output is
qualitative as it provides information only on the chance of corrosion activity, not
quantitative information such as the rate at which the rebar is corroding; this is more
useful information when it comes to determining the plan of action for repair or
corrosion mitigation.
Resistivity Measurement
• Resistivity Mapping:
• The electrical resistance of concrete plays an important role in determining
the quality of concrete from the point of view ‘corrosion susceptibility
potential’ at any specific location. This parameter is expressed in terms of
“Resistivity” in ohm-cm.
• For general monitoring, a resistivity check is important because long-term
corrosion can be anticipated in concrete structures where accurately
measured values are below 10,000 ohm- cm.Further, if resistivity values fall
below 5,000 ohm-cm, corrosion must be anticipated at a much earlier
period (possibly within 5 years) in the life of a structure. Table 3.14 indicates
the general guidelines of resistivity values based on which areas having
probable corrosion risk can be identified in concrete structures.
• The method essentially consists of using a 4- probe technique in which a
known current is applied between two outer probes 100 mm apart and the
voltage drop between the inner two elements at 50 mm spacing, is read off
allowing for a direct evaluation of resistance R . Using a mathematical
conversion factor, resistivity is calculated as per principle of four probe
resistivity testing is illustrated in Fig 3.18.
Corrosion Probability based on Resistivity and Potential Mapping
CSE – Copper Sulphate Electrode
Fire Damage Assessment:
1. Differential Thermal Analysis (DTA)
• DTA is used to study the physical and chemical changes that
occur in a material when it is heated so as to characterise
the material. It is concerned with the rate of change of
temperature of a sample as it is heated at a constant rate of
heat flow.
• The principle on which DTA is based is that when a material
is slowly heated, its temperature rises but when the material
undergoes any endothermic reaction viz. losing water, losing
CO2, change in crystalline structure or decomposition, its
temperature remains constant.
2. X-ray Diffraction (Xrd):
• X-ray Diffraction (XRD) The atomic planes of a crystal cause an incident
beam of X-rays to interfere with one another as they leave the crystal. The
phenomenon is called X-ray diffraction.
• X-ray diffraction technique is based on the principle that a crystal of a
substance has a unique diffraction pattern.
• As regards to the assessment of fire damage, X-ray diffraction can be used
to determine the extent of deterioration in concrete that has been
subjected to fire. The temperature to which the damaged concrete has
been subjected to can be determined by this method.
• Reference :
• HANDBOOK ON REPAIR AND REHABILITATION OF RCC BUILDINGS
(CENTRAL PUBLIC WORKS DEPARTMENT )

More Related Content

What's hot

TEST ON HARDENED CONCRETE
TEST ON HARDENED CONCRETETEST ON HARDENED CONCRETE
TEST ON HARDENED CONCRETEJaswanth J
 
Destructive and Non- Destructive Testing for Concrete in Sudan - A Comparativ...
Destructive and Non- Destructive Testing for Concrete in Sudan - A Comparativ...Destructive and Non- Destructive Testing for Concrete in Sudan - A Comparativ...
Destructive and Non- Destructive Testing for Concrete in Sudan - A Comparativ...iosrjce
 
final year batch 4
final year batch 4final year batch 4
final year batch 4bbinitha
 
Rebound hammer & UPV- Non destructive test. Concrete NDT. Civil engineering....
Rebound hammer & UPV-  Non destructive test. Concrete NDT. Civil engineering....Rebound hammer & UPV-  Non destructive test. Concrete NDT. Civil engineering....
Rebound hammer & UPV- Non destructive test. Concrete NDT. Civil engineering....Yash Shah
 
Non Destructive Test
Non Destructive TestNon Destructive Test
Non Destructive TestParth Desani
 
NDT (NON DESTRUCTIVE TESTING) OF CONCRETE STRUCTURE ANSHUL
NDT (NON DESTRUCTIVE TESTING) OF CONCRETE STRUCTURE ANSHULNDT (NON DESTRUCTIVE TESTING) OF CONCRETE STRUCTURE ANSHUL
NDT (NON DESTRUCTIVE TESTING) OF CONCRETE STRUCTURE ANSHULAnshul Shakya
 
Non-destructive testing
Non-destructive testingNon-destructive testing
Non-destructive testingparth mehta
 
Case study on non destructive testing on concrete structures
Case study on non destructive testing on concrete structuresCase study on non destructive testing on concrete structures
Case study on non destructive testing on concrete structuresLahmeyer International, UAE
 
Non destructive test (ndt) on concrete msu
Non destructive test (ndt) on concrete msuNon destructive test (ndt) on concrete msu
Non destructive test (ndt) on concrete msuSagar Vekariya
 
Rebound Hammer Test-priciple,procedure,cons&pros.....
Rebound Hammer Test-priciple,procedure,cons&pros.....Rebound Hammer Test-priciple,procedure,cons&pros.....
Rebound Hammer Test-priciple,procedure,cons&pros.....SJMIT,now NMAMIT NITTE
 
Corrosion Assessment – Half-Cell Potential Method for reinforced concrete
Corrosion Assessment – Half-Cell Potential Method for reinforced concreteCorrosion Assessment – Half-Cell Potential Method for reinforced concrete
Corrosion Assessment – Half-Cell Potential Method for reinforced concreteYash Shah
 
Non Destructive and Partially Destructive Testing Of Concrete Structures
Non Destructive and Partially Destructive Testing Of Concrete StructuresNon Destructive and Partially Destructive Testing Of Concrete Structures
Non Destructive and Partially Destructive Testing Of Concrete StructuresGautam Chaurasia
 
Rebound hammer test
Rebound hammer testRebound hammer test
Rebound hammer testPramod GK
 
ndt testing of concrete
ndt testing of concretendt testing of concrete
ndt testing of concreteMohd Sazid
 
Non destructive testing on concrete ( ndt )
Non destructive testing on concrete  ( ndt )Non destructive testing on concrete  ( ndt )
Non destructive testing on concrete ( ndt )RakeshRaki94
 
Non destructive testing of railway bridges
Non destructive testing of railway bridgesNon destructive testing of railway bridges
Non destructive testing of railway bridgesHarsh Singh
 
summer training report .... non destructive testing equipments for railway br...
summer training report .... non destructive testing equipments for railway br...summer training report .... non destructive testing equipments for railway br...
summer training report .... non destructive testing equipments for railway br...Neha Singh
 

What's hot (20)

TEST ON HARDENED CONCRETE
TEST ON HARDENED CONCRETETEST ON HARDENED CONCRETE
TEST ON HARDENED CONCRETE
 
Destructive and Non- Destructive Testing for Concrete in Sudan - A Comparativ...
Destructive and Non- Destructive Testing for Concrete in Sudan - A Comparativ...Destructive and Non- Destructive Testing for Concrete in Sudan - A Comparativ...
Destructive and Non- Destructive Testing for Concrete in Sudan - A Comparativ...
 
final year batch 4
final year batch 4final year batch 4
final year batch 4
 
Rebound hammer & UPV- Non destructive test. Concrete NDT. Civil engineering....
Rebound hammer & UPV-  Non destructive test. Concrete NDT. Civil engineering....Rebound hammer & UPV-  Non destructive test. Concrete NDT. Civil engineering....
Rebound hammer & UPV- Non destructive test. Concrete NDT. Civil engineering....
 
Non Destructive Test
Non Destructive TestNon Destructive Test
Non Destructive Test
 
NDT (NON DESTRUCTIVE TESTING) OF CONCRETE STRUCTURE ANSHUL
NDT (NON DESTRUCTIVE TESTING) OF CONCRETE STRUCTURE ANSHULNDT (NON DESTRUCTIVE TESTING) OF CONCRETE STRUCTURE ANSHUL
NDT (NON DESTRUCTIVE TESTING) OF CONCRETE STRUCTURE ANSHUL
 
Ndt
NdtNdt
Ndt
 
Non Destructive test
Non Destructive testNon Destructive test
Non Destructive test
 
Non-destructive testing
Non-destructive testingNon-destructive testing
Non-destructive testing
 
Case study on non destructive testing on concrete structures
Case study on non destructive testing on concrete structuresCase study on non destructive testing on concrete structures
Case study on non destructive testing on concrete structures
 
Non destructive test (ndt) on concrete msu
Non destructive test (ndt) on concrete msuNon destructive test (ndt) on concrete msu
Non destructive test (ndt) on concrete msu
 
Rebound Hammer Test-priciple,procedure,cons&pros.....
Rebound Hammer Test-priciple,procedure,cons&pros.....Rebound Hammer Test-priciple,procedure,cons&pros.....
Rebound Hammer Test-priciple,procedure,cons&pros.....
 
Corrosion Assessment – Half-Cell Potential Method for reinforced concrete
Corrosion Assessment – Half-Cell Potential Method for reinforced concreteCorrosion Assessment – Half-Cell Potential Method for reinforced concrete
Corrosion Assessment – Half-Cell Potential Method for reinforced concrete
 
Non Destructive and Partially Destructive Testing Of Concrete Structures
Non Destructive and Partially Destructive Testing Of Concrete StructuresNon Destructive and Partially Destructive Testing Of Concrete Structures
Non Destructive and Partially Destructive Testing Of Concrete Structures
 
Timmareddy
TimmareddyTimmareddy
Timmareddy
 
Rebound hammer test
Rebound hammer testRebound hammer test
Rebound hammer test
 
ndt testing of concrete
ndt testing of concretendt testing of concrete
ndt testing of concrete
 
Non destructive testing on concrete ( ndt )
Non destructive testing on concrete  ( ndt )Non destructive testing on concrete  ( ndt )
Non destructive testing on concrete ( ndt )
 
Non destructive testing of railway bridges
Non destructive testing of railway bridgesNon destructive testing of railway bridges
Non destructive testing of railway bridges
 
summer training report .... non destructive testing equipments for railway br...
summer training report .... non destructive testing equipments for railway br...summer training report .... non destructive testing equipments for railway br...
summer training report .... non destructive testing equipments for railway br...
 

Similar to Non-Destructive Evaluation Tests Guide

Non destructive test in CIVIL ENGINEERING Construction
Non destructive test in CIVIL ENGINEERING Construction Non destructive test in CIVIL ENGINEERING Construction
Non destructive test in CIVIL ENGINEERING Construction SAURABH GUPTA
 
Testing of hardened concrete
Testing of hardened concreteTesting of hardened concrete
Testing of hardened concreteJ C
 
nondestructivetestonconcrete-190605050413 (1).pdf
nondestructivetestonconcrete-190605050413 (1).pdfnondestructivetestonconcrete-190605050413 (1).pdf
nondestructivetestonconcrete-190605050413 (1).pdfHarshaS71
 
Non destruction test
Non destruction testNon destruction test
Non destruction testJaswanth J
 
Strength evaluation of existing structures
Strength evaluation of existing structuresStrength evaluation of existing structures
Strength evaluation of existing structuresShahrukh Niaz
 
UNIT 5 PART 2.pptx
UNIT 5 PART 2.pptxUNIT 5 PART 2.pptx
UNIT 5 PART 2.pptxSHRUTHIBS16
 
Non destructive testing of structures
Non destructive testing of structuresNon destructive testing of structures
Non destructive testing of structuressanjanam9
 
Non-Destructive-Testing-of-Concrete • Repair / Rehabilitation / Restoration
Non-Destructive-Testing-of-Concrete • Repair / Rehabilitation / RestorationNon-Destructive-Testing-of-Concrete • Repair / Rehabilitation / Restoration
Non-Destructive-Testing-of-Concrete • Repair / Rehabilitation / Restorationpandian18
 
Non destructive test on concrete (ndt)
Non destructive test on concrete (ndt)Non destructive test on concrete (ndt)
Non destructive test on concrete (ndt)Abhishek Gupta
 
1.2_Basic Engineering_Day 4.pptx
1.2_Basic Engineering_Day 4.pptx1.2_Basic Engineering_Day 4.pptx
1.2_Basic Engineering_Day 4.pptxJanak82
 
Non destructive testing
Non destructive testingNon destructive testing
Non destructive testingM A Azeem
 
Condition Survey, Evaluation & Damage Assessment
Condition Survey, Evaluation & Damage AssessmentCondition Survey, Evaluation & Damage Assessment
Condition Survey, Evaluation & Damage Assessmentwasim shaikh
 
Non destructive tests on Concrete.pptx
Non destructive tests on Concrete.pptxNon destructive tests on Concrete.pptx
Non destructive tests on Concrete.pptxReigerRoyal
 
Non destructive testing (Civil Engineering )
Non destructive testing (Civil Engineering )Non destructive testing (Civil Engineering )
Non destructive testing (Civil Engineering )AkashBhardwaj103
 
Condition survey and non destructive evalution of concrete
Condition survey and non destructive evalution of concreteCondition survey and non destructive evalution of concrete
Condition survey and non destructive evalution of concreteAvinash Kumar Gupta
 
Non destructive test
Non destructive test   Non destructive test
Non destructive test NIRAV SHAH
 

Similar to Non-Destructive Evaluation Tests Guide (20)

Techshore Inspection Services-Concrete NDT.pdf
Techshore Inspection Services-Concrete NDT.pdfTechshore Inspection Services-Concrete NDT.pdf
Techshore Inspection Services-Concrete NDT.pdf
 
Non destructive test in CIVIL ENGINEERING Construction
Non destructive test in CIVIL ENGINEERING Construction Non destructive test in CIVIL ENGINEERING Construction
Non destructive test in CIVIL ENGINEERING Construction
 
Testing of hardened concrete
Testing of hardened concreteTesting of hardened concrete
Testing of hardened concrete
 
nondestructivetestonconcrete-190605050413 (1).pdf
nondestructivetestonconcrete-190605050413 (1).pdfnondestructivetestonconcrete-190605050413 (1).pdf
nondestructivetestonconcrete-190605050413 (1).pdf
 
Concrete Technology
Concrete TechnologyConcrete Technology
Concrete Technology
 
Non destruction test
Non destruction testNon destruction test
Non destruction test
 
Strength evaluation of existing structures
Strength evaluation of existing structuresStrength evaluation of existing structures
Strength evaluation of existing structures
 
UNIT 5 PART 2.pptx
UNIT 5 PART 2.pptxUNIT 5 PART 2.pptx
UNIT 5 PART 2.pptx
 
Cement and concrete destructive tests,
Cement and concrete destructive tests,Cement and concrete destructive tests,
Cement and concrete destructive tests,
 
Non destructive testing of structures
Non destructive testing of structuresNon destructive testing of structures
Non destructive testing of structures
 
Non-Destructive-Testing-of-Concrete • Repair / Rehabilitation / Restoration
Non-Destructive-Testing-of-Concrete • Repair / Rehabilitation / RestorationNon-Destructive-Testing-of-Concrete • Repair / Rehabilitation / Restoration
Non-Destructive-Testing-of-Concrete • Repair / Rehabilitation / Restoration
 
UNIT 4.ppt
UNIT 4.pptUNIT 4.ppt
UNIT 4.ppt
 
Non destructive test on concrete (ndt)
Non destructive test on concrete (ndt)Non destructive test on concrete (ndt)
Non destructive test on concrete (ndt)
 
1.2_Basic Engineering_Day 4.pptx
1.2_Basic Engineering_Day 4.pptx1.2_Basic Engineering_Day 4.pptx
1.2_Basic Engineering_Day 4.pptx
 
Non destructive testing
Non destructive testingNon destructive testing
Non destructive testing
 
Condition Survey, Evaluation & Damage Assessment
Condition Survey, Evaluation & Damage AssessmentCondition Survey, Evaluation & Damage Assessment
Condition Survey, Evaluation & Damage Assessment
 
Non destructive tests on Concrete.pptx
Non destructive tests on Concrete.pptxNon destructive tests on Concrete.pptx
Non destructive tests on Concrete.pptx
 
Non destructive testing (Civil Engineering )
Non destructive testing (Civil Engineering )Non destructive testing (Civil Engineering )
Non destructive testing (Civil Engineering )
 
Condition survey and non destructive evalution of concrete
Condition survey and non destructive evalution of concreteCondition survey and non destructive evalution of concrete
Condition survey and non destructive evalution of concrete
 
Non destructive test
Non destructive test   Non destructive test
Non destructive test
 

Recently uploaded

Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerAnamika Sarkar
 
Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024hassan khalil
 
HARMONY IN THE HUMAN BEING - Unit-II UHV-2
HARMONY IN THE HUMAN BEING - Unit-II UHV-2HARMONY IN THE HUMAN BEING - Unit-II UHV-2
HARMONY IN THE HUMAN BEING - Unit-II UHV-2RajaP95
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxJoão Esperancinha
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxpurnimasatapathy1234
 
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort serviceGurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort servicejennyeacort
 
chaitra-1.pptx fake news detection using machine learning
chaitra-1.pptx  fake news detection using machine learningchaitra-1.pptx  fake news detection using machine learning
chaitra-1.pptx fake news detection using machine learningmisbanausheenparvam
 
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfCCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfAsst.prof M.Gokilavani
 
Artificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptxArtificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptxbritheesh05
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.eptoze12
 
Application of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptxApplication of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptx959SahilShah
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSKurinjimalarL3
 
microprocessor 8085 and its interfacing
microprocessor 8085  and its interfacingmicroprocessor 8085  and its interfacing
microprocessor 8085 and its interfacingjaychoudhary37
 
Heart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxHeart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxPoojaBan
 
Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...VICTOR MAESTRE RAMIREZ
 
SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )Tsuyoshi Horigome
 
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective IntroductionSachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective IntroductionDr.Costas Sachpazis
 
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝soniya singh
 

Recently uploaded (20)

Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
 
Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024
 
HARMONY IN THE HUMAN BEING - Unit-II UHV-2
HARMONY IN THE HUMAN BEING - Unit-II UHV-2HARMONY IN THE HUMAN BEING - Unit-II UHV-2
HARMONY IN THE HUMAN BEING - Unit-II UHV-2
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptx
 
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort serviceGurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
 
chaitra-1.pptx fake news detection using machine learning
chaitra-1.pptx  fake news detection using machine learningchaitra-1.pptx  fake news detection using machine learning
chaitra-1.pptx fake news detection using machine learning
 
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdfCCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
 
Artificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptxArtificial-Intelligence-in-Electronics (K).pptx
Artificial-Intelligence-in-Electronics (K).pptx
 
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
 
Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.
 
Application of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptxApplication of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptx
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
 
microprocessor 8085 and its interfacing
microprocessor 8085  and its interfacingmicroprocessor 8085  and its interfacing
microprocessor 8085 and its interfacing
 
Heart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxHeart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptx
 
Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...
 
SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )
 
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective IntroductionSachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
 
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
 

Non-Destructive Evaluation Tests Guide

  • 2. NON DESTRUCTIVE EVALUATION TESTS : • The term ‘non destructive’ is used to indicate that it does not impair the intended performance of the structural member being tested/investigated. • The non- destructive evaluation have been broadly classified under two broad categories viz ‘in-situ field test’ and ‘laboratory test’. These tests have been put under five categories depending on the purpose of test as under : 1. In-situ Concrete Strength 2. Chemical Attack 3. Corrosion Activity 4. Fire Damage 5. Structural Integrity/Soundness
  • 3. Sl No TestMethod Details A. Insitu Concrete Strength: 1 Rebound Hammer Test A qualitative field test method to measure surface hardnessof concrete 2 Ultrasonic Pulse Velocity Aqualitativefield testbymeasurement ofUltrasonicPulse Velocity (UPV) 3 Windsor Probe A qualitative field test for assessment of near surface strength of concrete 4 Capo/Pull out test -do- 5 a. Core cutting/ sampling b. Lab Testing of Cores Fieldcum lab test method for assessing qualityof concrete as under: - strength - density - texture 6. Load Test - permeability A field test for assessing the load carrying capacity within the limits of elastic deformations B. Chemical Attack 1 Carbonation Test A field/lab test for assessment of pH ofconcrete and depth of carbonation 2 Chloride Test A field/lab Test for assessment of total water/acid soluble chloride contents 3 Sulphate Test A Lab Test for assessment of total acid/water soluble sulphate contents of concrete
  • 4. C. Corrosion Potential Assessment 1 Cover-Meter / Profo-meter A field method for measuring measurement -thickness of cover concrete (In-situ Test) -reinforcement diameter -reinforcement spacing. 2 Half Cell Method A field method for Measuring/ plotting corrosion potential for assessing probability of corrosion 3 Resistivity Meter A field method for assessing electrical resistivity of concrete to determine its corrosion resistance 4 Permeability a. Water b. Air A field/Lab method for assessment of in-situ permeability of concrete due to water and air.
  • 5. D. Fire Damage Assessment Thermo-Gravimetric A laboratory test for assessment of temperature Analysis (TGA) range to which concrete was subjected to Differential Thermal A laboratory Test for assessment of qualitative Analysis (DTA) & quantitative composition of sample of concrete X-ray Diffraction (XRD) To determine the extent of deterioration in concrete subjected to fire E. Structural Integrity/Soundness Assessment 1. Ultra-sonic Pulse velocity A field method for determination of discontinuities, cracks and depth of cracks 2 Radiography For taking photographs showing details of inside of a concrete member, where other NDEmethods arenotsuitable 3 Impact Echo Test A field/laboratory test method to detect hidden damage And its extent.
  • 6. Rebound Hammer Test : • Hammer is also called Schmidt’s Hammer test. • When the plunger of rebound hammer is pressed against the surface of concrete, a spring controlled mass with a constant energy is made to hit concrete surface to rebound back. • The extent of rebound, which is a measure of surface hardness, is measured on a graduated scale. • This measured value is designated as Rebound Number (a rebound index). A concrete with low strength and low stiffness will absorb more energy to yield in a lower rebound value.
  • 7.
  • 8. • IS 13311 Pt-2-1992 as well as BS: 6089-81 and BS: 1881:Pt-202 explains the standard procedure for test and correlation between concrete cube crushing strength and rebound number. The results are significantly affected by the following factors : A. Mix characteristics : 1. Cement type, 2. Cement Content, 3. Coarse aggregate type B. Angle of Inclination of direction of hammer with reference to horizontal. A. Member Characteristics, 1. Mass, 2. Compaction, 3. Surface type, 4. Age, rate of hardening and curing type, 5. Surface carbonation, 6. Moisture Condition, 7. Stress state and temperature.
  • 9.
  • 10. Strength Assessment • This test is conducted to assess the relative strength of concrete based on the hardness at or near its exposed surface. Carrying of periodic calibration of rebound hammer using standard anvil is desirable. • However for new concrete construction, rebound hammer is calibrated on concrete test cubes for a given source of constituent materials (viz. cement, sand and stone aggregate), this calibration data can be used with reasonable accuracy in arriving at equivalent in-situ cube strength of relatively new concrete ( i.e. not more than three months old concrete). • This calibration exercise may be carried out in a concrete lab by casting cubes of designed mix and testing these under controlled condition with rebound hammer as well as test to destruction in compression.
  • 11. Strength Assessment • Calibration graphs then can be drawn. Large number of readings are desirable to reduce the effects of variability in readings due to various localized as well as instrument factors. This method may give highly erroneous results for concrete whose surface is exposed to atmosphere for longer periods say more than three months. This is due to hardening of concrete surface due to carbonation, which may cause overestimation as much as 50% for old structure. • Hence Strength assessment by Rebound Hammer Test should generally be restricted to relatively new structures only.
  • 12. Survey of Weak & delaminating Concrete • As the test requires a flat surface and large number of readings to reduce variability, this test is not generally suitable for use on spalled concrete surfaces of distressed structures. • However, comparison of Rebound numbers, which indicate the near surface hardness of the concrete, will help to identify relative surface weaknesses in cover concrete and also can be used to determine the relative compressive strength of concrete. • Locations possessing very low rebound numbers will be identified as weak surface concrete and such locations will be identified for further investigations like corrosion distress, fire damage and/or any other reason including original construction defects of concrete.
  • 13. • Locations possessing very low rebound numbers will be identified as weak surface concrete and such locations will be identified for further investigations like corrosion distress, fire damage and/or any other reason including original construction defects of concrete. This survey is to be carried out on each identified member in a systematic way by dividing the member into well- defined grid points. • The grid matrix should have a spacing of approximately 300mmx 300mm. Table 3.8 gives guidelines for qualitative interpretation of rebound hammer test results with reference to quality.
  • 14. Ultrasonic Pulse Velocity (UPV) test • Ultrasonic scanning is a recognized non-destructive evaluation test to qualitatively assess the homogeneity and integrity of concrete. With this technique, following can be assessed. 1. Qualitative assessment of strength of concrete, its gradation in different locations of structural members and plotting the same 2. Any discontinuity in cross section like cracks, cover concrete delamination etc 3. Depth of surface cracks.
  • 15. UPV • This test essentially consists of measuring travel time, ‘T’ of ultrasonic pulse of 50-54 kHz, produced by an electro-acoustical transducer, held in contact with one surface of the concrete member under test and receiving the same by a similar transducer in contact with the surface at the other end. • With the path length, ‘L’ (i.e. the distance between the two probes) and time of travel, T the pulse velocity (V = L/T) is calculated (fig 3.8). • Higher the elastic modulus, density and integrity of the concrete, higher is the pulse velocity . The ultrasonic pulse velocity depends on the density and elastic properties of the material being tested. • Though, pulse velocity is related with crushing strength of concrete, yet no statistical correlation can be applied.
  • 16.
  • 17. • The pulse velocity in concrete may be influenced by 1. Path length 2. Lateral dimensions of the specimen tested. 3. Presence of reinforcing steel 4. Moisture content of the concrete. • The influence of path length will be negligible provided it is not less than 100 mm when 20 mm size aggregate is used or less than 150 mm for 40 mm size aggregate. Pulse velocity will not be influenced by the shape of the specimen, provided its least lateral dimension (i.e. its dimension measured at right angles to the pulse path ) is not less than the wavelength of the pulse vibrations . • For pulse of 50 Hz frequency, this corresponds to a least lateral dimension of about 80 mm. The velocity of pulses in a steel bar is generally higher than they are in concrete .
  • 18. • For this reason, pulse velocity measurements made in the vicinity of reinforcing steel may be high and not representative of the concrete . • The influence of the reinforcement is generally small if the bars run in a direction at right angles to the pulse path and the quantity of steel is small in relation to the path length . • The moisture content of concrete can have a small but significant influence on the pulse velocity. • In general, the velocity is increased with increased moisture content, the influence being more marked for lower quality concrete.
  • 19. • Measurement of pulse velocities at points on a regular grid on the surface of a concrete structure provides a reliable method of assessing the homogeneity of the concrete . The size of the grid chosen will depend on the size of the structure and the amount of variability encountered.
  • 20.
  • 21. Detection of defects • When an ultrasonic pulse traveling through concrete meets a concrete-air- interface, there is a negligible transmission of energy across this interface so that any air-filled crack or void lying directly between the transducers will obstruct the direct beam of ultrasound when the void has a projected area larger than the area of transducer faces. • The first pulse to arrive at the receiving transducer will have been diffracted around the periphery of the defect and the time will be longer than in similar concrete with no defect.
  • 22. Estimating the depth of cracks. • An estimate of the depth of a crack visible at the surface can be obtained by measuring the transit times across the crack for two different arrangements of the transducers placed on the surface. • One suitable arrangement is one in which the transmitting and receiving transducers are placed on opposite sides of the crack and distant from it. Two values of ‘x’ are chosen, one being twice that of the other, and the transmit times corresponding to these are measured . • An equation may be derived by assuming that the plane of the crack is perpendicular to the concrete surface and that the concrete in the vicinity of the crack is of reasonably uniform quality . It is important that the distance ‘x’ be measured accurately and that very good coupling is developed between the transducers and the concrete surface. The method is valid provided the crack is not filled with water.
  • 23. Penetration Resistance (‘Windsor Probe’) • This technique offers a means of determining relative strengths of concrete in the same structure or relative strength of different structures. Because of the nature of equipment, it can not, and should not be expected to yield absolute values of strength. ASTM C-803 gives this standard test method titled, “ penetration resistance of hardened concrete”. • Windsor Probe’, as commercially known, is penetration resistance measurement equipment, which consists of a gun powder actuated driver, hardened alloy rod probe, loaded cartridges, a depth gauge and other related accessories.
  • 24. • In this technique, a gunpowder-actuated driver is used to fire a hardened alloy probe into the concrete. • During testing, it is the exposed length of probe, which is measured by a calibration depth gauge. • But, it is preferable to express the coefficient of variation in terms of the depth of penetration as the fundamental relation is between concrete strength and penetration depth. • The probe shown in fig. No. 3.9 has a diameter of 6.3 mm, length of 73 mm, and conical point at the tip . The rear of the probe is threaded and screwed into a probe-driving head, which is 12.6 mm in diameter and fits snugly along with a rubber washer into the bore of the driver. • As the probe penetrates into the concrete, test results are usually not affected by local surface conditions, such as texture and moisture content. However, damage in the form of cracking may be caused to slender members. A minimum edge distance and member thickness of 150 mm is required. It is important to leave 50mm distance from the reinforcements present in the member since the presence of the reinforcing bars within the zone of influence of the penetrating probe affects the penetration depth.
  • 26. Pullout (LOK) Test • The fundamental principle behind pull out testing with LOK-test and CAPO test is that test equipment designed to a specific geometry will produce results (pull-out forces ) that closely correlate to the compressive strength of concrete. • This correlation is achieved by measuring the force required to pull a steel disc or ring, embedded in fresh concrete, against a circular counter pressure placed on the concrete surface concentric with the disc/ring. • For hardened concrete, an expandable steel ring is used instead. This ring expands to fit a specially drilled hole and routed recess in the concrete. The first method, shown in figure 3.13 using the cast in steel disc, is called LOK test.
  • 28. • The second method , shown in figure 3.14 using expandable ring, is called CAPO- test (i.e. Cut And Pull Out Test) The diameter of both the disc and ring is 25mm. The distance to the concrete surface is also 25mm. The inner diameter of the counter pressure is 55mm.
  • 29. Fig.-3.14 CAPO test testing principle
  • 30.
  • 31. • The major limitation with this test is that it requires special care at the time of placement of inserts to minimise air voids below disc besides a pre-planned usage. • Pull out tests are used to: i. Determine in-situ compressive strength of the concrete. ii. Ascertain the strength of concrete for carrying out post- tensioning operations. iii. Determine the time for removal of forms and shores based on actual in-situ strength of the structure. iv. Terminate curing based on in-situ strength of the structure. • Here item no (i) only are of relevance for residual strength assessment of old & distressed structures. It can be also used for testing repaired concrete sections. These tests are divided under the following two categories: 1. Embedding an insert into the fresh concrete while casting and then pulling out with a jack (LOK test- LOK meaning “punch”) after hardening after a specified period. 2. Insert fixed into a hole drilled into the hardened concrete and then pulling out with a jack (CAPO test- cut and pull out).This second method offers greater flexibility for conducting in-situ tests on hardened concrete of existing structures and is explained above in detail. • After the concrete has fractured by this test, the holes left in the surface are first cleaned of the dust by a blower . It is then primed with epoxy glue and the hole is filled with a polymer- modified mortar immediately thereafter and the surface is smoothened.
  • 32. • Core Sampling and Testing • While rebound hammer, Capo/Pullout, Windsor probe and ultrasonic pulse velocity tests give indirect evidence of concrete quality, a more direct assessment on strength can be made by core sampling and testing. Cores are usually cut by means of a rotary cutting tool with diamond bits. In this manner, a cylindrical specimen is obtained, usually with its ends being uneven, parallel and square and sometimes with embedded pieces of reinforcement. The cores are visually described and photographed, giving specific attention to compaction, distribution of aggregate, presence of steel etc. The core should then be soaked in water, capped with molten sulpher to make its ends plane, parallel, at right angle and then tested in compression in a moist condition as per BS 1881: Part 4: 1970 or ASTM C 42-77. The core samples can also be used for the following: • Strength and density determination • Depth of carbonation of concrete Chemical analysis • Water/gas permeability • Petrographic analysis • ASHTO Chloride permeability test
  • 33. • The strength of a test specimen depends on its shape, proportions, and size. The influence of height/diameter (H/D) ratio on the recorded strength of cylinder is an established fact. • Strength of cores have to be related to the standard cylinder strengths i.e. for H/D ratio of 2. Thus, core should preferably have this ratio near to 2. For values of H/D between 1 and 2, a correction factor has to be applied. • Cores with H/D less than 1 yield unreliable results and BS 1881: Pt 4: 1970 prescribes a minimum value as 0.95. The same Standard specifies the use of 150 mm or 100 mm cores. However, cores as small as 50 mm are also permitted in other standards. • Very small diameter cores exhibit more variability in results than larger dia cores, hence their use is generally not recommended. • The general rule adopted for fixing the core size, besides the H/D ratio, is the nominal size of stone aggregate .The dia should be not less than 3 times the maximum size of stone aggregate. For diameter of core less than 3 times the size of stone aggregate, an increased number of cores have to be tested.
  • 36. • Following are the factors, which affect the compressive strength of extracted concrete cores: • Size of Stone Aggregate: If the ratio of dia of core to maximum size of stone aggregate is less than 3, a reduction in strength is reported. For concrete with 20 mm size aggregate, 50 mm dia core has been tested to give 10% lower results than with 100 mm dia cores. • Presence of transverse reinforcing Steel: It is reported that the presence of transverse steel causes a 5 to 15% reduction in compressive strength of core. The effect of embedded steel is higher on stronger concrete and as its location moves away from ends i.e. towards the middle . However, presence of steel parallel to the axis of the core is not desirable. • H/D Ratio: This has already been discussed above. However, its value should be minimum 0.95 and maximum as 2. Higher ratio would cause a reduction in strength.
  • 37. • Age of Concrete: No age allowance is recommended by the Concrete Society as some evidence is reported to suggest that in-situ concrete gains little strength after 28 days. Whereas others suggest that under average conditions, the increase over 28 days’ strength is 10% after 3 months and 15% after 6 months. Hence it is not easy to deal the effect of age on core strength. • Strength of Concrete: The effect in reducing the core strength appears to be higher in stronger concretes and reduction has been reported as 15% for 40 MPa concrete. However, a reduction of 5 to 7 % is considered reasonable (concrete society Tech Report no. 11 “Council Core Testing for Strength”- The Concrete Society, 1987 ) • Drilling Operations: The strength of cores is generally less than that of standard cylinders, partly as a consequence of disturbance due to vibrations during drilling operations. Whatever best precautions are taken during drilling, there is always a risk of slight damage. • Site Conditions vis a vis Standard Specimens: Because site curing is invariably inferior to curing prescribed for standard specimens, the in-situ core strength is invariably lower than the standard specimen taken and tested during concreting operations.
  • 38. Chemical Tests : • Chemical analysis of concrete can provide extremely useful information regarding the cause of causes of failure of concrete . The tests most frequently carried out are listed below : 1. Depth of carbonation 2. Chloride content 3. Cement content 4. Sulphate content 5. Type of cement 6. Alkali content
  • 39. Carbonation Test : • This test is carried out to determine the depth of concrete affected due to combined attack of atmospheric carbon dioxide and moisture causing a reduction in level of alkalinity of concrete . A spray of 0.2% solution of phenolphthalein is used as pH indicator of concrete. The change of colour of concrete to pink indicates that the concrete is in the good health, where no change in colour takes place, it is suggestive of carbonation-affected concrete . The test is conducted by drilling a hole on the concrete surface to different depths upto cover concrete thickness, removing dust by air blowing, spraying phenolphthalein with physician’s injection syringe and needle on such freshly drilled/ broken concrete and observing the colour change. The depth of carbonation is estimated based on the change in colour profile . The pH value can also be determined by analyzing samples of mortar collected by drilling from the site, dissolving the same in distilled water and thereby titration in laboratory.
  • 40. Chloride Content • Chloride content can be determined from broken samples or core samples of concrete . Primarily, the level of chloride near the steel-concrete interface is of prime importance. Chlorides present in concrete are fixed (water insoluble) as well as free (water soluble). Though it is the water soluble chloride ions, which are of importance from corrosion risk point of view, yet total acid soluble (fixed as well as free) chloride contents are determined and compared with the limiting values specified for the concrete to assess the risk of corrosion in concrete. • One recent development for field testing of chloride content includes the use of chloride ion sensitive electrode . This is commercially known as “Rapid chloride test kit-4”. The test consists of obtaining powdered samples by drilling and collecting them from different depths (every 5 mm), mixing the sample (of about 1.5 gm weight) with a special chloride extraction liquid, and measuring the electrical potential of the liquid by chloride-ion selective electrode . With the help of a calibration graph relating electrical potential and chloride content, the chloride content of the samples can be directly determined.
  • 41.
  • 43. • Half-Cell Potential measurement method is used for finding out the status of corrosion actively in the embedded steel. • Cover meter survey • A cover thickness survey is useful to determine existing cover thickness in a specific location, where a damage has been identified and elsewhere, for comparison on the same structure . • The cover thickness can be measured non-destructively using commercially known cover meters. • The cover meters are also used to identify the location and diameter of rebar . • COVERMASTER and PROFOMETER are the commercially available instruments, which are used to measure the cover thickness and rebar size. • Table 3.12 shows how the cover meter readings are to be interpreted for corrosion assessment.
  • 44.
  • 45. • Half cell potential survey • Corrosion being an electrochemical phenomenon, the electrode potential of steel rebar with reference to a standard electrode undergoes changes depending on corrosion activity. • A systematic survey on well-defined grid points gives useful information on the presence or probability of corrosion activity. • The same grid points as used for other measurements, namely, rebound hammer and UPV could be used for making the data more meaningful. • The common standard electrodes used are: 1. Copper - Copper sulphate electrode (CSE) 2. Silver - Silver chloride electrode (SSE) 3. Standard Calomel electrode (SCE). • The measurement consists of giving an electrical connection to the rebar and observing the voltage difference between the bar and a reference electrode in contact with concrete surface. [Fig 3.17(a)] Generally, the voltage potential becomes more and more negative as the corrosion becomes more and more active. However, less negative potential values may also indicate the presence of corrosion activity, if the pH values of concrete are less.
  • 46.
  • 47. • Principle & Procedure : • The instrument measures the potential and the electrical resistance between the reinforcement and the surface to evaluate the corrosion activity as well as the actual condition of the cover layer during testing. The electrical activity of the steel reinforcement and the concrete leads them to be considered as one half of weak battery cell with the steel acting as one electrode and the concrete as the electrolyte. The name half-cell surveying derives from the fact that the one half of the battery cell is considered to be the steel reinforcing bar and the surrounding concrete. The electrical potential of a point on the surface of steel reinforcing bar can be measured comparing its potential with that of copper – copper sulphate reference electrode on the surface. Practically this achieved by connecting a wire from one terminal of a voltmeter to the reinforcement and another wire to the copper sulphate reference electrode. Then generally readings taken are at grid of 1 x 1 m for slabs, walls and at 0.5 m c/c for Column, beams
  • 48.
  • 49.
  • 50. Half-Cell Potential Test Copper – Copper Sulphate Half-Cell One end of Half-Cell connected to the reinforcement Marking of Slab and Pre- wetting for Half-Cell Potential Test
  • 51. Half-Cell Potential Test of Slab Half-Cell Potential Test of Column
  • 52. An Equi-potential contour map can be plotted to get an overall picture of the member Half – Cell Equi-potential Contour Map
  • 53.
  • 54. Significance and use : 1. This method may by used to indicate the corrosion activity associated with steel embedded in concrete. 2. This method can be applied to members regardless of their size or the depth of concrete cover. 3. This method can be used at the any time during the life of concrete member. Reliability & Limitations : • The test does not detect actual corrosion rate or whether corrosion activity has already started, but it indicates the probability of the corrosion activity depending upon the actual surrounding conditions. If this method used in combination with resistivity measurement , the accuracy is higher. • If the concrete surface has dried to the extent that it is dielectric , then pre wetting of concrete is essential especially for Cement Silos, Exposed roof slab. The Quality of the cover concrete, particularly its moisture condition and Contamination by carbonation and / or chlorides may affect the results. • The effect of the concrete condition (dry or wet), presence of chloride, absence of oxygen at the rebar surface (due to saturation), cover thickness, concrete resistivity, and temperature are all factors that can influence the results by shifting their potential reading towards a more positive or negative value as shown in following table.
  • 55. Conditions Potential values (mV/CSE*) Humid, chloride free concrete -200 to +100 Wet, chloride contaminated concrete -600 to -400 Water saturated concrete without oxygen -1000 to -900 Humid, carbonated concrete -400 to +100 Dry, carbonated concrete 0 to +200 Dry concrete 0 to +200 Typical ranges of half-cell potentials of rebar in concrete (adapted from RILEM TC-154, 2003)
  • 56. In addition, half-cell measurement is considered to be a zonal measurement as it will take an average potential measurement of the surroundings. An example is illustrated in Figure 3, where the measured potential will show sort of an average over a certain distance and where the actual location of the corroded bar can be challenging to distinguish, even with corrosion potential mapping.
  • 57. Nevertheless, this technique is being widely used since it is the only corrosion monitoring technique standardized by ASTM. It can be very useful in doing a quick assessment and identifying the regions where there might be a relatively higher corrosion activity. It remains that the corrosion potential technique's output is qualitative as it provides information only on the chance of corrosion activity, not quantitative information such as the rate at which the rebar is corroding; this is more useful information when it comes to determining the plan of action for repair or corrosion mitigation.
  • 58. Resistivity Measurement • Resistivity Mapping: • The electrical resistance of concrete plays an important role in determining the quality of concrete from the point of view ‘corrosion susceptibility potential’ at any specific location. This parameter is expressed in terms of “Resistivity” in ohm-cm. • For general monitoring, a resistivity check is important because long-term corrosion can be anticipated in concrete structures where accurately measured values are below 10,000 ohm- cm.Further, if resistivity values fall below 5,000 ohm-cm, corrosion must be anticipated at a much earlier period (possibly within 5 years) in the life of a structure. Table 3.14 indicates the general guidelines of resistivity values based on which areas having probable corrosion risk can be identified in concrete structures.
  • 59. • The method essentially consists of using a 4- probe technique in which a known current is applied between two outer probes 100 mm apart and the voltage drop between the inner two elements at 50 mm spacing, is read off allowing for a direct evaluation of resistance R . Using a mathematical conversion factor, resistivity is calculated as per principle of four probe resistivity testing is illustrated in Fig 3.18.
  • 60. Corrosion Probability based on Resistivity and Potential Mapping CSE – Copper Sulphate Electrode
  • 61. Fire Damage Assessment: 1. Differential Thermal Analysis (DTA) • DTA is used to study the physical and chemical changes that occur in a material when it is heated so as to characterise the material. It is concerned with the rate of change of temperature of a sample as it is heated at a constant rate of heat flow. • The principle on which DTA is based is that when a material is slowly heated, its temperature rises but when the material undergoes any endothermic reaction viz. losing water, losing CO2, change in crystalline structure or decomposition, its temperature remains constant.
  • 62. 2. X-ray Diffraction (Xrd): • X-ray Diffraction (XRD) The atomic planes of a crystal cause an incident beam of X-rays to interfere with one another as they leave the crystal. The phenomenon is called X-ray diffraction. • X-ray diffraction technique is based on the principle that a crystal of a substance has a unique diffraction pattern. • As regards to the assessment of fire damage, X-ray diffraction can be used to determine the extent of deterioration in concrete that has been subjected to fire. The temperature to which the damaged concrete has been subjected to can be determined by this method.
  • 63.
  • 64.
  • 65. • Reference : • HANDBOOK ON REPAIR AND REHABILITATION OF RCC BUILDINGS (CENTRAL PUBLIC WORKS DEPARTMENT )