SlideShare a Scribd company logo
1 of 3
Download to read offline
Designation: D 548 – 97 An American National Standard
Standard Test Method for
Water-Soluble Acidity or Alkalinity of Paper1
This standard is issued under the fixed designation D 548; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This test method covers the determination of the water-
soluble acidity or alkalinity of paper.2
1.2 It may be applied to writing, printing, and sized indus-
trial paper but is not intended for testing electrical insulating
papers nor those containing alkaline fillers or coatings such as
casein or calcium carbonate.
1.3 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use.
2. Referenced Documents
2.1 ASTM Standards:
D 585 Practice for Sampling and Accepting a Single Lot of
Paper, Paperboard, Fiberboard, or Related Product3
D 644 Test Method for Moisture Content of Paper and
Paperboard by Oven Drying3
D 1193 Specification for Reagent Water4
D 1293 Test Methods for pH of Water4
D 1968 Terminology Relating to Paper and Paper Products3
E 70 Test Method of pH of Aqueous Solutions with the
Glass Electrode5
2.2 TAPPI Standard:
T 1206 Precision statement for test methods6
3. Terminology
3.1 Definitions—Definitions shall be in accordance with
Terminology D 1968 and the Dictionary of Paper.6
4. Summary of Test Method
4.1 This test method consists of a boiling-water extraction
of the specimen followed by an alkalinity-acidity titration of
the extract solution.
4.2 This test method, based on the work of Kohler and
Hall,2
measures the titratable acidity or alkalinity (end point at
7.0 pH) of an aqueous extract of paper (filtered and extracted
by boiling water for 1 h). It specifies one extraction and so does
not measure the total acidity or alkalinity of paper, for which
exhaustive extraction is required.
5. Significance and Use
5.1 The pH determination measures the extent to which the
paper alters the hydrogen-hydroxyl ion equilibrium of pure
water, and the acidity-alkalinity determination measures the
quantity of extracted ionic material that contributes to that
equilibrium change. These tests are useful for routine accep-
tance testing, research work, or the evaluation and classifica-
tion of different papers.
6. Apparatus
6.1 pH meter, a commercial pH meter including a glass
electrode, reference electrode, and electronic circuitry that will
measure electromotive force and indicate pH directly with a
precision of 0.01 pH unit (see Fig. 1). A pH meter of Type II,
III, or IV as described in Specification D 1293 is satisfactory,
and shall be calibrated and used in accordance with Specifica-
tion E 70.
6.2 Balance, an analytical balance sensitive to 0.1 mg.
6.3 Hot Plate, with temperature regulator.
NOTE 1—A steam or oil bath that can be maintained at 100°C may be
substituted, if available.
6.4 Glassware, Acid- and Alkali-Resistant:
6.4.1 Erlenmeyer Flask, 500-mL with 24/40 standard taper
joint.
6.4.2 Condenser, West or Allihn type, with 300-mm jacket;
or an air condenser about 12 mm outside diameter and 750 mm
long; each with a 24/40 standard taper drip-tip joint.
6.4.3 Burets, two 50-mL.
6.4.4 Beaker, 400-mL.
1
This test method is under the jurisdiction of ASTM Committee D-6 on Paper
and Paper Products and is the direct responsibility of Subcommittee D06.92 on Test
Methods.
Current edition approved Dec. 10, 1997. Published November 1998. Originally
published as D 548 39T. Last previous edition D 548 – 91 (1995)e1
2
This test method is based on the method for acidity described by S. Kohler, and
G. Hall, in “Acidity in Paper,” (The Paper Industry, Vol 7, No. 7, Edward B. Fritz,
pub., October 1925, pp. 1056-1063) with some modifications developed at the
National Bureau of Standards. In this revised method, one extraction is specified
instead of the three extractions originally specified, because Kohler subsequently
found that one extraction is sufficient for classification of paper. See “Investigation
into the Determination of Acidity and Copper Number in Paper,” Meddelande 56
Statens Provingsanstalt, Stockholm, 1932. In this article, it is stated that the acid
number thus obtained is about three fourths of that obtained by three extractions.
Studies of this test method and other acidity methods are reported by B. L.
Wehmhoff, in Technical Association Papers, Technical Association of the Pulp and
Paper Industry, May 1930 and May 1931.
3
Annual Book of ASTM Standards, Vol 15.09.
4
Annual Book of ASTM Standards, Vol 11.01.
5
Annual Book of ASTM Standards, Vol 15.05.
6
Available from the Technical Association of the Pulp and Paper Industry,
Technology Park, P.O. Box 105113, Atlanta, GA 30348.
1
AMERICAN SOCIETY FOR TESTING AND MATERIALS
100 Barr Harbor Dr., West Conshohocken, PA 19428
Reprinted from the Annual Book of ASTM Standards. Copyright ASTM
NOTICE:¬This¬standard¬has¬either¬been¬superceded¬and¬replaced¬by¬a¬new¬version¬or¬discontinued.¬
Contact¬ASTM¬International¬(www.astm.org)¬for¬the¬latest¬information.¬
6.4.5 Graduated Cylinders, 100- and 250-mL.
6.5 Buchner Funnel, 60-mL, glass, with medium fritted
disk.
7. Reagents
7.1 Purity of Reagents—Reagent grade chemicals shall be
used in all tests. Unless otherwise indicated, it is intended that
all reagents shall conform to the specification of the Committee
on Analytical Reagents of the American Chemical Society,
where such specifications are available.7
Other grades may be
used, provided it is first ascertained that the reagent is of
sufficiently high purity to permit its use without lessening the
accuracy of the determination.
7.2 Hydrochloric or Sulfuric Acid, Standard Solution
(0.01N)—Prepare and standardize a 0.01N solution of hydro-
chloric acid (HCl) or sulfuric acid (H2SO4). Calculate normal-
ity to four decimal places.
7.3 Purity of Water—Unless otherwise indicated, references
to water shall be understood to mean freshly boiled and cooled
reagent water, Type I or II, as described in Specification
D 1193.
7.4 Sodium Hydroxide, Standard Solution (0.01N)—Prepare
and standardize a 0.01N solution of NaOH. Calculate normality
to four decimal places.
7.5 Carbon Dioxide-Free Gas, Nitrogen, or Purified Air—
Air, if used, should be oil-free. Pass the air through a gas
washing bottle containing at least 200 mL of 3N H2SO4 and
through a tower or U-tube containing ascarite or soda lime, 120
to 150 mm long, before connecting to the gas dispensing tube.
8. Sampling
8.1 Sample the material to be tested in accordance with
Methods D 585.
9. Test Specimen
9.1 From each test unit of the sample, cut three representa-
tive test specimens of approximately 20 g each.
9.2 Cut each specimen into 5 to 10-mm squares with a pair
of scissors.
10. Procedure
10.1 Allow the prepared test specimen to reach moisture
equilibrium with the atmosphere of the balance case.
10.2 Weigh two 5-g portions to the nearest 1 mg for
extraction.
10.3 At the same time, and using the third prepared sample,
determine the moisture content of the material in accordance
with Test Method D 644.
10.4 Transfer the weighed portions of sample (see 10.2) to
two 500-mL Erlenmeyer flasks and add 250 mL of boiling
water to each flask. In some cases, the fibers absorb water
slowly and tend to float on the surface of the water. This may
be avoided by first adding small portions of the water and
shaking well until the fibers are thoroughly saturated.
10.5 To a third 500-mL Erlenmeyer flask add 250 mL of
boiling water. This constitutes the blank. Carry this blank
through all the remaining steps of the procedure.
10.6 After the water is added, affix a condenser to each
flask. The air condenser may be used if an oil or water bath
regulated to 100°C is used. When using a hot plate, the West or
Allihn type condenser (see 6.5.2) must be used.
10.7 Place the flask with condenser affixed on the heat
source. Allow a few minutes for the sample to come to the bath
temperature, or, in the case of the hot plate, to begin to gently
boil. Maintain temperature for 60 6 5 min swirling occasion-
ally.
10.8 At the end of this period, pour the contents of the flask
into a Buchner funnel without other filtering medium. Wash the
fibers remaining in the flask into the Buchner funnel with 10
mL of hot distilled water.
10.9 Apply gentle suction.
10.10 Wash the fibers in the Buchner funnel with 25 to 50
mL of hot distilled water. Apply suction to complete the
filtration and cool the extract rapidly in a stoppered Erlenmeyer
flask.
10.11 As soon as the extract reaches room temperature,
quantitatively transfer it to a 400-mL beaker.
10.12 Titration—Titrate the sample with standard acid or
base as follows:
10.12.1 Pass a gentle stream of nitrogen or carbon dioxide-
free air through the extract (or blank) as shown in Fig. 1.
Continue to sweep the sample with nitrogen or carbon dioxide-
free air during the entire titration.
10.12.2 Follow the manufacturer’s instructions for operat-
ing the pH meter, or consult Test Methods D 1293 or Test
Method E 70.
7
“Reagent Chemicals, American Chemical Society Specifications,” Am. Chem.
Soc., Washington, DC. For suggestions on the testing of reagents not listed by the
American Chemical Society, see “Reagent Chemicals and Standards,” by Joseph
Rosin, D. Van Nostrand Co., Inc., New York, NY and the “United States
Pharmacopeia.”
FIG. 1 pH Meter Assembly
D 548
2
NOTICE:¬This¬standard¬has¬either¬been¬superceded¬and¬replaced¬by¬a¬new¬version¬or¬discontinued.¬
Contact¬ASTM¬International¬(www.astm.org)¬for¬the¬latest¬information.¬
10.12.3 Using a pH meter, determine the pH of the extract
(or blank). If the initial pH is below 7.0, the extract (or blank)
is acidic, and the titration is done with the standardized sodium
hydroxide. If the initial pH is above 7.0, the extract (or blank)
is alkaline, and the titration is done with standardized hydro-
chloric or sulfuric acid.
10.12.4 Using a pH meter, titrate with acid or alkali to a pH
of 7.0, while passing nitrogen or CO2-free air through the
specimen as shown in Fig. 1. Follow the manufacturers
instructions for operating the pH meter, or consult Test
Methods D 1293 or Test Method E 70.
11. Calculations
11.1 Calculate milliequivalents of acid or base consumed
per gram, as follows:
11.1.1 For each extract (or blank), calculate the milliequiva-
lents of reagent (standard acid or standard base) consumed as
follows:
milliequivalents of reagent consumed 5 V 3 N (1)
where:
V 5 reagent required to reach pH 7.0, mL, and
N 5 normality of the reagent used.
11.1.2 Correct the milliequivalents of reagent (acid or base)
consumed by the sample for the blank titration as follows:
11.1.2.1 If the sample extract and the blank are both acidic
or both alkaline, subtract the milliequivalents of the blank from
the milliequivalents of the sample.
11.1.2.2 If the sample extract is alkaline and the blank is
acidic, or the sample extract is acidic and the blank is alkaline,
add the milliequivalents of the blank to the milliequivalents of
the sample extract.
11.1.3 Calculate the milliequivalents of acidity or alkalinity
per gram for each sample by dividing the corrected mil-
liequivalents by the sample weight (see 10.2) corrected for
moisture (see 10.3).
11.2 Calculate as percent SO3 or percent NaOH present.
11.2.1 Where the calculation for 11.1 shows the sample to
be acidic (that is the original sample pH was below 7.0 (see
10.12.3)) calculate SO3 present as:
SO3, % 5
milliequivalents of base consumed 3 0.040
W 3 100 (2)
where:
W 5 sample weight (10.2) corrected for moisture (10.3).
NOTE 2—If the sample is originally acidic (original pH less than 7) the
milliequivalents calculated are those of the base used in titration. The
milliequivalents of base used (corrected for the blank) are numerically
equal to the milliequivalents of acid in the original sample.
NOTE 3—If the sample is originally basic (original pH greater than 7)
the milliequivalents calculated are the acid used in titration. The mil-
liequivalents of acid used (corrected for the blank) are numerically equal
to the milliequivalents of base in the original sample.
11.2.2 Where the calculation in 11.1 shows the sample to be
basic (that is the original sample pH was above 7.0 (see
10.12.3)) calculate percent NaOH as:
NaOH, % 5
milliequivalents of acid consumed 3 0.040
W 3 100
(3)
where:
W 5 sample weight (10.2) corrected for moisture (10.3).
11.3 The milliequivalents of acid consumed (11.2) is nu-
merically equivalent to the milliequivalents of base present in
the sample. Likewise, the milliequivalents of base consumed
(11.2) is numerically equivalent to the milliequivalent of acid
present in the sample.
12. Report
12.1 The milliequivalents of acid or base present in the
sample, or the percent alkalinity as calculated in 11.2 may be
reported, as agreed by parties involved in the testing.
13. Precision
13.1 Repeatability (Within a Laboratory)—Duplicate test
determinations on low-acidity paper on each of three different
days in one laboratory agreed to 0.01 % acidity. It is estimated
from this limited information that repeatability of test results
for low-acidity paper would be about 0.02 % acidity.
13.2 The reproducibility (between laboratories) is not
known.
13.3 The above terms are used in accordance with the
definitions in TAPPI T1206.
14. Keywords
14.1 paper products; water-soluble acidity; water-soluble
alkalinity
The American Society for Testing and Materials takes no position respecting the validity of any patent rights asserted in connection
with any item mentioned in this standard. Users of this standard are expressly advised that determination of the validity of any such
patent rights, and the risk of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM Headquarters. Your comments will receive careful consideration at a meeting of the responsible
technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should make your
views known to the ASTM Committee on Standards, 100 Barr Harbor Drive, West Conshohocken, PA 19428.
D 548
3
NOTICE:¬This¬standard¬has¬either¬been¬superceded¬and¬replaced¬by¬a¬new¬version¬or¬discontinued.¬
Contact¬ASTM¬International¬(www.astm.org)¬for¬the¬latest¬information.¬

More Related Content

What's hot

4 lab-tss-tds-vss
4 lab-tss-tds-vss4 lab-tss-tds-vss
4 lab-tss-tds-vssTAMUK
 
Chemical Tests - PDW final 2.11.2014
Chemical Tests - PDW final 2.11.2014Chemical Tests - PDW final 2.11.2014
Chemical Tests - PDW final 2.11.2014SATISH KUMAR
 
Laboratory reagent water
Laboratory reagent waterLaboratory reagent water
Laboratory reagent waterVinay Shukla
 
Qualitycontroltestforpackagingmaterialppt 181208041612
Qualitycontroltestforpackagingmaterialppt 181208041612Qualitycontroltestforpackagingmaterialppt 181208041612
Qualitycontroltestforpackagingmaterialppt 181208041612Ravi kumar
 
Solid matter 1
Solid matter 1Solid matter 1
Solid matter 1Raz Azad
 
Lec 4 solids environment
Lec 4 solids environmentLec 4 solids environment
Lec 4 solids environmentMalika khalil
 
Chapter 2
Chapter 2Chapter 2
Chapter 2MEI MEI
 
Calibration,Quality & Type of Glassware
Calibration,Quality & Type of GlasswareCalibration,Quality & Type of Glassware
Calibration,Quality & Type of Glasswaresaba Rafiq
 
OTL: New Fire Sample Testing & Fire Fighting Foams Brochure
OTL: New Fire Sample Testing & Fire Fighting Foams BrochureOTL: New Fire Sample Testing & Fire Fighting Foams Brochure
OTL: New Fire Sample Testing & Fire Fighting Foams BrochureDavid Holmes
 
Item 7 :Comparación de los *SOPs entre LATSOLAN y **SEALNET
Item 7 :Comparación de los *SOPs entre LATSOLAN y **SEALNETItem 7 :Comparación de los *SOPs entre LATSOLAN y **SEALNET
Item 7 :Comparación de los *SOPs entre LATSOLAN y **SEALNETExternalEvents
 
Examining Simplified Shelf Life Testing Methods
Examining Simplified Shelf Life Testing MethodsExamining Simplified Shelf Life Testing Methods
Examining Simplified Shelf Life Testing MethodsMETER Group, Inc. USA
 
DISSOLUTION TESTING APPARATUS
DISSOLUTION TESTING APPARATUSDISSOLUTION TESTING APPARATUS
DISSOLUTION TESTING APPARATUSBushra S
 
Stability Of Drug Eluting Stents
Stability Of Drug Eluting StentsStability Of Drug Eluting Stents
Stability Of Drug Eluting Stentsmaschreib
 

What's hot (18)

Report waste water
Report waste waterReport waste water
Report waste water
 
4 lab-tss-tds-vss
4 lab-tss-tds-vss4 lab-tss-tds-vss
4 lab-tss-tds-vss
 
water analysis sop
water analysis sopwater analysis sop
water analysis sop
 
Chemical Tests - PDW final 2.11.2014
Chemical Tests - PDW final 2.11.2014Chemical Tests - PDW final 2.11.2014
Chemical Tests - PDW final 2.11.2014
 
Sop water analysis-2
Sop water analysis-2Sop water analysis-2
Sop water analysis-2
 
Laboratory reagent water
Laboratory reagent waterLaboratory reagent water
Laboratory reagent water
 
Qualitycontroltestforpackagingmaterialppt 181208041612
Qualitycontroltestforpackagingmaterialppt 181208041612Qualitycontroltestforpackagingmaterialppt 181208041612
Qualitycontroltestforpackagingmaterialppt 181208041612
 
Solid matter 1
Solid matter 1Solid matter 1
Solid matter 1
 
validation process
  validation process  validation process
validation process
 
Lec 4 solids environment
Lec 4 solids environmentLec 4 solids environment
Lec 4 solids environment
 
Chapter 2
Chapter 2Chapter 2
Chapter 2
 
Aerosols q c
Aerosols q cAerosols q c
Aerosols q c
 
Calibration,Quality & Type of Glassware
Calibration,Quality & Type of GlasswareCalibration,Quality & Type of Glassware
Calibration,Quality & Type of Glassware
 
OTL: New Fire Sample Testing & Fire Fighting Foams Brochure
OTL: New Fire Sample Testing & Fire Fighting Foams BrochureOTL: New Fire Sample Testing & Fire Fighting Foams Brochure
OTL: New Fire Sample Testing & Fire Fighting Foams Brochure
 
Item 7 :Comparación de los *SOPs entre LATSOLAN y **SEALNET
Item 7 :Comparación de los *SOPs entre LATSOLAN y **SEALNETItem 7 :Comparación de los *SOPs entre LATSOLAN y **SEALNET
Item 7 :Comparación de los *SOPs entre LATSOLAN y **SEALNET
 
Examining Simplified Shelf Life Testing Methods
Examining Simplified Shelf Life Testing MethodsExamining Simplified Shelf Life Testing Methods
Examining Simplified Shelf Life Testing Methods
 
DISSOLUTION TESTING APPARATUS
DISSOLUTION TESTING APPARATUSDISSOLUTION TESTING APPARATUS
DISSOLUTION TESTING APPARATUS
 
Stability Of Drug Eluting Stents
Stability Of Drug Eluting StentsStability Of Drug Eluting Stents
Stability Of Drug Eluting Stents
 

Viewers also liked

carrier after b tech
carrier after b techcarrier after b tech
carrier after b techMAHESH SONI
 
Design project one - full b rief
Design   project one - full b riefDesign   project one - full b rief
Design project one - full b riefClement Seong
 
D 585 – 97 r02 ;rdu4 nq _
D 585 – 97 r02  ;rdu4 nq _D 585 – 97 r02  ;rdu4 nq _
D 585 – 97 r02 ;rdu4 nq _hamfrost
 
Oral presentation individual (a)
Oral presentation individual (a)Oral presentation individual (a)
Oral presentation individual (a)Clement Seong
 
Cncbrief2092014sept 150210065641-conversion-gate02
Cncbrief2092014sept 150210065641-conversion-gate02Cncbrief2092014sept 150210065641-conversion-gate02
Cncbrief2092014sept 150210065641-conversion-gate02Clement Seong
 
Squire Presentation
Squire PresentationSquire Presentation
Squire Presentationsreinhold
 
BA. Reseptor Asetilkolin Muskarinik (by. Ariiq Azmi RS)
BA. Reseptor Asetilkolin Muskarinik (by. Ariiq Azmi RS)BA. Reseptor Asetilkolin Muskarinik (by. Ariiq Azmi RS)
BA. Reseptor Asetilkolin Muskarinik (by. Ariiq Azmi RS)Ariiq Azmi RS
 
SNEDDS - Journal Review
SNEDDS - Journal ReviewSNEDDS - Journal Review
SNEDDS - Journal ReviewAriiq Azmi RS
 
ANALYSIS OF ECG SIGNAL USING SELF ORGANISING MAP
ANALYSIS OF ECG SIGNAL USING SELF ORGANISING MAPANALYSIS OF ECG SIGNAL USING SELF ORGANISING MAP
ANALYSIS OF ECG SIGNAL USING SELF ORGANISING MAPMAHESH SONI
 
Railway workshop jodhpur
Railway workshop jodhpurRailway workshop jodhpur
Railway workshop jodhpurMAHESH SONI
 
Plcc presentation
Plcc presentationPlcc presentation
Plcc presentationMAHESH SONI
 
Mahesh persentation bhel bhopal
Mahesh persentation bhel bhopalMahesh persentation bhel bhopal
Mahesh persentation bhel bhopalMAHESH SONI
 

Viewers also liked (13)

carrier after b tech
carrier after b techcarrier after b tech
carrier after b tech
 
Design project one - full b rief
Design   project one - full b riefDesign   project one - full b rief
Design project one - full b rief
 
D 585 – 97 r02 ;rdu4 nq _
D 585 – 97 r02  ;rdu4 nq _D 585 – 97 r02  ;rdu4 nq _
D 585 – 97 r02 ;rdu4 nq _
 
Oral presentation individual (a)
Oral presentation individual (a)Oral presentation individual (a)
Oral presentation individual (a)
 
Cncbrief2092014sept 150210065641-conversion-gate02
Cncbrief2092014sept 150210065641-conversion-gate02Cncbrief2092014sept 150210065641-conversion-gate02
Cncbrief2092014sept 150210065641-conversion-gate02
 
Squire Presentation
Squire PresentationSquire Presentation
Squire Presentation
 
BA. Reseptor Asetilkolin Muskarinik (by. Ariiq Azmi RS)
BA. Reseptor Asetilkolin Muskarinik (by. Ariiq Azmi RS)BA. Reseptor Asetilkolin Muskarinik (by. Ariiq Azmi RS)
BA. Reseptor Asetilkolin Muskarinik (by. Ariiq Azmi RS)
 
8086
80868086
8086
 
SNEDDS - Journal Review
SNEDDS - Journal ReviewSNEDDS - Journal Review
SNEDDS - Journal Review
 
ANALYSIS OF ECG SIGNAL USING SELF ORGANISING MAP
ANALYSIS OF ECG SIGNAL USING SELF ORGANISING MAPANALYSIS OF ECG SIGNAL USING SELF ORGANISING MAP
ANALYSIS OF ECG SIGNAL USING SELF ORGANISING MAP
 
Railway workshop jodhpur
Railway workshop jodhpurRailway workshop jodhpur
Railway workshop jodhpur
 
Plcc presentation
Plcc presentationPlcc presentation
Plcc presentation
 
Mahesh persentation bhel bhopal
Mahesh persentation bhel bhopalMahesh persentation bhel bhopal
Mahesh persentation bhel bhopal
 

Similar to D 548 – 97 ;rdu0 oc05nw _

Analysis of Volatile Organic Compounds (VOCs) in Air Using US EPA Method TO-17
Analysis of Volatile Organic Compounds (VOCs) in Air Using US EPA Method TO-17Analysis of Volatile Organic Compounds (VOCs) in Air Using US EPA Method TO-17
Analysis of Volatile Organic Compounds (VOCs) in Air Using US EPA Method TO-17PerkinElmer, Inc.
 
Analysis of Volatile Organic Compounds (VOCs) in Air Using U.S. EPA Method TO-17
Analysis of Volatile Organic Compounds (VOCs) in Air Using U.S. EPA Method TO-17Analysis of Volatile Organic Compounds (VOCs) in Air Using U.S. EPA Method TO-17
Analysis of Volatile Organic Compounds (VOCs) in Air Using U.S. EPA Method TO-17PerkinElmer, Inc.
 
Analysis of Volatile Organic Compounds (VOCs) in Air Using US EPA Method TO-17
Analysis of Volatile Organic Compounds (VOCs) in Air Using US EPA Method TO-17Analysis of Volatile Organic Compounds (VOCs) in Air Using US EPA Method TO-17
Analysis of Volatile Organic Compounds (VOCs) in Air Using US EPA Method TO-17PerkinElmer, Inc.
 
F 619 03 3b_rjyxoq__
F 619   03   3b_rjyxoq__F 619   03   3b_rjyxoq__
F 619 03 3b_rjyxoq__Luis Guzman
 
Sawyer_Testing_Bucket-Report
Sawyer_Testing_Bucket-ReportSawyer_Testing_Bucket-Report
Sawyer_Testing_Bucket-ReportJanelle Veazey
 
Sawyer_Testing_All-in-One-Report
Sawyer_Testing_All-in-One-ReportSawyer_Testing_All-in-One-Report
Sawyer_Testing_All-in-One-ReportJanelle Veazey
 
Sawyer-Mini-Testing-Report
Sawyer-Mini-Testing-ReportSawyer-Mini-Testing-Report
Sawyer-Mini-Testing-ReportJanelle Veazey
 
Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling
 Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling
Download-manuals-surface water-manual-sw-volume6fieldmanualwqsamplinghydrologyproject001
 
Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling
 Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling
Download-manuals-surface water-manual-sw-volume6fieldmanualwqsamplinghydrologyproject001
 
Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling
 Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling
Download-manuals-surface water-manual-sw-volume6fieldmanualwqsamplinghydrologywebsite1
 
Chemical Oxygen Demand
Chemical Oxygen DemandChemical Oxygen Demand
Chemical Oxygen DemandMuhd Effandi
 
Lignocellulose Biomass- Hydrolysis & Fermentation Lab Protocols
Lignocellulose Biomass- Hydrolysis & Fermentation Lab ProtocolsLignocellulose Biomass- Hydrolysis & Fermentation Lab Protocols
Lignocellulose Biomass- Hydrolysis & Fermentation Lab ProtocolsBiorefineryEPC™
 
253651195 astm-c939
253651195 astm-c939253651195 astm-c939
253651195 astm-c939Socolap Pham
 
Using THGA and Zeeman Background Correction for Blood-Lead Determination in C...
Using THGA and Zeeman Background Correction for Blood-Lead Determination in C...Using THGA and Zeeman Background Correction for Blood-Lead Determination in C...
Using THGA and Zeeman Background Correction for Blood-Lead Determination in C...PerkinElmer, Inc.
 
Headspace Gas Chromatograph/PID for Onsite Screening of Soil and Water at Haz...
Headspace Gas Chromatograph/PID for Onsite Screening of Soil and Water at Haz...Headspace Gas Chromatograph/PID for Onsite Screening of Soil and Water at Haz...
Headspace Gas Chromatograph/PID for Onsite Screening of Soil and Water at Haz...Jennifer Maclachlan
 
Quality control of packaging material.pptx
Quality control of packaging material.pptxQuality control of packaging material.pptx
Quality control of packaging material.pptxEasy Concept
 

Similar to D 548 – 97 ;rdu0 oc05nw _ (20)

Epa 7.1
Epa 7.1Epa 7.1
Epa 7.1
 
Analysis of Volatile Organic Compounds (VOCs) in Air Using US EPA Method TO-17
Analysis of Volatile Organic Compounds (VOCs) in Air Using US EPA Method TO-17Analysis of Volatile Organic Compounds (VOCs) in Air Using US EPA Method TO-17
Analysis of Volatile Organic Compounds (VOCs) in Air Using US EPA Method TO-17
 
Analysis of Volatile Organic Compounds (VOCs) in Air Using U.S. EPA Method TO-17
Analysis of Volatile Organic Compounds (VOCs) in Air Using U.S. EPA Method TO-17Analysis of Volatile Organic Compounds (VOCs) in Air Using U.S. EPA Method TO-17
Analysis of Volatile Organic Compounds (VOCs) in Air Using U.S. EPA Method TO-17
 
Analysis of Volatile Organic Compounds (VOCs) in Air Using US EPA Method TO-17
Analysis of Volatile Organic Compounds (VOCs) in Air Using US EPA Method TO-17Analysis of Volatile Organic Compounds (VOCs) in Air Using US EPA Method TO-17
Analysis of Volatile Organic Compounds (VOCs) in Air Using US EPA Method TO-17
 
D2584.21532.pdf
D2584.21532.pdfD2584.21532.pdf
D2584.21532.pdf
 
F 619 03 3b_rjyxoq__
F 619   03   3b_rjyxoq__F 619   03   3b_rjyxoq__
F 619 03 3b_rjyxoq__
 
Sawyer_Testing_Bucket-Report
Sawyer_Testing_Bucket-ReportSawyer_Testing_Bucket-Report
Sawyer_Testing_Bucket-Report
 
Sawyer_Testing_All-in-One-Report
Sawyer_Testing_All-in-One-ReportSawyer_Testing_All-in-One-Report
Sawyer_Testing_All-in-One-Report
 
D4943 astm
D4943 astmD4943 astm
D4943 astm
 
Sawyer-Mini-Testing-Report
Sawyer-Mini-Testing-ReportSawyer-Mini-Testing-Report
Sawyer-Mini-Testing-Report
 
Environment us-web
Environment us-webEnvironment us-web
Environment us-web
 
Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling
 Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling
Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling
 
Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling
 Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling
Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling
 
Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling
 Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling
Download-manuals-surface water-manual-sw-volume6fieldmanualwqsampling
 
Chemical Oxygen Demand
Chemical Oxygen DemandChemical Oxygen Demand
Chemical Oxygen Demand
 
Lignocellulose Biomass- Hydrolysis & Fermentation Lab Protocols
Lignocellulose Biomass- Hydrolysis & Fermentation Lab ProtocolsLignocellulose Biomass- Hydrolysis & Fermentation Lab Protocols
Lignocellulose Biomass- Hydrolysis & Fermentation Lab Protocols
 
253651195 astm-c939
253651195 astm-c939253651195 astm-c939
253651195 astm-c939
 
Using THGA and Zeeman Background Correction for Blood-Lead Determination in C...
Using THGA and Zeeman Background Correction for Blood-Lead Determination in C...Using THGA and Zeeman Background Correction for Blood-Lead Determination in C...
Using THGA and Zeeman Background Correction for Blood-Lead Determination in C...
 
Headspace Gas Chromatograph/PID for Onsite Screening of Soil and Water at Haz...
Headspace Gas Chromatograph/PID for Onsite Screening of Soil and Water at Haz...Headspace Gas Chromatograph/PID for Onsite Screening of Soil and Water at Haz...
Headspace Gas Chromatograph/PID for Onsite Screening of Soil and Water at Haz...
 
Quality control of packaging material.pptx
Quality control of packaging material.pptxQuality control of packaging material.pptx
Quality control of packaging material.pptx
 

D 548 – 97 ;rdu0 oc05nw _

  • 1. Designation: D 548 – 97 An American National Standard Standard Test Method for Water-Soluble Acidity or Alkalinity of Paper1 This standard is issued under the fixed designation D 548; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript epsilon (e) indicates an editorial change since the last revision or reapproval. 1. Scope 1.1 This test method covers the determination of the water- soluble acidity or alkalinity of paper.2 1.2 It may be applied to writing, printing, and sized indus- trial paper but is not intended for testing electrical insulating papers nor those containing alkaline fillers or coatings such as casein or calcium carbonate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro- priate safety and health practices and determine the applica- bility of regulatory limitations prior to use. 2. Referenced Documents 2.1 ASTM Standards: D 585 Practice for Sampling and Accepting a Single Lot of Paper, Paperboard, Fiberboard, or Related Product3 D 644 Test Method for Moisture Content of Paper and Paperboard by Oven Drying3 D 1193 Specification for Reagent Water4 D 1293 Test Methods for pH of Water4 D 1968 Terminology Relating to Paper and Paper Products3 E 70 Test Method of pH of Aqueous Solutions with the Glass Electrode5 2.2 TAPPI Standard: T 1206 Precision statement for test methods6 3. Terminology 3.1 Definitions—Definitions shall be in accordance with Terminology D 1968 and the Dictionary of Paper.6 4. Summary of Test Method 4.1 This test method consists of a boiling-water extraction of the specimen followed by an alkalinity-acidity titration of the extract solution. 4.2 This test method, based on the work of Kohler and Hall,2 measures the titratable acidity or alkalinity (end point at 7.0 pH) of an aqueous extract of paper (filtered and extracted by boiling water for 1 h). It specifies one extraction and so does not measure the total acidity or alkalinity of paper, for which exhaustive extraction is required. 5. Significance and Use 5.1 The pH determination measures the extent to which the paper alters the hydrogen-hydroxyl ion equilibrium of pure water, and the acidity-alkalinity determination measures the quantity of extracted ionic material that contributes to that equilibrium change. These tests are useful for routine accep- tance testing, research work, or the evaluation and classifica- tion of different papers. 6. Apparatus 6.1 pH meter, a commercial pH meter including a glass electrode, reference electrode, and electronic circuitry that will measure electromotive force and indicate pH directly with a precision of 0.01 pH unit (see Fig. 1). A pH meter of Type II, III, or IV as described in Specification D 1293 is satisfactory, and shall be calibrated and used in accordance with Specifica- tion E 70. 6.2 Balance, an analytical balance sensitive to 0.1 mg. 6.3 Hot Plate, with temperature regulator. NOTE 1—A steam or oil bath that can be maintained at 100°C may be substituted, if available. 6.4 Glassware, Acid- and Alkali-Resistant: 6.4.1 Erlenmeyer Flask, 500-mL with 24/40 standard taper joint. 6.4.2 Condenser, West or Allihn type, with 300-mm jacket; or an air condenser about 12 mm outside diameter and 750 mm long; each with a 24/40 standard taper drip-tip joint. 6.4.3 Burets, two 50-mL. 6.4.4 Beaker, 400-mL. 1 This test method is under the jurisdiction of ASTM Committee D-6 on Paper and Paper Products and is the direct responsibility of Subcommittee D06.92 on Test Methods. Current edition approved Dec. 10, 1997. Published November 1998. Originally published as D 548 39T. Last previous edition D 548 – 91 (1995)e1 2 This test method is based on the method for acidity described by S. Kohler, and G. Hall, in “Acidity in Paper,” (The Paper Industry, Vol 7, No. 7, Edward B. Fritz, pub., October 1925, pp. 1056-1063) with some modifications developed at the National Bureau of Standards. In this revised method, one extraction is specified instead of the three extractions originally specified, because Kohler subsequently found that one extraction is sufficient for classification of paper. See “Investigation into the Determination of Acidity and Copper Number in Paper,” Meddelande 56 Statens Provingsanstalt, Stockholm, 1932. In this article, it is stated that the acid number thus obtained is about three fourths of that obtained by three extractions. Studies of this test method and other acidity methods are reported by B. L. Wehmhoff, in Technical Association Papers, Technical Association of the Pulp and Paper Industry, May 1930 and May 1931. 3 Annual Book of ASTM Standards, Vol 15.09. 4 Annual Book of ASTM Standards, Vol 11.01. 5 Annual Book of ASTM Standards, Vol 15.05. 6 Available from the Technical Association of the Pulp and Paper Industry, Technology Park, P.O. Box 105113, Atlanta, GA 30348. 1 AMERICAN SOCIETY FOR TESTING AND MATERIALS 100 Barr Harbor Dr., West Conshohocken, PA 19428 Reprinted from the Annual Book of ASTM Standards. Copyright ASTM NOTICE:¬This¬standard¬has¬either¬been¬superceded¬and¬replaced¬by¬a¬new¬version¬or¬discontinued.¬ Contact¬ASTM¬International¬(www.astm.org)¬for¬the¬latest¬information.¬
  • 2. 6.4.5 Graduated Cylinders, 100- and 250-mL. 6.5 Buchner Funnel, 60-mL, glass, with medium fritted disk. 7. Reagents 7.1 Purity of Reagents—Reagent grade chemicals shall be used in all tests. Unless otherwise indicated, it is intended that all reagents shall conform to the specification of the Committee on Analytical Reagents of the American Chemical Society, where such specifications are available.7 Other grades may be used, provided it is first ascertained that the reagent is of sufficiently high purity to permit its use without lessening the accuracy of the determination. 7.2 Hydrochloric or Sulfuric Acid, Standard Solution (0.01N)—Prepare and standardize a 0.01N solution of hydro- chloric acid (HCl) or sulfuric acid (H2SO4). Calculate normal- ity to four decimal places. 7.3 Purity of Water—Unless otherwise indicated, references to water shall be understood to mean freshly boiled and cooled reagent water, Type I or II, as described in Specification D 1193. 7.4 Sodium Hydroxide, Standard Solution (0.01N)—Prepare and standardize a 0.01N solution of NaOH. Calculate normality to four decimal places. 7.5 Carbon Dioxide-Free Gas, Nitrogen, or Purified Air— Air, if used, should be oil-free. Pass the air through a gas washing bottle containing at least 200 mL of 3N H2SO4 and through a tower or U-tube containing ascarite or soda lime, 120 to 150 mm long, before connecting to the gas dispensing tube. 8. Sampling 8.1 Sample the material to be tested in accordance with Methods D 585. 9. Test Specimen 9.1 From each test unit of the sample, cut three representa- tive test specimens of approximately 20 g each. 9.2 Cut each specimen into 5 to 10-mm squares with a pair of scissors. 10. Procedure 10.1 Allow the prepared test specimen to reach moisture equilibrium with the atmosphere of the balance case. 10.2 Weigh two 5-g portions to the nearest 1 mg for extraction. 10.3 At the same time, and using the third prepared sample, determine the moisture content of the material in accordance with Test Method D 644. 10.4 Transfer the weighed portions of sample (see 10.2) to two 500-mL Erlenmeyer flasks and add 250 mL of boiling water to each flask. In some cases, the fibers absorb water slowly and tend to float on the surface of the water. This may be avoided by first adding small portions of the water and shaking well until the fibers are thoroughly saturated. 10.5 To a third 500-mL Erlenmeyer flask add 250 mL of boiling water. This constitutes the blank. Carry this blank through all the remaining steps of the procedure. 10.6 After the water is added, affix a condenser to each flask. The air condenser may be used if an oil or water bath regulated to 100°C is used. When using a hot plate, the West or Allihn type condenser (see 6.5.2) must be used. 10.7 Place the flask with condenser affixed on the heat source. Allow a few minutes for the sample to come to the bath temperature, or, in the case of the hot plate, to begin to gently boil. Maintain temperature for 60 6 5 min swirling occasion- ally. 10.8 At the end of this period, pour the contents of the flask into a Buchner funnel without other filtering medium. Wash the fibers remaining in the flask into the Buchner funnel with 10 mL of hot distilled water. 10.9 Apply gentle suction. 10.10 Wash the fibers in the Buchner funnel with 25 to 50 mL of hot distilled water. Apply suction to complete the filtration and cool the extract rapidly in a stoppered Erlenmeyer flask. 10.11 As soon as the extract reaches room temperature, quantitatively transfer it to a 400-mL beaker. 10.12 Titration—Titrate the sample with standard acid or base as follows: 10.12.1 Pass a gentle stream of nitrogen or carbon dioxide- free air through the extract (or blank) as shown in Fig. 1. Continue to sweep the sample with nitrogen or carbon dioxide- free air during the entire titration. 10.12.2 Follow the manufacturer’s instructions for operat- ing the pH meter, or consult Test Methods D 1293 or Test Method E 70. 7 “Reagent Chemicals, American Chemical Society Specifications,” Am. Chem. Soc., Washington, DC. For suggestions on the testing of reagents not listed by the American Chemical Society, see “Reagent Chemicals and Standards,” by Joseph Rosin, D. Van Nostrand Co., Inc., New York, NY and the “United States Pharmacopeia.” FIG. 1 pH Meter Assembly D 548 2 NOTICE:¬This¬standard¬has¬either¬been¬superceded¬and¬replaced¬by¬a¬new¬version¬or¬discontinued.¬ Contact¬ASTM¬International¬(www.astm.org)¬for¬the¬latest¬information.¬
  • 3. 10.12.3 Using a pH meter, determine the pH of the extract (or blank). If the initial pH is below 7.0, the extract (or blank) is acidic, and the titration is done with the standardized sodium hydroxide. If the initial pH is above 7.0, the extract (or blank) is alkaline, and the titration is done with standardized hydro- chloric or sulfuric acid. 10.12.4 Using a pH meter, titrate with acid or alkali to a pH of 7.0, while passing nitrogen or CO2-free air through the specimen as shown in Fig. 1. Follow the manufacturers instructions for operating the pH meter, or consult Test Methods D 1293 or Test Method E 70. 11. Calculations 11.1 Calculate milliequivalents of acid or base consumed per gram, as follows: 11.1.1 For each extract (or blank), calculate the milliequiva- lents of reagent (standard acid or standard base) consumed as follows: milliequivalents of reagent consumed 5 V 3 N (1) where: V 5 reagent required to reach pH 7.0, mL, and N 5 normality of the reagent used. 11.1.2 Correct the milliequivalents of reagent (acid or base) consumed by the sample for the blank titration as follows: 11.1.2.1 If the sample extract and the blank are both acidic or both alkaline, subtract the milliequivalents of the blank from the milliequivalents of the sample. 11.1.2.2 If the sample extract is alkaline and the blank is acidic, or the sample extract is acidic and the blank is alkaline, add the milliequivalents of the blank to the milliequivalents of the sample extract. 11.1.3 Calculate the milliequivalents of acidity or alkalinity per gram for each sample by dividing the corrected mil- liequivalents by the sample weight (see 10.2) corrected for moisture (see 10.3). 11.2 Calculate as percent SO3 or percent NaOH present. 11.2.1 Where the calculation for 11.1 shows the sample to be acidic (that is the original sample pH was below 7.0 (see 10.12.3)) calculate SO3 present as: SO3, % 5 milliequivalents of base consumed 3 0.040 W 3 100 (2) where: W 5 sample weight (10.2) corrected for moisture (10.3). NOTE 2—If the sample is originally acidic (original pH less than 7) the milliequivalents calculated are those of the base used in titration. The milliequivalents of base used (corrected for the blank) are numerically equal to the milliequivalents of acid in the original sample. NOTE 3—If the sample is originally basic (original pH greater than 7) the milliequivalents calculated are the acid used in titration. The mil- liequivalents of acid used (corrected for the blank) are numerically equal to the milliequivalents of base in the original sample. 11.2.2 Where the calculation in 11.1 shows the sample to be basic (that is the original sample pH was above 7.0 (see 10.12.3)) calculate percent NaOH as: NaOH, % 5 milliequivalents of acid consumed 3 0.040 W 3 100 (3) where: W 5 sample weight (10.2) corrected for moisture (10.3). 11.3 The milliequivalents of acid consumed (11.2) is nu- merically equivalent to the milliequivalents of base present in the sample. Likewise, the milliequivalents of base consumed (11.2) is numerically equivalent to the milliequivalent of acid present in the sample. 12. Report 12.1 The milliequivalents of acid or base present in the sample, or the percent alkalinity as calculated in 11.2 may be reported, as agreed by parties involved in the testing. 13. Precision 13.1 Repeatability (Within a Laboratory)—Duplicate test determinations on low-acidity paper on each of three different days in one laboratory agreed to 0.01 % acidity. It is estimated from this limited information that repeatability of test results for low-acidity paper would be about 0.02 % acidity. 13.2 The reproducibility (between laboratories) is not known. 13.3 The above terms are used in accordance with the definitions in TAPPI T1206. 14. Keywords 14.1 paper products; water-soluble acidity; water-soluble alkalinity The American Society for Testing and Materials takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM Headquarters. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, 100 Barr Harbor Drive, West Conshohocken, PA 19428. D 548 3 NOTICE:¬This¬standard¬has¬either¬been¬superceded¬and¬replaced¬by¬a¬new¬version¬or¬discontinued.¬ Contact¬ASTM¬International¬(www.astm.org)¬for¬the¬latest¬information.¬