Hot Sexy call girls in Panjabi Bagh 🔝 9953056974 🔝 Delhi escort Service
Global
1. ReiGed
Diagnostics
Fully Automatic Biochemistry Analazer
GLOBAL 400
- Continuous Access capability, at any moment a sample can be put on and processed
- Automatic repetition with dilution of samples whose results are above linearity limit.
- Up to 60 position for reagents are available into the reagent compartment at the same time
- Primary tubes with barcode for Positive ID of samples
- 50 semi disposable plastic cuvettes for reading with thermostatic temperature control
- Sampling probe level detector for sample, either in primary tube or secondary cup
- Reading on each cuvette it`s performed with all the 9 availble wavelengths
- Friendly User Interface based on Windows XP operating system
- Reagents Sensor Level and optional Barcode Reader
ReiGed Diagnostics :
www.ReiGed-Diagnostics.com
janto@reiged-diagnostics.com jantosth@telkom.net
2. ReiGed
Diagnostics
Tecnical Specification of GLOBAL 400
Principle of Operating
Random / Continuous Access
Reading Mode
Absorbance
STAT Function
Possibility of entering and processing sample at any moment during the routine.
Type of Analysis
End point with continuous monitoring. Reagent Blank absorbance control. Kinetic reactions with Linear Regression. Sample Balnk
absorbance control. Initial Rate reaction ( 2 point kinetic ). 5 model for non linear calibrations Automatic
recalculation of calibration curves from raw data . Bi - chromatic reactions. Differential reactions ( with sample blank ).
Samples Tray
70 positions for sample in secondary cup or 40 position for primary tubes. 10 position for Calibrator and Controls.
Reagents Carousel
30 positions for mono - reagents ( 55 ml ) or bi - reagents ( 13 ml + 40 ml ) with Barcode Reader possibility, 60 positions
for single liquid reagents without Barcode Reader possibility.
Reagents cooling system.
Calibration
User definable Calibration interval linear and non - linear calibration ( up to 6 points )
Reading Carousel
50 plastic optical cuvettes ( path 0,6 mm ) - Automatic 5 steps washing station - Temperature controlled at 370 C + 0.10 C
by means of liquid circulation.
Optical System
interference Filters Photometer with available wavelengths from 340 to 700 nm ( 340 - 380 - 405 - 450 - 505 - 546 - 570 - 620 - 700 ) -
Bandwidth + 2 nm on 340 e 380 filters and + 10 nm on other filters - Absorbance`s linear from 0.0005 Abs to 2.5000 Abs.
Throughput
Max 400 tests / hour ( Global 400 )
Max 700 tests / hour (Global 400 / 700 with ISE )
Sampling System
SIP & DIP sampling system with capacitive level detector - Pre - Heating serpentine for reagents Accuracy in delivery 1 %
for steps of 1 ul.
Peripherals
Be - Directional On line interface RS 232 C.
User Interface
Indication on Display for the samples load list - Diagnostic System for technical service - Help On Line function.
Operating Environment
Environmental Temperature 150 to 320 C - , Relative Humidity : Max 70 % at 320 C.
Powwer
Volt 115/230 AC + 6%. Frequency : 50 / 60 Hz Power consumtion : 350 Watt.
Option
ISE module Na / K / Cl ( Global 400 / 700 with ISE ) : Stand Floor Cabinet ; Barcode Reader ; External Computer for
data management with software
running under Windows XP 2000 environment; Inkjek external Printer 80 columns; LCD Colour Display.
ReiGed Diagnostics :
www.ReiGed-Diagnostics.com
janto@reiged-diagnostics.com jantosth@telkom.net