                                          TEK II MINI
Auto Hematology Analyzer




                                                Registrasi Depkes RI AKL 20205900471

                           >   3 - Part differeniation of WBC ; 18 parameters + 3histograms
                           >   Double apertures for WBC and RBC / PLT
                           >   Throughput : 45samples per hour
                           >   Patented aperture technology : Automatic clog-clearing with
                               high pressure and lower rate of clog
                           >   Automatic diluting, lyzing,mixing, rinsing and clog-clearing
                           >   Automatically cleaning sampling probe
                           >   Built - intermal printer
                           >   Up to 100 test results with histogram and
                               1100 samples test results without histogram
                           >   LCD with high resolution
                           ReiGed Diagnostics :
                           www.ReiGed-Diagnostics.com
                           janto@reiged-diagnostics.com jantosth@telkom.net
ReiGed
                      Diagnostics



                                  TEK II MINI
Technical Specification
Parameters                                                             Dilution Ratione
WBC, LY#. MO#, GR#, LY%, MO% , GR%, RBC, HGB, HCT, MCV,
MCH, MCHC, RDW, PLT, MPV, PDW, PCT and Histogram for                   WBC                      1 : 500
WBC, RBC, PLT
                                                                       RBC/PLT                 1 : 40000

Method
Coulter Principle (Electrical impedance)                               Carryover
Colorimetry haemoglobin determination
                                                                       WBC. RBC. HGB < 0 . 5%. PLT < 1 %

Performance
Parameter
WBC ( 10o /L )
                      Linearity range
                         0.0 - 99.9
                                                   Precision (CV%)
                                                   3 . 5 ( 7.0 - 15 . 0 )
                                                                             Input /output
RBC ( 10”/L )            0.00 - 9.99               2 . 0 ( 3. 50 - 6.00 )    1 Rs 232
HGB ( g/L )               0 - 300                  1 . 5 ( 110 - 180 )
MCV ( f L )               40 . 0 - 150. 0          0 . 5 ( 80 . 0 - 110 . 0)
PLT ( 100 /L )            0 - 999                   4 . 0 ( 200 - 500 )      Printout
Throughput                                                             Built - in thermal printer ( 2 optimal print modes )
45 samples per hour


Menu                                                                   Operating Environment
Record review, Test, Maintenance, OC , Shutdown.                       Temperature           15 O C - 30 O C
Prime reagents, System diagnosis, calibration,
Aperturerinse, Soak and rinse.                                         Humidity              30 % - 85 %



Display                                                                Power Requlrement
5 . 1 “ LCD display                                                    AC 100 V - 240 V . 50 / 60 hz

Resolution
320 x 240                                                              Dimention
                                                                       370 mm ( H ) X 275 mm ( W ) X 400 mm ( D )
Sample Volume
Venous blood or capillay 20 ul

                                                                       Weight
Aperture Diameter
WBC          80um                                                      13 . 8 kg
RBC/PLT     80um




                 ReiGed Diagnostics :
                 www.ReiGed-Diagnostics.com
                 janto@reiged-diagnostics.com jantosth@telkom.net

More Related Content

Viewers also liked

Automated cell counter & its quality control
Automated cell counter & its quality controlAutomated cell counter & its quality control
Automated cell counter & its quality controlSaikat Mandal
 
Automation in haematology
Automation in haematologyAutomation in haematology
Automation in haematologyraj kumar
 
Automation in haematology bernard
Automation in haematology   bernardAutomation in haematology   bernard
Automation in haematology bernardBosco Mbonimpa
 
Instrument Calibration
Instrument Calibration Instrument Calibration
Instrument Calibration Ramesh Dham
 

Viewers also liked (6)

Automated cell counter & its quality control
Automated cell counter & its quality controlAutomated cell counter & its quality control
Automated cell counter & its quality control
 
Automation in haematology
Automation in haematologyAutomation in haematology
Automation in haematology
 
Calibration
CalibrationCalibration
Calibration
 
Automation in haematology bernard
Automation in haematology   bernardAutomation in haematology   bernard
Automation in haematology bernard
 
Instrument Calibration
Instrument Calibration Instrument Calibration
Instrument Calibration
 
Sysmex xe-5000
Sysmex xe-5000Sysmex xe-5000
Sysmex xe-5000
 

Similar to Tek Ii Mini

KT-40-20191015.pdf
KT-40-20191015.pdfKT-40-20191015.pdf
KT-40-20191015.pdfmahin71
 
Elisa Brio 2
Elisa Brio 2Elisa Brio 2
Elisa Brio 2gerobag
 
Diagnostic equipments
Diagnostic equipmentsDiagnostic equipments
Diagnostic equipmentsPaul Priyaraj
 
abbott Architect i2000 SR
abbott Architect i2000 SRabbott Architect i2000 SR
abbott Architect i2000 SRmaryphilar02
 
Prime Evolution
Prime EvolutionPrime Evolution
Prime Evolutiongerobag
 
1AccuSimTotalPatientSimulator&DigitalManometer
1AccuSimTotalPatientSimulator&DigitalManometer1AccuSimTotalPatientSimulator&DigitalManometer
1AccuSimTotalPatientSimulator&DigitalManometerJoseph Rebot
 
mindray-umec-15-patient-monitor-lead.pdd
mindray-umec-15-patient-monitor-lead.pddmindray-umec-15-patient-monitor-lead.pdd
mindray-umec-15-patient-monitor-lead.pddlemmabekele2
 
Urine Rd 120 G
Urine Rd 120 GUrine Rd 120 G
Urine Rd 120 Ggerobag
 
Hematology technology
Hematology technologyHematology technology
Hematology technologymanueldsx
 
Sediment Analyzer
Sediment AnalyzerSediment Analyzer
Sediment Analyzergerobag
 
Omicron CMC 256plus High Precision Relay Test Set and Universal Calibrator Da...
Omicron CMC 256plus High Precision Relay Test Set and Universal Calibrator Da...Omicron CMC 256plus High Precision Relay Test Set and Universal Calibrator Da...
Omicron CMC 256plus High Precision Relay Test Set and Universal Calibrator Da...Angus Sankaran
 

Similar to Tek Ii Mini (20)

KT-40-20191015.pdf
KT-40-20191015.pdfKT-40-20191015.pdf
KT-40-20191015.pdf
 
Elisa Brio 2
Elisa Brio 2Elisa Brio 2
Elisa Brio 2
 
Diagnostic equipments
Diagnostic equipmentsDiagnostic equipments
Diagnostic equipments
 
Specification
SpecificationSpecification
Specification
 
abbott Architect i2000 SR
abbott Architect i2000 SRabbott Architect i2000 SR
abbott Architect i2000 SR
 
Abbott.pdf
Abbott.pdfAbbott.pdf
Abbott.pdf
 
Validation and calibration of equipment
Validation and calibration of equipment Validation and calibration of equipment
Validation and calibration of equipment
 
Prime Evolution
Prime EvolutionPrime Evolution
Prime Evolution
 
1AccuSimTotalPatientSimulator&DigitalManometer
1AccuSimTotalPatientSimulator&DigitalManometer1AccuSimTotalPatientSimulator&DigitalManometer
1AccuSimTotalPatientSimulator&DigitalManometer
 
Titrators
TitratorsTitrators
Titrators
 
mindray-umec-15-patient-monitor-lead.pdd
mindray-umec-15-patient-monitor-lead.pddmindray-umec-15-patient-monitor-lead.pdd
mindray-umec-15-patient-monitor-lead.pdd
 
Tecpel catalog
Tecpel catalogTecpel catalog
Tecpel catalog
 
Urine Rd 120 G
Urine Rd 120 GUrine Rd 120 G
Urine Rd 120 G
 
Hematology technology
Hematology technologyHematology technology
Hematology technology
 
cdi_500.pdf
cdi_500.pdfcdi_500.pdf
cdi_500.pdf
 
Chem 5 v3 ver 10
 Chem 5 v3 ver 10 Chem 5 v3 ver 10
Chem 5 v3 ver 10
 
Gas-Chromatography.pdf
Gas-Chromatography.pdfGas-Chromatography.pdf
Gas-Chromatography.pdf
 
Sediment Analyzer
Sediment AnalyzerSediment Analyzer
Sediment Analyzer
 
Omicron CMC 256plus High Precision Relay Test Set and Universal Calibrator Da...
Omicron CMC 256plus High Precision Relay Test Set and Universal Calibrator Da...Omicron CMC 256plus High Precision Relay Test Set and Universal Calibrator Da...
Omicron CMC 256plus High Precision Relay Test Set and Universal Calibrator Da...
 
Hopu transformer oil bdv tester series hjt
Hopu transformer oil bdv tester series hjtHopu transformer oil bdv tester series hjt
Hopu transformer oil bdv tester series hjt
 

More from gerobag

E Card Print per 30 april
E Card Print per 30 aprilE Card Print per 30 april
E Card Print per 30 aprilgerobag
 
Kenari Magazine Edisi 4
Kenari Magazine Edisi 4Kenari Magazine Edisi 4
Kenari Magazine Edisi 4gerobag
 
R E A G E N T
R E A G E N TR E A G E N T
R E A G E N Tgerobag
 
Rd Reader
Rd ReaderRd Reader
Rd Readergerobag
 
Rd Washer
Rd WasherRd Washer
Rd Washergerobag
 
Kuadro Keylab
Kuadro KeylabKuadro Keylab
Kuadro Keylabgerobag
 
Urine H 50
Urine H 50Urine H 50
Urine H 50gerobag
 
Elisa Washer Drop
Elisa Washer DropElisa Washer Drop
Elisa Washer Dropgerobag
 
Elisa Reader Sirio
Elisa Reader SirioElisa Reader Sirio
Elisa Reader Siriogerobag
 

More from gerobag (18)

E Card Print per 30 april
E Card Print per 30 aprilE Card Print per 30 april
E Card Print per 30 april
 
Kenari Magazine Edisi 4
Kenari Magazine Edisi 4Kenari Magazine Edisi 4
Kenari Magazine Edisi 4
 
R E A G E N T
R E A G E N TR E A G E N T
R E A G E N T
 
Rd Coag
Rd CoagRd Coag
Rd Coag
 
Rd 7021
Rd 7021Rd 7021
Rd 7021
 
Rd 140
Rd 140Rd 140
Rd 140
 
Rd 60
Rd 60Rd 60
Rd 60
 
Rd 240
Rd 240Rd 240
Rd 240
 
Rd Lyte
Rd LyteRd Lyte
Rd Lyte
 
Rd Reader
Rd ReaderRd Reader
Rd Reader
 
Rd Washer
Rd WasherRd Washer
Rd Washer
 
Reagent
ReagentReagent
Reagent
 
Slim
SlimSlim
Slim
 
Global
GlobalGlobal
Global
 
Kuadro Keylab
Kuadro KeylabKuadro Keylab
Kuadro Keylab
 
Urine H 50
Urine H 50Urine H 50
Urine H 50
 
Elisa Washer Drop
Elisa Washer DropElisa Washer Drop
Elisa Washer Drop
 
Elisa Reader Sirio
Elisa Reader SirioElisa Reader Sirio
Elisa Reader Sirio
 

Tek Ii Mini

  • 1. ReiGed Diagnostics TEK II MINI Auto Hematology Analyzer Registrasi Depkes RI AKL 20205900471 > 3 - Part differeniation of WBC ; 18 parameters + 3histograms > Double apertures for WBC and RBC / PLT > Throughput : 45samples per hour > Patented aperture technology : Automatic clog-clearing with high pressure and lower rate of clog > Automatic diluting, lyzing,mixing, rinsing and clog-clearing > Automatically cleaning sampling probe > Built - intermal printer > Up to 100 test results with histogram and 1100 samples test results without histogram > LCD with high resolution ReiGed Diagnostics : www.ReiGed-Diagnostics.com janto@reiged-diagnostics.com jantosth@telkom.net
  • 2. ReiGed Diagnostics TEK II MINI Technical Specification Parameters Dilution Ratione WBC, LY#. MO#, GR#, LY%, MO% , GR%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, PLT, MPV, PDW, PCT and Histogram for WBC 1 : 500 WBC, RBC, PLT RBC/PLT 1 : 40000 Method Coulter Principle (Electrical impedance) Carryover Colorimetry haemoglobin determination WBC. RBC. HGB < 0 . 5%. PLT < 1 % Performance Parameter WBC ( 10o /L ) Linearity range 0.0 - 99.9 Precision (CV%) 3 . 5 ( 7.0 - 15 . 0 ) Input /output RBC ( 10”/L ) 0.00 - 9.99 2 . 0 ( 3. 50 - 6.00 ) 1 Rs 232 HGB ( g/L ) 0 - 300 1 . 5 ( 110 - 180 ) MCV ( f L ) 40 . 0 - 150. 0 0 . 5 ( 80 . 0 - 110 . 0) PLT ( 100 /L ) 0 - 999 4 . 0 ( 200 - 500 ) Printout Throughput Built - in thermal printer ( 2 optimal print modes ) 45 samples per hour Menu Operating Environment Record review, Test, Maintenance, OC , Shutdown. Temperature 15 O C - 30 O C Prime reagents, System diagnosis, calibration, Aperturerinse, Soak and rinse. Humidity 30 % - 85 % Display Power Requlrement 5 . 1 “ LCD display AC 100 V - 240 V . 50 / 60 hz Resolution 320 x 240 Dimention 370 mm ( H ) X 275 mm ( W ) X 400 mm ( D ) Sample Volume Venous blood or capillay 20 ul Weight Aperture Diameter WBC 80um 13 . 8 kg RBC/PLT 80um ReiGed Diagnostics : www.ReiGed-Diagnostics.com janto@reiged-diagnostics.com jantosth@telkom.net