SlideShare a Scribd company logo
1 of 6
Download to read offline
Lagoa Series
                                                                                                     Diaphragm dosing pumps                            PCM PRECI POMPE
                                                                                                     Simple, reliable, deliverable

  Applications                                                                                       within 2 to 6 days




Food
• Metering of alkaline and/or acid products and disinfecting solutions
                                                                                                                                     Lagoa Series
  into installed cleaning systems (CIP)
• Metering of fermentation products and renet in the dairy industry                                                                  Diaphragm dosing pumps
• Metering of anti-foaming products
• Metering of flavoring, coloring agents and yeasts                                                                                  Simple, reliable, deliverable within 2 to 6 days
• Metering of citric acid and ascorbic acid
• Metering of sugar syrup
• Metering of arabic gum, sulfur anhydride, casein and gelatine
  as additives in wine-production
• Metering of diatomaceous earth (filtration of brine baths)
• Metering of liquid fertilizer
                                                                            Pump on filtering pallet (wine production)


Industry
• Surface treatment:




                                                                                                                                                                                                                                                                                                                                       Designed & realised by www.altavox.biz - E-TD0053LAG 05-05 — PCM reserves the right to change this data at all times. This document was printed with toxic-free ink.
  - Metering of degreasing agents and surfagents for surface preparation
  - Metering of hydrochloric acid and inhibitor
  - Additions of chromic acid for electrophoresis
  - Additions of sulfuric acide or phosphoric acid to top-up bath levels
  - Metering of wetting agent for coil coating
• Foundries: proportional metering of resin and catalyzer in the
  production of sand moulds
• Paper-making: metering of coloring agents and anti-foaming agents
• Textiles: metering of coloring agents
• Cement: metering of wetting agent, waterproofing agent and
  water-reducing plasticizer in the production of plasterboard
• Tile production: metering of coloring paste
• Timber: metering of fungicide                                                     Metering of soda and acid




Environment
• Metering of coagulants: polymer of viscosity lower than 1500cP
  (polyacrylamides). Injection of diluted polymer into concentrated
  ludges can decrease pressure losses and thereby contribute to                                                                                                                                                                                        HEAD OFFICE
  reducing operating costs
• Metering of coagulants such as ferric chloride, ferric sulfate, ferrous                                                                                                                                          UNITED STATES                         FRANCE                              CHINA
  sulfate, alumina sulfate, aluminum chloride (WAC, PAC)                                                                                                                                                         Tel: +1 713 896 4888                    PCM S.A.                    Tel: +86 (0)21 62362521
• Metering of anti-foaming products                                                                                                                                                                              Fax: +1 713 896 4806            17 rue Ernest Laval - BP 35         Fax: +86 (0)21 62362428
                                                                                                                                                                                                                                                   92173 VANVES Cedex
• Metering of alkaline and acidic products: hydrochloric acid, phosphoric                                                                                                                                     pcmdelasco@pcmdelasco.com                                                 pcmchina@pcm.eu
                                                                                                                                                                                                                                                          FRANCE
  acid, nitric acid and soda                                                                                                                                                                                     www.pcmdelasco.com                                                        www.pcm.eu
                                                                                                                                                                                                                                                 Tél : +33 (0)1 41 08 15 15
• Metering of biocides and disinfectants for preventing the develop-
                                                                                                                                                                                                                                                 Fax : +33 (0)1 41 08 15 00
  ment of bacteria (sodium or calcium hypochlorite, or chorine bioxide)                                                                                                                                                                               contact@pcm.eu
• Metering of hydrazine (elimination of oxygen dissolved in boiler water)                                                                                                                                                                               www.pcm.eu
• Metering of sodium carbonate for re-establishing the calcium/carbon
  balance in water
• Metering of methanol (atex), phosphoric acid and urea as nutrients.                                                                                                                   UNITED KINGDOM                        GERMANY                    TUNISIA                    THAILAND                          RUSSIA
                                                                                                                                                                                        Tel: +44 (0)1536 740200        Tel: +49 (0)611 60977-0     Tel: +216 71 238 138        Tel: +66 (0)34 246 012          Tel: +7(812)320 70 96
                                                                                                                                                                                        Fax: +44 (0)1536 740201       Fax: +49 (0)611 60977-20     Fax: +216 71 231 713        Fax: +66 (0)34 297 022          Fax: +7(812)320 75 12
                                                                                                                                                                                         sales@pcmpumps.co.uk               info@delasco.de         pcmtunisie@pcm.eu            mwitayat@pcm.eu                pcmrussia@pcm.eu
                                                                                                                                                                                          www.pcmpumps.co.uk                www.delasco.de              www.pcm.eu                   www.pcm.eu                     www.pcm.eu
                                                                            Ferric chloride pumping in purification station
P C M Po m p e s                                    The Lagoa series is designed for metering a wide variety                                                                                                                                                                                                                                                                                                                                                                               Lagoa Series
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           Diaphragm dosing pumps
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           Simple, reliable, deliverable
Lagoa series:                                       of products in chemical engineering, environmental                                                                                                                                                                                    Understanding model designation                                                                                                                                                                  within 2 to 6 days
S i m p l i c i t y, r e l i a b i l i t y                                                                                                                    Drive
a n d av a i l a b i l i t y                        applications as well as the food and personal care industries




                                                                                                                                                       ▲
                                                                                                                                                              The pump is driven by a direct mounted light alloy                                                                                                                                                                                                                                           Pumphead type
                                                                                                                                                              motor with IP55 protection. The bearings are greased                                                                                             LG1                      U                    50                   T                                                       U     Polypro
                                                                                                                                                              for life, making the motors maintenance-free.                                                                                                                                                                                                                               H     PVC
     Advantages
▲




                                                                                                                                                                                                                                                                                                                                                                                                                                          S     Stainless steel
                                                                                                                                                                                                                                                                                              Hydraulics size               Pumphead type                     Nominal flow            Drive unit type
                                                                                                                                                                                                                                                                                                                                                                                                                                          SA    Stainless steel with food connections
Of electro-mechanical drive
• Reduced mechanical and hydraulic shocks
• Silent
• Does not cause and is not affected                                                                                                                                              Pumphead                                          Applicable directives and standards                       Performances
  by interference




                                                                                                                                                                             ▲
                                                                                                                                                                                  The pumphead is easy to remove and change.                                                                                                                     Flow at 1 bar - 50Hz                 Flow at Pmax - 50Hz                    Pressure                  Rate                     Power
                                                                                                                                                                                                                                                             (1)                          Model                     Pumpheads                       10 %       100 %                     10 %     100 %                       max**                    50Hz                Mono (M) Three (T)
Of the design
• Simple and robust construction
                                                                                                                                                                                  It consists of:
                                                                                                                                                                                       - 1 suction check valve
                                                                                                                                                                                                                                                                      FDA                                                                            l/h         l/h                      l/h       l/h                         bar                strokes/min                W        W
                                                                                                                                                                                                                                                                                          LG1 - 4                                                     1           4                        0        3,3                         12                      48                  60***      60
• Reliability of metering                                                                                                                                                              - 1 discharge check valve                                                                          LG1 - 20                                                    3         18,5                       1        15                          10                      48                  60***      60
• Adaptable: meters a wide range of fluids                                                                                                                                             - 1 liquid end body                          The pumps in the Lagoa series meet the                LG1 - 50                                                   10          47                        2        42                           5                     120                  60***      60
• Simplified maintenance                                                                                                                                                                                                            machine directive requirements and its
                                                                                                                                                                                  Pumpheads are available in many material                                                                LG2 - 20                  U, H, S, SA                       6          20                       0,5       16                          10                      48                    -       120
                                                                                                                                                                                                                                    harmonized standards.
• Dry running                                                                                                                                                                     combinations as shown in the table on the                                                               LG2 - 50                                                   12          51                        2        45                          10                     120                    -       250

                                                                                                                                                                                  next page.                                       • • • • • • • • • • •                                  LG2 - 140                                                  25         145                       10       127                          7.5                     48                    -       120
                                                                                                                                                                                                                                                                                          LG2 - 350                                                  70         350                       40       330                           5                     120                    -       250
Technical data                                                                                                                                                                    Note: other versions are available on request.                                                          LG2 - 350 duplex *           U, H, S                      140         700                       80       660                           5                     120                    -       250
• Maximum flow: 350l/hr per pumphead                                                                                                                                                                                                                                                  * asynchronous pumpheads - ** maximum pressures are stated at 20°C - *** available with the U pumphead only.
• Adjustable from 10 to 100%                                                                                                                                                                                                        Accessories
• Maximum pressure: 12 bar                                                                                                                                                                                                                                                             Flow rate (Q)             Curves Q / P                                                                   Flow rate (Q)              Curves Q / P
• Maximum temperature: 100°C                                                                                                                                                                                                        PCM offers you a comprehensive range                   in l/h                                                                                                   in l/h
• Speed: 48 and 120 strokes/min                                                                                                                                                                                                     of solutions to enable you to achieve
                                                                                                                                                                                                                                    high-performance metering regardless of                   50                                                                                                 800
• Precision: ± 1%
• Linearity: ± 3%                                                                                                                                                                                                                   the working conditions of your installation.
                                                                                                                                                                                                                                                                                                                                                             LG1 - 50
                                                                                                                                                                                                                                                                                                                                                                                                                                                                 LG2 - 350 duplex
                                                                                                                                                                                                                                                                                              40                                                                                                 600
Deliverable within 2 to 6 days.                                                                                                                                                                                                                       Foot valves
                                                                                                                                                                                                                                                      Filter undesirable
                                                          Locking device                                                                                                                                                                              particles and keep the
                                                      ▲




Operation                                                 The stroke adjustment                                                                                                                                                                       pump primed when
                                                                                                                                                                                                                                                                                              30                                                                                                 400

The Lagoa pump is composed of a membrane                  mechanism can be locked in                                                                                                                                                                  stopped.
                                                                                                                                                                                                                                                                                                                                                                                                                                                                 LG2 - 350

connected to a piston of which the alternating            position to ensure that stroke                                                                                              Diaphragm
movement successively fills and empties the               length remains at its set point.                                                                                                                                                                                                    20                                                                                                 200




                                                                                                                                                                                ▲
                                                                                                                                                                                      Preformed type, made of PTFE reinforced                         Injection rod
pumphead.
                                                                                                                                                                                      with elastomer. The liquid contact part is                      Enables your product                                                                                   LG1 - 20
1 The backward movement of the membrane                                                                                                                                               in chemically inert PTFE.                                                                                                                                                                                                                                                  LG2 - 140
                                                                                                                                                                                                                                                      to be injected in a vein
  opens the bottom check valve and allows the                                                                                                                                                                                                                                                 10                                                                                                 100
  entry of fluid, which fills the pumphead.                                                                                                                                                                                                           without polluting the
                                                                                                                                                                                                                                                      injection pipework                                                                                                                                                                                         LG2 - 50
2 The forward movement of the membrane closes                                                                                                                                                                                                                                                                                                                LG1 - 4
                                                                                                                                                                                                                                                      (non-return function).                                                                                                                                                                                     LG2 - 20
  the bottom check valve, opens the top check                                                                                                                                                                                                                                                                                                                 Pressure (P) in bar                                                                                  Pressure (P) in bar
                                                                                                                                                                                                                                                                                                       1 2 3 4 5 6 7 8 9 10 11 12                                                                             1 2 3 4 5 6 7 8 9 10 11 12
  valve and expels the dose.
                                                                                                                                                                                                                                                      Safety and retention
                                                                                                                                                                                                                                                      valves
                                                                                                                                                                                                                                                      Prevent excess flow and                 Overall Dimensions                                                                               Connections
                                                                                                                                                                                                                                                      pressures, siphoning                                        L          l               A           B       C                                                                                     Pumphead type
                                                                                                                                                                                                                                                                                          Model                                                                                            Pumphead size
                                                                                                                                                                                                                                                      and underloading.                                          mm         mm              mm          mm      mm                                                                U                    H                     S                     SA
                                                                                                                                      Casing                                                                                                                                              LG1 - 4                294        160          65.5       58.5        136                        4
                                                                                                                                                                                                                                                                                                                                                                                                                        4x8 flexible hose
                              1 - Suction phase                                                                                   ▲   Robust cast aluminium                                                                                                                               LG1 - 20               302        160          65.5       58.5        168                                                    or 10-16 PVC pipe                                  1/2"              DIN DN10
                                                                                                                                                                                                                                                      Pulsation dampers                                          302        160          65.5       58.5        168                        20                          6x12 flexible hose                                G male               male
                                                                                                                                      alloy construction.                                                                                                                                 LG1 - 50
                                                                                                                                                                                                                                                      To render your flow                                                                                                                  50                          or 10-16 PVC pipe          1" G male
                                                                                                                                                                                                                                                                                          LG2 - 20               375        210         114.5       58.5        168
                                                                                                                                                                                                                                                                                                                                                                                           140
                                                                                                                                                                                                                                                      linear and lessen                   LG2 - 50               375        210         114.5       58.5        168
                                                                                                                                                                                                                                                                                                                                                                                           350                               1" G male                                    3/4"             SMS 25 male
                                                                                                                                                                                                                                                      fluid hammer effects.               LG2 - 140              429        223          159         59         246                                                                                                     G female
                                                                                                                                                                                                                                                                                                                                                                                           350 duplex                                                                                              —
                                                                                                                                                                                                                                                                                          LG2 - 350              429        223          159         59         246
                                                                                                                                                                                                                                                                                          LG2 - 350 duplex       429        389          159         59         246
                                                                              Stroke adjustment                                                                                                                                                       "Ready-to-meter"
                                                                         ▲




                                                                              The capacity is set by turning the micrometer                                                                                                                           assemblies
                                                                              dial which is fitted with vernier scale graduated                                                                                                                       You connect the assembly
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                             165




                                                                              in percentage stroke length.                                                                                                                                            to the pump and you are
                                                                              Electric servo control can be fitted (1).                                                                                                                               ready to start !
                                                                                                                                                                           Possibility of multiplexing for:




                                                                                                                                                                                                                                                                                                                                                                                                                                                           321
                                                                                                                                                                                                                                                                                                                                                              299




                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   321
                                                                                                                                                                                                                                                                                                                                                                              =
                              2 - Discharge phase




                                                                                                                                                                                                                                                                                          =
                                                                                                                                                                           - performing proportional metering with different




                                                                                                                                                                                                                                                                                                                                                                          C
                                                                                                                                                                                                                                                                                      C
                                                                                                                                                                             fluids (a resin and a hardener, for example)




                                                                                                                                                                                                                                                                                                                                                                                                                      75
                                                                                                                                                                                                                                                      Dosunits (1)




                                                                                                                                                                                                                                                                                          =




                                                                                                                                                                                                                                                                                                                            75




                                                                                                                                                                                                                                                                                                                                                                              =
                                                                                                                                                                           - obtaining a greater flow than with one single                            Complete metering                                                              4                                                                                          4                                         8
                                                                                                                                                                                                                                                                                                                                                                                                                                                                      fixation
                                                                                                                                                                                                                                                                                                   A       148         B                          139
                                                                                                                                                                             pumphead                                                                 units on a 120 to 1000 l                                                   fixation                                                  A            172      B
                                                                                                                                                                                                                                                                                                                                                                                                                            fixation      139                                        139       26       139


                                                                                                                                                                                                                                                                                                           L                       holes          160                                                                         holes                                     holes
                                                                                                                                                                                                                                                                                                                                                                                                                                                                       Ø6mm
                                                                                                                                                                                                                                                                                                                                                                                                  L
                                                                                                                                                                           - phasing the pump stroke to prevent pulsations                            capacity HDPE tank.                                                         Ø6mm                                                                                       Ø6mm
                                                                                                                                                                             and thereby achieving linear flow.                                               (1) Please contact us                                        Lagoa LG1                                                                                 Lagoa LG2                                                     Lagoa LG2 Duplex
P C M Po m p e s                                    The Lagoa series is designed for metering a wide variety                                                                                                                                                                                                                                                                                                                                                                               Lagoa Series
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           Diaphragm dosing pumps
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           Simple, reliable, deliverable
Lagoa series:                                       of products in chemical engineering, environmental                                                                                                                                                                                    Understanding model designation                                                                                                                                                                  within 2 to 6 days
S i m p l i c i t y, r e l i a b i l i t y                                                                                                                    Drive
a n d av a i l a b i l i t y                        applications as well as the food and personal care industries




                                                                                                                                                       ▲
                                                                                                                                                              The pump is driven by a direct mounted light alloy                                                                                                                                                                                                                                           Pumphead type
                                                                                                                                                              motor with IP55 protection. The bearings are greased                                                                                             LG1                      U                    50                   T                                                       U     Polypro
                                                                                                                                                              for life, making the motors maintenance-free.                                                                                                                                                                                                                               H     PVC
     Advantages
▲




                                                                                                                                                                                                                                                                                                                                                                                                                                          S     Stainless steel
                                                                                                                                                                                                                                                                                              Hydraulics size               Pumphead type                     Nominal flow            Drive unit type
                                                                                                                                                                                                                                                                                                                                                                                                                                          SA    Stainless steel with food connections
Of electro-mechanical drive
• Reduced mechanical and hydraulic shocks
• Silent
• Does not cause and is not affected                                                                                                                                              Pumphead                                          Applicable directives and standards                       Performances
  by interference




                                                                                                                                                                             ▲
                                                                                                                                                                                  The pumphead is easy to remove and change.                                                                                                                     Flow at 1 bar - 50Hz                 Flow at Pmax - 50Hz                    Pressure                  Rate                     Power
                                                                                                                                                                                                                                                             (1)                          Model                     Pumpheads                       10 %       100 %                     10 %     100 %                       max**                    50Hz                Mono (M) Three (T)
Of the design
• Simple and robust construction
                                                                                                                                                                                  It consists of:
                                                                                                                                                                                       - 1 suction check valve
                                                                                                                                                                                                                                                                      FDA                                                                            l/h         l/h                      l/h       l/h                         bar                strokes/min                W        W
                                                                                                                                                                                                                                                                                          LG1 - 4                                                     1           4                        0        3,3                         12                      48                  60***      60
• Reliability of metering                                                                                                                                                              - 1 discharge check valve                                                                          LG1 - 20                                                    3         18,5                       1        15                          10                      48                  60***      60
• Adaptable: meters a wide range of fluids                                                                                                                                             - 1 liquid end body                          The pumps in the Lagoa series meet the                LG1 - 50                                                   10          47                        2        42                           5                     120                  60***      60
• Simplified maintenance                                                                                                                                                                                                            machine directive requirements and its
                                                                                                                                                                                  Pumpheads are available in many material                                                                LG2 - 20                  U, H, S, SA                       6          20                       0,5       16                          10                      48                    -       120
                                                                                                                                                                                                                                    harmonized standards.
• Dry running                                                                                                                                                                     combinations as shown in the table on the                                                               LG2 - 50                                                   12          51                        2        45                          10                     120                    -       250

                                                                                                                                                                                  next page.                                       • • • • • • • • • • •                                  LG2 - 140                                                  25         145                       10       127                          7.5                     48                    -       120
                                                                                                                                                                                                                                                                                          LG2 - 350                                                  70         350                       40       330                           5                     120                    -       250
Technical data                                                                                                                                                                    Note: other versions are available on request.                                                          LG2 - 350 duplex *           U, H, S                      140         700                       80       660                           5                     120                    -       250
• Maximum flow: 350l/hr per pumphead                                                                                                                                                                                                                                                  * asynchronous pumpheads - ** maximum pressures are stated at 20°C - *** available with the U pumphead only.
• Adjustable from 10 to 100%                                                                                                                                                                                                        Accessories
• Maximum pressure: 12 bar                                                                                                                                                                                                                                                             Flow rate (Q)             Curves Q / P                                                                   Flow rate (Q)              Curves Q / P
• Maximum temperature: 100°C                                                                                                                                                                                                        PCM offers you a comprehensive range                   in l/h                                                                                                   in l/h
• Speed: 48 and 120 strokes/min                                                                                                                                                                                                     of solutions to enable you to achieve
                                                                                                                                                                                                                                    high-performance metering regardless of                   50                                                                                                 800
• Precision: ± 1%
• Linearity: ± 3%                                                                                                                                                                                                                   the working conditions of your installation.
                                                                                                                                                                                                                                                                                                                                                             LG1 - 50
                                                                                                                                                                                                                                                                                                                                                                                                                                                                 LG2 - 350 duplex
                                                                                                                                                                                                                                                                                              40                                                                                                 600
Deliverable within 2 to 6 days.                                                                                                                                                                                                                       Foot valves
                                                                                                                                                                                                                                                      Filter undesirable
                                                          Locking device                                                                                                                                                                              particles and keep the
                                                      ▲




Operation                                                 The stroke adjustment                                                                                                                                                                       pump primed when
                                                                                                                                                                                                                                                                                              30                                                                                                 400

The Lagoa pump is composed of a membrane                  mechanism can be locked in                                                                                                                                                                  stopped.
                                                                                                                                                                                                                                                                                                                                                                                                                                                                 LG2 - 350

connected to a piston of which the alternating            position to ensure that stroke                                                                                              Diaphragm
movement successively fills and empties the               length remains at its set point.                                                                                                                                                                                                    20                                                                                                 200




                                                                                                                                                                                ▲
                                                                                                                                                                                      Preformed type, made of PTFE reinforced                         Injection rod
pumphead.
                                                                                                                                                                                      with elastomer. The liquid contact part is                      Enables your product                                                                                   LG1 - 20
1 The backward movement of the membrane                                                                                                                                               in chemically inert PTFE.                                                                                                                                                                                                                                                  LG2 - 140
                                                                                                                                                                                                                                                      to be injected in a vein
  opens the bottom check valve and allows the                                                                                                                                                                                                                                                 10                                                                                                 100
  entry of fluid, which fills the pumphead.                                                                                                                                                                                                           without polluting the
                                                                                                                                                                                                                                                      injection pipework                                                                                                                                                                                         LG2 - 50
2 The forward movement of the membrane closes                                                                                                                                                                                                                                                                                                                LG1 - 4
                                                                                                                                                                                                                                                      (non-return function).                                                                                                                                                                                     LG2 - 20
  the bottom check valve, opens the top check                                                                                                                                                                                                                                                                                                                 Pressure (P) in bar                                                                                  Pressure (P) in bar
                                                                                                                                                                                                                                                                                                       1 2 3 4 5 6 7 8 9 10 11 12                                                                             1 2 3 4 5 6 7 8 9 10 11 12
  valve and expels the dose.
                                                                                                                                                                                                                                                      Safety and retention
                                                                                                                                                                                                                                                      valves
                                                                                                                                                                                                                                                      Prevent excess flow and                 Overall Dimensions                                                                               Connections
                                                                                                                                                                                                                                                      pressures, siphoning                                        L          l               A           B       C                                                                                     Pumphead type
                                                                                                                                                                                                                                                                                          Model                                                                                            Pumphead size
                                                                                                                                                                                                                                                      and underloading.                                          mm         mm              mm          mm      mm                                                                U                    H                     S                     SA
                                                                                                                                      Casing                                                                                                                                              LG1 - 4                294        160          65.5       58.5        136                        4
                                                                                                                                                                                                                                                                                                                                                                                                                        4x8 flexible hose
                              1 - Suction phase                                                                                   ▲   Robust cast aluminium                                                                                                                               LG1 - 20               302        160          65.5       58.5        168                                                    or 10-16 PVC pipe                                  1/2"              DIN DN10
                                                                                                                                                                                                                                                      Pulsation dampers                                          302        160          65.5       58.5        168                        20                          6x12 flexible hose                                G male               male
                                                                                                                                      alloy construction.                                                                                                                                 LG1 - 50
                                                                                                                                                                                                                                                      To render your flow                                                                                                                  50                          or 10-16 PVC pipe          1" G male
                                                                                                                                                                                                                                                                                          LG2 - 20               375        210         114.5       58.5        168
                                                                                                                                                                                                                                                                                                                                                                                           140
                                                                                                                                                                                                                                                      linear and lessen                   LG2 - 50               375        210         114.5       58.5        168
                                                                                                                                                                                                                                                                                                                                                                                           350                               1" G male                                    3/4"             SMS 25 male
                                                                                                                                                                                                                                                      fluid hammer effects.               LG2 - 140              429        223          159         59         246                                                                                                     G female
                                                                                                                                                                                                                                                                                                                                                                                           350 duplex                                                                                              —
                                                                                                                                                                                                                                                                                          LG2 - 350              429        223          159         59         246
                                                                                                                                                                                                                                                                                          LG2 - 350 duplex       429        389          159         59         246
                                                                              Stroke adjustment                                                                                                                                                       "Ready-to-meter"
                                                                         ▲




                                                                              The capacity is set by turning the micrometer                                                                                                                           assemblies
                                                                              dial which is fitted with vernier scale graduated                                                                                                                       You connect the assembly
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                             165




                                                                              in percentage stroke length.                                                                                                                                            to the pump and you are
                                                                              Electric servo control can be fitted (1).                                                                                                                               ready to start !
                                                                                                                                                                           Possibility of multiplexing for:




                                                                                                                                                                                                                                                                                                                                                                                                                                                           321
                                                                                                                                                                                                                                                                                                                                                              299




                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   321
                                                                                                                                                                                                                                                                                                                                                                              =
                              2 - Discharge phase




                                                                                                                                                                                                                                                                                          =
                                                                                                                                                                           - performing proportional metering with different




                                                                                                                                                                                                                                                                                                                                                                          C
                                                                                                                                                                                                                                                                                      C
                                                                                                                                                                             fluids (a resin and a hardener, for example)




                                                                                                                                                                                                                                                                                                                                                                                                                      75
                                                                                                                                                                                                                                                      Dosunits (1)




                                                                                                                                                                                                                                                                                          =




                                                                                                                                                                                                                                                                                                                            75




                                                                                                                                                                                                                                                                                                                                                                              =
                                                                                                                                                                           - obtaining a greater flow than with one single                            Complete metering                                                              4                                                                                          4                                         8
                                                                                                                                                                                                                                                                                                                                                                                                                                                                      fixation
                                                                                                                                                                                                                                                                                                   A       148         B                          139
                                                                                                                                                                             pumphead                                                                 units on a 120 to 1000 l                                                   fixation                                                  A            172      B
                                                                                                                                                                                                                                                                                                                                                                                                                            fixation      139                                        139       26       139


                                                                                                                                                                                                                                                                                                           L                       holes          160                                                                         holes                                     holes
                                                                                                                                                                                                                                                                                                                                                                                                                                                                       Ø6mm
                                                                                                                                                                                                                                                                                                                                                                                                  L
                                                                                                                                                                           - phasing the pump stroke to prevent pulsations                            capacity HDPE tank.                                                         Ø6mm                                                                                       Ø6mm
                                                                                                                                                                             and thereby achieving linear flow.                                               (1) Please contact us                                        Lagoa LG1                                                                                 Lagoa LG2                                                     Lagoa LG2 Duplex
Lagoa   series rev.
Lagoa   series rev.
Lagoa   series rev.

More Related Content

Viewers also liked

Laboratory apparatus and safety measures
Laboratory apparatus and safety measuresLaboratory apparatus and safety measures
Laboratory apparatus and safety measuresjulielazarte
 
Solubility (a physical property) (Teach)
Solubility (a physical property)  (Teach)Solubility (a physical property)  (Teach)
Solubility (a physical property) (Teach)Moira Whitehouse
 
Hipertransaminasèmia Assimptomàtica. Javier Aznar.
Hipertransaminasèmia Assimptomàtica. Javier Aznar.Hipertransaminasèmia Assimptomàtica. Javier Aznar.
Hipertransaminasèmia Assimptomàtica. Javier Aznar.DocenciaMontcada
 
Chem m2 laboratory apparatus, safety rules & symbols
Chem m2 laboratory apparatus, safety rules & symbolsChem m2 laboratory apparatus, safety rules & symbols
Chem m2 laboratory apparatus, safety rules & symbolsdionesioable
 
Colligative Properties Of Solutions
Colligative Properties Of SolutionsColligative Properties Of Solutions
Colligative Properties Of Solutionscenglish5
 

Viewers also liked (9)

Laboratory apparatus and safety measures
Laboratory apparatus and safety measuresLaboratory apparatus and safety measures
Laboratory apparatus and safety measures
 
Properties of Solution
Properties of SolutionProperties of Solution
Properties of Solution
 
Solubility (a physical property) (Teach)
Solubility (a physical property)  (Teach)Solubility (a physical property)  (Teach)
Solubility (a physical property) (Teach)
 
Hipertransaminasèmia Assimptomàtica. Javier Aznar.
Hipertransaminasèmia Assimptomàtica. Javier Aznar.Hipertransaminasèmia Assimptomàtica. Javier Aznar.
Hipertransaminasèmia Assimptomàtica. Javier Aznar.
 
Chem m2 laboratory apparatus, safety rules & symbols
Chem m2 laboratory apparatus, safety rules & symbolsChem m2 laboratory apparatus, safety rules & symbols
Chem m2 laboratory apparatus, safety rules & symbols
 
Colligative Properties Of Solutions
Colligative Properties Of SolutionsColligative Properties Of Solutions
Colligative Properties Of Solutions
 
Chemistry!
Chemistry!Chemistry!
Chemistry!
 
PER Equity Initiation Report on AHRO
PER Equity Initiation Report on AHROPER Equity Initiation Report on AHRO
PER Equity Initiation Report on AHRO
 
GOOD LABORATORY PRACTICES
GOOD LABORATORY PRACTICES GOOD LABORATORY PRACTICES
GOOD LABORATORY PRACTICES
 

Similar to Lagoa series rev.

Plumbing Codes
Plumbing CodesPlumbing Codes
Plumbing CodesParkco
 
Weatherford pipeline cleaning services
Weatherford pipeline cleaning servicesWeatherford pipeline cleaning services
Weatherford pipeline cleaning servicesmattgray29
 
Dosing strong acid and caustic soda
Dosing strong acid and caustic sodaDosing strong acid and caustic soda
Dosing strong acid and caustic sodajoostjansma
 
Accent Sales Presentation Ph
Accent Sales Presentation   PhAccent Sales Presentation   Ph
Accent Sales Presentation Phkashivishwanath
 
Recovery of Cyanide From Tailings Using Resins
Recovery of Cyanide From Tailings Using ResinsRecovery of Cyanide From Tailings Using Resins
Recovery of Cyanide From Tailings Using ResinsMidas Engineering Group
 
Nanotech Scope of Technology
Nanotech Scope of TechnologyNanotech Scope of Technology
Nanotech Scope of TechnologyJakes Jacobs
 

Similar to Lagoa series rev. (9)

Z series
Z seriesZ series
Z series
 
Rapid Determination of Inorganic Ions in Wastewater by Ion Chromatography
Rapid Determination of Inorganic Ions in Wastewater by Ion ChromatographyRapid Determination of Inorganic Ions in Wastewater by Ion Chromatography
Rapid Determination of Inorganic Ions in Wastewater by Ion Chromatography
 
Plumbing Codes
Plumbing CodesPlumbing Codes
Plumbing Codes
 
Weatherford pipeline cleaning services
Weatherford pipeline cleaning servicesWeatherford pipeline cleaning services
Weatherford pipeline cleaning services
 
Dosing strong acid and caustic soda
Dosing strong acid and caustic sodaDosing strong acid and caustic soda
Dosing strong acid and caustic soda
 
Accent Sales Presentation Ph
Accent Sales Presentation   PhAccent Sales Presentation   Ph
Accent Sales Presentation Ph
 
Recovery of Cyanide From Tailings Using Resins
Recovery of Cyanide From Tailings Using ResinsRecovery of Cyanide From Tailings Using Resins
Recovery of Cyanide From Tailings Using Resins
 
Nanotech Scope of Technology
Nanotech Scope of TechnologyNanotech Scope of Technology
Nanotech Scope of Technology
 
OCP&E innovative wet scrubber chemicals
OCP&E innovative wet scrubber chemicalsOCP&E innovative wet scrubber chemicals
OCP&E innovative wet scrubber chemicals
 

More from Eko Kiswanto

Af3 instruction manual-cm specialist
Af3 instruction manual-cm specialistAf3 instruction manual-cm specialist
Af3 instruction manual-cm specialistEko Kiswanto
 
Mesin Diesel Toyota tipe 2 KD FTV 14
Mesin Diesel Toyota tipe  2 KD FTV 14Mesin Diesel Toyota tipe  2 KD FTV 14
Mesin Diesel Toyota tipe 2 KD FTV 14Eko Kiswanto
 
Kijang Innova-bensin-vvt-i 1 TR FE
Kijang Innova-bensin-vvt-i 1 TR FEKijang Innova-bensin-vvt-i 1 TR FE
Kijang Innova-bensin-vvt-i 1 TR FEEko Kiswanto
 
Pengukuran listrik
Pengukuran listrikPengukuran listrik
Pengukuran listrikEko Kiswanto
 
Teknisi k3 listrik
Teknisi k3 listrik Teknisi k3 listrik
Teknisi k3 listrik Eko Kiswanto
 
Material science & eng 2014
Material science  & eng 2014Material science  & eng 2014
Material science & eng 2014Eko Kiswanto
 
Agya ayla part number catalog
Agya ayla part number catalogAgya ayla part number catalog
Agya ayla part number catalogEko Kiswanto
 
Avanza xenia part number catalog
Avanza xenia part number catalogAvanza xenia part number catalog
Avanza xenia part number catalogEko Kiswanto
 
Rush terios part number catalog
Rush terios part number catalogRush terios part number catalog
Rush terios part number catalogEko Kiswanto
 
Material science & eng 2011
Material science  & eng 2011Material science  & eng 2011
Material science & eng 2011Eko Kiswanto
 
Material science & eng 2012
Material science  & eng 2012Material science  & eng 2012
Material science & eng 2012Eko Kiswanto
 
Ulsab final report
Ulsab final reportUlsab final report
Ulsab final reportEko Kiswanto
 
Ulsab engineer report complete
Ulsab engineer report completeUlsab engineer report complete
Ulsab engineer report completeEko Kiswanto
 
Wika pressure & temperature handbook
Wika pressure & temperature handbookWika pressure & temperature handbook
Wika pressure & temperature handbookEko Kiswanto
 
Faw whizol cp preview s
Faw whizol cp preview sFaw whizol cp preview s
Faw whizol cp preview sEko Kiswanto
 
Fa whizol poster_a2
Fa whizol poster_a2Fa whizol poster_a2
Fa whizol poster_a2Eko Kiswanto
 
Whizol flyer quick
Whizol flyer quickWhizol flyer quick
Whizol flyer quickEko Kiswanto
 
Whizol product cat 03 14
Whizol product cat 03 14Whizol product cat 03 14
Whizol product cat 03 14Eko Kiswanto
 
7 langkah selamat dari gempa bumi di rumah
7 langkah selamat dari gempa bumi di rumah7 langkah selamat dari gempa bumi di rumah
7 langkah selamat dari gempa bumi di rumahEko Kiswanto
 

More from Eko Kiswanto (20)

Af3 instruction manual-cm specialist
Af3 instruction manual-cm specialistAf3 instruction manual-cm specialist
Af3 instruction manual-cm specialist
 
Mesin Diesel Toyota tipe 2 KD FTV 14
Mesin Diesel Toyota tipe  2 KD FTV 14Mesin Diesel Toyota tipe  2 KD FTV 14
Mesin Diesel Toyota tipe 2 KD FTV 14
 
Kijang Innova-bensin-vvt-i 1 TR FE
Kijang Innova-bensin-vvt-i 1 TR FEKijang Innova-bensin-vvt-i 1 TR FE
Kijang Innova-bensin-vvt-i 1 TR FE
 
Pengukuran listrik
Pengukuran listrikPengukuran listrik
Pengukuran listrik
 
Teknisi k3 listrik
Teknisi k3 listrik Teknisi k3 listrik
Teknisi k3 listrik
 
Material science & eng 2014
Material science  & eng 2014Material science  & eng 2014
Material science & eng 2014
 
Agya ayla part number catalog
Agya ayla part number catalogAgya ayla part number catalog
Agya ayla part number catalog
 
Avanza xenia part number catalog
Avanza xenia part number catalogAvanza xenia part number catalog
Avanza xenia part number catalog
 
Rush terios part number catalog
Rush terios part number catalogRush terios part number catalog
Rush terios part number catalog
 
Material science & eng 2011
Material science  & eng 2011Material science  & eng 2011
Material science & eng 2011
 
Material science & eng 2012
Material science  & eng 2012Material science  & eng 2012
Material science & eng 2012
 
Ulsab final report
Ulsab final reportUlsab final report
Ulsab final report
 
Ulsab engineer report complete
Ulsab engineer report completeUlsab engineer report complete
Ulsab engineer report complete
 
Wika pressure & temperature handbook
Wika pressure & temperature handbookWika pressure & temperature handbook
Wika pressure & temperature handbook
 
Faw whizol cp preview s
Faw whizol cp preview sFaw whizol cp preview s
Faw whizol cp preview s
 
Fa whizol poster_a2
Fa whizol poster_a2Fa whizol poster_a2
Fa whizol poster_a2
 
Whizol flyer quick
Whizol flyer quickWhizol flyer quick
Whizol flyer quick
 
Whizol product cat 03 14
Whizol product cat 03 14Whizol product cat 03 14
Whizol product cat 03 14
 
Geomagz201409
Geomagz201409Geomagz201409
Geomagz201409
 
7 langkah selamat dari gempa bumi di rumah
7 langkah selamat dari gempa bumi di rumah7 langkah selamat dari gempa bumi di rumah
7 langkah selamat dari gempa bumi di rumah
 

Recently uploaded

Marketing Management Business Plan_My Sweet Creations
Marketing Management Business Plan_My Sweet CreationsMarketing Management Business Plan_My Sweet Creations
Marketing Management Business Plan_My Sweet Creationsnakalysalcedo61
 
Catalogue ONG NƯỚC uPVC - HDPE DE NHAT.pdf
Catalogue ONG NƯỚC uPVC - HDPE DE NHAT.pdfCatalogue ONG NƯỚC uPVC - HDPE DE NHAT.pdf
Catalogue ONG NƯỚC uPVC - HDPE DE NHAT.pdfOrient Homes
 
A.I. Bot Summit 3 Opening Keynote - Perry Belcher
A.I. Bot Summit 3 Opening Keynote - Perry BelcherA.I. Bot Summit 3 Opening Keynote - Perry Belcher
A.I. Bot Summit 3 Opening Keynote - Perry BelcherPerry Belcher
 
The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024christinemoorman
 
Intro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfIntro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfpollardmorgan
 
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...lizamodels9
 
VIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service Jamshedpur
VIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service JamshedpurVIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service Jamshedpur
VIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service JamshedpurSuhani Kapoor
 
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...lizamodels9
 
Cash Payment 9602870969 Escort Service in Udaipur Call Girls
Cash Payment 9602870969 Escort Service in Udaipur Call GirlsCash Payment 9602870969 Escort Service in Udaipur Call Girls
Cash Payment 9602870969 Escort Service in Udaipur Call GirlsApsara Of India
 
rishikeshgirls.in- Rishikesh call girl.pdf
rishikeshgirls.in- Rishikesh call girl.pdfrishikeshgirls.in- Rishikesh call girl.pdf
rishikeshgirls.in- Rishikesh call girl.pdfmuskan1121w
 
FULL ENJOY - 9953040155 Call Girls in Chhatarpur | Delhi
FULL ENJOY - 9953040155 Call Girls in Chhatarpur | DelhiFULL ENJOY - 9953040155 Call Girls in Chhatarpur | Delhi
FULL ENJOY - 9953040155 Call Girls in Chhatarpur | DelhiMalviyaNagarCallGirl
 
Sales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for SuccessSales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for SuccessAggregage
 
Investment analysis and portfolio management
Investment analysis and portfolio managementInvestment analysis and portfolio management
Investment analysis and portfolio managementJunaidKhan750825
 
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...lizamodels9
 
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130  Available With RoomVIP Kolkata Call Girl Howrah 👉 8250192130  Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Roomdivyansh0kumar0
 
BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,noida100girls
 
Call Girls in Mehrauli Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Mehrauli Delhi 💯Call Us 🔝8264348440🔝Call Girls in Mehrauli Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Mehrauli Delhi 💯Call Us 🔝8264348440🔝soniya singh
 
Pitch Deck Teardown: NOQX's $200k Pre-seed deck
Pitch Deck Teardown: NOQX's $200k Pre-seed deckPitch Deck Teardown: NOQX's $200k Pre-seed deck
Pitch Deck Teardown: NOQX's $200k Pre-seed deckHajeJanKamps
 

Recently uploaded (20)

Marketing Management Business Plan_My Sweet Creations
Marketing Management Business Plan_My Sweet CreationsMarketing Management Business Plan_My Sweet Creations
Marketing Management Business Plan_My Sweet Creations
 
Catalogue ONG NƯỚC uPVC - HDPE DE NHAT.pdf
Catalogue ONG NƯỚC uPVC - HDPE DE NHAT.pdfCatalogue ONG NƯỚC uPVC - HDPE DE NHAT.pdf
Catalogue ONG NƯỚC uPVC - HDPE DE NHAT.pdf
 
A.I. Bot Summit 3 Opening Keynote - Perry Belcher
A.I. Bot Summit 3 Opening Keynote - Perry BelcherA.I. Bot Summit 3 Opening Keynote - Perry Belcher
A.I. Bot Summit 3 Opening Keynote - Perry Belcher
 
The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024
 
Intro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdfIntro to BCG's Carbon Emissions Benchmark_vF.pdf
Intro to BCG's Carbon Emissions Benchmark_vF.pdf
 
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
 
VIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service Jamshedpur
VIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service JamshedpurVIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service Jamshedpur
VIP Call Girl Jamshedpur Aashi 8250192130 Independent Escort Service Jamshedpur
 
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
 
Cash Payment 9602870969 Escort Service in Udaipur Call Girls
Cash Payment 9602870969 Escort Service in Udaipur Call GirlsCash Payment 9602870969 Escort Service in Udaipur Call Girls
Cash Payment 9602870969 Escort Service in Udaipur Call Girls
 
KestrelPro Flyer Japan IT Week 2024 (English)
KestrelPro Flyer Japan IT Week 2024 (English)KestrelPro Flyer Japan IT Week 2024 (English)
KestrelPro Flyer Japan IT Week 2024 (English)
 
rishikeshgirls.in- Rishikesh call girl.pdf
rishikeshgirls.in- Rishikesh call girl.pdfrishikeshgirls.in- Rishikesh call girl.pdf
rishikeshgirls.in- Rishikesh call girl.pdf
 
FULL ENJOY - 9953040155 Call Girls in Chhatarpur | Delhi
FULL ENJOY - 9953040155 Call Girls in Chhatarpur | DelhiFULL ENJOY - 9953040155 Call Girls in Chhatarpur | Delhi
FULL ENJOY - 9953040155 Call Girls in Chhatarpur | Delhi
 
Enjoy ➥8448380779▻ Call Girls In Sector 18 Noida Escorts Delhi NCR
Enjoy ➥8448380779▻ Call Girls In Sector 18 Noida Escorts Delhi NCREnjoy ➥8448380779▻ Call Girls In Sector 18 Noida Escorts Delhi NCR
Enjoy ➥8448380779▻ Call Girls In Sector 18 Noida Escorts Delhi NCR
 
Sales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for SuccessSales & Marketing Alignment: How to Synergize for Success
Sales & Marketing Alignment: How to Synergize for Success
 
Investment analysis and portfolio management
Investment analysis and portfolio managementInvestment analysis and portfolio management
Investment analysis and portfolio management
 
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
 
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130  Available With RoomVIP Kolkata Call Girl Howrah 👉 8250192130  Available With Room
VIP Kolkata Call Girl Howrah 👉 8250192130 Available With Room
 
BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
BEST Call Girls In Greater Noida ✨ 9773824855 ✨ Escorts Service In Delhi Ncr,
 
Call Girls in Mehrauli Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Mehrauli Delhi 💯Call Us 🔝8264348440🔝Call Girls in Mehrauli Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Mehrauli Delhi 💯Call Us 🔝8264348440🔝
 
Pitch Deck Teardown: NOQX's $200k Pre-seed deck
Pitch Deck Teardown: NOQX's $200k Pre-seed deckPitch Deck Teardown: NOQX's $200k Pre-seed deck
Pitch Deck Teardown: NOQX's $200k Pre-seed deck
 

Lagoa series rev.

  • 1. Lagoa Series Diaphragm dosing pumps PCM PRECI POMPE Simple, reliable, deliverable Applications within 2 to 6 days Food • Metering of alkaline and/or acid products and disinfecting solutions Lagoa Series into installed cleaning systems (CIP) • Metering of fermentation products and renet in the dairy industry Diaphragm dosing pumps • Metering of anti-foaming products • Metering of flavoring, coloring agents and yeasts Simple, reliable, deliverable within 2 to 6 days • Metering of citric acid and ascorbic acid • Metering of sugar syrup • Metering of arabic gum, sulfur anhydride, casein and gelatine as additives in wine-production • Metering of diatomaceous earth (filtration of brine baths) • Metering of liquid fertilizer Pump on filtering pallet (wine production) Industry • Surface treatment: Designed & realised by www.altavox.biz - E-TD0053LAG 05-05 — PCM reserves the right to change this data at all times. This document was printed with toxic-free ink. - Metering of degreasing agents and surfagents for surface preparation - Metering of hydrochloric acid and inhibitor - Additions of chromic acid for electrophoresis - Additions of sulfuric acide or phosphoric acid to top-up bath levels - Metering of wetting agent for coil coating • Foundries: proportional metering of resin and catalyzer in the production of sand moulds • Paper-making: metering of coloring agents and anti-foaming agents • Textiles: metering of coloring agents • Cement: metering of wetting agent, waterproofing agent and water-reducing plasticizer in the production of plasterboard • Tile production: metering of coloring paste • Timber: metering of fungicide Metering of soda and acid Environment • Metering of coagulants: polymer of viscosity lower than 1500cP (polyacrylamides). Injection of diluted polymer into concentrated ludges can decrease pressure losses and thereby contribute to HEAD OFFICE reducing operating costs • Metering of coagulants such as ferric chloride, ferric sulfate, ferrous UNITED STATES FRANCE CHINA sulfate, alumina sulfate, aluminum chloride (WAC, PAC) Tel: +1 713 896 4888 PCM S.A. Tel: +86 (0)21 62362521 • Metering of anti-foaming products Fax: +1 713 896 4806 17 rue Ernest Laval - BP 35 Fax: +86 (0)21 62362428 92173 VANVES Cedex • Metering of alkaline and acidic products: hydrochloric acid, phosphoric pcmdelasco@pcmdelasco.com pcmchina@pcm.eu FRANCE acid, nitric acid and soda www.pcmdelasco.com www.pcm.eu Tél : +33 (0)1 41 08 15 15 • Metering of biocides and disinfectants for preventing the develop- Fax : +33 (0)1 41 08 15 00 ment of bacteria (sodium or calcium hypochlorite, or chorine bioxide) contact@pcm.eu • Metering of hydrazine (elimination of oxygen dissolved in boiler water) www.pcm.eu • Metering of sodium carbonate for re-establishing the calcium/carbon balance in water • Metering of methanol (atex), phosphoric acid and urea as nutrients. UNITED KINGDOM GERMANY TUNISIA THAILAND RUSSIA Tel: +44 (0)1536 740200 Tel: +49 (0)611 60977-0 Tel: +216 71 238 138 Tel: +66 (0)34 246 012 Tel: +7(812)320 70 96 Fax: +44 (0)1536 740201 Fax: +49 (0)611 60977-20 Fax: +216 71 231 713 Fax: +66 (0)34 297 022 Fax: +7(812)320 75 12 sales@pcmpumps.co.uk info@delasco.de pcmtunisie@pcm.eu mwitayat@pcm.eu pcmrussia@pcm.eu www.pcmpumps.co.uk www.delasco.de www.pcm.eu www.pcm.eu www.pcm.eu Ferric chloride pumping in purification station
  • 2. P C M Po m p e s The Lagoa series is designed for metering a wide variety Lagoa Series Diaphragm dosing pumps Simple, reliable, deliverable Lagoa series: of products in chemical engineering, environmental Understanding model designation within 2 to 6 days S i m p l i c i t y, r e l i a b i l i t y Drive a n d av a i l a b i l i t y applications as well as the food and personal care industries ▲ The pump is driven by a direct mounted light alloy Pumphead type motor with IP55 protection. The bearings are greased LG1 U 50 T U Polypro for life, making the motors maintenance-free. H PVC Advantages ▲ S Stainless steel Hydraulics size Pumphead type Nominal flow Drive unit type SA Stainless steel with food connections Of electro-mechanical drive • Reduced mechanical and hydraulic shocks • Silent • Does not cause and is not affected Pumphead Applicable directives and standards Performances by interference ▲ The pumphead is easy to remove and change. Flow at 1 bar - 50Hz Flow at Pmax - 50Hz Pressure Rate Power (1) Model Pumpheads 10 % 100 % 10 % 100 % max** 50Hz Mono (M) Three (T) Of the design • Simple and robust construction It consists of: - 1 suction check valve FDA l/h l/h l/h l/h bar strokes/min W W LG1 - 4 1 4 0 3,3 12 48 60*** 60 • Reliability of metering - 1 discharge check valve LG1 - 20 3 18,5 1 15 10 48 60*** 60 • Adaptable: meters a wide range of fluids - 1 liquid end body The pumps in the Lagoa series meet the LG1 - 50 10 47 2 42 5 120 60*** 60 • Simplified maintenance machine directive requirements and its Pumpheads are available in many material LG2 - 20 U, H, S, SA 6 20 0,5 16 10 48 - 120 harmonized standards. • Dry running combinations as shown in the table on the LG2 - 50 12 51 2 45 10 120 - 250 next page. • • • • • • • • • • • LG2 - 140 25 145 10 127 7.5 48 - 120 LG2 - 350 70 350 40 330 5 120 - 250 Technical data Note: other versions are available on request. LG2 - 350 duplex * U, H, S 140 700 80 660 5 120 - 250 • Maximum flow: 350l/hr per pumphead * asynchronous pumpheads - ** maximum pressures are stated at 20°C - *** available with the U pumphead only. • Adjustable from 10 to 100% Accessories • Maximum pressure: 12 bar Flow rate (Q) Curves Q / P Flow rate (Q) Curves Q / P • Maximum temperature: 100°C PCM offers you a comprehensive range in l/h in l/h • Speed: 48 and 120 strokes/min of solutions to enable you to achieve high-performance metering regardless of 50 800 • Precision: ± 1% • Linearity: ± 3% the working conditions of your installation. LG1 - 50 LG2 - 350 duplex 40 600 Deliverable within 2 to 6 days. Foot valves Filter undesirable Locking device particles and keep the ▲ Operation The stroke adjustment pump primed when 30 400 The Lagoa pump is composed of a membrane mechanism can be locked in stopped. LG2 - 350 connected to a piston of which the alternating position to ensure that stroke Diaphragm movement successively fills and empties the length remains at its set point. 20 200 ▲ Preformed type, made of PTFE reinforced Injection rod pumphead. with elastomer. The liquid contact part is Enables your product LG1 - 20 1 The backward movement of the membrane in chemically inert PTFE. LG2 - 140 to be injected in a vein opens the bottom check valve and allows the 10 100 entry of fluid, which fills the pumphead. without polluting the injection pipework LG2 - 50 2 The forward movement of the membrane closes LG1 - 4 (non-return function). LG2 - 20 the bottom check valve, opens the top check Pressure (P) in bar Pressure (P) in bar 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 valve and expels the dose. Safety and retention valves Prevent excess flow and Overall Dimensions Connections pressures, siphoning L l A B C Pumphead type Model Pumphead size and underloading. mm mm mm mm mm U H S SA Casing LG1 - 4 294 160 65.5 58.5 136 4 4x8 flexible hose 1 - Suction phase ▲ Robust cast aluminium LG1 - 20 302 160 65.5 58.5 168 or 10-16 PVC pipe 1/2" DIN DN10 Pulsation dampers 302 160 65.5 58.5 168 20 6x12 flexible hose G male male alloy construction. LG1 - 50 To render your flow 50 or 10-16 PVC pipe 1" G male LG2 - 20 375 210 114.5 58.5 168 140 linear and lessen LG2 - 50 375 210 114.5 58.5 168 350 1" G male 3/4" SMS 25 male fluid hammer effects. LG2 - 140 429 223 159 59 246 G female 350 duplex — LG2 - 350 429 223 159 59 246 LG2 - 350 duplex 429 389 159 59 246 Stroke adjustment "Ready-to-meter" ▲ The capacity is set by turning the micrometer assemblies dial which is fitted with vernier scale graduated You connect the assembly 165 in percentage stroke length. to the pump and you are Electric servo control can be fitted (1). ready to start ! Possibility of multiplexing for: 321 299 321 = 2 - Discharge phase = - performing proportional metering with different C C fluids (a resin and a hardener, for example) 75 Dosunits (1) = 75 = - obtaining a greater flow than with one single Complete metering 4 4 8 fixation A 148 B 139 pumphead units on a 120 to 1000 l fixation A 172 B fixation 139 139 26 139 L holes 160 holes holes Ø6mm L - phasing the pump stroke to prevent pulsations capacity HDPE tank. Ø6mm Ø6mm and thereby achieving linear flow. (1) Please contact us Lagoa LG1 Lagoa LG2 Lagoa LG2 Duplex
  • 3. P C M Po m p e s The Lagoa series is designed for metering a wide variety Lagoa Series Diaphragm dosing pumps Simple, reliable, deliverable Lagoa series: of products in chemical engineering, environmental Understanding model designation within 2 to 6 days S i m p l i c i t y, r e l i a b i l i t y Drive a n d av a i l a b i l i t y applications as well as the food and personal care industries ▲ The pump is driven by a direct mounted light alloy Pumphead type motor with IP55 protection. The bearings are greased LG1 U 50 T U Polypro for life, making the motors maintenance-free. H PVC Advantages ▲ S Stainless steel Hydraulics size Pumphead type Nominal flow Drive unit type SA Stainless steel with food connections Of electro-mechanical drive • Reduced mechanical and hydraulic shocks • Silent • Does not cause and is not affected Pumphead Applicable directives and standards Performances by interference ▲ The pumphead is easy to remove and change. Flow at 1 bar - 50Hz Flow at Pmax - 50Hz Pressure Rate Power (1) Model Pumpheads 10 % 100 % 10 % 100 % max** 50Hz Mono (M) Three (T) Of the design • Simple and robust construction It consists of: - 1 suction check valve FDA l/h l/h l/h l/h bar strokes/min W W LG1 - 4 1 4 0 3,3 12 48 60*** 60 • Reliability of metering - 1 discharge check valve LG1 - 20 3 18,5 1 15 10 48 60*** 60 • Adaptable: meters a wide range of fluids - 1 liquid end body The pumps in the Lagoa series meet the LG1 - 50 10 47 2 42 5 120 60*** 60 • Simplified maintenance machine directive requirements and its Pumpheads are available in many material LG2 - 20 U, H, S, SA 6 20 0,5 16 10 48 - 120 harmonized standards. • Dry running combinations as shown in the table on the LG2 - 50 12 51 2 45 10 120 - 250 next page. • • • • • • • • • • • LG2 - 140 25 145 10 127 7.5 48 - 120 LG2 - 350 70 350 40 330 5 120 - 250 Technical data Note: other versions are available on request. LG2 - 350 duplex * U, H, S 140 700 80 660 5 120 - 250 • Maximum flow: 350l/hr per pumphead * asynchronous pumpheads - ** maximum pressures are stated at 20°C - *** available with the U pumphead only. • Adjustable from 10 to 100% Accessories • Maximum pressure: 12 bar Flow rate (Q) Curves Q / P Flow rate (Q) Curves Q / P • Maximum temperature: 100°C PCM offers you a comprehensive range in l/h in l/h • Speed: 48 and 120 strokes/min of solutions to enable you to achieve high-performance metering regardless of 50 800 • Precision: ± 1% • Linearity: ± 3% the working conditions of your installation. LG1 - 50 LG2 - 350 duplex 40 600 Deliverable within 2 to 6 days. Foot valves Filter undesirable Locking device particles and keep the ▲ Operation The stroke adjustment pump primed when 30 400 The Lagoa pump is composed of a membrane mechanism can be locked in stopped. LG2 - 350 connected to a piston of which the alternating position to ensure that stroke Diaphragm movement successively fills and empties the length remains at its set point. 20 200 ▲ Preformed type, made of PTFE reinforced Injection rod pumphead. with elastomer. The liquid contact part is Enables your product LG1 - 20 1 The backward movement of the membrane in chemically inert PTFE. LG2 - 140 to be injected in a vein opens the bottom check valve and allows the 10 100 entry of fluid, which fills the pumphead. without polluting the injection pipework LG2 - 50 2 The forward movement of the membrane closes LG1 - 4 (non-return function). LG2 - 20 the bottom check valve, opens the top check Pressure (P) in bar Pressure (P) in bar 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 valve and expels the dose. Safety and retention valves Prevent excess flow and Overall Dimensions Connections pressures, siphoning L l A B C Pumphead type Model Pumphead size and underloading. mm mm mm mm mm U H S SA Casing LG1 - 4 294 160 65.5 58.5 136 4 4x8 flexible hose 1 - Suction phase ▲ Robust cast aluminium LG1 - 20 302 160 65.5 58.5 168 or 10-16 PVC pipe 1/2" DIN DN10 Pulsation dampers 302 160 65.5 58.5 168 20 6x12 flexible hose G male male alloy construction. LG1 - 50 To render your flow 50 or 10-16 PVC pipe 1" G male LG2 - 20 375 210 114.5 58.5 168 140 linear and lessen LG2 - 50 375 210 114.5 58.5 168 350 1" G male 3/4" SMS 25 male fluid hammer effects. LG2 - 140 429 223 159 59 246 G female 350 duplex — LG2 - 350 429 223 159 59 246 LG2 - 350 duplex 429 389 159 59 246 Stroke adjustment "Ready-to-meter" ▲ The capacity is set by turning the micrometer assemblies dial which is fitted with vernier scale graduated You connect the assembly 165 in percentage stroke length. to the pump and you are Electric servo control can be fitted (1). ready to start ! Possibility of multiplexing for: 321 299 321 = 2 - Discharge phase = - performing proportional metering with different C C fluids (a resin and a hardener, for example) 75 Dosunits (1) = 75 = - obtaining a greater flow than with one single Complete metering 4 4 8 fixation A 148 B 139 pumphead units on a 120 to 1000 l fixation A 172 B fixation 139 139 26 139 L holes 160 holes holes Ø6mm L - phasing the pump stroke to prevent pulsations capacity HDPE tank. Ø6mm Ø6mm and thereby achieving linear flow. (1) Please contact us Lagoa LG1 Lagoa LG2 Lagoa LG2 Duplex