Organic Name Reactions for the students and aspirants of Chemistry12th.pptx
Folk House Bonner - For Wet Areas.pdf
1. LAUNDRY STORAGE
01
02
03
04
05
06
07
08
09
10
11 UP
GARAGE
WORKSHOP AREA
RUMPUS ROOM
GUEST BED
BATH
LARDER
SUB FLOOR SPACE
BEDROOM 03
NO STEP
(2400MM HIGH CEILING)
FFL: 672.250
FFL: 672.250
WASHING
MACHINE
DW
UNDER
FW
CONCRETE
BI-FOLD DOORS
BI-FOLD DOORS
5360 8820 9310 2270
7680 160 6180
110
2110 110 6980
160
2270
6280
5820
160
6260
110
1250
110
4050
160
7680 15810 2270
7680
160
2470
110
3000
110
4120 600
110
2090
160
2270
1500
10610
1500
160
6120
110
4050
160
110
700 2070
01
A202
01
A201
02
A201
02
A202
25760
12110
5360 8820 4800 3610 1500 1670
12110
160
900
440
160
4510
2030
2420
1210
160
160
620
4810
760
5690
25760
1150 900 980 2410 1260 2410 1710 1810 3780 1670
5690
SIP PANEL RETAINING WALL
SYSTEM TO ENGINEERS DETAIL.
PROVIDE WATERPROOFING AND
DRAINAGE.
70
ALL CONCRETE SLABS AND FOOTINGS SHALL BE DETERMINED BY SITE CLASSIFICATION AND AS2870
PROVIDE TERMITE PROTECTION IN ACCORDANCE WITH AS3660
ALL TIMBER FRAMING AND CONSTRUCTION MUST COMPLY WITH THE CURRENT VERSION OF THE TIMBER
FRAMING CODE AS1684 AND THE BCA
ALL EXTERNAL WALLS TO BE RENDERED AND PAINTED SIP PANELS UNLESS NOTED OTHERWISE ON THE
DRAWINGS. INSTALL TO MANUFACTURERS SPECIFICATIONS. REFER TO ELEVATIONS FOR LOCATION OF OTHER
EXTERNAL FINISHES INCLUDING METAL AND TIMBER CLADDING.
ALL INSULATION TO COMPLY WITH ENERGY RATING REPORT.
NOTES
PROVIDE SMOKE ALARMS IN ACCORDANCE WITH PART 3.7.2 OF THE BCA AND AS3786.WIRING TO AS3000
WINDOWS TO COMPLY WITH ENERGY RATING REQUIREMENTS AND TO COMPLY WITH ALL RELEVANT
WINDOW CODES AND STANDARDS.
ALL BUSHFIRE RATED CONSTRUCTION AND FIRE RATED SEPARATION MUST BE UNDERTAKEN IN
ACCORDANCE WITH THE BUILDING CODE OF AUSTRALIA AND ALL RELEVENT AUSTRALIAN STANDARDS.
ALL FIRE RATING CONSTRUCTION MUST BE CERTIFIED BY A QUALIFIED PROFESSIONAL.
01
A301
AW1224 AW1224 AW1218
SD2124FS
SD2145FSSF
AW0636
01
A302
NOTE: ALL INTERNAL DOORS TO BE 2400MM HIGH
REFER TO WINDOW SCHEDULE FOR ALL WINDOW SIZES.
WINDOW SUPPLIER TO PROVIDE WINDOW SCHEDULE BY
FOR APPROVAL OF CLIENT PRIOR TO MANUFACTURE.
W01
W02
W03
W04
W05
W06
ALUMINIUM FRAMED
GLASS DOOR
ALUMINIUM FRAMED
GLASS DOOR
OVEN
&
COOKTOP
FRIDGE
CUPD
D01
D02
7680
70
100
Description
Rev drawn Date
Drawing Title
Drawing Number Rev
Date
Project Director
Project Architect Coord.
Reviewed
Verified
Approved
North
Scale Drawn
FLOOR PLAN
LOWER LEVEL
1:100(A3) A101
.
AL&CH
AL&CH
D
26.10.21
Project
BLOCK 1 SECTION 146 BONNER -
Client
JAMES AND ALISON FOLK
All dimensions are in millimetres. All levels are in metres.
Do not scale off drawing. All structure to engineers specification.
All dimensions, levels and site conditions must be verified
by contractor prior to commencement of any work.
All work must be carried out in accordance with the current edition
of the Building Code of Australia & all relevant Australian Standards.
C copyright: heyward lance architecture pty ltd
Reproduction of this design and/or document in whole or in part
without prior written consent is an infringement of copyright.
heyward lance architecture
147 amy ackman st : forde ACT 2914 p : 02 6255 4454
NOTES
COPYRIGHT
ISSUE FOR INFORMATION
P5 AL&CH 11.12.20
ISSUE FOR INFORMATION
P6 AL&CH 21.12.20
1N APPLICATION
P7 AL&CH 15.02.21
PROJECT NO: 2030
ISSUE FOR INFORMATION
A AL&CH 22.04.21
ISSUE FOR INFORMATION
B AL&CH 28.04.21
ISSUE FOR INFORMATION
C AL&CH 15.06.21
ISSUE FOR INFORMATION
D AL&CH 26.10.21
2. 17
18
19
05
06
07
08
R
A
K
E
D
C
E
I
L
I
N
G
WIR
CS
09
10
11
DINING
FAMILY
BEDROOM 02
BEDROOM 01
WIP
ENSUITE
KITCHEN
ENSUITE
WC
ALLOW
TO
SITE
MEASURE
STACKING
SLIDER
DOORS
12
13
14
15
16
HIGH
LEVEL
WINDOWS
OVER
-
ALLOW
TO
SITE
MEASURE
-
REFER
TO
ELEVATION
TERRACE AREA
(CATHEDRAL CEILING OVER)
BALCONY
TERRACE
MAKE
UP
TABLE
ROBE
(2550MM HIGH CEILING)
(2550MM HIGH CEILING)
SECTION OF RAKED CEILING
FFL: 675.050
FIREPLACE + TV
LOW
HEIGHT
JOINERY
TILT UP WINDOWS
SD2136FSS
GLASS BALUSTRADE
GLASS ENTRY DOOR
TO BE 2400mm HIGH
WITH GLAZED
PANEL OVER.
EXPOSED BEAM TO
ENGINEER'S DETAILS
VERTICAL PAINTED STEEL
BALUSTRADE TO BALCONY
O O
FW
GLASS
BALUSTRADE
GLASS
BALUSTRADE
GLASS BALUSTRADE
FW
FW
5360 8820 9310 2270
6360 160 4400
110
2390 160 4070 110 4970 160 2270
6350
5820
230
4040
110
1510
110
580
5370
230
6520 11890 7350
900
160
550 4910 6410 5320
160
4920 2270
1500
5100
4450
1120
1500
230
4710
160
4290
160
1120
600
NOTE: ALL INTERNAL DOORS TO BE 2400MM HIGH
01
A202
01
A201
02
A201
02
A202
12170
230
900
370
230
4510
160
690
3600
160
1120
25760
3390 1200 780 8820 9910 1670
12170
1860
2410
2080
230
1220
1360
2680
230
25760
1940 1210 1680 1210 490 1940 3610 2110 3610 610 3620 1210 850 1670
160
METAL CLADDING ON
SIP PANEL TO
EXTERNAL WALL.
METAL CLADDING ON
SIP PANEL TO
EXTERNAL WALL.
METAL CLADDING ON
SIP PANEL TO
EXTERNAL WALL.
METAL CLADDING ON
SIP PANEL TO
EXTERNAL WALL.
ALL CONCRETE SLABS AND FOOTINGS SHALL BE DETERMINED BY SITE CLASSIFICATION AND AS2870
PROVIDE TERMITE PROTECTION IN ACCORDANCE WITH AS3660
ALL TIMBER FRAMING AND CONSTRUCTION MUST COMPLY WITH THE CURRENT VERSION OF THE TIMBER
FRAMING CODE AS1684 AND THE BCA
ALL EXTERNAL WALLS TO BE RENDERED AND PAINTED SIP PANELS UNLESS NOTED OTHERWISE ON THE
DRAWINGS. INSTALL TO MANUFACTURERS SPECIFICATIONS. REFER TO ELEVATIONS FOR LOCATION OF OTHER
EXTERNAL FINISHES INCLUDING METAL AND TIMBER CLADDING.
ALL INSULATION TO COMPLY WITH ENERGY RATING REPORT.
NOTES
PROVIDE SMOKE ALARMS IN ACCORDANCE WITH PART 3.7.2 OF THE BCA AND AS3786.WIRING TO AS3000
WINDOWS TO COMPLY WITH ENERGY RATING REQUIREMENTS AND TO COMPLY WITH ALL RELEVANT
WINDOW CODES AND STANDARDS.
ALL BUSHFIRE RATED CONSTRUCTION AND FIRE RATED SEPARATION MUST BE UNDERTAKEN IN
ACCORDANCE WITH THE BUILDING CODE OF AUSTRALIA AND ALL RELEVENT AUSTRALIAN STANDARDS.
ALL FIRE RATING CONSTRUCTION MUST BE CERTIFIED BY A QUALIFIED PROFESSIONAL.
01
A301
AW2112 AW2112
TW1136
STACKING SLIDER DOORS
AW2112
AW2136SSF
SD2145SSF
AW1609
(REFER
TO
ELEVATION)
SD2424SF
(REFER
TO
ELEVATION)
01
A302
FEATURE
WINDOW
SITE
MEASURE
PRIOR
TO
MANUFACTURE
HIGH
LEVEL
WINDOWS
OVER
AW2112
REFER TO WINDOW SCHEDULE FOR ALL WINDOW SIZES.
WINDOW SUPPLIER TO PROVIDE WINDOW SCHEDULE BY
FOR APPROVAL OF CLIENT PRIOR TO MANUFACTURE.
300
900
1200
1200
1290
600
5100
110 110
5320
600
1200
1510
910
600
3080
110
3100
110
1090
W07
W08
W09
W11
W12
W20
W14
W15
W16
W17
W18
W13
W21
W19
D/W UNDER
M/W UNDER
FRIDGE
510
1390
110
510
1940
110
1650
110
900
STUD FRAME FOR
CAVITY SLIDER
UP
SIP PANEL TO RUN THROUGH
WITH FRAMED OUT EXTERNAL
SECTION FOR STONE
CLADDING.
1090 110
1140
110
STUD FRAME TO CONCEAL
STRUCTURAL POST.
600
100
100
SKYLIGHTS OVER (x4)
Description
Rev drawn Date
Drawing Title
Drawing Number Rev
Date
Project Director
Project Architect Coord.
Reviewed
Verified
Approved
North
Scale Drawn
FLOOR PLAN
UPPER LEVEL
1:100(A3) A102
.
AL&CH
AL&CH
D
26.10.21
Project
BLOCK 1 SECTION 146 BONNER -
Client
JAMES AND ALISON FOLK
All dimensions are in millimetres. All levels are in metres.
Do not scale off drawing. All structure to engineers specification.
All dimensions, levels and site conditions must be verified
by contractor prior to commencement of any work.
All work must be carried out in accordance with the current edition
of the Building Code of Australia & all relevant Australian Standards.
C copyright: heyward lance architecture pty ltd
Reproduction of this design and/or document in whole or in part
without prior written consent is an infringement of copyright.
heyward lance architecture
147 amy ackman st : forde ACT 2914 p : 02 6255 4454
NOTES
COPYRIGHT
ISSUE FOR INFORMATION
P6 AL&CH 21.12.20
1N APPLICATION
P7 AL&CH 15.02.21
KITCHEN DIMENSIONS ADDED
P8 AL&CH 08.04.21
PROJECT NO: 2030
ISSUE FOR INFORMATION
A AL&CH 22.04.21
ISSUE FOR INFORMATION
B AL&CH 28.04.21
ISSUE FOR INFORMATION
C AL&CH 15.06.21
ISSUE FOR INFORMATION
D AL&CH 26.10.21