Our Products
Kenra Tech Products
Kenra Tech Products
Kenra Technologies & its group companies offer Switched Mode Power Supplies units with MIL grade specifications. We specialize in custom designed power supplies with single and multiple outputs. We design and manufacture SMPS units in both conducted and convection forced air cooling systems in varied sizes according to the customer requirements.
1. SL
NO
PART NUMBER INPUT OUTPUT
TOTAL
POWER
MIL-STAND
COMPLIANCE
SPECIAL FEATURES SIZE
PS-1: +9V/25A & -9V/5A TRACKING ≤ 0.2% LINE REGULATION
PS-2: +9V/25A & -9V/5A TRACKING ≤ 0.5% LOAD REGULATION
PS-3: +9V/25A & -9V/5A TRACKING ≤ 1% RIPPLE AND NOISE
PS-4: +9V/25A & -9V/5A TRACKING
TRACKING BETWEEN +VE AND -
VE OUTPUTS
PS-5: +5V/26A
OUTPUT REMOTE SENSING
WITH 3V LINE DROP
PS-6: +15V/14A & -15V/2A TRACKING
OUTPUT ADJUSTMENT
ACCESIBILITY (±1V)
PS-7: +28V/5A HEALTH STATUS ON RS-422
PS-1: +8.5V/25A & -8.5V/5A TRACKING
≤ 0.2% LINE AND ≤ 0.5%
LOAD REGULATION
PS-2: +8.5V/25A & -8.5V/5A TRACKING ≤ 1% RIPPLE AND NOISE
PS-3: +15V/5A
TRACKING BETWEEN +VE AND -
VE OUTPUTS
PS-4: +15V/5A
OUTPUT REMOTE SENSING
WITH 3V LINE DROP
PS-5: +5V/15A & -5V/2A TRACKING
OUTPUT ADJUSTMENT
ACCESIBILITY (±1V)
PS-6: +15V/7A & -15V/3A TRACKING HEALTH STATUS ON RS-422
PS-1: +24V/7A
≤ 0.2% LINE AND ≤ 0.5%
LOAD REGULATION
PS-2: +24V/7A
OUTPUT REMOTE SENSING
WITH 3V LINE DROP
PS-3: +24V/4A
OUTPUT ADJUSTMENT
ACCESIBILITY (±2V)
PS-4: +24V/2A HEALTH STATUS ON RS-422
PS-1: +28V/15A
OUTPUT ADJUSTMENT
ACCESIBILITY (+2V & -4V)
PS-2: +28V/10A INPUT REMOTE ON/OFF
PS-3: +28V/3A
LAN INTERFACING FOR TOTAL
SYSTEM
PS-4: +28V/2A
FLEXIBLE TO BOTH SLIDE
MOUNT AND HARD MOUNT
700W
4
KRPS 230V M 0K7 193U045 F
180VAC-
265VAC,
SINGLE
PHASE,
50Hz.
1.8KW
3
450mm X
482.6mm X
133mm
1
2 KRPS 230V M 1K5 196U056 F
180VAC-
265VAC,
SINGLE
PHASE,
50Hz.
1.5KW
566mm X
482.6mm X
246.5mm
UNIT OUTER VIEW
180VAC-
265VAC,
SINGLE
PHASE,
50Hz.
KRPS 230V M 1K8 196U056 F
566mm X
482.6mm X
246.5mm
1.2KW
400mm X
482.6mm X
89mm
180VAC-
265VAC,
SINGLE
PHASE,
50Hz.
KRPS 230V M 1K2 192U040 F
Designed to Meet MIL-
STD461-E
Designed to Meet JSS
55555 Navel services
(class N)Environmental
conditions
Designed to Meet MIL-
STD461-E
Designed to Meet JSS
55555 Navel services
(class N)Environmental
conditions
Designed to Meet MIL-
STD461-E
Designed to Meet JSS
55555 Navel services
(class N)Environmental
conditions
Designed to Meet MIL-
STD461-E
Designed to Meet JSS
55555 Navel services
(class N)Environmental
conditions
2. PS-1: +28V/10A
OUTPUT ADJUSTMENT
ACCESIBILITY (+2V & -4V)
PS-2: +28V/2A INPUT REMOTE ON/OFF
PS-3: +28V/3A
LAN INTERFACING FOR TOTAL
SYSTEM
PS-4: +28V/2A
FLEXIBLE TO BOTH SLIDE
MOUNT AND HARD MOUNT
PS-1: +28V/10A
Designed to Meet MIL-
STD461-E/F
≤ 0.2% LINE AND ≤ 0.5%
LOAD REGULATION
PS-2: +24V/8A
Designed to Meet JSS
55555 Land services
(class L)Environmental
conditions
OUTPUT REMOTE SENSING
WITH 3V LINE DROP
PS-1: +5V/10A
≤ 0.2% LINE AND ≤ 0.5%
LOAD REGULATION
PS-2: -15V/2A ≤ 1% RIPPLE AND NOISE
PS-3: +15V/10A CONDUCTION COOLED
PS-4: -9V/10A
TRACKING BETWEEN +VE AND -
VE OUTPUTS
PS-5: +9V/15A
OUTPUT REMOTE SENSING
WITH 3V LINE DROP
PS-6: +9V/15A
OUTPUT ADJUSTMENT
ACCESIBILITY (±1V)
PS-7: +9V/15A HEALTH STATUS ON RS-422
PS-1: +5V/5A
≤ 0.1% LINE AND LOAD
REGULATION
PS-2: +15V/1A ≤ 0.2% RIPPLE AND NOISE
PS-3: -5V/0.2A
PS-4: +5V/4A
PS-5: +28V/11A CONDUCTION COOLED
KHPS 28V M 0K4 101440 C
KHPS 230V M 0K6 302011 F
400W
100mm X
140mm X
40mm
180VAC-
265VAC,
SINGLE
PHASE,
50Hz.
520mm X
270mm X
97mm
18VDC -
36VDC
8
180VAC-
265VAC,
SINGLE
PHASE,
50Hz.
600W
300mm X
200mm X
115mm
5 700W
450mm X
482.6mm X
89mm
KRPS 230V M 0K7 192U040 F
180VAC-
265VAC,
SINGLE
PHASE,
50Hz.
6
1.2KW7 KHPS 230V M 1K2 522710 C
Designed to Meet JSS
55555 Air services
(class A)Environmental
conditions
LINE & LOAD REGULATION AND
RIPPLE 8mV FOR +5V & -5V
Designed to Meet MIL-
STD461-E
Designed to Meet JSS
55555 Navel services
(class N)Environmental
conditions
Designed to Meet MIL-
STD461-E/F
Designed to Meet JSS
55555 Land services
(class L)Environmental
conditions
Designed to Meet MIL-
STD461-E
3. PS-1: +27V/12A
≤ 0.2% LINE AND ≤ 0.5%
LOAD REGULATION
PS-2: +27V/3.7A ≤ 1% RIPPLE AND NOISE
PS-3: +27V/12A ≤ 1% RIPPLE AND NOISE
PS-4: +28V/9A CONDUCTION COOLED
PS-1: +5.5V/2A ≤ 0.2% LINE REGULATION
PS-2: +5.5V/2A
PS-3: +5.5V/2A
PS-4: +5.5V/1A
PS-5: -5.5V/0.5A
PS-6: -5.5V/0.5A
PS-7: +3.63V/3A
PS-8: +18V/0.5A
PS-1: +8.5V/3A ≤ 0.2% LINE REGULATION
PS-2: -8.5V/3A ≤ 0.5% LOAD REGULATION
PS-3: +5V/0.5A ≤ 1% RIPPLE AND NOISE
12 KPM 28V 5 25 050510 P
18VDC -
36VDC
+5V/5A 30W
Designed to Meet MIL-
STD461-F
PCB MOUNTABLE
CONFIGARATION AND
CONDUCTION COOLED
50mm X
50mm X
13mm
KHPS 28V M 1K0 211208 C 1KW
10
60mm X
94mm X
100mm
18VDC -
36VDC
9
215mm X
120mm X
80mm
80W
18VDC -
36VDC
KHPS 28V M 080 060910 C
Designed to Meet JSS
55555 Air services
(class A)Environmental
conditions
≤ 0.5% LOAD REGULATION
≤ 1% RIPPLE AND NOISE
CONDUCTION COOLED
180VAC-
265VAC,
SINGLE
PHASE,
50Hz.
11 KHPS 230V M 070 291613 F
290mm X
160mm X
130mm
Designed to Meet JSS
55555 Land services
(class L)Environmental
conditions
70W
Designed to Meet MIL-
STD461-E
Designed to Meet JSS
55555 Air services
(class A)Environmental
conditions
Designed to Meet MIL-
STD461-F