SlideShare a Scribd company logo
1 of 21
LG Academia de Ar
                    Condicionado
Automação para sistemas
      (VRF – R410A)


          Air Conditioning Academy
Network Solution




                                                                            Air Conditioning Division
Multi V   Copyright 2010 @LG Electronics / AC Company All Rights Reserved                           2
2 - Line Up
Controles Centralizados - Disponibilidade
                 Controles Centrais                                             Integração com rede aberta
             Controle & Sistema de
                Gerenciamento                                                          BMS Gate way


             Pequenos
              Edifícios



           Edifícios
            Médios
                                                                                   •          • BACnet
                                                                                LonWorks

           Total AC Manager
                 System
            Grandes
           Edifícios


                                                                                     Home Automation


                                                                                LGAP Protocol


 Multi V      Copyright 2010 @LG Electronics / AC Company All Rights Reserved                                3
3 - Controles
4 - AC Smart
      Para instalações de médio porte
           System Architecture
            System Architecture


                                                                                 Multi V System




                                                                                 MPS
                 Máximo
                                                                         PI485
             64 evaporadoras




              Possibilidade
             Expansão para
                  128
             Evaporadoras

 Multi V       Copyright 2010 @LG Electronics / AC Company All Rights Reserved                    4
3 - Controles
4 - AC Smart                              Acesso via Web Browser
                                                           Web Access
  Web Access Function is available basically, so you can access AC Smart anywhere by using Internet Explorer.
  Web Access level is distinguished to 2 Level; Administrator & User.
  When login to administrator: Can register user’s ID & Password (max 10 users), and allocate accessible address for
  each user; can operate all indoor
  When login to User: Can operate allocated indoor for each user.



                                                        Internet
                                          Internet
                                          Explorer




                                           4F user’s ID & PW                     4F

                                                                                 3F
                                           3F user’s ID & PW


                                           2F user’s ID & PW                     2F


                                           1F user’s ID & PW                     1F
                                                                                      Administrator can control all units

 Multi V       Copyright 2010 @LG Electronics / AC Company All Rights Reserved                                          5
3 - Controles
4 - AC Smart                                     Multi Linguagem
                                                      Multi Language

       On setting the language, all GUI will be changed to the selected language.
       [English, French, Spanish, Italian,German,Dutch,Russian]




 Multi V     Copyright 2010 @LG Electronics / AC Company All Rights Reserved        6
3 - Controles
4 - AC Smart                                  Modo Automático
                                                  Auto Changeover




                                                            • (sT : Set Temp.) :18~30℃
                                                         • dT (Difference Temp.) : 1~7℃
                                                              • aT (Alpha Temp.) : 2℃
                                        • Upper Limit (sT+dT+aT) : Change Point(Heat → Cool)
                                         • Lower Limit (sT-dT-aT) : Change Point(Cool → Heat)




 Multi V   Copyright 2010 @LG Electronics / AC Company All Rights Reserved                      7
3 - Controles                                                                                           4. AC Smart

4 - AC Smart                        Bloquear ou limitar temperatura
                                           Individual Function Control Locking
    If Function Locking is enabled in AC Smart, then you cannot change the locked function in the individual remocon.
   (For example, if Temperature is locked in the AC Smart, you can not change the setting temperature in the remocon,



                                                Energy
                                                Saving
                                                           26℃ Fix
                                                Temp
                                                 26℃



                                          temperature Change is impossible.
                                             Other function is possible.         Total, Mode,Temperature,Speed Lock


                                          Setting Temperature range restriction



                                                Energy
                                                Saving
                                                           24~28℃ adjustable
                                                Temp
                                                 26℃
                                24~28℃

                                           temperature Change is possible
                                          only in the range set from AC Smart


 Multi V       Copyright 2010 @LG Electronics / AC Company All Rights Reserved                                          8
3 - Controles
4 - AC Smart                              Parada de Emergência
                                                      Emergency Stop

   Connection with fire alarm in non_voltage contact.
   On detecting, all connected air_conditioner will be stop




   Back of the AC Smart

                                                 Fire Alarm Sensor

                                                                                               n
                                                                                          t io
                                                                                       ec n
                                                                                        e
                                                                                    etr
                                                                                    Fi rre
                                                                                   D u
                                                                                 re c
                                                  non_power contact            Fi Oc ce!




 Multi V     Copyright 2010 @LG Electronics / AC Company All Rights Reserved                       9
3 - Controles
4 - AC Smart                                        Fácil Upgrade
                                                       Easy Upgrade
 System Data Backup & Upload is Possible
                                      1. Save the target program to USB
             2. Connect “mini USB to Standard USB Jack(Get from communication equipment market)”
                                          to AC Smart and connect USB




       USB




                                                   It will take about 10 minutes.
                                             After completing upgrade, automatically
                                                              restart the
                                                         AC Smart Program,
                                                        then remove the USB.

 Multi V     Copyright 2010 @LG Electronics / AC Company All Rights Reserved                       10
3 - Controles
4 - AC Smart                        Expandir de 64 para 128 U.I
                                                    128 Expansion Kit

        By using Expansion Kit,
 Maximum 128 Indoor Unit can be connected




               Maximum 64 Units
               Maximum 128 Units


           When using Expansion Kit


                              128 Expansion Kit
                               (PQCSE440U0)

                                               AC 220V




 Multi V     Copyright 2010 @LG Electronics / AC Company All Rights Reserved   11
3 - Controles
4 - AC Smart                 Cálculo da participação de cada U.I
                                              Operation Ratio Calculation

       In AC Smart Monitoring, report of each indoor’s operation time & operation ratio, is available.
          By using this, you can distribute the power consumption by referring to the information.




                                                                               




 Multi V      Copyright 2010 @LG Electronics / AC Company All Rights Reserved                            12
3 - Controles
4 - AC Smart              Cálculo da participação de cada U.I




 Multi V   Copyright 2010 @LG Electronics / AC Company All Rights Reserved   13
3 - Controles
4 - AC Smart                            Controle do tempo de operação
                                                        Time Limit Control
      New Auto control of AC Smart, Time Limit control. You can set the time limit 1~4Hr, and set
                                                      available day of week.
           In time limit function for available period, indoors can operate up to maxim setting time
                                                            continuously.
    For example: Set as 2 Hr, and available on Saturday & Sunday. When someone operate indoor,
                                                            AC Smart will
                    check the continuous operating time. If the time is over 2hr, AC Smart
                                        automatically stops the indoor operation.




        Register group
   Limit Time Set : 1 ~ 4 hr.
  Set available day of week


                                      Turn On the air conditioner
                                           After limited time
                                   Automatically stop air conditioner


 Multi V         Copyright 2010 @LG Electronics / AC Company All Rights Reserved                       14
3 - Controles
4 - AC Smart                     Acesso como Administrador ou Usuário
                                                   Access Level (3 Level)

           In AC Smart controller access level is distinguished to 3 Level; Installer, Administrator & User.
     When login to Installer: Can register administrator & user’s ID & Password, and register Unit; can operate
                                                             all Function
            When login to Administrator: Can operate all Function except unit register, id & pw register.
                                 When login to User: Can operate only control & monitoring.




                   Log in for
                  installation
                 professional




                                                          Log in for   Log in for
                                                        administrator general user

 Multi V       Copyright 2010 @LG Electronics / AC Company All Rights Reserved                                    15
3 - Controles
4 - AC Smart                                        E-mail Automático
                                                              Auto e-mail

    New e-mail function was applied. By using this function, you can register e-mail address, so when
           error happen or some fixed time automatic e-mail will be executed. So customer can easily
                                       maintain all connected air conditioner’s status.




            4F

            3F


            2F


            1F
                               Internet
                    Auto e-mail sending




 Multi V         Copyright 2010 @LG Electronics / AC Company All Rights Reserved                       16
3 - Controles
4 - AC Smart                              Relógio digital na tela
                                                      Digital Watch


            When not using Central Controller, AC Smart can display Digital Watch




                                                       Screen Saver




 Multi V   Copyright 2010 @LG Electronics / AC Company All Rights Reserved          17
3 - Controles
7 - BAC Net Gateway junto com controle escravo




Multi V   Copyright 2010 @LG Electronics / AC Company All Rights Reserved   18
3 - Controles
8 - Do KIT : PQNFP00T0 – Controle de Dispositivos Externos
                                                     Do Unit connection

           By using Do Unit, AC Smart can control on/off of other equipment. It can easily register
                                    another equipment and control it.




                                               BUS_A
                                                                        Power of Load
                                               BUS_B




           ACP or ACSmart




                                                         Do KIT : PQNFP00T0



 Multi V       Copyright 2010 @LG Electronics / AC Company All Rights Reserved                        19
3 - Controles
8 - Do KIT : PQNFP00T0 – Controle de Dispositivos Externos

                                          Option : Do Kit (PQNFP00T0)




                                         Pump Power Source


 Multi V   Copyright 2010 @LG Electronics / AC Company All Rights Reserved   20
Multi V   Copyright 2010 @LG Electronics / AC Company All Rights Reserved   21

More Related Content

What's hot

Dmx512 lightng contrl design
Dmx512 lightng contrl designDmx512 lightng contrl design
Dmx512 lightng contrl designajsatienza
 
Data sheet en_us_1868002443
Data sheet en_us_1868002443Data sheet en_us_1868002443
Data sheet en_us_1868002443amthanhbosch
 
Advanced motion controls dzralte 040l080
Advanced motion controls dzralte 040l080Advanced motion controls dzralte 040l080
Advanced motion controls dzralte 040l080Electromate
 
74ls283datasheet
74ls283datasheet74ls283datasheet
74ls283datasheetneghy
 
Bdcom s2508 b hardware installation manual
Bdcom s2508 b hardware installation manualBdcom s2508 b hardware installation manual
Bdcom s2508 b hardware installation manualHARRY CHAN PUTRA
 
Data sheet en_us_1870416907
Data sheet en_us_1870416907Data sheet en_us_1870416907
Data sheet en_us_1870416907amthanhbosch
 
Powerlink® G3 Lighting Control Systems
Powerlink® G3 Lighting Control SystemsPowerlink® G3 Lighting Control Systems
Powerlink® G3 Lighting Control Systemsalexandriaweber
 
RFID PROJECTS ABSTRACT LIST-Rfid based access control and staff attendence ma...
RFID PROJECTS ABSTRACT LIST-Rfid based access control and staff attendence ma...RFID PROJECTS ABSTRACT LIST-Rfid based access control and staff attendence ma...
RFID PROJECTS ABSTRACT LIST-Rfid based access control and staff attendence ma...ASHOKKUMAR RAMAR
 
Data sheet en_us_1889956491
Data sheet en_us_1889956491Data sheet en_us_1889956491
Data sheet en_us_1889956491amthanhbosch
 
Advanced motion controls dzsantu 020b200
Advanced motion controls dzsantu 020b200Advanced motion controls dzsantu 020b200
Advanced motion controls dzsantu 020b200Electromate
 
Wohler Amp1-S8-3G new
Wohler Amp1-S8-3G newWohler Amp1-S8-3G new
Wohler Amp1-S8-3G newRadikal Ltd.
 

What's hot (19)

Vertx v100 ds_en
Vertx v100 ds_enVertx v100 ds_en
Vertx v100 ds_en
 
Dmx512 lightng contrl design
Dmx512 lightng contrl designDmx512 lightng contrl design
Dmx512 lightng contrl design
 
CATV Optical Transmitter
CATV Optical TransmitterCATV Optical Transmitter
CATV Optical Transmitter
 
Data sheet en_us_1868002443
Data sheet en_us_1868002443Data sheet en_us_1868002443
Data sheet en_us_1868002443
 
Advanced motion controls dzralte 040l080
Advanced motion controls dzralte 040l080Advanced motion controls dzralte 040l080
Advanced motion controls dzralte 040l080
 
74ls283datasheet
74ls283datasheet74ls283datasheet
74ls283datasheet
 
(EN) eBACgw-Biteck: BACnet GATEWAY FOR BITECK SMOKE ANALIZERS
(EN) eBACgw-Biteck: BACnet GATEWAY FOR BITECK SMOKE ANALIZERS(EN) eBACgw-Biteck: BACnet GATEWAY FOR BITECK SMOKE ANALIZERS
(EN) eBACgw-Biteck: BACnet GATEWAY FOR BITECK SMOKE ANALIZERS
 
Edgereadererp40 ds en
Edgereadererp40 ds enEdgereadererp40 ds en
Edgereadererp40 ds en
 
Bdcom s2508 b hardware installation manual
Bdcom s2508 b hardware installation manualBdcom s2508 b hardware installation manual
Bdcom s2508 b hardware installation manual
 
Data sheet en_us_1870416907
Data sheet en_us_1870416907Data sheet en_us_1870416907
Data sheet en_us_1870416907
 
Xu200
Xu200Xu200
Xu200
 
Powerlink® G3 Lighting Control Systems
Powerlink® G3 Lighting Control SystemsPowerlink® G3 Lighting Control Systems
Powerlink® G3 Lighting Control Systems
 
RFID PROJECTS ABSTRACT LIST-Rfid based access control and staff attendence ma...
RFID PROJECTS ABSTRACT LIST-Rfid based access control and staff attendence ma...RFID PROJECTS ABSTRACT LIST-Rfid based access control and staff attendence ma...
RFID PROJECTS ABSTRACT LIST-Rfid based access control and staff attendence ma...
 
Pca9532
Pca9532Pca9532
Pca9532
 
Data sheet en_us_1889956491
Data sheet en_us_1889956491Data sheet en_us_1889956491
Data sheet en_us_1889956491
 
Edgereaderer40 ds en
Edgereaderer40 ds enEdgereaderer40 ds en
Edgereaderer40 ds en
 
Advanced motion controls dzsantu 020b200
Advanced motion controls dzsantu 020b200Advanced motion controls dzsantu 020b200
Advanced motion controls dzsantu 020b200
 
Wohler Amp1-S8-3G new
Wohler Amp1-S8-3G newWohler Amp1-S8-3G new
Wohler Amp1-S8-3G new
 
Sony LMD-2341W
Sony LMD-2341WSony LMD-2341W
Sony LMD-2341W
 

Similar to LG Academia de Ar Condicionado Automação

BTech ECE project final report using Arduino
BTech ECE project final report using ArduinoBTech ECE project final report using Arduino
BTech ECE project final report using ArduinoBhuvi85107
 
IRJET - Transformers Monitoring using Arduino
IRJET -  	  Transformers Monitoring using ArduinoIRJET -  	  Transformers Monitoring using Arduino
IRJET - Transformers Monitoring using ArduinoIRJET Journal
 
SynTrust Solution Presentaion file-V16
SynTrust Solution Presentaion file-V16SynTrust Solution Presentaion file-V16
SynTrust Solution Presentaion file-V16Jason Chuang
 
7SC80 Feeder Automation Controller
7SC80 Feeder Automation Controller7SC80 Feeder Automation Controller
7SC80 Feeder Automation Controllerashwini reliserv
 
Ls catalog thiet bi tu dong imp intelligent motor_protectionrelay_e_0910
Ls catalog thiet bi tu dong imp intelligent motor_protectionrelay_e_0910Ls catalog thiet bi tu dong imp intelligent motor_protectionrelay_e_0910
Ls catalog thiet bi tu dong imp intelligent motor_protectionrelay_e_0910Dien Ha The
 
Ls catalog thiet bi tu dong imp intelligent motor_protectionrelay_e_0910_dien...
Ls catalog thiet bi tu dong imp intelligent motor_protectionrelay_e_0910_dien...Ls catalog thiet bi tu dong imp intelligent motor_protectionrelay_e_0910_dien...
Ls catalog thiet bi tu dong imp intelligent motor_protectionrelay_e_0910_dien...Dien Ha The
 
Digital Temperature Controllers
Digital Temperature ControllersDigital Temperature Controllers
Digital Temperature ControllersDwyer Instruments
 
Joseph Staniowski - Design Project
Joseph Staniowski - Design ProjectJoseph Staniowski - Design Project
Joseph Staniowski - Design ProjectJoseph Staniowski
 
Iai ethernet ip_pcon_acon_specsheet
Iai ethernet ip_pcon_acon_specsheetIai ethernet ip_pcon_acon_specsheet
Iai ethernet ip_pcon_acon_specsheetElectromate
 
Humidity sensor
Humidity sensorHumidity sensor
Humidity sensorlanjot
 
LayerZero Series 70: eRPP-FS Front/Side Access Remote Power Panel
LayerZero Series 70: eRPP-FS Front/Side Access Remote Power PanelLayerZero Series 70: eRPP-FS Front/Side Access Remote Power Panel
LayerZero Series 70: eRPP-FS Front/Side Access Remote Power PanelLayerZero Power Systems, Inc.
 
MPC of TWT based Transmitter
MPC of TWT based TransmitterMPC of TWT based Transmitter
MPC of TWT based TransmitterAbhishek Sutrave
 
MOX LT Home Automation
MOX LT Home AutomationMOX LT Home Automation
MOX LT Home Automationmoxreview
 
GridPoint\’s Energy Management System Intelligent Controllers
GridPoint\’s Energy Management System Intelligent ControllersGridPoint\’s Energy Management System Intelligent Controllers
GridPoint\’s Energy Management System Intelligent ControllersMichele_Zambrano333
 

Similar to LG Academia de Ar Condicionado Automação (20)

BTech ECE project final report using Arduino
BTech ECE project final report using ArduinoBTech ECE project final report using Arduino
BTech ECE project final report using Arduino
 
IRJET - Transformers Monitoring using Arduino
IRJET -  	  Transformers Monitoring using ArduinoIRJET -  	  Transformers Monitoring using Arduino
IRJET - Transformers Monitoring using Arduino
 
SynTrust Solution Presentaion file-V16
SynTrust Solution Presentaion file-V16SynTrust Solution Presentaion file-V16
SynTrust Solution Presentaion file-V16
 
7SC80 Feeder Automation Controller
7SC80 Feeder Automation Controller7SC80 Feeder Automation Controller
7SC80 Feeder Automation Controller
 
Ls catalog thiet bi tu dong imp intelligent motor_protectionrelay_e_0910
Ls catalog thiet bi tu dong imp intelligent motor_protectionrelay_e_0910Ls catalog thiet bi tu dong imp intelligent motor_protectionrelay_e_0910
Ls catalog thiet bi tu dong imp intelligent motor_protectionrelay_e_0910
 
Ls catalog thiet bi tu dong imp intelligent motor_protectionrelay_e_0910_dien...
Ls catalog thiet bi tu dong imp intelligent motor_protectionrelay_e_0910_dien...Ls catalog thiet bi tu dong imp intelligent motor_protectionrelay_e_0910_dien...
Ls catalog thiet bi tu dong imp intelligent motor_protectionrelay_e_0910_dien...
 
Digital Temperature Controllers
Digital Temperature ControllersDigital Temperature Controllers
Digital Temperature Controllers
 
Info sheet_TA5000
Info sheet_TA5000Info sheet_TA5000
Info sheet_TA5000
 
Joseph Staniowski - Design Project
Joseph Staniowski - Design ProjectJoseph Staniowski - Design Project
Joseph Staniowski - Design Project
 
E044081720
E044081720E044081720
E044081720
 
Introducing BriteSpot
Introducing BriteSpotIntroducing BriteSpot
Introducing BriteSpot
 
Iai ethernet ip_pcon_acon_specsheet
Iai ethernet ip_pcon_acon_specsheetIai ethernet ip_pcon_acon_specsheet
Iai ethernet ip_pcon_acon_specsheet
 
Humidity sensor
Humidity sensorHumidity sensor
Humidity sensor
 
LayerZero Series 70: eRPP-FS Front/Side Access Remote Power Panel
LayerZero Series 70: eRPP-FS Front/Side Access Remote Power PanelLayerZero Series 70: eRPP-FS Front/Side Access Remote Power Panel
LayerZero Series 70: eRPP-FS Front/Side Access Remote Power Panel
 
Ap psbias-1 p2-afr
Ap psbias-1 p2-afrAp psbias-1 p2-afr
Ap psbias-1 p2-afr
 
Ap psbias-1 p2-afr
Ap psbias-1 p2-afrAp psbias-1 p2-afr
Ap psbias-1 p2-afr
 
MPC of TWT based Transmitter
MPC of TWT based TransmitterMPC of TWT based Transmitter
MPC of TWT based Transmitter
 
MOX LT Home Automation
MOX LT Home AutomationMOX LT Home Automation
MOX LT Home Automation
 
Project
ProjectProject
Project
 
GridPoint\’s Energy Management System Intelligent Controllers
GridPoint\’s Energy Management System Intelligent ControllersGridPoint\’s Energy Management System Intelligent Controllers
GridPoint\’s Energy Management System Intelligent Controllers
 

More from Agassis Rodrigues

O que significa ter um direito
O que significa ter um direitoO que significa ter um direito
O que significa ter um direitoAgassis Rodrigues
 
Estatuto criança adolescente_comentado
Estatuto criança adolescente_comentadoEstatuto criança adolescente_comentado
Estatuto criança adolescente_comentadoAgassis Rodrigues
 
Defesa da defensoria do para
Defesa da defensoria do paraDefesa da defensoria do para
Defesa da defensoria do paraAgassis Rodrigues
 
Constituição federal anotada - stf
Constituição federal   anotada - stfConstituição federal   anotada - stf
Constituição federal anotada - stfAgassis Rodrigues
 
Como fazer uma redação dissertativa argumentativa
Como fazer uma redação dissertativa argumentativaComo fazer uma redação dissertativa argumentativa
Como fazer uma redação dissertativa argumentativaAgassis Rodrigues
 
44361736 lei-11-340-lei-maria-da-penha-comentada
44361736 lei-11-340-lei-maria-da-penha-comentada44361736 lei-11-340-lei-maria-da-penha-comentada
44361736 lei-11-340-lei-maria-da-penha-comentadaAgassis Rodrigues
 
Vale transporte como funciona
Vale transporte como funcionaVale transporte como funciona
Vale transporte como funcionaAgassis Rodrigues
 
Ada pelegrini-grinover-antonio-carlos-de-araujo-cintra-candido-rangel-dinamar...
Ada pelegrini-grinover-antonio-carlos-de-araujo-cintra-candido-rangel-dinamar...Ada pelegrini-grinover-antonio-carlos-de-araujo-cintra-candido-rangel-dinamar...
Ada pelegrini-grinover-antonio-carlos-de-araujo-cintra-candido-rangel-dinamar...Agassis Rodrigues
 
Aula iv fluxos reais e monetários
Aula iv fluxos reais e monetáriosAula iv fluxos reais e monetários
Aula iv fluxos reais e monetáriosAgassis Rodrigues
 
Aula iii estrutura de mercado
Aula iii estrutura de mercadoAula iii estrutura de mercado
Aula iii estrutura de mercadoAgassis Rodrigues
 

More from Agassis Rodrigues (20)

Termo ciência fabiola
Termo ciência fabiolaTermo ciência fabiola
Termo ciência fabiola
 
Reunião 13 08
Reunião 13 08Reunião 13 08
Reunião 13 08
 
Resumo acesso a justiça
Resumo acesso a justiçaResumo acesso a justiça
Resumo acesso a justiça
 
O que significa ter um direito
O que significa ter um direitoO que significa ter um direito
O que significa ter um direito
 
Manual tecnicas redacao
Manual tecnicas redacaoManual tecnicas redacao
Manual tecnicas redacao
 
Guia trabalho acadêmico
Guia trabalho acadêmicoGuia trabalho acadêmico
Guia trabalho acadêmico
 
Estatuto criança adolescente_comentado
Estatuto criança adolescente_comentadoEstatuto criança adolescente_comentado
Estatuto criança adolescente_comentado
 
Defesa da defensoria do para
Defesa da defensoria do paraDefesa da defensoria do para
Defesa da defensoria do para
 
Constituição federal anotada - stf
Constituição federal   anotada - stfConstituição federal   anotada - stf
Constituição federal anotada - stf
 
Como fazer uma redação dissertativa argumentativa
Como fazer uma redação dissertativa argumentativaComo fazer uma redação dissertativa argumentativa
Como fazer uma redação dissertativa argumentativa
 
C digo penal comentado
C digo penal comentadoC digo penal comentado
C digo penal comentado
 
44361736 lei-11-340-lei-maria-da-penha-comentada
44361736 lei-11-340-lei-maria-da-penha-comentada44361736 lei-11-340-lei-maria-da-penha-comentada
44361736 lei-11-340-lei-maria-da-penha-comentada
 
0027 primeiro aditamento
0027 primeiro aditamento0027 primeiro aditamento
0027 primeiro aditamento
 
Vale transporte como funciona
Vale transporte como funcionaVale transporte como funciona
Vale transporte como funciona
 
Ada pelegrini-grinover-antonio-carlos-de-araujo-cintra-candido-rangel-dinamar...
Ada pelegrini-grinover-antonio-carlos-de-araujo-cintra-candido-rangel-dinamar...Ada pelegrini-grinover-antonio-carlos-de-araujo-cintra-candido-rangel-dinamar...
Ada pelegrini-grinover-antonio-carlos-de-araujo-cintra-candido-rangel-dinamar...
 
Trabalho tgp
Trabalho tgpTrabalho tgp
Trabalho tgp
 
Mercado e concorrência
Mercado e concorrênciaMercado e concorrência
Mercado e concorrência
 
Aula iv fluxos reais e monetários
Aula iv fluxos reais e monetáriosAula iv fluxos reais e monetários
Aula iv fluxos reais e monetários
 
Aula iii estrutura de mercado
Aula iii estrutura de mercadoAula iii estrutura de mercado
Aula iii estrutura de mercado
 
Aula ii economia tópicos
Aula ii economia tópicosAula ii economia tópicos
Aula ii economia tópicos
 

LG Academia de Ar Condicionado Automação

  • 1. LG Academia de Ar Condicionado Automação para sistemas (VRF – R410A) Air Conditioning Academy
  • 2. Network Solution Air Conditioning Division Multi V Copyright 2010 @LG Electronics / AC Company All Rights Reserved 2
  • 3. 2 - Line Up Controles Centralizados - Disponibilidade Controles Centrais Integração com rede aberta Controle & Sistema de Gerenciamento BMS Gate way Pequenos Edifícios Edifícios Médios • • BACnet LonWorks Total AC Manager System Grandes Edifícios Home Automation LGAP Protocol Multi V Copyright 2010 @LG Electronics / AC Company All Rights Reserved 3
  • 4. 3 - Controles 4 - AC Smart Para instalações de médio porte System Architecture System Architecture Multi V System MPS Máximo PI485 64 evaporadoras Possibilidade Expansão para 128 Evaporadoras Multi V Copyright 2010 @LG Electronics / AC Company All Rights Reserved 4
  • 5. 3 - Controles 4 - AC Smart Acesso via Web Browser Web Access Web Access Function is available basically, so you can access AC Smart anywhere by using Internet Explorer. Web Access level is distinguished to 2 Level; Administrator & User. When login to administrator: Can register user’s ID & Password (max 10 users), and allocate accessible address for each user; can operate all indoor When login to User: Can operate allocated indoor for each user. Internet Internet Explorer 4F user’s ID & PW 4F 3F 3F user’s ID & PW 2F user’s ID & PW 2F 1F user’s ID & PW 1F Administrator can control all units Multi V Copyright 2010 @LG Electronics / AC Company All Rights Reserved 5
  • 6. 3 - Controles 4 - AC Smart Multi Linguagem Multi Language On setting the language, all GUI will be changed to the selected language. [English, French, Spanish, Italian,German,Dutch,Russian] Multi V Copyright 2010 @LG Electronics / AC Company All Rights Reserved 6
  • 7. 3 - Controles 4 - AC Smart Modo Automático Auto Changeover • (sT : Set Temp.) :18~30℃ • dT (Difference Temp.) : 1~7℃ • aT (Alpha Temp.) : 2℃ • Upper Limit (sT+dT+aT) : Change Point(Heat → Cool) • Lower Limit (sT-dT-aT) : Change Point(Cool → Heat) Multi V Copyright 2010 @LG Electronics / AC Company All Rights Reserved 7
  • 8. 3 - Controles 4. AC Smart 4 - AC Smart Bloquear ou limitar temperatura Individual Function Control Locking If Function Locking is enabled in AC Smart, then you cannot change the locked function in the individual remocon. (For example, if Temperature is locked in the AC Smart, you can not change the setting temperature in the remocon, Energy Saving 26℃ Fix Temp 26℃ temperature Change is impossible. Other function is possible. Total, Mode,Temperature,Speed Lock Setting Temperature range restriction Energy Saving 24~28℃ adjustable Temp 26℃ 24~28℃ temperature Change is possible only in the range set from AC Smart Multi V Copyright 2010 @LG Electronics / AC Company All Rights Reserved 8
  • 9. 3 - Controles 4 - AC Smart Parada de Emergência Emergency Stop Connection with fire alarm in non_voltage contact. On detecting, all connected air_conditioner will be stop Back of the AC Smart Fire Alarm Sensor n t io ec n e etr Fi rre D u re c non_power contact Fi Oc ce! Multi V Copyright 2010 @LG Electronics / AC Company All Rights Reserved 9
  • 10. 3 - Controles 4 - AC Smart Fácil Upgrade Easy Upgrade System Data Backup & Upload is Possible 1. Save the target program to USB 2. Connect “mini USB to Standard USB Jack(Get from communication equipment market)” to AC Smart and connect USB USB It will take about 10 minutes. After completing upgrade, automatically restart the AC Smart Program, then remove the USB. Multi V Copyright 2010 @LG Electronics / AC Company All Rights Reserved 10
  • 11. 3 - Controles 4 - AC Smart Expandir de 64 para 128 U.I 128 Expansion Kit By using Expansion Kit, Maximum 128 Indoor Unit can be connected Maximum 64 Units  Maximum 128 Units When using Expansion Kit 128 Expansion Kit (PQCSE440U0) AC 220V Multi V Copyright 2010 @LG Electronics / AC Company All Rights Reserved 11
  • 12. 3 - Controles 4 - AC Smart Cálculo da participação de cada U.I Operation Ratio Calculation In AC Smart Monitoring, report of each indoor’s operation time & operation ratio, is available. By using this, you can distribute the power consumption by referring to the information.   Multi V Copyright 2010 @LG Electronics / AC Company All Rights Reserved 12
  • 13. 3 - Controles 4 - AC Smart Cálculo da participação de cada U.I Multi V Copyright 2010 @LG Electronics / AC Company All Rights Reserved 13
  • 14. 3 - Controles 4 - AC Smart Controle do tempo de operação Time Limit Control New Auto control of AC Smart, Time Limit control. You can set the time limit 1~4Hr, and set available day of week. In time limit function for available period, indoors can operate up to maxim setting time continuously. For example: Set as 2 Hr, and available on Saturday & Sunday. When someone operate indoor, AC Smart will check the continuous operating time. If the time is over 2hr, AC Smart automatically stops the indoor operation. Register group Limit Time Set : 1 ~ 4 hr. Set available day of week Turn On the air conditioner After limited time Automatically stop air conditioner Multi V Copyright 2010 @LG Electronics / AC Company All Rights Reserved 14
  • 15. 3 - Controles 4 - AC Smart Acesso como Administrador ou Usuário Access Level (3 Level) In AC Smart controller access level is distinguished to 3 Level; Installer, Administrator & User. When login to Installer: Can register administrator & user’s ID & Password, and register Unit; can operate all Function When login to Administrator: Can operate all Function except unit register, id & pw register. When login to User: Can operate only control & monitoring. Log in for installation professional Log in for Log in for administrator general user Multi V Copyright 2010 @LG Electronics / AC Company All Rights Reserved 15
  • 16. 3 - Controles 4 - AC Smart E-mail Automático Auto e-mail New e-mail function was applied. By using this function, you can register e-mail address, so when error happen or some fixed time automatic e-mail will be executed. So customer can easily maintain all connected air conditioner’s status. 4F 3F 2F 1F Internet Auto e-mail sending Multi V Copyright 2010 @LG Electronics / AC Company All Rights Reserved 16
  • 17. 3 - Controles 4 - AC Smart Relógio digital na tela Digital Watch When not using Central Controller, AC Smart can display Digital Watch Screen Saver Multi V Copyright 2010 @LG Electronics / AC Company All Rights Reserved 17
  • 18. 3 - Controles 7 - BAC Net Gateway junto com controle escravo Multi V Copyright 2010 @LG Electronics / AC Company All Rights Reserved 18
  • 19. 3 - Controles 8 - Do KIT : PQNFP00T0 – Controle de Dispositivos Externos Do Unit connection By using Do Unit, AC Smart can control on/off of other equipment. It can easily register another equipment and control it. BUS_A Power of Load BUS_B ACP or ACSmart Do KIT : PQNFP00T0 Multi V Copyright 2010 @LG Electronics / AC Company All Rights Reserved 19
  • 20. 3 - Controles 8 - Do KIT : PQNFP00T0 – Controle de Dispositivos Externos Option : Do Kit (PQNFP00T0) Pump Power Source Multi V Copyright 2010 @LG Electronics / AC Company All Rights Reserved 20
  • 21. Multi V Copyright 2010 @LG Electronics / AC Company All Rights Reserved 21

Editor's Notes

  1. Lets have a look on the structure of the medium central controller and how it is connected to our airconditioner products.Here you can see a major point that our products are directly connected through RS-485 to the medium central controller. There is no need of CNU in between which makes the product economical solution to the market.
  2. Type Min. Description Method/Data 3 Explain the web access function in detail as shown above. The web access function differently indicates the indoor unit to control and monitor by empowering the adminstrator (Possible to set the right of user ID) e.g.) Possible to set the person in charge of the right of accessing by each floor. Key Word Web Access
  3. Type Min. Description Method/Data 2 How to access the language setting menu and how to select a language Select a supportable language and reboot to apply the language. Key Word Multi Language
  4. Type Min. Description Method/Data 5 Configure the auto changeover display on the screen. Concept of the auto changeover (setting temperature, highest/lowest temperature scope, etc.) Key Word Auto Control, Auto Changeover
  5. Type Min. Description Method/Data 5 Individual lock means, the other functions except the lock set are remotely controllable. Provide the menu of all lock, temperature/mode/air mode lock and temperature range lock. For example, if the temperature funciton locks, possible to change the temperature setting and change air mode and heating and cooling. Key Word Function locking
  6. Type Min. Description Method/Data 2 Explain how to install by using the image of the machine on the back side. AC Smart's logic operation at the fire alarm signal (Occurrence of the danger signal on the whole indoor unit) Key Word Fire Emergency Stop
  7. Type Min. Description Method/Data 3 How to access the menu How to upgrade the software (http://kic.lgeaircon.com) Function performance time (approximately 5~7 minutes) Check the mini USB terminal or the normal USB terminal and carefully download software. Key Word Software upgrade
  8. Type Min. Description Method/Data 3 Upon installing the 128MB memory expansion kit, possible to control up to 128 units. Refer to the image on how to install and check wiring. Key Word AC Smart, 128 expansion kit
  9. Type Min. Description Method/Data 3 The display on the reference of the power consumption lies in the history menu and the system contains the information on the daily consumption of the whole indoor unit for three months. Recommend to initialize after installation. Possible to monitor consumption by group, zone, and device in the condition setting and set the period. The daily consumption recording operate from 00:00 to 24:00, and if there is no consumption, the records are not made on the list of daily consumption. The consumption information is renewed every five minutes. Key Word Operation ratio calculation
  10. Type Min. Description Method/Data 3 Explain the time limit control in detail as shown above. The timelimit control function to automatically stop the product after the set time for saving energy Timelimit setting hours: 1~4 hrs (Possible to set by one hour) Key Word Time limit control
  11. Type Min. Description Method/Data 5 Explain how to access AC Smart in detail as shown above. AC Smart has three connection methods. ① For User : How to access for end users (Function limit to set up the system and check the history) ② For administrator : How to access for adminstrator (Function limit to register the unit and set up part of the system) ③ For installer : How to install and access for SVC (All functions allowable) ※ To access the installer, press the corner of the top on the left display approximately for three to five seconds. Key Word Access level
  12. Type Min. Description Method/Data 3 In case of the failure at email test after setup as in the manual, it is necessary to ask an internet service provider or a building IP-related service division regarding the matters on the itpop and smtp port. Key Word Auto e-mail,
  13. Type Min. Description Method/Data 2 Possible to set the screen saver on the setup menu and set up the time of operating the screen saver. Key Word Digital watch, AC smart
  14. Type Min. Description Method/Data 2 Above Image as shown is BACnet Connected to BMS by LAN cable. BACnet can control 256 Units .(AHU+ Vent.+ Aircon) Key Word Bacnet Installation
  15. Type Min. Description Method/Data 3 The above content is the description of the detailed installation plan for the Do Kit. Do Kit is an installation product for controlling the outside equipment when the central controller gives ON/OFF commands. Key Word Do Kit
  16. Key Word Do kit, installation Type Min. Description Method/Data 3 The above content is the description of the Do Kit line connection plan. ※ It is connected to the line by using the central controller and RS485 communication and it is also connected to control ON/OFF of the equipment.