1. 1
2
3
4
5
6
7
8
9
10
11
12
14
15
16
17
18
19
20
21
22
23
24
13
A
B
C
D
E
F
H
I
J
K
L
M
P
Speech Therapy
2
Speech Therapy
4
Book TR Room
5
Medical Store
6
Book TR Room
1
Unoccupied
Unoccupied
Unoccupied
Unoccupied
Unoccupied
Unoccupied
Unoccupied
Unoccupied
WC & Shower
8Staff WC
9
Hall
10
Womens Toilets
11
Mens Toilets
13
Wound Clinic
15
Medical Store
16
Wound Clinic
17
Bookable Room
18
Family Rm/Care Doc
19
Waiting Area
21Community Welfare
22
Bookable Room
23
Room
24
Child Health
25
Sound Proof Room
26
Unoccupied
Unoccupied
Womens WC
12
Mens WC
14
Circuit1
Panel 1
Coffer Light -
Parabolic
Rectangular
Reception
20
Circuit9
Panel 1
Coffer Light -
Parabolic
Rectangular
Circuit11
Panel 1
Coffer Light -
Parabolic
Rectangular
Circuit10
Panel 1
Coffer Light -
Parabolic
Rectangular
Circuit12
Panel 1
Coffer Light -
Parabolic
Rectangular
Circuit<unnamed>
Coffer Light -
Parabolic
Rectangular
Circuit6
Panel 2
Coffer Light -
Parabolic
Rectangular
Circuit5
Panel 2
Coffer Light -
Parabolic
Rectangular
Circuit4
Panel 2
Coffer Light -
Parabolic
Rectangular
Circuit3
Panel 2
Coffer Light -
Parabolic
Rectangular
Circuit2
Panel 2
Coffer Light -
Parabolic
Rectangular
Circuit1
Panel 2
Recessed
Direct-Indirect
Light -
Asymmetrical
Circuit8
Panel 1
Coffer Light -
Parabolic
Rectangular
Circuit7
Panel 1
Recessed
Direct-Indirect
Light -
Asymmetrical
Circuit6
Panel 1
Coffer Light -
Parabolic
Rectangular
Circuit5
Panel 1
Coffer Light -
Parabolic
Rectangular
Circuit4
Panel 1
Coffer Light -
Parabolic
Rectangular
Circuit3
Panel 1
Coffer Light -
Parabolic
Rectangular
Circuit11
Panel 2
Recessed
Direct-Indirect
Light -
Asymmetrical
Circuit12
Panel 2
Recessed
Direct-Indirect
Light -
Asymmetrical
Circuit8
Panel 3
Recessed
Direct-Indirect
Light -
Asymmetrical
Circuit7
Panel 3
Recessed
Direct-Indirect
Light -
Asymmetrical
Circuit3
Panel 3
Ceiling Light - Flat
Round
Recessed
Direct-Indirect
Light -
Asymmetrical
Circuit10
Panel 3
Coffer Light -
Parabolic
Rectangular
Circuit9
Panel 3
Coffer Light -
Parabolic
Rectangular
Circuit6
Panel 3
Coffer Light -
Parabolic
Rectangular
Circuit4
Panel 3
Coffer Light -
Parabolic
Rectangular
Circuit5
Panel 3
Coffer Light -
Parabolic
Rectangular
Circuit2
Panel 1
Recessed
Direct-Indirect
Light -
Asymmetrical
Coffer Light -
Parabolic
Rectangular
Scale
LECTURER
Drawn by
Date
Project number
Institute of Technology Carlow
BSc. in Architectural Technology
Year 3 2015-2016
1 : 200
21/04/201615:20:34
Electrical Plan Layout
3
Calow Primary Health Care Centre
Issue Date
Xhevdet Haliti
Dan O Sullivan, Noel Dunne,
Mark Duffy
A101
1 : 200
Ground floor - Ceiling
Electrical layout1
Notes:
Total Est. Demand Current: 6 A
Total Conn. Current: 9 A
Total Est. Demand: 4034 VA
Other 0 VA 0.00% 0 VA Total Conn. Load: 6112 VA
Lighting - Dwelling Unit 6112 VA 66.00% 4034 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Total Amps: 7 A 10 A 11 A
1504 VA 2208 VA 2400 VA
12 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.1 A
11 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.1 A
10 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.1 A
9 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A
8 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 4.2 A
7 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.7 A
6 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A
5 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A
4 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.4 A
3 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A
2 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 0.6 A
1 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.4 A
Circuit
Number
Circuit
Designation Type of Wiring
Circuit Conductors (csa) Live,
Neutral, CPC
Max
Disconnection
Time allowed
by BS7671
Protective
Device
BS(EN)
PD Type
number PD Rating
Short
Circuit
Capacity
(kA)
RCD
Operating
current (mA)
Maximum Zs
Permitted by
BS 7671
A B C
Notes:
Enclosure: Type 1 MCB Rating:
Mounting Type: Surface Mains Rating: 100 A
DB supplied from: No. of Phases: 3 Mains Type:
Location of DB: Space 1 Voltage: 230/400 Wye A.I.C. Rating:
DB Schedule: Panel 1
Institute of
Technology Carlow
Notes:
Total Est. Demand Current: 6 A
Total Conn. Current: 9 A
Total Est. Demand: 4245 VA
Other 0 VA 0.00% 0 VA Total Conn. Load: 6432 VA
Lighting - Dwelling Unit 6432 VA 66.00% 4245 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Total Amps: 7 A 12 A 9 A
1600 VA 2784 VA 2048 VA
12 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.2 A
11 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 5.3 A
10 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.1 A
9 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.1 A
8 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 0.6 A
7 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 0.8 A
6 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A
5 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A
4 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A
3 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A
2 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 3.5 A
1 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.2 A
Circuit
Number
Circuit
Designation Type of Wiring
Circuit Conductors (csa) Live,
Neutral, CPC
Max
Disconnection
Time allowed
by BS7671
Protective
Device
BS(EN)
PD Type
number PD Rating
Short
Circuit
Capacity
(kA)
RCD
Operating
current (mA)
Maximum Zs
Permitted by
BS 7671
A B C
Notes:
Enclosure: Type 1 MCB Rating:
Mounting Type: Surface Mains Rating: 100 A
DB supplied from: No. of Phases: 3 Mains Type:
Location of DB: Space 1 Voltage: 230/400 Wye A.I.C. Rating:
DB Schedule: Panel 2
Institure of
Technology Carlow
Symmetrical design, no required top or bottom mountings
Single-piece deadfront – no filler plates needed
Smaller, lighter panel than Spectra Series panelboards
Easy-to-install galvanized enclosures with removable endwalls
Ready-to-install hinged trim options
Branch-bus direct connection
Up to 600A breaker mounted as a branch device
Deeper (8"), wider (30") A-Series box to accommodate larger wire sizes
Double branched 150A (ED/SE) and 225A (QD) breakers
Vertically mounted main circuit breakers in 800A
Captive hardware on branch breakers
Staggered, center-mounted, larger frame breakers (SG, SF) for easy installation
Bus-connected TVSS for maximum surge protection
Narrow design to minimize footprint
Enclosure available in NEMA Type 1, Type 3R/12, Type 4/4X
An exceptional general lighting product that performs well in large
spaces with high ceilings. Especially suitable for open office areas,
public indoor spaces, libraries and airport waiting areas.
Moon Two - High frequency direct / indirect recessed luminaires are a range of
high efficiency luminaires designed to accommodate PL-L & T5 fluorescent
lamps. These are suitable for general lighting in retail & commercial applications.
Typical electrical room layout with suspended ceiling
and recessed coffer lighting shown.
Distrobution panel boards locate at Basement