SlideShare a Scribd company logo
1 of 4
Name Muhammad Talha Saeed
Reg. # 19-NTU-TE-0129
Experiment 4:
Demonstrate the behavior of semiconductor diodes in half-wave and full-wave
rectifiers both with and without capacitor filter
Apparatus:
Electro-Technic Lab Trainer,
Oscilloscope,
Digital Multi-meter,
Connecting leads.
Half-wave rectifier without and with capacitor filter
Circuit Diagram
a) b)
Figure 1 Half-wave rectifier a) without and b) with capacitor filter
Procedure
1. Connect the circuit as shown in Figure 8 a) using Electro-technic Lab Trainer and
Connecting leads.
2. Connect one of the probes of the oscilloscope across the output terminals of the transformer
and the second probe across the load resistor R.
3. Turn on the scope, set the channel selector to “Dual” mode, and coupling to DC. View both
of the signals simultaneously with proper voltage and position setting.
4. Set the selector switch of the multi-meter at AC voltage range.
5. Measure the AC voltage across the output terminals of the transformer using DMM and
record the reading.
11.31 V
6. Measure the DC voltage across the load resistor with the help of digital multi-meter and
record.
4.78 V
7. Paste picture of the output voltage observed by the oscilloscope in the following chart.
WhatsApp Video 2022-04-04 at 11.30.42 AM.mp4
Double click on video icon to open this
8. Measure the output frequency and record.
T = 4x5 ms = 20 ms = 0.02 s
f = 1/T = 1/0.02
f = 50 Hz
9. Measure the peak value of the output voltage of the half-wave rectifier with the help of
oscilloscope and record.
= 3.4 x 5
= 17
10. Now, connect the capacitor filter across the load resistor as in Figure 8 b).
11. Paste picture of the output voltage observed by the oscilloscope in the following chart.
WhatsApp Video 2022-04-04 at 11.30.42 AM (1).mp4
Double click on video icon to open this
Full-wave rectifier without and with capacitor filter
Circuit Diagram
a) b)
Figure 2 Full-wave rectifier a) without and b) with capacitor filter
Procedure
1. Connect the circuit as shown in Figure 9 a) using Electro-technic Lab Trainer and
Connecting leads.
2. Connect one of the probes of the oscilloscope across the output terminals of the transformer
and the second probe across the load resistor R.
3. Turn on the scope, set the channel selector to “Dual” mode, and coupling to DC. View both
of the signals simultaneously with proper voltage and position setting.
4. Set the selector switch of the multi-meter at AC voltage range.
5. Measure the AC voltage across the output terminals of the transformer using DMM and
record the reading.
11.05 V
6. Measure the DC voltage across the load resistor with the help of multi-meter and record.
8.74 V
7. Measure the peak value of the output of the full-wave rectifier with the help of oscilloscope
and record.
= 3.3 x 5
= 17
8. Measure the output frequency and record.
T = 2x5 ms = 10 ms = 0.01 s
f = 1/T = 1/0.01
f = 100 Hz
9. Paste picture of the output voltage observed by the oscilloscope in the following chart.
WhatsApp Video 2022-04-04 at 11.30.43 AM (1).mp4
Double click on video icon to open this
10. Now, connect the capacitor filter across the load resistor as in Figure 9 b).
11. Paste picture of the output voltage observed by the oscilloscope in the following chart.
WhatsApp Video 2022-04-04 at 11.30.43 AM (3).mp4
Double click on video icon to open this
Interpretation and Analysis
Is there any frequency difference between half- and full-wave rectifier? If yes, then
why?
Yes frequency is different in half wave and full wave rectifier for same input frequency. In half
wave the output frequency is same as input frequency. As it allows only a half cycle of AC
input voltage. While in case of full wave rectifier the output frequency is twice the input
frequency as it allows full cycle of AC input voltages to pass.
Is there any difference between magnitude of DC output voltage of half- and full-wave
rectifier? If yes, then why?
Yes there is difference between magnitude of DC output voltage of Half and Full-wave
rectifier. Because in half wave only half input cycle is rectified while in full wave whole cycle
is rectified so out put voltage of full wave rectifier is higher.
Conclusion
From the experiment, results and above discussion it is concluded that both half wave and full
wave rectifiers are used to transform AC into pulsating DC. Only the variation is the utilization
of an applied input signal. However, pulsating dc output shows that some AC ripples are also
present in it. So, it must be as small as possible. But the AC ripples in case of half wave
rectifier is somewhat more as compared to full wave rectifier.

More Related Content

Similar to EE Lab 4 Manual.docx

Performance Evaluation of Nine Level Modified CHB Multilevel Inverter for Var...
Performance Evaluation of Nine Level Modified CHB Multilevel Inverter for Var...Performance Evaluation of Nine Level Modified CHB Multilevel Inverter for Var...
Performance Evaluation of Nine Level Modified CHB Multilevel Inverter for Var...IJMER
 
A Simple Strategy of Controlling a Balanced Voltage Capacitor in Single Phase...
A Simple Strategy of Controlling a Balanced Voltage Capacitor in Single Phase...A Simple Strategy of Controlling a Balanced Voltage Capacitor in Single Phase...
A Simple Strategy of Controlling a Balanced Voltage Capacitor in Single Phase...IAES-IJPEDS
 
Switching Voltage Regulator
Switching Voltage RegulatorSwitching Voltage Regulator
Switching Voltage Regulatoribercovich
 
Pulse amplitude modulation
Pulse amplitude modulationPulse amplitude modulation
Pulse amplitude modulationVishal kakade
 
A Non-isolated Hybrid Boost Three Level DC-DC Converter with High Step-up Con...
A Non-isolated Hybrid Boost Three Level DC-DC Converter with High Step-up Con...A Non-isolated Hybrid Boost Three Level DC-DC Converter with High Step-up Con...
A Non-isolated Hybrid Boost Three Level DC-DC Converter with High Step-up Con...IJSRD
 
A new precision peak detector full wave rectifier
A new precision peak detector full wave rectifierA new precision peak detector full wave rectifier
A new precision peak detector full wave rectifierVishal kakade
 
Introduction to Oscilloscope and Function generator
Introduction to Oscilloscope and Function generatorIntroduction to Oscilloscope and Function generator
Introduction to Oscilloscope and Function generatorcyberns_
 
Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...
Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...
Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...IJERD Editor
 
Investigation of THD for Cascaded Multi-Level Inverter Using Multicarrier Mod...
Investigation of THD for Cascaded Multi-Level Inverter Using Multicarrier Mod...Investigation of THD for Cascaded Multi-Level Inverter Using Multicarrier Mod...
Investigation of THD for Cascaded Multi-Level Inverter Using Multicarrier Mod...IJERA Editor
 
COMPREHENSIVE ANALYSIS AND SIMULATION OF MULTILEVEL POWER CONVERTERS TO CURTA...
COMPREHENSIVE ANALYSIS AND SIMULATION OF MULTILEVEL POWER CONVERTERS TO CURTA...COMPREHENSIVE ANALYSIS AND SIMULATION OF MULTILEVEL POWER CONVERTERS TO CURTA...
COMPREHENSIVE ANALYSIS AND SIMULATION OF MULTILEVEL POWER CONVERTERS TO CURTA...ecij
 
COMPREHENSIVE ANALYSIS AND SIMULATION OF MULTILEVEL POWER CONVERTERS TO CURTA...
COMPREHENSIVE ANALYSIS AND SIMULATION OF MULTILEVEL POWER CONVERTERS TO CURTA...COMPREHENSIVE ANALYSIS AND SIMULATION OF MULTILEVEL POWER CONVERTERS TO CURTA...
COMPREHENSIVE ANALYSIS AND SIMULATION OF MULTILEVEL POWER CONVERTERS TO CURTA...ecij
 
Multilevel inverter fault detectiion classification and diagnosis
Multilevel inverter fault detectiion classification and diagnosisMultilevel inverter fault detectiion classification and diagnosis
Multilevel inverter fault detectiion classification and diagnosissuryakant tripathi
 
Modified Bidirectional Converter with Current Fed Inverter
Modified Bidirectional Converter with Current Fed InverterModified Bidirectional Converter with Current Fed Inverter
Modified Bidirectional Converter with Current Fed InverterIJPEDS-IAES
 

Similar to EE Lab 4 Manual.docx (20)

Pdc lab manualnew
Pdc lab manualnewPdc lab manualnew
Pdc lab manualnew
 
Gopi 1 lab manual
Gopi 1 lab manualGopi 1 lab manual
Gopi 1 lab manual
 
Experiment 4
Experiment 4Experiment 4
Experiment 4
 
Performance Evaluation of Nine Level Modified CHB Multilevel Inverter for Var...
Performance Evaluation of Nine Level Modified CHB Multilevel Inverter for Var...Performance Evaluation of Nine Level Modified CHB Multilevel Inverter for Var...
Performance Evaluation of Nine Level Modified CHB Multilevel Inverter for Var...
 
A Simple Strategy of Controlling a Balanced Voltage Capacitor in Single Phase...
A Simple Strategy of Controlling a Balanced Voltage Capacitor in Single Phase...A Simple Strategy of Controlling a Balanced Voltage Capacitor in Single Phase...
A Simple Strategy of Controlling a Balanced Voltage Capacitor in Single Phase...
 
D05432435
D05432435D05432435
D05432435
 
Solved problems on rectifiers
Solved problems  on rectifiersSolved problems  on rectifiers
Solved problems on rectifiers
 
Lab1
Lab1Lab1
Lab1
 
Switching Voltage Regulator
Switching Voltage RegulatorSwitching Voltage Regulator
Switching Voltage Regulator
 
Pulse amplitude modulation
Pulse amplitude modulationPulse amplitude modulation
Pulse amplitude modulation
 
A Non-isolated Hybrid Boost Three Level DC-DC Converter with High Step-up Con...
A Non-isolated Hybrid Boost Three Level DC-DC Converter with High Step-up Con...A Non-isolated Hybrid Boost Three Level DC-DC Converter with High Step-up Con...
A Non-isolated Hybrid Boost Three Level DC-DC Converter with High Step-up Con...
 
A new precision peak detector full wave rectifier
A new precision peak detector full wave rectifierA new precision peak detector full wave rectifier
A new precision peak detector full wave rectifier
 
Introduction to Oscilloscope and Function generator
Introduction to Oscilloscope and Function generatorIntroduction to Oscilloscope and Function generator
Introduction to Oscilloscope and Function generator
 
Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...
Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...
Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...
 
[IJET V2I5P10] Authors: Vinith Das, Dr. Babu Paul, Prof. Elizabeth Seba stian
[IJET V2I5P10] Authors: Vinith Das, Dr. Babu Paul, Prof. Elizabeth Seba stian [IJET V2I5P10] Authors: Vinith Das, Dr. Babu Paul, Prof. Elizabeth Seba stian
[IJET V2I5P10] Authors: Vinith Das, Dr. Babu Paul, Prof. Elizabeth Seba stian
 
Investigation of THD for Cascaded Multi-Level Inverter Using Multicarrier Mod...
Investigation of THD for Cascaded Multi-Level Inverter Using Multicarrier Mod...Investigation of THD for Cascaded Multi-Level Inverter Using Multicarrier Mod...
Investigation of THD for Cascaded Multi-Level Inverter Using Multicarrier Mod...
 
COMPREHENSIVE ANALYSIS AND SIMULATION OF MULTILEVEL POWER CONVERTERS TO CURTA...
COMPREHENSIVE ANALYSIS AND SIMULATION OF MULTILEVEL POWER CONVERTERS TO CURTA...COMPREHENSIVE ANALYSIS AND SIMULATION OF MULTILEVEL POWER CONVERTERS TO CURTA...
COMPREHENSIVE ANALYSIS AND SIMULATION OF MULTILEVEL POWER CONVERTERS TO CURTA...
 
COMPREHENSIVE ANALYSIS AND SIMULATION OF MULTILEVEL POWER CONVERTERS TO CURTA...
COMPREHENSIVE ANALYSIS AND SIMULATION OF MULTILEVEL POWER CONVERTERS TO CURTA...COMPREHENSIVE ANALYSIS AND SIMULATION OF MULTILEVEL POWER CONVERTERS TO CURTA...
COMPREHENSIVE ANALYSIS AND SIMULATION OF MULTILEVEL POWER CONVERTERS TO CURTA...
 
Multilevel inverter fault detectiion classification and diagnosis
Multilevel inverter fault detectiion classification and diagnosisMultilevel inverter fault detectiion classification and diagnosis
Multilevel inverter fault detectiion classification and diagnosis
 
Modified Bidirectional Converter with Current Fed Inverter
Modified Bidirectional Converter with Current Fed InverterModified Bidirectional Converter with Current Fed Inverter
Modified Bidirectional Converter with Current Fed Inverter
 

Recently uploaded

College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...ranjana rawat
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINESIVASHANKAR N
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...Call Girls in Nagpur High Profile
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxupamatechverse
 
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).pptssuser5c9d4b1
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130Suhani Kapoor
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxpranjaldaimarysona
 
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptx
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptxthe ladakh protest in leh ladakh 2024 sonam wangchuk.pptx
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptxhumanexperienceaaa
 
Extrusion Processes and Their Limitations
Extrusion Processes and Their LimitationsExtrusion Processes and Their Limitations
Extrusion Processes and Their Limitations120cr0395
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Dr.Costas Sachpazis
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVRajaP95
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingrakeshbaidya232001
 
(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...
(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...
(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...ranjana rawat
 
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...ranjana rawat
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxAsutosh Ranjan
 

Recently uploaded (20)

College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptx
 
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
 
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCRCall Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptx
 
Roadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and RoutesRoadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and Routes
 
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
 
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptx
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptxthe ladakh protest in leh ladakh 2024 sonam wangchuk.pptx
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptx
 
Extrusion Processes and Their Limitations
Extrusion Processes and Their LimitationsExtrusion Processes and Their Limitations
Extrusion Processes and Their Limitations
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
 
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writing
 
(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...
(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...
(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...
 
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptx
 

EE Lab 4 Manual.docx

  • 1. Name Muhammad Talha Saeed Reg. # 19-NTU-TE-0129 Experiment 4: Demonstrate the behavior of semiconductor diodes in half-wave and full-wave rectifiers both with and without capacitor filter Apparatus: Electro-Technic Lab Trainer, Oscilloscope, Digital Multi-meter, Connecting leads. Half-wave rectifier without and with capacitor filter Circuit Diagram a) b) Figure 1 Half-wave rectifier a) without and b) with capacitor filter Procedure 1. Connect the circuit as shown in Figure 8 a) using Electro-technic Lab Trainer and Connecting leads. 2. Connect one of the probes of the oscilloscope across the output terminals of the transformer and the second probe across the load resistor R. 3. Turn on the scope, set the channel selector to “Dual” mode, and coupling to DC. View both of the signals simultaneously with proper voltage and position setting. 4. Set the selector switch of the multi-meter at AC voltage range. 5. Measure the AC voltage across the output terminals of the transformer using DMM and record the reading. 11.31 V
  • 2. 6. Measure the DC voltage across the load resistor with the help of digital multi-meter and record. 4.78 V 7. Paste picture of the output voltage observed by the oscilloscope in the following chart. WhatsApp Video 2022-04-04 at 11.30.42 AM.mp4 Double click on video icon to open this 8. Measure the output frequency and record. T = 4x5 ms = 20 ms = 0.02 s f = 1/T = 1/0.02 f = 50 Hz 9. Measure the peak value of the output voltage of the half-wave rectifier with the help of oscilloscope and record. = 3.4 x 5 = 17 10. Now, connect the capacitor filter across the load resistor as in Figure 8 b). 11. Paste picture of the output voltage observed by the oscilloscope in the following chart. WhatsApp Video 2022-04-04 at 11.30.42 AM (1).mp4 Double click on video icon to open this
  • 3. Full-wave rectifier without and with capacitor filter Circuit Diagram a) b) Figure 2 Full-wave rectifier a) without and b) with capacitor filter Procedure 1. Connect the circuit as shown in Figure 9 a) using Electro-technic Lab Trainer and Connecting leads. 2. Connect one of the probes of the oscilloscope across the output terminals of the transformer and the second probe across the load resistor R. 3. Turn on the scope, set the channel selector to “Dual” mode, and coupling to DC. View both of the signals simultaneously with proper voltage and position setting. 4. Set the selector switch of the multi-meter at AC voltage range. 5. Measure the AC voltage across the output terminals of the transformer using DMM and record the reading. 11.05 V 6. Measure the DC voltage across the load resistor with the help of multi-meter and record. 8.74 V 7. Measure the peak value of the output of the full-wave rectifier with the help of oscilloscope and record. = 3.3 x 5 = 17 8. Measure the output frequency and record. T = 2x5 ms = 10 ms = 0.01 s f = 1/T = 1/0.01 f = 100 Hz 9. Paste picture of the output voltage observed by the oscilloscope in the following chart.
  • 4. WhatsApp Video 2022-04-04 at 11.30.43 AM (1).mp4 Double click on video icon to open this 10. Now, connect the capacitor filter across the load resistor as in Figure 9 b). 11. Paste picture of the output voltage observed by the oscilloscope in the following chart. WhatsApp Video 2022-04-04 at 11.30.43 AM (3).mp4 Double click on video icon to open this Interpretation and Analysis Is there any frequency difference between half- and full-wave rectifier? If yes, then why? Yes frequency is different in half wave and full wave rectifier for same input frequency. In half wave the output frequency is same as input frequency. As it allows only a half cycle of AC input voltage. While in case of full wave rectifier the output frequency is twice the input frequency as it allows full cycle of AC input voltages to pass. Is there any difference between magnitude of DC output voltage of half- and full-wave rectifier? If yes, then why? Yes there is difference between magnitude of DC output voltage of Half and Full-wave rectifier. Because in half wave only half input cycle is rectified while in full wave whole cycle is rectified so out put voltage of full wave rectifier is higher. Conclusion From the experiment, results and above discussion it is concluded that both half wave and full wave rectifiers are used to transform AC into pulsating DC. Only the variation is the utilization of an applied input signal. However, pulsating dc output shows that some AC ripples are also present in it. So, it must be as small as possible. But the AC ripples in case of half wave rectifier is somewhat more as compared to full wave rectifier.