Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 1
DESIGN AND FABRICATION OF FLOW-FOCUSING
DEVICES FOR TISSUE ENGINEERING APPLICATIONS
SAMUEL HOTALING
ADVISOR: DR. RACHAEL OLDINSKI
ABSTRACT
While the lifespan of humans has increased, the durability of cartilage has not, leading to increasing rates
of arthritis in aging humans. As both natural and surgical methods for repairing osteochondral defects tend to
fall short, UVM’s Engineered Biomaterials Research Laboratory (EBRL) is working towards a solution where
biomimetic, polymeric, and porous engineered tissue scaffolds are seeded with drugs and human
mesenchymal stem cells (hMSCs). The seeded scaffold is then implanted or injected into the patient’s
osteochondral defect, where the hMSCs differentiate and grow a new cartilaginous extracellular matrix to
heal the defect as the artificial scaffold breaks down.
Microspheres in three distinct size ranges are required to create pores and embed drugs and cells in the
scaffold. In order to produce these microspheres, we turn to the field of microfluidics, which examines fluid
interactions at micro-scale geometries and flow rates. A microfluidic flow-focusing device (MFFD) leverages
the low Reynolds numbers and pronounced effects of surface tension in such flows to create highly
monodisperse droplets of one fluid in a second.
This project investigates the design and fabrication of MFFDs for the production of homogeneous
microspheres. A MFFD must be consistently reproducible, readily characterized, and easy to test and use.
MFFDs show great potential to successfully play a role in the EBRL’s investigation of engineered tissue
scaffolds.
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 2
TABLE OF CONTENTS
Abstract....................................................................................................................................................................................................... 1
Table of Contents.................................................................................................................................................................................... 2
Table of Figures....................................................................................................................................................................................... 3
Motivation.................................................................................................................................................................................................. 4
Background............................................................................................................................................................................................... 4
Microfluidics....................................................................................................................................................................................... 4
Types of Droplet Generators ....................................................................................................................................................... 4
Relevant Fluid Parameters........................................................................................................................................................... 5
Flow-Focusing Dynamics .............................................................................................................................................................. 6
The Jetting Regime..................................................................................................................................................................... 6
The Dripping Regime................................................................................................................................................................ 6
Fabrication Methods for Microfluidic Flow-Focusing Devices..................................................................................... 7
Objectives................................................................................................................................................................................................... 8
Methods ...................................................................................................................................................................................................... 8
Device Fabrication Procedure..................................................................................................................................................... 9
Overview......................................................................................................................................................................................... 9
Making the Mold.......................................................................................................................................................................... 9
Making a Device.........................................................................................................................................................................10
Device Evaluation...........................................................................................................................................................................12
Device Testing..................................................................................................................................................................................12
Results and Discussion.......................................................................................................................................................................13
Mold Characterization..................................................................................................................................................................13
Device Characterization...............................................................................................................................................................14
Videography Data...........................................................................................................................................................................16
Dripping Behavior....................................................................................................................................................................16
Jetting Behavior.........................................................................................................................................................................17
Summary ..................................................................................................................................................................................................18
Conclusions .............................................................................................................................................................................................18
Future Work ...........................................................................................................................................................................................19
Acknowledgements .............................................................................................................................................................................19
Appendix ..................................................................................................................................................................................................20
Matlab Code.......................................................................................................................................................................................20
Channel Measurement Analysis and Plotting ..............................................................................................................20
Video Analysis and Plotting .................................................................................................................................................20
Viscosity Plotting (example)................................................................................................................................................21
Bibliography ...........................................................................................................................................................................................21
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 3
TABLE OF FIGURES
Figure 1: Flow-Focusing Configurations............................................................................................................................................... 5
Figure 2: Fabrication Overview ................................................................................................................................................................ 9
Figure 3: Bad Spin-Coating.......................................................................................................................................................................... 9
Figure 4: Good Spin-Coating....................................................................................................................................................................... 9
Figure 5: X-Junction, 10x............................................................................................................................................................................10
Figure 6: X-Junction, 20x............................................................................................................................................................................10
Figure 7: X-Junction, 40x............................................................................................................................................................................10
Figure 8: Photomask on SU-8...................................................................................................................................................................10
Figure 9: Finished Mold..............................................................................................................................................................................10
Figure 10: Curing Dish Assembly...........................................................................................................................................................11
Figure 11: Plasma Treatment ..................................................................................................................................................................11
Figure 12: A Complete Device..................................................................................................................................................................11
Figure 13: Micro Hardness Testing.......................................................................................................................................................12
Figure 14: Confocal Microscopy .............................................................................................................................................................12
Figure 15: Preliminary Testing ...............................................................................................................................................................13
Figure 16: High-Speed Videography.....................................................................................................................................................13
Figure 17: Matlab Channel Data Output* ............................................................................................................................................13
Figure 18: JMP Channel Data Output*...................................................................................................................................................13
Figure 19: Table of Statistical Values from JMP...............................................................................................................................14
Figure 20: Device 1, Bottom View..........................................................................................................................................................14
Figure 21: Device 1, Transverse View..................................................................................................................................................14
Figure 22: Device 1, Top View.................................................................................................................................................................15
Figure 23: Device 1, Transverse View..................................................................................................................................................15
Figure 24: Device 2, Top View.................................................................................................................................................................15
Figure 25: Device 2, Transverse View..................................................................................................................................................15
Figure 26: Device 2, Bottom View..........................................................................................................................................................15
Figure 27: Device 2, Transverse View..................................................................................................................................................15
Figure 28: Alginate Viscosity vs Shear Rate ......................................................................................................................................16
Figure 29: Dripping Behavior in Device 4..........................................................................................................................................17
Figure 30: Jetting Behavior in Device 4...............................................................................................................................................18
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 4
MOTIVATION
UVM’s Engineered Biomaterials Research Laboratory (EBRL) has identified that surgical processes
deployed to repair osteochondral defects are largely ineffective. Osteochondral defects (damage to articular
cartilage and the underlying bone), caused either by trauma or chronic inflammation, must be treated to
avoid the development of chronic osteoarthritis and the degeneration of surrounding joint tissues.
Traditionally, surgical procedures take one of three forms: 1) total joint replacement, 2) removal of the
damaged tissue and grafting of tissue-engineered cartilage into the osteochondral lesion, or 3) stimulation of
the body’s natural repair mechanisms by introduction of microfractures in the subchondral bone.
None of these treatments effectively and permanently heal an osteoarthritic joint, and the number of
patients experiencing osteoarthritis continues to increase. The EBRL’s proposed solution is a porous,
implantable or injectable, three-dimensional, biocompatible tissue scaffold, seeded with drugs and/or human
mesenchymal stem cells (hMSCs). To create such a scaffold, biomimetic polymers emulating natural, healthy
osteochondral tissue (cartilage and subchondral bone) is poured over a pre-mold of microspheres. The
microspheres will dissolve once in the body, releasing drugs and/or hMSCs at a controlled rate, and leaving
behind a porous scaffold to support cartilage regrowth. It is crucial that monodisperse microspheres be
produced within a set of relevant size ranges. The EBRL has identified microfluidic flow-focusing devices
(MFFDs) as an effective, low-cost, and high-throughput mechanism for creating homogeneous microspheres.
BACKGROUND
MICROFLUIDICS
The field of microfluidics concerns itself with the properties, applications, and control of fluidic systems
characterized by micro-scale dimensions and volumes. Microfluidics was born in the 1980s from analytical
methods and detection systems designed to operate on tiny amounts of sample material. The application of
these techniques to chemical and biological weapons detection, molecular biology and genomics analysis, and
microelectronics or microelectromechanical systems (MEMS) has since driven the development of the field
(Whitesides 2006). Numerous journals highlighting microfluidic systems and results obtained thereby have
arisen, including Lab-on-a-Chip, Sensors and Actuators, Microfluidics and Nanofluidics, and Analytical
Chemistry. Meanwhile, improvements in available materials, fabrication techniques, and embeddable
subsystems have allowed for the advent of comprehensive “lab-on-a-chip” solutions featuring valves, pumps,
actuators, switches, sensors, dispensers, mixers, filters, separators, and more (Stone et al. 2004).
Microfluidic droplet generators, or MDGs, comprise a specialized class of microfluidic device that
leverages flow-focusing geometry and the fluid properties typically observed in microfluidics to create
emulsions (Anna et al. 2003). While other methods for creating less monodisperse emulsions exist, the
strength of MDGs lies in their ability to produce highly monodisperse microspheres at a broad range of sizes,
while supporting various fabrication techniques and a broad range of features and components. MDGs are
capable of creating oil-in-water and water-in-oil emulsions, as well as double, triple, and even quadruple
emulsions (Abate & Weitz 2009). MDGs retain their capability to produce homogeneous microspheres from
fluids with a broad range of properties, yielding microspheres with diameters of 1 – 500 µm (Nie et al. 2008;
Dendukuri & Doyle 2009; Weibel & Whitesides 2006). Polymer solutions can be dispersed, formed into
special shapes, then crosslinked in situ using either continuous or stop-flow lithography, or chemical
crosslinking (S. Xu et al. 2005; Hu et al. 2012). MDGs are also capable of encapsulating living cells in
polymeric microspheres with high rates of cell viability, a property crucial to the EBRL’s eventual research
goals (Choi et al. 2007; Martinez et al. 2012).
TYPES OF DROPLET GENERATORS
Three main types of droplet generators exist, and are characterized by the geometry they employ for
droplet generation: T-Junction, Co-Flow, and Flow-Focusing. T-Junction droplet generators feature two
orthogonal channels where the dispersed fluid is carried by the incident, truncated channel. As fluids are
pumped through the junction, break-up of the dispersed fluid occurs as the result of combined shear forces
and capillary pressure exerted by the continuous phase (Dendukuri & Doyle 2009).
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 5
Co-flow droplet generators generally feature three coaxial channels, where two cylindrical pipettes with
tips pulled to a desired diameter are enclosed in a third square tube. The fluid to be dispersed is pumped in
through one cylindrical pipette, while the continuous fluid is pumped into the enclosing tube. As the two
immiscible phases are pushed into the empty pipette tip, shear forces exerted by the continuous phase pinch
the dispersed phase into a fine cylinder. Eventually, the surface energy of the thread becomes too great, and
the thread splits into droplets (Baroud et al. 2010; Geschiere et al. 2012). Co-flow droplet generators are
capable of producing multiple emulsions, although the simplest co-flowing geometries feature a capillary tube
ejecting fluid into a second, flowing, immiscible phase to create a single emulsion (Martinez et al. 2012; Fu et
al. 2012).
Flow-focusing droplet generators display greater versatility than co-flowing droplet generators, and have
three or more distinct configurations. These, as shown in Figure 1, include 1) equidimensional continuous,
dispersed, and outflow channels, 2) large continuous and dispersed channels feeding into a small outflow
orifice and channel, and 3) small continuous and dispersed channels feeding into a small orifice, which then
opens to a wider outflow channel (Abate, Poitzsch, et al. 2009a).
All three designs feature co-axial
dispersed and outflow channels, with
the continuous phase supplied on
either side by channels perpendicular
to the dispersed and outflow channels.
While shear forces and capillary
pressure tend to govern droplet
breakup, the exact mechanism of
breakup is highly dependent on the
fluid properties and flow
characteristics (Anna et al. 2003; Fu et
al. 2012). We chose to focus on flow-focusing microfluidic droplet generators, specifically the first type with
equidimensional channels, because 1) they are capable of producing droplets in a wide range of sizes, 2) they
are relatively inexpensive to fabricate, and 3) their operating parameters are well understood and highly
tuneable (McDonald et al. 2000; Cubaud & Mason 2008).
RELEVANT FLUID PARAMETERS
Biphasic microfluidic dynamics in a flow-focusing device are governed by a set of parameters calculable
from the properties of the two working fluids and the dimensions of the device junction. These are 𝜇 𝑐 and 𝜇 𝑑,
the dynamic viscosities, 𝜌𝑐 and 𝜌 𝑑, the densities, 𝑄𝑐 and 𝑄 𝐷, the flow rates, 𝑃𝑐 and 𝑃𝑑, the imposed pressures,
and 𝛾, the interfacial tension between the two fluids. The subscripts c and d denote the continuous and
dispersed phases, respectively. Due to the various fabrication methods most often used, microfluidic channels
are often of uniform height, giving us h, the height of the channels, and 𝑤𝑐 and 𝑤 𝑑, the channel widths. From
these, the mean velocity of a flow can be calculated as 𝑈 = 𝑄 𝐴⁄ (Christopher & Anna 2007). Finally, the ratios
of volumetric flow rates, viscosities, and channel widths will be denoted as 𝜑 = 𝑄 𝑑 𝑄𝑐⁄ , 𝜆 = 𝜇 𝑑 𝜇 𝑐⁄ , and 𝜒 =
𝑤 𝑑 𝑤𝑐⁄ , respectively (Baroud et al. 2010; Christopher & Anna 2007).
From the basic parameters above, a set of dimensionless groups can be calculated to describe fluid
behavior inside the device. The first of these is the Reynolds number, which describes the ratio of inertial
forces to viscous forces acting on a fluid flow, and is often used to predict the charactistics of flow regimes (e.g.
laminar, mixed, turbulent). For closed-pipe flows with rectangular cross-sections, the Reynolds number is
formally defined as 𝑅𝑒 = 𝜌𝐷ℎ 𝑈 𝜇⁄ . The characteristic length is taken as the hydraulic diameter, 𝐷ℎ = 4𝐴 𝑃⁄ ,
where 𝐴 = 𝑤ℎ and 𝑃 = 2𝑤 + 2ℎ for a given channel (White 2010).
The second dimensionless group of concern is the Weber numer, which describes the ratio of inertia to
surface tension. The Weber number is found from 𝑊𝑒 = 𝜌𝑈2
𝑑 𝛾⁄ , where  is the interfacial tension between
the two working fluids, and d is the characteristic diameter of the dispersed phase as it penetrates into the
continuous phase. The third dimensionless group to consider is the capillary number, which descibes the
ratio of viscosity to surface tension, or the ratio of local shear stress to capillary pressure. For a given flow,
Figure 1: Flow-Focusing Configurations
Reproduced from (Abate, Poitzsch, et al. 2009a)
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 6
the capillary number is calculated by 𝐶𝑎 = 𝜇𝑈 𝛾⁄ or 𝐶𝑎 = 𝜇𝑄 𝐴𝛾⁄ (Nunes et al. 2013; White 2010). As inertial
effects are often negligible in microfluidic flows, the capillary number is often used to delineate microfluidic
flow regimes.
The pronounced influence of device geomtery in microfluidics gives rise to slight modifications in the
definitions of relevant dimensionless groups. The Reynolds number is often calculated using channel height
as the characteristic length, such as 𝑅𝑒 = 𝜌𝑄ℎ 𝐴𝜇⁄ or 𝑅𝑒 = 𝜌𝑄 𝜇𝑤⁄ , as for a given device, channel height tends
to be more consistent than width (Anna et al. 2003). Furthermore, the capillary number has been defined as
𝐶𝑎 = 𝜇 𝑐 𝐺𝑤 𝑑 2𝛾⁄ , where 𝐺 = ∆𝑉 ∆𝑍⁄ , ∆𝑉 being the difference in velocity between the flow-focusing junction
and the upstream velocity, and ∆𝑍 being the distance between the end of the dispersed channel to the flow-
focusing orifice (Anna & Mayer 2006).
The language of dimensionless numbers can greatly facilitate comparison between devices and
generalization of results. However, the calculation of relevant fluid parameters, such as interfacial tension,
and the measurement of micro-scale internal channels are challanging tasks on their own. The complete
characterization of a microfluidic device is a decidedly non-trivial process.
FLOW-FOCUSING DYNAMICS
As many as five distinct regimes of flow behavior in equidimensional, type 1 microfluidic flow-focusing
devices have been identified (threading, jetting, dripping, tubing, and displacement); predicting the
transitions between these five is best done using the capillary number (Cubaud & Mason 2008). As flows in
microfluidic devices tend to be strongly laminar, with Reynolds numbers rarely increasing above 𝑅𝑒 = 10,
microsphere production relies on the occurrance of natural instabilites (Stone & Kim 2001; Tang &
Whitesides 2009). The two flow regimes known to produce monodisperse droplets are the jetting and
dripping regimes – in the remaining three flow regimes, no droplets, or polydisperse droplets, are produced.
THE JETTING REGIME
In the jetting regime, shear forces exerted by the continuous phase draw a cylindrical thread of the
dispersed fluid through the flow-focusing junction. Monodisperse droplets form downstream of the junction
due to axisymmetric capillary instabilities that occur in the thread (Eggers 1997; Geschiere et al. 2012).
Jetting behavior occurs for 𝐶𝑎 𝑑 > 0.1. During operation, the capillary thread characteristic of the jetting
regime reaches a critical length 𝐿 𝑐 where droplets break off, such that
𝐿 𝑐 ≈
𝜇 𝑑
𝛾
8
𝜋ℎ𝐶𝑎 𝑐𝑟𝑖𝑡
(
𝑄 𝑑 𝑄𝑐
2
)
0.5
Eq. 1
where 𝐶𝑎 𝑐𝑟𝑖𝑡 represents the threshold capillary number, above which convective instabilities drive
droplet breakup. Furthermore, the diameter of the droplets produced can be predicted by the relation
𝑑
ℎ
≈ 2.192𝜑0.5 Eq. 2
revealing the dimensionless droplet size to be a function of the flow rates of the fluids. This relation holds
regardless of the relative size of the droplets in their channel, and it is noted that droplets smaller than their
enclosing channel are produced when 𝜑 < 𝜑 𝑐𝑟𝑖𝑡, where 𝜑 𝑐𝑟𝑖𝑡 ≈ 0.21 (Cubaud & Mason 2008). Fu et al
propose a more nuanced relation governing droplet size in the jetting regime:
𝑑
𝑤 𝑑
≈ {
1.23𝜑0.41
; 1 < 𝜆 < 12
13.64𝜑1.07
; 𝜆 ≈ 112
Eq. 3
where the second condition 𝜆 ≈ 112 is mentioned in the literature simply as “high viscosity contrast” (Fu
et al. 2012).
THE DRIPPING REGIME
In the dripping regime, a hemispherical cap of the dispersed fluid protrudes from the dispersed channel
until it begins to obstruct the outflow orifice, at which point capillary pressure and shear forces from the
continuous phase pinch the cap of the dispersed phase into a droplet, and the dispersed phase retracts to the
opening of its channel (Nunes et al. 2013; Garstecki et al. 2005). Dripping behavior occurs for 𝐶𝑎 𝑑 < 0.1 and
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 7
𝐶𝑎 𝑐 < 0.1, the lower capillary numbers revealing the greater relative influence of surface tension on the flows.
The diameter of the droplets produced in the dripping regime conform to two distinct sub-domains,
separated by 𝑑 𝑐𝑟𝑖𝑡 ℎ⁄ ≈ 2.5, and described as
𝑑
ℎ
≈
{
2.2 × 10−3
𝛼 𝑐 𝐶𝑎 𝑐
; 𝑑 > 2.5ℎ
1
2(𝛼 𝑐 𝐶𝑎 𝑐)0.17
; 𝑑 < 2.5ℎ
Eq. 4
where 𝛼 𝑐 = 𝑄𝑐 (𝑄𝑐 + 𝑄 𝑑)⁄ (Cubaud & Mason 2008). A second, similar relation for equidimensional cross-
junction is proposed to be
𝑑
𝑤 𝑑
≈
{
0.72𝜑0.14
𝐶𝑎 𝑐
0.19
; 𝑑 ≤ 2.35𝑤 𝑑
0.30𝜑0.23
𝐶𝑎 𝑐
0.42
; 𝑑 > 2.35𝑤 𝑑
Eq. 5
where droplet diameter is non-dimensionalized using the width of the channels, rather than the height
(Fu et al. 2012). Both relations reveal the droplet diameter in the dripping regime to be a function of the ratio
of the flow rates, the geometry of the channels, and the capillary number of either the dispersed or the
continuous flow, despite large size differences in the devices used by the two groups, Cubaud and Mason, and
Fu et al.
FABRICATION METHODS FOR MICROFLUIDIC FLOW-FOCUSING DEVICES
Flow-focusing and T-Junction droplet generators can be fabricated in a variety of methods (Martinez et al.
2012; Tang & Whitesides 2009). The first generation of microfluidic devices were fabricated using techniques
developed for microelectronics, and consisted of photolithography or electron-beam lithography in silicon
and glass. Although these methods produce dimensionally accurate and chemically inert devices, they have
been critiqued for being expensive, inflexible, dependent on specialized equipment, and useful only for planar
geometries – silicon or glass devices are better suited for factory production than lab work (Tang &
Whitesides 2009; Whitesides & Stroock 2001).
Researchers in the field sought to develop faster, cheaper, and more versatile fabrication systems that
retained the dimensional stability and precision of the silicon and glass devices. As of 2008, silicon, silica, or
glass microfluidic devices were still the most used in publications, followed by poly(dimethylsiloxane)
(PDMS), then thermoplastics, such as polymethylmethacrylate (PMMA), polycarbonate (PC), copolymers and
cyclic olefin polymers (COC and COP), among others (Tsao & DeVoe 2008). Various methods exist for
fabricating microfluidic channels from plastics, including hot embossing (Martynova et al. 1997), cold
embossing (J. Xu et al. 2000), injection molding (McCormick et al. 1997), microthermoforming (Giselbrecht et
al. 2006), and CO2 laser machining/IR laser engraving (Romoli et al. 2011; Huang et al. 2006). While
thermoplastics are cheap and easily etched, engraved, or through-cut using a laser cutter, bonding multiple
layers of engineering plastics can become problematic: resins and other glues tend to result in fouling of the
channels, while direct bonding by thermal fusion requires intimate thermal control during the bonding
process, and like bonding via solvent addition, tends to result in poor dimensional stability or channel
collapse. However, welding via laser or ultrasonic energy, especially if enhanced by surface modifications to
the bonded plastics, offer promising alternatives and open the door for high-volume production (Tsao &
DeVoe 2008).
Of all the materials discussed above, PDMS is by far the most flexible, featuring a Young’s modulus of
0.750 MPa < E < 1.0 MPa, and supporting a broad array of geometries and integratable components
(Dendukuri et al. 2007; Unger 2000). Planar PDMS devices are most commonly formed in a process known as
soft-photolithography, whereby 1) a mold is made by hardening a photoresist under light through a
photomask, 2) liquid PDMS and a curing agent are poured over top of the mold and allowed to solidify into a
slab, 3) the slab is peeled from the mold and bonded to a glass slide or a second PDMS sheet, and 4) holes are
cut and tubing is inserted into the new device (Duffy et al. 1998). The simplicity of this method allows for
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 8
rapid prototyping from CAD files (McDonald et al. 2000). The bonding step is crucial and can be performed
reversibly via Van der Waals contact with a second surface, or irreversibly, by activating the PDMS surface
with oxygen plasma and allowing Si-O-Si bonds to form with glass, resulting in a bond capable of
withstanding pressures up to 207-345 kPa (McDonald et al. 2000). In addition to the stamping/casting
process described above, PDMS can also be formed via wet etching, dry etching, or a combination of the two
(Garra et al. 2002; Balakrisnan et al. 2009).
This bonding technique enables the stacking of multiple layers of naturally elastomeric PDMS for the
creation of complex, three-dimensional mixers (Jo et al. 2000), pneumatic/hydraulic “Quake” microvalves
(Wang & Lee 2013), screw and solenoid microvalves (Hulme et al. 2009), pneumatic/hydraulic micropumps
(Unger 2000), prefabricated heaters (Erickson & Li 2004), and heaters fabricated in situ by cooling liquid
solder in microfluidic channels (Tang & Whitesides 2009). The resulting complexity of microfluidic devices is
impressive. Examples include devices that use pneumatic valves to change the size and frequency of droplets
during production (Abate, Romanowsky, et al. 2009b), devices featuring one to five sequential, alternatively-
wetting flow-focusing junctions for single- to quintuple-emulsions (Abate & Weitz 2009), and a flow-focusing
droplet generation and sorting device featuring embedded, computer-controlled laser-detection and a
pressure-actuated valve to separate light from dark droplets at rates of up to 250 Hz with < 0.01% error
(Abate et al. 2010).
While glass may retain the best dimensional stability and chemical inertness and engineering plastics
may be cheaper and faster to fabricate or mass-produce, the moderate cost, low turnaround time, and
incredible flexibility of PDMS microfluidic devices make them optimal for our somewhat open-ended
applications.
OBJECTIVES
Accurate and reliable protocols will be developed for the fabrication, evaluation, and testing of PDMS
microfluidic devices, with the ultimate goal of producing homogeneous microspheres between 1 and 200 µm
in diameter using fluids relevant to the EBRL’s research aims. Using the developed protocols, one or more
microfluidic flow-focusing devices will be fabricated, evaluated, and tested. Data collected will be displayed
analytically, and, if possible, statistically. Its dimensions will be characterized and compared to the intended
design. The device will be filmed under operation using high-speed videography.
METHODS
The bulk of the time spent on this research went into developing and refining the various steps of the
fabrication procedures for PDMS microfluidic devices. Due to the number of steps in the fabrication process,
adequate completion of a step often becomes more important than perfection (for example, the necessity for
spin-coating to produce an even film is crucial, bet producing a film within +/- 1 µm of the intended thickness
is secondary). Early devices suffered due to problems with nearly every step in the fabrication process.
Protocol modifications were sometimes suggested by literature, but groups publishing results obtained with
microfluidic devices tend not to reveal the details of their fabrication methods.
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 9
DEVICE FABRICATION PROCEDURE
OVERVIEW
PDMS microfluidic devices are made in a multi-step
process that increases in complexity with the design intent.
For planar microfluidic devices, a casting/stamping procedure
is used. First, a mold is made. This is accomplished by applying
an even film of photoresist to a substrate (glass or silicon) then
selectively hardening the photoresist with light through a
photomask, sometimes called a transparency. The excess
unhardened photoresist is washed off of the substrate to
create the mold, referenced in Figure 2 as a master. To create
the device, PDMS is then mixed, poured over the mold, and
hardened (note: PDMS curing time varies with composition,
thickness, and thermal properties of the surrounding
materials). Once cured, the PDMS slab is peeled from the mold
and bonded to a microscope slide or a second slab of PDMS to
create microchannels. Finally, if necessary, tubing is fitted to
the new device, allowing for fluids to be pumped through.
MAKING THE MOLD
To make a microfluidic device, a mold must be made by
selectively hardening a photoresist on a glass slide. SU-8 2075
(MicroChem) is a negative photoresist known for its ability to
create features with high aspect ratios. First, a glass slide (75mm x 25mm, Fisher Scientific) is cleaned and
dried, then placed on the vacuum head of a spin coater (Laurell Technologies WS-400BZ-6NPP/LITE). SU-8 is
deposited atop the glass slide then spun to produce a film of uniform thickness. Film thickness varies
inversely with rotational velocity: SU-8 2075 produces a thickness of ~240 µm at 1000 rpm, and ~60 µm at
4000 rpm (MicroChem 2006). This step of the process is highly sensitive to contamination; small dust
particles can result in non-uniform films of SU-8. Optical examination immediately after spin coating reveals
the uniformity of the SU-8 film, as shown in Figures 3 and 4.
Figure 3: Bad Spin-Coating Figure 4: Good Spin-Coating
A non-uniform SU-8 film A uniform SU-8 film
Immediately after spin coating, the coated slide is placed on a hot plate (VWR Int’l. 11301-068) and
undergoes a pre-exposure bake, in which it is heated to 65 ˚C for five minutes, cooled to room temperature,
then heated to 95 ˚C for 10 minutes. This evaporates remaining solvents in the SU-8, and can help smooth
wrinkles that may have appeared during coating. A custom photomask, designed in Solidworks and fabricated
by (PhotomaskPORTAL) is then applied (see Figure 8). Exposing the SU-8 requires between 150-350 𝑚𝐽
𝑐𝑚2 of
near-UV light (IntelliRay 400 W) and correlates to film thickness. For films of this thickness, 4-5 seconds of
exposure hardens the photoresist in the necessary shapes. After curing, a post-exposure bake is performed,
Figure 2: Fabrication Overview
Simplified schematic for PDMS microfluidic device
fabrication, reproduced from (McDonald & Whitesides
2002).
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 10
where the slide, now bearing both hardened and uncured SU-8, is heated to 65 ˚C for two minutes, cooled to
room temperature, then heated to 95 ˚C for 10 minutes. All uncured SU-8 is washed off by submerging the
slide in ethyl lactate and gyrating (VWR Int’l OS-500) for eight minutes, twice.
At this point, the SU-8 molds are evaluated under an optical microscope (Fisher Scientific, 12-561-330) to
ensure that they are free of defects. The critical x-junction at the center of the mold is of particular interest.
Figures 5 through 7 show high quality mold features at varying levels of magnification. The verticality of the
sidewalls and the smoothness of the top of the features are evaluated. The creases, visible in Figures 6 and 7,
are likely due to thermal stresses, but have not been shown to affect the resulting device. A mold that fails to
pass optical inspection is discarded.
Figure 5: X-Junction, 10x Figure 6: X-Junction, 20x Figure 7: X-Junction, 40x
Mold used to make device 1, 10x
magnification
Mold used to make device 1, 20x
magnification
Mold used to make device 1, 40x
magnification
Finally, the finished mold is placed in a vacuum chamber (Cole-Parmer Instrument Co., P-79202-00) with
200 µL (tridecafluoro-1,1,2,2-tetrahydrooctyl)-1-trichlorosilane (Sigma-Aldrich). Inside the vacuum chamber,
the silane is vaporized and evenly coats the glass and SU-8 features, preventing the PDMS from sticking to the
mold. A finished mold is visible in Figure 9.
Figure 8: Photomask on SU-8 Figure 9: Finished Mold
Applying a photomask to a slide coated in uncured SU-8
photoresist
Exposed, rinsed, and silanized, a mold with visibly raised features
reposes in its custom-made curing dish is ready for PDMS
MAKING A DEVICE
Polydimethylsiloxane (PDMS) (Dow Corning, Sylgard 184) is used to create the device. PDMS is a two-
part product. It is thoroughly mixed in a 10:1 ratio of elastomer base and curing agent, then centrifuged at
4000 rpm to accelerate degassing. About 22 mL of PDMS are necessary to make one device. The mold is
placed into a custom curing plate, designed in Solidworks and fabricated in-house, which also contains the
PDMS as it cures on a hot plate. Centrifuged PDMS is poured into the curing plate over the mold, as seen in
Figure 10. To eradicate the bubbles that inevitably form in concave corners of the mold features, the full
curing dish is placed back in the vacuum desiccator, and a vacuum is cyclically pulled and released until all
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 11
bubbles rise to the surface of the PDMS. This done, the curing dish is placed on a hot plate, and cured at any
temperature between 70 ˚C and 150 ˚C (leading to approximate curing times of two and a half hours and half
an hour, respectively). Devices cured at lower temperature show less thermal distorsion and fewer air
bubbles than devices cured at high temperature.
Once cooled, the now hard PDMS slab is gently peeled from its mold and curing dish. The raised features
on the mold are now impressed into the underside of the PDMS slab. With a razor blade, the slab is trimmed
to fit on a new 75mm x 25mm slide. A 1.5mm biopsy punch (Fisher Scientific) is used to create holes for three
0.0625” OD teflon tubes (McMaster-Carr). In order to create closed microfluidic channels capable of
withstanding high pressure without bursting, PDMS and glass are chemically bonded. Air plasma, visible in
Figure 11, is generated using a corona wand (Electro-Technic Products, BD20AC), The plasma alters the
surface chemistry of the new glass slide and the new PDMS slab, allowing the surfaces to bond on contact. The
resulting covalent siloxane (Si—O—Si) bonds that form at the interface are stronger than the PDMS itself
(Duffy et al. 1998). Unfortunately, this treatment also makes the microfluidic channels temporarily
hydrophyllic, which is unfavorable for creating water-in-oil emulsions. Finally, the teflon tubes are inserted,
as is visible in Figure 12, and the device is ready for testing.
Figure 10: Curing Dish Assembly Figure 11: Plasma Treatment
Partially degassed PDMS in a curing dish Activating the surface of a clean glass slide with a corona wand
Figure 12: A Complete Device
A completed, final-generation device ready for testing.
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 12
DEVICE EVALUATION
Microfluidic devices fabricated using the above procedure were evaluated using a variety of methods.
Due to the time-intensive nature of PDMS microfluidic device fabrication, some level of evaluation occurred at
each stage of fabrication to ensure that the resulting device would not be defective. Spin-coated glass slides
are observed using the naked eye to ascertain film flatness, as seen in Figures 2 and 3. Hardened molds are
evaluated for obvious defects using an optical microscope, as seen in Figures 5 through 7. Lastly, the x-
junctions of hardened molds are measured using a micro hardness tester (Beuhler, Micromet II), as seen in
Figure 13. The calibrated vertical bars are moved together or apart, and the gap between the two can be read
off a dial on the apparatus. Channel width in each direction at the x-junction is measured three times
consecutively for statistical power.
Once deemed viable, a mold is silanized and used to create a device. Upon peeling a PDMS slab from the
mold, the slab and mold checked to ensure that no chunks of hardened SU-8 are stuck in the PDMS channels –
any stuck chunks are gently removed. The slab is then bonded to a glass slide as described above. Evaluation
under a microscope is often ineffective, as bonding problems will only present themselves once the device is
pressurized.
To characterize the dimensions of microfluidic channels at higher resolution, the device is pumped full of
a red fluorescent stain (Acti-Stain 555). A confocal microscope (Zeiss, LSM 510 META) is used to obtain a set
of two-dimensional images in the x-y plane with varying focal depth. This set, known as a z-series, is then
reconstructed in specialized software (Volocity) to form a measurable three-dimensional rendering. Sample
results from confocal microscopy are visible in Figure 14. The viscosities of the working fluids were
evaluating using a shear-rate sweep on the EBRL’s rheometer (TA Instruments, AR2000).
Figure 13: Micro Hardness Testing Figure 14: Confocal Microscopy
A mold for a microfluidic device as seen through the micro
hardness tester.
Flourescent channels of the microfluidic device made from the
mold in Figure 12 as seen in confocal microscopy.
DEVICE TESTING
From an understanding of the device dimensions, the properties of the working fluids, and relationships
proposed by previous literature, a range of potentially viable flow rates to test is determined (Nie et al. 2008;
Cubaud & Mason 2008). To ascertain whether or not a device will function, preliminary tests are performed
under an optical microscope (see Figure 15). Once a device is shown to be operational through preliminary
testing, high-speed videography is used to analyze the size, dynamics, and rate of formation of droplets
produced by a device, as shown in Figure 16.
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 13
Figure 15: Preliminary Testing Figure 16: High-Speed Videography
An older revision of a microfluidic device undergoes preliminary
testing under the EBRL’s microscope.
The most recent microfluidic device undergoes testing and filming
using high-speed videography.
Visible in Figure 16, but not in Figure 15, is the pair of syringe pumps (Harvard Apparatus, PHD-2000),
used to feed fluids to microfluidic devices. As seen in Figure 16, high-speed videography is performed with a
high-speed camera (Phantom, v310), which is equipped with an objective microscopic lens (Mitituyo, Plan
Apo 20x) and an in-line fiber optic light source (Edmund Industrial Optics, 21AC). Specialized software is
used to control the high-speed camera (Vision Research, Phantom Camera Control), while more standard
software is used to convert the high-speed videography output into videos (Apple, Quicktime Pro). High-
speed videography data was processed using Matlab routines developed for monopropellant microthruster
research.
RESULTS AND DISCUSSION
MOLD CHARACTERIZATION
The above fabrication protocol was used to fabricate four molds during the fall of 2014. The x-junctions
of these molds were measured in two dimensions as described above using a micro hardness tester, as in
Figure 12, and the resulting data is plotted below. Note: channel height data was obtained via confocal
microscopy on devices resulting from the molds measured using the micro hardness tester.
Figure 17: Matlab Channel Data Output* Figure 18: JMP Channel Data Output*
Figures 17 and 18 show the mean width of the longitudinal and transverse channels at the x-junction of
each of the four molds. Each channel is measured three times. Figure 17 displays the standard deviation of
each set of three measurements, while Figure 18 shows the upper and lower control limits of the data
(𝑈𝐶𝐿 = 80.37 µm and 𝐿𝐶𝐿 = 78.02 µm, respectively). It is noteworthy that the control limits shown in
Figure 18 are artificially small due to small sample size – only three samples comprise each data point in this
graph. Both plots show the global mean channel width, µ = 79.20 µm, very close to the intended value of 80 +/-
5 µm. This tolerance comes from the fabricator of the photomask, who claims 5000 dpi, or 5.08 µm resolution.
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 14
Device Mean
(Width, 1)
Mean
(Width, 2)
Std Dev
(Width, 1)
Std Dev
(Width, 2)
Range
(Width, 1)
Range
(Width, 2)
Mean 2 Minus
Mean 1
1 86.800 89.033 0.819 0.751 1.600 1.500 2.233
2 81.500 84.633 0.608 0.231 1.100 0.400 3.133
3 66.100 67.800 0.954 0.300 1.700 0.600 1.700
4 78.467 79.233 0.681 0.503 1.300 1.000 0.767
Means: 78.217 80.175 0.765 0.446 1.425 0.875 1.958
Figure 19: Table of Statistical Values from JMP*
Figure 19 supports the above graphs with numerical data. All devices feature longitudinally oriented
channels wider than transversally oriented channels by 1.968 µm, on average, but the difference in channel
width (“Mean 2 Minus Mean 1” in Figure 19) does not correlate with the magnitude of the channel widths.
This value is within the tolerance of the photomask, and as it is relatively consistent across all devices, it can
be attributed to error in the fabrication of the device. The low standard deviations observed for set of channel
measurements show relatively precise data collection.
DEVICE CHARACTERIZATION
From the confocal microscopy data obtained of Devices 1 and 2, UVM’s Microscopy Imaging center
returned still images, three-dimensional reconstructions and fly-though videos, and partial dimensions of
Devices 1 and 2. Still images are included below in Figures 20 through 27.
Figure 20: Device 1, Bottom View
Figure 21: Device 1, Transverse View
* All values in µm
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 15
Figure 22: Device 1, Top View Figure 23: Device 1, Transverse View
Figure 24: Device 2, Top View Figure 25: Device 2, Transverse View
Figure 26: Device 2, Bottom View Figure 27: Device 2, Transverse View
The images obtained via confocal microscopy reveal microfluidic channels of mixed quality. It is
immediately visible that the sidewalls of channels in both devices are not vertical. The effect is not visible
only in the wide sections of the microfluidic channels, but also in the critical, choked x-junction. This could be
due to the scattering of UV light as the photoresist is hardened, but it is more likely that the tapering be the
result of deformation as the PDMS slab is “rolled” onto its glass slide after plasma treatment. These problems
can be solved by ensuring that the photomask is pressed tightly to the surface of the SU-8 photoresist before
hardening, and by deforming the PDMS slab less as it is affixed to the glass slide, respectively.
As can be seen in the above images, the channels of Device 1 are higher than those of Device 2. The height
of Device 1’s channels at the x-junction was estimated by the MIC at 71.775 µm, while the height of Device 2’s
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 16
channels was at the x-junction was extimated at 45.675 µm. It is unclear exactly why this difference occurred,
as the two molds were created using identical procedures. As mentioned before, minor impurities can have
dramatic impacts on the uniformity of the photoresist film, thus, to help eradicate this inconsistency, slides
should be treated with extreme care from initial cleaning to after the photoresist is hardened.
VIDEOGRAPHY DATA
A microfluidic flow-focusing device, fabricated using the above methods from mold 4 (see Figures 17
through 19) was tested using the setup shown in Figure 16. 2% sodium-alginate in deionized water dyed
with Trypan blue (Sigma-Aldrich, CAS: 72-57-1) was pumped into the device as the dispersed phase, while
light mineral oil (Sigma-Aldrich, CAS: 8042-47-5) was pumped into the device as the continuous phase. A
typical viscosity profile for 2wt% sodium-alginate is
included in Figure 28. The Na-alginate solution
exhibits slight shear-thinning behavior, decreasing
in viscosity from 0.7 to 0.3 Pa*s over the range of
shear rates tested. The light mineral oil is
considered Newtonian with a viscosity of .03 Pa*s
(Sigma-Aldrich 2011). Code used to produce Figure
28 can be found in the appendix.
During videography testing, data was recorded
at 2000 frames per second, and saved either as
individual .jpg files, or as .mov files for ease of use.
The test protocol described in Figure 16 was
applied directly, with two syringe pumps delivering
one fluid each at finely controllable flow rates. To
finely tune the position of the camera, the device
was placed on a stage that can be adjusted in three
dimensions.
Device 4, visible in Figures 12 and 16, displayed three of the five behaviors seen in microfluidic flow-
focusing devices: tubing, dripping, and jetting. Although tubing is a curious behavior to observe, it is
secondary to the research objectives and was not recorded. Dripping was the most commonly observed
behavior, occurring at lower total flow rates, but at a broad range of flow-rate ratios. Jetting behavior was
also achieved, despite its relative difficulty.
DRIPPING BEHAVIOR
The following sequence of still images showcases the dripping behavior of Device 4. At 2000 fps, each
frame represents a 0.5 ms advancement in time from the previous. Oil enters through the left and right
channels, while 2wt% Na-Alginate enters through the top channel and protrudes into the x-junction. The net
direction of the flow is downwards.
Figure 28: Alginate Viscosity vs Shear Rate
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 17
D.1 D.2 D.3 D.4 D.5 D.6
D.7 D.8 D.9 D.10 D.11 D.12
D.13 D.14 D.15 D.16 D.17 D.18
D.19 D.20 D.21 D.22 D.23 D.24
D.25 D.26
Figure 29: Dripping Behavior in Device 4
Over the course of the 26 frames above, one droplet of 2wt% Na-Alginate is produced. Roughly 12.5 ms
transpire; during this period of steady state operation, droplets were produced at about 80 Hz. The droplet
breakup dynamics characteristic of the dripping regime are showed step-by step in this sequence: the cycle
begins with the dispersed phase protruding out into the junction from the dispersed channel. As it blocks
more and more of the outflow orifice, capillary pressure and shear force from the impinging oil pinch the
dispersed phase until a new droplet breaks off. Although the new droplet in D.26 shares its position with the
new droplet in D.1, creating the impression that a whole cycle has occurred, care must be taken to
comprehensively evaluate the flow. A glance downstream at the droplets populating the efflux channel in
D.26 shows that they are on opposite sides of a hypothetical centerline of the device. Thus, it is more correct
to conclude that over 25 ms two droplets are produced. Using the width of the x-junction, found to be
measure roughly 79 µm, the diameter of the droplets produced can be estimated at roughly 70 µm.
JETTING BEHAVIOR
The following sequence of images shows Device 4 displaying jetting behavior. The video data was
recorded at 2000 fps, but in this sequence, only half the frames are displayed, yielding an effective frame rate
of 1000 fps and 1 ms time advancement between frames. The orientation of the device is the same as in the
previous sequence of images.
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 18
J.1 J.3 J.5 J.7 J.9 J.11
J.13 J.15 J.17 J.19 J.21 J.23
J.25 J.27 J.29 J.31 J.33 J.35
J.37 J.39
Figure 30: Jetting Behavior in Device 4
In this sequence, one microsphere is produced over the course of 38 ms, giving a frequency of
approximately 26.3 Hz. Classing dripping regime droplet breakup dynamics are showcased in this sequence.
In contrast with the previous segment, droplet breakup occurs downstream of the x-junction. Increased shear
forces pull the dispersed phase into a capillary thread as it passes through the x-junction. Plateau-Rayleigh
instabilities appear as axisymmetric ripples in the dispersed phase thread in the otherwise highly regular
flow. Eventually, as predicted, the surface energy becomes too high, and the capillary thread breaks off
another microspheres.
SUMMARY
Over the course of this research, an understanding of the fluid mechanics driving microfluidic droplet
generation through flow-focusing was obtained through a study of extant literature. Techniques for the
fabrication of PDMS microfluidic devices were developed and refined, then codified as procedures for
laboratory use. Various methods for characterizing the dimensions of a PDMS microfluidic device were
investigated and used to inform design decisions and support modifications to fabrication procedures.
Protocols for testing microfluidic devices were created, and the performance of microfluidic flow-focusing
devices was demonstrated through high-speed videography.
CONCLUSIONS
The groundwork laid by this research was sufficient to produce a PDMS microfluidic flow-focusing device
capable of generating microspheres of sizes useful to the Engineered Biomaterials Research Laboratory’s
research aims.
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 19
FUTURE WORK
While previous improvements in procedures could be made based on largely subjective assessments,
statistical analysis is required to assess the most important next steps forward. Thus, the first step to take is
to make at least 30 more devices using the above procedures. Once the consistency of the fabrication methods
is assessed quantitatively (and not qualitatively or with too few samples) devices with different dimensions
should be fabricated, evaluated, and tested in order to begin making microspheres of smaller size. This done,
the EBRL will be able to apply this research to its various projects requiring microspheres, including
photocrosslinked alginate microspheres, osteochondral repair systems, and pleural sealant patches.
ACKNOWLEDGEMENTS
I would like to thank Dr. Oldinski, my advisor and PI, for her support and mentorship. I owe immense
thanks to committee members Dr. Hitt and Dr. Sansoz for generously offering their time, techniques, advice,
and equipment. I thank Dr. McDevitt for his high-speed videography wisdom. I would also like to give thanks
to the many members of the EBRL who have helped out at various points along the way, including Patrick
Charron, Spencer Fenn, Meredith Koch, Tianxin Miao, Alex Poniz, and Emily Miller. Thanks go to Nicole
Bishop and Nicole Bouffard at the UVM Microscopy Imaging Center for their help with confocal microscopy, to
Marc “Stump” Soldini, from whom I inherited this project, to Danielle Dawson for lending a hand with
statistical analysis, and to Floyd Vilmont of UVM’s Machine Shop for his help in metal fabrication. A special
thank-you goes to Aly Johnson-Kurts, for her patience with nerdy engineering jargon and her keen eye for
editing. This research was funded in part by UVM’s Office of Undergraduate Research.
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 20
APPENDIX
Relevant video data not included will be shown and distributed during defense.
MATLAB CODE
CHANNEL MEASUREMENT ANALYSIS AND PLOTTING
% Device dimensions
clc;clear all;clf;
dims = [85.9 89.0 81.8 84.5 66.6 67.5 77.7 78.7;
87.5 88.3 80.8 84.9 65.0 67.8 79.0 79.3;
87.0 89.8 81.9 84.5 66.7 68.1 78.7 79.7];
molds = {'Mold 1, Tr' 'Mold 1, Lo' 'Mold 2, Tr' 'Mold 2, Lo' 'Mold 3, Tr' 'Mold 3, Lo' 'Mold 4,
Tr' 'Mold 4, Lo'};
means = [mean(dims(:,1)) mean(dims(:,2)) mean(dims(:,3)) mean(dims(:,4)) mean(dims(:,5))
mean(dims(:,6)) mean(dims(:,7)) mean(dims(:,8))];
specDifs = [abs(means(1) - means(2)) abs(means(3) - means(4)) abs(means(5) - means(6))
abs(means(7) - means(8))];
meanDifs = mean(specDifs);
stds = [std(dims(:,1)) std(dims(:,2)) std(dims(:,3)) std(dims(:,4)) std(dims(:,5)) std(dims(:,6))
std(dims(:,7)) std(dims(:,8))];
bar(means)
hold on
errorbar(means,stds,'r.')
plot([0 9],[mean(means) mean(means)],'g--')
set(gca,'XTickLabel',molds)
str1 = 'Global Mean: ';
str2 = num2str(mean(means));
str3 = 'mu';
str4 = 'm';
text(5,82,strcat(str1,str2,str3,str4))
xlabel('Molds 1-4, Widths 1 and 2')
ylabel('Channel Width, um')
legend('Mean Channel Widths','Standard Deviation','Global Mean','Location','SouthEast')
title('MFFD x-junction Dimensions')
print(gcf,'ChannelDims','-r1000','-djpeg')
VIDEO ANALYSIS AND PLOTTING
format short
FrameRate = 20000;
MaxFrame = 2461;
ImageData = cell(1,MaxFrame);
for FrameNumber=1:MaxFrame
if FrameNumber<10
FrameName = ['000' num2str(FrameNumber) '.jpg'];
elseif FrameNumber<100
FrameName = ['00' num2str(FrameNumber) '.jpg'];
elseif FrameNumber<1000
FrameName = ['0' num2str(FrameNumber) '.jpg'];
else
FrameName = [num2str(FrameNumber) '.jpg'];
end
ImageData{FrameNumber} = imread(FrameName);
[ nrow, ncol, ndim ] = size(ImageData);
ImageData{FrameNumber} = ImageData{FrameNumber}(24:48,32:793,:);
%The numbers help to zoom in on the dimensions of the channel
background = imopen(ImageData{FrameNumber},strel('disk',15));
ImageData{FrameNumber} = ImageData{FrameNumber} - background;
ImageData{FrameNumber} = imadjust(ImageData{FrameNumber});
level = graythresh(ImageData{FrameNumber});
bw = im2bw(ImageData{FrameNumber},level);
bw = bwareaopen(bw, 50);
end
PixData = ImageData{FrameNumber}(:,:,1);
PixData = mean(PixData,1);
PixData = double( double(PixData) - mean(PixData));
% Plot the pixel intensity data
figure;
plot(PixData);
% This just shows the average peaks and valleys that the FFT is
% based upon. If it's not giving you roughly the same profile as
% you're seeing in your images, then the image thresholding may not
% be working properly.
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 21
% Compute and plot power spectrum for intensity sequence
NPixData = length(PixData);
MyFFT= fft(PixData); % compute FFT
MyPow = MyFFT.*conj(MyFFT); % compute power spectral density
MyPow = MyPow/max(MyPow); % normalize spectral data
freqrange = linspace(0,0.5,round(NPixData/2))*FrameRate;
figure;
semilogx(freqrange,MyPow(1:NPixData/2));
xlabel('Frequency(Hz)')
ylabel('Normalized Spectral Density')
fid = fopen('pixdata.txt', 'w');
for f = 1:NPixData
fprintf(fid, '%6.2fn', PixData(f));
end
fclose(fid);
fid1 = fopen('powdata.txt', 'w');
for f = 1:NPixData/2
fprintf(fid1, '%6.2fn', MyPow(f));
end
fclose(fid1);
VISCOSITY PLOTTING (EXAMPLE)
clc;clear all;
filename = '2wt% AAMA in 1xPBS visco 1-0007f exp.txt';
fid = fopen(filename);
data = textscan(fid,'-%f %f %f %f %f %f %f %f;','HeaderLines',7)
normalForce = data{1};
shearRate = data{2};
time = data{3};
velocity = data{4};
viscosity = data{5};
handie = figure;
plot(shearRate,viscosity,'bo')
title('2wt% AAMA Viscosity vs. Shear Rate')
ylabel('Viscosity (Pa*s)')
xlabel('Shear Rate (1/s)')
axis([0 1.1*max(shearRate) 0 1.1*max(viscosity)])
filename = filename(1:end-4);
filename = strcat(filename,'.jpg');
print(handie,filename,'-r800','-djpeg');
BIBLIOGRAPHY
Abate, A.R. & Weitz, D.A., 2009. High-Order Multiple Emulsions Formed in Poly(dimethylsiloxane)
Microfluidics. Small, 5(18), pp.2030–2032.
Abate, A.R., Agresti, J.J. & Weitz, D.A., 2010. Microfluidic sorting with high-speed single-layer membrane
valves. Applied Physics Letters, 96(20), p.203509.
Abate, A.R., Poitzsch, A., et al., 2009a. Impact of inlet channel geometry on microfluidic drop formation.
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 22
Physical Review E, 80(2), p.026310.
Abate, A.R., Romanowsky, M.B., et al., 2009b. Valve-based flow focusing for drop formation. Applied Physics
Letters, 94(2), p.023503.
Anna, S.L. & Mayer, H.C., 2006. Microscale tipstreaming in a microfluidic flow focusing device. Physics of Fluids,
18(12), p.121512.
Anna, S.L., Bontoux, N. & Stone, H.A., 2003. Formation of dispersions using “flow focusing” in microchannels.
Applied Physics Letters, 82(3), pp.364–366.
Balakrisnan, B., Patil, S. & Smela, E., 2009. Patterning PDMS using a combination of wet and dry etching.
Journal of Micromechanics and Microengineering, 19(4), p.047002.
Baroud, C.N., Gallaire, F. & Dangla, R., 2010. Dynamics of microfluidic droplets. Lab on a Chip, 10(16),
pp.2032–2045.
Choi, C.-H. et al., 2007. Generation of monodisperse alginate microbeads and in situ encapsulation of cell in
microfluidic device. Biomedical Microdevices, 9(6), pp.855–862.
Christopher, G.F. & Anna, S.L., 2007. Microfluidic methods for generating continuous droplet streams. Journal
of Physics D: Applied Physics, 40(19), pp.R319–R336.
Cubaud, T. & Mason, T.G., 2008. Capillary threads and viscous droplets in square microchannels. Physics of
Fluids, 20(5), p.053302.
Dendukuri, D. & Doyle, P.S., 2009. The Synthesis and Assembly of Polymeric Microparticles Using
Microfluidics. Advanced Materials, 21(41), pp.4071–4086.
Dendukuri, D. et al., 2007. Stop-flow lithography in a microfluidic device. Lab on a Chip, 7(7), p.818.
Duffy, D.C. et al., 1998. Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane). Analytical
Chemistry, 70(23), pp.4974–4984.
Eggers, J., 1997. Nonlinear dynamics and breakup of free-surface flows. Reviews of Modern Physics, 69(3),
pp.865–929.
Erickson, D. & Li, D., 2004. Integrated microfluidic devices. Analytica Chimica Acta, 507(1), pp.11–26.
Fu, T. et al., 2012. Droplet formation and breakup dynamics in microfluidic flow-focusing devices: From
dripping to jetting. Chemical Engineering Science, 84(C), pp.207–217.
Garra, J. et al., 2002. Dry etching of polydimethylsiloxane for microfluidic systems. Journal of Vacuum Science
& Technology A: Vacuum, Surfaces, and Films, 20(3), p.975.
Garstecki, P., Stone, H.A. & Whitesides, G.M., 2005. Mechanism for Flow-Rate Controlled Breakup in Confined
Geometries: A Route to Monodisperse Emulsions. Physical Review Letters, 94(16), pp.1–4.
Geschiere, S.D. et al., 2012. Slow growth of the Rayleigh-Plateau instability in aqueous two phase systems.
Biomicrofluidics, 6(2), p.022007.
Giselbrecht, S. et al., 2006. 3D tissue culture substrates produced by microthermoforming of pre-processed
polymer films. Biomedical Microdevices, 8(3), pp.191–199.
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 23
Hu, Y. et al., 2012. Shape controllable microgel particles prepared by microfluidic combining external ionic
crosslinking. Biomicrofluidics, 6(2).
Huang, K.-S., Lai, T.-H. & Lin, Y.-C., 2006. Manipulating the generation of Ca-alginate microspheres using
microfluidic channels as a carrier of gold nanoparticles. Lab on a Chip, 6(7), pp.954–957.
Hulme, E.S., Shevkoplyas, S.S. & Whitesides, G.M., 2009. Incorporation of prefabricated screw, pneumatic, and
solenoid valves into microfluidic devices. Lab on a Chip, 9(1), p.79.
Jo, B.-H. et al., 2000. Three-Dimensional Micro-Channel Fabrication inPolydimethylsiloxane (PDMS)
Elastomer. Journal of Microelectromechanical Systems, 9(1), pp.76–81.
Martinez, C.J. et al., 2012. A Microfluidic Approach to Encapsulate Living Cells in Uniform Alginate Hydrogel
Microparticles. Macromolecular Bioscience, 12(7), pp.946–951.
Martynova, L. et al., 1997. Fabrication of Plastic Microfluid Channels by Imprinting Methods. Analytical
Chemistry, 69(23), pp.4783–4789.
McCormick, R.M. et al., 1997. Microchannel Electrophoretic Separations of DNA in Injection-Molded Plastic
Substrates. Analytical Chemistry, 69(14), pp.2626–2630.
McDonald, J.C. & Whitesides, G.M., 2002. Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic
Devices. Accounts of Chemical Research, 35(7), pp.491–499.
McDonald, J.C. et al., 2000. Fabrication of microfluidic systems in poly(dimethylsiloxane). Electrophoresis,
27(1), pp.27–40.
MicroChem, 2006. SU-8 2000 Permanent Epoxy Negative Photoresist. pp.1–5.
Nie, Z. et al., 2008. Emulsification in a microfluidic flow-focusing device: effect of the viscosities of the liquids.
Microfluidics and Nanofluidics, 5(5), pp.585–594.
Nunes, J.K. et al., 2013. Dripping and jetting in microfluidic multiphase flows applied to particle and fibre
synthesis. Journal of Physics D: Applied Physics, 46(11).
Romoli, L., Tantussi, G. & Dini, G., 2011. Optics and Lasers in Engineering. Optics and Lasers in Engineering,
49(3), pp.419–427.
Sigma-Aldrich, 2011. Product Specification: Mineral Oil - Light Oil (neat), BioReagent. pp.1–1.
Stone, H.A. & Kim, S., 2001. Microfluidics: Basic Issues, Applications, and Challenges. AIChE Journal, 47, pp.1–5.
Stone, H.A., Stroock, A.D. & Ajdari, A., 2004. Engineering Flows in Small Devices. Annual Review of Fluid
Mechanics, 36(1), pp.381–411.
Tang, S.K.Y. & Whitesides, G.M., 2009. Basic Microfluidic and Soft Lithographic Techniques. Optofluidics:
Fundamentals, Devices, and Applications, pp.7–31.
Tsao, C.-W. & DeVoe, D.L., 2008. Bonding of thermoplastic polymer microfluidics. Microfluidics and
Nanofluidics, 6(1), pp.1–16.
Unger, M.A., 2000. Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography. Science,
288(5463), pp.113–116.
Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 24
Wang, J.-H. & Lee, G.-B., 2013. Formation of Tunable, Emulsion Micro-Droplets Utilizing Flow-Focusing
Channels and a Normally-Closed Micro-Valve. Micromachines, 4(3), pp.306–320.
Weibel, D.B. & Whitesides, G.M., 2006. Applications of Microfluidics in Chemical Biology. Current Opinion in
Chemical Biology, 10(6), pp.584–591.
White, F.M., 2010. Fluid Mechanics 7 ed., New York: McGraw-HIll.
Whitesides, G.M., 2006. The origins and the future of microfluidics. Nature, 442(7101), pp.368–373.
Whitesides, G.M. & Stroock, A.D., 2001. Flexible Methods for Microfluidics. Physics Today, pp.1–7.
Xu, J. et al., 2000. Room-Temperature Imprinting Method for Plastic Microchannel Fabrication. Analytical
Chemistry, 72(8), pp.1930–1933.
Xu, S. et al., 2005. Generation of Monodisperse Particles by Using Microfluidics: Control over Size, Shape, and
Composition. Angewandte Chemie International Edition, 44(5), pp.724–728.

More Related Content

What's hot

Organ and bio 3D printing
Organ and bio 3D printingOrgan and bio 3D printing
Organ and bio 3D printing
Carsten Engel
 
Fusion trifold
Fusion trifoldFusion trifold
Fusion trifold
Eyal Dolev
 

What's hot (8)

Case study 2 - Tissue Engineering Scaffold
Case study 2  - Tissue Engineering ScaffoldCase study 2  - Tissue Engineering Scaffold
Case study 2 - Tissue Engineering Scaffold
 
Seminar
SeminarSeminar
Seminar
 
New generations of drug eluting
New generations of drug elutingNew generations of drug eluting
New generations of drug eluting
 
Organ and bio 3D printing
Organ and bio 3D printingOrgan and bio 3D printing
Organ and bio 3D printing
 
Fusion trifold
Fusion trifoldFusion trifold
Fusion trifold
 
3D bioprinting
3D bioprinting3D bioprinting
3D bioprinting
 
Healthcare and additive manufacturing
Healthcare and additive manufacturingHealthcare and additive manufacturing
Healthcare and additive manufacturing
 
Introduction to 3D Bio-printing
Introduction to 3D Bio-printingIntroduction to 3D Bio-printing
Introduction to 3D Bio-printing
 

Viewers also liked

Colt sdn-strategy-telesemana-diciembre-2013-javier-benitez-colt-final
Colt sdn-strategy-telesemana-diciembre-2013-javier-benitez-colt-finalColt sdn-strategy-telesemana-diciembre-2013-javier-benitez-colt-final
Colt sdn-strategy-telesemana-diciembre-2013-javier-benitez-colt-final
Rafael Junquera
 
Surat yasin-not-perfect
Surat yasin-not-perfectSurat yasin-not-perfect
Surat yasin-not-perfect
nyongkoh
 

Viewers also liked (18)

Comunidad sorda
Comunidad sordaComunidad sorda
Comunidad sorda
 
Description explanation 1
Description explanation 1Description explanation 1
Description explanation 1
 
Colt sdn-strategy-telesemana-diciembre-2013-javier-benitez-colt-final
Colt sdn-strategy-telesemana-diciembre-2013-javier-benitez-colt-finalColt sdn-strategy-telesemana-diciembre-2013-javier-benitez-colt-final
Colt sdn-strategy-telesemana-diciembre-2013-javier-benitez-colt-final
 
SLG Recession Alert Memo
SLG Recession Alert MemoSLG Recession Alert Memo
SLG Recession Alert Memo
 
LSSYB
LSSYBLSSYB
LSSYB
 
Increase the impact of your materials with visual design
Increase the impact of your materials with visual designIncrease the impact of your materials with visual design
Increase the impact of your materials with visual design
 
378 Блинова Дарья тезисы
378 Блинова Дарья тезисы378 Блинова Дарья тезисы
378 Блинова Дарья тезисы
 
Capabilities_TLIT
Capabilities_TLITCapabilities_TLIT
Capabilities_TLIT
 
LCerrillo-Resume2015
LCerrillo-Resume2015LCerrillo-Resume2015
LCerrillo-Resume2015
 
Assess, inform, educate
Assess, inform, educateAssess, inform, educate
Assess, inform, educate
 
Agi tunisia local_governance_model
Agi tunisia local_governance_modelAgi tunisia local_governance_model
Agi tunisia local_governance_model
 
CV Chandrajit Samanta
CV Chandrajit SamantaCV Chandrajit Samanta
CV Chandrajit Samanta
 
How to survive exams - An E-concept guide
How to survive exams - An E-concept guideHow to survive exams - An E-concept guide
How to survive exams - An E-concept guide
 
Surat yasin-not-perfect
Surat yasin-not-perfectSurat yasin-not-perfect
Surat yasin-not-perfect
 
Anticoagulantes y antiagregantes
Anticoagulantes y antiagregantes Anticoagulantes y antiagregantes
Anticoagulantes y antiagregantes
 
Mapa conceptual de Redaccion Juridica
Mapa conceptual de Redaccion JuridicaMapa conceptual de Redaccion Juridica
Mapa conceptual de Redaccion Juridica
 
3 hexil-2-pentilpenta-1,3-dieno
3 hexil-2-pentilpenta-1,3-dieno3 hexil-2-pentilpenta-1,3-dieno
3 hexil-2-pentilpenta-1,3-dieno
 
fraret Sebastien
fraret Sebastienfraret Sebastien
fraret Sebastien
 

Similar to UGHT R vF

Organs on a chip
Organs on a chipOrgans on a chip
Organs on a chip
rashmiakula
 
Multiorgan microdevices
Multiorgan microdevicesMultiorgan microdevices
Multiorgan microdevices
Ashish Rajput
 
recent advances in prosthodontics/dental lab technology courses by Indian den...
recent advances in prosthodontics/dental lab technology courses by Indian den...recent advances in prosthodontics/dental lab technology courses by Indian den...
recent advances in prosthodontics/dental lab technology courses by Indian den...
Indian dental academy
 
3 d biomatrix-white-paper-3d-cell-culture-101
3 d biomatrix-white-paper-3d-cell-culture-1013 d biomatrix-white-paper-3d-cell-culture-101
3 d biomatrix-white-paper-3d-cell-culture-101
ratna azizah
 
Characterization of effective mechanical strength of chitosan porous tissue s...
Characterization of effective mechanical strength of chitosan porous tissue s...Characterization of effective mechanical strength of chitosan porous tissue s...
Characterization of effective mechanical strength of chitosan porous tissue s...
ijbesjournal
 
Advances and Innovations and Impediments in Tissue Engineering and Regenerati...
Advances and Innovations and Impediments in Tissue Engineering and Regenerati...Advances and Innovations and Impediments in Tissue Engineering and Regenerati...
Advances and Innovations and Impediments in Tissue Engineering and Regenerati...
CrimsonpublishersITERM
 

Similar to UGHT R vF (20)

Organs on a chip
Organs on a chipOrgans on a chip
Organs on a chip
 
organ_on_chip seminar topic for students,
organ_on_chip seminar topic for students,organ_on_chip seminar topic for students,
organ_on_chip seminar topic for students,
 
3D-Bioprinting coming of age-from cells to organs
3D-Bioprinting coming of age-from cells to organs3D-Bioprinting coming of age-from cells to organs
3D-Bioprinting coming of age-from cells to organs
 
Andrew_Mac_Guinness_12042854
Andrew_Mac_Guinness_12042854Andrew_Mac_Guinness_12042854
Andrew_Mac_Guinness_12042854
 
Microfluidics Paper
Microfluidics PaperMicrofluidics Paper
Microfluidics Paper
 
Microfluidics Presentation
Microfluidics PresentationMicrofluidics Presentation
Microfluidics Presentation
 
Bioreactors in tissue engineering
Bioreactors in tissue engineeringBioreactors in tissue engineering
Bioreactors in tissue engineering
 
Orthopaedic tissue engineering
Orthopaedic tissue engineeringOrthopaedic tissue engineering
Orthopaedic tissue engineering
 
Poster - BIOMIMESYS® 3D hydroscaffold a matricial microenvironment for physio...
Poster - BIOMIMESYS® 3D hydroscaffold a matricial microenvironment for physio...Poster - BIOMIMESYS® 3D hydroscaffold a matricial microenvironment for physio...
Poster - BIOMIMESYS® 3D hydroscaffold a matricial microenvironment for physio...
 
SMi Group's 3d Cell Culture 2019 conference
SMi Group's 3d Cell Culture 2019 conferenceSMi Group's 3d Cell Culture 2019 conference
SMi Group's 3d Cell Culture 2019 conference
 
Multiorgan microdevices
Multiorgan microdevicesMultiorgan microdevices
Multiorgan microdevices
 
recent advances in prosthodontics/dental lab technology courses by Indian den...
recent advances in prosthodontics/dental lab technology courses by Indian den...recent advances in prosthodontics/dental lab technology courses by Indian den...
recent advances in prosthodontics/dental lab technology courses by Indian den...
 
Recent advances in prosthodontics / crown & bridge courses by indian dental a...
Recent advances in prosthodontics / crown & bridge courses by indian dental a...Recent advances in prosthodontics / crown & bridge courses by indian dental a...
Recent advances in prosthodontics / crown & bridge courses by indian dental a...
 
From 3D cell culture to organs-on-chips.pdf
From 3D cell culture to organs-on-chips.pdfFrom 3D cell culture to organs-on-chips.pdf
From 3D cell culture to organs-on-chips.pdf
 
3 d biomatrix-white-paper-3d-cell-culture-101
3 d biomatrix-white-paper-3d-cell-culture-1013 d biomatrix-white-paper-3d-cell-culture-101
3 d biomatrix-white-paper-3d-cell-culture-101
 
Autologous Mesenchymal Stem Cells in Orthopaedics
Autologous Mesenchymal Stem Cells in OrthopaedicsAutologous Mesenchymal Stem Cells in Orthopaedics
Autologous Mesenchymal Stem Cells in Orthopaedics
 
Mechanical simulations in tissue engineering
Mechanical simulations in tissue engineeringMechanical simulations in tissue engineering
Mechanical simulations in tissue engineering
 
Characterization of effective mechanical strength of chitosan porous tissue s...
Characterization of effective mechanical strength of chitosan porous tissue s...Characterization of effective mechanical strength of chitosan porous tissue s...
Characterization of effective mechanical strength of chitosan porous tissue s...
 
Microfluidics and organ on-a-chip
Microfluidics and organ on-a-chipMicrofluidics and organ on-a-chip
Microfluidics and organ on-a-chip
 
Advances and Innovations and Impediments in Tissue Engineering and Regenerati...
Advances and Innovations and Impediments in Tissue Engineering and Regenerati...Advances and Innovations and Impediments in Tissue Engineering and Regenerati...
Advances and Innovations and Impediments in Tissue Engineering and Regenerati...
 

UGHT R vF

  • 1. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 1 DESIGN AND FABRICATION OF FLOW-FOCUSING DEVICES FOR TISSUE ENGINEERING APPLICATIONS SAMUEL HOTALING ADVISOR: DR. RACHAEL OLDINSKI ABSTRACT While the lifespan of humans has increased, the durability of cartilage has not, leading to increasing rates of arthritis in aging humans. As both natural and surgical methods for repairing osteochondral defects tend to fall short, UVM’s Engineered Biomaterials Research Laboratory (EBRL) is working towards a solution where biomimetic, polymeric, and porous engineered tissue scaffolds are seeded with drugs and human mesenchymal stem cells (hMSCs). The seeded scaffold is then implanted or injected into the patient’s osteochondral defect, where the hMSCs differentiate and grow a new cartilaginous extracellular matrix to heal the defect as the artificial scaffold breaks down. Microspheres in three distinct size ranges are required to create pores and embed drugs and cells in the scaffold. In order to produce these microspheres, we turn to the field of microfluidics, which examines fluid interactions at micro-scale geometries and flow rates. A microfluidic flow-focusing device (MFFD) leverages the low Reynolds numbers and pronounced effects of surface tension in such flows to create highly monodisperse droplets of one fluid in a second. This project investigates the design and fabrication of MFFDs for the production of homogeneous microspheres. A MFFD must be consistently reproducible, readily characterized, and easy to test and use. MFFDs show great potential to successfully play a role in the EBRL’s investigation of engineered tissue scaffolds.
  • 2. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 2 TABLE OF CONTENTS Abstract....................................................................................................................................................................................................... 1 Table of Contents.................................................................................................................................................................................... 2 Table of Figures....................................................................................................................................................................................... 3 Motivation.................................................................................................................................................................................................. 4 Background............................................................................................................................................................................................... 4 Microfluidics....................................................................................................................................................................................... 4 Types of Droplet Generators ....................................................................................................................................................... 4 Relevant Fluid Parameters........................................................................................................................................................... 5 Flow-Focusing Dynamics .............................................................................................................................................................. 6 The Jetting Regime..................................................................................................................................................................... 6 The Dripping Regime................................................................................................................................................................ 6 Fabrication Methods for Microfluidic Flow-Focusing Devices..................................................................................... 7 Objectives................................................................................................................................................................................................... 8 Methods ...................................................................................................................................................................................................... 8 Device Fabrication Procedure..................................................................................................................................................... 9 Overview......................................................................................................................................................................................... 9 Making the Mold.......................................................................................................................................................................... 9 Making a Device.........................................................................................................................................................................10 Device Evaluation...........................................................................................................................................................................12 Device Testing..................................................................................................................................................................................12 Results and Discussion.......................................................................................................................................................................13 Mold Characterization..................................................................................................................................................................13 Device Characterization...............................................................................................................................................................14 Videography Data...........................................................................................................................................................................16 Dripping Behavior....................................................................................................................................................................16 Jetting Behavior.........................................................................................................................................................................17 Summary ..................................................................................................................................................................................................18 Conclusions .............................................................................................................................................................................................18 Future Work ...........................................................................................................................................................................................19 Acknowledgements .............................................................................................................................................................................19 Appendix ..................................................................................................................................................................................................20 Matlab Code.......................................................................................................................................................................................20 Channel Measurement Analysis and Plotting ..............................................................................................................20 Video Analysis and Plotting .................................................................................................................................................20 Viscosity Plotting (example)................................................................................................................................................21 Bibliography ...........................................................................................................................................................................................21
  • 3. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 3 TABLE OF FIGURES Figure 1: Flow-Focusing Configurations............................................................................................................................................... 5 Figure 2: Fabrication Overview ................................................................................................................................................................ 9 Figure 3: Bad Spin-Coating.......................................................................................................................................................................... 9 Figure 4: Good Spin-Coating....................................................................................................................................................................... 9 Figure 5: X-Junction, 10x............................................................................................................................................................................10 Figure 6: X-Junction, 20x............................................................................................................................................................................10 Figure 7: X-Junction, 40x............................................................................................................................................................................10 Figure 8: Photomask on SU-8...................................................................................................................................................................10 Figure 9: Finished Mold..............................................................................................................................................................................10 Figure 10: Curing Dish Assembly...........................................................................................................................................................11 Figure 11: Plasma Treatment ..................................................................................................................................................................11 Figure 12: A Complete Device..................................................................................................................................................................11 Figure 13: Micro Hardness Testing.......................................................................................................................................................12 Figure 14: Confocal Microscopy .............................................................................................................................................................12 Figure 15: Preliminary Testing ...............................................................................................................................................................13 Figure 16: High-Speed Videography.....................................................................................................................................................13 Figure 17: Matlab Channel Data Output* ............................................................................................................................................13 Figure 18: JMP Channel Data Output*...................................................................................................................................................13 Figure 19: Table of Statistical Values from JMP...............................................................................................................................14 Figure 20: Device 1, Bottom View..........................................................................................................................................................14 Figure 21: Device 1, Transverse View..................................................................................................................................................14 Figure 22: Device 1, Top View.................................................................................................................................................................15 Figure 23: Device 1, Transverse View..................................................................................................................................................15 Figure 24: Device 2, Top View.................................................................................................................................................................15 Figure 25: Device 2, Transverse View..................................................................................................................................................15 Figure 26: Device 2, Bottom View..........................................................................................................................................................15 Figure 27: Device 2, Transverse View..................................................................................................................................................15 Figure 28: Alginate Viscosity vs Shear Rate ......................................................................................................................................16 Figure 29: Dripping Behavior in Device 4..........................................................................................................................................17 Figure 30: Jetting Behavior in Device 4...............................................................................................................................................18
  • 4. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 4 MOTIVATION UVM’s Engineered Biomaterials Research Laboratory (EBRL) has identified that surgical processes deployed to repair osteochondral defects are largely ineffective. Osteochondral defects (damage to articular cartilage and the underlying bone), caused either by trauma or chronic inflammation, must be treated to avoid the development of chronic osteoarthritis and the degeneration of surrounding joint tissues. Traditionally, surgical procedures take one of three forms: 1) total joint replacement, 2) removal of the damaged tissue and grafting of tissue-engineered cartilage into the osteochondral lesion, or 3) stimulation of the body’s natural repair mechanisms by introduction of microfractures in the subchondral bone. None of these treatments effectively and permanently heal an osteoarthritic joint, and the number of patients experiencing osteoarthritis continues to increase. The EBRL’s proposed solution is a porous, implantable or injectable, three-dimensional, biocompatible tissue scaffold, seeded with drugs and/or human mesenchymal stem cells (hMSCs). To create such a scaffold, biomimetic polymers emulating natural, healthy osteochondral tissue (cartilage and subchondral bone) is poured over a pre-mold of microspheres. The microspheres will dissolve once in the body, releasing drugs and/or hMSCs at a controlled rate, and leaving behind a porous scaffold to support cartilage regrowth. It is crucial that monodisperse microspheres be produced within a set of relevant size ranges. The EBRL has identified microfluidic flow-focusing devices (MFFDs) as an effective, low-cost, and high-throughput mechanism for creating homogeneous microspheres. BACKGROUND MICROFLUIDICS The field of microfluidics concerns itself with the properties, applications, and control of fluidic systems characterized by micro-scale dimensions and volumes. Microfluidics was born in the 1980s from analytical methods and detection systems designed to operate on tiny amounts of sample material. The application of these techniques to chemical and biological weapons detection, molecular biology and genomics analysis, and microelectronics or microelectromechanical systems (MEMS) has since driven the development of the field (Whitesides 2006). Numerous journals highlighting microfluidic systems and results obtained thereby have arisen, including Lab-on-a-Chip, Sensors and Actuators, Microfluidics and Nanofluidics, and Analytical Chemistry. Meanwhile, improvements in available materials, fabrication techniques, and embeddable subsystems have allowed for the advent of comprehensive “lab-on-a-chip” solutions featuring valves, pumps, actuators, switches, sensors, dispensers, mixers, filters, separators, and more (Stone et al. 2004). Microfluidic droplet generators, or MDGs, comprise a specialized class of microfluidic device that leverages flow-focusing geometry and the fluid properties typically observed in microfluidics to create emulsions (Anna et al. 2003). While other methods for creating less monodisperse emulsions exist, the strength of MDGs lies in their ability to produce highly monodisperse microspheres at a broad range of sizes, while supporting various fabrication techniques and a broad range of features and components. MDGs are capable of creating oil-in-water and water-in-oil emulsions, as well as double, triple, and even quadruple emulsions (Abate & Weitz 2009). MDGs retain their capability to produce homogeneous microspheres from fluids with a broad range of properties, yielding microspheres with diameters of 1 – 500 µm (Nie et al. 2008; Dendukuri & Doyle 2009; Weibel & Whitesides 2006). Polymer solutions can be dispersed, formed into special shapes, then crosslinked in situ using either continuous or stop-flow lithography, or chemical crosslinking (S. Xu et al. 2005; Hu et al. 2012). MDGs are also capable of encapsulating living cells in polymeric microspheres with high rates of cell viability, a property crucial to the EBRL’s eventual research goals (Choi et al. 2007; Martinez et al. 2012). TYPES OF DROPLET GENERATORS Three main types of droplet generators exist, and are characterized by the geometry they employ for droplet generation: T-Junction, Co-Flow, and Flow-Focusing. T-Junction droplet generators feature two orthogonal channels where the dispersed fluid is carried by the incident, truncated channel. As fluids are pumped through the junction, break-up of the dispersed fluid occurs as the result of combined shear forces and capillary pressure exerted by the continuous phase (Dendukuri & Doyle 2009).
  • 5. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 5 Co-flow droplet generators generally feature three coaxial channels, where two cylindrical pipettes with tips pulled to a desired diameter are enclosed in a third square tube. The fluid to be dispersed is pumped in through one cylindrical pipette, while the continuous fluid is pumped into the enclosing tube. As the two immiscible phases are pushed into the empty pipette tip, shear forces exerted by the continuous phase pinch the dispersed phase into a fine cylinder. Eventually, the surface energy of the thread becomes too great, and the thread splits into droplets (Baroud et al. 2010; Geschiere et al. 2012). Co-flow droplet generators are capable of producing multiple emulsions, although the simplest co-flowing geometries feature a capillary tube ejecting fluid into a second, flowing, immiscible phase to create a single emulsion (Martinez et al. 2012; Fu et al. 2012). Flow-focusing droplet generators display greater versatility than co-flowing droplet generators, and have three or more distinct configurations. These, as shown in Figure 1, include 1) equidimensional continuous, dispersed, and outflow channels, 2) large continuous and dispersed channels feeding into a small outflow orifice and channel, and 3) small continuous and dispersed channels feeding into a small orifice, which then opens to a wider outflow channel (Abate, Poitzsch, et al. 2009a). All three designs feature co-axial dispersed and outflow channels, with the continuous phase supplied on either side by channels perpendicular to the dispersed and outflow channels. While shear forces and capillary pressure tend to govern droplet breakup, the exact mechanism of breakup is highly dependent on the fluid properties and flow characteristics (Anna et al. 2003; Fu et al. 2012). We chose to focus on flow-focusing microfluidic droplet generators, specifically the first type with equidimensional channels, because 1) they are capable of producing droplets in a wide range of sizes, 2) they are relatively inexpensive to fabricate, and 3) their operating parameters are well understood and highly tuneable (McDonald et al. 2000; Cubaud & Mason 2008). RELEVANT FLUID PARAMETERS Biphasic microfluidic dynamics in a flow-focusing device are governed by a set of parameters calculable from the properties of the two working fluids and the dimensions of the device junction. These are 𝜇 𝑐 and 𝜇 𝑑, the dynamic viscosities, 𝜌𝑐 and 𝜌 𝑑, the densities, 𝑄𝑐 and 𝑄 𝐷, the flow rates, 𝑃𝑐 and 𝑃𝑑, the imposed pressures, and 𝛾, the interfacial tension between the two fluids. The subscripts c and d denote the continuous and dispersed phases, respectively. Due to the various fabrication methods most often used, microfluidic channels are often of uniform height, giving us h, the height of the channels, and 𝑤𝑐 and 𝑤 𝑑, the channel widths. From these, the mean velocity of a flow can be calculated as 𝑈 = 𝑄 𝐴⁄ (Christopher & Anna 2007). Finally, the ratios of volumetric flow rates, viscosities, and channel widths will be denoted as 𝜑 = 𝑄 𝑑 𝑄𝑐⁄ , 𝜆 = 𝜇 𝑑 𝜇 𝑐⁄ , and 𝜒 = 𝑤 𝑑 𝑤𝑐⁄ , respectively (Baroud et al. 2010; Christopher & Anna 2007). From the basic parameters above, a set of dimensionless groups can be calculated to describe fluid behavior inside the device. The first of these is the Reynolds number, which describes the ratio of inertial forces to viscous forces acting on a fluid flow, and is often used to predict the charactistics of flow regimes (e.g. laminar, mixed, turbulent). For closed-pipe flows with rectangular cross-sections, the Reynolds number is formally defined as 𝑅𝑒 = 𝜌𝐷ℎ 𝑈 𝜇⁄ . The characteristic length is taken as the hydraulic diameter, 𝐷ℎ = 4𝐴 𝑃⁄ , where 𝐴 = 𝑤ℎ and 𝑃 = 2𝑤 + 2ℎ for a given channel (White 2010). The second dimensionless group of concern is the Weber numer, which describes the ratio of inertia to surface tension. The Weber number is found from 𝑊𝑒 = 𝜌𝑈2 𝑑 𝛾⁄ , where  is the interfacial tension between the two working fluids, and d is the characteristic diameter of the dispersed phase as it penetrates into the continuous phase. The third dimensionless group to consider is the capillary number, which descibes the ratio of viscosity to surface tension, or the ratio of local shear stress to capillary pressure. For a given flow, Figure 1: Flow-Focusing Configurations Reproduced from (Abate, Poitzsch, et al. 2009a)
  • 6. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 6 the capillary number is calculated by 𝐶𝑎 = 𝜇𝑈 𝛾⁄ or 𝐶𝑎 = 𝜇𝑄 𝐴𝛾⁄ (Nunes et al. 2013; White 2010). As inertial effects are often negligible in microfluidic flows, the capillary number is often used to delineate microfluidic flow regimes. The pronounced influence of device geomtery in microfluidics gives rise to slight modifications in the definitions of relevant dimensionless groups. The Reynolds number is often calculated using channel height as the characteristic length, such as 𝑅𝑒 = 𝜌𝑄ℎ 𝐴𝜇⁄ or 𝑅𝑒 = 𝜌𝑄 𝜇𝑤⁄ , as for a given device, channel height tends to be more consistent than width (Anna et al. 2003). Furthermore, the capillary number has been defined as 𝐶𝑎 = 𝜇 𝑐 𝐺𝑤 𝑑 2𝛾⁄ , where 𝐺 = ∆𝑉 ∆𝑍⁄ , ∆𝑉 being the difference in velocity between the flow-focusing junction and the upstream velocity, and ∆𝑍 being the distance between the end of the dispersed channel to the flow- focusing orifice (Anna & Mayer 2006). The language of dimensionless numbers can greatly facilitate comparison between devices and generalization of results. However, the calculation of relevant fluid parameters, such as interfacial tension, and the measurement of micro-scale internal channels are challanging tasks on their own. The complete characterization of a microfluidic device is a decidedly non-trivial process. FLOW-FOCUSING DYNAMICS As many as five distinct regimes of flow behavior in equidimensional, type 1 microfluidic flow-focusing devices have been identified (threading, jetting, dripping, tubing, and displacement); predicting the transitions between these five is best done using the capillary number (Cubaud & Mason 2008). As flows in microfluidic devices tend to be strongly laminar, with Reynolds numbers rarely increasing above 𝑅𝑒 = 10, microsphere production relies on the occurrance of natural instabilites (Stone & Kim 2001; Tang & Whitesides 2009). The two flow regimes known to produce monodisperse droplets are the jetting and dripping regimes – in the remaining three flow regimes, no droplets, or polydisperse droplets, are produced. THE JETTING REGIME In the jetting regime, shear forces exerted by the continuous phase draw a cylindrical thread of the dispersed fluid through the flow-focusing junction. Monodisperse droplets form downstream of the junction due to axisymmetric capillary instabilities that occur in the thread (Eggers 1997; Geschiere et al. 2012). Jetting behavior occurs for 𝐶𝑎 𝑑 > 0.1. During operation, the capillary thread characteristic of the jetting regime reaches a critical length 𝐿 𝑐 where droplets break off, such that 𝐿 𝑐 ≈ 𝜇 𝑑 𝛾 8 𝜋ℎ𝐶𝑎 𝑐𝑟𝑖𝑡 ( 𝑄 𝑑 𝑄𝑐 2 ) 0.5 Eq. 1 where 𝐶𝑎 𝑐𝑟𝑖𝑡 represents the threshold capillary number, above which convective instabilities drive droplet breakup. Furthermore, the diameter of the droplets produced can be predicted by the relation 𝑑 ℎ ≈ 2.192𝜑0.5 Eq. 2 revealing the dimensionless droplet size to be a function of the flow rates of the fluids. This relation holds regardless of the relative size of the droplets in their channel, and it is noted that droplets smaller than their enclosing channel are produced when 𝜑 < 𝜑 𝑐𝑟𝑖𝑡, where 𝜑 𝑐𝑟𝑖𝑡 ≈ 0.21 (Cubaud & Mason 2008). Fu et al propose a more nuanced relation governing droplet size in the jetting regime: 𝑑 𝑤 𝑑 ≈ { 1.23𝜑0.41 ; 1 < 𝜆 < 12 13.64𝜑1.07 ; 𝜆 ≈ 112 Eq. 3 where the second condition 𝜆 ≈ 112 is mentioned in the literature simply as “high viscosity contrast” (Fu et al. 2012). THE DRIPPING REGIME In the dripping regime, a hemispherical cap of the dispersed fluid protrudes from the dispersed channel until it begins to obstruct the outflow orifice, at which point capillary pressure and shear forces from the continuous phase pinch the cap of the dispersed phase into a droplet, and the dispersed phase retracts to the opening of its channel (Nunes et al. 2013; Garstecki et al. 2005). Dripping behavior occurs for 𝐶𝑎 𝑑 < 0.1 and
  • 7. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 7 𝐶𝑎 𝑐 < 0.1, the lower capillary numbers revealing the greater relative influence of surface tension on the flows. The diameter of the droplets produced in the dripping regime conform to two distinct sub-domains, separated by 𝑑 𝑐𝑟𝑖𝑡 ℎ⁄ ≈ 2.5, and described as 𝑑 ℎ ≈ { 2.2 × 10−3 𝛼 𝑐 𝐶𝑎 𝑐 ; 𝑑 > 2.5ℎ 1 2(𝛼 𝑐 𝐶𝑎 𝑐)0.17 ; 𝑑 < 2.5ℎ Eq. 4 where 𝛼 𝑐 = 𝑄𝑐 (𝑄𝑐 + 𝑄 𝑑)⁄ (Cubaud & Mason 2008). A second, similar relation for equidimensional cross- junction is proposed to be 𝑑 𝑤 𝑑 ≈ { 0.72𝜑0.14 𝐶𝑎 𝑐 0.19 ; 𝑑 ≤ 2.35𝑤 𝑑 0.30𝜑0.23 𝐶𝑎 𝑐 0.42 ; 𝑑 > 2.35𝑤 𝑑 Eq. 5 where droplet diameter is non-dimensionalized using the width of the channels, rather than the height (Fu et al. 2012). Both relations reveal the droplet diameter in the dripping regime to be a function of the ratio of the flow rates, the geometry of the channels, and the capillary number of either the dispersed or the continuous flow, despite large size differences in the devices used by the two groups, Cubaud and Mason, and Fu et al. FABRICATION METHODS FOR MICROFLUIDIC FLOW-FOCUSING DEVICES Flow-focusing and T-Junction droplet generators can be fabricated in a variety of methods (Martinez et al. 2012; Tang & Whitesides 2009). The first generation of microfluidic devices were fabricated using techniques developed for microelectronics, and consisted of photolithography or electron-beam lithography in silicon and glass. Although these methods produce dimensionally accurate and chemically inert devices, they have been critiqued for being expensive, inflexible, dependent on specialized equipment, and useful only for planar geometries – silicon or glass devices are better suited for factory production than lab work (Tang & Whitesides 2009; Whitesides & Stroock 2001). Researchers in the field sought to develop faster, cheaper, and more versatile fabrication systems that retained the dimensional stability and precision of the silicon and glass devices. As of 2008, silicon, silica, or glass microfluidic devices were still the most used in publications, followed by poly(dimethylsiloxane) (PDMS), then thermoplastics, such as polymethylmethacrylate (PMMA), polycarbonate (PC), copolymers and cyclic olefin polymers (COC and COP), among others (Tsao & DeVoe 2008). Various methods exist for fabricating microfluidic channels from plastics, including hot embossing (Martynova et al. 1997), cold embossing (J. Xu et al. 2000), injection molding (McCormick et al. 1997), microthermoforming (Giselbrecht et al. 2006), and CO2 laser machining/IR laser engraving (Romoli et al. 2011; Huang et al. 2006). While thermoplastics are cheap and easily etched, engraved, or through-cut using a laser cutter, bonding multiple layers of engineering plastics can become problematic: resins and other glues tend to result in fouling of the channels, while direct bonding by thermal fusion requires intimate thermal control during the bonding process, and like bonding via solvent addition, tends to result in poor dimensional stability or channel collapse. However, welding via laser or ultrasonic energy, especially if enhanced by surface modifications to the bonded plastics, offer promising alternatives and open the door for high-volume production (Tsao & DeVoe 2008). Of all the materials discussed above, PDMS is by far the most flexible, featuring a Young’s modulus of 0.750 MPa < E < 1.0 MPa, and supporting a broad array of geometries and integratable components (Dendukuri et al. 2007; Unger 2000). Planar PDMS devices are most commonly formed in a process known as soft-photolithography, whereby 1) a mold is made by hardening a photoresist under light through a photomask, 2) liquid PDMS and a curing agent are poured over top of the mold and allowed to solidify into a slab, 3) the slab is peeled from the mold and bonded to a glass slide or a second PDMS sheet, and 4) holes are cut and tubing is inserted into the new device (Duffy et al. 1998). The simplicity of this method allows for
  • 8. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 8 rapid prototyping from CAD files (McDonald et al. 2000). The bonding step is crucial and can be performed reversibly via Van der Waals contact with a second surface, or irreversibly, by activating the PDMS surface with oxygen plasma and allowing Si-O-Si bonds to form with glass, resulting in a bond capable of withstanding pressures up to 207-345 kPa (McDonald et al. 2000). In addition to the stamping/casting process described above, PDMS can also be formed via wet etching, dry etching, or a combination of the two (Garra et al. 2002; Balakrisnan et al. 2009). This bonding technique enables the stacking of multiple layers of naturally elastomeric PDMS for the creation of complex, three-dimensional mixers (Jo et al. 2000), pneumatic/hydraulic “Quake” microvalves (Wang & Lee 2013), screw and solenoid microvalves (Hulme et al. 2009), pneumatic/hydraulic micropumps (Unger 2000), prefabricated heaters (Erickson & Li 2004), and heaters fabricated in situ by cooling liquid solder in microfluidic channels (Tang & Whitesides 2009). The resulting complexity of microfluidic devices is impressive. Examples include devices that use pneumatic valves to change the size and frequency of droplets during production (Abate, Romanowsky, et al. 2009b), devices featuring one to five sequential, alternatively- wetting flow-focusing junctions for single- to quintuple-emulsions (Abate & Weitz 2009), and a flow-focusing droplet generation and sorting device featuring embedded, computer-controlled laser-detection and a pressure-actuated valve to separate light from dark droplets at rates of up to 250 Hz with < 0.01% error (Abate et al. 2010). While glass may retain the best dimensional stability and chemical inertness and engineering plastics may be cheaper and faster to fabricate or mass-produce, the moderate cost, low turnaround time, and incredible flexibility of PDMS microfluidic devices make them optimal for our somewhat open-ended applications. OBJECTIVES Accurate and reliable protocols will be developed for the fabrication, evaluation, and testing of PDMS microfluidic devices, with the ultimate goal of producing homogeneous microspheres between 1 and 200 µm in diameter using fluids relevant to the EBRL’s research aims. Using the developed protocols, one or more microfluidic flow-focusing devices will be fabricated, evaluated, and tested. Data collected will be displayed analytically, and, if possible, statistically. Its dimensions will be characterized and compared to the intended design. The device will be filmed under operation using high-speed videography. METHODS The bulk of the time spent on this research went into developing and refining the various steps of the fabrication procedures for PDMS microfluidic devices. Due to the number of steps in the fabrication process, adequate completion of a step often becomes more important than perfection (for example, the necessity for spin-coating to produce an even film is crucial, bet producing a film within +/- 1 µm of the intended thickness is secondary). Early devices suffered due to problems with nearly every step in the fabrication process. Protocol modifications were sometimes suggested by literature, but groups publishing results obtained with microfluidic devices tend not to reveal the details of their fabrication methods.
  • 9. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 9 DEVICE FABRICATION PROCEDURE OVERVIEW PDMS microfluidic devices are made in a multi-step process that increases in complexity with the design intent. For planar microfluidic devices, a casting/stamping procedure is used. First, a mold is made. This is accomplished by applying an even film of photoresist to a substrate (glass or silicon) then selectively hardening the photoresist with light through a photomask, sometimes called a transparency. The excess unhardened photoresist is washed off of the substrate to create the mold, referenced in Figure 2 as a master. To create the device, PDMS is then mixed, poured over the mold, and hardened (note: PDMS curing time varies with composition, thickness, and thermal properties of the surrounding materials). Once cured, the PDMS slab is peeled from the mold and bonded to a microscope slide or a second slab of PDMS to create microchannels. Finally, if necessary, tubing is fitted to the new device, allowing for fluids to be pumped through. MAKING THE MOLD To make a microfluidic device, a mold must be made by selectively hardening a photoresist on a glass slide. SU-8 2075 (MicroChem) is a negative photoresist known for its ability to create features with high aspect ratios. First, a glass slide (75mm x 25mm, Fisher Scientific) is cleaned and dried, then placed on the vacuum head of a spin coater (Laurell Technologies WS-400BZ-6NPP/LITE). SU-8 is deposited atop the glass slide then spun to produce a film of uniform thickness. Film thickness varies inversely with rotational velocity: SU-8 2075 produces a thickness of ~240 µm at 1000 rpm, and ~60 µm at 4000 rpm (MicroChem 2006). This step of the process is highly sensitive to contamination; small dust particles can result in non-uniform films of SU-8. Optical examination immediately after spin coating reveals the uniformity of the SU-8 film, as shown in Figures 3 and 4. Figure 3: Bad Spin-Coating Figure 4: Good Spin-Coating A non-uniform SU-8 film A uniform SU-8 film Immediately after spin coating, the coated slide is placed on a hot plate (VWR Int’l. 11301-068) and undergoes a pre-exposure bake, in which it is heated to 65 ˚C for five minutes, cooled to room temperature, then heated to 95 ˚C for 10 minutes. This evaporates remaining solvents in the SU-8, and can help smooth wrinkles that may have appeared during coating. A custom photomask, designed in Solidworks and fabricated by (PhotomaskPORTAL) is then applied (see Figure 8). Exposing the SU-8 requires between 150-350 𝑚𝐽 𝑐𝑚2 of near-UV light (IntelliRay 400 W) and correlates to film thickness. For films of this thickness, 4-5 seconds of exposure hardens the photoresist in the necessary shapes. After curing, a post-exposure bake is performed, Figure 2: Fabrication Overview Simplified schematic for PDMS microfluidic device fabrication, reproduced from (McDonald & Whitesides 2002).
  • 10. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 10 where the slide, now bearing both hardened and uncured SU-8, is heated to 65 ˚C for two minutes, cooled to room temperature, then heated to 95 ˚C for 10 minutes. All uncured SU-8 is washed off by submerging the slide in ethyl lactate and gyrating (VWR Int’l OS-500) for eight minutes, twice. At this point, the SU-8 molds are evaluated under an optical microscope (Fisher Scientific, 12-561-330) to ensure that they are free of defects. The critical x-junction at the center of the mold is of particular interest. Figures 5 through 7 show high quality mold features at varying levels of magnification. The verticality of the sidewalls and the smoothness of the top of the features are evaluated. The creases, visible in Figures 6 and 7, are likely due to thermal stresses, but have not been shown to affect the resulting device. A mold that fails to pass optical inspection is discarded. Figure 5: X-Junction, 10x Figure 6: X-Junction, 20x Figure 7: X-Junction, 40x Mold used to make device 1, 10x magnification Mold used to make device 1, 20x magnification Mold used to make device 1, 40x magnification Finally, the finished mold is placed in a vacuum chamber (Cole-Parmer Instrument Co., P-79202-00) with 200 µL (tridecafluoro-1,1,2,2-tetrahydrooctyl)-1-trichlorosilane (Sigma-Aldrich). Inside the vacuum chamber, the silane is vaporized and evenly coats the glass and SU-8 features, preventing the PDMS from sticking to the mold. A finished mold is visible in Figure 9. Figure 8: Photomask on SU-8 Figure 9: Finished Mold Applying a photomask to a slide coated in uncured SU-8 photoresist Exposed, rinsed, and silanized, a mold with visibly raised features reposes in its custom-made curing dish is ready for PDMS MAKING A DEVICE Polydimethylsiloxane (PDMS) (Dow Corning, Sylgard 184) is used to create the device. PDMS is a two- part product. It is thoroughly mixed in a 10:1 ratio of elastomer base and curing agent, then centrifuged at 4000 rpm to accelerate degassing. About 22 mL of PDMS are necessary to make one device. The mold is placed into a custom curing plate, designed in Solidworks and fabricated in-house, which also contains the PDMS as it cures on a hot plate. Centrifuged PDMS is poured into the curing plate over the mold, as seen in Figure 10. To eradicate the bubbles that inevitably form in concave corners of the mold features, the full curing dish is placed back in the vacuum desiccator, and a vacuum is cyclically pulled and released until all
  • 11. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 11 bubbles rise to the surface of the PDMS. This done, the curing dish is placed on a hot plate, and cured at any temperature between 70 ˚C and 150 ˚C (leading to approximate curing times of two and a half hours and half an hour, respectively). Devices cured at lower temperature show less thermal distorsion and fewer air bubbles than devices cured at high temperature. Once cooled, the now hard PDMS slab is gently peeled from its mold and curing dish. The raised features on the mold are now impressed into the underside of the PDMS slab. With a razor blade, the slab is trimmed to fit on a new 75mm x 25mm slide. A 1.5mm biopsy punch (Fisher Scientific) is used to create holes for three 0.0625” OD teflon tubes (McMaster-Carr). In order to create closed microfluidic channels capable of withstanding high pressure without bursting, PDMS and glass are chemically bonded. Air plasma, visible in Figure 11, is generated using a corona wand (Electro-Technic Products, BD20AC), The plasma alters the surface chemistry of the new glass slide and the new PDMS slab, allowing the surfaces to bond on contact. The resulting covalent siloxane (Si—O—Si) bonds that form at the interface are stronger than the PDMS itself (Duffy et al. 1998). Unfortunately, this treatment also makes the microfluidic channels temporarily hydrophyllic, which is unfavorable for creating water-in-oil emulsions. Finally, the teflon tubes are inserted, as is visible in Figure 12, and the device is ready for testing. Figure 10: Curing Dish Assembly Figure 11: Plasma Treatment Partially degassed PDMS in a curing dish Activating the surface of a clean glass slide with a corona wand Figure 12: A Complete Device A completed, final-generation device ready for testing.
  • 12. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 12 DEVICE EVALUATION Microfluidic devices fabricated using the above procedure were evaluated using a variety of methods. Due to the time-intensive nature of PDMS microfluidic device fabrication, some level of evaluation occurred at each stage of fabrication to ensure that the resulting device would not be defective. Spin-coated glass slides are observed using the naked eye to ascertain film flatness, as seen in Figures 2 and 3. Hardened molds are evaluated for obvious defects using an optical microscope, as seen in Figures 5 through 7. Lastly, the x- junctions of hardened molds are measured using a micro hardness tester (Beuhler, Micromet II), as seen in Figure 13. The calibrated vertical bars are moved together or apart, and the gap between the two can be read off a dial on the apparatus. Channel width in each direction at the x-junction is measured three times consecutively for statistical power. Once deemed viable, a mold is silanized and used to create a device. Upon peeling a PDMS slab from the mold, the slab and mold checked to ensure that no chunks of hardened SU-8 are stuck in the PDMS channels – any stuck chunks are gently removed. The slab is then bonded to a glass slide as described above. Evaluation under a microscope is often ineffective, as bonding problems will only present themselves once the device is pressurized. To characterize the dimensions of microfluidic channels at higher resolution, the device is pumped full of a red fluorescent stain (Acti-Stain 555). A confocal microscope (Zeiss, LSM 510 META) is used to obtain a set of two-dimensional images in the x-y plane with varying focal depth. This set, known as a z-series, is then reconstructed in specialized software (Volocity) to form a measurable three-dimensional rendering. Sample results from confocal microscopy are visible in Figure 14. The viscosities of the working fluids were evaluating using a shear-rate sweep on the EBRL’s rheometer (TA Instruments, AR2000). Figure 13: Micro Hardness Testing Figure 14: Confocal Microscopy A mold for a microfluidic device as seen through the micro hardness tester. Flourescent channels of the microfluidic device made from the mold in Figure 12 as seen in confocal microscopy. DEVICE TESTING From an understanding of the device dimensions, the properties of the working fluids, and relationships proposed by previous literature, a range of potentially viable flow rates to test is determined (Nie et al. 2008; Cubaud & Mason 2008). To ascertain whether or not a device will function, preliminary tests are performed under an optical microscope (see Figure 15). Once a device is shown to be operational through preliminary testing, high-speed videography is used to analyze the size, dynamics, and rate of formation of droplets produced by a device, as shown in Figure 16.
  • 13. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 13 Figure 15: Preliminary Testing Figure 16: High-Speed Videography An older revision of a microfluidic device undergoes preliminary testing under the EBRL’s microscope. The most recent microfluidic device undergoes testing and filming using high-speed videography. Visible in Figure 16, but not in Figure 15, is the pair of syringe pumps (Harvard Apparatus, PHD-2000), used to feed fluids to microfluidic devices. As seen in Figure 16, high-speed videography is performed with a high-speed camera (Phantom, v310), which is equipped with an objective microscopic lens (Mitituyo, Plan Apo 20x) and an in-line fiber optic light source (Edmund Industrial Optics, 21AC). Specialized software is used to control the high-speed camera (Vision Research, Phantom Camera Control), while more standard software is used to convert the high-speed videography output into videos (Apple, Quicktime Pro). High- speed videography data was processed using Matlab routines developed for monopropellant microthruster research. RESULTS AND DISCUSSION MOLD CHARACTERIZATION The above fabrication protocol was used to fabricate four molds during the fall of 2014. The x-junctions of these molds were measured in two dimensions as described above using a micro hardness tester, as in Figure 12, and the resulting data is plotted below. Note: channel height data was obtained via confocal microscopy on devices resulting from the molds measured using the micro hardness tester. Figure 17: Matlab Channel Data Output* Figure 18: JMP Channel Data Output* Figures 17 and 18 show the mean width of the longitudinal and transverse channels at the x-junction of each of the four molds. Each channel is measured three times. Figure 17 displays the standard deviation of each set of three measurements, while Figure 18 shows the upper and lower control limits of the data (𝑈𝐶𝐿 = 80.37 µm and 𝐿𝐶𝐿 = 78.02 µm, respectively). It is noteworthy that the control limits shown in Figure 18 are artificially small due to small sample size – only three samples comprise each data point in this graph. Both plots show the global mean channel width, µ = 79.20 µm, very close to the intended value of 80 +/- 5 µm. This tolerance comes from the fabricator of the photomask, who claims 5000 dpi, or 5.08 µm resolution.
  • 14. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 14 Device Mean (Width, 1) Mean (Width, 2) Std Dev (Width, 1) Std Dev (Width, 2) Range (Width, 1) Range (Width, 2) Mean 2 Minus Mean 1 1 86.800 89.033 0.819 0.751 1.600 1.500 2.233 2 81.500 84.633 0.608 0.231 1.100 0.400 3.133 3 66.100 67.800 0.954 0.300 1.700 0.600 1.700 4 78.467 79.233 0.681 0.503 1.300 1.000 0.767 Means: 78.217 80.175 0.765 0.446 1.425 0.875 1.958 Figure 19: Table of Statistical Values from JMP* Figure 19 supports the above graphs with numerical data. All devices feature longitudinally oriented channels wider than transversally oriented channels by 1.968 µm, on average, but the difference in channel width (“Mean 2 Minus Mean 1” in Figure 19) does not correlate with the magnitude of the channel widths. This value is within the tolerance of the photomask, and as it is relatively consistent across all devices, it can be attributed to error in the fabrication of the device. The low standard deviations observed for set of channel measurements show relatively precise data collection. DEVICE CHARACTERIZATION From the confocal microscopy data obtained of Devices 1 and 2, UVM’s Microscopy Imaging center returned still images, three-dimensional reconstructions and fly-though videos, and partial dimensions of Devices 1 and 2. Still images are included below in Figures 20 through 27. Figure 20: Device 1, Bottom View Figure 21: Device 1, Transverse View * All values in µm
  • 15. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 15 Figure 22: Device 1, Top View Figure 23: Device 1, Transverse View Figure 24: Device 2, Top View Figure 25: Device 2, Transverse View Figure 26: Device 2, Bottom View Figure 27: Device 2, Transverse View The images obtained via confocal microscopy reveal microfluidic channels of mixed quality. It is immediately visible that the sidewalls of channels in both devices are not vertical. The effect is not visible only in the wide sections of the microfluidic channels, but also in the critical, choked x-junction. This could be due to the scattering of UV light as the photoresist is hardened, but it is more likely that the tapering be the result of deformation as the PDMS slab is “rolled” onto its glass slide after plasma treatment. These problems can be solved by ensuring that the photomask is pressed tightly to the surface of the SU-8 photoresist before hardening, and by deforming the PDMS slab less as it is affixed to the glass slide, respectively. As can be seen in the above images, the channels of Device 1 are higher than those of Device 2. The height of Device 1’s channels at the x-junction was estimated by the MIC at 71.775 µm, while the height of Device 2’s
  • 16. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 16 channels was at the x-junction was extimated at 45.675 µm. It is unclear exactly why this difference occurred, as the two molds were created using identical procedures. As mentioned before, minor impurities can have dramatic impacts on the uniformity of the photoresist film, thus, to help eradicate this inconsistency, slides should be treated with extreme care from initial cleaning to after the photoresist is hardened. VIDEOGRAPHY DATA A microfluidic flow-focusing device, fabricated using the above methods from mold 4 (see Figures 17 through 19) was tested using the setup shown in Figure 16. 2% sodium-alginate in deionized water dyed with Trypan blue (Sigma-Aldrich, CAS: 72-57-1) was pumped into the device as the dispersed phase, while light mineral oil (Sigma-Aldrich, CAS: 8042-47-5) was pumped into the device as the continuous phase. A typical viscosity profile for 2wt% sodium-alginate is included in Figure 28. The Na-alginate solution exhibits slight shear-thinning behavior, decreasing in viscosity from 0.7 to 0.3 Pa*s over the range of shear rates tested. The light mineral oil is considered Newtonian with a viscosity of .03 Pa*s (Sigma-Aldrich 2011). Code used to produce Figure 28 can be found in the appendix. During videography testing, data was recorded at 2000 frames per second, and saved either as individual .jpg files, or as .mov files for ease of use. The test protocol described in Figure 16 was applied directly, with two syringe pumps delivering one fluid each at finely controllable flow rates. To finely tune the position of the camera, the device was placed on a stage that can be adjusted in three dimensions. Device 4, visible in Figures 12 and 16, displayed three of the five behaviors seen in microfluidic flow- focusing devices: tubing, dripping, and jetting. Although tubing is a curious behavior to observe, it is secondary to the research objectives and was not recorded. Dripping was the most commonly observed behavior, occurring at lower total flow rates, but at a broad range of flow-rate ratios. Jetting behavior was also achieved, despite its relative difficulty. DRIPPING BEHAVIOR The following sequence of still images showcases the dripping behavior of Device 4. At 2000 fps, each frame represents a 0.5 ms advancement in time from the previous. Oil enters through the left and right channels, while 2wt% Na-Alginate enters through the top channel and protrudes into the x-junction. The net direction of the flow is downwards. Figure 28: Alginate Viscosity vs Shear Rate
  • 17. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 17 D.1 D.2 D.3 D.4 D.5 D.6 D.7 D.8 D.9 D.10 D.11 D.12 D.13 D.14 D.15 D.16 D.17 D.18 D.19 D.20 D.21 D.22 D.23 D.24 D.25 D.26 Figure 29: Dripping Behavior in Device 4 Over the course of the 26 frames above, one droplet of 2wt% Na-Alginate is produced. Roughly 12.5 ms transpire; during this period of steady state operation, droplets were produced at about 80 Hz. The droplet breakup dynamics characteristic of the dripping regime are showed step-by step in this sequence: the cycle begins with the dispersed phase protruding out into the junction from the dispersed channel. As it blocks more and more of the outflow orifice, capillary pressure and shear force from the impinging oil pinch the dispersed phase until a new droplet breaks off. Although the new droplet in D.26 shares its position with the new droplet in D.1, creating the impression that a whole cycle has occurred, care must be taken to comprehensively evaluate the flow. A glance downstream at the droplets populating the efflux channel in D.26 shows that they are on opposite sides of a hypothetical centerline of the device. Thus, it is more correct to conclude that over 25 ms two droplets are produced. Using the width of the x-junction, found to be measure roughly 79 µm, the diameter of the droplets produced can be estimated at roughly 70 µm. JETTING BEHAVIOR The following sequence of images shows Device 4 displaying jetting behavior. The video data was recorded at 2000 fps, but in this sequence, only half the frames are displayed, yielding an effective frame rate of 1000 fps and 1 ms time advancement between frames. The orientation of the device is the same as in the previous sequence of images.
  • 18. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 18 J.1 J.3 J.5 J.7 J.9 J.11 J.13 J.15 J.17 J.19 J.21 J.23 J.25 J.27 J.29 J.31 J.33 J.35 J.37 J.39 Figure 30: Jetting Behavior in Device 4 In this sequence, one microsphere is produced over the course of 38 ms, giving a frequency of approximately 26.3 Hz. Classing dripping regime droplet breakup dynamics are showcased in this sequence. In contrast with the previous segment, droplet breakup occurs downstream of the x-junction. Increased shear forces pull the dispersed phase into a capillary thread as it passes through the x-junction. Plateau-Rayleigh instabilities appear as axisymmetric ripples in the dispersed phase thread in the otherwise highly regular flow. Eventually, as predicted, the surface energy becomes too high, and the capillary thread breaks off another microspheres. SUMMARY Over the course of this research, an understanding of the fluid mechanics driving microfluidic droplet generation through flow-focusing was obtained through a study of extant literature. Techniques for the fabrication of PDMS microfluidic devices were developed and refined, then codified as procedures for laboratory use. Various methods for characterizing the dimensions of a PDMS microfluidic device were investigated and used to inform design decisions and support modifications to fabrication procedures. Protocols for testing microfluidic devices were created, and the performance of microfluidic flow-focusing devices was demonstrated through high-speed videography. CONCLUSIONS The groundwork laid by this research was sufficient to produce a PDMS microfluidic flow-focusing device capable of generating microspheres of sizes useful to the Engineered Biomaterials Research Laboratory’s research aims.
  • 19. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 19 FUTURE WORK While previous improvements in procedures could be made based on largely subjective assessments, statistical analysis is required to assess the most important next steps forward. Thus, the first step to take is to make at least 30 more devices using the above procedures. Once the consistency of the fabrication methods is assessed quantitatively (and not qualitatively or with too few samples) devices with different dimensions should be fabricated, evaluated, and tested in order to begin making microspheres of smaller size. This done, the EBRL will be able to apply this research to its various projects requiring microspheres, including photocrosslinked alginate microspheres, osteochondral repair systems, and pleural sealant patches. ACKNOWLEDGEMENTS I would like to thank Dr. Oldinski, my advisor and PI, for her support and mentorship. I owe immense thanks to committee members Dr. Hitt and Dr. Sansoz for generously offering their time, techniques, advice, and equipment. I thank Dr. McDevitt for his high-speed videography wisdom. I would also like to give thanks to the many members of the EBRL who have helped out at various points along the way, including Patrick Charron, Spencer Fenn, Meredith Koch, Tianxin Miao, Alex Poniz, and Emily Miller. Thanks go to Nicole Bishop and Nicole Bouffard at the UVM Microscopy Imaging Center for their help with confocal microscopy, to Marc “Stump” Soldini, from whom I inherited this project, to Danielle Dawson for lending a hand with statistical analysis, and to Floyd Vilmont of UVM’s Machine Shop for his help in metal fabrication. A special thank-you goes to Aly Johnson-Kurts, for her patience with nerdy engineering jargon and her keen eye for editing. This research was funded in part by UVM’s Office of Undergraduate Research.
  • 20. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 20 APPENDIX Relevant video data not included will be shown and distributed during defense. MATLAB CODE CHANNEL MEASUREMENT ANALYSIS AND PLOTTING % Device dimensions clc;clear all;clf; dims = [85.9 89.0 81.8 84.5 66.6 67.5 77.7 78.7; 87.5 88.3 80.8 84.9 65.0 67.8 79.0 79.3; 87.0 89.8 81.9 84.5 66.7 68.1 78.7 79.7]; molds = {'Mold 1, Tr' 'Mold 1, Lo' 'Mold 2, Tr' 'Mold 2, Lo' 'Mold 3, Tr' 'Mold 3, Lo' 'Mold 4, Tr' 'Mold 4, Lo'}; means = [mean(dims(:,1)) mean(dims(:,2)) mean(dims(:,3)) mean(dims(:,4)) mean(dims(:,5)) mean(dims(:,6)) mean(dims(:,7)) mean(dims(:,8))]; specDifs = [abs(means(1) - means(2)) abs(means(3) - means(4)) abs(means(5) - means(6)) abs(means(7) - means(8))]; meanDifs = mean(specDifs); stds = [std(dims(:,1)) std(dims(:,2)) std(dims(:,3)) std(dims(:,4)) std(dims(:,5)) std(dims(:,6)) std(dims(:,7)) std(dims(:,8))]; bar(means) hold on errorbar(means,stds,'r.') plot([0 9],[mean(means) mean(means)],'g--') set(gca,'XTickLabel',molds) str1 = 'Global Mean: '; str2 = num2str(mean(means)); str3 = 'mu'; str4 = 'm'; text(5,82,strcat(str1,str2,str3,str4)) xlabel('Molds 1-4, Widths 1 and 2') ylabel('Channel Width, um') legend('Mean Channel Widths','Standard Deviation','Global Mean','Location','SouthEast') title('MFFD x-junction Dimensions') print(gcf,'ChannelDims','-r1000','-djpeg') VIDEO ANALYSIS AND PLOTTING format short FrameRate = 20000; MaxFrame = 2461; ImageData = cell(1,MaxFrame); for FrameNumber=1:MaxFrame if FrameNumber<10 FrameName = ['000' num2str(FrameNumber) '.jpg']; elseif FrameNumber<100 FrameName = ['00' num2str(FrameNumber) '.jpg']; elseif FrameNumber<1000 FrameName = ['0' num2str(FrameNumber) '.jpg']; else FrameName = [num2str(FrameNumber) '.jpg']; end ImageData{FrameNumber} = imread(FrameName); [ nrow, ncol, ndim ] = size(ImageData); ImageData{FrameNumber} = ImageData{FrameNumber}(24:48,32:793,:); %The numbers help to zoom in on the dimensions of the channel background = imopen(ImageData{FrameNumber},strel('disk',15)); ImageData{FrameNumber} = ImageData{FrameNumber} - background; ImageData{FrameNumber} = imadjust(ImageData{FrameNumber}); level = graythresh(ImageData{FrameNumber}); bw = im2bw(ImageData{FrameNumber},level); bw = bwareaopen(bw, 50); end PixData = ImageData{FrameNumber}(:,:,1); PixData = mean(PixData,1); PixData = double( double(PixData) - mean(PixData)); % Plot the pixel intensity data figure; plot(PixData); % This just shows the average peaks and valleys that the FFT is % based upon. If it's not giving you roughly the same profile as % you're seeing in your images, then the image thresholding may not % be working properly.
  • 21. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 21 % Compute and plot power spectrum for intensity sequence NPixData = length(PixData); MyFFT= fft(PixData); % compute FFT MyPow = MyFFT.*conj(MyFFT); % compute power spectral density MyPow = MyPow/max(MyPow); % normalize spectral data freqrange = linspace(0,0.5,round(NPixData/2))*FrameRate; figure; semilogx(freqrange,MyPow(1:NPixData/2)); xlabel('Frequency(Hz)') ylabel('Normalized Spectral Density') fid = fopen('pixdata.txt', 'w'); for f = 1:NPixData fprintf(fid, '%6.2fn', PixData(f)); end fclose(fid); fid1 = fopen('powdata.txt', 'w'); for f = 1:NPixData/2 fprintf(fid1, '%6.2fn', MyPow(f)); end fclose(fid1); VISCOSITY PLOTTING (EXAMPLE) clc;clear all; filename = '2wt% AAMA in 1xPBS visco 1-0007f exp.txt'; fid = fopen(filename); data = textscan(fid,'-%f %f %f %f %f %f %f %f;','HeaderLines',7) normalForce = data{1}; shearRate = data{2}; time = data{3}; velocity = data{4}; viscosity = data{5}; handie = figure; plot(shearRate,viscosity,'bo') title('2wt% AAMA Viscosity vs. Shear Rate') ylabel('Viscosity (Pa*s)') xlabel('Shear Rate (1/s)') axis([0 1.1*max(shearRate) 0 1.1*max(viscosity)]) filename = filename(1:end-4); filename = strcat(filename,'.jpg'); print(handie,filename,'-r800','-djpeg'); BIBLIOGRAPHY Abate, A.R. & Weitz, D.A., 2009. High-Order Multiple Emulsions Formed in Poly(dimethylsiloxane) Microfluidics. Small, 5(18), pp.2030–2032. Abate, A.R., Agresti, J.J. & Weitz, D.A., 2010. Microfluidic sorting with high-speed single-layer membrane valves. Applied Physics Letters, 96(20), p.203509. Abate, A.R., Poitzsch, A., et al., 2009a. Impact of inlet channel geometry on microfluidic drop formation.
  • 22. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 22 Physical Review E, 80(2), p.026310. Abate, A.R., Romanowsky, M.B., et al., 2009b. Valve-based flow focusing for drop formation. Applied Physics Letters, 94(2), p.023503. Anna, S.L. & Mayer, H.C., 2006. Microscale tipstreaming in a microfluidic flow focusing device. Physics of Fluids, 18(12), p.121512. Anna, S.L., Bontoux, N. & Stone, H.A., 2003. Formation of dispersions using “flow focusing” in microchannels. Applied Physics Letters, 82(3), pp.364–366. Balakrisnan, B., Patil, S. & Smela, E., 2009. Patterning PDMS using a combination of wet and dry etching. Journal of Micromechanics and Microengineering, 19(4), p.047002. Baroud, C.N., Gallaire, F. & Dangla, R., 2010. Dynamics of microfluidic droplets. Lab on a Chip, 10(16), pp.2032–2045. Choi, C.-H. et al., 2007. Generation of monodisperse alginate microbeads and in situ encapsulation of cell in microfluidic device. Biomedical Microdevices, 9(6), pp.855–862. Christopher, G.F. & Anna, S.L., 2007. Microfluidic methods for generating continuous droplet streams. Journal of Physics D: Applied Physics, 40(19), pp.R319–R336. Cubaud, T. & Mason, T.G., 2008. Capillary threads and viscous droplets in square microchannels. Physics of Fluids, 20(5), p.053302. Dendukuri, D. & Doyle, P.S., 2009. The Synthesis and Assembly of Polymeric Microparticles Using Microfluidics. Advanced Materials, 21(41), pp.4071–4086. Dendukuri, D. et al., 2007. Stop-flow lithography in a microfluidic device. Lab on a Chip, 7(7), p.818. Duffy, D.C. et al., 1998. Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane). Analytical Chemistry, 70(23), pp.4974–4984. Eggers, J., 1997. Nonlinear dynamics and breakup of free-surface flows. Reviews of Modern Physics, 69(3), pp.865–929. Erickson, D. & Li, D., 2004. Integrated microfluidic devices. Analytica Chimica Acta, 507(1), pp.11–26. Fu, T. et al., 2012. Droplet formation and breakup dynamics in microfluidic flow-focusing devices: From dripping to jetting. Chemical Engineering Science, 84(C), pp.207–217. Garra, J. et al., 2002. Dry etching of polydimethylsiloxane for microfluidic systems. Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films, 20(3), p.975. Garstecki, P., Stone, H.A. & Whitesides, G.M., 2005. Mechanism for Flow-Rate Controlled Breakup in Confined Geometries: A Route to Monodisperse Emulsions. Physical Review Letters, 94(16), pp.1–4. Geschiere, S.D. et al., 2012. Slow growth of the Rayleigh-Plateau instability in aqueous two phase systems. Biomicrofluidics, 6(2), p.022007. Giselbrecht, S. et al., 2006. 3D tissue culture substrates produced by microthermoforming of pre-processed polymer films. Biomedical Microdevices, 8(3), pp.191–199.
  • 23. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 23 Hu, Y. et al., 2012. Shape controllable microgel particles prepared by microfluidic combining external ionic crosslinking. Biomicrofluidics, 6(2). Huang, K.-S., Lai, T.-H. & Lin, Y.-C., 2006. Manipulating the generation of Ca-alginate microspheres using microfluidic channels as a carrier of gold nanoparticles. Lab on a Chip, 6(7), pp.954–957. Hulme, E.S., Shevkoplyas, S.S. & Whitesides, G.M., 2009. Incorporation of prefabricated screw, pneumatic, and solenoid valves into microfluidic devices. Lab on a Chip, 9(1), p.79. Jo, B.-H. et al., 2000. Three-Dimensional Micro-Channel Fabrication inPolydimethylsiloxane (PDMS) Elastomer. Journal of Microelectromechanical Systems, 9(1), pp.76–81. Martinez, C.J. et al., 2012. A Microfluidic Approach to Encapsulate Living Cells in Uniform Alginate Hydrogel Microparticles. Macromolecular Bioscience, 12(7), pp.946–951. Martynova, L. et al., 1997. Fabrication of Plastic Microfluid Channels by Imprinting Methods. Analytical Chemistry, 69(23), pp.4783–4789. McCormick, R.M. et al., 1997. Microchannel Electrophoretic Separations of DNA in Injection-Molded Plastic Substrates. Analytical Chemistry, 69(14), pp.2626–2630. McDonald, J.C. & Whitesides, G.M., 2002. Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices. Accounts of Chemical Research, 35(7), pp.491–499. McDonald, J.C. et al., 2000. Fabrication of microfluidic systems in poly(dimethylsiloxane). Electrophoresis, 27(1), pp.27–40. MicroChem, 2006. SU-8 2000 Permanent Epoxy Negative Photoresist. pp.1–5. Nie, Z. et al., 2008. Emulsification in a microfluidic flow-focusing device: effect of the viscosities of the liquids. Microfluidics and Nanofluidics, 5(5), pp.585–594. Nunes, J.K. et al., 2013. Dripping and jetting in microfluidic multiphase flows applied to particle and fibre synthesis. Journal of Physics D: Applied Physics, 46(11). Romoli, L., Tantussi, G. & Dini, G., 2011. Optics and Lasers in Engineering. Optics and Lasers in Engineering, 49(3), pp.419–427. Sigma-Aldrich, 2011. Product Specification: Mineral Oil - Light Oil (neat), BioReagent. pp.1–1. Stone, H.A. & Kim, S., 2001. Microfluidics: Basic Issues, Applications, and Challenges. AIChE Journal, 47, pp.1–5. Stone, H.A., Stroock, A.D. & Ajdari, A., 2004. Engineering Flows in Small Devices. Annual Review of Fluid Mechanics, 36(1), pp.381–411. Tang, S.K.Y. & Whitesides, G.M., 2009. Basic Microfluidic and Soft Lithographic Techniques. Optofluidics: Fundamentals, Devices, and Applications, pp.7–31. Tsao, C.-W. & DeVoe, D.L., 2008. Bonding of thermoplastic polymer microfluidics. Microfluidics and Nanofluidics, 6(1), pp.1–16. Unger, M.A., 2000. Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography. Science, 288(5463), pp.113–116.
  • 24. Design and Fabrication of Microfluidic Flow Focusing Devices for Tissue Engineering Applications 24 Wang, J.-H. & Lee, G.-B., 2013. Formation of Tunable, Emulsion Micro-Droplets Utilizing Flow-Focusing Channels and a Normally-Closed Micro-Valve. Micromachines, 4(3), pp.306–320. Weibel, D.B. & Whitesides, G.M., 2006. Applications of Microfluidics in Chemical Biology. Current Opinion in Chemical Biology, 10(6), pp.584–591. White, F.M., 2010. Fluid Mechanics 7 ed., New York: McGraw-HIll. Whitesides, G.M., 2006. The origins and the future of microfluidics. Nature, 442(7101), pp.368–373. Whitesides, G.M. & Stroock, A.D., 2001. Flexible Methods for Microfluidics. Physics Today, pp.1–7. Xu, J. et al., 2000. Room-Temperature Imprinting Method for Plastic Microchannel Fabrication. Analytical Chemistry, 72(8), pp.1930–1933. Xu, S. et al., 2005. Generation of Monodisperse Particles by Using Microfluidics: Control over Size, Shape, and Composition. Angewandte Chemie International Edition, 44(5), pp.724–728.