SlideShare a Scribd company logo
1 of 6
Power system protection
Power system protection is a branch of electrical engineering that deals
with the protection of electrical equipment (or component) in a power
system network by removing the faulty part.
Power system protection deals with protecting electrical power systems
from faults by disconnecting faulty components from the rest of the
network. Power system protection is a branch of electrical engineering.
For example, a tree falling or touching an overhead transmission line
may cause a fault. There will be overloading of a motor due to worn out
of the bearing. A lightning strike on the overhead insulator can cause
insulation failure. Pollution may result in degradation in the performance
of insulators which may lead to a breakdown. Under frequency or over
frequency of an alternator may result in mechanical damage to its
turbine requiring tripping of an alternator. Even otherwise, the low-
frequency operation willreduce the life of a turbine, and hence it should
be avoided.
Protective systems disconnect the faulty part of the system and ensure
that the rest of the system is still powered, and protect the system from
further damage caused by the fault. In order to generate, transmit, and
distribute power with the least amount of interruptions and restoration
time, it is extremely important to make use of protection systems. There
is no doubt that protective systems are very important in order to
minimize the negative effects of faults, which, otherwise, can shut down
the whole system. Hence there is a need of protective system.
Function of protective system
The function of the protective system is to protect the system from
abnormal conditions and faults by isolating the faulty element as quickly
as possible. This will ensure the working of a healthy section of the
network. In short, the function of a protective system is as follows.
1. To maintain continuity of supply by safeguarding the entire system.
2. It minimizes damage and repair costs.
3. The safety of personnel must be ensured.
Components of protective system
A protection system consists of Current & Voltage Transformers,
protective relays, circuit breakers, and batteries.
1. Current transformers (CTs) & Potential Transformers (PTs): The
purpose of these transformers is to reduce the current and voltage so
that it could be used by relays for operation.
2. Protective Relays: The purpose of relays is to detect the fault and
initiate a trip sequence when an electrical quantity (example, voltage,
current, frequency, phase-angle, etc.) goes beyond the normal range.
Hence it will send a command to the circuit breaker to disconnect the
faulty part.
3. Circuit Breakers: The purpose of the circuit breakers is to operate on
the trip sequence initiated by the relays in order to open the circuit.
4. Batteries: The batteries are used as back up power supply in the event
of mains supply failure.
Zones of Protection in Power
System
A power system deals with generation, transmission, and distribution of
electrical power. Transformers, generators, bus bars, transmission &
distribution lines, circuit breakers, etc. are the elements or equipment of
a power system. Each element or equipment of the power system has its
own protective scheme. For example, transformer protection, generator
protection, bus bar protection, transmission line protection, etc. In this
way, a power system is divided into several protection zones. We study
the topic “zones of protection in power system” under the power
system protection.
A protective zone refers to a zone established around each system
element. Any fault occurring within a protective zone will cause the relays
to trip, which will open all the circuit breakers within that zone.
One or at most two elements of a power system are covered by a
protective zone. The protective zones are planned in such a way that
they cover the entire power system collectively, no portion of the power
system will be left out of protection. Figure 1 illustrates the various
protective zones of a typical power system.
Primary and Backup Protection in
Power System
n the previous article on “zones of protection in power system“, we see
that in order to ensure the safety of the power system, it is divided into
different zones. For each zone, there is an appropriate protective
scheme. In this article, we will learn about two types of protection in a
power system i.e. primary protection and back up protection.
Primary protection
The relays used in primary protection are called primary relays. The
primary relays of a zone are responsible for isolating the faulty
component in the event of a fault occurring in that zone. The primary
relay serves as the first line of defense. If the primary relay fails to
operate then back up protection is used to isolate the faulty component
from the system.
Back up protection
When the relay used in primary protection fails to operate then back up
protection is used to clear the fault. The relays used in back up
protection are called back up relays. It is important to note that backup
relays are independent of factors that might cause primary relays to fail
to operate. In order to give the primary relay sufficient time to operate, a
backup relay operates after a time delay. In the event that a back up
relay is operated, a large part of the electrical system will be
disconnected from the local power source and it cannot be avoided. The
back up relay serves as the second line of defense.
Types of back up protection
There are three types of back up protection i.e.
1. Remote back up
2. Relay back up
3. Breaker back up
1. Remote back up
As the name implies, there is a backup relay located at a nearby station.
The function of remote back up is to back up the primary protective
scheme (equipment such as relays, circuit breaker, CT, VT, bus bar, etc.) in
case of a failure of the primary protective scheme. It’s the most cost-
effective and easiest type of back up protection. This is a widely used
backup protection system for transmission lines.
2. Relay back up
In this scenario, an additional relay is used to provide backup protection
in the form of a local backup. When the primary relay fails, the additional
relay trips the same circuit breaker, and this operation occurs
immediately. It is desirable that additional relays operate according to
different principles than the primary protection. The additional relays
should be powered by separate current transformers and potential
transformers. The relay back up protection is costly. The relay back up
protection is recommended in situations where a remote backup is not
feasible.
3. Breaker back up
This serves also as a backup on a local level similar to relay back up.
Generally, this type of backup is utilized for bus bars that are connected
to a number of circuit breakers. In the event that a protective relay
operates in response to a fault, but the circuit breaker does not trip, it is
treated as a bus bar fault. This is the case when it is necessary to trip all
other circuit breakers within the bus bar. If the appropriate circuit
breaker fails to trip in the specified time period after its trip coil is
energized, the main relay closes the contact of a back-up relay, which
trips all other circuit breakers on the bus.
Current Limiting Reactor
A current limiting reactors is also called as series reactors. It is an inductive coil having large
inductive reactance compared to the resistance and is used to limit the short circuit current during
fault conditions. These reactors are connected in feeders and ties, in generator leads and between
the bus sections to reduce the magnitude of the short circuit current. The reactor allow free
interchange of power under normal condition. however during fault condition the disturbance is
confined to only faulty location. As the resistance of the reactors are small compared to reactance
the efficiency of the system is not affected much Short circuit current is reduced by an increase
in the reactance of the system. Short circuit current depends on the generating capacity, voltage
at the fault point and the total reactance between the generating point and the fault location.
Breaking capacity of the circuit breaker depends on the magnitude of the fault current. If the
fault current is beyond the designed limit of the breaking capacity of the breaker, the fault cannot
be extinguish. Therefore in large interconnected power system large number of generators and
motors feed the fault on occurrence of the fault. Therefore at times the magnitude of the short
circuit current exceeds the breaking capacity of the breaker. Therefore it is necessary to limit the
fault current by some means. By including a reactor or few reactors at some strategic locations,
short circuit currents at different points can be reduced. The current limiting reactor is an
inductive coil having large inductive reactances in comparison to their resistance and is used for
limiting short circuit currents during fault conditions. Current-voltage reactors also reduced the
voltage disturbances on the rest of the system. It is installed in feeders and ties, in generators
leads, and between bus sections, for reducing the magnitude of short circuit currents and the
effect of the respective voltage disturbance.Current reactor allows free interchange of power
under normal condition, but when the fault occurs the disturbance is restricted by the current
reactor to the faulty section. As the resistance of the system is very small as compared to their
reactance. Hence, the efficiency of the system is not much affected.

More Related Content

Similar to Protection in Power System.docx

Switch gear and protection
Switch gear and protectionSwitch gear and protection
Switch gear and protectionDinesh Sharma
 
Relay coordination
Relay coordinationRelay coordination
Relay coordinationD Målîk
 
EE6702 Protection and Switchgear
EE6702 Protection and SwitchgearEE6702 Protection and Switchgear
EE6702 Protection and Switchgearrmkceteee
 
Power system protection seminar report
Power system protection seminar reportPower system protection seminar report
Power system protection seminar reportRahul Aman
 
INDUSTRIAL TRAINING:SWITCHYARD STUDY
INDUSTRIAL TRAINING:SWITCHYARD STUDYINDUSTRIAL TRAINING:SWITCHYARD STUDY
INDUSTRIAL TRAINING:SWITCHYARD STUDYtarun1504
 
lecture1423723756.pdf
lecture1423723756.pdflecture1423723756.pdf
lecture1423723756.pdfssuser564db8
 
Unit 03 Protective relays
Unit  03 Protective relaysUnit  03 Protective relays
Unit 03 Protective relaysPremanandDesai
 
Substation protection devices
Substation protection devicesSubstation protection devices
Substation protection devicesRahul Aman
 
Switchgears and protection devices
Switchgears and protection devicesSwitchgears and protection devices
Switchgears and protection devicesManojkarader
 
Introduction to power system protection
Introduction to power system protectionIntroduction to power system protection
Introduction to power system protectionSaifUrrehman183
 
Substation Protection Systems Presentation Group II.pptx
Substation Protection Systems Presentation Group II.pptxSubstation Protection Systems Presentation Group II.pptx
Substation Protection Systems Presentation Group II.pptxIntishar Rahman
 

Similar to Protection in Power System.docx (20)

Adaptive Relaying,Report
Adaptive Relaying,ReportAdaptive Relaying,Report
Adaptive Relaying,Report
 
Switch gear and protection
Switch gear and protectionSwitch gear and protection
Switch gear and protection
 
Protective relaying
Protective relayingProtective relaying
Protective relaying
 
Relay coordination
Relay coordinationRelay coordination
Relay coordination
 
EE6702 Protection and Switchgear
EE6702 Protection and SwitchgearEE6702 Protection and Switchgear
EE6702 Protection and Switchgear
 
Types of relay
Types of relayTypes of relay
Types of relay
 
Relays
RelaysRelays
Relays
 
Power system protection seminar report
Power system protection seminar reportPower system protection seminar report
Power system protection seminar report
 
INDUSTRIAL TRAINING:SWITCHYARD STUDY
INDUSTRIAL TRAINING:SWITCHYARD STUDYINDUSTRIAL TRAINING:SWITCHYARD STUDY
INDUSTRIAL TRAINING:SWITCHYARD STUDY
 
lecture1423723756.pdf
lecture1423723756.pdflecture1423723756.pdf
lecture1423723756.pdf
 
Protective relay.pptx
Protective relay.pptxProtective relay.pptx
Protective relay.pptx
 
Protective Relay
Protective RelayProtective Relay
Protective Relay
 
Unit 03 Protective relays
Unit  03 Protective relaysUnit  03 Protective relays
Unit 03 Protective relays
 
Substation protection devices
Substation protection devicesSubstation protection devices
Substation protection devices
 
Switchgears and protection devices
Switchgears and protection devicesSwitchgears and protection devices
Switchgears and protection devices
 
Introduction to power system protection
Introduction to power system protectionIntroduction to power system protection
Introduction to power system protection
 
D04522631
D04522631D04522631
D04522631
 
Substation Protection Systems Presentation Group II.pptx
Substation Protection Systems Presentation Group II.pptxSubstation Protection Systems Presentation Group II.pptx
Substation Protection Systems Presentation Group II.pptx
 
Et601 chapter1 ayu
Et601  chapter1 ayuEt601  chapter1 ayu
Et601 chapter1 ayu
 
What's short circuit level
What's short circuit levelWhat's short circuit level
What's short circuit level
 

Recently uploaded

Crayon Activity Handout For the Crayon A
Crayon Activity Handout For the Crayon ACrayon Activity Handout For the Crayon A
Crayon Activity Handout For the Crayon AUnboundStockton
 
Types of Journalistic Writing Grade 8.pptx
Types of Journalistic Writing Grade 8.pptxTypes of Journalistic Writing Grade 8.pptx
Types of Journalistic Writing Grade 8.pptxEyham Joco
 
internship ppt on smartinternz platform as salesforce developer
internship ppt on smartinternz platform as salesforce developerinternship ppt on smartinternz platform as salesforce developer
internship ppt on smartinternz platform as salesforce developerunnathinaik
 
EPANDING THE CONTENT OF AN OUTLINE using notes.pptx
EPANDING THE CONTENT OF AN OUTLINE using notes.pptxEPANDING THE CONTENT OF AN OUTLINE using notes.pptx
EPANDING THE CONTENT OF AN OUTLINE using notes.pptxRaymartEstabillo3
 
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptx
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptxPOINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptx
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptxSayali Powar
 
Presiding Officer Training module 2024 lok sabha elections
Presiding Officer Training module 2024 lok sabha electionsPresiding Officer Training module 2024 lok sabha elections
Presiding Officer Training module 2024 lok sabha electionsanshu789521
 
Proudly South Africa powerpoint Thorisha.pptx
Proudly South Africa powerpoint Thorisha.pptxProudly South Africa powerpoint Thorisha.pptx
Proudly South Africa powerpoint Thorisha.pptxthorishapillay1
 
Full Stack Web Development Course for Beginners
Full Stack Web Development Course  for BeginnersFull Stack Web Development Course  for Beginners
Full Stack Web Development Course for BeginnersSabitha Banu
 
Interactive Powerpoint_How to Master effective communication
Interactive Powerpoint_How to Master effective communicationInteractive Powerpoint_How to Master effective communication
Interactive Powerpoint_How to Master effective communicationnomboosow
 
KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...
KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...
KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...M56BOOKSTORE PRODUCT/SERVICE
 
Painted Grey Ware.pptx, PGW Culture of India
Painted Grey Ware.pptx, PGW Culture of IndiaPainted Grey Ware.pptx, PGW Culture of India
Painted Grey Ware.pptx, PGW Culture of IndiaVirag Sontakke
 
Software Engineering Methodologies (overview)
Software Engineering Methodologies (overview)Software Engineering Methodologies (overview)
Software Engineering Methodologies (overview)eniolaolutunde
 
Final demo Grade 9 for demo Plan dessert.pptx
Final demo Grade 9 for demo Plan dessert.pptxFinal demo Grade 9 for demo Plan dessert.pptx
Final demo Grade 9 for demo Plan dessert.pptxAvyJaneVismanos
 
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptx
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptxECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptx
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptxiammrhaywood
 
भारत-रोम व्यापार.pptx, Indo-Roman Trade,
भारत-रोम व्यापार.pptx, Indo-Roman Trade,भारत-रोम व्यापार.pptx, Indo-Roman Trade,
भारत-रोम व्यापार.pptx, Indo-Roman Trade,Virag Sontakke
 
Pharmacognosy Flower 3. Compositae 2023.pdf
Pharmacognosy Flower 3. Compositae 2023.pdfPharmacognosy Flower 3. Compositae 2023.pdf
Pharmacognosy Flower 3. Compositae 2023.pdfMahmoud M. Sallam
 
DATA STRUCTURE AND ALGORITHM for beginners
DATA STRUCTURE AND ALGORITHM for beginnersDATA STRUCTURE AND ALGORITHM for beginners
DATA STRUCTURE AND ALGORITHM for beginnersSabitha Banu
 

Recently uploaded (20)

Crayon Activity Handout For the Crayon A
Crayon Activity Handout For the Crayon ACrayon Activity Handout For the Crayon A
Crayon Activity Handout For the Crayon A
 
Types of Journalistic Writing Grade 8.pptx
Types of Journalistic Writing Grade 8.pptxTypes of Journalistic Writing Grade 8.pptx
Types of Journalistic Writing Grade 8.pptx
 
internship ppt on smartinternz platform as salesforce developer
internship ppt on smartinternz platform as salesforce developerinternship ppt on smartinternz platform as salesforce developer
internship ppt on smartinternz platform as salesforce developer
 
EPANDING THE CONTENT OF AN OUTLINE using notes.pptx
EPANDING THE CONTENT OF AN OUTLINE using notes.pptxEPANDING THE CONTENT OF AN OUTLINE using notes.pptx
EPANDING THE CONTENT OF AN OUTLINE using notes.pptx
 
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptx
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptxPOINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptx
POINT- BIOCHEMISTRY SEM 2 ENZYMES UNIT 5.pptx
 
Presiding Officer Training module 2024 lok sabha elections
Presiding Officer Training module 2024 lok sabha electionsPresiding Officer Training module 2024 lok sabha elections
Presiding Officer Training module 2024 lok sabha elections
 
Proudly South Africa powerpoint Thorisha.pptx
Proudly South Africa powerpoint Thorisha.pptxProudly South Africa powerpoint Thorisha.pptx
Proudly South Africa powerpoint Thorisha.pptx
 
TataKelola dan KamSiber Kecerdasan Buatan v022.pdf
TataKelola dan KamSiber Kecerdasan Buatan v022.pdfTataKelola dan KamSiber Kecerdasan Buatan v022.pdf
TataKelola dan KamSiber Kecerdasan Buatan v022.pdf
 
Full Stack Web Development Course for Beginners
Full Stack Web Development Course  for BeginnersFull Stack Web Development Course  for Beginners
Full Stack Web Development Course for Beginners
 
Interactive Powerpoint_How to Master effective communication
Interactive Powerpoint_How to Master effective communicationInteractive Powerpoint_How to Master effective communication
Interactive Powerpoint_How to Master effective communication
 
KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...
KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...
KSHARA STURA .pptx---KSHARA KARMA THERAPY (CAUSTIC THERAPY)————IMP.OF KSHARA ...
 
Painted Grey Ware.pptx, PGW Culture of India
Painted Grey Ware.pptx, PGW Culture of IndiaPainted Grey Ware.pptx, PGW Culture of India
Painted Grey Ware.pptx, PGW Culture of India
 
ESSENTIAL of (CS/IT/IS) class 06 (database)
ESSENTIAL of (CS/IT/IS) class 06 (database)ESSENTIAL of (CS/IT/IS) class 06 (database)
ESSENTIAL of (CS/IT/IS) class 06 (database)
 
Software Engineering Methodologies (overview)
Software Engineering Methodologies (overview)Software Engineering Methodologies (overview)
Software Engineering Methodologies (overview)
 
Final demo Grade 9 for demo Plan dessert.pptx
Final demo Grade 9 for demo Plan dessert.pptxFinal demo Grade 9 for demo Plan dessert.pptx
Final demo Grade 9 for demo Plan dessert.pptx
 
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptx
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptxECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptx
ECONOMIC CONTEXT - PAPER 1 Q3: NEWSPAPERS.pptx
 
भारत-रोम व्यापार.pptx, Indo-Roman Trade,
भारत-रोम व्यापार.pptx, Indo-Roman Trade,भारत-रोम व्यापार.pptx, Indo-Roman Trade,
भारत-रोम व्यापार.pptx, Indo-Roman Trade,
 
9953330565 Low Rate Call Girls In Rohini Delhi NCR
9953330565 Low Rate Call Girls In Rohini  Delhi NCR9953330565 Low Rate Call Girls In Rohini  Delhi NCR
9953330565 Low Rate Call Girls In Rohini Delhi NCR
 
Pharmacognosy Flower 3. Compositae 2023.pdf
Pharmacognosy Flower 3. Compositae 2023.pdfPharmacognosy Flower 3. Compositae 2023.pdf
Pharmacognosy Flower 3. Compositae 2023.pdf
 
DATA STRUCTURE AND ALGORITHM for beginners
DATA STRUCTURE AND ALGORITHM for beginnersDATA STRUCTURE AND ALGORITHM for beginners
DATA STRUCTURE AND ALGORITHM for beginners
 

Protection in Power System.docx

  • 1. Power system protection Power system protection is a branch of electrical engineering that deals with the protection of electrical equipment (or component) in a power system network by removing the faulty part. Power system protection deals with protecting electrical power systems from faults by disconnecting faulty components from the rest of the network. Power system protection is a branch of electrical engineering. For example, a tree falling or touching an overhead transmission line may cause a fault. There will be overloading of a motor due to worn out of the bearing. A lightning strike on the overhead insulator can cause insulation failure. Pollution may result in degradation in the performance of insulators which may lead to a breakdown. Under frequency or over frequency of an alternator may result in mechanical damage to its turbine requiring tripping of an alternator. Even otherwise, the low- frequency operation willreduce the life of a turbine, and hence it should be avoided. Protective systems disconnect the faulty part of the system and ensure that the rest of the system is still powered, and protect the system from further damage caused by the fault. In order to generate, transmit, and distribute power with the least amount of interruptions and restoration time, it is extremely important to make use of protection systems. There is no doubt that protective systems are very important in order to minimize the negative effects of faults, which, otherwise, can shut down the whole system. Hence there is a need of protective system. Function of protective system The function of the protective system is to protect the system from abnormal conditions and faults by isolating the faulty element as quickly as possible. This will ensure the working of a healthy section of the network. In short, the function of a protective system is as follows. 1. To maintain continuity of supply by safeguarding the entire system.
  • 2. 2. It minimizes damage and repair costs. 3. The safety of personnel must be ensured. Components of protective system A protection system consists of Current & Voltage Transformers, protective relays, circuit breakers, and batteries. 1. Current transformers (CTs) & Potential Transformers (PTs): The purpose of these transformers is to reduce the current and voltage so that it could be used by relays for operation. 2. Protective Relays: The purpose of relays is to detect the fault and initiate a trip sequence when an electrical quantity (example, voltage, current, frequency, phase-angle, etc.) goes beyond the normal range. Hence it will send a command to the circuit breaker to disconnect the faulty part. 3. Circuit Breakers: The purpose of the circuit breakers is to operate on the trip sequence initiated by the relays in order to open the circuit. 4. Batteries: The batteries are used as back up power supply in the event of mains supply failure. Zones of Protection in Power System A power system deals with generation, transmission, and distribution of electrical power. Transformers, generators, bus bars, transmission & distribution lines, circuit breakers, etc. are the elements or equipment of a power system. Each element or equipment of the power system has its own protective scheme. For example, transformer protection, generator protection, bus bar protection, transmission line protection, etc. In this
  • 3. way, a power system is divided into several protection zones. We study the topic “zones of protection in power system” under the power system protection. A protective zone refers to a zone established around each system element. Any fault occurring within a protective zone will cause the relays to trip, which will open all the circuit breakers within that zone. One or at most two elements of a power system are covered by a protective zone. The protective zones are planned in such a way that they cover the entire power system collectively, no portion of the power system will be left out of protection. Figure 1 illustrates the various protective zones of a typical power system.
  • 4. Primary and Backup Protection in Power System n the previous article on “zones of protection in power system“, we see that in order to ensure the safety of the power system, it is divided into different zones. For each zone, there is an appropriate protective scheme. In this article, we will learn about two types of protection in a power system i.e. primary protection and back up protection. Primary protection The relays used in primary protection are called primary relays. The primary relays of a zone are responsible for isolating the faulty component in the event of a fault occurring in that zone. The primary relay serves as the first line of defense. If the primary relay fails to operate then back up protection is used to isolate the faulty component from the system. Back up protection When the relay used in primary protection fails to operate then back up protection is used to clear the fault. The relays used in back up protection are called back up relays. It is important to note that backup relays are independent of factors that might cause primary relays to fail to operate. In order to give the primary relay sufficient time to operate, a backup relay operates after a time delay. In the event that a back up relay is operated, a large part of the electrical system will be disconnected from the local power source and it cannot be avoided. The back up relay serves as the second line of defense. Types of back up protection There are three types of back up protection i.e.
  • 5. 1. Remote back up 2. Relay back up 3. Breaker back up 1. Remote back up As the name implies, there is a backup relay located at a nearby station. The function of remote back up is to back up the primary protective scheme (equipment such as relays, circuit breaker, CT, VT, bus bar, etc.) in case of a failure of the primary protective scheme. It’s the most cost- effective and easiest type of back up protection. This is a widely used backup protection system for transmission lines. 2. Relay back up In this scenario, an additional relay is used to provide backup protection in the form of a local backup. When the primary relay fails, the additional relay trips the same circuit breaker, and this operation occurs immediately. It is desirable that additional relays operate according to different principles than the primary protection. The additional relays should be powered by separate current transformers and potential transformers. The relay back up protection is costly. The relay back up protection is recommended in situations where a remote backup is not feasible. 3. Breaker back up This serves also as a backup on a local level similar to relay back up. Generally, this type of backup is utilized for bus bars that are connected to a number of circuit breakers. In the event that a protective relay operates in response to a fault, but the circuit breaker does not trip, it is treated as a bus bar fault. This is the case when it is necessary to trip all other circuit breakers within the bus bar. If the appropriate circuit breaker fails to trip in the specified time period after its trip coil is energized, the main relay closes the contact of a back-up relay, which trips all other circuit breakers on the bus. Current Limiting Reactor
  • 6. A current limiting reactors is also called as series reactors. It is an inductive coil having large inductive reactance compared to the resistance and is used to limit the short circuit current during fault conditions. These reactors are connected in feeders and ties, in generator leads and between the bus sections to reduce the magnitude of the short circuit current. The reactor allow free interchange of power under normal condition. however during fault condition the disturbance is confined to only faulty location. As the resistance of the reactors are small compared to reactance the efficiency of the system is not affected much Short circuit current is reduced by an increase in the reactance of the system. Short circuit current depends on the generating capacity, voltage at the fault point and the total reactance between the generating point and the fault location. Breaking capacity of the circuit breaker depends on the magnitude of the fault current. If the fault current is beyond the designed limit of the breaking capacity of the breaker, the fault cannot be extinguish. Therefore in large interconnected power system large number of generators and motors feed the fault on occurrence of the fault. Therefore at times the magnitude of the short circuit current exceeds the breaking capacity of the breaker. Therefore it is necessary to limit the fault current by some means. By including a reactor or few reactors at some strategic locations, short circuit currents at different points can be reduced. The current limiting reactor is an inductive coil having large inductive reactances in comparison to their resistance and is used for limiting short circuit currents during fault conditions. Current-voltage reactors also reduced the voltage disturbances on the rest of the system. It is installed in feeders and ties, in generators leads, and between bus sections, for reducing the magnitude of short circuit currents and the effect of the respective voltage disturbance.Current reactor allows free interchange of power under normal condition, but when the fault occurs the disturbance is restricted by the current reactor to the faulty section. As the resistance of the system is very small as compared to their reactance. Hence, the efficiency of the system is not much affected.