2. FORM
FOR-TEC-101 Rev.: A
Page 1 of 3
FLOW AND PRESSURE STUDY REPORT
DATE 16/03/2017 TRIAL # HDP-17-002 MOLD Spiral 1 mm
MATERIAL
FAMILY PEEK SUPPLIER VICTREX
TRADE NAME VICTREX® PEEK GRADE 450CA30
PICTURES OF INJECTED SAMPLES
T=190°C - Conventional - WITHOUT (1000 Bar) T= 250°C - RocTool - WITH (1000 Bar)
15001000
ROCTOOL TECHNOLOGY IMPROVEMENT VERSUS CONVENTIONAL TECHNOLOGY
Flow length improvement
Pressure (Bar)
210°C
FLOW LENGTH MEASUREMENT AT DIFFERENT IMM PRESSURE
17,4%
18,4%
27,4%
10,0%
17,0%
29,0%
230°C
250°C
500
_
_
_
Sensor 1
Sensor 1
Sensor 2
3. Sensor 1 Sensor 2 Sensor 1 Sensor 2 Sensor 1 Sensor 2 Sensor 1 Sensor 2 Sensor 1 Sensor 2 Sensor 1 Sensor 2
188,6 0 592,2 187,6 883,2 382,2 120,8 0 553,2 276,6 832,2 521,2
Page 2 of 3
FLOW AND PRESSURE STUDY REPORT
FORM
FOR-TEC-101 Rev.: A
DATE 11/04/2017 TRIAL # HDP-17-002 MOLD Spiral 1.5 mm
MATERIAL
FAMILY PEEK SUPPLIER VICTREX
TRADE NAME
PICTURES OF INJECTED SAMPLES
T=190°C - Conventional - WITHOUT (1000 Bar) T= 250°C - RocTool - WITH (1000 Bar)
VICTREX® PEEK GRADE 450CA30
5,6%
Pressure (Bar) 500
ROCTOOL TECHNOLOGY IMPROVEMENT VERSUS CONVENTIONAL TECHNOLOGY
Flow length improvement
Pressure Drop (%) 100,00% 68,32% 56,73% 100,00%
1000 1500
Sensors
Mold Pressure Avg
Pressure (Bar) 500 1000 1500 500
CONVENTIONAL TECHNOLOGY (190°C) ROCTOOL TECHNOLOGY (250°C)
PRESSURE DROP BETWEEN THE TWO PRESSURE SENSORS
-1,8% 4,2%
250°C 10,7% 14,3% 17,4%
1000 1500
210°C 10,7% 6,1% 4,4%
50,00% 37,37%
FLOW LENGTH MEASUREMENT AT DIFFERENT IMM PRESSURE
230°C
Sensor 1
Sensor 2
Sensor 1
Sensor 2
4. FORM
FOR-TEC-101 Rev.: A
Page 3 of 3
FLOW AND PRESSURE STUDY REPORT
DATE 11/04/2017 TRIAL # HDP-17-002 MOLD Spiral
MATERIAL
FAMILY PEEK SUPPLIER VICTREX
450CA30
Flow Length improvement vs Injection Pressure in function of Mold Temperature/Mold Thickness
TRADE NAME VICTREX® PEEK GRADE
The graph above shows a flow length for the 2 thicknesses at
two temperature (190°C and 250°C). By comparing these
curves, a significant reduction in thickness can be observed.
Also, the following diagram shows the pressure drop
measured between the two sensors for 1,5 mm of thickness
at 1000 bars of injection pressure. The reduction of pressure
drop in the cavity is important up to 26%.
GLOBAL COMMENTS & RECOMMENDATIONS
The HD Plastics™ characterization trials showns a significant flow length and pressure drop improvment. The optimum mold
temperature is 250°C regarding to the trials performed with this material. We obtain the longest flow with an important
reduction of the pressure drop compared to the conventional mold temperature.
Note : All the injection trials and the pressure measurements were carried out according to the protocol defined by RocTool (injection process, 2 heating sides,
cold sprue, mold design).
All pressure data are measured using eDart system (RJG).
Pressure Drop between the 2 Sensors vs Mold Thickness at Injection
Pressure = 1000 Bars
Results Evaluations