PASSIVE VS ACTIVE SAMPLING FOR SENSOR-BASED
AMBIENT AIR QUALITY MONITORING
2. AMBIENT AIR MONITORING DEVICES:
OR
REFERENCE STATION LOW-COST SENSOR-
BASED
Low-Cost
Affordable
Compact Device
Easy to fit
Sensitive to External Environment.
(Temperature, Humidity, Wind Speed, Dust)
Data Accuracy decreases with time.
INTRODUCTION
© Oizom Instruments PVT LTD
www.oizom.com | hello@oizom.com
Passive Vs Active Sampling For Sensor-based Ambient Air Quality Monitoring
3. - Effect of Temperature and
Humidity on sensor depends on
the extremity of the conditions
and time duration of exposure.
- Both positive and negative
effects are observed with
increase in temperature.
- Particulate Matter sensors are
highly sensitive to Relative
Humidity.
- Temperature and Relative
Humidity are negatively
correlated.
TEMPERATURE:
Photoionization Detector (PID)
Electrochemical Sensors
Nondispersive Infrared (NDIR) (no effect)
RELATIVE HUMIDITY:
PM2.5 : Underestimated
PM10 : Overestimated
RH > 70-80% Mass Concentration
Particle Number
© Oizom Instruments PVT LTD
www.oizom.com | hello@oizom.com
Passive Vs Active Sampling For Sensor-based Ambient Air Quality MonitoringFACTORS AFFECTING SENSORS
4. DUST
- High dust concentration PM10 (>300-400 μg/m3 )
causes dust deposition on the sensors.
- RH > 85% : PM agglomerates and gets stuck on the
sensors.
- Construction and Mining sites.
- Dust laden roads.
- Drilling sites.
Erroneous Results Frequent
Maintenance &
Replacement
© Oizom Instruments PVT LTD
www.oizom.com | hello@oizom.com
Passive Vs Active Sampling For Sensor-based Ambient Air Quality MonitoringFACTORS AFFECTING SENSORS
5. - Transport and Dispersion of Air pollutants is affected. (PM2.5, PM10).
- Diffusion rates and kinetics of redox reactions are affected that generates
erroneous results.
WIND SPEED
Turbulence, Wind gusts, High Wind Speed affects sensor
performance.
© Oizom Instruments PVT LTD
www.oizom.com | hello@oizom.com
Passive Vs Active Sampling For Sensor-based Ambient Air Quality MonitoringFACTORS AFFECTING SENSORS
6. High Volume Air Sampler
(First Generation)
Continuous Ambient Air Quality Monitoring
Stations - CAAQMS
(Second Generation)
Low-Cost Sensors
(Third Generation)
Active Sampling Devices Passive Sampling Devices
© Oizom Instruments PVT LTD
www.oizom.com | hello@oizom.com
Passive Vs Active Sampling For Sensor-based Ambient Air Quality MonitoringCLASSIFICATION
7. Exposed
Sensors
- Sensor are directly exposed to the Environment.
- Sensor gets highly affected by:
Used in conventional sensor-based systems.
- Reduced Data Accuracy
- Frequent Maintenance and Replacement.
- Reduced Working Life.
TEMPERATURE RELATIVE
HUMIDITY
HEAVY
DUST
HIGH
SPEED
© Oizom Instruments PVT LTD
www.oizom.com | hello@oizom.com
Passive Vs Active Sampling For Sensor-based Ambient Air Quality MonitoringPASSIVE DEVICES
8. Sensors are placed in an enclosed unit.
- The system draws in a specific volume of air
using a pump at a particular time interval.
- Not affected by Ambient Conditions.
© Oizom Instruments PVT LTD
www.oizom.com | hello@oizom.com
Passive Vs Active Sampling For Sensor-based Ambient Air Quality MonitoringACTIVE DEVICES
9. Parameter Passive Sampling Active Sampling
Sensor exposure to ambient
conditions
Yes No
Air sampling using a predefined
airflow
No Yes
Influence of temperature, humidity,
dust or wind on data
Yes No
Maintenance
Frequent due to reduced
working life of sensors
Minimal with quarterly
cleaning activity
On-site reference gas calibration No Yes
Collocation against reference-grade
systems with R2 >0.85
No Yes
© Oizom Instruments PVT LTD
www.oizom.com | hello@oizom.com
Passive Vs Active Sampling For Sensor-based Ambient Air Quality MonitoringCOMPARISON
10. E – BREATHING
TECHNOLOGY
(Active Sampling Based)
BIOMIMICRY OF THE
HUMAN LUNGS.
INHALES
(325ml air sample)
EXHALES
(325ml air sample)
ANALYZING USING DIFFERENT
SENSORS
Collocated against
Reference Stations
R2 > 0.85 – 0.9
No effect of External
Environmental Factors
Better Data Quality
(High Accuracy and Precision)
© Oizom Instruments PVT LTD
www.oizom.com | hello@oizom.com
Passive Vs Active Sampling For Sensor-based Ambient Air Quality MonitoringOIZOM’S OFFERING
11. Oizom has a wide range of sensor-based air quality monitoring systems for all kinds of applications which
provides real-time air quality monitoring data along with meteorological parameters. Deep machine
learning algorithms of Oizom ensure high data quality which gives more than 90% accurate data when
calibrated against the standard reference system.
© Oizom Instruments PVT LTD
www.oizom.com | hello@oizom.com
Passive Vs Active Sampling For Sensor-based Ambient Air Quality MonitoringOIZOM’S OFFERING
POLLUDRONE ™
Ambient Air Pollution
Monitoring System
ODOSENSE ™
Ambient Odour
Analyzer
DUSTROID ™
Ambient Dust
Monitor
WEATHERCOM ™
Automatic Weather Station
12. Oizom not only provides air quality monitoring but also offers comprehensive and scalable analytics. The data
sent by OIZOM’s sensors over the cloud is made actionable by performing advanced analytics. The data can be
published on various mediums like Web App, Mobile App, Display units, and can be further used in dispersion
modelling, emission inventory, and health exposure studies.
© Oizom Instruments PVT LTD
www.oizom.com | hello@oizom.com
Passive Vs Active Sampling For Sensor-based Ambient Air Quality MonitoringOIZOM’S OFFERING