1. Scale (@ A3)
Checked by
Drawn by
Date Project number
www.autodesk.com/revit
STATUS PURPOSE OF ISSUECODE SUITABILITY DESCRIPTION
DRWAING NUMBER REV
PROJECT CLIENT
SHEET
16/05/201409:05:27
ADJACENT BUILDING
Project Number
276CAB JYOTI PRASHAR
Issue Date
Author
Checker
A110
No. Description Date
ADJACENT BUILDING 1:200
2. -
-
--
-
-
- -
27
786
HILL
STREET
12 68
8
St John the
25
188
10
79.2m
14
to
18
LB
49 80
PO
66Shelter
63
FLEET ST
Hospital
26
Belgrade Theatre
(site of)
2
CORPORATION
STREET
PH
PH
190
ElSub
Sta
Lidice
Baptist's Church
77
to
117
(above)
4
79.6m
82 to 96
2
75
65
Bank
Club
(site of)
61
BO
ND
STREET
El Sub
Sta
Spon Gate
Hill Gate
Mercia
House
1to96
Post
Bablake
Boys'
Monument
Almshouse
Bonds Court
LB
TCBs
TCBs
TCB
Scale (@ A3)
Checked by
Drawn by
Date Project number
www.autodesk.com/revit
STATUS PURPOSE OF ISSUECODE SUITABILITY DESCRIPTION
DRWAING NUMBER REV
PROJECT CLIENT
SHEET
1 : 800
16/05/201409:07:46
SITE PLAN
Project Number
276CAB JYOTI PRASHAR
Issue Date
Author
Checker
A101
No. Description Date
1 : 800
Site
Bus stops in front of the
building is ideal for people
to get to one destination to
another. Bus stops could
result in traffic and due to it
be so close to the building
could be disadvantage
Trees are to be retained by the
Coventry City Council. Height are
about 15-20m
ADJACENT BUILDING
NEWLY BUILT COMMERCIAL
BUILDING FOR RETAIL
AND OFFICES
Pathway through the arcade
Hill street lies next to the
site and is quite with
limited traffic
NORTH
Fire exit for the building is
situated opposite side of
entrance
Any vehicle access possible is
only from service road
Sun rises in the East and sets in the West
Prevailing winds blow from
the South, South West and
West for a total of 55% of
the time
3. DW
REF.
UP
UP
1
2
3
4
5
6
7
A B C D E F G H I J
8
65 m²
703.8 SF
Reception Area
1
57 m²
618.3 SF
Loading Bay
5
29 m²
317.3 SF
Fire escape
7
240 m²
2583.8 SF
Cafe
9
58 m²
627.2 SF
Kitchen
6
157 m²
1693.2 SF
Retail
8
11 m²
118.7 SF
Ladies
3
11 m²
120.0 SF
Mens
4
16 m²
170.3 SF
Toilets
2
CURVED
GLAZED
ENTRANCE
ENTRANCE TO
RECEPTION
AREA
FIRE EXIT
ADJACENT BUILDING
ELEVATOR
Scale (@ A3)
Checked by
Drawn by
Date Project number
www.autodesk.com/revit
STATUS PURPOSE OF ISSUECODE SUITABILITY DESCRIPTION
DRWAING NUMBER REV
PROJECT CLIENT
SHEET
1 : 200
16/05/201409:01:16
FLOOR PLANS- GROUND
Project Number
276CAB JYOTI PRASHAR
Issue Date
Author
Checker
A108
No. Description Date
1 : 200
GROUND FLOOR PLAN
4. UP
UP
1
2
3
4
5
6
7
A B C D E F G H I J
8
65 m²
703.5 SF
Reception room
10
11 m²
119.3 SF
Ladies
11
12 m²
123.8 SF
Mens
12
16 m²
173.4 SF
Toilets
13
80 m²
861.5 SF
Board room
14
30 m²
317.6 SF
Fire escape
15
607 m²
6538.1 SF
Office space
16
Scale (@ A3)
Checked by
Drawn by
Date Project number
www.autodesk.com/revit
STATUS PURPOSE OF ISSUECODE SUITABILITY DESCRIPTION
DRWAING NUMBER REV
PROJECT CLIENT
SHEET
1 : 200
16/05/201409:01:46
FLOOR PLANS- FIRST
Project Number
276CAB JYOTI PRASHAR
Issue Date
Author
Checker
A109
No. Description Date
1 : 200
FIRST FLOOR PLAN
CURTAIN
WALLING
SYSTEM
ADJACENT BUILDING
ELEVATOR
SAME ARRANGEMENT ON SECOND AND THIRD FLOOR
5. ROOF
THIRD FLOOR
SECOND FLOOR
FIRST FLOOR
GROUND FLOOR
GROUND BEARING CONCRETE SLAB
Scale (@ A3)
Checked by
Drawn by
Date Project number
www.autodesk.com/revit
STATUS PURPOSE OF ISSUECODE SUITABILITY DESCRIPTION
DRWAING NUMBER REV
PROJECT CLIENT
SHEET
1 : 200
16/05/201408:59:41
ELEVATIONS
Project Number
276CAB JYOTI PRASHAR
Issue Date
Author
Checker
A105
No. Description Date
BACK 1:200
LEFT 1:200 FRONT 1:200
BRICKWORK
ENTRANCE TO RECEPTION AREA CURVED GLAZED ENTRANCE TO CAFE
6. Ground level
0
FIRST FLOOR PLAN
4000
1 2 3 4 5 6 7
SECOND FLOOR
PLAN
8000
THIRD FLOOR PLAN
12000
ROOF
16000
8
1
A101
1
A102
1
A103
Scale (@ A3)
Checked by
Drawn by
Date Project number
www.autodesk.com/revit
STATUS PURPOSE OF ISSUECODE SUITABILITY DESCRIPTION
DRWAING NUMBER REV
PROJECT CLIENT
SHEET
1 : 100
16/05/201408:58:57
DETAIL SECTION
Project Number
276CAB JYOTI PRASHAR
Issue Date
Author
Checker
A104
No. Description Date
1 : 100
DETAIL SECTION
1
Curtain walling
system
Stairs
access
from
reception
area
Elevator
Parapet Ground bearing slab
curved glazed
entrance
concrete columns
7. Screed Finish
Concrete slab
Insulation
Seperation Layer
DPM linked to DPC
Compacted sand
blinding
Well compacted
hardcore
Subsoil
Cavity fill below DPC
DPC min 150mm above
Perimeter insulation
Foundations to be 1:2:4 mix (cement, sharp sand, 20mm
aggregregate) with slump well
compacted and in layers and levelled. Drains passing through
foundations to be seperated
from concrete to allow movement.
Excavations are to be dug to a minimum depth of 1m and to atleast the depth of the existing
foundations and below the invert level of adjacent drains. Any trees, whether young, mature or removed
within the last 12 years, that are within 30m of the proposed site may effect the final depth of the foundation.
Final depths of excavations to be approved by a building control surveyor prior to placing concrete.
Brickwork
Blockwork
Scale (@ A3)
Checked by
Drawn by
Date Project number
www.autodesk.com/revit
STATUS PURPOSE OF ISSUECODE SUITABILITY DESCRIPTION
DRWAING NUMBER REV
PROJECT CLIENT
SHEET
1 : 5
16/05/201408:56:27
GROUND FLOOR
Project Number
276CAB JYOTI PRASHAR
Issue Date
Author
Checker
A101
No. Description Date
8. Mullion section of cladding system Block lining wall
Column of
structural frame
Structural floor
Stainless steel fixing bracket
Insulated panel
Neopreme seals
Insulated
curtain
wall infill
panel
Glazed
curtain
walling
section
Extruded
aluminium
curtain wall
frame
tied back to
structure
Void
(possible
insulated)
Closure piece/sill
Structural
column
of building
Sructural floor
Scale (@ A3)
Checked by
Drawn by
Date Project number
www.autodesk.com/revit
STATUS PURPOSE OF ISSUECODE SUITABILITY DESCRIPTION
DRWAING NUMBER REV
PROJECT CLIENT
SHEET
1 : 5
16/05/201408:57:09
CURTAIN WALL SYSTEM
Project Number
276CAB JYOTI PRASHAR
Issue Date
Author
Checker
A102
No. Description Date
9. Rigid Insulation
Grout and reinforced parapet CMU as per
structural requirements
Backer rod
Perimeter of roof insulation wrapped in air control membrane
to block airflow from roof to parapet
roof membrane
2 layers of insulation
Deflection space
Backer rod to fill deflection joint and debond
water and air barrier
fully adhered
water control
membrane
Scale (@ A3)
Checked by
Drawn by
Date Project number
www.autodesk.com/revit
STATUS PURPOSE OF ISSUECODE SUITABILITY DESCRIPTION
DRWAING NUMBER REV
PROJECT CLIENT
SHEET
1 : 5
16/05/201408:57:46
ROOF PARAPET DETAIL
Project Number
276CAB JYOTI PRASHAR
Issue Date
Author
Checker
A103
No. Description Date
Water, air and vapour
control membrane
Peel and stick
transition membrane:
air and water control
Parapet
flashing
10. Scale (@ A3)
Checked by
Drawn by
Date Project number
www.autodesk.com/revit
STATUS PURPOSE OF ISSUECODE SUITABILITY DESCRIPTION
DRWAING NUMBER REV
PROJECT CLIENT
SHEET
1 : 100
16/05/201409:00:48
SECTION CONTINUED
Project Number
276CAB JYOTI PRASHAR
Issue Date
Author
Checker
A107
No. Description Date
1 : 100
SECTION
BOARD ROOMFIRE STAIRS AND ESCAPE TOILETS (MEN AND WOMEN) ELEVATOR STAIRS RECEPTION AREA
FIRE EXIT OTHER SIDE OF ENTRANCE LOADING BAY ENTRANCE TO RECEPTION AREA
11. Scale (@ A3)
Checked by
Drawn by
Date Project number
www.autodesk.com/revit
STATUS PURPOSE OF ISSUECODE SUITABILITY DESCRIPTION
DRWAING NUMBER REV
PROJECT CLIENT
SHEET
16/05/201409:03:02
SECTIONS CONTINUED.
Project Number
276CAB JYOTI PRASHAR
Issue Date
Author
Checker
A114
No. Description Date
SECTION BACK
FIRE EXIT
TOILETS
BOARD ROOM
RECEPTION AREA
ELEVATOR
CAFE
CURVED GLAZED ENTRANCE
CURTAIN
WALLING
STSTEM
RECEPTION AREA