2. Favorite Sport : Tennis
Favorite Food : Free Food
Ultimate non-professional dream: Dunk on a 10 foot basketball goal
More info about me
3. • DFP Area Process Flow Diagram (PFD) Design
• Process Flow Diagram Updates
• Stack testing filing
• Emission Point Drawing Updates
• Reorganizing Environmental Files in Environmental Affairs
• Stack Dimensions Conformation Project
• DFP pH Testing
• Phosphate Analyzer Evaluation
• Total Suspended Solids Analyzer Evaluation
And other tasks
Projects Overview
4. • Pamela Jestness (Air Quality Engineer) uses PFDs in
Air Permit
• Helps understand process
• Shows location of Emission Points in process
DFP Area Process Flow Diagram Design
8. • pH is a permit parameter
• Must be maintained between 6-9
• Believed that higher concentrations of DFP will cause
higher pH in water
• Any kind of acid in the water will lower pH
Defluorinated Feed Phosphate (DFP) pH Testing
9. • Calibrate pH monitor
• Take 500 mL of Tap Water, take initial pH
• Add DFP in 100mg increments
• Mix for 30 sec
• Record pH
• Repeat until 500 mg of DFP is in the water
Experimental setup
Defluorinated Feed Phosphate (DFP) pH Testing
12. • If DFP dissolves in trench water or the oil-water
separator tank the resulting water will have a higher pH
• Lime being dissolved raises pH
• Confirmed other tests results
Results
Defluorinated Feed Phosphate (DFP) pH Testing
13. • Evaluated a phosphate monitor that could be placed into various
streamlines to indicate phosphorous levels
• Permit testing is done from daily composite samples
• Permit limits are 1.5 mg/L daily average and 5 mg/L daily max Total
Phosphorus
• mg/L or part per million (ppm)
Phosphate Analyzer Evaluation
14. • Phosphax and Scantrax
• Phosphax does the test, Scantrax programs and shows results
• Advertised accuracy between .05 ppm – 15 ppm
• Can be programmed to read P2O5, PO4 and PO4-P (elemental P)
• This experiment we were reading PO4 from Phosphax
About the equipment
Phosphate Analyzer Evaluation
15. • Solutions were made to test the advertised range
• Diluted 50 ppm potassium phosphate (KH2PO4) with DI water
• Outfalls 005, 007 and 009 comparisons with equipment in EA Lab
• Lachat monitor is EA lab equipment
• Recoveries of equipment were tested
What was being tested
Phosphate Analyzer Evaluation
19. • TSS is a water quality measurement of any and all solids in water
• Permit Limit is 30 ppm monthly average and 60 ppm daily maximum
• Testing is currently done through Composite samples
• Looking for “early warnings” for Daily max prevention
• Solitax takes readings every 5 minutes and logs the information
• Took composite samples and logged data to compare with monitor and daily
water reports
At 009 outfall
Total Suspended Solids (TSS) Analyzer Evaluation
20. Data collection at 009 outfall.
Total Suspended Solids (TSS) Analyzer Evaluation
24. Comparison Between Solitax and EA lab Testing results
Total Suspended Solids (TSS) Analyzer Evaluation
0.00
5.00
10.00
15.00
20.00
25.00
6/15/2015 6/20/2015 6/25/2015 6/30/2015 7/5/2015 7/10/2015 7/15/2015
TSS(mg/L)
Date
EA Lab and Solitax difference
Solitax
EA Lab
25. • Lab techniques and procedures
• How to form experiments
• How analyzers work
• Water quality
• Stack testing details
• Working with Industrial Salesman
• Evaluations on equipment
What I learned/ new experiences
26. • EA Department
• IT Department
• Tech Services
• Area Supervisors
• HR Department
• Administration
Special Thanks!
27. Shouldn’t the guy who came up with Knock Knock jokes win a “no-bell” Prize?
If you spill a cleaning product, did you make a mess?
Questions?