SlideShare a Scribd company logo
1 of 47
Download to read offline
AD830 DUAL-NET ALARM HOST SYSTEM
User Manual
Preface
Preface
We sincerely gratitude your trust to purchase our “AD830 Alarm Control Panel”series
product, and hope the product can give great convenience and guarantee to your safety.
If you require the latest product performance or function, please
contact your sales directly !
User Manual
“AD 830 Alarm Control Panel” system introduces international most advanced digital
sensor and control technique, is an integrated smart alarm control system combined
anti-burglar, fire, gas leak and other applications, totally compatible with wire and
wireless two alarm methods. Full process with voice prompt, no complicated memory
“AD 830 Alarm Control Panel” system takes advantage of international most advanced
multi-digit random code hopping tech in safety and reliability performance, effectively
solved the problems of interference, false alarm and miss alarm from other systems.
“AD 830 Alarm Control Panel” system uses international common ADEMCO
CONTACT ID method to send alarm signal, expanding its application range and
compatibility. The system can be widely applied in home, community, villa, shops, and
Please read this manual carefully, you can know what the product is and how to use it.
command, easy-operation, easy to learn and use.
public working place, etc.
Content
Content
Accessory List
Chapter 1 Product Overview
1.1 Function
1.2 About Panel
1.3 About Icons
Chapter 2 Installation and Wire Connection
2.1 Open the box
2.2 Install the control panel
2.3 Wire Connection
2.4 Install Wired Detector
2.5 Install Wireless Detector
Chapter 3 GSM Setting&Operation
3.1 Choose GSM Wire and Tel-line Priority
3.2 Check GSM Signal Status
3.3 Exit Setting
3.4 GSM Alarm Receiving& Remote Operation
3.5 GSM SMS Control
3.6 RFID Card SMS Editing
3.7 Alarm Panel GSM Phone Call Function
3.8 Common GSM Suggestions
Chapter 4 Easy Setting&Operation
4.1 Factory Default Setting
4.2 Basic Setting& Operation
4.3 Common Voice Phone Alarm Receiving
4.4 Remote Phone Control
4.5 CMS Alarm Receiving
10
11
11
11
10
1
4 .6 Alarm Procedure
4.7 Tel-line Off Alarm 18
User Manual
4.8 Detector Anti Tamper Alarm
4.9 System Event Record &Query
4.10 Easy Operation
4.14 APP Software
Chapter 5 User Setting
Chapter 6 System Setting
Chapter 7 Technical Specification
7.1 General Data
7.2 Physical Property
Chapter 8 Maintenance&Protection
Chapter 9 Porudct Limitation
6.1 Setting Instruction
5.1 Clock Setting
5.3 User Phone Setting
6.2 Main Menu Setting
5.2 User Password Setting
5.4 Zone Attribution Setting
6.3 Password Setting
6.4 CMS Setting
6.5 User Phone Setting
6.6 System Option Setting
6.7 Enroll Wireless Device
6.8 Zone Attribution Setting
6.9 System Maintenance
6.10 Other Setting
6.11 High-level Settings
Content
24
25
25
24
24
25
24
24
26
28
28
30
34
37
38
40
41
42
42
42
43
43
User Manual
1
.
.
.
.
.
.
..
.
Accessory List
Accessory List
Before installing and setting, please check the Accessory List here, and examine if the
whole set of AD830 alarm control panel including the components as below:
AD 830 Alarm Control Panel
(Include 3M Foam Adhesive )
Telephone line
Power Adaptor
User Manual
10K 1/4 W Resistor
Screw(4*20mm)
Expansive screw( 6mm)
Warranty Card
Certificate of Conformity
1 PC
1 PC
1 PC
1 PC
4 PC
2 PC
2 PC
1 PC
1 PC
User Manual
2
Product Overview
Chapter 1 Product Overview
1. Built-in GSM module, with PSTN and GSM network two alarm methods, send signal
to alarm center by ADEMCO CONTACT ID protocol, arm/disarm with SMS indication,
SMS remote control arm/disarm status, SMS check panel status. PSTN and GSM
network priority optional.
2. Full voice prompt: All local or remote operations, alarm information and event
record query have corresponding voice prompt.
3. User interface: Large LCD screen indicates every steps of operation, working status,
alarm procedure, more convenient and impressive.
1.1 Functions
4. 32 wireless zones: Each zone enables to auto learn code or manually enter address
code on keyboard, the panel compatible of all our made wireless detectors, better to
use these zones.
5. 4 wired zones: Connect resistor on wired zone terminals to achieve NO /NC alarm.
6. Enroll panel series wireless products: The panel can enroll at most 8 remoters, 1
wireless door bell, unlimited one-way wireless sirens.
7. Zone programmable: Every zone of the product has a factory default alarm type.
User can modify them if necessary.
8. Enroll wireless devices: All wireless detectors and remote controllers automatically
enroll code or enter code manually. Each zone can enroll and delete remote controllers
separately, or delete all together.
9. Alarm receiving phone number: It can be set 2 CMS phone number and 4 common
receiving phone number.
10. Clock: Built-in auto calendar/clock, can be set as local time.
11. Event record and query function: Totally record and check 150 different alarm event
messages. Like the time of anti-tamper alarm, detector alarm, arm , disarm, low battery
warning. And also enable to check alarm zone number and alarm type.
12. Password authority: Installer password mainly for administrator to program system,
User Manual
3
Product Overview
user password for common operations as arm, disarm system and remote control, for
improving system’s safety. Both installer and user password can be modified.
13. In central monitoring system, administrator can set 4-digit user number based on
different quantity of user.
14. Alarm type auto identify: After alarm triggered, the LCD screen will display zone
number and alarm type. By networking alarm, panel will report detail zone and alarm
type to CMS.
15. Arm/disarm report to CMS : Optional
16. Remote phone control: Via PSTN dialing and password verified to achieve
remote control system as operations of arm , disarm, monitor indoor status, system
status query.
17. Alarm mode: By standalone phone dialing and GSM, or CMS networking computer
(ADEMCO CONTACT ID), both these two methods auto identify and compatible.
18. Anti-cut alarm: To cut off the wire between wired detector and panel the same as to
trigger an alarm, the tel-line connect to panel cut off that will auto trigger spot high
siren to alarm.
19. Anti-tamper alarm: When someone intends to dismantle the panel deliberately, once
anti-tamper switch triggered , it will alarm immediately.
20. Timing arm/disarm: Enable to set 4 groups timing arm/disarm time, and by the
preset times system arm /disarm automatically.
21. Timing test: According to preset time, send message to CMS to check the panel
online working status.
User Manual
4
Product Overview
22. Voice phone alarm receiving: Alarm can via dialing user’s preset phone number, to
tell user alarm information.
23. Spot siren optional: Built-in siren, and our wireless high siren, both of them can set
on or off according to user’s demand.
24. Voice speaker volume adjustable: Long press 1 to enter volume setting, press to
plus, press to minus.
25. Wire/wireless zone realtime monitor: Enable the option, while arming or disarming,
voice will indicate zone trouble status.
26. Wireless repeat relay function: Our made wireless repeater can achieve panel
receiving signal from detector more stable .
27. Wireless detector low battery warning: When detector battery undervoltage, it will
send status report to panel every 1 to 2 hours, if alarm situation happens, LCD screen
will display corresponding zone number and battery low voltage icon to remind user,
and report to CMS.
28. Press SOS key on the panel or remote to set panel built-in siren whistle or not.
(Refer to 00 zone siren type)
29. During panel remote operating, enter 4-digit user password firstly, in case
unauthorized user to operate it.
30. Networking: PSTN and GSM two networks available, which one priority in use is
up to user.
31. Wireless door bell: Optional( this option takes up one zone)
32. GSM phone call function
33. RFID card SMS programmable
34. Support spot 15s recording function
35. Support portable mobile device APP software control.
User Manual
M D
Y
M D
Y
SOS
RFID
1 ~ 0
LCD Screen
Arm
Disarm
Home Arm
Time
Date
Sending Alarm
Sending to mobile
RFID Card Sense Area
Panic key
Alarm indicator
Fault indicator
One / Volume
Arm/Up key
Disarm/Down key
5
M D
Y
1 2 3
4
7
5
8
0
6
9
SOSRFID
+
-
Numeric Keyboard
Confirm
Zone Setting
LCD Screen
Alarm Indicator
SOS
Play
Fault Indicator
Record
Dial Key
Back
Panel
RFID Card Area
Home Arm/Pause
Event Query/Delete
Product Overview
1.2 About Panel
1.3 About Icons
Away Arm/Up
Disarm/Down
Siren whistle
GSM network signal
Terminal Power
SOS
TEL-line status
Alarm indication
Panel Power
Numeric keys
Home arm/ Pause Key
Event query/Delete key
Back
Confirm
Zone setting
Record
Play
Dial key
User Manual
6
Bracket
Mounting Knockout
Install
Direction
Mounting Hole
Installation& Wire Connection
Chapter 2 Installation & Wire Connection
2.1 Open the box
Open the package to check accessory missing or not (refer to Accessory List), if you
have found accessory missed, please contact local distributor or supplier immediately.
2.2 Install the control panel
An obvious advantage of AD830 alarm setup that it can be installed no need to open.
Cross the wire-way on the back of panel, user can easily connect all wires.
1. Remove the bracket on the back of panel. As picture shows:
Push the bracket along the arrow pointed Remove the bracket
Note: Insert SIM card in
off-power status
2. According to the screw hole on the bracket,
drill holes and fix the bracket on the wall
3. Glue the 3M adhesive on the panel back,
then stick the 3M panel on the wall.
User Manual
Metal
10k
10k
7
10k
10k
12V
GND
BELL+
GND
Z33
Z34
COM
COM
Z35
Z36
NC(Recommend)
Wired siren( ≤350mA)
LINE
TEL Correspondence
external wire
Telephone
POWER:DC15V 2A
Installation& Wire Connection
1. Please don’t put large metal articles around the panel,
in case to influence wireless detector receiving signal.
2. Please install the panel within the invalid distance
that can normally receive signal from detector, and
better putit in a covert place.
As the below picture shows: Hang the panel on the bracket.
2.3 Wire Connection (wired zone support NO or NC detector)
Panel external devices as below:
NO
Output DC12V
Warning: All connectors have power limited!
User Manual
8
Installation& Wire Connection
2.4 Install wired detector
2.4.1 Wired zone has defaulted as bypass status, user can modify it into effective status
if necessary. If wired zone faulted while arming, user will hear “Operation failed,
zone fault”. And the LCD will display the fault zone number+ E, now better not to arm.
2.4.2 The panel can power 12V, 700mA to detectors, don’t exceed 700 mA max current,
or detector need adopt extra DC12V backup power.
2.5 Install wireless detector
2.5.1 As the detector’s manual states, install coded detector in the open area 100~120m
away from the control panel. Please take a walk test, make sure the detector can work
with control panel normally.
2.5.2 Wireless repeat relay function: When wireless detector is too far or blocked by
wall, the panel will disable to receive signal from wireless detector, now you can use
our manufactured wireless repeater relay to achieve wireless signal relay transmitting.
User Manual
9
3.1 Choose GSM and Tel-line Priority
3.2 Check GSM Signal Status
3.3 Exit setting
Press key, to exit setting status
Check gsm signal status, refer to the icon on the top right corner of the screen.
01
02
GSM Priority Setting
Set SMS language
Note: 123789 is installer
password, real operation
please subject to modified
Tel-line Priority
GSM Priority
1
2
GSM Setting&Operation
Chapter 3 GSM Setting&Operation
GSM Menu
Press [ ] >3s+[123789 ]+[8]
Press [ ]>3s+[123789 ]+[8]+[1]+
Setting is saved
Choose 1 as tel-line priority model, GSM standby. Panel alarm prefer tel-line firstly to send
CMS alarm information and dial voice phone no. If tel line cut off or failed, GSM will take
place of it to send CMS report and send message to user!
Choose 2 as GSM priority model, tel-line standby. When this function open, panel will
prefer GSM firstly to report CMS alarm information. And send all information to all preset
voice phone by SMS. Set arm/disarm report to CMS effective if need to remind user arm or
disarm by SMS, operation refers to Page41! If GSM phone under deficit, or signal disturbed,
tel-line will replace it to give CMS report and dialing voice phone.
.
User Manual
10
3.4.1 GSM Alarm Receiving
Panel alarming, GSM sends message firstly, then dial user’s phone number, user
will hear “ system alarm, please receive alarm, cancel alarm press 1, alarm event query
press 2, system away arm press 3, disarm the system press 4, system home arm press 5,
open the siren press 6, monitor the spot press 7, hang up please press 0 ”. Then press 2 to
check, voice indicates “xx zone alarm”, only after confirmed it mistake alarm can user
delete alarm, and press 1 to end alarm. If operate successfully, follow with voice prompt
“operation succeeded”, if not, do it again. Hang up please press 0 ahead. If user no press
1to cancel alarm, and press 0 before hang-up, the panel will dial next voice phone no.
(Repeat 5 times if only one phone number and preset dial time is 5)
3.4.2 GSM Remote Operation
User via phone dial the panel GSM to achieve remote control of system arm/disarm
and status query. Dial GSM card number, enter password after off-hook, default: 8888,
real operation subjects to modified. Follow voice prompt “System away arm press1,
disarm the system press 2, system home arm press 3, system status query press 4, spot
intercom press 9, hang up please press 0”. If operate successfully, user will hear prompt
“operation succeeded”.
3.5 GSM SMS Control
Mobile SMS Arm Command: #pwd8888#Arm
Mobile SMS Disarm Command: #pwd8888#Disarm
Mobile SMS Home Arm Command: #pwd8888#Home
Mobile SMS Status Query Command: #pwd8888#Check
GSM Setting&Operation
3.4 GSM Alarm Receiving& Remote Operation
Details please refer to this manual 4.3 and 4.4 from Page17 to18
Note: User default password is “8888”, password “8888” no space in it,
password is the user modified , when mobile message sent to GSM card
of alarm panel, only enrolled mobile number or message wrote right
password will receive system reply, others won’t.
User Manual
11
GSM Setting&Operation
3.6 RFID Card SMS Editing
By the programmed message text, panel sends out system disarm or home arm
message when swiping card.
For example: Children went back home and swiped the 16th card, system will
disarm and send out a message of “Children back home, system disarm ” to the
user preset mobile number
Operate as:
Use the enrolled phone number to send SMS command to alarm panel GSM card.
The format as : (Remarks: is an English character, within 60 words )“”
Eg.: #pwd8888#MsgRFID01: “Children back home, system disarm ”
(Note: Please set RFID card function before to use, details please refer Page40 )
3.7 Alarm Panel GSM Phone Call Function
Panel can used as phone call under status, operate as: press panel icon, enter
the phone number to dial, press key to confirm, press to hang up after call end.
3.8 Common GSM Suggestions
1.As panel connected to power, open GSM function, if screen appears as
(the icon blinking), indicate that SIM is searching for network , last one minute or so,
these are normal phenomena.
But they if appeared before to use then you must check the power. GSM panel can
work normally only with at least 1.5A power. If power is lower than 1.5 A, GSM restart
or disable to send message to CMS.
2. Please install the panel away from iron, air-conditioner, and big machines.
3.We suggest to test GSM network at least 1 time per week, to make sure GSM working
normally. If not, please check SIM card owe money or not, whether it enrolled success-
fully. Or turn off AC power and close the panel to restart.
User Manual
12
32
01
02
03
04
05
06
07
08~31
Easy Setting &Operation
Chapter4 Easy Setting&Operation
4.1 Factory Default Setting
Below are factory defaults of AD 830 Alarm Control Panel, you can keep the defaults
or modify them.
GSM function: Enabled
Installer password: 123789
User password:8888
Entry and exit delay: 10s
Monitoring time: 10s
Cycle alarm dialing: 5times
Auto off-hook ringing: 7 times
(After ringing 7 times panel will pick phone automatically)
TEL-line off inspection function: Enabled
Auto timing arm/disarm option: Disable
Auto timing arm, disarm and inspection time: 00 (The function disabled)
Alarm types with siren whistle: Delay, indoor(burglar), perimeter, emergency
and 24-hour alarm.
All phone no and user code: Empty
Siren type of panic zone: Mute
Wired zone factory default: Disable
Zone Factory Default
Zone Alarm Type Siren
Table 1:
Perimeter
Delay
Indoor
Indoor
Emergency
24-Hour
Fire
Perimeter
Perimeter
On
On
On
On
Off
On
On
On
On
Zone Default List
Door bell zone: (Optional) Give “ding dong”
sound if triggered, occupys one zone
Indoor(Burglar) zone: Enabled only when
system under away arm status
Perimeter/delay zone: Enabled under arm and
home arm status
Gas, fire, emergency zone: Enabled under both
arm and disarm status
User better not to set zone siren silent
Delay zone: Mainly applied in zones with
entrance or exit.
User Manual
13
M D
Y
M D
Y
LCD Screen
Arm
Disarm
Home Arm
Time
Date
Sending alarm
Sending to mobile
Siren whistle
Network signal
Terminal Power
SOS
Wire status
Alarm indication
Panel Power
Considering the convenience of user, the product preset defaults to meet most users
demand, so common user just do some simple jobs before to use. Please refer to the
follow description, install panel and wireless devices, and connect network to panel.
This chapter illustrates how to use the panel, let you get to know how to operate and
test it before installation.
Zone Fault Indication:
Zone+”E”-----------Zone fault (Wired zone)
Zone+battery icon ---Wireless detector low battery fault
Easy Setting&OperationUser Manual
14
Easy Setting&Operation
4.2 Basic setting & operation
Basic setting:
The panel has already coded with all remote controllers, magnetic contacts, and
pir detectors before left factory, they can auto enter into networking status when
connect to power.
Enter system main menu:
Press key for 3 seconds, then enter installer password 123789
Enter system sub-menu:
Just to press relevant numeric key. Return to previous menu, press key.
System menus all have voice indication, enter main menu the panel will sound all
menus option one time. Press [up], [down] key or corresponding number also have voice
prompt, more friendly and easy to use. After setting press key to save, you will hear
“Setting is saved” , means operate successfully, or failed. On the keyboard from up to
down there are four buttons with normal functions [Away Arm], [Disarm], [Home Arm],
[Event Record Query], while under system setting status, they function as [Up], [Down],
[Pause], [Delete]. The numeric keys on keyboard are for user to enter numbers, key is
back, key is confirm. Under panel standby status, press [SOS] key for 3 seconds is to
seek emergency help.
Indicator:
Alarm indicator-----light blinking
Fault indicator------Indicator light blinking when zone faulted
RFID card indicator-----Indicator light blinking for 3s when swiping card
Basic operation:
Power on/off—When power on AC, system battery auto activated, when AC power off,
enter key for 3s+[4-digit user password]+ press 3s, then panel turns off.
When battery lower to 9.2V, system will turn off automatically to protect the battery.
System setting—long press no less than 3 seconds+ [6-digit installer password]+
System disarm—[4-digit user password]+ , or [4 user password]+[ ]
User Manual
15
1
2
3
4
5
6
7
0
User Operation
System will sound voice indication of setting option when enter into a menu,
press number to enter option setting, system will voice indicates setting details,
press confirm key or press the option 2 times to enter into this option submenu.
4.3 Common Voice Phone Alarm Receiving
When delay zone detector triggered, the panel will sound warning tone, if none
of disarm operation during the period, after pre-alarm panel will make alarm by
dialing the preset voice phone number in turn. After repeat several times and voice
prompts if still no one to receive alarm or do ineffective operation, then panel will
continue to alarm . If phone call get connected, user has made effective operation but
without press 1 to delete alarm and no press 0 before hang-up, the panel will continue
dial other preset phone number.
Voice Phone Alarm Receiving
alarm report
off-hookThe panel will dial preset
voice phone number
Play the recorded voice message first,
then sound:
Cancel alarm press 1
Alarm event query press 2
System away arm press 3
Disarm the system press 4
System home arm press 5
Open the siren press 6
Monitor the spot press 7
Hang up please press 0
4.4 Remote Phone Control
User can remote control the system via phone. Dialing panel connected phone no,
after preset ringing times no answer the panel will off hook the phone, follow voice
prompt, enter correct 4-digit user password, now user can operate the panel by phone.
M D
Y
1 2 3
4
7
5
8
0
6
9
SOSRF
ID
+
-
#
M D
Y
1 2 3
4
7
5
8
0
6
9
SOSRF
ID
+
-
#
M D
Y
1 2 3
4
7
5
8
0
6
9
SOSRF
ID
+
-
#
M D
Y
1 2 3
4
7
5
8
0
6
9
SOSRF
ID
+
-
#
M D
Y
1 2 3
4
7
5
8
0
6
9
SOSRF
ID
+
-
#
M D
Y
1 2 3
4
7
5
8
0
6
9
SOSRF
ID
+
-
#
User Manual
Panel
16
1
2
3
4
X X X X
0
M D
Y
1 2 3
4
7
5
8
0
6
9
SOSRF
ID
+
-
User Operation
MobileMobile Telephone
User call landline phone number The phone will ring 7 times.
After that the panel will
off-hook automatically.
Follow voice prompt ,
enter the user password,
now remote control panel.
Press 3 seconds, enter[8888 ]
Enter the user password
4-digit user password
System away arm press 1
Disarm the system press 2
System home arm press 3
System status query press 4
Hang up please press 0
4.4 CMS Alarm Receiving
The panel use Ademco Contact ID protocol to send alarm information to CMS. If
the panel gets a confirm from the center, then alarm successfully. Or panel will repeat
alarm(redial times preset). The computer software of CMS displays alarm information
and handles the alarm.
4.5 Alarm Procedure
Only the zones set burglary, delay and perimeter alarm types, under away arm, stay
arm and disarm operations, other types zone can alarm normally for whole 24 hours.
* #
User Manual
17
wired
2.A stands for zone alarm, 00 is zone number.
M D
Y
User Operation
Alarm Procedure Diagram:
CMS Telephone Telephone Mobile
3.After CMS, the panel will dial
no1-4 telephones as prest.And
spot siren will sound if preset. If alarm
more than 2 times, then recycle alarm
follow the second and third steps.
wireless
Telecomnetwork
Alarmsoftware
Alarm situation found,
start to send message
1.Detectors activated and
send alarm infromation
to alarm center
alarm center
Receiver 2.The panel sends
alarm information
received to alarm
center computer
wireless
LCD Display: 1. Digital display zone number, wired zone no: 33~36,
wireless zone: 1~30, the 00 zone is panel or remote
W
ireless
M D
Y
1 2 3
4
7
5
8
0
6
9
SOSRF
ID
+
-
#
M D
Y
1 2 3
4
7
5
8
0
6
9
SOSRF
ID
+
-
#
M D
Y
1 2 3
4
7
5
8
0
6
9
SOSRF
ID
+
-
#
M D
Y
1 2 3
4
7
5
8
0
6
9
SOSRF
ID
+
-
#
M D
Y
1 2 3
4
7
5
8
0
6
9
SOSRF
ID
+
-
#
M D
Y
1 2 3
4
7
5
8
0
6
9
SOSRF
ID
+
-
#
User Manual
M D
Y
18
User Operation
4.7 Telephone-line Off Alarm
Under arm status, the siren will whistle immediately once the panel detects the
telephone line cut off. Under disarm status , the panel will give voice about to tell
detected tel-line cut off for about 60 seconds , and during the period, if the tel-line
connected again or disarm the system, indication voice will stop, if not, the siren
begins to whistle. (LCD display as picture below)
4.8 Wireless Detector Anti Tamper Alarm
1. When the panel received a signal from wireless zone detector that anti tamper switch
opened, if under arm status, the panel will solve it as burglar alarm(via status code and
burglar alarm type the detector received). Then only received the signal that the anti-
tamper switch closed can the system continue to solve anti-tamper alarm situations.
2.Anti-tamper switch alarm indication: Screen displays wireless detector zone number,
and burglar icon.
4.9 System Event Record&Query
4.9.1 Event record:
Options: Burglar, away arm, stay arm, disarm, tel-line off, low battery, low battery
restoral setting such information.
Wireless detector (include magnetic contact) low battery monitoring function:
When wireless detector battery is under voltage, the panel shows low battery icon, for
example, zone number is “16”, represents the 16th zone detector battery undervoltage.
Then alarm panel will send this information to alarm center, remind the system
administrator or user to change battery in time, so detector can keep working normally.
If replaced with new battery, detector will send undervoltage restore information to
alarm panel, then panel back to normal work status.
the icon blinking means
tel-line off
User Manual
19
When the AC power off, Fault Indicator blinking, if still no restoration after AC
power off delay setting, then AC loss reported to alarm center, and dial user’s phone,
after AC power restored about 1 minute, alarm center receiver will receive signal of
AC supply again .
User Operation
4.9.2 Event Query
Press [Query] key to check the event recorded. Press the [Query] key continuously
can acquire the previous records in chronological. Press [Up], [Down] keys to navigate,
[Back] key to exit, if no any operations within 20s, the system will exit query status
automatically.
For example: Burglar alarm at the 5th wired zone at 0:12 AM 30th November, 2013
Press “Query”key
Voice Prompt: At 00:12 AM the fifth zone alarm.
Screen will display date, zone no and alarm type.
Press Query key to check next
event record
4.9.3 AC Power Off and Restoral Inspection Function
(Refer to page41 to see details)
User Manual
20
Press disarm key on the remoter,or
enter user passwod +[ ] on the
keyboard, your will hear “dee” and
voice“System Disarmed” means
disarm successfully.
M
M M
MD
D D
D
Y
Y Y
Y
1
1 1
12
2 2
23
3 3
3
4
4 4
4
7
7 7
7
5
5 5
5
8
8 8
8
0
0 0
0
6
6 6
6
9
9 9
9
SOS
SOS SOS
SOSRF
ID
RF
ID
RF
ID
RF
ID
+
+ +
+
-
- -
-
User Operation
4.10 Easy Operation
Away Arm Disarm
Dee Dee Dee Dee
Press key for away arm key
on remoter or keyboard, then
hear “System ,pleasearm exit
the zonearming ”,and “dee, dee”
sound means delay end, system
arm succeeded.
Home Arm SOS
Dee Dee Dee Dee
Press home arm key on remoter or
the keyboard, then hear :“System
home arm”, on the LCD display arm
icon means home arm setting saved.
Press panic key on remoter, or press
“SOS” key 3 seconds, the panel will
send alarm signal and make alarm
according to preset methods.
After the operations above, please browse the “Event Query ” chapter
in this manual if you want to check relevant operation records.
#
# #
#
M
M M
MD
D D
D
Y
Y Y
Y
1
1 1
12
2 2
23
3 3
3
4
4 4
4
7
7 7
7
5
5 5
5
8
8 8
8
0
0 0
0
6
6 6
6
9
9 9
9
SOS
SOS SOS
SOSRF
ID
RF
ID
RF
ID
RF
ID
+
+ +
+
-
- -
-
#
# #
#
M
M M
MD
D D
D
Y
Y Y
Y
1
1 1
12
2 2
23
3 3
3
4
4 4
4
7
7 7
7
5
5 5
5
8
8 8
8
0
0 0
0
6
6 6
6
9
9 9
9
SOS
SOS SOS
SOSRF
ID
RF
ID
RF
ID
RF
ID
+
+ +
+
-
- -
-
#
# #
#
M
M M
D
D D
Y
Y Y
1
1 1
2
2 2
3
3 3
4
4 4
7
7 7
5
5 5
8
8 8
0
0 0
6
6 6
9
9 9
SOS
SOS SOS
RF
ID
RF
ID
RF
ID
+
+ +
-
- -
#
# #
M
M M
D
D D
Y
Y Y
1
1 1
2
2 2
3
3 3
4
4 4
7
7 7
5
5 5
8
8 8
0
0 0
6
6 6
9
9 9
SOS
SOS SOS
RF
ID
RF
ID
RF
ID
+
+ +
-
- -
#
# #
M
M M
D
D D
Y
Y Y
1
1 1
2
2 2
3
3 3
4
4 4
7
7 7
5
5 5
8
8 8
0
0 0
6
6 6
9
9 9
SOS
SOS SOS
RF
ID
RF
ID
RF
ID
+
+ +
-
- -
#
# #
User Manual
4.11 RFID Card SMS Editing(Please refer to page11in this manual)
4.12 Alarm Panel GSM Phone Call Fucntion(Please refer to page11in this manual)
4.13 Mobile APP Function(Please refer to page22~23in this manual)
4.11 GSM SMS Operation (Please refer to page10~11in this manual)
User OperationUser Manual
APP Software
4.14 APP Software
Note: Please download the AD 830 Alarm Control APP software to mobile terminal.
Eg.: 1. Enter panel
SIM card no at the
log-in page phone
no option
2.At the panel
password option
enter any one from
6 group user
password.
Default 4-digit user
password:8888
We suggest user to
modify the
password in time!
3. Click “OK”
button, enter
the function
option
1.The 2nd page of
function setting,
option and interface
as right picture
2 Swipe the screen
left , enter the 3rd
page.
1.The 1st
page of
function
setting,
specific
option
and
interface
as left
picture
shows.
2. Swipe the
screen left,
enter the
2nd page
1. The 3rd
page, specific
option and
interface
please see
picture left.
User Manual
APP Software
Eg.: 1. Enter panel
SIM card no at
log-in page.
2.At host password
option enter any one
from16 group user
password.
Default 4-digit
password:8888
Please modify the
password in time!
3. Click “OK”
button, enter the
function option
1. Remote manual
enroll function,
enroll the remote
ID number in the
panel. So remote
can operate panel.
2.User phone no.
setting function,
hold 4 phone no,
when alarm
situation happens,
the panel will auto
send report to user
phone number.
3.RFID card
manually enroll
the RFID card serial
number in the panel,
so RFID card can
operate the panel.
4.Other functions
under developing!
1.After log-in,
enter the page
as left. Click
the according
function option
(eg.: away arm)
2.Then popup
“away arm”
text indication!
And send an
arming message
to panel.
3. The other
function
settings as
the same.
1. SMS setting
option of
swiping card
can bind the
card no with
specific content
message. While
swiping card,
the panel will
send preset
message to
according
phone no.
2.Entery/exit
delay setting
option, enable
to set entry
and exit delay
time under
arm status.
3. Siren ring
time and volume,
enable to set
ring time
and volume.
4. Master password setting option, enable to modify
the password.
5.Other functions underdeveloping.
User Manual
3 Set User Phone Number
1 Clock Setting
2 Set User Password
Please enter the password number to modify,
press“ ”key to save, press “ ” key to exit.
Please enter new password, press
“ ”key to save, press “ ” key to exit.
1 3
8
8
8
8
8
8
8
8
Factory Default User Password
11 3 0 21 0 0 4 5
01~16
1~4
New User Password
[XXXX] +[#]
[2]+
Set user phone no 1 press 1, set user phone no
[3]+ 2 press 2, set user phone no 3 press3, set use phone
no 4 press 4, set user phone dial time press5. Exit
the setting press key.
+
Note: Exit the setting press[ ]key
Exit the setting press[ ] key
Press[ ]
+[0]+[ ]Note:0 is set off, 1 is set on
+[1]+[ ]
Press to set phone number
User Operation
Chapter 5 User Setting
User Menu
Press[ ] ( > 3 s) [ ]
5.1 Clock Setting
Please enter the system time,
press“ ”key to save, press
“ ” key to exit.
Setting
is saved
According to flash of Y.M.D.H.M on screen, enter 13, 11,30, 00, 12
45 by turn, or by [Up] and [Down] keys to move cursor.
5.2 User Password Setting
+[x]+[xxxxxxxx]+[ # ]
5.4 Zone Attribution Setting(enabled or disable)
5.3 User Phone Setting(Support 4 groups user phone number)
Bypass press 1,
cancel press 0
or
M D
Y
M D
Y
M D
Y
#
# #
Please enter the zone number to
modify, press“ ”key to confirm,
press “ ” key to exit.
Please note: If panel has GSM card, please operate it after 3 minutes power on .
User Manual
Set system on the keyboard, press to save, press to exit setting.
System Setting
Chapter 6 System Setting
This chapter will introduce the function setting of AD 830 series alarm panel,
you can set it according to your demand.
If all settings finished, the panel must restart!
We will not be responsible to the problems caused by user’s incorrect operation!
6.1 Setting Instruction
Every time press a key the panel will sound effective indication speech. Every
time finish an operation wrong or right , the panel will sound corresponding
indication speech. If setting under submenu, press [ ]back to main menu,
to continue other setting.
Under disarm status, press [ ] 3 seconds to enter setting status.“please enter
the password”, enter correct installer password , according to indication, input
relevant option setting command, every time enter correct command please
press[ ] to enter into the submenu, follow the voice, enter the option to be
modified, the screen will display the default or the setting user programmed
before, for user to decide to alter previous setting, now can input the new value,
press [ ] to confirm, or directly press [ ] to save former setting. After this
operation, the screen will back to status o f entering command so that the user
can carry on next option setting. When you finished all settings, press[ ] to exit.
If after 5 minutes no any operation the panel will exit setting automatically.
Only under disarm status, can enter system setting by pressing [ ] for 3s.
If with incorrect operation during setting you can press[ ] back to previous
menu anytime.
6.2 Main Menu Setting
Let’s learn how to enter system and function of each options. All pane setting can
refer to this method, and the panel will keep memory of the setting to work until you
modify it again.
User Manual
8
9
7321
1
2
4
3
5
6
7
1
XX
M M M M
2
Set user password press one
MM M M M M
Setting is saved
Setting is saved
8 9
Password setting
CMS setting
User phone setting
System option setting
Enroll wireless device
Zone setting
System manitenance
Other setting
High-level setting
Please enter the password number to
modify, press“ ”key to confirm,
press “ ” key to exit.
Please enter new password,
press“ ”key to confirm,
press “ ” key to exit.
Set installer password press two
Max.16 groups user password
Under disarm status press key( > 3 s) to enter main menu
System Setting
Main Menu Commands
Please enter the password
6.3 Password Setting
Password consists of “user password”and “ installer password”, “user password”
is user’s private “key” for keyboard disarm or remote control operation, in order
to guarantee your system safety, please set the 4-digit user password convenient to
remember. “installer password” is the only password to set the system, please keep
it in mind if modified, otherwise you can’t operate the system.
Password Setting
Please enter new password, press
“ ”key to save, press “ ” key to exit.
Press [ ] (>3s) +[123789 ]+[1], follow the voice indication to operate.
Please note: If panel has GSM card, please operate it after 3 minutes power on .
User Manual
1 2 3 7 8 9 21
1 2 3 6 5 4
Please enter new password,
press“ ”key to confirm,
press “ ” key to exit.
Example1: Modify the installer password as“123654”
System Setting
Press key (> 3s)
Please enter the password
Setting is saved
Please note:
1. Above are based on correct operation, if incorrect operation occurs, please
press [ ] back to previous menu to reset.
2. The installer passwords introduced to guide here all are the factory preset
default password [123789], password please subject to the modified.
User Manual
#
X X X X
1 2 3 4 5
1
X
2 3 4
X X X X X
5
Set CMS phone
No 1 press 1
Set CMS phone
No 2 press 2
Please enter the phone no,
press delete key to clear,
pause key delay 1s to dial
out, press “ ” to save,
press “ ” to exit.
Please enter the user
number, press“ ”
to save, press “ ”
to exit.
Set CMS user
number press 3
Set CMS
communication
test time press 4
Set CMS dialing
time press 5
CMS network alarm should be authorized by local security service company, common user do not use it!
CMS Setting
System Setting
6.4 CMS Setting
Press [ ] (>3s)+[123789 ]+[ 2 ], then operate as the following voice indication.
Setting is saved Setting is saved
The CMS user number is user’s identification code in the CMS
Please set panel CMS user number after CMS phone number setting.
User code should be 4 digit.
When set CMS phone number, please press “ ” to delete previous data,
if with extension number, press one time to hold on 1second.(for
operator transfer to extension telephone )
Arm disarm report to CMS, this function factory default is disable, if
need CMS network alarm, please refer to page 41.
Please enter the
CMS COMM
test time, enter 0
means no test,
press“ ” to save,
press “ ” to exit.
Please enter the
dialing time press
“ ” to save,
press “ ” to exit.
(hour)
Setting is saved Setting is saved
User Manual
1 2 3 4 5
0 5
1 2 3 37 98
7 6 5 4 3 2 01
1
6.5 User Phone Setting
Set user phone
No1 press 1
Set use phone
No2 press 2
Set use phone
No3 press 3
Set use phone
No4 press 4
Set user phone
dialing time
press 5
Please enter the dialing time
press “ ” to save, press
“ ” to exit.
Setting is saved
Setting is saved
Please enter the phone number,
press delete key to clear, pause key
delay 1s to dial out, press “ ” to
save, press “ ” to exit.
X
X
X
X
XXX
X
XXX
X
X XX X X
Please do not set government public alarm phone no as individual alarm receiving station,
otherwise, users take charge of all negative effects and legal obligation.
Note: Max 17 digits number
System Setting
Press [ ] >3s+[123789 ]+[3], follow the voice indication to operate.
User Phone Setting
Example 2: The panel connect to one phone call, voice alarm receiving phone is local
number: “76543210”, if want to set it as the No1 voice phone:(Pls note: non-local tel
number should add local area code ahead, non-local mobile phone add 0 ahead.)
Press ( >3s)
Please enter password
Please enter the phone no, press
delete key to clear, pause key
delay 1s to dial out, press “ ”
to save, press “ ” to exit.
Setting is saved
User Manual
Clock setting
Entry delay setting
Exit delay setting
Set remote arm/disarm tone
Set siren time
Set phone off-hook ringing time
TEL-line off detection setting
AC loss inspection time setting
Zone faulted arming setting
8
92 81 73
1
2
4
3
5
6
7
1
2
3
4
6
4
9 9
7321 8 9 4 1
1 3 1 1 3 0 0 0 1 2
Please enter the system
time, press to save, press
to exit
6.6 System Option Setting
6.6.1 Clock Setting
For example:set system to 0:12 30th, Nov, 2013
System Setting
Press [ ] >3s+[123789 ]+[4], follow the voice prompt to operate.
Press [ ] > 3s
Operate as: [ ] 3s [ password] [ ] [4] [1] [year]installer
[second][month] [day] [hour] [minute] [ ]
Press [ ] > 3s
According to flash of Y.M.D.H.M on screen, enter 13, 11, 30, 00, 12, 45 by turn,
or by [Up] and [Down] key to set.
Setting is saved
Save setting
Hints: For user to acquire real alarm time, please set the time as local.
M D
Y
M D
Y
M D
Y
#
User Manual
6.6.4 Set Remote Arm /Disarm Tone: the setting of siren indication sound or not
during the period of remote controller arming or disarming (default: no indication )
For example: Set remote arm / disarm tone indication as siren short sound.
6.6.5 Set Siren Time: The siren sounding period after panel start to alarm.
(Default setting is 5 minutes)
For example: set the delay time as 12 minutes(better no more than 12 minutes)
6.6.6 Set Phone Off-hook Ringing Time: The ringing time of panel off-hook when
user phone dial to panel phone number for remote control.
For example: Set off-hook ringing 5 times
4 4
Please enter the siren time from
0 to 30 minutes. Press “ ”
to save, press “ ” to exit.
Please enter the ringing time,
0 means no off-hook. Press
“ ”to save, press “ ” to exit.
1
1
2
0 5
Please select arm/disarm
tone: 1. siren short sound
2. no indication.
Press “ ” to save, press
“ ” to exit.
97321 8
7321 8 9 4 5
7321 8 9 4 6
System Setting
Press [ ] > 3s
Setting is saved
Press [ ] > 3s
Setting is saved
Enter 2-digit number from 0-30, add 0 ahead if lower than 10
Press [ ] > 3s
Setting is saved
Press 2 digit number from 0-15, add 0 ahead if lower than 10
Remark: The ringing time can be set from 0 to 99, the maximum value based
on local condition, when set as 00, means remote phone control disable.
.
User Manual
7321 8 9
9
4
4
2
3
0
0
5
0
7321 8
0
3
Please enter the entry delay
time, press to save,
press key to exit.
Please enter password
Please enter the exit delay
time, press to save,
press key to exit.
System Setting
Press [ ] > 3s
6.6.2 Entry Delay Setting: Panel delay alarming period after alarm triggered.
(Default value is 10s)
E.g: Set the delay time as 5s
Setting is saved
Please enter 3 digit number from 001 - 225.
6.6.3 Exit Delay Setting: The period from user arm system on keyboard or remoter,
to system successfully armed and exit setting.( Default value is 10s)
For example: Set delay time as 30 s
Press [ ] > 3s
Setting is saved
Please enter 3 digit number from 001 - 225.
Note: Entry delay enabled only in entry/exit zone. Exit delay enabled
only in perimeter, burglar, delay zone.
User Manual
1
0
1
5 0
6.6.7 TEL-line Off Detection Setting: Detect the telephone line whether connect
normally, it will alarm if not. ( Default: )detect tel-line
For example: Set tel-line with detection.
6.6.8 AC Loss Inspection Time Setting: The panel will send the inspection time to
CMS and user after AC loss.
6.6.9 Zone Faulted Arming Setting: Set arm function effective or not under zone
trouble status.(factory default: disable)
For example: Set zone faulted arm function enabled.
7
7
7
3
3
3
2
2
2
1
1
1
8
8
8
9
9
9
4
4
4
7
8
9
Please choose: 1. detect
tel-line 2. not detect
Press to save, press to exit.
Please choose:
1. Enabled
2. Disable
.Press to save, press to exit
Please enter the AC loss inspection
time from 0 to 255 minutes, zero
means no inspection.
.Press to save, press to exit
Press [ ] > 3s
Setting is saved
Press [ ] > 3s
Setting is saved
Press [ ] > 3s
Setting is saved
System SettingUser Manual
7
7
3
3
2
2
1
1
5
5 1 2
8
8
9
9
1.Remote controller code study
1.Detector code study
1.wireless siren code study
1.RFID card code study
2.Enter remote controller code
2.Enter Detector code
2.wireless siren code delete
2.RFID card code delete
3.Remote controller code delete
3.Detector code delete
Enroll Remote controller
Enroll Detector
Enroll Wireless siren
Enroll RFID card
Please enter the remote
number. Press “ ” key
to confirm, press “ ”
key to exit.
Please enter the remote no.
Press “ ” to confirm, press
“ ” to exit.
Please enter the remote
code. Press “ ” to
confirm, press “ ” to exit.
3
7
(1)Auto Enrolling:
(2)Enroll Manually
3 0322 2 01 5
Please trigger the
remote to enroll,
press key to exit
Setting
is saved
7321 5 1 58 9
Trigger Remote
Arming key
Press “ ” key
to save, press “ ”
key to exit.
For example: enroll the third remote in the panel automatically.
For example: Set the 7th remote address code:223321005, manually input into the panel.
9-digit address code
6.7 Enroll Wireless Device
1.
2.
3.
4.
System Setting
Press [ ] > 3s
Please follow the voice
prompt to operate
We suggest user to enroll all devices by manually entering codes.
6.7.1 Remote Controller Enrolling and Delete
Press [ ] > 3s
Press [ ] > 3s
Setting is saved
User Manual
1
1
2
5
(1)Auto enrolling
(2) Manually enrolling
(3).Delete Remote Code
6.7.2 Detector Enrolling and Delete
1 8
7
7
7
3
3
3
2
2
2
1
1
1
8
8
8
9
9
9
5
5
5
1
2
2
3
1
2
Please enter the remote
number to delete, enter
zero to delete all remoter.
Press “ ” to confirm,
press “ ” to exit.
Please enter the detector no.
Press “ ” key to confirm,
press “ ” key to exit.
Please enter the detector no.
Press “ ” key to confirm,
press “ ” key to exit.
Please enter the detector no.
to delete, enter 00 to delete
all detectors.. Press “ ” to
save, press “ ” to exit.
Please enter the detector code.
Press “ ” key to save,
press “ ” key to exit.
Please trigger the detector
to enroll, press key to exit
6
7321 8 9 5 2 3
E.g: Delete the 6th remote controller
Example: manually input the address code:223321006 into the panel 15th zone
3 0322 2 01 6
9-digit address code
System Setting
Press [ ] > 3s
Setting is saved
Setting is saved
Example: Delete the 18th detector
Example:Enroll the wireless detector in 12th zone
Press [ ] > 3s
Setting is saved
Press [ ] > 3s
Press [ ] > 3s
Setting is saved
Press “ ” to save,
press “ ” to exit.
35
User Manual
6.7.3 Enroll Wireless Siren
3
3
3
2
2
2
1
1
1
2
2
0
0
0
4
4
4
5
5
5
5
5
5
3
4
4
1
1
1
0
0
0
Please set the siren to enroll,
press to begin. Return to the
previous menu press key.
Please enter the RFID card
number to enroll, press to
confirm, press key to exit.
Please enter the RFID card
number to delete, press to
confirm, press key to exit.
Siren begin to enroll, please
enter the next step after voice
prompt. Return to the previous
menu press key.
Please put the RFID card
on Induction Area
Please confirm the RFID card number to delete.
Press “ ” key to save, press “ ” key to exit.
Setting is
saved
Setting is
saved
Setting is
saved
trigger the
siren to enroll
Press “ ” key to
save, press “ ”
key to exit.
Press “ ” key to
save, press “ ”
key to exit.
System Setting
For example:
Press [ ] > 3s
Press [ ] > 3s
Press [ ] > 3s
Press the wireless siren SAVE key and hold on until the siren whistle that the siren
successfully enrolled, press[ ] to exit. Or refer to relevant siren operation guide.
6.7.5 RFID Card Study Function
1. Enroll RFID Card#02
6.7.4 Delete Wireless Siren: Please refer to voice prompt.
2. Enroll RFID Card#02
.
User Manual
1 2 3 4
X XX X
0 1 2 3 4 5 6
Please select zone type: 0. Disable
1. delay zone 2.perimeter
zone 3. Indoor (burglar) zone 4.SOS
zone. 5. 24-hour zone. 6. fire zone.
.Press to save, press to exit
Please select
siren type:
1.pedal point
2.pulse tone
3.mute
Please select siren
type:1.pedal point
2.pulse tone 3.mute
Press to save,
press to exit.
IndoorZone
FireZone
24-hourzone
Note: 00 is only used
as the SOS key on the
panel or remote
System Setting
6.8 Zone Attribution Setting
Press [ ] >3s+[123789 ]+[6], follow the voice prompt to operate.
Zone Attribution Setting
Set sos siren
type press 3
Set zone door
contact open
detection press4
Please choose:
1.Detect
2. Not detect
Press to save,
press to exit.
Setting is saved
Setting is savedSetting is saved
SOSZone
PerimeterZone
DelayZone
Disable
Setting is saved
Indoor(Burglar) Zone: Enabled only at system away arming status.
Delay, Perimeter Zone: Enabled only at system away arming or stay arming status.
Set zone attribution
press 1
Please enter the zone no.
to modify. Press to
confirm, press to exit.
Set zone siren
type press 2
Please enter the zone no
to modify. Press to
confirm, press to exit.
User Manual
42 31 5
Set timing arm/
disarm press 1
Record alarming voice
message press 2
Play alarming voice
message press 3
Delete system
log press 4
Restore factory
setting press 5
Please enter timing arm
disarm group number.
Press to confirm, press
to exit.
Please confirm
again! Press
to save, press
to exit.
Please confirm again!
Press to save,
press to exit.
Please start to
record after
ringing
Note: record time is15 s
Please enter timing arm
time, 0:0 is invalid. Press
to save, press to exit.
Please enter timing
disarm time, 0:0 is invalid.
.Press to save, press to exit
Setting is saved
Setting is saved Setting is saved
Press [ ] >3s+[123789 ]+[7], follow the voice prompt to operate.
System Setting
7.0 System Maintenance
System Maintenance
Note: Any operation before the end of this
voice prompt is ineffective!
User Manual
9 7 1321 7 8
System Setting
Example: Set timing arm at 20:30PM, timing disarm at 07:05AM
Press [ ] > 3s Please enter timing arm
disarm group number.
Press to confirm, press
to exit.
Please enter timing arm
time, 0:0 is invalid. Press
to save, press to exit.
Please enter timing disarm
time, 0:0 is invalid. Press
to save, press to exit.
Setting is saved
Hint: 4 groups of timing arm/disarm can be set according to
the schedule of user
User Manual
1 2 3
SMS language
setting press 2
RFID card option
setting press 3
GSM priority
setting press 1
Setting is saved! Setting is saved!
Setting is saved!
Please choose:
1.Tel-line priority
2.GSM priority
Please choose:
1.Chinese
2.English
Please enter the RFID card no,
.Press to confirm, press to exit
Other Setting
1
X X
2 3 4 5 6
SystemDisarm
SystemDisarm&
SendMessage
SystemArm
SystemHomeArm
&SendMessage
SystemDisarm
&DialPhoneNo1
SystemHomeArm
&DialUserPhone
No1
For example: After your children back to home, swip the No 03 RFID, system will
disarm and send message to user phone No1, operate as below:
89 3 0 3 2321 7 8
X X
Other Setting
Press [ ] >3s+[123789 ]+[8], follow the voice prompt to operate.
8.0 Other Setting
Press [ ] >3s
Meanwhile, the user should send message to panel
(details please refer to Page 11,section 3 and 8)
User Manual
39
High-level Setting
Alarm Information Delivery Methods:
0. No delivery
1. Only send message to CMS
2. Only dial user phone no
3. Dial user phone no+ Send Message
4. Only report to CMS
5. Report to CMS+ Send Message
6. Report to CMS + Dial user phone no
7. Report to CMS + Dial user phone no+Send Message
Example1: After (AC Loss), dial user phone no and send message and report to CMS.
Example2: After (System Disarm), report to CMS.
Example3: After (System Home Arm), report to CMS.
Example4: After (System Away Arm), report to CMS.
7
7
7
7
3
3
3
3
2
2
2
2
1
1
1
1
8
8
8
8
9
9
9
9
9
9
9
9
13
24
25
26
7
4
4
4
COMM Test
TEL-line Off 5(Default)
5(Default)
0(Default)
0(Default)
0(Default)
0(Default)
0(Default)
0(Default)
0(Default)
0(Default)
0(Default)
5(Default)
4(Default)
4(Default)
17
16
18
19
20
21
22
23
25
26
27
28
29
30
Wired Zone Fault
Wired Zone Restoral
Battery Restoral Event
COMM Failure
Zone Bypass Restoral
Alarm Cancel
System Home Arm
System Away Arm
System Programing
System Arm Failure
Tel-line Restoral
COMM Restoral
0(Default)24 System Disarm
Alarm Type Alarm TypeDelivery Code Delivery CodeNo No
Delay Zone
SOS 7(Default)
7(Default)
7(Default)
7(Default)
7(Default)
7(Default)
7(Default)
7(Default)
5(Default)
5(Default)
5(Default)
5(Default)
5(Default)
5(Default)
5(Default)
02
01
03
04
05
06
07
08
09
10
11
12
13
14
15
Perimeter Zone
Burglar Zone
24H Zone
SOS Zone
Fire Zone
Tamper Zone
Battery Failure
Battery Restoral Zone
Detector Loss Event
Battery Failure Event
AC Loss
AC Restoral Event
Bypass Event
9.0 High-level Setting: (alarm information delivery)
Press [ ] >3s
Press [ ] >3s
Press [ ] >3s
Press [ ] >3s+[123789 ]+[9], according to the following code to opearte.
Press [ ] >3s
User Manual
Technical Specification
Chapter 7 Technical Specification
7.1 General Data
1. Area data: 4 wired areas, 32 wireless zones, 8 remote controllers
2. Zone type: Delay, perimeter, burglar, emergency, fire, gas, key, door bell,
permanent bypass.
3.Frequency: 433MHz
4. Signal transmit distance: Open area (100~120 m)
5. Power supply: 15V/2000mA
6.Built-in rechargeable battery: 11.1V/800 mA
7. Panel static current: <80 mA(12V, exclude wire detector current)
8. Panel alarm current: <350 mA/12V(exclude high siren current)
9. Panel 12V max output current: ≤ 350mA ( for wire detector)
10. Recording time: 15s
11. RF frequency: 433 Mhz 0.5MHz
12. Wired zone triggered delay: ≥700ms
13. Alarm dial method: PSTN and GSM
14. DTMF dial frequency tolerance: <1.5%
15. CMS Communication protocol: Ademco Contact ID
7.2 Physical Property
1. Operation temperature range: 0 ℃~ 45℃ (32℉ ~ 120℉)
2. Storage temperature range: -20℃~ 60℃ (-4℉~140℉)
3. Humidity: 85% RH, at temperature of 30℃(86℉)
4. Size: 200*145*32mm(L*W*H)
5. Weight: 410g(standalone, exclude the battery)
6. Color: White
User Manual
42
Maintenance
Chapter 8 Maintenance
8.1 Regular test
The alarm system design on principle of saving customers’ maintenance cost, but we
still suggest you to carry out “periodical test” one time every month, to guarantee the
system’s working reliability. And please contact the installer
immediately if you have found something wrong.
8.2 Cleaning of the control panel machine
After a period of using, the control panel may be oil-stained or dust-covered. Please
use soft cotton cloth or sponge to clean it.
Note: Don’t use any lubricant or organic solvent, such as kerosene, acetone and super
glue to clean the machine shell, in case to influence the external appearance and the
top window transparency.
Chapter 9 Product Limitation
Although the products you bought is high standard, but there still has problems as
false alarm or miss alarm, the reasons may be as below:
Lack of Maintenance: The system needs maintenance and test regularly, the detector
sensitivity decreasing , may result in false or miss alarm, and the siren disable to
to whistle.
Lack of Power Supply: If no power restore or backup power is not enough, the panel
can not work normally, it can’t alarm even zone has alarm situation.
Tel-line Trouble: If the telephone line is cut or short-circuit, the panel could not send
out alarm signals.
Limitation of Smoke Detector: Sometimes, because of house design or distance too
far for the smoke detector to receive alarm signal that may cause miss alarm.
System disable to receiving information: If the intruder break in through unprotected
window or unknown entrance, or some one knows how to make the alarm devices
disable to alarm.
In order to guarantee detector and the whole alarm system to work normally, we
suggest user to test it frequently. Even installed our alarm system, user still should
keep caution of life and property safety. We will keep on developing new security&
protection series product, please pay attention to our product update status, to get our
latest technical product and relevant material. Your support is our motivation!
User Manual

More Related Content

What's hot

VLSI process integration
VLSI process integrationVLSI process integration
VLSI process integrationneha sharma
 
6.1. thermal oxidation 1,2.micro tech,2013
6.1. thermal oxidation 1,2.micro tech,20136.1. thermal oxidation 1,2.micro tech,2013
6.1. thermal oxidation 1,2.micro tech,2013Bhargav Veepuri
 
2012 Introduction wire bonding
2012 Introduction wire bonding2012 Introduction wire bonding
2012 Introduction wire bondingJan Eite Bullema
 
White paper on ESD protection for 40nm/28nm
White paper on ESD protection for 40nm/28nmWhite paper on ESD protection for 40nm/28nm
White paper on ESD protection for 40nm/28nmbart_keppens
 
Optimizing I/O’s and ESD protection to reduce power consumption in SOI applic...
Optimizing I/O’s and ESD protection to reduce power consumption in SOI applic...Optimizing I/O’s and ESD protection to reduce power consumption in SOI applic...
Optimizing I/O’s and ESD protection to reduce power consumption in SOI applic...Sofics
 
Pcb manufacturing
Pcb manufacturingPcb manufacturing
Pcb manufacturingClement Ang
 
Ultra Thin Body SOI FETs
Ultra Thin Body SOI FETsUltra Thin Body SOI FETs
Ultra Thin Body SOI FETssindhu reddy
 
Chapter 10 Etching _ I.pptx
Chapter 10 Etching _ I.pptxChapter 10 Etching _ I.pptx
Chapter 10 Etching _ I.pptxsamadali39
 

What's hot (20)

VLSI process integration
VLSI process integrationVLSI process integration
VLSI process integration
 
Fabrication process flow
Fabrication process flowFabrication process flow
Fabrication process flow
 
Etching Process
Etching ProcessEtching Process
Etching Process
 
PCB
PCBPCB
PCB
 
6.1. thermal oxidation 1,2.micro tech,2013
6.1. thermal oxidation 1,2.micro tech,20136.1. thermal oxidation 1,2.micro tech,2013
6.1. thermal oxidation 1,2.micro tech,2013
 
2012 Introduction wire bonding
2012 Introduction wire bonding2012 Introduction wire bonding
2012 Introduction wire bonding
 
PCB MANUFACTURING
PCB MANUFACTURINGPCB MANUFACTURING
PCB MANUFACTURING
 
White paper on ESD protection for 40nm/28nm
White paper on ESD protection for 40nm/28nmWhite paper on ESD protection for 40nm/28nm
White paper on ESD protection for 40nm/28nm
 
Pcb 101
Pcb 101Pcb 101
Pcb 101
 
Optimizing I/O’s and ESD protection to reduce power consumption in SOI applic...
Optimizing I/O’s and ESD protection to reduce power consumption in SOI applic...Optimizing I/O’s and ESD protection to reduce power consumption in SOI applic...
Optimizing I/O’s and ESD protection to reduce power consumption in SOI applic...
 
Pcb manufacturing
Pcb manufacturingPcb manufacturing
Pcb manufacturing
 
PCB
PCB PCB
PCB
 
PCB 101 - How To Build a Circuit Board
PCB 101 - How To Build a Circuit BoardPCB 101 - How To Build a Circuit Board
PCB 101 - How To Build a Circuit Board
 
Ultra Thin Body SOI FETs
Ultra Thin Body SOI FETsUltra Thin Body SOI FETs
Ultra Thin Body SOI FETs
 
Pcb design
Pcb designPcb design
Pcb design
 
Oxidation
OxidationOxidation
Oxidation
 
Oxidation--ABU SYED KUET
Oxidation--ABU SYED KUETOxidation--ABU SYED KUET
Oxidation--ABU SYED KUET
 
Chrzest
ChrzestChrzest
Chrzest
 
Chapter 10 Etching _ I.pptx
Chapter 10 Etching _ I.pptxChapter 10 Etching _ I.pptx
Chapter 10 Etching _ I.pptx
 
GebrüDer Grimm
GebrüDer GrimmGebrüDer Grimm
GebrüDer Grimm
 

Similar to Ad830 user manual

IOS/Android Touch lcd gsm alarm system LS-GSM-215
IOS/Android Touch lcd gsm alarm system LS-GSM-215IOS/Android Touch lcd gsm alarm system LS-GSM-215
IOS/Android Touch lcd gsm alarm system LS-GSM-215Alice Hsu
 
GSM Commercial Alarm Systems
GSM Commercial Alarm SystemsGSM Commercial Alarm Systems
GSM Commercial Alarm Systemsburglaralarm
 
INTELLIGENT ACCESS CONTROL. TIME &amp; ATTENDANCE SYSTEM
INTELLIGENT ACCESS CONTROL. TIME &amp; ATTENDANCE SYSTEMINTELLIGENT ACCESS CONTROL. TIME &amp; ATTENDANCE SYSTEM
INTELLIGENT ACCESS CONTROL. TIME &amp; ATTENDANCE SYSTEMwisdom0313
 
SenseTek Stratos Micra 25 installers handbook
SenseTek Stratos Micra 25 installers handbookSenseTek Stratos Micra 25 installers handbook
SenseTek Stratos Micra 25 installers handbookHans Bronkhorst
 
s130-s150-user-manual-v1-50.pdf
s130-s150-user-manual-v1-50.pdfs130-s150-user-manual-v1-50.pdf
s130-s150-user-manual-v1-50.pdfIbidhiEskander
 
Smart DoorLock System using DTMF
Smart DoorLock System using DTMFSmart DoorLock System using DTMF
Smart DoorLock System using DTMFBirinchi Medhi
 
Smart Door Lock System Using DTMF
Smart Door Lock System Using DTMFSmart Door Lock System Using DTMF
Smart Door Lock System Using DTMFBirinchi Medhi
 
Digital Watchdog DW-VC161T User Manual
Digital Watchdog DW-VC161T User ManualDigital Watchdog DW-VC161T User Manual
Digital Watchdog DW-VC161T User ManualJMAC Supply
 
Security service equipment integrated CCTV and burglar fire alarm
Security service equipment integrated CCTV and burglar fire alarmSecurity service equipment integrated CCTV and burglar fire alarm
Security service equipment integrated CCTV and burglar fire alarmVedard Security Alarm System Store
 
IJERD (www.ijerd.com) International Journal of Engineering Research and Devel...
IJERD (www.ijerd.com) International Journal of Engineering Research and Devel...IJERD (www.ijerd.com) International Journal of Engineering Research and Devel...
IJERD (www.ijerd.com) International Journal of Engineering Research and Devel...IJERD Editor
 
Vutlant Products for Server room Monitoring.pptx
Vutlant Products for Server room Monitoring.pptxVutlant Products for Server room Monitoring.pptx
Vutlant Products for Server room Monitoring.pptxdicttrainganddevelop
 
Security Solution By Digital Enterprises, Sahibabad
Security Solution By Digital Enterprises, SahibabadSecurity Solution By Digital Enterprises, Sahibabad
Security Solution By Digital Enterprises, SahibabadIndiaMART InterMESH Limited
 
DTMF based Home Automation System
DTMF based Home Automation SystemDTMF based Home Automation System
DTMF based Home Automation SystemDaksh Raj Chopra
 
Q8 Face Recognition & Face Temperature Integrated Detector - Contact-less Tem...
Q8 Face Recognition & Face Temperature Integrated Detector - Contact-less Tem...Q8 Face Recognition & Face Temperature Integrated Detector - Contact-less Tem...
Q8 Face Recognition & Face Temperature Integrated Detector - Contact-less Tem...AshwiniS72
 
Honeywell gsmx-install-guide
Honeywell gsmx-install-guideHoneywell gsmx-install-guide
Honeywell gsmx-install-guideAlarm Grid
 

Similar to Ad830 user manual (20)

IOS/Android Touch lcd gsm alarm system LS-GSM-215
IOS/Android Touch lcd gsm alarm system LS-GSM-215IOS/Android Touch lcd gsm alarm system LS-GSM-215
IOS/Android Touch lcd gsm alarm system LS-GSM-215
 
Manuale wg yl007m2h-look_ing_2.0
Manuale wg yl007m2h-look_ing_2.0Manuale wg yl007m2h-look_ing_2.0
Manuale wg yl007m2h-look_ing_2.0
 
F0463842
F0463842F0463842
F0463842
 
GSM Commercial Alarm Systems
GSM Commercial Alarm SystemsGSM Commercial Alarm Systems
GSM Commercial Alarm Systems
 
GSM Based Security System
GSM Based Security SystemGSM Based Security System
GSM Based Security System
 
INTELLIGENT ACCESS CONTROL. TIME &amp; ATTENDANCE SYSTEM
INTELLIGENT ACCESS CONTROL. TIME &amp; ATTENDANCE SYSTEMINTELLIGENT ACCESS CONTROL. TIME &amp; ATTENDANCE SYSTEM
INTELLIGENT ACCESS CONTROL. TIME &amp; ATTENDANCE SYSTEM
 
SenseTek Stratos Micra 25 installers handbook
SenseTek Stratos Micra 25 installers handbookSenseTek Stratos Micra 25 installers handbook
SenseTek Stratos Micra 25 installers handbook
 
s130-s150-user-manual-v1-50.pdf
s130-s150-user-manual-v1-50.pdfs130-s150-user-manual-v1-50.pdf
s130-s150-user-manual-v1-50.pdf
 
Smart DoorLock System using DTMF
Smart DoorLock System using DTMFSmart DoorLock System using DTMF
Smart DoorLock System using DTMF
 
Smart Door Lock System Using DTMF
Smart Door Lock System Using DTMFSmart Door Lock System Using DTMF
Smart Door Lock System Using DTMF
 
Digital Watchdog DW-VC161T User Manual
Digital Watchdog DW-VC161T User ManualDigital Watchdog DW-VC161T User Manual
Digital Watchdog DW-VC161T User Manual
 
Security service equipment integrated CCTV and burglar fire alarm
Security service equipment integrated CCTV and burglar fire alarmSecurity service equipment integrated CCTV and burglar fire alarm
Security service equipment integrated CCTV and burglar fire alarm
 
IJERD (www.ijerd.com) International Journal of Engineering Research and Devel...
IJERD (www.ijerd.com) International Journal of Engineering Research and Devel...IJERD (www.ijerd.com) International Journal of Engineering Research and Devel...
IJERD (www.ijerd.com) International Journal of Engineering Research and Devel...
 
Vutlant Products for Server room Monitoring.pptx
Vutlant Products for Server room Monitoring.pptxVutlant Products for Server room Monitoring.pptx
Vutlant Products for Server room Monitoring.pptx
 
J04701080085
J04701080085J04701080085
J04701080085
 
Security Solution By Digital Enterprises, Sahibabad
Security Solution By Digital Enterprises, SahibabadSecurity Solution By Digital Enterprises, Sahibabad
Security Solution By Digital Enterprises, Sahibabad
 
Spec00310
Spec00310Spec00310
Spec00310
 
DTMF based Home Automation System
DTMF based Home Automation SystemDTMF based Home Automation System
DTMF based Home Automation System
 
Q8 Face Recognition & Face Temperature Integrated Detector - Contact-less Tem...
Q8 Face Recognition & Face Temperature Integrated Detector - Contact-less Tem...Q8 Face Recognition & Face Temperature Integrated Detector - Contact-less Tem...
Q8 Face Recognition & Face Temperature Integrated Detector - Contact-less Tem...
 
Honeywell gsmx-install-guide
Honeywell gsmx-install-guideHoneywell gsmx-install-guide
Honeywell gsmx-install-guide
 

Ad830 user manual

  • 1. AD830 DUAL-NET ALARM HOST SYSTEM User Manual
  • 2. Preface Preface We sincerely gratitude your trust to purchase our “AD830 Alarm Control Panel”series product, and hope the product can give great convenience and guarantee to your safety. If you require the latest product performance or function, please contact your sales directly ! User Manual “AD 830 Alarm Control Panel” system introduces international most advanced digital sensor and control technique, is an integrated smart alarm control system combined anti-burglar, fire, gas leak and other applications, totally compatible with wire and wireless two alarm methods. Full process with voice prompt, no complicated memory “AD 830 Alarm Control Panel” system takes advantage of international most advanced multi-digit random code hopping tech in safety and reliability performance, effectively solved the problems of interference, false alarm and miss alarm from other systems. “AD 830 Alarm Control Panel” system uses international common ADEMCO CONTACT ID method to send alarm signal, expanding its application range and compatibility. The system can be widely applied in home, community, villa, shops, and Please read this manual carefully, you can know what the product is and how to use it. command, easy-operation, easy to learn and use. public working place, etc.
  • 3. Content Content Accessory List Chapter 1 Product Overview 1.1 Function 1.2 About Panel 1.3 About Icons Chapter 2 Installation and Wire Connection 2.1 Open the box 2.2 Install the control panel 2.3 Wire Connection 2.4 Install Wired Detector 2.5 Install Wireless Detector Chapter 3 GSM Setting&Operation 3.1 Choose GSM Wire and Tel-line Priority 3.2 Check GSM Signal Status 3.3 Exit Setting 3.4 GSM Alarm Receiving& Remote Operation 3.5 GSM SMS Control 3.6 RFID Card SMS Editing 3.7 Alarm Panel GSM Phone Call Function 3.8 Common GSM Suggestions Chapter 4 Easy Setting&Operation 4.1 Factory Default Setting 4.2 Basic Setting& Operation 4.3 Common Voice Phone Alarm Receiving 4.4 Remote Phone Control 4.5 CMS Alarm Receiving 10 11 11 11 10 1 4 .6 Alarm Procedure 4.7 Tel-line Off Alarm 18 User Manual
  • 4. 4.8 Detector Anti Tamper Alarm 4.9 System Event Record &Query 4.10 Easy Operation 4.14 APP Software Chapter 5 User Setting Chapter 6 System Setting Chapter 7 Technical Specification 7.1 General Data 7.2 Physical Property Chapter 8 Maintenance&Protection Chapter 9 Porudct Limitation 6.1 Setting Instruction 5.1 Clock Setting 5.3 User Phone Setting 6.2 Main Menu Setting 5.2 User Password Setting 5.4 Zone Attribution Setting 6.3 Password Setting 6.4 CMS Setting 6.5 User Phone Setting 6.6 System Option Setting 6.7 Enroll Wireless Device 6.8 Zone Attribution Setting 6.9 System Maintenance 6.10 Other Setting 6.11 High-level Settings Content 24 25 25 24 24 25 24 24 26 28 28 30 34 37 38 40 41 42 42 42 43 43 User Manual
  • 5. 1 . . . . . . .. . Accessory List Accessory List Before installing and setting, please check the Accessory List here, and examine if the whole set of AD830 alarm control panel including the components as below: AD 830 Alarm Control Panel (Include 3M Foam Adhesive ) Telephone line Power Adaptor User Manual 10K 1/4 W Resistor Screw(4*20mm) Expansive screw( 6mm) Warranty Card Certificate of Conformity 1 PC 1 PC 1 PC 1 PC 4 PC 2 PC 2 PC 1 PC 1 PC User Manual
  • 6. 2 Product Overview Chapter 1 Product Overview 1. Built-in GSM module, with PSTN and GSM network two alarm methods, send signal to alarm center by ADEMCO CONTACT ID protocol, arm/disarm with SMS indication, SMS remote control arm/disarm status, SMS check panel status. PSTN and GSM network priority optional. 2. Full voice prompt: All local or remote operations, alarm information and event record query have corresponding voice prompt. 3. User interface: Large LCD screen indicates every steps of operation, working status, alarm procedure, more convenient and impressive. 1.1 Functions 4. 32 wireless zones: Each zone enables to auto learn code or manually enter address code on keyboard, the panel compatible of all our made wireless detectors, better to use these zones. 5. 4 wired zones: Connect resistor on wired zone terminals to achieve NO /NC alarm. 6. Enroll panel series wireless products: The panel can enroll at most 8 remoters, 1 wireless door bell, unlimited one-way wireless sirens. 7. Zone programmable: Every zone of the product has a factory default alarm type. User can modify them if necessary. 8. Enroll wireless devices: All wireless detectors and remote controllers automatically enroll code or enter code manually. Each zone can enroll and delete remote controllers separately, or delete all together. 9. Alarm receiving phone number: It can be set 2 CMS phone number and 4 common receiving phone number. 10. Clock: Built-in auto calendar/clock, can be set as local time. 11. Event record and query function: Totally record and check 150 different alarm event messages. Like the time of anti-tamper alarm, detector alarm, arm , disarm, low battery warning. And also enable to check alarm zone number and alarm type. 12. Password authority: Installer password mainly for administrator to program system, User Manual
  • 7. 3 Product Overview user password for common operations as arm, disarm system and remote control, for improving system’s safety. Both installer and user password can be modified. 13. In central monitoring system, administrator can set 4-digit user number based on different quantity of user. 14. Alarm type auto identify: After alarm triggered, the LCD screen will display zone number and alarm type. By networking alarm, panel will report detail zone and alarm type to CMS. 15. Arm/disarm report to CMS : Optional 16. Remote phone control: Via PSTN dialing and password verified to achieve remote control system as operations of arm , disarm, monitor indoor status, system status query. 17. Alarm mode: By standalone phone dialing and GSM, or CMS networking computer (ADEMCO CONTACT ID), both these two methods auto identify and compatible. 18. Anti-cut alarm: To cut off the wire between wired detector and panel the same as to trigger an alarm, the tel-line connect to panel cut off that will auto trigger spot high siren to alarm. 19. Anti-tamper alarm: When someone intends to dismantle the panel deliberately, once anti-tamper switch triggered , it will alarm immediately. 20. Timing arm/disarm: Enable to set 4 groups timing arm/disarm time, and by the preset times system arm /disarm automatically. 21. Timing test: According to preset time, send message to CMS to check the panel online working status. User Manual
  • 8. 4 Product Overview 22. Voice phone alarm receiving: Alarm can via dialing user’s preset phone number, to tell user alarm information. 23. Spot siren optional: Built-in siren, and our wireless high siren, both of them can set on or off according to user’s demand. 24. Voice speaker volume adjustable: Long press 1 to enter volume setting, press to plus, press to minus. 25. Wire/wireless zone realtime monitor: Enable the option, while arming or disarming, voice will indicate zone trouble status. 26. Wireless repeat relay function: Our made wireless repeater can achieve panel receiving signal from detector more stable . 27. Wireless detector low battery warning: When detector battery undervoltage, it will send status report to panel every 1 to 2 hours, if alarm situation happens, LCD screen will display corresponding zone number and battery low voltage icon to remind user, and report to CMS. 28. Press SOS key on the panel or remote to set panel built-in siren whistle or not. (Refer to 00 zone siren type) 29. During panel remote operating, enter 4-digit user password firstly, in case unauthorized user to operate it. 30. Networking: PSTN and GSM two networks available, which one priority in use is up to user. 31. Wireless door bell: Optional( this option takes up one zone) 32. GSM phone call function 33. RFID card SMS programmable 34. Support spot 15s recording function 35. Support portable mobile device APP software control. User Manual
  • 9. M D Y M D Y SOS RFID 1 ~ 0 LCD Screen Arm Disarm Home Arm Time Date Sending Alarm Sending to mobile RFID Card Sense Area Panic key Alarm indicator Fault indicator One / Volume Arm/Up key Disarm/Down key 5 M D Y 1 2 3 4 7 5 8 0 6 9 SOSRFID + - Numeric Keyboard Confirm Zone Setting LCD Screen Alarm Indicator SOS Play Fault Indicator Record Dial Key Back Panel RFID Card Area Home Arm/Pause Event Query/Delete Product Overview 1.2 About Panel 1.3 About Icons Away Arm/Up Disarm/Down Siren whistle GSM network signal Terminal Power SOS TEL-line status Alarm indication Panel Power Numeric keys Home arm/ Pause Key Event query/Delete key Back Confirm Zone setting Record Play Dial key User Manual
  • 10. 6 Bracket Mounting Knockout Install Direction Mounting Hole Installation& Wire Connection Chapter 2 Installation & Wire Connection 2.1 Open the box Open the package to check accessory missing or not (refer to Accessory List), if you have found accessory missed, please contact local distributor or supplier immediately. 2.2 Install the control panel An obvious advantage of AD830 alarm setup that it can be installed no need to open. Cross the wire-way on the back of panel, user can easily connect all wires. 1. Remove the bracket on the back of panel. As picture shows: Push the bracket along the arrow pointed Remove the bracket Note: Insert SIM card in off-power status 2. According to the screw hole on the bracket, drill holes and fix the bracket on the wall 3. Glue the 3M adhesive on the panel back, then stick the 3M panel on the wall. User Manual
  • 11. Metal 10k 10k 7 10k 10k 12V GND BELL+ GND Z33 Z34 COM COM Z35 Z36 NC(Recommend) Wired siren( ≤350mA) LINE TEL Correspondence external wire Telephone POWER:DC15V 2A Installation& Wire Connection 1. Please don’t put large metal articles around the panel, in case to influence wireless detector receiving signal. 2. Please install the panel within the invalid distance that can normally receive signal from detector, and better putit in a covert place. As the below picture shows: Hang the panel on the bracket. 2.3 Wire Connection (wired zone support NO or NC detector) Panel external devices as below: NO Output DC12V Warning: All connectors have power limited! User Manual
  • 12. 8 Installation& Wire Connection 2.4 Install wired detector 2.4.1 Wired zone has defaulted as bypass status, user can modify it into effective status if necessary. If wired zone faulted while arming, user will hear “Operation failed, zone fault”. And the LCD will display the fault zone number+ E, now better not to arm. 2.4.2 The panel can power 12V, 700mA to detectors, don’t exceed 700 mA max current, or detector need adopt extra DC12V backup power. 2.5 Install wireless detector 2.5.1 As the detector’s manual states, install coded detector in the open area 100~120m away from the control panel. Please take a walk test, make sure the detector can work with control panel normally. 2.5.2 Wireless repeat relay function: When wireless detector is too far or blocked by wall, the panel will disable to receive signal from wireless detector, now you can use our manufactured wireless repeater relay to achieve wireless signal relay transmitting. User Manual
  • 13. 9 3.1 Choose GSM and Tel-line Priority 3.2 Check GSM Signal Status 3.3 Exit setting Press key, to exit setting status Check gsm signal status, refer to the icon on the top right corner of the screen. 01 02 GSM Priority Setting Set SMS language Note: 123789 is installer password, real operation please subject to modified Tel-line Priority GSM Priority 1 2 GSM Setting&Operation Chapter 3 GSM Setting&Operation GSM Menu Press [ ] >3s+[123789 ]+[8] Press [ ]>3s+[123789 ]+[8]+[1]+ Setting is saved Choose 1 as tel-line priority model, GSM standby. Panel alarm prefer tel-line firstly to send CMS alarm information and dial voice phone no. If tel line cut off or failed, GSM will take place of it to send CMS report and send message to user! Choose 2 as GSM priority model, tel-line standby. When this function open, panel will prefer GSM firstly to report CMS alarm information. And send all information to all preset voice phone by SMS. Set arm/disarm report to CMS effective if need to remind user arm or disarm by SMS, operation refers to Page41! If GSM phone under deficit, or signal disturbed, tel-line will replace it to give CMS report and dialing voice phone. . User Manual
  • 14. 10 3.4.1 GSM Alarm Receiving Panel alarming, GSM sends message firstly, then dial user’s phone number, user will hear “ system alarm, please receive alarm, cancel alarm press 1, alarm event query press 2, system away arm press 3, disarm the system press 4, system home arm press 5, open the siren press 6, monitor the spot press 7, hang up please press 0 ”. Then press 2 to check, voice indicates “xx zone alarm”, only after confirmed it mistake alarm can user delete alarm, and press 1 to end alarm. If operate successfully, follow with voice prompt “operation succeeded”, if not, do it again. Hang up please press 0 ahead. If user no press 1to cancel alarm, and press 0 before hang-up, the panel will dial next voice phone no. (Repeat 5 times if only one phone number and preset dial time is 5) 3.4.2 GSM Remote Operation User via phone dial the panel GSM to achieve remote control of system arm/disarm and status query. Dial GSM card number, enter password after off-hook, default: 8888, real operation subjects to modified. Follow voice prompt “System away arm press1, disarm the system press 2, system home arm press 3, system status query press 4, spot intercom press 9, hang up please press 0”. If operate successfully, user will hear prompt “operation succeeded”. 3.5 GSM SMS Control Mobile SMS Arm Command: #pwd8888#Arm Mobile SMS Disarm Command: #pwd8888#Disarm Mobile SMS Home Arm Command: #pwd8888#Home Mobile SMS Status Query Command: #pwd8888#Check GSM Setting&Operation 3.4 GSM Alarm Receiving& Remote Operation Details please refer to this manual 4.3 and 4.4 from Page17 to18 Note: User default password is “8888”, password “8888” no space in it, password is the user modified , when mobile message sent to GSM card of alarm panel, only enrolled mobile number or message wrote right password will receive system reply, others won’t. User Manual
  • 15. 11 GSM Setting&Operation 3.6 RFID Card SMS Editing By the programmed message text, panel sends out system disarm or home arm message when swiping card. For example: Children went back home and swiped the 16th card, system will disarm and send out a message of “Children back home, system disarm ” to the user preset mobile number Operate as: Use the enrolled phone number to send SMS command to alarm panel GSM card. The format as : (Remarks: is an English character, within 60 words )“” Eg.: #pwd8888#MsgRFID01: “Children back home, system disarm ” (Note: Please set RFID card function before to use, details please refer Page40 ) 3.7 Alarm Panel GSM Phone Call Function Panel can used as phone call under status, operate as: press panel icon, enter the phone number to dial, press key to confirm, press to hang up after call end. 3.8 Common GSM Suggestions 1.As panel connected to power, open GSM function, if screen appears as (the icon blinking), indicate that SIM is searching for network , last one minute or so, these are normal phenomena. But they if appeared before to use then you must check the power. GSM panel can work normally only with at least 1.5A power. If power is lower than 1.5 A, GSM restart or disable to send message to CMS. 2. Please install the panel away from iron, air-conditioner, and big machines. 3.We suggest to test GSM network at least 1 time per week, to make sure GSM working normally. If not, please check SIM card owe money or not, whether it enrolled success- fully. Or turn off AC power and close the panel to restart. User Manual
  • 16. 12 32 01 02 03 04 05 06 07 08~31 Easy Setting &Operation Chapter4 Easy Setting&Operation 4.1 Factory Default Setting Below are factory defaults of AD 830 Alarm Control Panel, you can keep the defaults or modify them. GSM function: Enabled Installer password: 123789 User password:8888 Entry and exit delay: 10s Monitoring time: 10s Cycle alarm dialing: 5times Auto off-hook ringing: 7 times (After ringing 7 times panel will pick phone automatically) TEL-line off inspection function: Enabled Auto timing arm/disarm option: Disable Auto timing arm, disarm and inspection time: 00 (The function disabled) Alarm types with siren whistle: Delay, indoor(burglar), perimeter, emergency and 24-hour alarm. All phone no and user code: Empty Siren type of panic zone: Mute Wired zone factory default: Disable Zone Factory Default Zone Alarm Type Siren Table 1: Perimeter Delay Indoor Indoor Emergency 24-Hour Fire Perimeter Perimeter On On On On Off On On On On Zone Default List Door bell zone: (Optional) Give “ding dong” sound if triggered, occupys one zone Indoor(Burglar) zone: Enabled only when system under away arm status Perimeter/delay zone: Enabled under arm and home arm status Gas, fire, emergency zone: Enabled under both arm and disarm status User better not to set zone siren silent Delay zone: Mainly applied in zones with entrance or exit. User Manual
  • 17. 13 M D Y M D Y LCD Screen Arm Disarm Home Arm Time Date Sending alarm Sending to mobile Siren whistle Network signal Terminal Power SOS Wire status Alarm indication Panel Power Considering the convenience of user, the product preset defaults to meet most users demand, so common user just do some simple jobs before to use. Please refer to the follow description, install panel and wireless devices, and connect network to panel. This chapter illustrates how to use the panel, let you get to know how to operate and test it before installation. Zone Fault Indication: Zone+”E”-----------Zone fault (Wired zone) Zone+battery icon ---Wireless detector low battery fault Easy Setting&OperationUser Manual
  • 18. 14 Easy Setting&Operation 4.2 Basic setting & operation Basic setting: The panel has already coded with all remote controllers, magnetic contacts, and pir detectors before left factory, they can auto enter into networking status when connect to power. Enter system main menu: Press key for 3 seconds, then enter installer password 123789 Enter system sub-menu: Just to press relevant numeric key. Return to previous menu, press key. System menus all have voice indication, enter main menu the panel will sound all menus option one time. Press [up], [down] key or corresponding number also have voice prompt, more friendly and easy to use. After setting press key to save, you will hear “Setting is saved” , means operate successfully, or failed. On the keyboard from up to down there are four buttons with normal functions [Away Arm], [Disarm], [Home Arm], [Event Record Query], while under system setting status, they function as [Up], [Down], [Pause], [Delete]. The numeric keys on keyboard are for user to enter numbers, key is back, key is confirm. Under panel standby status, press [SOS] key for 3 seconds is to seek emergency help. Indicator: Alarm indicator-----light blinking Fault indicator------Indicator light blinking when zone faulted RFID card indicator-----Indicator light blinking for 3s when swiping card Basic operation: Power on/off—When power on AC, system battery auto activated, when AC power off, enter key for 3s+[4-digit user password]+ press 3s, then panel turns off. When battery lower to 9.2V, system will turn off automatically to protect the battery. System setting—long press no less than 3 seconds+ [6-digit installer password]+ System disarm—[4-digit user password]+ , or [4 user password]+[ ] User Manual
  • 19. 15 1 2 3 4 5 6 7 0 User Operation System will sound voice indication of setting option when enter into a menu, press number to enter option setting, system will voice indicates setting details, press confirm key or press the option 2 times to enter into this option submenu. 4.3 Common Voice Phone Alarm Receiving When delay zone detector triggered, the panel will sound warning tone, if none of disarm operation during the period, after pre-alarm panel will make alarm by dialing the preset voice phone number in turn. After repeat several times and voice prompts if still no one to receive alarm or do ineffective operation, then panel will continue to alarm . If phone call get connected, user has made effective operation but without press 1 to delete alarm and no press 0 before hang-up, the panel will continue dial other preset phone number. Voice Phone Alarm Receiving alarm report off-hookThe panel will dial preset voice phone number Play the recorded voice message first, then sound: Cancel alarm press 1 Alarm event query press 2 System away arm press 3 Disarm the system press 4 System home arm press 5 Open the siren press 6 Monitor the spot press 7 Hang up please press 0 4.4 Remote Phone Control User can remote control the system via phone. Dialing panel connected phone no, after preset ringing times no answer the panel will off hook the phone, follow voice prompt, enter correct 4-digit user password, now user can operate the panel by phone. M D Y 1 2 3 4 7 5 8 0 6 9 SOSRF ID + - # M D Y 1 2 3 4 7 5 8 0 6 9 SOSRF ID + - # M D Y 1 2 3 4 7 5 8 0 6 9 SOSRF ID + - # M D Y 1 2 3 4 7 5 8 0 6 9 SOSRF ID + - # M D Y 1 2 3 4 7 5 8 0 6 9 SOSRF ID + - # M D Y 1 2 3 4 7 5 8 0 6 9 SOSRF ID + - # User Manual
  • 20. Panel 16 1 2 3 4 X X X X 0 M D Y 1 2 3 4 7 5 8 0 6 9 SOSRF ID + - User Operation MobileMobile Telephone User call landline phone number The phone will ring 7 times. After that the panel will off-hook automatically. Follow voice prompt , enter the user password, now remote control panel. Press 3 seconds, enter[8888 ] Enter the user password 4-digit user password System away arm press 1 Disarm the system press 2 System home arm press 3 System status query press 4 Hang up please press 0 4.4 CMS Alarm Receiving The panel use Ademco Contact ID protocol to send alarm information to CMS. If the panel gets a confirm from the center, then alarm successfully. Or panel will repeat alarm(redial times preset). The computer software of CMS displays alarm information and handles the alarm. 4.5 Alarm Procedure Only the zones set burglary, delay and perimeter alarm types, under away arm, stay arm and disarm operations, other types zone can alarm normally for whole 24 hours. * # User Manual
  • 21. 17 wired 2.A stands for zone alarm, 00 is zone number. M D Y User Operation Alarm Procedure Diagram: CMS Telephone Telephone Mobile 3.After CMS, the panel will dial no1-4 telephones as prest.And spot siren will sound if preset. If alarm more than 2 times, then recycle alarm follow the second and third steps. wireless Telecomnetwork Alarmsoftware Alarm situation found, start to send message 1.Detectors activated and send alarm infromation to alarm center alarm center Receiver 2.The panel sends alarm information received to alarm center computer wireless LCD Display: 1. Digital display zone number, wired zone no: 33~36, wireless zone: 1~30, the 00 zone is panel or remote W ireless M D Y 1 2 3 4 7 5 8 0 6 9 SOSRF ID + - # M D Y 1 2 3 4 7 5 8 0 6 9 SOSRF ID + - # M D Y 1 2 3 4 7 5 8 0 6 9 SOSRF ID + - # M D Y 1 2 3 4 7 5 8 0 6 9 SOSRF ID + - # M D Y 1 2 3 4 7 5 8 0 6 9 SOSRF ID + - # M D Y 1 2 3 4 7 5 8 0 6 9 SOSRF ID + - # User Manual
  • 22. M D Y 18 User Operation 4.7 Telephone-line Off Alarm Under arm status, the siren will whistle immediately once the panel detects the telephone line cut off. Under disarm status , the panel will give voice about to tell detected tel-line cut off for about 60 seconds , and during the period, if the tel-line connected again or disarm the system, indication voice will stop, if not, the siren begins to whistle. (LCD display as picture below) 4.8 Wireless Detector Anti Tamper Alarm 1. When the panel received a signal from wireless zone detector that anti tamper switch opened, if under arm status, the panel will solve it as burglar alarm(via status code and burglar alarm type the detector received). Then only received the signal that the anti- tamper switch closed can the system continue to solve anti-tamper alarm situations. 2.Anti-tamper switch alarm indication: Screen displays wireless detector zone number, and burglar icon. 4.9 System Event Record&Query 4.9.1 Event record: Options: Burglar, away arm, stay arm, disarm, tel-line off, low battery, low battery restoral setting such information. Wireless detector (include magnetic contact) low battery monitoring function: When wireless detector battery is under voltage, the panel shows low battery icon, for example, zone number is “16”, represents the 16th zone detector battery undervoltage. Then alarm panel will send this information to alarm center, remind the system administrator or user to change battery in time, so detector can keep working normally. If replaced with new battery, detector will send undervoltage restore information to alarm panel, then panel back to normal work status. the icon blinking means tel-line off User Manual
  • 23. 19 When the AC power off, Fault Indicator blinking, if still no restoration after AC power off delay setting, then AC loss reported to alarm center, and dial user’s phone, after AC power restored about 1 minute, alarm center receiver will receive signal of AC supply again . User Operation 4.9.2 Event Query Press [Query] key to check the event recorded. Press the [Query] key continuously can acquire the previous records in chronological. Press [Up], [Down] keys to navigate, [Back] key to exit, if no any operations within 20s, the system will exit query status automatically. For example: Burglar alarm at the 5th wired zone at 0:12 AM 30th November, 2013 Press “Query”key Voice Prompt: At 00:12 AM the fifth zone alarm. Screen will display date, zone no and alarm type. Press Query key to check next event record 4.9.3 AC Power Off and Restoral Inspection Function (Refer to page41 to see details) User Manual
  • 24. 20 Press disarm key on the remoter,or enter user passwod +[ ] on the keyboard, your will hear “dee” and voice“System Disarmed” means disarm successfully. M M M MD D D D Y Y Y Y 1 1 1 12 2 2 23 3 3 3 4 4 4 4 7 7 7 7 5 5 5 5 8 8 8 8 0 0 0 0 6 6 6 6 9 9 9 9 SOS SOS SOS SOSRF ID RF ID RF ID RF ID + + + + - - - - User Operation 4.10 Easy Operation Away Arm Disarm Dee Dee Dee Dee Press key for away arm key on remoter or keyboard, then hear “System ,pleasearm exit the zonearming ”,and “dee, dee” sound means delay end, system arm succeeded. Home Arm SOS Dee Dee Dee Dee Press home arm key on remoter or the keyboard, then hear :“System home arm”, on the LCD display arm icon means home arm setting saved. Press panic key on remoter, or press “SOS” key 3 seconds, the panel will send alarm signal and make alarm according to preset methods. After the operations above, please browse the “Event Query ” chapter in this manual if you want to check relevant operation records. # # # # M M M MD D D D Y Y Y Y 1 1 1 12 2 2 23 3 3 3 4 4 4 4 7 7 7 7 5 5 5 5 8 8 8 8 0 0 0 0 6 6 6 6 9 9 9 9 SOS SOS SOS SOSRF ID RF ID RF ID RF ID + + + + - - - - # # # # M M M MD D D D Y Y Y Y 1 1 1 12 2 2 23 3 3 3 4 4 4 4 7 7 7 7 5 5 5 5 8 8 8 8 0 0 0 0 6 6 6 6 9 9 9 9 SOS SOS SOS SOSRF ID RF ID RF ID RF ID + + + + - - - - # # # # M M M D D D Y Y Y 1 1 1 2 2 2 3 3 3 4 4 4 7 7 7 5 5 5 8 8 8 0 0 0 6 6 6 9 9 9 SOS SOS SOS RF ID RF ID RF ID + + + - - - # # # M M M D D D Y Y Y 1 1 1 2 2 2 3 3 3 4 4 4 7 7 7 5 5 5 8 8 8 0 0 0 6 6 6 9 9 9 SOS SOS SOS RF ID RF ID RF ID + + + - - - # # # M M M D D D Y Y Y 1 1 1 2 2 2 3 3 3 4 4 4 7 7 7 5 5 5 8 8 8 0 0 0 6 6 6 9 9 9 SOS SOS SOS RF ID RF ID RF ID + + + - - - # # # User Manual
  • 25. 4.11 RFID Card SMS Editing(Please refer to page11in this manual) 4.12 Alarm Panel GSM Phone Call Fucntion(Please refer to page11in this manual) 4.13 Mobile APP Function(Please refer to page22~23in this manual) 4.11 GSM SMS Operation (Please refer to page10~11in this manual) User OperationUser Manual
  • 26. APP Software 4.14 APP Software Note: Please download the AD 830 Alarm Control APP software to mobile terminal. Eg.: 1. Enter panel SIM card no at the log-in page phone no option 2.At the panel password option enter any one from 6 group user password. Default 4-digit user password:8888 We suggest user to modify the password in time! 3. Click “OK” button, enter the function option 1.The 2nd page of function setting, option and interface as right picture 2 Swipe the screen left , enter the 3rd page. 1.The 1st page of function setting, specific option and interface as left picture shows. 2. Swipe the screen left, enter the 2nd page 1. The 3rd page, specific option and interface please see picture left. User Manual
  • 27. APP Software Eg.: 1. Enter panel SIM card no at log-in page. 2.At host password option enter any one from16 group user password. Default 4-digit password:8888 Please modify the password in time! 3. Click “OK” button, enter the function option 1. Remote manual enroll function, enroll the remote ID number in the panel. So remote can operate panel. 2.User phone no. setting function, hold 4 phone no, when alarm situation happens, the panel will auto send report to user phone number. 3.RFID card manually enroll the RFID card serial number in the panel, so RFID card can operate the panel. 4.Other functions under developing! 1.After log-in, enter the page as left. Click the according function option (eg.: away arm) 2.Then popup “away arm” text indication! And send an arming message to panel. 3. The other function settings as the same. 1. SMS setting option of swiping card can bind the card no with specific content message. While swiping card, the panel will send preset message to according phone no. 2.Entery/exit delay setting option, enable to set entry and exit delay time under arm status. 3. Siren ring time and volume, enable to set ring time and volume. 4. Master password setting option, enable to modify the password. 5.Other functions underdeveloping. User Manual
  • 28. 3 Set User Phone Number 1 Clock Setting 2 Set User Password Please enter the password number to modify, press“ ”key to save, press “ ” key to exit. Please enter new password, press “ ”key to save, press “ ” key to exit. 1 3 8 8 8 8 8 8 8 8 Factory Default User Password 11 3 0 21 0 0 4 5 01~16 1~4 New User Password [XXXX] +[#] [2]+ Set user phone no 1 press 1, set user phone no [3]+ 2 press 2, set user phone no 3 press3, set use phone no 4 press 4, set user phone dial time press5. Exit the setting press key. + Note: Exit the setting press[ ]key Exit the setting press[ ] key Press[ ] +[0]+[ ]Note:0 is set off, 1 is set on +[1]+[ ] Press to set phone number User Operation Chapter 5 User Setting User Menu Press[ ] ( > 3 s) [ ] 5.1 Clock Setting Please enter the system time, press“ ”key to save, press “ ” key to exit. Setting is saved According to flash of Y.M.D.H.M on screen, enter 13, 11,30, 00, 12 45 by turn, or by [Up] and [Down] keys to move cursor. 5.2 User Password Setting +[x]+[xxxxxxxx]+[ # ] 5.4 Zone Attribution Setting(enabled or disable) 5.3 User Phone Setting(Support 4 groups user phone number) Bypass press 1, cancel press 0 or M D Y M D Y M D Y # # # Please enter the zone number to modify, press“ ”key to confirm, press “ ” key to exit. Please note: If panel has GSM card, please operate it after 3 minutes power on . User Manual
  • 29. Set system on the keyboard, press to save, press to exit setting. System Setting Chapter 6 System Setting This chapter will introduce the function setting of AD 830 series alarm panel, you can set it according to your demand. If all settings finished, the panel must restart! We will not be responsible to the problems caused by user’s incorrect operation! 6.1 Setting Instruction Every time press a key the panel will sound effective indication speech. Every time finish an operation wrong or right , the panel will sound corresponding indication speech. If setting under submenu, press [ ]back to main menu, to continue other setting. Under disarm status, press [ ] 3 seconds to enter setting status.“please enter the password”, enter correct installer password , according to indication, input relevant option setting command, every time enter correct command please press[ ] to enter into the submenu, follow the voice, enter the option to be modified, the screen will display the default or the setting user programmed before, for user to decide to alter previous setting, now can input the new value, press [ ] to confirm, or directly press [ ] to save former setting. After this operation, the screen will back to status o f entering command so that the user can carry on next option setting. When you finished all settings, press[ ] to exit. If after 5 minutes no any operation the panel will exit setting automatically. Only under disarm status, can enter system setting by pressing [ ] for 3s. If with incorrect operation during setting you can press[ ] back to previous menu anytime. 6.2 Main Menu Setting Let’s learn how to enter system and function of each options. All pane setting can refer to this method, and the panel will keep memory of the setting to work until you modify it again. User Manual
  • 30. 8 9 7321 1 2 4 3 5 6 7 1 XX M M M M 2 Set user password press one MM M M M M Setting is saved Setting is saved 8 9 Password setting CMS setting User phone setting System option setting Enroll wireless device Zone setting System manitenance Other setting High-level setting Please enter the password number to modify, press“ ”key to confirm, press “ ” key to exit. Please enter new password, press“ ”key to confirm, press “ ” key to exit. Set installer password press two Max.16 groups user password Under disarm status press key( > 3 s) to enter main menu System Setting Main Menu Commands Please enter the password 6.3 Password Setting Password consists of “user password”and “ installer password”, “user password” is user’s private “key” for keyboard disarm or remote control operation, in order to guarantee your system safety, please set the 4-digit user password convenient to remember. “installer password” is the only password to set the system, please keep it in mind if modified, otherwise you can’t operate the system. Password Setting Please enter new password, press “ ”key to save, press “ ” key to exit. Press [ ] (>3s) +[123789 ]+[1], follow the voice indication to operate. Please note: If panel has GSM card, please operate it after 3 minutes power on . User Manual
  • 31. 1 2 3 7 8 9 21 1 2 3 6 5 4 Please enter new password, press“ ”key to confirm, press “ ” key to exit. Example1: Modify the installer password as“123654” System Setting Press key (> 3s) Please enter the password Setting is saved Please note: 1. Above are based on correct operation, if incorrect operation occurs, please press [ ] back to previous menu to reset. 2. The installer passwords introduced to guide here all are the factory preset default password [123789], password please subject to the modified. User Manual
  • 32. # X X X X 1 2 3 4 5 1 X 2 3 4 X X X X X 5 Set CMS phone No 1 press 1 Set CMS phone No 2 press 2 Please enter the phone no, press delete key to clear, pause key delay 1s to dial out, press “ ” to save, press “ ” to exit. Please enter the user number, press“ ” to save, press “ ” to exit. Set CMS user number press 3 Set CMS communication test time press 4 Set CMS dialing time press 5 CMS network alarm should be authorized by local security service company, common user do not use it! CMS Setting System Setting 6.4 CMS Setting Press [ ] (>3s)+[123789 ]+[ 2 ], then operate as the following voice indication. Setting is saved Setting is saved The CMS user number is user’s identification code in the CMS Please set panel CMS user number after CMS phone number setting. User code should be 4 digit. When set CMS phone number, please press “ ” to delete previous data, if with extension number, press one time to hold on 1second.(for operator transfer to extension telephone ) Arm disarm report to CMS, this function factory default is disable, if need CMS network alarm, please refer to page 41. Please enter the CMS COMM test time, enter 0 means no test, press“ ” to save, press “ ” to exit. Please enter the dialing time press “ ” to save, press “ ” to exit. (hour) Setting is saved Setting is saved User Manual
  • 33. 1 2 3 4 5 0 5 1 2 3 37 98 7 6 5 4 3 2 01 1 6.5 User Phone Setting Set user phone No1 press 1 Set use phone No2 press 2 Set use phone No3 press 3 Set use phone No4 press 4 Set user phone dialing time press 5 Please enter the dialing time press “ ” to save, press “ ” to exit. Setting is saved Setting is saved Please enter the phone number, press delete key to clear, pause key delay 1s to dial out, press “ ” to save, press “ ” to exit. X X X X XXX X XXX X X XX X X Please do not set government public alarm phone no as individual alarm receiving station, otherwise, users take charge of all negative effects and legal obligation. Note: Max 17 digits number System Setting Press [ ] >3s+[123789 ]+[3], follow the voice indication to operate. User Phone Setting Example 2: The panel connect to one phone call, voice alarm receiving phone is local number: “76543210”, if want to set it as the No1 voice phone:(Pls note: non-local tel number should add local area code ahead, non-local mobile phone add 0 ahead.) Press ( >3s) Please enter password Please enter the phone no, press delete key to clear, pause key delay 1s to dial out, press “ ” to save, press “ ” to exit. Setting is saved User Manual
  • 34. Clock setting Entry delay setting Exit delay setting Set remote arm/disarm tone Set siren time Set phone off-hook ringing time TEL-line off detection setting AC loss inspection time setting Zone faulted arming setting 8 92 81 73 1 2 4 3 5 6 7 1 2 3 4 6 4 9 9 7321 8 9 4 1 1 3 1 1 3 0 0 0 1 2 Please enter the system time, press to save, press to exit 6.6 System Option Setting 6.6.1 Clock Setting For example:set system to 0:12 30th, Nov, 2013 System Setting Press [ ] >3s+[123789 ]+[4], follow the voice prompt to operate. Press [ ] > 3s Operate as: [ ] 3s [ password] [ ] [4] [1] [year]installer [second][month] [day] [hour] [minute] [ ] Press [ ] > 3s According to flash of Y.M.D.H.M on screen, enter 13, 11, 30, 00, 12, 45 by turn, or by [Up] and [Down] key to set. Setting is saved Save setting Hints: For user to acquire real alarm time, please set the time as local. M D Y M D Y M D Y # User Manual
  • 35. 6.6.4 Set Remote Arm /Disarm Tone: the setting of siren indication sound or not during the period of remote controller arming or disarming (default: no indication ) For example: Set remote arm / disarm tone indication as siren short sound. 6.6.5 Set Siren Time: The siren sounding period after panel start to alarm. (Default setting is 5 minutes) For example: set the delay time as 12 minutes(better no more than 12 minutes) 6.6.6 Set Phone Off-hook Ringing Time: The ringing time of panel off-hook when user phone dial to panel phone number for remote control. For example: Set off-hook ringing 5 times 4 4 Please enter the siren time from 0 to 30 minutes. Press “ ” to save, press “ ” to exit. Please enter the ringing time, 0 means no off-hook. Press “ ”to save, press “ ” to exit. 1 1 2 0 5 Please select arm/disarm tone: 1. siren short sound 2. no indication. Press “ ” to save, press “ ” to exit. 97321 8 7321 8 9 4 5 7321 8 9 4 6 System Setting Press [ ] > 3s Setting is saved Press [ ] > 3s Setting is saved Enter 2-digit number from 0-30, add 0 ahead if lower than 10 Press [ ] > 3s Setting is saved Press 2 digit number from 0-15, add 0 ahead if lower than 10 Remark: The ringing time can be set from 0 to 99, the maximum value based on local condition, when set as 00, means remote phone control disable. . User Manual
  • 36. 7321 8 9 9 4 4 2 3 0 0 5 0 7321 8 0 3 Please enter the entry delay time, press to save, press key to exit. Please enter password Please enter the exit delay time, press to save, press key to exit. System Setting Press [ ] > 3s 6.6.2 Entry Delay Setting: Panel delay alarming period after alarm triggered. (Default value is 10s) E.g: Set the delay time as 5s Setting is saved Please enter 3 digit number from 001 - 225. 6.6.3 Exit Delay Setting: The period from user arm system on keyboard or remoter, to system successfully armed and exit setting.( Default value is 10s) For example: Set delay time as 30 s Press [ ] > 3s Setting is saved Please enter 3 digit number from 001 - 225. Note: Entry delay enabled only in entry/exit zone. Exit delay enabled only in perimeter, burglar, delay zone. User Manual
  • 37. 1 0 1 5 0 6.6.7 TEL-line Off Detection Setting: Detect the telephone line whether connect normally, it will alarm if not. ( Default: )detect tel-line For example: Set tel-line with detection. 6.6.8 AC Loss Inspection Time Setting: The panel will send the inspection time to CMS and user after AC loss. 6.6.9 Zone Faulted Arming Setting: Set arm function effective or not under zone trouble status.(factory default: disable) For example: Set zone faulted arm function enabled. 7 7 7 3 3 3 2 2 2 1 1 1 8 8 8 9 9 9 4 4 4 7 8 9 Please choose: 1. detect tel-line 2. not detect Press to save, press to exit. Please choose: 1. Enabled 2. Disable .Press to save, press to exit Please enter the AC loss inspection time from 0 to 255 minutes, zero means no inspection. .Press to save, press to exit Press [ ] > 3s Setting is saved Press [ ] > 3s Setting is saved Press [ ] > 3s Setting is saved System SettingUser Manual
  • 38. 7 7 3 3 2 2 1 1 5 5 1 2 8 8 9 9 1.Remote controller code study 1.Detector code study 1.wireless siren code study 1.RFID card code study 2.Enter remote controller code 2.Enter Detector code 2.wireless siren code delete 2.RFID card code delete 3.Remote controller code delete 3.Detector code delete Enroll Remote controller Enroll Detector Enroll Wireless siren Enroll RFID card Please enter the remote number. Press “ ” key to confirm, press “ ” key to exit. Please enter the remote no. Press “ ” to confirm, press “ ” to exit. Please enter the remote code. Press “ ” to confirm, press “ ” to exit. 3 7 (1)Auto Enrolling: (2)Enroll Manually 3 0322 2 01 5 Please trigger the remote to enroll, press key to exit Setting is saved 7321 5 1 58 9 Trigger Remote Arming key Press “ ” key to save, press “ ” key to exit. For example: enroll the third remote in the panel automatically. For example: Set the 7th remote address code:223321005, manually input into the panel. 9-digit address code 6.7 Enroll Wireless Device 1. 2. 3. 4. System Setting Press [ ] > 3s Please follow the voice prompt to operate We suggest user to enroll all devices by manually entering codes. 6.7.1 Remote Controller Enrolling and Delete Press [ ] > 3s Press [ ] > 3s Setting is saved User Manual
  • 39. 1 1 2 5 (1)Auto enrolling (2) Manually enrolling (3).Delete Remote Code 6.7.2 Detector Enrolling and Delete 1 8 7 7 7 3 3 3 2 2 2 1 1 1 8 8 8 9 9 9 5 5 5 1 2 2 3 1 2 Please enter the remote number to delete, enter zero to delete all remoter. Press “ ” to confirm, press “ ” to exit. Please enter the detector no. Press “ ” key to confirm, press “ ” key to exit. Please enter the detector no. Press “ ” key to confirm, press “ ” key to exit. Please enter the detector no. to delete, enter 00 to delete all detectors.. Press “ ” to save, press “ ” to exit. Please enter the detector code. Press “ ” key to save, press “ ” key to exit. Please trigger the detector to enroll, press key to exit 6 7321 8 9 5 2 3 E.g: Delete the 6th remote controller Example: manually input the address code:223321006 into the panel 15th zone 3 0322 2 01 6 9-digit address code System Setting Press [ ] > 3s Setting is saved Setting is saved Example: Delete the 18th detector Example:Enroll the wireless detector in 12th zone Press [ ] > 3s Setting is saved Press [ ] > 3s Press [ ] > 3s Setting is saved Press “ ” to save, press “ ” to exit. 35 User Manual
  • 40. 6.7.3 Enroll Wireless Siren 3 3 3 2 2 2 1 1 1 2 2 0 0 0 4 4 4 5 5 5 5 5 5 3 4 4 1 1 1 0 0 0 Please set the siren to enroll, press to begin. Return to the previous menu press key. Please enter the RFID card number to enroll, press to confirm, press key to exit. Please enter the RFID card number to delete, press to confirm, press key to exit. Siren begin to enroll, please enter the next step after voice prompt. Return to the previous menu press key. Please put the RFID card on Induction Area Please confirm the RFID card number to delete. Press “ ” key to save, press “ ” key to exit. Setting is saved Setting is saved Setting is saved trigger the siren to enroll Press “ ” key to save, press “ ” key to exit. Press “ ” key to save, press “ ” key to exit. System Setting For example: Press [ ] > 3s Press [ ] > 3s Press [ ] > 3s Press the wireless siren SAVE key and hold on until the siren whistle that the siren successfully enrolled, press[ ] to exit. Or refer to relevant siren operation guide. 6.7.5 RFID Card Study Function 1. Enroll RFID Card#02 6.7.4 Delete Wireless Siren: Please refer to voice prompt. 2. Enroll RFID Card#02 . User Manual
  • 41. 1 2 3 4 X XX X 0 1 2 3 4 5 6 Please select zone type: 0. Disable 1. delay zone 2.perimeter zone 3. Indoor (burglar) zone 4.SOS zone. 5. 24-hour zone. 6. fire zone. .Press to save, press to exit Please select siren type: 1.pedal point 2.pulse tone 3.mute Please select siren type:1.pedal point 2.pulse tone 3.mute Press to save, press to exit. IndoorZone FireZone 24-hourzone Note: 00 is only used as the SOS key on the panel or remote System Setting 6.8 Zone Attribution Setting Press [ ] >3s+[123789 ]+[6], follow the voice prompt to operate. Zone Attribution Setting Set sos siren type press 3 Set zone door contact open detection press4 Please choose: 1.Detect 2. Not detect Press to save, press to exit. Setting is saved Setting is savedSetting is saved SOSZone PerimeterZone DelayZone Disable Setting is saved Indoor(Burglar) Zone: Enabled only at system away arming status. Delay, Perimeter Zone: Enabled only at system away arming or stay arming status. Set zone attribution press 1 Please enter the zone no. to modify. Press to confirm, press to exit. Set zone siren type press 2 Please enter the zone no to modify. Press to confirm, press to exit. User Manual
  • 42. 42 31 5 Set timing arm/ disarm press 1 Record alarming voice message press 2 Play alarming voice message press 3 Delete system log press 4 Restore factory setting press 5 Please enter timing arm disarm group number. Press to confirm, press to exit. Please confirm again! Press to save, press to exit. Please confirm again! Press to save, press to exit. Please start to record after ringing Note: record time is15 s Please enter timing arm time, 0:0 is invalid. Press to save, press to exit. Please enter timing disarm time, 0:0 is invalid. .Press to save, press to exit Setting is saved Setting is saved Setting is saved Press [ ] >3s+[123789 ]+[7], follow the voice prompt to operate. System Setting 7.0 System Maintenance System Maintenance Note: Any operation before the end of this voice prompt is ineffective! User Manual
  • 43. 9 7 1321 7 8 System Setting Example: Set timing arm at 20:30PM, timing disarm at 07:05AM Press [ ] > 3s Please enter timing arm disarm group number. Press to confirm, press to exit. Please enter timing arm time, 0:0 is invalid. Press to save, press to exit. Please enter timing disarm time, 0:0 is invalid. Press to save, press to exit. Setting is saved Hint: 4 groups of timing arm/disarm can be set according to the schedule of user User Manual
  • 44. 1 2 3 SMS language setting press 2 RFID card option setting press 3 GSM priority setting press 1 Setting is saved! Setting is saved! Setting is saved! Please choose: 1.Tel-line priority 2.GSM priority Please choose: 1.Chinese 2.English Please enter the RFID card no, .Press to confirm, press to exit Other Setting 1 X X 2 3 4 5 6 SystemDisarm SystemDisarm& SendMessage SystemArm SystemHomeArm &SendMessage SystemDisarm &DialPhoneNo1 SystemHomeArm &DialUserPhone No1 For example: After your children back to home, swip the No 03 RFID, system will disarm and send message to user phone No1, operate as below: 89 3 0 3 2321 7 8 X X Other Setting Press [ ] >3s+[123789 ]+[8], follow the voice prompt to operate. 8.0 Other Setting Press [ ] >3s Meanwhile, the user should send message to panel (details please refer to Page 11,section 3 and 8) User Manual
  • 45. 39 High-level Setting Alarm Information Delivery Methods: 0. No delivery 1. Only send message to CMS 2. Only dial user phone no 3. Dial user phone no+ Send Message 4. Only report to CMS 5. Report to CMS+ Send Message 6. Report to CMS + Dial user phone no 7. Report to CMS + Dial user phone no+Send Message Example1: After (AC Loss), dial user phone no and send message and report to CMS. Example2: After (System Disarm), report to CMS. Example3: After (System Home Arm), report to CMS. Example4: After (System Away Arm), report to CMS. 7 7 7 7 3 3 3 3 2 2 2 2 1 1 1 1 8 8 8 8 9 9 9 9 9 9 9 9 13 24 25 26 7 4 4 4 COMM Test TEL-line Off 5(Default) 5(Default) 0(Default) 0(Default) 0(Default) 0(Default) 0(Default) 0(Default) 0(Default) 0(Default) 0(Default) 5(Default) 4(Default) 4(Default) 17 16 18 19 20 21 22 23 25 26 27 28 29 30 Wired Zone Fault Wired Zone Restoral Battery Restoral Event COMM Failure Zone Bypass Restoral Alarm Cancel System Home Arm System Away Arm System Programing System Arm Failure Tel-line Restoral COMM Restoral 0(Default)24 System Disarm Alarm Type Alarm TypeDelivery Code Delivery CodeNo No Delay Zone SOS 7(Default) 7(Default) 7(Default) 7(Default) 7(Default) 7(Default) 7(Default) 7(Default) 5(Default) 5(Default) 5(Default) 5(Default) 5(Default) 5(Default) 5(Default) 02 01 03 04 05 06 07 08 09 10 11 12 13 14 15 Perimeter Zone Burglar Zone 24H Zone SOS Zone Fire Zone Tamper Zone Battery Failure Battery Restoral Zone Detector Loss Event Battery Failure Event AC Loss AC Restoral Event Bypass Event 9.0 High-level Setting: (alarm information delivery) Press [ ] >3s Press [ ] >3s Press [ ] >3s Press [ ] >3s+[123789 ]+[9], according to the following code to opearte. Press [ ] >3s User Manual
  • 46. Technical Specification Chapter 7 Technical Specification 7.1 General Data 1. Area data: 4 wired areas, 32 wireless zones, 8 remote controllers 2. Zone type: Delay, perimeter, burglar, emergency, fire, gas, key, door bell, permanent bypass. 3.Frequency: 433MHz 4. Signal transmit distance: Open area (100~120 m) 5. Power supply: 15V/2000mA 6.Built-in rechargeable battery: 11.1V/800 mA 7. Panel static current: <80 mA(12V, exclude wire detector current) 8. Panel alarm current: <350 mA/12V(exclude high siren current) 9. Panel 12V max output current: ≤ 350mA ( for wire detector) 10. Recording time: 15s 11. RF frequency: 433 Mhz 0.5MHz 12. Wired zone triggered delay: ≥700ms 13. Alarm dial method: PSTN and GSM 14. DTMF dial frequency tolerance: <1.5% 15. CMS Communication protocol: Ademco Contact ID 7.2 Physical Property 1. Operation temperature range: 0 ℃~ 45℃ (32℉ ~ 120℉) 2. Storage temperature range: -20℃~ 60℃ (-4℉~140℉) 3. Humidity: 85% RH, at temperature of 30℃(86℉) 4. Size: 200*145*32mm(L*W*H) 5. Weight: 410g(standalone, exclude the battery) 6. Color: White User Manual
  • 47. 42 Maintenance Chapter 8 Maintenance 8.1 Regular test The alarm system design on principle of saving customers’ maintenance cost, but we still suggest you to carry out “periodical test” one time every month, to guarantee the system’s working reliability. And please contact the installer immediately if you have found something wrong. 8.2 Cleaning of the control panel machine After a period of using, the control panel may be oil-stained or dust-covered. Please use soft cotton cloth or sponge to clean it. Note: Don’t use any lubricant or organic solvent, such as kerosene, acetone and super glue to clean the machine shell, in case to influence the external appearance and the top window transparency. Chapter 9 Product Limitation Although the products you bought is high standard, but there still has problems as false alarm or miss alarm, the reasons may be as below: Lack of Maintenance: The system needs maintenance and test regularly, the detector sensitivity decreasing , may result in false or miss alarm, and the siren disable to to whistle. Lack of Power Supply: If no power restore or backup power is not enough, the panel can not work normally, it can’t alarm even zone has alarm situation. Tel-line Trouble: If the telephone line is cut or short-circuit, the panel could not send out alarm signals. Limitation of Smoke Detector: Sometimes, because of house design or distance too far for the smoke detector to receive alarm signal that may cause miss alarm. System disable to receiving information: If the intruder break in through unprotected window or unknown entrance, or some one knows how to make the alarm devices disable to alarm. In order to guarantee detector and the whole alarm system to work normally, we suggest user to test it frequently. Even installed our alarm system, user still should keep caution of life and property safety. We will keep on developing new security& protection series product, please pay attention to our product update status, to get our latest technical product and relevant material. Your support is our motivation! User Manual