1. POND
EXISTING LODGE
(under construction)
EXISTING LODGE
(under construction)
EXISTING LODGE
(under construction)
LODGE
PARKING
EXISTING LODGE
SERVICES
AGRICULTURE
AREA
NATURAL
BUSH
TO BE
MAINTAINED
ROAD
MASTER SITE PLAN 1:1000
LOCATION PLAN 1:20000
DATE: PROJECT: DRAWING: SCALE:
DRAWN BY:CLIENT:
PLOT: SIGNED:
MASTER SITE PLAN 1:1000 1:20000
G H
PAGE #:
ADAM YOUNG / BAKWENA LODGE + CAMPING
BLCM-MAST-01
CLIENT ADDRESS:
NOV 2012
89/90 - RO, KAZANGULA
PAGE FORMAT: A3
DRAWING NUMBER:
/
MANAGERS HOUSE EXTENSION
FOR BAKWENA LODGE
P.O.BOX 744
KASANE
SUBMITTED:
MANAGERS HOUSE
223542
204849
41675
82589
140489
121596
13000
9853
15599
LODGE
ACCESS
EXIST.
ACCESS
PROPOSED
ACCESS
140066
waste
area
waste
area
*PROPOSED EXTENSION SHOWN IN
RED ON MASTER SITE PLAN
*SITE SHOWN IN RED ON
LOCATION PLAN
2. DGE
DATE: PROJECT: DRAWING: SCALE:
DRAWN BY:CLIENT:
PLOT: SIGNED:
SITE LAYOUT PLAN
PROPOSED EXTENSION SHOWN IN
RED
1:250
G H
PAGE #:
ADAM YOUNG / BAKWENA LODGE + CAMPING
BLCM-LAY-01
CLIENT ADDRESS:
NOV 2012
89/90 - RO, KAZANGULA
PAGE FORMAT: A3
DRAWING NUMBER:
/
MANAGERS HOUSE EXTENSION
FOR BAKWENA LODGE
P.O.BOX 744
KASANE
SUBMITTED:
MANAGERS HOUSE
EXISTING
PROPOSED
EXTENSION
LODGE
LAUNDRY +
STAFF
AREA
GATE
PARKING
AGRI AREA
POND
ROAD
LODGE
SERVICE + STAFF
PARKING
13000
9853
16230
56518
53724
5003
2500
4000
35421
17097
EXISTING
SCEPTIC
TANK +
SOAKAWAY
PATH
DRIVEWAY
45400
41870
TO
LODGE
AREAS
SITE =
LODGE =
EXISTING MANAGERS HOUSE =
PROPOSED EXTENSION =
TOTAL BUILDINGS =
EXISTING COVERAGE = 2.56%
PROPOSED COVERAGE = 0.27%
TOTAL COVERAGE = 2.83%
waste
area
5000
2500
SITE LAYOUT PLAN 1:250
3.
GG G
A
A
(cavity to be filled with
insulation to suit)
FLOOR PLAN
1:100
SECTION A-A
1:100
(see detail)
NOTE:
ALL NEW DOORS AND WINDOWS TO BE AS SHOWN ON FLOOR PLAN.
ALL GLAZING TO CONSIST 6mm FLOAT GLASS.
NEW DOORS TO CONSIST STANDARD STEEL DA TYPE WITH NDAT1 FANLIGHT ABOVE,
EXCEPT SCULLERY DOOR TO BE STANDARD RDF4 WITH HARDWOOD DOOR FITTED.
NEW WINDOWS TO CONSIST STANDARD STEEL INDUSTRIAL TYPES SS33/SS34/SS35 WHERE
SHOWN ON PLAN, EXCEPT GUEST TOILET TO HAVE STANDARD STEEL TYPE NE1.
*ALL DOOR AND WINDOW CHANGES IN EXISTING BUILDING TO BE OF REUSED WOODEN
FRAMES SALVAGED WHERE POSSIBLE.
ALL NEW PLUMBING TO PIPE INTO EXISTING WASTE WATER SYSTEM AS SHOWN AND TO
CONSIST 110mm PVC WASTE WATER PIPING WITH SUITABLE GRADIENT OF FALL.
DETAIL UNDER INTERNAL WALLS 1:20
COLUMN FOOTING DETAIL 1:20
DATE: PROJECT: DRAWING: SCALE:
DRAWN BY:CLIENT:
PLOT: SIGNED:
FLOOR PLAN, SECTION A-A +
DETAILS
1:20 1:100
G H
PAGE #:
ADAM YOUNG / BAKWENA LODGE + CAMPING
BLCM-PSD-01
CLIENT ADDRESS:
NOV 2012
89/90 - RO, KAZANGULA
PAGE FORMAT: A3
DRAWING NUMBER:
/
MANAGERS HOUSE EXTENSION
+ ALTERATION FOR BAKWENA
LODGE
P.O.BOX 744
KASANE
SUBMITTED:
22000
11000 11000
173417341734 5202
596987650118165011811181 650650650650 987987
30010700
12230
30009230
5845331243870126398715009871263
300
540015801100
250
300
21542154215421542154
730870650750 150015002308707208701500 345465
12230
30009230
22501500
460
73020002750
230
3000
115
5655
230
230
2770
1463 10001375 870 990
22460
22460
22000
11000 2680
2285
3230
1150 545 2400 2590 1150 880
8320
747 987 747 987 747 987 650 1181 1287 2680
300208030027935527230381023031503235 115230
300
6556
6131
4353
3223
2450
284
340
900
623
900
10302320
2603
2450
776
EXIST. MAX
FRL1
FRB1
FFL1
NGL
CONC FLOOR
SLAB THICKENED
BELOW WALL
115 NON BEARING
BRICK WALL
COMPACTED
EARTH FILL
85
150
245
115
900
800
250
100
650
420
120150 150
CONC
FOOTING
COMPACTED
EARTH
BACKFILL
120 Ø STEEL
COLUMN
NGL
45.0°
4.9° 4.9°
2080
1848
1264
3925 23011531503235 115230
1040870
4. SOUTH ELEVATION 1:100
NORTH ELEVATION 1:100
EAST ELEVATION 1:100 WEST ELEVATION 1:100
DATE: PROJECT: DRAWING: SCALE:
DRAWN BY:CLIENT:
PLOT: SIGNED:
ELEVATIONS 1:100
G H
PAGE #:
ADAM YOUNG / BAKWENA LODGE + CAMPING
BLCM-ELEV-01
CLIENT ADDRESS:
NOV 2012
89/90 - RO, KAZANGULA
PAGE FORMAT: A3
DRAWING NUMBER:
/
MANAGERS HOUSE EXTENSION
+ ALTERATION FOR BAKWENA
LODGE
P.O.BOX 744
KASANE
SUBMITTED: