SlideShare a Scribd company logo
1 of 2
Download to read offline
Innovative technology
addressing power line
insulator string contamination
on T&D Networks
Innovative technology addressing power line
insulator string contamination that acts as a Partial
Discharge (PD) monitoring system for transmission
companies who wants to:
¤  Monitor their PD activity
¤  Improve the efficiency of their washing
operations while reducing costs
¤  Avoid power interruption due to vandalism
¤  Monitor the need for replacing composite
insulator based transmission lines
MetrySense-4000 unique added value:
utilities now have an overall vision of
contamination levels
Metrycom Communication Limited
6 Maskit Street Herzelia, 4673306, Israel
Tel: +972 9 779 2050 | Fax: +972 9 779 2065
Website: www.metrycom.com
Email: info@metrycom.com
Metrycom Communications Ltd. all right reserved, patent
pending, all specifications are subject to change without notice.
Unique visibility. Improved results.
Power quality is increasingly important to both power utilities and
industry regulators. This increased awareness is attributed to the
ongoing deregulation process, the aging electricity transmission
systems and increased environmental awareness. Consequently,
power utilities invest hundreds of millions of dollars in the
maintenance of their T&D infrastructures. Metrycom offers a
proven solution to utility companies who seek new technologies to
reduce costs, improve power quality, and enable enhanced grid
control.
Contamination of power line insulator strings is a major source of
power quality impairment, which often causes flashovers resulting
in shortcuts and wide-area power sags. The industry as a whole is
significantly impacted by quality impairment, causing enormous
yearly losses.
MS4000 monitoring and
transmission unit
The MS4000 is a wireless sensor solution for monitoring the
efficiency of T&D power lines. MS4000 employs unique partial
discharge sensors to detect contamination over power line insulator
stings. The system provides real-time information to maintenance
teams, helping them reduce operational costs and improve the
quality of the grid. Its wireless sensor units feature extremely low
power utilization, and can employ either power harvesting or a
primary battery (up to 20 years lifespan). Its highly reliable wireless
communications capabilities are based on frequency hopping and
IPv6 routing technologies.
Features
Unique Sensors: A single sensor covers 2km of power line.
Extremely Low power consumption
State-of-the-art IP wireless communication standards: supports
6LoWPAN (IPv6 over wireless – “the internet of things”).
Reliable Connectivity: for environments suffering radio interference/fading.
Long Range: point-to-point wireless connection (LOS) up to 5km, with
network coverage of up to hundreds of kilometers.
Flexible frequencies: 240MHz to 920MHz
IP Network IPv6 Communications over mesh radio network:
automatically create a wireless IP mesh radio network.
Supports large-scale mesh networks
Scalable and easy to deploy
Designed to operate in harsh conditions: temperature range of -40ºC to
85ºC, water and weather proof (IP67), resistant to electromagnetic
interferences and surges.
MS4000 sensor
Benefits
¤  Provides online grid visibility.
¤  Introduces real time high-voltage grid visibility of partial
discharges along the lines and in base sub-stations.
¤  Predicts flashovers
¤  Reduces interruptions and outages.
¤  Reduces maintenance costs by washing insulators at
the required segments of the power line and at the
optimal time.
¤  Provides feedback on the quality of insulator washing
operations.
¤  Provides infrastructure for additional sensor solutions
by including generic interfaces to many sensors types.
Metrycom enables a transition from
periodic to predictive maintenance
Currently, power utilities are spending hundreds of millions of
dollars every year in order to wash insulator strings, generally with
helicopters and trucks. The limitation that these methods impose
on maintenance crews is that they cannot get an overall view of the
contamination level in the power transmission and distribution
system. They are working blind and selecting the sections that
need to be washed mainly based on experience, not on fact. This is
proving extremely costly to the industry as a whole.
MetryView Server with MetrySense-4000 analytics module
MetryView server collects data from Sensors and DAQs via the
gateways and uses MetrySense-4000 analytics software module in
order to analyze and present the information.

More Related Content

What's hot

Quantum-safe data center interconnects
Quantum-safe data center interconnectsQuantum-safe data center interconnects
Quantum-safe data center interconnectsADVA
 
5G and Beyond: A Bristol Perspective
5G and Beyond: A Bristol Perspective5G and Beyond: A Bristol Perspective
5G and Beyond: A Bristol PerspectiveAndrew Nix
 
Techniques and Challenges in Designing Wideband Power Amplifiers Using GaN an...
Techniques and Challenges in Designing Wideband Power Amplifiers Using GaN an...Techniques and Challenges in Designing Wideband Power Amplifiers Using GaN an...
Techniques and Challenges in Designing Wideband Power Amplifiers Using GaN an...Lisa Bradley
 
Invitation to Saudi Power 2016
Invitation to Saudi Power 2016Invitation to Saudi Power 2016
Invitation to Saudi Power 2016Minka Grdesic
 
IRJET- - Control Center Viewing of UAS-based Real-Time Sensor and Video Measu...
IRJET- - Control Center Viewing of UAS-based Real-Time Sensor and Video Measu...IRJET- - Control Center Viewing of UAS-based Real-Time Sensor and Video Measu...
IRJET- - Control Center Viewing of UAS-based Real-Time Sensor and Video Measu...IRJET Journal
 
Bridge wave 4gwe-miami_02feb(3)
Bridge wave   4gwe-miami_02feb(3)Bridge wave   4gwe-miami_02feb(3)
Bridge wave 4gwe-miami_02feb(3)Carl Ford
 
Lifetime Power® Wireless Sensor System
Lifetime Power® Wireless Sensor SystemLifetime Power® Wireless Sensor System
Lifetime Power® Wireless Sensor SystemPowercast Sensors
 
Millimeter wave as the future of 5g
Millimeter wave as the future of 5g Millimeter wave as the future of 5g
Millimeter wave as the future of 5g Saurabh Verma
 
AN003 RF MEMS System Level Considerations for Optimized Battery Life
AN003 RF MEMS System Level Considerations for Optimized Battery LifeAN003 RF MEMS System Level Considerations for Optimized Battery Life
AN003 RF MEMS System Level Considerations for Optimized Battery LifeIgor Lalicevic
 
introduction to wimax
introduction to wimaxintroduction to wimax
introduction to wimaxKranthi Reddy
 
Xi3 wireless presentation ces 2015
Xi3 wireless presentation   ces 2015Xi3 wireless presentation   ces 2015
Xi3 wireless presentation ces 2015Henry Cooper
 
IRJET- Power Theft and Fault Detection using IoT Technology
IRJET-  	  Power Theft and Fault Detection using IoT TechnologyIRJET-  	  Power Theft and Fault Detection using IoT Technology
IRJET- Power Theft and Fault Detection using IoT TechnologyIRJET Journal
 
Stadium surveillance solution fiber only
Stadium surveillance solution fiber onlyStadium surveillance solution fiber only
Stadium surveillance solution fiber onlyHaitham Youssef
 
Arqiva the smart metering network leaflet
Arqiva   the smart metering network leafletArqiva   the smart metering network leaflet
Arqiva the smart metering network leafletAP Pietri
 

What's hot (19)

Wisp Scotia Wificity
Wisp Scotia WificityWisp Scotia Wificity
Wisp Scotia Wificity
 
Optelix_NanoWave_G1000_pr3 (1)
Optelix_NanoWave_G1000_pr3 (1)Optelix_NanoWave_G1000_pr3 (1)
Optelix_NanoWave_G1000_pr3 (1)
 
Quantum-safe data center interconnects
Quantum-safe data center interconnectsQuantum-safe data center interconnects
Quantum-safe data center interconnects
 
5G and Beyond: A Bristol Perspective
5G and Beyond: A Bristol Perspective5G and Beyond: A Bristol Perspective
5G and Beyond: A Bristol Perspective
 
Techniques and Challenges in Designing Wideband Power Amplifiers Using GaN an...
Techniques and Challenges in Designing Wideband Power Amplifiers Using GaN an...Techniques and Challenges in Designing Wideband Power Amplifiers Using GaN an...
Techniques and Challenges in Designing Wideband Power Amplifiers Using GaN an...
 
Invitation to Saudi Power 2016
Invitation to Saudi Power 2016Invitation to Saudi Power 2016
Invitation to Saudi Power 2016
 
IRJET- - Control Center Viewing of UAS-based Real-Time Sensor and Video Measu...
IRJET- - Control Center Viewing of UAS-based Real-Time Sensor and Video Measu...IRJET- - Control Center Viewing of UAS-based Real-Time Sensor and Video Measu...
IRJET- - Control Center Viewing of UAS-based Real-Time Sensor and Video Measu...
 
Assignment Of 5G Antenna Design Technique
Assignment Of 5G Antenna Design TechniqueAssignment Of 5G Antenna Design Technique
Assignment Of 5G Antenna Design Technique
 
B010220709
B010220709B010220709
B010220709
 
Bridge wave 4gwe-miami_02feb(3)
Bridge wave   4gwe-miami_02feb(3)Bridge wave   4gwe-miami_02feb(3)
Bridge wave 4gwe-miami_02feb(3)
 
5G for Internet of Things & Patents
5G for Internet of Things & Patents5G for Internet of Things & Patents
5G for Internet of Things & Patents
 
Lifetime Power® Wireless Sensor System
Lifetime Power® Wireless Sensor SystemLifetime Power® Wireless Sensor System
Lifetime Power® Wireless Sensor System
 
Millimeter wave as the future of 5g
Millimeter wave as the future of 5g Millimeter wave as the future of 5g
Millimeter wave as the future of 5g
 
AN003 RF MEMS System Level Considerations for Optimized Battery Life
AN003 RF MEMS System Level Considerations for Optimized Battery LifeAN003 RF MEMS System Level Considerations for Optimized Battery Life
AN003 RF MEMS System Level Considerations for Optimized Battery Life
 
introduction to wimax
introduction to wimaxintroduction to wimax
introduction to wimax
 
Xi3 wireless presentation ces 2015
Xi3 wireless presentation   ces 2015Xi3 wireless presentation   ces 2015
Xi3 wireless presentation ces 2015
 
IRJET- Power Theft and Fault Detection using IoT Technology
IRJET-  	  Power Theft and Fault Detection using IoT TechnologyIRJET-  	  Power Theft and Fault Detection using IoT Technology
IRJET- Power Theft and Fault Detection using IoT Technology
 
Stadium surveillance solution fiber only
Stadium surveillance solution fiber onlyStadium surveillance solution fiber only
Stadium surveillance solution fiber only
 
Arqiva the smart metering network leaflet
Arqiva   the smart metering network leafletArqiva   the smart metering network leaflet
Arqiva the smart metering network leaflet
 

Viewers also liked

Viewers also liked (12)

7863
78637863
7863
 
Tipos de navegadores
Tipos de navegadoresTipos de navegadores
Tipos de navegadores
 
2f372a3f-6ef8-4b1e-98e2-9a9b2eb3213e-160226133523
2f372a3f-6ef8-4b1e-98e2-9a9b2eb3213e-1602261335232f372a3f-6ef8-4b1e-98e2-9a9b2eb3213e-160226133523
2f372a3f-6ef8-4b1e-98e2-9a9b2eb3213e-160226133523
 
Panahar
PanaharPanahar
Panahar
 
حوارات الإنسان المعاصرلفضيلة الشيخ / فوزى محمد أبوزيد
 حوارات الإنسان المعاصرلفضيلة الشيخ / فوزى محمد أبوزيد  حوارات الإنسان المعاصرلفضيلة الشيخ / فوزى محمد أبوزيد
حوارات الإنسان المعاصرلفضيلة الشيخ / فوزى محمد أبوزيد
 
نسمات القرب
نسمات القربنسمات القرب
نسمات القرب
 
مقامات المقربين لفضيلة الشيخ / فوزى محمد أبوزيد
مقامات المقربين لفضيلة الشيخ / فوزى محمد أبوزيدمقامات المقربين لفضيلة الشيخ / فوزى محمد أبوزيد
مقامات المقربين لفضيلة الشيخ / فوزى محمد أبوزيد
 
TH 324 - Db3 overview of apologetics
TH 324 - Db3 overview of apologeticsTH 324 - Db3 overview of apologetics
TH 324 - Db3 overview of apologetics
 
Berklee College Of Music
Berklee College Of MusicBerklee College Of Music
Berklee College Of Music
 
Lifting Scheme Cores for Wavelet Transform
Lifting Scheme Cores for Wavelet TransformLifting Scheme Cores for Wavelet Transform
Lifting Scheme Cores for Wavelet Transform
 
منهاج الواصلين لفضيلة الشيخ / فوزى محمد أبوزيد
منهاج الواصلين لفضيلة الشيخ / فوزى محمد أبوزيدمنهاج الواصلين لفضيلة الشيخ / فوزى محمد أبوزيد
منهاج الواصلين لفضيلة الشيخ / فوزى محمد أبوزيد
 
Chapter 40
Chapter 40Chapter 40
Chapter 40
 

Similar to MS4000 Snapshot

Nokia_Sub-station_Automation_White_Paper_EN
Nokia_Sub-station_Automation_White_Paper_ENNokia_Sub-station_Automation_White_Paper_EN
Nokia_Sub-station_Automation_White_Paper_ENJuan Boggiano
 
Spectrum Requirements for Utilities
Spectrum Requirements for UtilitiesSpectrum Requirements for Utilities
Spectrum Requirements for UtilitiestechUK
 
Data transmission through power line
Data transmission through power lineData transmission through power line
Data transmission through power lineIAEME Publication
 
EasergyT300_Catalog_NRJED314621EN_022018.pdf
EasergyT300_Catalog_NRJED314621EN_022018.pdfEasergyT300_Catalog_NRJED314621EN_022018.pdf
EasergyT300_Catalog_NRJED314621EN_022018.pdfShantieHarunAlRosyid
 
Analysis of Fault Detection and its Location using Microcontroller for Underg...
Analysis of Fault Detection and its Location using Microcontroller for Underg...Analysis of Fault Detection and its Location using Microcontroller for Underg...
Analysis of Fault Detection and its Location using Microcontroller for Underg...IRJET Journal
 
SICAM FCM – Feeder Condition Monitor
SICAM FCM – Feeder Condition MonitorSICAM FCM – Feeder Condition Monitor
SICAM FCM – Feeder Condition Monitorashwini reliserv
 
SICAM FSI – Fault Sensor Indicator
SICAM FSI – Fault Sensor IndicatorSICAM FSI – Fault Sensor Indicator
SICAM FSI – Fault Sensor Indicatorashwini reliserv
 
IEC61850: Use of IEC61850 to telecontrol MV grids (Article)
IEC61850: Use of IEC61850 to telecontrol MV grids (Article)IEC61850: Use of IEC61850 to telecontrol MV grids (Article)
IEC61850: Use of IEC61850 to telecontrol MV grids (Article)iGrid T&D
 
AUTOMATIC ENERGY METER READING SYSTEM FOR BILLING PURPOSE
AUTOMATIC ENERGY METER READING SYSTEM FOR BILLING PURPOSEAUTOMATIC ENERGY METER READING SYSTEM FOR BILLING PURPOSE
AUTOMATIC ENERGY METER READING SYSTEM FOR BILLING PURPOSEBitan Das
 
Telecom Pole Sites Solutions
Telecom Pole Sites SolutionsTelecom Pole Sites Solutions
Telecom Pole Sites Solutionslokeshgupta80
 
TRANSFORMER HEALTH MONITORING SYSTEM
TRANSFORMER HEALTH MONITORING SYSTEMTRANSFORMER HEALTH MONITORING SYSTEM
TRANSFORMER HEALTH MONITORING SYSTEMIRJET Journal
 
Advancement in Smart grid by Embedding a Last meter in a Internet of Things P...
Advancement in Smart grid by Embedding a Last meter in a Internet of Things P...Advancement in Smart grid by Embedding a Last meter in a Internet of Things P...
Advancement in Smart grid by Embedding a Last meter in a Internet of Things P...IRJET Journal
 
Smart Grid - An Outline
Smart Grid - An OutlineSmart Grid - An Outline
Smart Grid - An OutlineShyam Penubolu
 
Wind Turbine programme
Wind Turbine programmeWind Turbine programme
Wind Turbine programmeMinka Grdesic
 
Omnik micro-inverter-m248-m500-kit
Omnik micro-inverter-m248-m500-kitOmnik micro-inverter-m248-m500-kit
Omnik micro-inverter-m248-m500-kitOmnik Solar
 

Similar to MS4000 Snapshot (20)

Flyer Metrycom PDF version - Final
Flyer Metrycom PDF version - FinalFlyer Metrycom PDF version - Final
Flyer Metrycom PDF version - Final
 
Nokia_Sub-station_Automation_White_Paper_EN
Nokia_Sub-station_Automation_White_Paper_ENNokia_Sub-station_Automation_White_Paper_EN
Nokia_Sub-station_Automation_White_Paper_EN
 
Spectrum Requirements for Utilities
Spectrum Requirements for UtilitiesSpectrum Requirements for Utilities
Spectrum Requirements for Utilities
 
Data transmission through power line
Data transmission through power lineData transmission through power line
Data transmission through power line
 
EasergyT300_Catalog_NRJED314621EN_022018.pdf
EasergyT300_Catalog_NRJED314621EN_022018.pdfEasergyT300_Catalog_NRJED314621EN_022018.pdf
EasergyT300_Catalog_NRJED314621EN_022018.pdf
 
MIDAS Folder
MIDAS FolderMIDAS Folder
MIDAS Folder
 
Analysis of Fault Detection and its Location using Microcontroller for Underg...
Analysis of Fault Detection and its Location using Microcontroller for Underg...Analysis of Fault Detection and its Location using Microcontroller for Underg...
Analysis of Fault Detection and its Location using Microcontroller for Underg...
 
SICAM FCM – Feeder Condition Monitor
SICAM FCM – Feeder Condition MonitorSICAM FCM – Feeder Condition Monitor
SICAM FCM – Feeder Condition Monitor
 
MS5000 Snapshot
MS5000 SnapshotMS5000 Snapshot
MS5000 Snapshot
 
SICAM FSI – Fault Sensor Indicator
SICAM FSI – Fault Sensor IndicatorSICAM FSI – Fault Sensor Indicator
SICAM FSI – Fault Sensor Indicator
 
IEC61850: Use of IEC61850 to telecontrol MV grids (Article)
IEC61850: Use of IEC61850 to telecontrol MV grids (Article)IEC61850: Use of IEC61850 to telecontrol MV grids (Article)
IEC61850: Use of IEC61850 to telecontrol MV grids (Article)
 
AUTOMATIC ENERGY METER READING SYSTEM FOR BILLING PURPOSE
AUTOMATIC ENERGY METER READING SYSTEM FOR BILLING PURPOSEAUTOMATIC ENERGY METER READING SYSTEM FOR BILLING PURPOSE
AUTOMATIC ENERGY METER READING SYSTEM FOR BILLING PURPOSE
 
Telecom Pole Sites Solutions
Telecom Pole Sites SolutionsTelecom Pole Sites Solutions
Telecom Pole Sites Solutions
 
TRANSFORMER HEALTH MONITORING SYSTEM
TRANSFORMER HEALTH MONITORING SYSTEMTRANSFORMER HEALTH MONITORING SYSTEM
TRANSFORMER HEALTH MONITORING SYSTEM
 
Advancement in Smart grid by Embedding a Last meter in a Internet of Things P...
Advancement in Smart grid by Embedding a Last meter in a Internet of Things P...Advancement in Smart grid by Embedding a Last meter in a Internet of Things P...
Advancement in Smart grid by Embedding a Last meter in a Internet of Things P...
 
Smart Grid - An Outline
Smart Grid - An OutlineSmart Grid - An Outline
Smart Grid - An Outline
 
Wind Turbine programme
Wind Turbine programmeWind Turbine programme
Wind Turbine programme
 
alm.pdf
alm.pdfalm.pdf
alm.pdf
 
alm.pdf
alm.pdfalm.pdf
alm.pdf
 
Omnik micro-inverter-m248-m500-kit
Omnik micro-inverter-m248-m500-kitOmnik micro-inverter-m248-m500-kit
Omnik micro-inverter-m248-m500-kit
 

More from Elliot Charles Willcox

More from Elliot Charles Willcox (8)

EM Newsletter EN Oct 2013
EM Newsletter EN Oct 2013EM Newsletter EN Oct 2013
EM Newsletter EN Oct 2013
 
Eurofin_Asset Managers (3)
Eurofin_Asset Managers (3)Eurofin_Asset Managers (3)
Eurofin_Asset Managers (3)
 
MS3000 Snapshot
MS3000 SnapshotMS3000 Snapshot
MS3000 Snapshot
 
Emerald FOF Flyer - v2.0
Emerald FOF Flyer - v2.0Emerald FOF Flyer - v2.0
Emerald FOF Flyer - v2.0
 
Marshall Bridge Flyer Flyer - v2.0
Marshall Bridge Flyer Flyer - v2.0Marshall Bridge Flyer Flyer - v2.0
Marshall Bridge Flyer Flyer - v2.0
 
Executive Snapshot - March 2014 - Generic Distribution
Executive Snapshot - March 2014 - Generic DistributionExecutive Snapshot - March 2014 - Generic Distribution
Executive Snapshot - March 2014 - Generic Distribution
 
SPHER NET full presentation - v1.1 Final
SPHER NET full presentation - v1.1 FinalSPHER NET full presentation - v1.1 Final
SPHER NET full presentation - v1.1 Final
 
SPHER OS Snapshot - v2.2
SPHER OS Snapshot - v2.2SPHER OS Snapshot - v2.2
SPHER OS Snapshot - v2.2
 

MS4000 Snapshot

  • 1. Innovative technology addressing power line insulator string contamination on T&D Networks Innovative technology addressing power line insulator string contamination that acts as a Partial Discharge (PD) monitoring system for transmission companies who wants to: ¤  Monitor their PD activity ¤  Improve the efficiency of their washing operations while reducing costs ¤  Avoid power interruption due to vandalism ¤  Monitor the need for replacing composite insulator based transmission lines
  • 2. MetrySense-4000 unique added value: utilities now have an overall vision of contamination levels Metrycom Communication Limited 6 Maskit Street Herzelia, 4673306, Israel Tel: +972 9 779 2050 | Fax: +972 9 779 2065 Website: www.metrycom.com Email: info@metrycom.com Metrycom Communications Ltd. all right reserved, patent pending, all specifications are subject to change without notice. Unique visibility. Improved results. Power quality is increasingly important to both power utilities and industry regulators. This increased awareness is attributed to the ongoing deregulation process, the aging electricity transmission systems and increased environmental awareness. Consequently, power utilities invest hundreds of millions of dollars in the maintenance of their T&D infrastructures. Metrycom offers a proven solution to utility companies who seek new technologies to reduce costs, improve power quality, and enable enhanced grid control. Contamination of power line insulator strings is a major source of power quality impairment, which often causes flashovers resulting in shortcuts and wide-area power sags. The industry as a whole is significantly impacted by quality impairment, causing enormous yearly losses. MS4000 monitoring and transmission unit The MS4000 is a wireless sensor solution for monitoring the efficiency of T&D power lines. MS4000 employs unique partial discharge sensors to detect contamination over power line insulator stings. The system provides real-time information to maintenance teams, helping them reduce operational costs and improve the quality of the grid. Its wireless sensor units feature extremely low power utilization, and can employ either power harvesting or a primary battery (up to 20 years lifespan). Its highly reliable wireless communications capabilities are based on frequency hopping and IPv6 routing technologies. Features Unique Sensors: A single sensor covers 2km of power line. Extremely Low power consumption State-of-the-art IP wireless communication standards: supports 6LoWPAN (IPv6 over wireless – “the internet of things”). Reliable Connectivity: for environments suffering radio interference/fading. Long Range: point-to-point wireless connection (LOS) up to 5km, with network coverage of up to hundreds of kilometers. Flexible frequencies: 240MHz to 920MHz IP Network IPv6 Communications over mesh radio network: automatically create a wireless IP mesh radio network. Supports large-scale mesh networks Scalable and easy to deploy Designed to operate in harsh conditions: temperature range of -40ºC to 85ºC, water and weather proof (IP67), resistant to electromagnetic interferences and surges. MS4000 sensor Benefits ¤  Provides online grid visibility. ¤  Introduces real time high-voltage grid visibility of partial discharges along the lines and in base sub-stations. ¤  Predicts flashovers ¤  Reduces interruptions and outages. ¤  Reduces maintenance costs by washing insulators at the required segments of the power line and at the optimal time. ¤  Provides feedback on the quality of insulator washing operations. ¤  Provides infrastructure for additional sensor solutions by including generic interfaces to many sensors types. Metrycom enables a transition from periodic to predictive maintenance Currently, power utilities are spending hundreds of millions of dollars every year in order to wash insulator strings, generally with helicopters and trucks. The limitation that these methods impose on maintenance crews is that they cannot get an overall view of the contamination level in the power transmission and distribution system. They are working blind and selecting the sections that need to be washed mainly based on experience, not on fact. This is proving extremely costly to the industry as a whole. MetryView Server with MetrySense-4000 analytics module MetryView server collects data from Sensors and DAQs via the gateways and uses MetrySense-4000 analytics software module in order to analyze and present the information.