SlideShare a Scribd company logo
1 of 33
CONNECTION DESIGN
โ€ข Connections must be designed at the strength limit state
โ€“ Average of the factored force effect at the connection and the force effect
in the member at the same point
โ€“ At least 75% of the force effect in the member
โ€ข End connections for diaphragms, cross-frames, lateral bracing for
straight flexural members - designed for factored member loads
โ€ข Connections should be symmetrical about member axis
โ€“ At least two bolts or equivalent weld per connection
โ€“ Members connected so that their gravity axes intersect at a point
โ€“ Eccentric connections should be avoided
โ€ข End connections for floorbeams and girders
โ€“ Two angles with thickness > 0.375 in.
โ€“ Made with high strength bolts
โ€“ If welded account for bending moment in design
BOLTED CONNECTIONS
โ€ข Slip-critical and bearing type bolted connections.
โ€ข Connections should be designed to be slip-critical where:
โ€“ stress reversal, heavy impact loads, severe vibration
โ€“ joint slippage would be detrimental to the serviceability of the structure
โ€ข Joints that must be designed to be slip-critical include
โ€“ Joints subject to fatigue loading or significant load reversal.
โ€“ Joints with oversized holes or slotted holes
โ€“ Joints where welds and bolts sharing in transmitting load
โ€“ Joints in axial tension or combined axial tension and shear
โ€ข Bearing-type bolted connections can be designed for joints
subjected to compression or joints for bracing members
SLIP-CRITICAL BOLTED CONNECTION
โ€ข Slip-critical bolted connections can fail in two ways: (a) slip at the
connection; (b) bearing failure of the connection
โ€ข Slip-critical connection must be designed to: (a) resist slip at load
Service II; and (b) resist bearing / shear at strength limit states
SLIP-CRITICAL BOLTED CONNECTION
โ€ข Slip-critical bolted connections can be installed with such a degree
of tightness ๏ƒ  large tensile forces in the bolt ๏ƒ  clamp the
connected plates together
โ€ข Applied Shear force resisted by friction
Tightened
P
P
Tightened
Tightened
P
P
P
P
Tb
N =Tb
N =Tb
N =Tb
P
F=mN
Tb
N = Tb
F=mN
N = Tb
N =Tb
P
Tb
N =Tb
Tb
N =Tb
N =Tb
N =Tb
P
F=mN
N =Tb
N =Tb
P
F=mN
Tb
N = Tb
Tb
N = Tb
F=mN
N = Tb
N =Tb
P
F=mN
N = Tb
N =Tb
N = Tb
N =Tb
P
SLIP-CRITICAL BOLTED CONNECTION
โ€ข Slip-critical connections can resist the shear force using friction.
โ€“ If the applied shear force is less than the friction that develops between
the two surfaces, then no slip will occur between them
โ€ข Nominal slip resistance of a bolt in a slip-critical connection
โ€“ Rn = Kh Ks Ns Pt
โ€“ Where, Pt = minimum required bolt tension specified in Table 1
Kh = hole factor specified in Table 1
Ks = surface condition factor specified in Table 3
SLIP-CRITICAL BOLTED CONNECTION
โ€ข Faying surfaces
โ€“ Unpainted clean mill scale, and blast-cleaned surfaces with Class A coating
โ€“ Unpainted blast-cleaned surfaces with Class B coating
โ€“ Hot-dip galvanized surfaces roughened by wire brushing โ€“ Class C
Bolt diameter
(in.)
Required Tension
(kips)
A325 A490
5/8 19 24
3/4 28 35
7/8 39 49
1 51 64
1-1/8 56 80
1-1/4 71 102
1-3/8 85 121
1-1/2 103 148
For standard holes 1.0
For oversize and short-slotted holes 0.85
For long slotted holes with the slot
Perpendicular to the force direction
0.70
For long-slotted holes with the slot
Parallel to the force direction
0.60
Values of Kh
Values of Pt
For Class A surface conditions 0.33
For Class B surface conditions 0.50
For Class C surface conditions 0.33
Values of Ks
SLIP-CRITICAL CONNECTION
โ€ข Connection subjected to tensile force (Tu), which reduces clamping
โ€“ Nominal slip resistance should be reduced by (1- Tu/Pt)
โ€ข Slip is not a catastrophic failure limit-state because slip-critical
bolted connections behave as bearing type connections after slip.
โ€ข Slip-critical bolted connections are further designed as bearing-type
bolted connection for the applicable factored strength limit state.
BEARING CONNECTION
โ€ข In a bearing-type connection, bolts are subjected to shear and the
connecting / connected plates are subjected to bearing stresses :
Bolt in shear
Bearing stresses in plate
Bearing stresses in plate
T
T
T
T
Bolt in shear
Bearing stresses in plate
Bearing stresses in plate
Bolt in shear
Bearing stresses in plate
Bearing stresses in plate
T
T
T
T
BEARING CONNECTION
โ€ข Bearing type connection can fail in several failure modes
a) Shear failure of the bolts
b) Excessive bearing deformation at the bolt holes in the connected parts
c) Edge tearing or fracture of the connected plate
d) Tearing or fracture of the connected plate between two bolt holes
e) Failure of member being connected due to fracture or block shear or ...
BEARING CONNECTION
โ€ข Nominal shear resistance of a bolt
โ€“ Threads excluded: Rn = 0.48 Ab Fub Ns
โ€“ Threads included: Rn = 0.38 Ab Fub Ns
Where, Ab = area of the bolt corresponding to the nominal diameter
Fub = 120 ksi for A325 bolts with diameters 0.5 through 1.0 in.
Fub = 105 ksi for A325 bolts with diameters 1.125 through 1.5 in.
Fub = 150 ksi for A490 bolts.
Ns = number of shear planes
โ€ข Resistance factor for bolts in shear = fs = 0.80
โ€ข Equations above - valid for joints with length < less than 50.0 in.
โ€“ If the length is greater than 50 in., then the values from the equations
have to be multiplied by 0.8
BEARING CONNECTION
โ€ข Effective bearing area of a bolt = the bolt diameter multiplied by the
thickness of the connected material on which it bears
โ€ข Bearing resistance for standard, oversize, or short-slotted holes in any
direction, and long-slotted holes parallel to the bearing force:
โ€“ For bolts spaced with clear distance between holes greater than or equal to 3.0 d
and for bolts with a clear end distance greater than or equal to 2.0 d
Rn = 2.4 d t Fu
โ€“ For bolts spaced with clear distance between holes less than 3.0 d
and for bolts with clear end distances less than 2.0 d
Rn = 1.2 Lc t Fu
Where, d = nominal bolt diameter
Lc= clear distance between holes or between the hole and the end of the member in
the direction of applied bearing force
Fu = tensile strength of the connected material
โ€ข The resistance factor fbb for material in bearing due to bolts = 0.80
BEARING CONNECTION
โ€ข SPACING REQUIREMENTS
โ€“ Minimum spacing between centers of bolts in standard holes shall not
be less than three times the diameter of the bolt
โ€“ For sealing against penetration of moisture in joints, the spacing on a
single line adjacent to the free edge shall satisfy s โ‰ค (4.0 + 4.0 t) โ‰ค 7.0
โ€“ Minimum edge distances
Bolt diameter
(in.)
Sheared
edge
Rolled or
Gas Cut edge
5/8 1-1/8 7/8
3/4 1-1/4 1
7/8 1-1/2 1-1/8
1 1-3/4 1-1/4
1-1/8 2 1-1/2
1-1/4 2-1/4 1-5/8
1-3/8 2-3/8 1-3/4
BOLTED CONNECTION
โ€ข Example 1 Design a slip-critical splice for a tension member. For
the Service II load combination, the member is subjected to a
tension load of 200 kips. For the strength limit state, the member is
subjected to a maximum tension load of 300 kips.
โ€“ The tension member is a W8 x 28 section made from M270-Gr. 50
steel. Use A325 bolts to design the slip-critical splice.
โ€ข Step I. Service and factored loads
โ€“ Service Load = 200 kips.
โ€“ Factored design load = 300 kips
โ€“ Tension member is W8 x 28 section made from M270 Gr.50. The
tension splice must be slip critical (i.e., it must not slip) at service loads.
BOLTED CONNECTION
Step II. Slip-critical splice connection
โ€ข Slip resistance of one fully-tensioned slip-critical bolt = Rn = Kh Ks Ns Pt
โ€“ f = 1.0 for slip-critical resistance evaluation
โ€“ Assume bolt diameter = d = ยพ in. Therefore Pt = 28 kips from Table 1
โ€“ Assume standard holes. Therefore Kh = 1.0
โ€“ Assume Class A surface condition. Therefore Ks = 0.33
โ€“ Therefore, fRn = 1.0 x 0.33 x 1 x 28 = 9.24 kips
โ€ข Therefore, number of ยพ in. diameter bolts required for splice to be slip-
critical at service loads = 200 / 9.24 = 21.64.
โ€ข Therefore, number of bolts required โ‰ฅ 22
BOLTED CONNECTION
Step III: Layout of flange-plate splice connection
โ€ข To be symmetric about centerline, need the number of bolts = multiple of 8.
โ€ข Therefore, choose 24 fully tensioned 3/4 in. A325 bolts with layout above.
โ€“ Slip-critical strength of the connection = 24 x 9.24 kips = 221.7 kips
โ€ข Minimum edge distance (Le) = 1 in. from Table 4.
โ€“ Design edge distance Le = 1.25 in.
โ€ข Minimum spacing = s = 3 x bolt diameter = 3 x ยพ = 2.25 in.
โ€“ Design spacing = 2.5 in.
BOLTED CONNECTION
Step IV: Connection strength at factored loads
โ€ข The connection should be designed as a normal shear/bearing
connection beyond this point for the factored load of 300 kips
โ€ข Shear strength of high strength bolt = f Rn = 0.80 x 0.38 x Ab x Fub Ns
โ€“ Equation given earlier for threads included in shear plane.
โ€“ Ab = 3.14 x 0.752 / 4 = 0.442 in2
โ€“ Fub = 120 ksi for A325 bolts with d < 1-1/8 in.
โ€“ Ns= 1
โ€“ Therefore, fRn = 16.1 kips
โ€ข The shear strength of 24 bolts = 16.1 kips/bolt x 24 = 386.9 kips
BOLTED CONNECTION
โ€ข Bearing strength of 3/4 in. bolts at edge holes (Le = 1.25 in.)
โ€“ fbb Rn = 0.80 x 1.2 Lc t Fu
Because the clear edge distance = 1.25 โ€“ (3/4 + 1/16)/2 = 0.84375 in. < 2 d
โ€“ fbb Rn = 0.80 x 1.2 x 0.84375 x 65 kips x t = 52.65 kips / in. thickness
โ€ข Bearing strength of of 3/4 in. bolts at non-edge holes (s = 2.5)
โ€“ fbb Rn = 0.80 x 2.4 d t Fu
Because the clear distance between holes = 2.5 โ€“ (3/4 + 1/16) = 1.6875 in. > 2d
โ€“ fbb Rn = 0.80 x 2.4 x 0.75 x 65 kips x t = 93.6 kips / in. thickness
โ€ข Bearing strength of bolt holes in flanges of wide flange section W8 x 28
(t = 0.465 in.)
โ€“ 8 x 52.65 x 0.465 +16 x 93.6 x 0.465 = 892 kips
CONNECTION STRENGTH
โ€ข Connection strength (fRn) > applied factored loads (gQ).
โ€“ Therefore ok
Connection Strength
Slip-critical strength = 221.7 kips
Shear strength of bolts = 386.9 kips
Bearing strength (plate) = 892 kips
WELDED CONNECTIONS
โ€ข Introduction
โ€“ The shielded metal arc welding (SMAW) process for field welding.
โ€“ Submerged metal arc welding (SAW) used for shop welding โ€“
automatic or semi-automatic process
โ€“ Quality control of welded connections is particularly difficult because of
defects below the surface, or even minor flaws at the surface, will
escape visual detection.
โ€“ Welders must be properly certified, and for critical work, special
inspection techniques such as radiography or ultrasonic testing must
be used.
WELDED CONNECTIONS
โ€ข Two most common types of welds are the fillet and the groove weld.
โ€“ lap joint โ€“ fillet welds placed in the corner formed by two plates
โ€“ Tee joint โ€“ fillet welds placed at the intersection of two plates.
โ€ข Groove welds โ€“ deposited in a gap or groove between two parts to be
connected e.g., butt, tee, and corner joints with beveled (prepared) edges
โ€“ Partial penetration groove welds can be made from one or both sides with or
without edge preparation.
Fillet weld
Fillet weld
Fillet weld
Fillet weld
Fillet weld
Fillet weld
WELDED CONNECTIONS
โ€ข Design of fillet welded connections
โ€“ Fillet welds are most common and used widely
โ€“ Weld sizes are specified in 1/16 in. increments
โ€“ Fillet welds are usually fail in shear, where the shear failure occurs
along a plane through the throat of the weld
โ€“ Shear stress in fillet weld of length L subjected to load P
fv =
a
a
Throat = a x cos45o
= 0.707 a
a
a
Throat = a x cos45o
= 0.707 a
Failure Plane
L
๏‚ท
w
L
a
707
.
0
P
FILLET WELDED CONNECTIONS
โ€ข The shear strength of the fillet weld = fe2 0.60 Fexx
โ€“ Where, fe2 = 0.80
โ€“ Fexx is the tensile strength of the weld electrode used in the welding
process. It can be 60, 70, 80, 90, 100, 110, or 120 ksi. The corresponding
electrodes are specified using the nomenclature E60XX, E70XX, E80XX,
and so on.
โ€ข Therefore, the shear strength of the fillet weld connection
โ€“ fRn = fe2 x 0.60 Fexx x 0.707 a Lw
โ€ข Electrode strength should match the base metal strength
โ€“ If yield stress (sy) of the base metal is ๏‚ฃ 60 - 65 ksi, use E70XX electrode
โ€“ If yield stress (sy) of the base metal is ๏‚ณ 60 - 65 ksi, use E80XX electrode
โ€ข E70XX is the most popular electrode used for SMAW fillet welds
โ€“ For E70XX, fRn = 0.80 x 0.60 x 70 x 0.707 a Lw = 0.2375 a Lw kips
FILLET WELDED CONNECTIONS
โ€ข The shear strength of the base metal must be considered:
โ€“ f Rn = fv x 0.58 Ag Fy
where, fv = 1.0
Fy is the yield strength of the base metal and Ag is the gross area in shear
Strength of weld in shear Strength of base metal
= 0.80 x 0.60 x Fexx x 0.707 x a x Lw = 1.0 x 0.58 x Fy x t x Lw
Smaller governs the strength of the weld
T
Elevation
Plan
T
Elevation
Plan
FILLET WELDED CONNECTIONS
Limitations on weld dimensions
โ€ข Minimum size (amin)
โ€“ Weld size need not exceed the thickness of the thinner part joined.
โ€“ amin depends on the thickness of the thicker part joined
โ€“ If the thickness of the thicker part joined (T) is less than or equal to ยพ in.
๏ƒ  amin = ยผ in.
โ€“ If T is greater than ยพ in. ๏ƒ  amin = 5/16 in.
โ€ข Maximum size (amax)
โ€“ Maximum size of fillet weld along edges of connected parts
โ€“ for material with thickness < 0.25 in., amax = thickness of the material
โ€“ for plates with thickness ๏‚ณ 0.25 in., amax = thickness of material - 1/16 in.
โ€ข Minimum length (Lw)
โ€“ Minimum effective length of fillet weld = 4 x size of fillet weld
โ€“ Effective length of fillet weld > 1.5 in.
FILLET WELDED CONNECTIONS
โ€ข Weld terminations and end returns
โ€“ End returns must not be provided around transverse stiffeners
โ€“ Fillet welds that resist tensile forces not parallel to the weld axis or
proportioned to withstand repeated stress shall not terminate at corners
of parts or members
โ€“ Where end returns can be made in the same plane, they shall be
returned continuously, full size around the corner, for a length equal to
twice the weld size (2a)
FILLET WELD DESIGN
Example 1 Design the fillet welded connection system for a double
angle tension member 2L 5 x 3ยฝ x 1/2 made from A36 steel to carry
a factored ultimate load of 250 kips.
Step I. Design the welded connection
Considering only the thickness of the angles; amin = 1/4 in.
Considering only the thickness of the angles; amax = 1/2 - 1/16 in. = 7/16 in.
Design, a = 3/8 in. = 0.375 in.
ยง Shear strength of weld metal = f Rn = 0.80 x 0.60 x FEXX x 0.707 x a x Lw
= 8.9 x Lw kips
Strength of the base metal in shear = f Rn = 1.0 x 0.58 x Fy x t x Lw
= 10.44 Lw kips
ยง Shear strength of weld metal governs, f Rn = 8.9 Lw kips
FILLET WELD DESIGN
โ€ข Design strength f Rn > 250 kips
โ€“ Therefore, 8.9 Lw > 250 kips
โ€“ Therefore, Lw > 28.1 in.
โ€ข Design length of 3/8 in. E70XX fillet weld = 30.0 in.
โ€ข Shear strength of fillet weld = 267 kips
โ€ข Connection layout
โ€“ Connection must be designed to minimize eccentricity of loading.
Therefore, the center or gravity of the welded connection must coincide
with the center of gravity of the member.
(d)
Tu
f L2
f L1
L1
L2
3.4 in.
(d)
Tu
f L2
f L1
L1
L2
3.4 in.
FILLET WELD DESIGN
โ€ข Connection layout
โ€“ Connection must be designed to minimize eccentricity of loading.
โ€“ The c.g. of the welded connection must coincide with c.g. of the member
โ€“ Total length of weld required = 30 in.
โ€“ Two angles ๏ƒ assume each angle will have weld length of 15 in.
(d)
Tu
f L2
f L1
L1
L2
3.4 in.
(d)
Tu
f L2
f L1
L1
L2
3.4 in.
FILLET WELD DESIGN
โ€ข The tension force Tu acts along the c.g. of the member, which is
1.65 in. from the top and 3.35 in. from the bottom (AISC manual).
โ€“ Let, f be the strength of the fillet weld per unit length.
Therefore, fL1 + fL2 = Tu
And fL2 x 3.35 - fL1 x 1.65 = 0 - taking moments about the member c.g.
โ€“ Therefore, L1 = 2.0 L2
But, L1 + L2 = 15.0 in.
โ€“ Therefore, L1 = 10 in. and L2 = 5 in.
Design: L1 = 10.0 in. and L2 = 5.0 in.
FILLET WELD DESIGN
โ€ข Consider another layout
(e)
Tu
f L2
L1
L2
f L1
5f 3.4 in.
(e)
Tu
f L2
L1
L2
f L1
5f 3.4 in.
fL1 + fL2 + 5f = Tu
fL2 x 3.5 + 5f x 0.85 - fL1 x 1.65 = 0 - Moment about member c.g.
Additionally, L1 + L2 + 5 = 15.0 in.
Therefore, L1 = 7.6 in. and L2 = 2.4 in.
Design: L1 = 8.0 in. and L2 = 3.0 in.
Groove Welded Connections
โ€ข Connects structural members that are aligned in the same plane
โ€ข Basic Types:
โ€“ Complete joint penetration groove weld: transmits full load of the member they join
and have the same strength as the base metal.
โ€“ Partial penetration groove weld: Welds do not extend completely through the
thickness of the pieces being joined.
Groove Welds
Complete penetration groove welded connections
โ€ข Tension and compression loaded
โ€“ Factored resistance = factored resistance of base metal
โ€ข Shear loaded on effective area ๏ƒ  lesser of
โ€“ Factored resistance of weld = 0.6 x fe1 x Fexx = 0.6 x 0.85 x Fexx
โ€“ 60% of factored resistance of base metal in tension
Partial penetration groove-welded connections
โ€ข Tension or compression parallel to the weld axis and compression normal
to effective area ๏ƒ  factored resistance of the base metal
โ€ข Tension normal to the effective area ๏ƒ  lesser of
โ€“ Factored resistance of the weld = 0.6 fe2 Fexx = 0.60 x 0.80 x Fexx
โ€“ Factored resistance of the base metal
โ€ข Shear loaded ๏ƒ  lesser of
โ€“ Factored resistance of the weld = 0.6 fe2 Fexx = 0.60 x 0.80 x Fexx
โ€“ Factored resistance of base metal = 0.58 Fy
Groove Welds

More Related Content

Similar to Connection_Design.ppt

Similar to Connection_Design.ppt (20)

chapter 4 flexural design of beam 2021.pdf
chapter 4 flexural design of beam 2021.pdfchapter 4 flexural design of beam 2021.pdf
chapter 4 flexural design of beam 2021.pdf
ย 
Machine Design and Industrial Drafting.pptx
Machine Design and Industrial Drafting.pptxMachine Design and Industrial Drafting.pptx
Machine Design and Industrial Drafting.pptx
ย 
Tension members
Tension membersTension members
Tension members
ย 
Welding Distortion Control.ppt
Welding Distortion Control.pptWelding Distortion Control.ppt
Welding Distortion Control.ppt
ย 
Koppolu abishek prying action
Koppolu abishek   prying actionKoppolu abishek   prying action
Koppolu abishek prying action
ย 
Unit 3 Temporary and Permanent Joints.pptx
Unit 3 Temporary and Permanent Joints.pptxUnit 3 Temporary and Permanent Joints.pptx
Unit 3 Temporary and Permanent Joints.pptx
ย 
Bolts
BoltsBolts
Bolts
ย 
Design of Structures Chapter2.pdf
Design of Structures Chapter2.pdfDesign of Structures Chapter2.pdf
Design of Structures Chapter2.pdf
ย 
Design of Structures Chapter2.pptx
Design of Structures Chapter2.pptxDesign of Structures Chapter2.pptx
Design of Structures Chapter2.pptx
ย 
Lec12 Continuous Beams and One Way Slabs(2) Columns (Reinforced Concrete Desi...
Lec12 Continuous Beams and One Way Slabs(2) Columns (Reinforced Concrete Desi...Lec12 Continuous Beams and One Way Slabs(2) Columns (Reinforced Concrete Desi...
Lec12 Continuous Beams and One Way Slabs(2) Columns (Reinforced Concrete Desi...
ย 
Chap5
Chap5Chap5
Chap5
ย 
Bolted connections
Bolted connectionsBolted connections
Bolted connections
ย 
07-Strength of Bolted Connections (Steel Structural Design & Prof. Shehab Mou...
07-Strength of Bolted Connections (Steel Structural Design & Prof. Shehab Mou...07-Strength of Bolted Connections (Steel Structural Design & Prof. Shehab Mou...
07-Strength of Bolted Connections (Steel Structural Design & Prof. Shehab Mou...
ย 
RCC column_Shortly Axially Loaded column.pptx
RCC column_Shortly Axially Loaded column.pptxRCC column_Shortly Axially Loaded column.pptx
RCC column_Shortly Axially Loaded column.pptx
ย 
Design and Detailing of RC Deep beams as per IS 456-2000
Design and Detailing of RC Deep beams as per IS 456-2000Design and Detailing of RC Deep beams as per IS 456-2000
Design and Detailing of RC Deep beams as per IS 456-2000
ย 
Welded
WeldedWelded
Welded
ย 
Ductile detailing
Ductile detailingDuctile detailing
Ductile detailing
ย 
Design of torsion reinforcement
 Design of torsion reinforcement Design of torsion reinforcement
Design of torsion reinforcement
ย 
Lecture 7 bolted connections-students.pdf
Lecture 7 bolted connections-students.pdfLecture 7 bolted connections-students.pdf
Lecture 7 bolted connections-students.pdf
ย 
Reinforced Cement Concrete and Bar Bending Schedule
Reinforced Cement Concrete and Bar Bending ScheduleReinforced Cement Concrete and Bar Bending Schedule
Reinforced Cement Concrete and Bar Bending Schedule
ย 

Recently uploaded

VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
SUHANI PANDEY
ย 
Call Girls in Ramesh Nagar Delhi ๐Ÿ’ฏ Call Us ๐Ÿ”9953056974 ๐Ÿ” Escort Service
Call Girls in Ramesh Nagar Delhi ๐Ÿ’ฏ Call Us ๐Ÿ”9953056974 ๐Ÿ” Escort ServiceCall Girls in Ramesh Nagar Delhi ๐Ÿ’ฏ Call Us ๐Ÿ”9953056974 ๐Ÿ” Escort Service
Call Girls in Ramesh Nagar Delhi ๐Ÿ’ฏ Call Us ๐Ÿ”9953056974 ๐Ÿ” Escort Service
9953056974 Low Rate Call Girls In Saket, Delhi NCR
ย 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
dollysharma2066
ย 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power Play
Epec Engineered Technologies
ย 
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
dharasingh5698
ย 

Recently uploaded (20)

Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPT
ย 
22-prompt engineering noted slide shown.pdf
22-prompt engineering noted slide shown.pdf22-prompt engineering noted slide shown.pdf
22-prompt engineering noted slide shown.pdf
ย 
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
ย 
Call Girls in Ramesh Nagar Delhi ๐Ÿ’ฏ Call Us ๐Ÿ”9953056974 ๐Ÿ” Escort Service
Call Girls in Ramesh Nagar Delhi ๐Ÿ’ฏ Call Us ๐Ÿ”9953056974 ๐Ÿ” Escort ServiceCall Girls in Ramesh Nagar Delhi ๐Ÿ’ฏ Call Us ๐Ÿ”9953056974 ๐Ÿ” Escort Service
Call Girls in Ramesh Nagar Delhi ๐Ÿ’ฏ Call Us ๐Ÿ”9953056974 ๐Ÿ” Escort Service
ย 
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
COST-EFFETIVE  and Energy Efficient BUILDINGS ptxCOST-EFFETIVE  and Energy Efficient BUILDINGS ptx
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
ย 
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
ย 
Double Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torqueDouble Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torque
ย 
Design For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the startDesign For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the start
ย 
Thermal Engineering Unit - I & II . ppt
Thermal Engineering  Unit - I & II . pptThermal Engineering  Unit - I & II . ppt
Thermal Engineering Unit - I & II . ppt
ย 
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
ย 
Minimum and Maximum Modes of microprocessor 8086
Minimum and Maximum Modes of microprocessor 8086Minimum and Maximum Modes of microprocessor 8086
Minimum and Maximum Modes of microprocessor 8086
ย 
Unit 2- Effective stress & Permeability.pdf
Unit 2- Effective stress & Permeability.pdfUnit 2- Effective stress & Permeability.pdf
Unit 2- Effective stress & Permeability.pdf
ย 
A Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna MunicipalityA Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna Municipality
ย 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
ย 
Hazard Identification (HAZID) vs. Hazard and Operability (HAZOP): A Comparati...
Hazard Identification (HAZID) vs. Hazard and Operability (HAZOP): A Comparati...Hazard Identification (HAZID) vs. Hazard and Operability (HAZOP): A Comparati...
Hazard Identification (HAZID) vs. Hazard and Operability (HAZOP): A Comparati...
ย 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power Play
ย 
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
ย 
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
ย 
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced LoadsFEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
ย 
chapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringchapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineering
ย 

Connection_Design.ppt

  • 1. CONNECTION DESIGN โ€ข Connections must be designed at the strength limit state โ€“ Average of the factored force effect at the connection and the force effect in the member at the same point โ€“ At least 75% of the force effect in the member โ€ข End connections for diaphragms, cross-frames, lateral bracing for straight flexural members - designed for factored member loads โ€ข Connections should be symmetrical about member axis โ€“ At least two bolts or equivalent weld per connection โ€“ Members connected so that their gravity axes intersect at a point โ€“ Eccentric connections should be avoided โ€ข End connections for floorbeams and girders โ€“ Two angles with thickness > 0.375 in. โ€“ Made with high strength bolts โ€“ If welded account for bending moment in design
  • 2. BOLTED CONNECTIONS โ€ข Slip-critical and bearing type bolted connections. โ€ข Connections should be designed to be slip-critical where: โ€“ stress reversal, heavy impact loads, severe vibration โ€“ joint slippage would be detrimental to the serviceability of the structure โ€ข Joints that must be designed to be slip-critical include โ€“ Joints subject to fatigue loading or significant load reversal. โ€“ Joints with oversized holes or slotted holes โ€“ Joints where welds and bolts sharing in transmitting load โ€“ Joints in axial tension or combined axial tension and shear โ€ข Bearing-type bolted connections can be designed for joints subjected to compression or joints for bracing members
  • 3. SLIP-CRITICAL BOLTED CONNECTION โ€ข Slip-critical bolted connections can fail in two ways: (a) slip at the connection; (b) bearing failure of the connection โ€ข Slip-critical connection must be designed to: (a) resist slip at load Service II; and (b) resist bearing / shear at strength limit states
  • 4. SLIP-CRITICAL BOLTED CONNECTION โ€ข Slip-critical bolted connections can be installed with such a degree of tightness ๏ƒ  large tensile forces in the bolt ๏ƒ  clamp the connected plates together โ€ข Applied Shear force resisted by friction Tightened P P Tightened Tightened P P P P Tb N =Tb N =Tb N =Tb P F=mN Tb N = Tb F=mN N = Tb N =Tb P Tb N =Tb Tb N =Tb N =Tb N =Tb P F=mN N =Tb N =Tb P F=mN Tb N = Tb Tb N = Tb F=mN N = Tb N =Tb P F=mN N = Tb N =Tb N = Tb N =Tb P
  • 5. SLIP-CRITICAL BOLTED CONNECTION โ€ข Slip-critical connections can resist the shear force using friction. โ€“ If the applied shear force is less than the friction that develops between the two surfaces, then no slip will occur between them โ€ข Nominal slip resistance of a bolt in a slip-critical connection โ€“ Rn = Kh Ks Ns Pt โ€“ Where, Pt = minimum required bolt tension specified in Table 1 Kh = hole factor specified in Table 1 Ks = surface condition factor specified in Table 3
  • 6. SLIP-CRITICAL BOLTED CONNECTION โ€ข Faying surfaces โ€“ Unpainted clean mill scale, and blast-cleaned surfaces with Class A coating โ€“ Unpainted blast-cleaned surfaces with Class B coating โ€“ Hot-dip galvanized surfaces roughened by wire brushing โ€“ Class C Bolt diameter (in.) Required Tension (kips) A325 A490 5/8 19 24 3/4 28 35 7/8 39 49 1 51 64 1-1/8 56 80 1-1/4 71 102 1-3/8 85 121 1-1/2 103 148 For standard holes 1.0 For oversize and short-slotted holes 0.85 For long slotted holes with the slot Perpendicular to the force direction 0.70 For long-slotted holes with the slot Parallel to the force direction 0.60 Values of Kh Values of Pt For Class A surface conditions 0.33 For Class B surface conditions 0.50 For Class C surface conditions 0.33 Values of Ks
  • 7. SLIP-CRITICAL CONNECTION โ€ข Connection subjected to tensile force (Tu), which reduces clamping โ€“ Nominal slip resistance should be reduced by (1- Tu/Pt) โ€ข Slip is not a catastrophic failure limit-state because slip-critical bolted connections behave as bearing type connections after slip. โ€ข Slip-critical bolted connections are further designed as bearing-type bolted connection for the applicable factored strength limit state.
  • 8. BEARING CONNECTION โ€ข In a bearing-type connection, bolts are subjected to shear and the connecting / connected plates are subjected to bearing stresses : Bolt in shear Bearing stresses in plate Bearing stresses in plate T T T T Bolt in shear Bearing stresses in plate Bearing stresses in plate Bolt in shear Bearing stresses in plate Bearing stresses in plate T T T T
  • 9. BEARING CONNECTION โ€ข Bearing type connection can fail in several failure modes a) Shear failure of the bolts b) Excessive bearing deformation at the bolt holes in the connected parts c) Edge tearing or fracture of the connected plate d) Tearing or fracture of the connected plate between two bolt holes e) Failure of member being connected due to fracture or block shear or ...
  • 10. BEARING CONNECTION โ€ข Nominal shear resistance of a bolt โ€“ Threads excluded: Rn = 0.48 Ab Fub Ns โ€“ Threads included: Rn = 0.38 Ab Fub Ns Where, Ab = area of the bolt corresponding to the nominal diameter Fub = 120 ksi for A325 bolts with diameters 0.5 through 1.0 in. Fub = 105 ksi for A325 bolts with diameters 1.125 through 1.5 in. Fub = 150 ksi for A490 bolts. Ns = number of shear planes โ€ข Resistance factor for bolts in shear = fs = 0.80 โ€ข Equations above - valid for joints with length < less than 50.0 in. โ€“ If the length is greater than 50 in., then the values from the equations have to be multiplied by 0.8
  • 11. BEARING CONNECTION โ€ข Effective bearing area of a bolt = the bolt diameter multiplied by the thickness of the connected material on which it bears โ€ข Bearing resistance for standard, oversize, or short-slotted holes in any direction, and long-slotted holes parallel to the bearing force: โ€“ For bolts spaced with clear distance between holes greater than or equal to 3.0 d and for bolts with a clear end distance greater than or equal to 2.0 d Rn = 2.4 d t Fu โ€“ For bolts spaced with clear distance between holes less than 3.0 d and for bolts with clear end distances less than 2.0 d Rn = 1.2 Lc t Fu Where, d = nominal bolt diameter Lc= clear distance between holes or between the hole and the end of the member in the direction of applied bearing force Fu = tensile strength of the connected material โ€ข The resistance factor fbb for material in bearing due to bolts = 0.80
  • 12. BEARING CONNECTION โ€ข SPACING REQUIREMENTS โ€“ Minimum spacing between centers of bolts in standard holes shall not be less than three times the diameter of the bolt โ€“ For sealing against penetration of moisture in joints, the spacing on a single line adjacent to the free edge shall satisfy s โ‰ค (4.0 + 4.0 t) โ‰ค 7.0 โ€“ Minimum edge distances Bolt diameter (in.) Sheared edge Rolled or Gas Cut edge 5/8 1-1/8 7/8 3/4 1-1/4 1 7/8 1-1/2 1-1/8 1 1-3/4 1-1/4 1-1/8 2 1-1/2 1-1/4 2-1/4 1-5/8 1-3/8 2-3/8 1-3/4
  • 13. BOLTED CONNECTION โ€ข Example 1 Design a slip-critical splice for a tension member. For the Service II load combination, the member is subjected to a tension load of 200 kips. For the strength limit state, the member is subjected to a maximum tension load of 300 kips. โ€“ The tension member is a W8 x 28 section made from M270-Gr. 50 steel. Use A325 bolts to design the slip-critical splice. โ€ข Step I. Service and factored loads โ€“ Service Load = 200 kips. โ€“ Factored design load = 300 kips โ€“ Tension member is W8 x 28 section made from M270 Gr.50. The tension splice must be slip critical (i.e., it must not slip) at service loads.
  • 14. BOLTED CONNECTION Step II. Slip-critical splice connection โ€ข Slip resistance of one fully-tensioned slip-critical bolt = Rn = Kh Ks Ns Pt โ€“ f = 1.0 for slip-critical resistance evaluation โ€“ Assume bolt diameter = d = ยพ in. Therefore Pt = 28 kips from Table 1 โ€“ Assume standard holes. Therefore Kh = 1.0 โ€“ Assume Class A surface condition. Therefore Ks = 0.33 โ€“ Therefore, fRn = 1.0 x 0.33 x 1 x 28 = 9.24 kips โ€ข Therefore, number of ยพ in. diameter bolts required for splice to be slip- critical at service loads = 200 / 9.24 = 21.64. โ€ข Therefore, number of bolts required โ‰ฅ 22
  • 15. BOLTED CONNECTION Step III: Layout of flange-plate splice connection โ€ข To be symmetric about centerline, need the number of bolts = multiple of 8. โ€ข Therefore, choose 24 fully tensioned 3/4 in. A325 bolts with layout above. โ€“ Slip-critical strength of the connection = 24 x 9.24 kips = 221.7 kips โ€ข Minimum edge distance (Le) = 1 in. from Table 4. โ€“ Design edge distance Le = 1.25 in. โ€ข Minimum spacing = s = 3 x bolt diameter = 3 x ยพ = 2.25 in. โ€“ Design spacing = 2.5 in.
  • 16. BOLTED CONNECTION Step IV: Connection strength at factored loads โ€ข The connection should be designed as a normal shear/bearing connection beyond this point for the factored load of 300 kips โ€ข Shear strength of high strength bolt = f Rn = 0.80 x 0.38 x Ab x Fub Ns โ€“ Equation given earlier for threads included in shear plane. โ€“ Ab = 3.14 x 0.752 / 4 = 0.442 in2 โ€“ Fub = 120 ksi for A325 bolts with d < 1-1/8 in. โ€“ Ns= 1 โ€“ Therefore, fRn = 16.1 kips โ€ข The shear strength of 24 bolts = 16.1 kips/bolt x 24 = 386.9 kips
  • 17. BOLTED CONNECTION โ€ข Bearing strength of 3/4 in. bolts at edge holes (Le = 1.25 in.) โ€“ fbb Rn = 0.80 x 1.2 Lc t Fu Because the clear edge distance = 1.25 โ€“ (3/4 + 1/16)/2 = 0.84375 in. < 2 d โ€“ fbb Rn = 0.80 x 1.2 x 0.84375 x 65 kips x t = 52.65 kips / in. thickness โ€ข Bearing strength of of 3/4 in. bolts at non-edge holes (s = 2.5) โ€“ fbb Rn = 0.80 x 2.4 d t Fu Because the clear distance between holes = 2.5 โ€“ (3/4 + 1/16) = 1.6875 in. > 2d โ€“ fbb Rn = 0.80 x 2.4 x 0.75 x 65 kips x t = 93.6 kips / in. thickness โ€ข Bearing strength of bolt holes in flanges of wide flange section W8 x 28 (t = 0.465 in.) โ€“ 8 x 52.65 x 0.465 +16 x 93.6 x 0.465 = 892 kips
  • 18. CONNECTION STRENGTH โ€ข Connection strength (fRn) > applied factored loads (gQ). โ€“ Therefore ok Connection Strength Slip-critical strength = 221.7 kips Shear strength of bolts = 386.9 kips Bearing strength (plate) = 892 kips
  • 19. WELDED CONNECTIONS โ€ข Introduction โ€“ The shielded metal arc welding (SMAW) process for field welding. โ€“ Submerged metal arc welding (SAW) used for shop welding โ€“ automatic or semi-automatic process โ€“ Quality control of welded connections is particularly difficult because of defects below the surface, or even minor flaws at the surface, will escape visual detection. โ€“ Welders must be properly certified, and for critical work, special inspection techniques such as radiography or ultrasonic testing must be used.
  • 20. WELDED CONNECTIONS โ€ข Two most common types of welds are the fillet and the groove weld. โ€“ lap joint โ€“ fillet welds placed in the corner formed by two plates โ€“ Tee joint โ€“ fillet welds placed at the intersection of two plates. โ€ข Groove welds โ€“ deposited in a gap or groove between two parts to be connected e.g., butt, tee, and corner joints with beveled (prepared) edges โ€“ Partial penetration groove welds can be made from one or both sides with or without edge preparation. Fillet weld Fillet weld Fillet weld Fillet weld Fillet weld Fillet weld
  • 21. WELDED CONNECTIONS โ€ข Design of fillet welded connections โ€“ Fillet welds are most common and used widely โ€“ Weld sizes are specified in 1/16 in. increments โ€“ Fillet welds are usually fail in shear, where the shear failure occurs along a plane through the throat of the weld โ€“ Shear stress in fillet weld of length L subjected to load P fv = a a Throat = a x cos45o = 0.707 a a a Throat = a x cos45o = 0.707 a Failure Plane L ๏‚ท w L a 707 . 0 P
  • 22. FILLET WELDED CONNECTIONS โ€ข The shear strength of the fillet weld = fe2 0.60 Fexx โ€“ Where, fe2 = 0.80 โ€“ Fexx is the tensile strength of the weld electrode used in the welding process. It can be 60, 70, 80, 90, 100, 110, or 120 ksi. The corresponding electrodes are specified using the nomenclature E60XX, E70XX, E80XX, and so on. โ€ข Therefore, the shear strength of the fillet weld connection โ€“ fRn = fe2 x 0.60 Fexx x 0.707 a Lw โ€ข Electrode strength should match the base metal strength โ€“ If yield stress (sy) of the base metal is ๏‚ฃ 60 - 65 ksi, use E70XX electrode โ€“ If yield stress (sy) of the base metal is ๏‚ณ 60 - 65 ksi, use E80XX electrode โ€ข E70XX is the most popular electrode used for SMAW fillet welds โ€“ For E70XX, fRn = 0.80 x 0.60 x 70 x 0.707 a Lw = 0.2375 a Lw kips
  • 23. FILLET WELDED CONNECTIONS โ€ข The shear strength of the base metal must be considered: โ€“ f Rn = fv x 0.58 Ag Fy where, fv = 1.0 Fy is the yield strength of the base metal and Ag is the gross area in shear Strength of weld in shear Strength of base metal = 0.80 x 0.60 x Fexx x 0.707 x a x Lw = 1.0 x 0.58 x Fy x t x Lw Smaller governs the strength of the weld T Elevation Plan T Elevation Plan
  • 24. FILLET WELDED CONNECTIONS Limitations on weld dimensions โ€ข Minimum size (amin) โ€“ Weld size need not exceed the thickness of the thinner part joined. โ€“ amin depends on the thickness of the thicker part joined โ€“ If the thickness of the thicker part joined (T) is less than or equal to ยพ in. ๏ƒ  amin = ยผ in. โ€“ If T is greater than ยพ in. ๏ƒ  amin = 5/16 in. โ€ข Maximum size (amax) โ€“ Maximum size of fillet weld along edges of connected parts โ€“ for material with thickness < 0.25 in., amax = thickness of the material โ€“ for plates with thickness ๏‚ณ 0.25 in., amax = thickness of material - 1/16 in. โ€ข Minimum length (Lw) โ€“ Minimum effective length of fillet weld = 4 x size of fillet weld โ€“ Effective length of fillet weld > 1.5 in.
  • 25. FILLET WELDED CONNECTIONS โ€ข Weld terminations and end returns โ€“ End returns must not be provided around transverse stiffeners โ€“ Fillet welds that resist tensile forces not parallel to the weld axis or proportioned to withstand repeated stress shall not terminate at corners of parts or members โ€“ Where end returns can be made in the same plane, they shall be returned continuously, full size around the corner, for a length equal to twice the weld size (2a)
  • 26. FILLET WELD DESIGN Example 1 Design the fillet welded connection system for a double angle tension member 2L 5 x 3ยฝ x 1/2 made from A36 steel to carry a factored ultimate load of 250 kips. Step I. Design the welded connection Considering only the thickness of the angles; amin = 1/4 in. Considering only the thickness of the angles; amax = 1/2 - 1/16 in. = 7/16 in. Design, a = 3/8 in. = 0.375 in. ยง Shear strength of weld metal = f Rn = 0.80 x 0.60 x FEXX x 0.707 x a x Lw = 8.9 x Lw kips Strength of the base metal in shear = f Rn = 1.0 x 0.58 x Fy x t x Lw = 10.44 Lw kips ยง Shear strength of weld metal governs, f Rn = 8.9 Lw kips
  • 27. FILLET WELD DESIGN โ€ข Design strength f Rn > 250 kips โ€“ Therefore, 8.9 Lw > 250 kips โ€“ Therefore, Lw > 28.1 in. โ€ข Design length of 3/8 in. E70XX fillet weld = 30.0 in. โ€ข Shear strength of fillet weld = 267 kips โ€ข Connection layout โ€“ Connection must be designed to minimize eccentricity of loading. Therefore, the center or gravity of the welded connection must coincide with the center of gravity of the member. (d) Tu f L2 f L1 L1 L2 3.4 in. (d) Tu f L2 f L1 L1 L2 3.4 in.
  • 28. FILLET WELD DESIGN โ€ข Connection layout โ€“ Connection must be designed to minimize eccentricity of loading. โ€“ The c.g. of the welded connection must coincide with c.g. of the member โ€“ Total length of weld required = 30 in. โ€“ Two angles ๏ƒ assume each angle will have weld length of 15 in. (d) Tu f L2 f L1 L1 L2 3.4 in. (d) Tu f L2 f L1 L1 L2 3.4 in.
  • 29. FILLET WELD DESIGN โ€ข The tension force Tu acts along the c.g. of the member, which is 1.65 in. from the top and 3.35 in. from the bottom (AISC manual). โ€“ Let, f be the strength of the fillet weld per unit length. Therefore, fL1 + fL2 = Tu And fL2 x 3.35 - fL1 x 1.65 = 0 - taking moments about the member c.g. โ€“ Therefore, L1 = 2.0 L2 But, L1 + L2 = 15.0 in. โ€“ Therefore, L1 = 10 in. and L2 = 5 in. Design: L1 = 10.0 in. and L2 = 5.0 in.
  • 30. FILLET WELD DESIGN โ€ข Consider another layout (e) Tu f L2 L1 L2 f L1 5f 3.4 in. (e) Tu f L2 L1 L2 f L1 5f 3.4 in. fL1 + fL2 + 5f = Tu fL2 x 3.5 + 5f x 0.85 - fL1 x 1.65 = 0 - Moment about member c.g. Additionally, L1 + L2 + 5 = 15.0 in. Therefore, L1 = 7.6 in. and L2 = 2.4 in. Design: L1 = 8.0 in. and L2 = 3.0 in.
  • 31. Groove Welded Connections โ€ข Connects structural members that are aligned in the same plane โ€ข Basic Types: โ€“ Complete joint penetration groove weld: transmits full load of the member they join and have the same strength as the base metal. โ€“ Partial penetration groove weld: Welds do not extend completely through the thickness of the pieces being joined.
  • 32. Groove Welds Complete penetration groove welded connections โ€ข Tension and compression loaded โ€“ Factored resistance = factored resistance of base metal โ€ข Shear loaded on effective area ๏ƒ  lesser of โ€“ Factored resistance of weld = 0.6 x fe1 x Fexx = 0.6 x 0.85 x Fexx โ€“ 60% of factored resistance of base metal in tension Partial penetration groove-welded connections โ€ข Tension or compression parallel to the weld axis and compression normal to effective area ๏ƒ  factored resistance of the base metal โ€ข Tension normal to the effective area ๏ƒ  lesser of โ€“ Factored resistance of the weld = 0.6 fe2 Fexx = 0.60 x 0.80 x Fexx โ€“ Factored resistance of the base metal โ€ข Shear loaded ๏ƒ  lesser of โ€“ Factored resistance of the weld = 0.6 fe2 Fexx = 0.60 x 0.80 x Fexx โ€“ Factored resistance of base metal = 0.58 Fy