2. About Lincoln Associates
Lincoln Associates is a manufacturer's representative specializing in HVAC&R for industrial and
commercial applications. Since 1972, Lincoln Associates has combined quality products with quality
engineering to become one of the industry's leading sellers of HVAC&R equipment. With over 10,000
applications installed and an experienced, diversified staff, we truly do sell solutions to problems.
Lincoln Associates has served the industry for over 43 years with an experienced staff of sales engineers
holding degrees in mechanical and industrial engineering, business and marketing. We offer engineered
solutions to industrial end users, design-build mechanical contractors, and architectural and
engineering firms.
3. About Lincoln Associates
The lines represented include:
Industrial grade heating
Humidification
Dehumidification
Direct-fired and indirect-fired makeup air units
Air turnover units
Infrared heating systems
Fluid coolers
Evaporative coolers
Water chillers
Refrigeration products
Custom coils, including fluid, DX, standard steam, steam distributing, condenser, heat reclaim, and more
6. Air Turnover, Indirect and
Direct Fired Systems
Cooling only
Heating and Cooling
Heating Only
Direct Fired and Indirect Fired
7. Unit Heaters
Light Commercial
FSA - 30 to 75 MBH Input
FOA – 45 to 300 MBH Input
Commercial Warehouse
SEP 100 to 400 MBH Input
HED 75 to 300 MBH
NG or LP
8. LJ Wing Unit Heaters
Steam/Hot Water Unit
Heaters
Mounting heights of up to 73 feet
while maintaining near zero
stratification
High Level Circulators
Draw in, and then redistribute to the
floor
High Mounted Series
Heaters
Gas-Fired Unit Heater
12. CORAYVAC® High Efficiency Infrared Heating
CORAYVAC® is an energy efficient system due to its vacuum operated, burners-in-series design,
combined with its ability to condense. Lowering exhaust temperatures puts more heat in the
space, less wasted through the exhaust, helping result in additional efficiency and fuel savings.
Custom Design System
Burners-In-Series
Reduces Building Penetrations
Vacuum Operated
More Heat in Space
Fuel Savings
13. Located from 10 ft. - 70 ft. (3 m to 21.3 m) apart
VACUUM PUMPS A vacuum pump draws the heat
throughout the entire system. It exhausts products of
combustion to the outdoors at temperatures typically
below 150° F (66° C)
17. Unique Solutions for
Challenging HVAC Projects
• Modular HVAC Equipment featuring All-Indoor Components
• Vertical and Horizontal Models from 1 to 70 Ton Capacity
• Fully Packaged or Split Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Models
• Extensive Options along with VAV and 100% Outside Air Systems
• Specialize in Cost-Effective Retrofit Product Solutions
United CoolAir manufactures 1 to 70 ton "All-Indoor" Modular HVAC Solution systems for Commercial & Industrial
Cooling as well as 100% Outside Air applications. Built to order horizontal and vertical systems are available as
Air-Cooled, Water-Cooled, Chilled Water, and Heat Pump models with a wide range of options to meet almost any
application. The use of resealable refrigerant fittings makes systems ideal for retrofit and renovation projects with
lower total installed costs than many conventional replacements.
18. NEED TO REPLACE A SWUD, BLAZER OR BOHN?
United CoolAir has the solution.
Replacing a Mammoth V-Cube (V3) unit? Use our Varicool or EZFit series!
Replacing a Trane SWUD, Blazer unit, Bohn? EZFit series!
Replacing a McQuay SWP/SWT, use our Varicool or EZFit series!
19. VARICOOL MODEL: Shaped more cube
Matches the SWP, V3
EZFIT MODEL: “Long and Narrow”
Matches Blazer, SWUD, BOHN
21. Did you know we can provide you a 70 ton Unit that can be rigged and installed onto a 10th floor
mechanical room by 3-4 men in one day?
Here’s how:
• Each section is a completely tested and charged box with structural integrity sized to fit through a 36"
door. (90 minutes)
• Temporarily hang the fan section from the ceiling (1 hour)
• Place the coil and compressor sections below and drop the fans on top. UNITS ARE SHIPPED CHARGED!
Simply thread the pieces together, tie the wiring to the fans and use the molex connectors for the control
wiring. (90 minutes)
• Hook up the power, duct connections, and single point condenser water connections and you are all set!
(4 hours)
• Water side economizer? Its inside and already valved, piped and wired
• BMS? Available with a network card with all the usual protocols (BACNET IP or MSTP, LON, etc)
• Heat options are available: Single point electric, Hot Water and Steam
22. Resealable Refrigerant
Fittings
C-Family
Multi-sectional Models come with Quick
Connect. This means no field brazing,
evacuation or charging resulting in a total
installed cost advantage. Unit sections can
be shipped split or split in the field without
losing the factory charge.
23. Air-Cooled Vertical Packaged
System and
Water-Cooled VariCool VAV System
shown.
Not to scale. For illustrative purposes only.
Water Lines
Packaged or Splittable Vertical Systems
ALL-INDOOR
28. LJ Wing Coils
IFB Integral Face & Bypass
Coils
VIFB Vertical Integral Face
& Bypass Coils
MV-Series Multi-Header
Vertical Face & Bypass
Coils
Ideally suited for make-up air, combustion air make-up, penthouse units, air conditioning
preheat and heating and ventilating units.
29. Specialty Coils
Cooney Freeze Block Coil
Freeze damage is one of the leading causes of coil failure in the
HVAC industry. Although freeze-stats, expensive controls, preheat
coils, and glycol are commonly used, fluid coils frequently freeze
and rupture, resulting in equipment down-time and costly repairs
from the resulting water damage. More reliable technology for
damage protection is now available.
The Cooney Freeze Block by Coilmaster is designed to allow ice to
form within the tubes, without restriction, by discharging a small
amount of water into the drain pan. Therefore, the ice has enough
room to form inside the tubes, without causing damage to the
tubes.
31. Drake Chillers
• Air Cooled Packaged and Splits 1-
60hp
• Packaged Water Cooled 1-60hp
• Value line – Packaged Air Cooled 1-
12hp
• Fractional – ¼ - 1hp
• Semi-Hermetic. Packaged and splits
1 – 140 Hp
• Semi – Hermetic. Water Cooled
Chillers 1 – 140hp
• Tanks and pump packages
Drake Chillers represent the most high-quality, durable,
standard process chiller units on the market with cooling
capacities ranging from 1/4 ton to 106 tons and are
available for quick delivery. Our business is built on
outstanding after-the-sale technical support and customer
service. In other words… Our Customers’
Satisfaction Is Our Number One Priority!
33. Indirect and Direct Fired
Units. Make-Up Air Units
Applied Air
The Fresh Air Package (FAP) is a packaged
DOAS (Dedicated Outdoor Air System) from
Applied Air.
34. ARES
AIR REPLACEMENT ENGINEERED SYSTEMS
• Packaged Make-Up Air Systems Designed to make a more
comfortable and productive work environment. Whether for
ventilation and cooling in warmer climates, or heating in
colder climates, ARES offers proven solutions for your
workplace environment in a variety of performance and
capabilities.
• Modular combination of sections to provide
combinations of evaporative cooling, mechanical
cooling, ventilation and heating. Custom features in a
packaged approach.
37. MECHANICAL COOLING:
Cooling Coil & Cabinet Module
– DX and Chilled Water cooling
– Up to 6,000 CFM or 15 Tons Cooling
– Stainless Steel Pan (12 year Warranty)
– Copper tube, aluminum fin coils
– ARI Certified Coils
38. LJ Wing Make-Up Air
Steadyair - Air
Tempering Package Fresh Air Supply Units
WDF Direct-Gas Fired
Heaters
Integral Face and By-
Pass coil
Integral face and bypass
dampers with either steam
or hot water
Direct-gas fired heaters
39. • Economy Make-up air fans –
Mushroom
• Inline Filtered Make up air fans –
untampered 1 – 7,000 cfm
• Modular Packaged Units.
360 to 600 cfm/ton of cooling
• Rooftop Filtered 2 – 22,000 cfm
Economy Make-Up Air - No Motor
43. EVAPORATIVE COOLING
• Natures way to comfort cooling
• Environmentally friendly, no CFC’s
– Water, re-circulating pump and blower
• Direct adiabatic cooling adds humidity
• Indirect sensible cooling no add humidity
• Lowers Energy usage
– Reduced Energy Use 65-80% of mechanical
– Increases EER of mechanical equipment
– Helps achieve LEED accreditation
44. EVAPORATIVE COOLING
Direct
• Adiabatic cooling, constant enthalpy
• Cools through change of state
• Saturation efficiency of 80 to 95%
• Building temperatures 75-85 degrees
• Building relative humidity 60-80%
• Requires relief or powered exhaust
• Low first cost and operating costs
45. BAROMETRIC PRESSURE: 29.921 IN. OF MERCURY
PSYCHROMETRIC CHART
NORMAL TEMPERATURE
I-P Units
SEA LEVEL
-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130
DRY BULB TEMPERATURE - °F
ENTHALPY-BTUPERPOUNDOFDRYAIR
.05
.10
.15
.20
.25
.30
.35
.40
.45
.50
.55
.60
.65
.70
.75
.80
.85
.90
.95
1.00
1.05
1.10
1.15
VAPORPRESSURE-INCHESOFMERCURY
0
10
20
25
30
35
40
45
50
55
60
65
70
75
80
DEWPOINTTEMPERATURE-°F
Chart by: HANDS DOWN SOFTWARE, www.handsdownsoftware.com
1.00
0.95
0.90
0.85
0.80
0.75
0.70
0.65
0.60
0.55
0.50
0.450.400.350.300.250.20
SENSIBLE HEAT RATIO = Qs / Qt
SENSIBLEHEATRATIO=Qs/Qt
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
-15 -10 -5
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
HUMIDITYRATIO-GRAINSOFMOISTUREPERPOUNDOFDRYAIR
0
1.0 1.0 -::
SENSIBLE HEAT Qs
TOTAL HEAT Qt
ENTHALPY
HUMIDITY RATIO
Dh
DW
OSA
LAT
Chart by: HANDS DOWN SOFTWARE, www.handsdownsoftware.com
BAROMETRIC PRESSURE: 29.921 IN. OF MERCURY
PSYCHROMETRIC CHART
NORMAL TEMPERATURE
I-P Units
SEA LEVEL
Chart by: HANDS DOWN SOFTWARE, www.handsdownsoftware.com
EVAPORATIVE COOLING
Direct Evap. Performance
• OSA = 105 Db /72 Wb F
• 33 degree depression
• 88% efficiency
• 33 x .88 = 29 degree F
• Direct LAT = 76 / 72 F
COOLING EFFECTIVENESS
• 27 TONS BASED ON 10,000 CFM
• 36 GPH OR 0.6 GPM
EVAPORATION
•COST TO OPERATE PER HR. $2.25
BAROMETRIC PRESSURE: 29.921 IN. OF MERCURY
PSYCHROMETRIC CHART
NORMAL TEMPERATURE
I-P Units
SEA LEVEL
40
45
50
50
55
55
ENTHALPY-BTUPERPOUNDOFDRYAIR
0
5
10
15
20
25
30
35
40
45
ENTHALPY-BTUPERPOUNDOFDRYAIR
SATURATIONTEMPERATURE-°F
.05
.10
.15
.20
.25
.30
.35
.40
.45
.50
.55
.60
.65
.70
.75
.80
.85
.90
.95
1.00
1.05
1.10
1.15
VAPORPRESSURE-INCHESOFMERCURY
0
10
20
25
30
35
40
45
50
55
60
65
70
75
80
DEWPOINTTEMPERATURE-°F
1.00
0.95
0.90
0.85
0.80
0.75
0.70
0.65
0.60
0.55
0.50
0.450.400.350.300.250.20
SENSIBLE HEAT RATIO = Qs / Qt
SENSIBLEHEATRATIO=Qs/Qt
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
15%
25%
2%
4%
6%
8% RELATIVE HUMIDITY
10% RELATIVE HUMIDITY
20%
30%
40%
50%
60%
70%
80%
90%
-15 -10 -5
0
0
5
5
10
10
15
15
20
20
25
25
30
30
35
35
40
40
45
45
50
50
55
55
60
60
65
65
70
70
75
75
80
W
ET
BU
LB
TEM
PER
ATU
R
E
-°F
80
85
12.0
13.0
14.0VOLUME-CU.FT.PERLB.DRYAIR
HUMIDITYRATIO-GRAINSOFMOISTUREPERPOUNDOFDRYAIR
0
1.0 1.0
-
2.0
4.0
8.0
-8.0
-4.0
-2.0
-1.0
-0.5
-0.4
-0.3
-0.2
-0.1
0.1
0.2
0.3
0.4
0.5
0.6
0.8
-2000
-1000
0
500
1000
1500
2000
3000
5000
-
SENSIBLE HEAT Qs
TOTAL HEAT Qt
ENTHALPY
HUMIDITY RATIO
h
W
OSA
LAT
BAROMETRIC PRESSURE: 29.921 IN. OF MERCURY
PSYCHROMETRIC CHART
NORMAL TEMPERATURE
I-P Units
SEA LEVEL
48. Indirect/Direct Evaporative Unit
Integral Cross Flow
Cooling Tower
Supply Air Inlet Louvers (both
sides), Hinged one side for Filter
Access
2” Flat Bank Filter
Section
Copper Tube/Aluminum Fin Coil
for Indirect Evaporative Cooling
Stainless Steel Direct
Evaporative Cooling Section
(2A11 Series Only)
Direct Drive Plenum
Fan (or Fan Array)
Optional Return
Air Dampers
Bottom or End
Discharge
Standard: VFD for supply fan & DDC
controls
Optional: CW/DX coil, VFD for cooling
tower fan, Htg., WebCTRL
Cooling
Tower
Media
48
51. Mars Air Doors ETL Sanitation Certified - LoPro (LPN2)
Mars Air Curtains can
be used in a variety of
different applications
and industries.
Phantom 10 (PH10)
ETL Sanitation Certified –
Front Door (N2)
Wind Stopping 16 (WMH)
• LoPro Series
• ETL Sanitation Certified
• Phantom Series
• Extra Power
• High Velocity
• Wind Stopping
• Wind Guard
• Configurator, ROI Calculator