Case Study
Electrical Houses, DSL Cages & Control Cabs
for Ladle Furnace Cranes
Process Details: `Electrical Houses, DSL Cages & Control Cabs' for three `Ladle Furnace Cranes' currently in
service at the `Stainless Melting & Continuous Casting' facility operated by the UK based `Long Products
Division' of the worlds leading stainless steel producer.
Scope of Work: To design & manufacture the equipment to the customer's specific requirements, following
independent structural engineers criteria, considering material specification, surface preparation, protective
coatings and the friction grip / through hardened type fixing arrangements necessary to safely suspend all the
equipment from the cranes gantry beams - all programmed to meet a very short delivery time-scale for
installation during the customer's summer shut-down period.
Design Considerations: -
• All items to be of a robust and durable design, suitable for operation in the noisy, dirty & dusty conditions
associated with this heavy industry, and fit for purpose in providing a safe working environment for
operators and maintenance personnel alike, whilst reducing internal crane cab noise levels.
• Electrical Houses comprised of a structural steel skeleton over-clad in heavy gauge steel plate (fully
stiffened to accommodate control panels & electrical switchgear) with personnel / emergency exit door, a
central gangway complete with stanchions, handrailing etc., an internal runway beam & electrical hoist,
numerous sealed service(s) apertures and electrical safety matting to floor.
• DSL Cages manufactured in a similar fashion to the Electrical Houses, designed to carry the necessary
equipment to facilitate the transfer of electrical power from the `Down Shop Lead / Busbar' system.
• Crane Cabs comprised of a complex structural steel skeleton with acoustic infill panels & personnel door,
protected by a heat shield suspended beneath, and fitted with inward-opening (for cleaning from within the
cab) triple-glazed projectile-safe windows to walls & floor areas (safety grilles at floor level) having
sacrificial outer panes - all to provide the correct lines of vision. Installation of lighting & power, an internal
monorail system & electric chain hoist, ventilation ports for integration with an existing air conditioning
system, rubber floor matting, operator swivel chair & trainee's fold-up seat completed the turnkey package.
Acoustic Performance: An external noise level of 95dB(A) was reduced to 65dB(A) inside the Crane Cab, well
below the customer target noise level of 70dBA and the First Exposure Action Level (80dBA) of the Control of
Noise At Work Regulations 2005, reducing the operator's daily noise exposure and allowing him to effectively
communicate by radio in a stress-free, comfortable environment.
Acoustic Applications is the trading name of Xtron Systems Limited
Unit 8, Caldervale Road, Horbury Junction Industrial Estate, Wakefield, West Yorkshire, WF4 5ER.
Telephone No. +44 (0) 1924 26 21 65 Facsimile No. +44 (0) 1924 26 48 17
England & Wales Company Registration No. 06986821 - VAT Registration No. GB 981 1986 80

More Related Content

More from Christian Senior

C5193 Case Study - Tube Inside Diameter Welding Control Cabs
C5193 Case Study - Tube Inside Diameter Welding Control CabsC5193 Case Study - Tube Inside Diameter Welding Control Cabs
C5193 Case Study - Tube Inside Diameter Welding Control CabsChristian Senior
 
C5269 Case Study - Acoustically Insulated Test Chamber for a `Rotor Spin Rig ...
C5269 Case Study - Acoustically Insulated Test Chamber for a `Rotor Spin Rig ...C5269 Case Study - Acoustically Insulated Test Chamber for a `Rotor Spin Rig ...
C5269 Case Study - Acoustically Insulated Test Chamber for a `Rotor Spin Rig ...Christian Senior
 
C5250 Case Study - ID Grinding Robot Control Cabin
C5250 Case Study - ID Grinding Robot Control CabinC5250 Case Study - ID Grinding Robot Control Cabin
C5250 Case Study - ID Grinding Robot Control CabinChristian Senior
 
C5267 Case Study - Acoustic Enclosure for SRSM Air Blast Drying Process
C5267 Case Study - Acoustic Enclosure for SRSM Air Blast Drying ProcessC5267 Case Study - Acoustic Enclosure for SRSM Air Blast Drying Process
C5267 Case Study - Acoustic Enclosure for SRSM Air Blast Drying ProcessChristian Senior
 
C5111 Case Study - Acoustic enclosure for a Horizontal Balancing Machine
C5111 Case Study - Acoustic enclosure for a Horizontal Balancing MachineC5111 Case Study - Acoustic enclosure for a Horizontal Balancing Machine
C5111 Case Study - Acoustic enclosure for a Horizontal Balancing MachineChristian Senior
 
C4958 Case Study - Acoustic Booths for Speakers
C4958 Case Study - Acoustic Booths for SpeakersC4958 Case Study - Acoustic Booths for Speakers
C4958 Case Study - Acoustic Booths for SpeakersChristian Senior
 
C4950 Case Study #1 - Mess Facilities for Furnace Control Rooms
C4950 Case Study #1 - Mess Facilities for Furnace Control RoomsC4950 Case Study #1 - Mess Facilities for Furnace Control Rooms
C4950 Case Study #1 - Mess Facilities for Furnace Control RoomsChristian Senior
 
C4959 Case Study - Vac Pump Enclosure
C4959 Case Study - Vac Pump EnclosureC4959 Case Study - Vac Pump Enclosure
C4959 Case Study - Vac Pump EnclosureChristian Senior
 
C4494 Case Study - Caster Control Complex
C4494 Case Study - Caster Control ComplexC4494 Case Study - Caster Control Complex
C4494 Case Study - Caster Control ComplexChristian Senior
 
C4359 Case Study - Noise Barrier Screening
C4359 Case Study - Noise Barrier ScreeningC4359 Case Study - Noise Barrier Screening
C4359 Case Study - Noise Barrier ScreeningChristian Senior
 
C4905 Case Study - Welding Control Pulpit
C4905 Case Study - Welding Control PulpitC4905 Case Study - Welding Control Pulpit
C4905 Case Study - Welding Control PulpitChristian Senior
 
C4706 Case Study - Acoustic Screen with Chevron Louvres
C4706 Case Study - Acoustic Screen with Chevron LouvresC4706 Case Study - Acoustic Screen with Chevron Louvres
C4706 Case Study - Acoustic Screen with Chevron LouvresChristian Senior
 
C5169 Case Study - Acoustic enclosure for a Horizontal Balancing Machine
C5169 Case Study - Acoustic enclosure for a Horizontal Balancing MachineC5169 Case Study - Acoustic enclosure for a Horizontal Balancing Machine
C5169 Case Study - Acoustic enclosure for a Horizontal Balancing MachineChristian Senior
 
C4917 Case Study - Acoustic enclosures for Plasma Cutting Machines
C4917 Case Study - Acoustic enclosures for Plasma Cutting MachinesC4917 Case Study - Acoustic enclosures for Plasma Cutting Machines
C4917 Case Study - Acoustic enclosures for Plasma Cutting MachinesChristian Senior
 

More from Christian Senior (14)

C5193 Case Study - Tube Inside Diameter Welding Control Cabs
C5193 Case Study - Tube Inside Diameter Welding Control CabsC5193 Case Study - Tube Inside Diameter Welding Control Cabs
C5193 Case Study - Tube Inside Diameter Welding Control Cabs
 
C5269 Case Study - Acoustically Insulated Test Chamber for a `Rotor Spin Rig ...
C5269 Case Study - Acoustically Insulated Test Chamber for a `Rotor Spin Rig ...C5269 Case Study - Acoustically Insulated Test Chamber for a `Rotor Spin Rig ...
C5269 Case Study - Acoustically Insulated Test Chamber for a `Rotor Spin Rig ...
 
C5250 Case Study - ID Grinding Robot Control Cabin
C5250 Case Study - ID Grinding Robot Control CabinC5250 Case Study - ID Grinding Robot Control Cabin
C5250 Case Study - ID Grinding Robot Control Cabin
 
C5267 Case Study - Acoustic Enclosure for SRSM Air Blast Drying Process
C5267 Case Study - Acoustic Enclosure for SRSM Air Blast Drying ProcessC5267 Case Study - Acoustic Enclosure for SRSM Air Blast Drying Process
C5267 Case Study - Acoustic Enclosure for SRSM Air Blast Drying Process
 
C5111 Case Study - Acoustic enclosure for a Horizontal Balancing Machine
C5111 Case Study - Acoustic enclosure for a Horizontal Balancing MachineC5111 Case Study - Acoustic enclosure for a Horizontal Balancing Machine
C5111 Case Study - Acoustic enclosure for a Horizontal Balancing Machine
 
C4958 Case Study - Acoustic Booths for Speakers
C4958 Case Study - Acoustic Booths for SpeakersC4958 Case Study - Acoustic Booths for Speakers
C4958 Case Study - Acoustic Booths for Speakers
 
C4950 Case Study #1 - Mess Facilities for Furnace Control Rooms
C4950 Case Study #1 - Mess Facilities for Furnace Control RoomsC4950 Case Study #1 - Mess Facilities for Furnace Control Rooms
C4950 Case Study #1 - Mess Facilities for Furnace Control Rooms
 
C4959 Case Study - Vac Pump Enclosure
C4959 Case Study - Vac Pump EnclosureC4959 Case Study - Vac Pump Enclosure
C4959 Case Study - Vac Pump Enclosure
 
C4494 Case Study - Caster Control Complex
C4494 Case Study - Caster Control ComplexC4494 Case Study - Caster Control Complex
C4494 Case Study - Caster Control Complex
 
C4359 Case Study - Noise Barrier Screening
C4359 Case Study - Noise Barrier ScreeningC4359 Case Study - Noise Barrier Screening
C4359 Case Study - Noise Barrier Screening
 
C4905 Case Study - Welding Control Pulpit
C4905 Case Study - Welding Control PulpitC4905 Case Study - Welding Control Pulpit
C4905 Case Study - Welding Control Pulpit
 
C4706 Case Study - Acoustic Screen with Chevron Louvres
C4706 Case Study - Acoustic Screen with Chevron LouvresC4706 Case Study - Acoustic Screen with Chevron Louvres
C4706 Case Study - Acoustic Screen with Chevron Louvres
 
C5169 Case Study - Acoustic enclosure for a Horizontal Balancing Machine
C5169 Case Study - Acoustic enclosure for a Horizontal Balancing MachineC5169 Case Study - Acoustic enclosure for a Horizontal Balancing Machine
C5169 Case Study - Acoustic enclosure for a Horizontal Balancing Machine
 
C4917 Case Study - Acoustic enclosures for Plasma Cutting Machines
C4917 Case Study - Acoustic enclosures for Plasma Cutting MachinesC4917 Case Study - Acoustic enclosures for Plasma Cutting Machines
C4917 Case Study - Acoustic enclosures for Plasma Cutting Machines
 

C4743 Case Study - Control Cabs, Electrical Houses & DSL Cages for Ladle Cranes

  • 1. Contact us for your industrial noise solutions. +44 (0) 1924 26 21 65 sales@acousticapplications.co.uk Case Study Electrical Houses, DSL Cages & Control Cabs for Ladle Furnace Cranes Process Details: `Electrical Houses, DSL Cages & Control Cabs' for three `Ladle Furnace Cranes' currently in service at the `Stainless Melting & Continuous Casting' facility operated by the UK based `Long Products Division' of the worlds leading stainless steel producer. Scope of Work: To design & manufacture the equipment to the customer's specific requirements, following independent structural engineers criteria, considering material specification, surface preparation, protective coatings and the friction grip / through hardened type fixing arrangements necessary to safely suspend all the equipment from the cranes gantry beams - all programmed to meet a very short delivery time-scale for installation during the customer's summer shut-down period. Design Considerations: - • All items to be of a robust and durable design, suitable for operation in the noisy, dirty & dusty conditions associated with this heavy industry, and fit for purpose in providing a safe working environment for operators and maintenance personnel alike, whilst reducing internal crane cab noise levels. • Electrical Houses comprised of a structural steel skeleton over-clad in heavy gauge steel plate (fully stiffened to accommodate control panels & electrical switchgear) with personnel / emergency exit door, a central gangway complete with stanchions, handrailing etc., an internal runway beam & electrical hoist, numerous sealed service(s) apertures and electrical safety matting to floor. • DSL Cages manufactured in a similar fashion to the Electrical Houses, designed to carry the necessary equipment to facilitate the transfer of electrical power from the `Down Shop Lead / Busbar' system. • Crane Cabs comprised of a complex structural steel skeleton with acoustic infill panels & personnel door, protected by a heat shield suspended beneath, and fitted with inward-opening (for cleaning from within the cab) triple-glazed projectile-safe windows to walls & floor areas (safety grilles at floor level) having sacrificial outer panes - all to provide the correct lines of vision. Installation of lighting & power, an internal monorail system & electric chain hoist, ventilation ports for integration with an existing air conditioning system, rubber floor matting, operator swivel chair & trainee's fold-up seat completed the turnkey package. Acoustic Performance: An external noise level of 95dB(A) was reduced to 65dB(A) inside the Crane Cab, well below the customer target noise level of 70dBA and the First Exposure Action Level (80dBA) of the Control of Noise At Work Regulations 2005, reducing the operator's daily noise exposure and allowing him to effectively communicate by radio in a stress-free, comfortable environment. Acoustic Applications is the trading name of Xtron Systems Limited Unit 8, Caldervale Road, Horbury Junction Industrial Estate, Wakefield, West Yorkshire, WF4 5ER. Telephone No. +44 (0) 1924 26 21 65 Facsimile No. +44 (0) 1924 26 48 17 England & Wales Company Registration No. 06986821 - VAT Registration No. GB 981 1986 80