This document describes the development and validation of a reverse phase high performance liquid chromatography (RP-HPLC) method for the simultaneous quantification of hydrochlorothiazide and eprosartan in bulk drug and pharmaceutical formulations. The method utilizes a C18 column with a mobile phase of 50mM KH2PO4 (pH 4.0) and acetonitrile in a 30:70 ratio at a flow rate of 1 mL/min. Hydrochlorothiazide and eprosartan were detected at 270nm and the method was linear over a range of 5-25 μg/mL and 8-40 μg/mL, respectively. The developed method was successfully applied for the analysis of a marketed tablet
Hierarchy of management that covers different levels of management
6. Research Arun Patel(1).pdf
1. *Corresponding Author: Arun Patel, Email: arun.patelnsp@gmail.com
ISSN 0976 – 3333
RESEARCH ARTICLE
Available Online at www.ijpba.info
International Journal of Pharmaceutical & Biological Archives 2017; 8 (1): 28-33
Simultaneous Determination and Validation of Hydrochlorothiazide & Eprosartan in bulk drug
and Marketed Formulation by Rp-Hplc
1
Arun Patel*, 2
Neelesh Dwivedi, 3
Shailendra Patel, 4
Sunil Bashani, 5
Vaibhav Tiwari
1
*Pharmacy department, Shri Ram Group of Institute Faculty of Pharmacy, Jabalpur, 482002, M.P.,
India.
2
HOD Pharmacy Depatment Shri Ram Group of Institute Faculty of Pharmacy, Jabalpur, 482002, M.P
3, 4,5Assistanat
professor Pharmacy Depatment Shri Ram Group of Institute Faculty of Pharmacy, Jabalpur,
482002, M.P
Received 22 Jan 2016; Revised 18 Oct 2016; Accepted 05 Jan 2017
ABSTRACT
Validation of developed and RP HPLC analytical method according to ICH Guidelines. A review of
literature reveals that no analytical methods are available for these drugs. There are no methods in the
literature for the estimation of drugs in combined dosage forms. Analytical methods have been report for
hydrochlorothiazide and eprosartan using RP-HPLC in pharmaceutical dosage form. The development of
simple and precise reverse phase high performance liquid chromatography of hydrochlorothizide and
eprosartan using single method in bulk in bulk drug and market formulation.
Key Words- Hydrochlorothizide, Eprosartan, RP- HPLC
INTRODUCTION
Chromatography is a non-destructive procedure
for resolving a multi-component mixture of trace,
minor, or major constituents into its individual
fractions. Different variations may be applied to
solids, liquids, and gases. While chromatography
may be applied both qualitatively and
quantitatively, it is primarily a separation tool.
Quantitative analysis can be carried out by
measuring the area of the chromatographic peak.
Chromatography may be defined as a method of
separating a mixture of components into
individual components through equilibrium
distribution between two phases.
The chromatographic method of separation, in
general, involves the following steps:
Adsorption or retention of a substance or
substances on the stationary phase.
Separation of the adsorbed substances by the
mobile phase.
Recovery of the separated substances by a
continuous flow of the mobile phase; the
method being called elution.
Qualitative and quantitative analysis of the
eluted substances1.
PRINCIPLE OF SEPARATION IN HPLC
The principle of separation in normal phase mode
and reverse phase mode is adsorption. When
mixtures of components are introduced in to a
HPLC column, they travel according to their
relative affinities towards the stationery phase.
The component which has more affinity towards
the adsorbent travels slower. The component
which has less affinity towards the stationary
phase travels faster. Since no two components
have the same affinity towards the stationary
phase, the components are separated.
The most important component of HPLC in
solvent delivery system is the pump, because its
performance directly effects the retention time,
reproducibility and detector sensitivity. Among
the several solvent delivery systems (direct gas
pressure, pneumatic intensifier, reciprocating etc.)
reciprocating pump with twin or triple pistons is
widely used, as this system gives less baseline
noise, good flow rate reproducibility etc.
MATERIALS
Table No. 1. Chemicals and Solvents Used
S. No. Chemicals Manufacture
01 Eprosartan Macleod’s Pharmaceutical
Ltd.
02 Hydrochlorothiazide Kalindi Medicure Pvt. Ltd.
03 3 Acetonitrile Merck Ltd., India