CONTENTS
I. Stand-alone node set-up.........................................................................................................................2
II. Configure the software environment and load, and commit the software........................................5
1. WebUI procedure:..............................................................................................................................6
2. CLI procedure : ..................................................................................................................................9
III. Set the NE to operate in SDH mode................................................................................................13
1. CLI procedure : ................................................................................................................................13
IV. Set the loopback IP address.............................................................................................................14
1. WebUI procedure :...........................................................................................................................14
2. CLI procedure : ................................................................................................................................14
V. Configure GNE for management system access................................................................................15
1. WebUI procedure :...........................................................................................................................15
2. CLI procedure : ................................................................................................................................18
VI. Complete connection of inventory cables .......................................................................................18
1. WebUI Procedure :...........................................................................................................................18
2. CLI procedure : ................................................................................................................................20
VII. Insert duplicate equipment controller ............................................................................................21
VIII. Set the network element date and time...........................................................................................22
1. WebUI procedure :...........................................................................................................................22
2. CLI procedure : ................................................................................................................................23
IX. Disable ES port monitoring .............................................................................................................23
1. WebUI procedure :...........................................................................................................................23
2. CLI procedure : ................................................................................................................................24
X. Update firmware on all circuit packs .................................................................................................24
1. WebUI procedure :...........................................................................................................................24
2. CLI procedure : ................................................................................................................................25
XI. Configure additional system properties..........................................................................................25
1. WebUI procedure :...........................................................................................................................26
2. CLI procedure ..................................................................................................................................26
2
I. Stand-alone node set-up
 Connect one end of the Ethernet cable to the CIT port on the active EC card (indicated by green
Active LED) on the master shelf. Connect the other end of the cable to the Ethernet port on your
PC.
 Open a PC command window and type ipconfig and <Enter>. Verify the IP address assigned
by the NE to your PC is 172.16.0.x.
 Launch Internet Explorer and enter http://172.16.0.1 in the Address bar. This is the
default IP address of the CIT port.
Note: Make sure Internet Explorer is not using a proxy server to access this address.
 Click Go. The browser connects to the network element and the WebUI login window is displayed.
3
 Initialize the database
A warning message will indicating that the database is uninitialized.
 If the warning message does not appear, this is an indication that there is a database already on the
EC.
USE:(
 Use a telnet application on your PC and open a telnet session connected to the IP address of the
CIT port.
• The default address for an uncommissioned NE is 172.16.0.1
 Hit <Enter> and the login: prompt will appear. Type cli and <Enter>.
 Type cli at the Password: prompt and <Enter>.
 This starts the CLI, and another Username: prompt will appear. Type admin and
<Enter>.
 Type config database clear.
)
 Click “OK” and the system will automatically restart after initialization. A window will appear
showing the restart progress.
4
 After the restart is complete, the system will prompt you for a new NE name. Type the NE name.
 Click the “Submit” button and the system will restart once again. The restart will take
approximately 2 minutes.
 After the restart is complete, the WebUI will open with the system properties view.
5
II. Configure the software environment and load,
and commit the software.
 Start the FTP server application on your PC and create a user account. Record the userid and
password established for the account.
 Establish a root directory for the server and make sure it has read and write privileges. You may
create a folder in the root directory that will contain the NE software.
 Copy the folder and subfolders with the NE software into the FTP root directory
established above.
Note: The software folder name to be copied is 1830PSS32-3.0-00. There should
also be two subfolders named “1830PSS32” and “1830PSS32M” as well as a
CATALOG file.
 Open Windows Firewall from the Control Panel.
 Select Off. Then click OK.
 Open a PC command window and type ipconfig and <Enter>. Once again verify the IP address
assigned by the NE to your PC is 172.16.0.x.
6
Important! If this is an Alcatel-Lucent 1830 PSS-16 shelf, use the CLI
(command) procedure.
1. WebUI procedure:
 Select the Software menu item under Administration and then select FTP Server.
 The FTP server settings window appear.
7
 Enter NE IP address obtained earlier using ipconfig for the Server IP Address.
 Enter the path to the NE software relative to the server root directory in the “Root Directory” field.
Note: If the software folder was copied directly into the root directory, enter / in
this field.
 Enter the UserID and Password to match the account created on the FTP server.
 Click the “Apply” button.
 Select Administration -> Software -> Upgrade from the top menu.
 The Software Upgrade window appears.
Note: The software release will be the current factory load.
 Select “Audit” from the “Action Type” drop-down list.
 Enter the folder name containing the NE software in the “Release Directory” field. The folder
name for Release 3.0 should be 1830PSS32-3.0-00.
 Click “Apply” and the “Status” field will change to “In Progress”.
 Periodically click the “Refresh” button until the “Status” field changes to “Completed”.Verify the
“Result” is “Success” and the “Upgrade Path Available” field indicates “Yes”.
 Select “Download” for the “Action Type” and click “Apply”. The “Status” field will change
to “In Progress”.
 Periodically click the “Refresh” button until the “Status” field changes to “Completed”.Verify the
“Result” is “Success”.
8
 Select “Activate” for the “Action Type” and click “Apply”. The “Status” field will change to “In
Progress”. The NE will then reboot, and the WebUI will automatically logout.
 Wait about 2 minutes after the fan speed drops back down to normal speed and log back into the
NE (typically 10 minutes after activate).
 Return to the Software Upgrade window by selecting Administration -> Software -> Upgrade
from the top menu. Verify the “Status” field now indicates “Completed”, and verify the
“Result” is “Success’.
 Select “Commit” for the “Action Type” and click “Apply”. The “Status” field will change to “In
Progress”.
 Periodically click the “Refresh” button until the “Status” field changes to “Completed”.
Verify the “Result” is “Success”.
 Verify the Active and Committed releases have changed to the new release.
9
2. CLI procedure :
 Use a telnet application on your PC and open a telnet session connected to the IP address of the
CIT port.
• The default address for an uncommissioned NE is 172.16.0.1
 Hit <Enter> and the login: prompt will appear. Type cli and <Enter>.
 Type cli at the Password: prompt and <Enter>.
 This starts the CLI, and another Username: prompt will appear. Type admin and
<Enter>.
 Type config software server ip <ip> and <Enter>.
Where <ip> is the ip address of the PC with the FTP server. This is the same ip address
obtained using the ipconfig command in the PC command window.
 Type config software server userid <userid> and <Enter>.
Where <userid> is the user_id for the user account defined on the FTP server.
 Type <pw> and <Enter>.
Where <pw> is the password for the user account defined on the FTP server.
 Type config software server root <path> and <Enter>.
Where <path> is the path to the NE software relative to the server root directory.
Note: If the software folder was copied directly into the root directory, enter / for the
<path>.
 Type config software server detail and <Enter>.
Sample output below.
Software Server Protocol : FTP
Software Server IP : 172.16.0.2
Software Server Userid : sw1
Software Server Root Directory : /
 Verify the server settings are correct.
 Type config software upgrade status and <Enter>.
10
Sample output below.
Software Upgrade Information:
Software Server IP : 172.16.0.2
Software Server Root Directory : /
Committed Release :
Working Release Directory :
Working Release : 1830PSS32-0.00-7
Active Release : 1830PSS32-0.00-7/
Operation :
Operation Status :
Upgrade Path Available : True
Software Download Script (Timezone: ):
 Verify the current active software is an older release than software you are loading.
 Type config software upgrade manual audit <releasedir> nobackup and <Enter>.
Where <releasedir> is the directory name on the PC containing the software. The folder
name for Release 3.0 should be 1830PSS32-3.0-00.
 Type config software upgrade status and <Enter>.
A listing of packs will be displayed along with the status showing which packs need to be
upgraded. Sample output below.
Software Upgrade Information:
Software Server IP : 172.16.0.2
Software Server Root Directory : /SVT/
Committed Release :
Working Release Directory : 1830PSS32-0.00-7/
Working Release : 1830PSS32-0.00-7
Active Release : 1830PSS32-0.00-7
Operation : Audit
Operation Status : Completed
Upgrade Path Available : True
Software Download Script (Timezone: ):
Stage=0 Step=1 SH/SL: 1/1 CARDTYPE: EC
ACTION: Audit node Completed 100% complete
11
RESULT: Success
Stage=1 Step=0 SH/SL: 0/0 CARDTYPE: Empty
ACTION: Transfer to disk Planned 0% complete
RESULT: None
Stage=2 Step=0 SH/SL: 1/1 CARDTYPE: EC
ACTION: Activate Planned 0% complete
RESULT: None
Stage=3 Step=0 SH/SL: 1/2 CARDTYPE: AHPHG
ACTION: Activate Planned 0% complete
RESULT: None
Stage=3 Step=1 SH/SL: 1/3 CARDTYPE: CWR8
ACTION: Activate Planned 0% complete
RESULT: None
Stage=3 Step=2 SH/SL: 1/7 CARDTYPE: 11STAR1
ACTION: Activate Planned 0% complete
RESULT: None
Stage=3 Step=3 SH/SL: 1/13 CARDTYPE: 11STAR1
ACTION: Activate Planned 0% complete
RESULT: None
Stage=3 Step=5 SH/SL: 1/15 CARDTYPE: CWR8
ACTION: Activate Planned 0% complete
RESULT: None
Stage=3 Step=6 SH/SL: 1/17 CARDTYPE: ALPHG
ACTION: Activate Planned 0% complete
RESULT: None
 Repeat config software upgrade status until the Operation Status indicates Completed. Verify the
Upgrade Path Available changes to True.
 Type config software upgrade manual load and <Enter>. This will transfer the software to the NE.
 Type config software upgrade status and <Enter>. Watch for the following lines.
...
Operation : Load
Operation Status : In Progress 0%
...
 Continue to execute the status command until the Operation Status shows Completed.
12
 Type config software upgrade manual activate and <Enter>.
This will activate the software on the EC card.
 The NE will reboot and the telnet connection will drop. Wait about 2 minutes after the fan speed
drops back to normal speed and log back into the NE (typically 10 minutes after activate). Then
Connect to the NE for CLI access.
 Type config software upgrade status and <Enter>.Watch for the following lines.
...
Operation : Activate
Operation Status : In Progress 0%
...
 Continue to execute the status command until the Operation Status shows Completed.
Note: The output will also display the progress of the activation on each of the packs
in the NE. The Operation Status will not show completed until all packs have been
activated on the new release.
 Type config software upgrade commit and <Enter>. This will commit the software to be the
primary release.
 Type config software upgrade status and <Enter>. Watch for the following lines.
...
Operation : Commit
Operation Status : In Progress 0%
...
 Continue to execute the status command until the Operation Status shows Completed.
 After the last status command is executed, verify the new software release is displayed as the
committed, working and active release. See the sample output below.
Software Upgrade Information:
Software Server IP : 172.16.0.2
Software Server Root Directory : /
Committed Release : 1830PSS32-3.0-00
Working Release Directory : 1830PSS32-3.0-00/
Working Release : 1830PSS32-3.0-00
Active Release : 1830PSS32-3.0-00/
Operation : Commit
Operation Status : Completed
Upgrade Path Available : False
Software Download Script (Timezone: ):
13
 NOTE : If this is an Alcatel-Lucent 1830 PSS-16 shelf, the following command is required to
bring the node up as an Alcatel-Lucent 1830 PSS-16.
 Type config database clear and <Enter>.
The shelf will reboot and when the reboot completes the shelf will be correctly configured
as an Alcatel-Lucent 1830 PSS-16 shelf.
III. Set the NE to operate in SDH mode
Background
The NE defaults to SONET mode. You need to perform this procedure only if you want
the NE to operate in SDH mode.
NOTICE
This procedure should only be executed when a system is first turned up.
1. CLI procedure :
 Type show version and <Enter>.
Sample output:
Software Version: 1830PSS32-3.0-00
 Copy the string after “Software Version”. This will be used as the password for the SDH mode
command.
 Type config admin mode sdh <pw> and <Enter>.
Where <pw> is the password copied in the previous step.
 The following warning will appear.
WARNING: Changing the SONET/SDH mode will cause the database to be
cleared, the node to be cold reset and all services to be
deleted.
 Type yes and <Enter>. You will be logged out. This procedure is complete.
14
IV. Set the loopback IP address
1. WebUI procedure :
 Select “System” from the tree and the “Details” tab.
 At the “Loopback IP Address” field, enter the IP address designated in the site documentation.
 At the “Loopback Subnet Mask” field, enter the subnet mask designated in the site documentation.
 Click the “Submit” button.
 Click “OK.” The system will reboot, and WebUI will automatically logout.
 Wait for the system to reboot (watch for the CIT link light to turn green) and log back into the
WebUI.
2. CLI procedure :
 Type config interface loop ip <address>/<mask> and <Enter>.
Where <address> is the IP address and <mask> represents the subnet mask following the
CIDR format. Obtain this information from the site documentation.
15
 The following warning message will appear.
WARNING: Changing the loopback IP address will result
in a warm reset of this network element.
Enter 'yes' to confirm, 'no' to cancel:
 Type yes and <Enter>. The CLI session will be terminated.
V. Configure GNE for management system access
Purpose
This procedure will provision and enable the OAMP port so that the NE can act as a
Gateway Network Element. The procedure will also provision the IP route information to
allow connection to RNEs. Not all NEs (i.e. RNEs) require this provisioning. Refer to the
site documentation.
1. WebUI procedure :
 Expand “Shelf 1” in the equipment tree and then expand “slot 40: USRPNL” (slot 10 for PSS-16).
 Select OAMP. The OAMP port provisioning window will appear.
16
 Enter the IP address and subnet mask as indicated in the site documentation.
 Check the Port Enabled checkbox.
 Click the “Submit” button.
 Select Administration -> Networking -> IP Routes from the top menu.
 The IP Routes screen is displayed.
 Click the “Create” button. The Create IP Routes screen is displayed.
17
 Enter the parameters based on the site documentation.
 Click the “Apply” button.
 Verify the new IP route is now shown in the IP routes.
18
2. CLI procedure :
 Type config interface usrpnl oamp ip <address>/<mask> and <Enter>.
Where <address> is the IP address and <mask> represents the subnet mask following the
CIDR format. Obtain this information from the site documentation.
 Type config interface usrpnl oamp state up and <Enter>.
 Type config cn routes default add <address> and <Enter>.
Where <address> is the gateway address from the site documentation
 Type config interface usrpnl oamp rou en and <Enter>.
VI. Complete connection of inventory cables
Purpose
The inventory cables will be connected and DCM, SFD44, SFD44B, and ITLB units
discovered in this procedure following the site documentation.
Note: If the DCM, SFD44, SFD44B, and ITLB shelf numbering contains non
contiguous numbers (numbers are skipped), the shelves must be manually pre-
provisioned before the inventory cables are connected. This procedure takes care of
that case.
1. WebUI Procedure :
 Observe the equipment tree in the left window of the system view and verify there are no shelves
numbered 25 or greater.
19
 Refer to the site documentation to determine the shelf numbering of the DCM, SFD44,
SFD44B, and ITLB units. List them in order starting with 25.
 Does the shelf numbering contain non contiguous numbers (numbers are skipped)?
If yes, skip to steps between two ().
If no, continue.
 Determine the next sequential DCM, SFD44, SFD44B, or ITLB unit that has not been
discovered and connect the inventory cable to that unit.
 Wait 2 minutes and click the refresh button (the double arrows located at the top of the
equipment tree).
 The new shelf should appear in the tree with the appropriate shelf number. If not, repeat clicking
refresh If the shelf still does not appear, check the cable connection or replace the inventory
cable.
 Are there additional DCM, SFD44, SFD44B, or ITLB units to be discovered?
If yes, repeat the last 3 steps.
If no, end of steps.
 () In the System view, select the “Create Shelf” tab. The Create Shelf view will appear.
 Enter the appropriate provisioned type and shelf ID number of the next DCM, SFD44, SFD44B,
or ITLB shelf to be added. Enter additional parameters as required, then click the “Apply”
button.
 Repeat until all the DCM, SFD44, SFD44B, and ITLB shelves have been created.
 Close the create shelf window and verify all the DCM, SFD44, SFD44B, and ITLB shelves now
appear correctly in the equipment tree.
20
 Connect the inventory cables to all the DCM, SFD44, SFD44B, and ITLB units.
 Check the alarms on the system and verify there are no equipment alarms related to the DCM,
SFD44, SFD44B, or ITLB shelves. ()
2. CLI procedure :
 Type show shelf * and <Enter>.
Sample output.
Shelf 1 Information
Name : Master Shelf
Description : Master Shelf
ExpectedAmps : 30
Programmed Type : Universal Shelf Present Type : Universal
Shelf
 Verify there are no shelves number 25 or greater.
 Refer to the site documentation to determine the shelf numbering of the DCM, SFD44,
SFD44B, and ITLB units. List them in order starting with 25.
 Does the shelf numbering contain non contiguous numbers (numbers are skipped)?
If yes, skip to steps between two ().
If no, continue.
 Determine the next sequential DCM, SFD44, SFD44B, or ITLB unit that has not been
discovered and connect the inventory cable to that unit.
 Wait 2 minutes and type show shelf * and <Enter>.
 The new shelf should be listed in the output with the appropriate shelf number. If not, repeat
show shelf. If the shelf still does not appear, check the cable connection or replace the inventory
cable.
 Are there additional DCM, SFD44, SFD44B, or ITLB units to be discovered?
If yes, repeat the last 3 steps.
If no, end of steps.
21
 ()Type config shelf <shelf> type <type> and <Enter>.
Where <shelf> is the shelf number of the next shelf to be created and <type> is either dcm,
sfd44, sfd44b, or itlb.
 Repeat this step until all the DCM, SFD44, SFD44B, and ITLB shelves have been created.
 Type show shelf * and <Enter>.
 Verify all the shelves that were created are now listed correctly.
 Connect the inventory cables to all the DCM, SFD44, SFD44B, and ITLB units.
 Type alm and <Enter>.
 Verify there are no equipment alarms related to the DCM, SFD44, SFD44B, or ITLB shelves. ()
VII. Insert duplicate equipment controller
Purpose
In this procedure, the duplicate Equipment Controller (EC), if equipped, in slot 18 will be
installed. The EC from the factory will have the factory software and firmware already
installed on the pack. After seating the pack, the EC will synchronize with the existing EC
in slot 1.
Note: If the shelf is equipped with only one EC, skip this procedure.
 Once again verify that both EC circuit packs in the shelf have Part Number (APN) 8DB59241AB.
 Fully seat the EC circuit pack in slot 18. If the NE is equipped with multiple shelves, insert the slot
18 EC on each shelf.
Note: “software mismatch” and “database unsynchronized” alarms will appear.
These alarms will clear after the EC’s are synchronized.
 Wait at least 15 minutes and verify the “software mismatch” and “database unsynchronized” alarms
have cleared.
22
VIII. Set the network element date and time
Purpose
The network element date and time should be initially set manually using the network
element’s internal clock. The network element can later be synchronized with a network
time protocol (NTP) server. This procedure performs the initial setting manually.
1. WebUI procedure :
 Select the Date/Time menu item under Administration.
 The Date/Time provisioning window appears.
 Enter the current date and time and time zone settings and click the “Apply” button.
Note: All current WebUI users will be logged off.
23
2. CLI procedure :
 Type config general date <date> and <Enter>.
Where date is of the format yyyy mm dd.
 Type config general time <time> and <Enter>.
Where time is of the format hh mm ss, and hh is between 0 and 23.
IX. Disable ES port monitoring
Purpose
By default, the ES (Extension Shelf) ports on the EC packs are monitored. This will generate an alarm for
each port that does not have a lan cable connected. Therefore, if the NE does not have any extension
shelves, the EC port monitoring should be disabled.
Note: If the NE has extension shelves installed, this procedure should not be completed.
There is no need to disable the port monitoring.
1. WebUI procedure :
 Expand “Shelf 1” in the equipment tree and then expand each of the EC packs.
 Select an ES port (ES1 or ES2) that is currently in alarm. The ES port provisioning window
will appear.
 Uncheck the Port Enabled checkbox and click “Submit”.
 Repeat the last two steps until all the ES port alarms have cleared.
24
2. CLI procedure :
 Type config interface ec <sh/sl/pt> state down and <Enter>.
Where <sh/sl/pt> is the shelf, slot (1 or 18), and port (ES1 or ES2) of the ES port that is in
alarm.
 Repeat the last step until all the ES alarms have cleared.
X. Update firmware on all circuit packs
Purpose
This procedure will ensure that the latest firmware is uploaded to all the installed circuit packs. This is
done by performing a cold reboot on the NE.
1. WebUI procedure :
 Select the reboot tab from the system view.
 Select the Cold Reboot radio button and click the “Submit” button.
 The following warning message will appear. Click “OK”.
25
 The NE will reboot. The reboot will take several minutes depending on the number of circuit
packs requiring a firmware upgrade.
2. CLI procedure :
 Type config admin resetNE cold and <Enter>.
The following warning message will appear. Type yes and <Enter>.
WARNING: You are about to perform a cold system restart.
This is a service affecting command.
Enter 'yes' to confirm, 'no' to cancel:
 The NE will reboot. The reboot will take several minutes depending on the number of circuit
packs requiring a firmware upgrade.
XI. Configure additional system properties
Purpose
This procedure allows changes to system properties including temperature units and AINS
timer. The AINS timer value is system-wide and will become the default for all ports; the
value can be overridden on each individual port. See the Alcatel-Lucent 1830 Photonic
Service Switch 32/16 (1830 PSS-32/PSS-16) User Provisioning Guide, Equipment
Provisioning for more information on the AINS timer.
26
1. WebUI procedure :
 Select “System” from the tree and the “Details” tab.
 Select or type in the AINS Timer value to use as the system-wide default.
 Select the desired value for the Temperature Units to be used in the system.
 Click the “Submit” button.
2. CLI procedure
 To change the AINS timer value, type config general ainstimer <hours> and <Enter>.
Where <hours> is of the format <hh> [<mm>]. You can also type config general ainstimer
help for the default value and range.
 The temperature unit defaults to Celsius. To change the temperature units to Fahrenheit, type
config admin tempUnits fahrenheit and <Enter>.
27

More Related Content

What's hot

dokumen.tips_ericsson-lte-throughput-troubleshooting-techniquesppt.ppt
dokumen.tips_ericsson-lte-throughput-troubleshooting-techniquesppt.pptdokumen.tips_ericsson-lte-throughput-troubleshooting-techniquesppt.ppt
dokumen.tips_ericsson-lte-throughput-troubleshooting-techniquesppt.ppt
LibaBali
 

What's hot (20)

OpenShift Kubernetes Native Infrastructure for 5GC and Telco Edge Cloud
OpenShift  Kubernetes Native Infrastructure for 5GC and Telco Edge Cloud OpenShift  Kubernetes Native Infrastructure for 5GC and Telco Edge Cloud
OpenShift Kubernetes Native Infrastructure for 5GC and Telco Edge Cloud
 
Vxlan control plane and routing
Vxlan control plane and routingVxlan control plane and routing
Vxlan control plane and routing
 
Juniper mpls best practice part 2
Juniper mpls best practice   part 2Juniper mpls best practice   part 2
Juniper mpls best practice part 2
 
VXLAN BGP EVPN: Technology Building Blocks
VXLAN BGP EVPN: Technology Building BlocksVXLAN BGP EVPN: Technology Building Blocks
VXLAN BGP EVPN: Technology Building Blocks
 
Tr 069
Tr 069Tr 069
Tr 069
 
Cisco router-commands
Cisco router-commandsCisco router-commands
Cisco router-commands
 
ospf routing protocol
ospf routing protocolospf routing protocol
ospf routing protocol
 
Huawei GPON Fundamentals
Huawei GPON FundamentalsHuawei GPON Fundamentals
Huawei GPON Fundamentals
 
HSRP ccna
HSRP ccna HSRP ccna
HSRP ccna
 
Session 1
Session 1Session 1
Session 1
 
MQTT - Protocol for the Internet of Things
MQTT - Protocol for the Internet of ThingsMQTT - Protocol for the Internet of Things
MQTT - Protocol for the Internet of Things
 
Juniper Networks Router Architecture
Juniper Networks Router ArchitectureJuniper Networks Router Architecture
Juniper Networks Router Architecture
 
Implementing cisco mpls
Implementing cisco mplsImplementing cisco mpls
Implementing cisco mpls
 
01 introduction to mpls
01 introduction to mpls 01 introduction to mpls
01 introduction to mpls
 
Ccna
CcnaCcna
Ccna
 
dokumen.tips_ericsson-lte-throughput-troubleshooting-techniquesppt.ppt
dokumen.tips_ericsson-lte-throughput-troubleshooting-techniquesppt.pptdokumen.tips_ericsson-lte-throughput-troubleshooting-techniquesppt.ppt
dokumen.tips_ericsson-lte-throughput-troubleshooting-techniquesppt.ppt
 
Basics of Optical Network Architecture, PON & GPON
Basics of Optical Network Architecture, PON & GPONBasics of Optical Network Architecture, PON & GPON
Basics of Optical Network Architecture, PON & GPON
 
Brkdcn 2035 multi-x
Brkdcn 2035 multi-xBrkdcn 2035 multi-x
Brkdcn 2035 multi-x
 
Access Network Evolution
Access Network Evolution Access Network Evolution
Access Network Evolution
 
3GPP SON Series: Mobility Load Balancing (MLB)
3GPP SON Series: Mobility Load Balancing (MLB)3GPP SON Series: Mobility Load Balancing (MLB)
3GPP SON Series: Mobility Load Balancing (MLB)
 

Viewers also liked (9)

Muhammad_Bilal_cv
Muhammad_Bilal_cvMuhammad_Bilal_cv
Muhammad_Bilal_cv
 
1830 PSS Alcatel Lucent Certificate
1830 PSS Alcatel Lucent Certificate1830 PSS Alcatel Lucent Certificate
1830 PSS Alcatel Lucent Certificate
 
CV2016
CV2016CV2016
CV2016
 
The Capacity Limit of Single-Mode Fibers and Technologies Enabling High Capac...
The Capacity Limit of Single-Mode Fibers and Technologies Enabling High Capac...The Capacity Limit of Single-Mode Fibers and Technologies Enabling High Capac...
The Capacity Limit of Single-Mode Fibers and Technologies Enabling High Capac...
 
Request 100 g webcast presentation-june9_final
Request 100 g webcast presentation-june9_finalRequest 100 g webcast presentation-june9_final
Request 100 g webcast presentation-june9_final
 
Next Generation OTN
Next Generation OTNNext Generation OTN
Next Generation OTN
 
Bgp
BgpBgp
Bgp
 
La 4G pour les nuls - Alcatel Lucent
La 4G pour les nuls - Alcatel LucentLa 4G pour les nuls - Alcatel Lucent
La 4G pour les nuls - Alcatel Lucent
 
OTN for Beginners
OTN for BeginnersOTN for Beginners
OTN for Beginners
 

Similar to Training Alcatel-Lucent WDM PSS 183x

Instalation guide pressto net systemenglish
Instalation guide pressto net systemenglishInstalation guide pressto net systemenglish
Instalation guide pressto net systemenglish
daniellopez972
 
SOP - 2013 Server Build
SOP - 2013 Server BuildSOP - 2013 Server Build
SOP - 2013 Server Build
Robert Jones
 

Similar to Training Alcatel-Lucent WDM PSS 183x (20)

manual vvtk camera_st7501
manual vvtk camera_st7501manual vvtk camera_st7501
manual vvtk camera_st7501
 
CIS 246 Massive Success--snaptutorial.com
CIS 246  Massive Success--snaptutorial.comCIS 246  Massive Success--snaptutorial.com
CIS 246 Massive Success--snaptutorial.com
 
Cis 246 Success Begins / snaptutorial.com
Cis 246 Success Begins / snaptutorial.comCis 246 Success Begins / snaptutorial.com
Cis 246 Success Begins / snaptutorial.com
 
Cis 246 Enthusiastic Study / snaptutorial.com
Cis 246 Enthusiastic Study / snaptutorial.comCis 246 Enthusiastic Study / snaptutorial.com
Cis 246 Enthusiastic Study / snaptutorial.com
 
CIS 246 Technology levels--snaptutorial.com
CIS 246 Technology levels--snaptutorial.comCIS 246 Technology levels--snaptutorial.com
CIS 246 Technology levels--snaptutorial.com
 
installation and configuration of informatica server
installation and configuration of informatica serverinstallation and configuration of informatica server
installation and configuration of informatica server
 
Microsoft Lync Server 2010 Installation
Microsoft Lync Server 2010 InstallationMicrosoft Lync Server 2010 Installation
Microsoft Lync Server 2010 Installation
 
GigaSpaces CCF Quick Tour - 2.3.6
GigaSpaces CCF Quick Tour - 2.3.6GigaSpaces CCF Quick Tour - 2.3.6
GigaSpaces CCF Quick Tour - 2.3.6
 
Merged document
Merged documentMerged document
Merged document
 
How To Upgrade Octopus
How To Upgrade OctopusHow To Upgrade Octopus
How To Upgrade Octopus
 
Instalation guide pressto net systemenglish
Instalation guide pressto net systemenglishInstalation guide pressto net systemenglish
Instalation guide pressto net systemenglish
 
SOP - 2013 Server Build
SOP - 2013 Server BuildSOP - 2013 Server Build
SOP - 2013 Server Build
 
SysInfoTools OpenOffice Calc Recovery
SysInfoTools OpenOffice Calc RecoverySysInfoTools OpenOffice Calc Recovery
SysInfoTools OpenOffice Calc Recovery
 
Cisco vpn
Cisco vpnCisco vpn
Cisco vpn
 
Pangolin User Guide
Pangolin User GuidePangolin User Guide
Pangolin User Guide
 
A Guide to Fix RDP Error when An Internal Error has Occurred.docx
A Guide to Fix RDP Error when An Internal Error has Occurred.docxA Guide to Fix RDP Error when An Internal Error has Occurred.docx
A Guide to Fix RDP Error when An Internal Error has Occurred.docx
 
How to Troubleshoot QuickBooks Error Code 15101.pptx
How to Troubleshoot QuickBooks Error Code 15101.pptxHow to Troubleshoot QuickBooks Error Code 15101.pptx
How to Troubleshoot QuickBooks Error Code 15101.pptx
 
Managing Web Infrastructure Systems with Windows PowerShell 2.0 Demo Script
Managing Web Infrastructure Systems with Windows PowerShell 2.0 Demo ScriptManaging Web Infrastructure Systems with Windows PowerShell 2.0 Demo Script
Managing Web Infrastructure Systems with Windows PowerShell 2.0 Demo Script
 
T hin client configuration
T hin client configurationT hin client configuration
T hin client configuration
 
Install NewGenLib on Windows XP
Install NewGenLib on Windows XPInstall NewGenLib on Windows XP
Install NewGenLib on Windows XP
 

Recently uploaded

Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and Myths
Joaquim Jorge
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Safe Software
 
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
?#DUbAI#??##{{(☎️+971_581248768%)**%*]'#abortion pills for sale in dubai@
 

Recently uploaded (20)

Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and Myths
 
Automating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps ScriptAutomating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps Script
 
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
 
A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?
 
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
 
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdfUnderstanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
 
Artificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyArtificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : Uncertainty
 
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, AdobeApidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of Terraform
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt Robison
 
Top 10 Most Downloaded Games on Play Store in 2024
Top 10 Most Downloaded Games on Play Store in 2024Top 10 Most Downloaded Games on Play Store in 2024
Top 10 Most Downloaded Games on Play Store in 2024
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
 
Manulife - Insurer Innovation Award 2024
Manulife - Insurer Innovation Award 2024Manulife - Insurer Innovation Award 2024
Manulife - Insurer Innovation Award 2024
 
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024
 

Training Alcatel-Lucent WDM PSS 183x

  • 1. 1 CONTENTS I. Stand-alone node set-up.........................................................................................................................2 II. Configure the software environment and load, and commit the software........................................5 1. WebUI procedure:..............................................................................................................................6 2. CLI procedure : ..................................................................................................................................9 III. Set the NE to operate in SDH mode................................................................................................13 1. CLI procedure : ................................................................................................................................13 IV. Set the loopback IP address.............................................................................................................14 1. WebUI procedure :...........................................................................................................................14 2. CLI procedure : ................................................................................................................................14 V. Configure GNE for management system access................................................................................15 1. WebUI procedure :...........................................................................................................................15 2. CLI procedure : ................................................................................................................................18 VI. Complete connection of inventory cables .......................................................................................18 1. WebUI Procedure :...........................................................................................................................18 2. CLI procedure : ................................................................................................................................20 VII. Insert duplicate equipment controller ............................................................................................21 VIII. Set the network element date and time...........................................................................................22 1. WebUI procedure :...........................................................................................................................22 2. CLI procedure : ................................................................................................................................23 IX. Disable ES port monitoring .............................................................................................................23 1. WebUI procedure :...........................................................................................................................23 2. CLI procedure : ................................................................................................................................24 X. Update firmware on all circuit packs .................................................................................................24 1. WebUI procedure :...........................................................................................................................24 2. CLI procedure : ................................................................................................................................25 XI. Configure additional system properties..........................................................................................25 1. WebUI procedure :...........................................................................................................................26 2. CLI procedure ..................................................................................................................................26
  • 2. 2 I. Stand-alone node set-up  Connect one end of the Ethernet cable to the CIT port on the active EC card (indicated by green Active LED) on the master shelf. Connect the other end of the cable to the Ethernet port on your PC.  Open a PC command window and type ipconfig and <Enter>. Verify the IP address assigned by the NE to your PC is 172.16.0.x.  Launch Internet Explorer and enter http://172.16.0.1 in the Address bar. This is the default IP address of the CIT port. Note: Make sure Internet Explorer is not using a proxy server to access this address.  Click Go. The browser connects to the network element and the WebUI login window is displayed.
  • 3. 3  Initialize the database A warning message will indicating that the database is uninitialized.  If the warning message does not appear, this is an indication that there is a database already on the EC. USE:(  Use a telnet application on your PC and open a telnet session connected to the IP address of the CIT port. • The default address for an uncommissioned NE is 172.16.0.1  Hit <Enter> and the login: prompt will appear. Type cli and <Enter>.  Type cli at the Password: prompt and <Enter>.  This starts the CLI, and another Username: prompt will appear. Type admin and <Enter>.  Type config database clear. )  Click “OK” and the system will automatically restart after initialization. A window will appear showing the restart progress.
  • 4. 4  After the restart is complete, the system will prompt you for a new NE name. Type the NE name.  Click the “Submit” button and the system will restart once again. The restart will take approximately 2 minutes.  After the restart is complete, the WebUI will open with the system properties view.
  • 5. 5 II. Configure the software environment and load, and commit the software.  Start the FTP server application on your PC and create a user account. Record the userid and password established for the account.  Establish a root directory for the server and make sure it has read and write privileges. You may create a folder in the root directory that will contain the NE software.  Copy the folder and subfolders with the NE software into the FTP root directory established above. Note: The software folder name to be copied is 1830PSS32-3.0-00. There should also be two subfolders named “1830PSS32” and “1830PSS32M” as well as a CATALOG file.  Open Windows Firewall from the Control Panel.  Select Off. Then click OK.  Open a PC command window and type ipconfig and <Enter>. Once again verify the IP address assigned by the NE to your PC is 172.16.0.x.
  • 6. 6 Important! If this is an Alcatel-Lucent 1830 PSS-16 shelf, use the CLI (command) procedure. 1. WebUI procedure:  Select the Software menu item under Administration and then select FTP Server.  The FTP server settings window appear.
  • 7. 7  Enter NE IP address obtained earlier using ipconfig for the Server IP Address.  Enter the path to the NE software relative to the server root directory in the “Root Directory” field. Note: If the software folder was copied directly into the root directory, enter / in this field.  Enter the UserID and Password to match the account created on the FTP server.  Click the “Apply” button.  Select Administration -> Software -> Upgrade from the top menu.  The Software Upgrade window appears. Note: The software release will be the current factory load.  Select “Audit” from the “Action Type” drop-down list.  Enter the folder name containing the NE software in the “Release Directory” field. The folder name for Release 3.0 should be 1830PSS32-3.0-00.  Click “Apply” and the “Status” field will change to “In Progress”.  Periodically click the “Refresh” button until the “Status” field changes to “Completed”.Verify the “Result” is “Success” and the “Upgrade Path Available” field indicates “Yes”.  Select “Download” for the “Action Type” and click “Apply”. The “Status” field will change to “In Progress”.  Periodically click the “Refresh” button until the “Status” field changes to “Completed”.Verify the “Result” is “Success”.
  • 8. 8  Select “Activate” for the “Action Type” and click “Apply”. The “Status” field will change to “In Progress”. The NE will then reboot, and the WebUI will automatically logout.  Wait about 2 minutes after the fan speed drops back down to normal speed and log back into the NE (typically 10 minutes after activate).  Return to the Software Upgrade window by selecting Administration -> Software -> Upgrade from the top menu. Verify the “Status” field now indicates “Completed”, and verify the “Result” is “Success’.  Select “Commit” for the “Action Type” and click “Apply”. The “Status” field will change to “In Progress”.  Periodically click the “Refresh” button until the “Status” field changes to “Completed”. Verify the “Result” is “Success”.  Verify the Active and Committed releases have changed to the new release.
  • 9. 9 2. CLI procedure :  Use a telnet application on your PC and open a telnet session connected to the IP address of the CIT port. • The default address for an uncommissioned NE is 172.16.0.1  Hit <Enter> and the login: prompt will appear. Type cli and <Enter>.  Type cli at the Password: prompt and <Enter>.  This starts the CLI, and another Username: prompt will appear. Type admin and <Enter>.  Type config software server ip <ip> and <Enter>. Where <ip> is the ip address of the PC with the FTP server. This is the same ip address obtained using the ipconfig command in the PC command window.  Type config software server userid <userid> and <Enter>. Where <userid> is the user_id for the user account defined on the FTP server.  Type <pw> and <Enter>. Where <pw> is the password for the user account defined on the FTP server.  Type config software server root <path> and <Enter>. Where <path> is the path to the NE software relative to the server root directory. Note: If the software folder was copied directly into the root directory, enter / for the <path>.  Type config software server detail and <Enter>. Sample output below. Software Server Protocol : FTP Software Server IP : 172.16.0.2 Software Server Userid : sw1 Software Server Root Directory : /  Verify the server settings are correct.  Type config software upgrade status and <Enter>.
  • 10. 10 Sample output below. Software Upgrade Information: Software Server IP : 172.16.0.2 Software Server Root Directory : / Committed Release : Working Release Directory : Working Release : 1830PSS32-0.00-7 Active Release : 1830PSS32-0.00-7/ Operation : Operation Status : Upgrade Path Available : True Software Download Script (Timezone: ):  Verify the current active software is an older release than software you are loading.  Type config software upgrade manual audit <releasedir> nobackup and <Enter>. Where <releasedir> is the directory name on the PC containing the software. The folder name for Release 3.0 should be 1830PSS32-3.0-00.  Type config software upgrade status and <Enter>. A listing of packs will be displayed along with the status showing which packs need to be upgraded. Sample output below. Software Upgrade Information: Software Server IP : 172.16.0.2 Software Server Root Directory : /SVT/ Committed Release : Working Release Directory : 1830PSS32-0.00-7/ Working Release : 1830PSS32-0.00-7 Active Release : 1830PSS32-0.00-7 Operation : Audit Operation Status : Completed Upgrade Path Available : True Software Download Script (Timezone: ): Stage=0 Step=1 SH/SL: 1/1 CARDTYPE: EC ACTION: Audit node Completed 100% complete
  • 11. 11 RESULT: Success Stage=1 Step=0 SH/SL: 0/0 CARDTYPE: Empty ACTION: Transfer to disk Planned 0% complete RESULT: None Stage=2 Step=0 SH/SL: 1/1 CARDTYPE: EC ACTION: Activate Planned 0% complete RESULT: None Stage=3 Step=0 SH/SL: 1/2 CARDTYPE: AHPHG ACTION: Activate Planned 0% complete RESULT: None Stage=3 Step=1 SH/SL: 1/3 CARDTYPE: CWR8 ACTION: Activate Planned 0% complete RESULT: None Stage=3 Step=2 SH/SL: 1/7 CARDTYPE: 11STAR1 ACTION: Activate Planned 0% complete RESULT: None Stage=3 Step=3 SH/SL: 1/13 CARDTYPE: 11STAR1 ACTION: Activate Planned 0% complete RESULT: None Stage=3 Step=5 SH/SL: 1/15 CARDTYPE: CWR8 ACTION: Activate Planned 0% complete RESULT: None Stage=3 Step=6 SH/SL: 1/17 CARDTYPE: ALPHG ACTION: Activate Planned 0% complete RESULT: None  Repeat config software upgrade status until the Operation Status indicates Completed. Verify the Upgrade Path Available changes to True.  Type config software upgrade manual load and <Enter>. This will transfer the software to the NE.  Type config software upgrade status and <Enter>. Watch for the following lines. ... Operation : Load Operation Status : In Progress 0% ...  Continue to execute the status command until the Operation Status shows Completed.
  • 12. 12  Type config software upgrade manual activate and <Enter>. This will activate the software on the EC card.  The NE will reboot and the telnet connection will drop. Wait about 2 minutes after the fan speed drops back to normal speed and log back into the NE (typically 10 minutes after activate). Then Connect to the NE for CLI access.  Type config software upgrade status and <Enter>.Watch for the following lines. ... Operation : Activate Operation Status : In Progress 0% ...  Continue to execute the status command until the Operation Status shows Completed. Note: The output will also display the progress of the activation on each of the packs in the NE. The Operation Status will not show completed until all packs have been activated on the new release.  Type config software upgrade commit and <Enter>. This will commit the software to be the primary release.  Type config software upgrade status and <Enter>. Watch for the following lines. ... Operation : Commit Operation Status : In Progress 0% ...  Continue to execute the status command until the Operation Status shows Completed.  After the last status command is executed, verify the new software release is displayed as the committed, working and active release. See the sample output below. Software Upgrade Information: Software Server IP : 172.16.0.2 Software Server Root Directory : / Committed Release : 1830PSS32-3.0-00 Working Release Directory : 1830PSS32-3.0-00/ Working Release : 1830PSS32-3.0-00 Active Release : 1830PSS32-3.0-00/ Operation : Commit Operation Status : Completed Upgrade Path Available : False Software Download Script (Timezone: ):
  • 13. 13  NOTE : If this is an Alcatel-Lucent 1830 PSS-16 shelf, the following command is required to bring the node up as an Alcatel-Lucent 1830 PSS-16.  Type config database clear and <Enter>. The shelf will reboot and when the reboot completes the shelf will be correctly configured as an Alcatel-Lucent 1830 PSS-16 shelf. III. Set the NE to operate in SDH mode Background The NE defaults to SONET mode. You need to perform this procedure only if you want the NE to operate in SDH mode. NOTICE This procedure should only be executed when a system is first turned up. 1. CLI procedure :  Type show version and <Enter>. Sample output: Software Version: 1830PSS32-3.0-00  Copy the string after “Software Version”. This will be used as the password for the SDH mode command.  Type config admin mode sdh <pw> and <Enter>. Where <pw> is the password copied in the previous step.  The following warning will appear. WARNING: Changing the SONET/SDH mode will cause the database to be cleared, the node to be cold reset and all services to be deleted.  Type yes and <Enter>. You will be logged out. This procedure is complete.
  • 14. 14 IV. Set the loopback IP address 1. WebUI procedure :  Select “System” from the tree and the “Details” tab.  At the “Loopback IP Address” field, enter the IP address designated in the site documentation.  At the “Loopback Subnet Mask” field, enter the subnet mask designated in the site documentation.  Click the “Submit” button.  Click “OK.” The system will reboot, and WebUI will automatically logout.  Wait for the system to reboot (watch for the CIT link light to turn green) and log back into the WebUI. 2. CLI procedure :  Type config interface loop ip <address>/<mask> and <Enter>. Where <address> is the IP address and <mask> represents the subnet mask following the CIDR format. Obtain this information from the site documentation.
  • 15. 15  The following warning message will appear. WARNING: Changing the loopback IP address will result in a warm reset of this network element. Enter 'yes' to confirm, 'no' to cancel:  Type yes and <Enter>. The CLI session will be terminated. V. Configure GNE for management system access Purpose This procedure will provision and enable the OAMP port so that the NE can act as a Gateway Network Element. The procedure will also provision the IP route information to allow connection to RNEs. Not all NEs (i.e. RNEs) require this provisioning. Refer to the site documentation. 1. WebUI procedure :  Expand “Shelf 1” in the equipment tree and then expand “slot 40: USRPNL” (slot 10 for PSS-16).  Select OAMP. The OAMP port provisioning window will appear.
  • 16. 16  Enter the IP address and subnet mask as indicated in the site documentation.  Check the Port Enabled checkbox.  Click the “Submit” button.  Select Administration -> Networking -> IP Routes from the top menu.  The IP Routes screen is displayed.  Click the “Create” button. The Create IP Routes screen is displayed.
  • 17. 17  Enter the parameters based on the site documentation.  Click the “Apply” button.  Verify the new IP route is now shown in the IP routes.
  • 18. 18 2. CLI procedure :  Type config interface usrpnl oamp ip <address>/<mask> and <Enter>. Where <address> is the IP address and <mask> represents the subnet mask following the CIDR format. Obtain this information from the site documentation.  Type config interface usrpnl oamp state up and <Enter>.  Type config cn routes default add <address> and <Enter>. Where <address> is the gateway address from the site documentation  Type config interface usrpnl oamp rou en and <Enter>. VI. Complete connection of inventory cables Purpose The inventory cables will be connected and DCM, SFD44, SFD44B, and ITLB units discovered in this procedure following the site documentation. Note: If the DCM, SFD44, SFD44B, and ITLB shelf numbering contains non contiguous numbers (numbers are skipped), the shelves must be manually pre- provisioned before the inventory cables are connected. This procedure takes care of that case. 1. WebUI Procedure :  Observe the equipment tree in the left window of the system view and verify there are no shelves numbered 25 or greater.
  • 19. 19  Refer to the site documentation to determine the shelf numbering of the DCM, SFD44, SFD44B, and ITLB units. List them in order starting with 25.  Does the shelf numbering contain non contiguous numbers (numbers are skipped)? If yes, skip to steps between two (). If no, continue.  Determine the next sequential DCM, SFD44, SFD44B, or ITLB unit that has not been discovered and connect the inventory cable to that unit.  Wait 2 minutes and click the refresh button (the double arrows located at the top of the equipment tree).  The new shelf should appear in the tree with the appropriate shelf number. If not, repeat clicking refresh If the shelf still does not appear, check the cable connection or replace the inventory cable.  Are there additional DCM, SFD44, SFD44B, or ITLB units to be discovered? If yes, repeat the last 3 steps. If no, end of steps.  () In the System view, select the “Create Shelf” tab. The Create Shelf view will appear.  Enter the appropriate provisioned type and shelf ID number of the next DCM, SFD44, SFD44B, or ITLB shelf to be added. Enter additional parameters as required, then click the “Apply” button.  Repeat until all the DCM, SFD44, SFD44B, and ITLB shelves have been created.  Close the create shelf window and verify all the DCM, SFD44, SFD44B, and ITLB shelves now appear correctly in the equipment tree.
  • 20. 20  Connect the inventory cables to all the DCM, SFD44, SFD44B, and ITLB units.  Check the alarms on the system and verify there are no equipment alarms related to the DCM, SFD44, SFD44B, or ITLB shelves. () 2. CLI procedure :  Type show shelf * and <Enter>. Sample output. Shelf 1 Information Name : Master Shelf Description : Master Shelf ExpectedAmps : 30 Programmed Type : Universal Shelf Present Type : Universal Shelf  Verify there are no shelves number 25 or greater.  Refer to the site documentation to determine the shelf numbering of the DCM, SFD44, SFD44B, and ITLB units. List them in order starting with 25.  Does the shelf numbering contain non contiguous numbers (numbers are skipped)? If yes, skip to steps between two (). If no, continue.  Determine the next sequential DCM, SFD44, SFD44B, or ITLB unit that has not been discovered and connect the inventory cable to that unit.  Wait 2 minutes and type show shelf * and <Enter>.  The new shelf should be listed in the output with the appropriate shelf number. If not, repeat show shelf. If the shelf still does not appear, check the cable connection or replace the inventory cable.  Are there additional DCM, SFD44, SFD44B, or ITLB units to be discovered? If yes, repeat the last 3 steps. If no, end of steps.
  • 21. 21  ()Type config shelf <shelf> type <type> and <Enter>. Where <shelf> is the shelf number of the next shelf to be created and <type> is either dcm, sfd44, sfd44b, or itlb.  Repeat this step until all the DCM, SFD44, SFD44B, and ITLB shelves have been created.  Type show shelf * and <Enter>.  Verify all the shelves that were created are now listed correctly.  Connect the inventory cables to all the DCM, SFD44, SFD44B, and ITLB units.  Type alm and <Enter>.  Verify there are no equipment alarms related to the DCM, SFD44, SFD44B, or ITLB shelves. () VII. Insert duplicate equipment controller Purpose In this procedure, the duplicate Equipment Controller (EC), if equipped, in slot 18 will be installed. The EC from the factory will have the factory software and firmware already installed on the pack. After seating the pack, the EC will synchronize with the existing EC in slot 1. Note: If the shelf is equipped with only one EC, skip this procedure.  Once again verify that both EC circuit packs in the shelf have Part Number (APN) 8DB59241AB.  Fully seat the EC circuit pack in slot 18. If the NE is equipped with multiple shelves, insert the slot 18 EC on each shelf. Note: “software mismatch” and “database unsynchronized” alarms will appear. These alarms will clear after the EC’s are synchronized.  Wait at least 15 minutes and verify the “software mismatch” and “database unsynchronized” alarms have cleared.
  • 22. 22 VIII. Set the network element date and time Purpose The network element date and time should be initially set manually using the network element’s internal clock. The network element can later be synchronized with a network time protocol (NTP) server. This procedure performs the initial setting manually. 1. WebUI procedure :  Select the Date/Time menu item under Administration.  The Date/Time provisioning window appears.  Enter the current date and time and time zone settings and click the “Apply” button. Note: All current WebUI users will be logged off.
  • 23. 23 2. CLI procedure :  Type config general date <date> and <Enter>. Where date is of the format yyyy mm dd.  Type config general time <time> and <Enter>. Where time is of the format hh mm ss, and hh is between 0 and 23. IX. Disable ES port monitoring Purpose By default, the ES (Extension Shelf) ports on the EC packs are monitored. This will generate an alarm for each port that does not have a lan cable connected. Therefore, if the NE does not have any extension shelves, the EC port monitoring should be disabled. Note: If the NE has extension shelves installed, this procedure should not be completed. There is no need to disable the port monitoring. 1. WebUI procedure :  Expand “Shelf 1” in the equipment tree and then expand each of the EC packs.  Select an ES port (ES1 or ES2) that is currently in alarm. The ES port provisioning window will appear.  Uncheck the Port Enabled checkbox and click “Submit”.  Repeat the last two steps until all the ES port alarms have cleared.
  • 24. 24 2. CLI procedure :  Type config interface ec <sh/sl/pt> state down and <Enter>. Where <sh/sl/pt> is the shelf, slot (1 or 18), and port (ES1 or ES2) of the ES port that is in alarm.  Repeat the last step until all the ES alarms have cleared. X. Update firmware on all circuit packs Purpose This procedure will ensure that the latest firmware is uploaded to all the installed circuit packs. This is done by performing a cold reboot on the NE. 1. WebUI procedure :  Select the reboot tab from the system view.  Select the Cold Reboot radio button and click the “Submit” button.  The following warning message will appear. Click “OK”.
  • 25. 25  The NE will reboot. The reboot will take several minutes depending on the number of circuit packs requiring a firmware upgrade. 2. CLI procedure :  Type config admin resetNE cold and <Enter>. The following warning message will appear. Type yes and <Enter>. WARNING: You are about to perform a cold system restart. This is a service affecting command. Enter 'yes' to confirm, 'no' to cancel:  The NE will reboot. The reboot will take several minutes depending on the number of circuit packs requiring a firmware upgrade. XI. Configure additional system properties Purpose This procedure allows changes to system properties including temperature units and AINS timer. The AINS timer value is system-wide and will become the default for all ports; the value can be overridden on each individual port. See the Alcatel-Lucent 1830 Photonic Service Switch 32/16 (1830 PSS-32/PSS-16) User Provisioning Guide, Equipment Provisioning for more information on the AINS timer.
  • 26. 26 1. WebUI procedure :  Select “System” from the tree and the “Details” tab.  Select or type in the AINS Timer value to use as the system-wide default.  Select the desired value for the Temperature Units to be used in the system.  Click the “Submit” button. 2. CLI procedure  To change the AINS timer value, type config general ainstimer <hours> and <Enter>. Where <hours> is of the format <hh> [<mm>]. You can also type config general ainstimer help for the default value and range.  The temperature unit defaults to Celsius. To change the temperature units to Fahrenheit, type config admin tempUnits fahrenheit and <Enter>.
  • 27. 27