SlideShare a Scribd company logo
1 of 22
EMI Analyst™
EMI ANALYST™ Software Suite
I n t u i t i v e  A c c u r a t e  E f f e c t i v e
Radiated susceptibility analysis
overview
EMI Analyst™EMI Analyst™
EMI Analyst™ is a 4-in-1 EMI Analysis Tool
EMI Analyst™ calculates electromagnetic interference for cable-
connected circuits
• Conducted Emissions – CE Analyst™
– AF and RF current and voltage emitted on cables
• Conducted Susceptibility – CS Analyst™
– Current and voltage induced by interference injected on or coupled to cabling
• Radiated Emissions – RE Analyst™
– Electric and magnetic fields emitted by cables
• Radiated Susceptibility – RS Analyst™
– Current and voltage induced by electromagnetic fields on cable
EMI Analyst™EMI Analyst™
What does RS Analyst™ do?
Calculates current and voltage induced on cabling and
end circuits by external electromagnetic fields
EMI Analyst™EMI Analyst™
EMI Analyst™ Covers All Radiated Susceptibility
Test Specifications
Simulates RS test setups for most EMI test configurations
– Consumer
– Industrial
– Aviation
– Automotive
– Military and Space
EMI Analyst™EMI Analyst™
Consumer and Industrial Electronics
• Radiated Immunity
Test Setup
• EN61000-4-3
– Edition 1, 2, 3
– Non-conductive table
– 1, 3, 10, 20, 30 V/m
– 1 m or 3 m test distance
– 80 MHz – 6 GHz
EMI Analyst™EMI Analyst™
Commercial Aircraft Electronics
• RF Radiated Susceptibility
Test Setup
• RTCA/DO-160G
– rev. D, E, F, G
– Copper test bench
– 1 V/m to 7000 V/m
– 1 m test distance
– 100 MHz to 18 GHz
EMI Analyst™EMI Analyst™
Automotive Electronics
• Radiated Immunity (ALSE)
Test Setup
(absorber lined shielded enclosure)
• ISO 11452-2
– 2nd Edition
– Copper test bench
– 25 V/m to 100+ V/m
– 1 m test distance
– 80 MHz to 4.2+ GHz
EMI Analyst™EMI Analyst™
Military and Space Electronics
• Radiated Susceptibility
Test Setup
• MIL-STD-461G RS03, RS103
– rev. C, D, E, F, G
– Copper test bench
– 5 V/m to 200+ V/m
– 1 m test distance
– 10 kHz to 40 GHz
EMI Analyst™EMI Analyst™
What Information is Needed?
Before you start the analysis,
collect
– Frequency Range
– Field Level
– Field direction, polarization
– Cabling configuration
– End Circuits
– Pass/Fail Criteria
(susceptibility threshold)
EMI Analyst™EMI Analyst™
Switch Mode Power Converter
– MIL-STD-461F, RS103 tailored
Radiated Susceptibility Example
Block
Diagram
Circuit
Schematic
Switch Mode
Power
Converter
EMI Filter Cable Conductors
LISNs
and
DC Power
Supply
StrayC
4.7uH
1uF 3.3uF
0.1uF
0.1uF
10 uH
10 uH
330 nF
10 nF
10 nF
100 uH
PS
Power Converter EMI Filter Cable Conductors LISNs and DC PS
Frequency Range
2 MHz – 18 GHz
Field Level
5 – 50 V/m
Field direction, polar.
Broadside, vertical
Cabling configuration
Unshielded wire pair
over ground plane
End Circuits
(L) EMI filter
(R) LISN & PS
Pass/Fail Criteria
100 mV  1 GHz
1 V > 1 GHz
EMI Analyst™EMI Analyst™
Frequency Range
• Start & Stop Frequency
• Scale: Log or Linear
• Resolution
– Pts / Decade for Log Scale
– Hz for Linear Scale
• Example: MIL-STD-461F
– Freq: 2 MHz – 18 GHz
– Scale: Log
– Res: 100 pts / dec
• 48 ppd, 2 MHz – 30 MHz
• 462 ppd, 30 MHz – 1 GHz
• 924 ppd, 1 GHz to 40 GHz
HELP: file:///C:/Program%20Files%20(x86)/EMI%20Software/Help/NetHelp/EMI_Analyst_Help.htm#!modules/5/documents/frequency.htm
EMI Analyst™EMI Analyst™
Field Level
• Field strength to which cables
are exposed
– E-field
– Far field source
• Frequency/Amplitude Pairs
– Enter in table
– Load/Save to template library
– Automatically graphed
HELP: file:///C:/Program%20Files%20(x86)/EMI%20Software/Help/NetHelp/EMI_Analyst_Help.htm#!modules/5/documents/limit1.htm
EMI Analyst™EMI Analyst™
Field Polarization and Direction
• Presets
– All RS tests are Broadside
– Most specs require vertical and
horizontal polarization
– Broadside, vertical usually worst
case
• Edit values
– Numeric entry
– Rotate – click + drag
• Edit appearance
– Zoom – Ctrl + drag
– Move – Shift + drag
HELP: file:///C:/Program%20Files%20(x86)/EMI%20Software/Help/NetHelp/EMI_Analyst_Help.htm#!modules/5/documents/fielddirection.htm
EMI Analyst™EMI Analyst™
Cabling Configuration
• 8 built-in templates
– 4 shielded, 4 unshielded
• Input
– Physical dimensions
– Conductor and dielectric
materials
• Computes
– Characteristic impedance
– R, L, C, G values
HELP: file:///C:/Program%20Files%20(x86)/EMI%20Software/Help/NetHelp/EMI_Analyst_Help.htm#!modules/5/documents/conductors1.htm
EMI Analyst™EMI Analyst™
End Circuits
• Schematic capture
– Ladder network
– Passive components (R, L, C,
and magnetically coupled)
• Left-End
– EMI filter for PS circuit
• Right-End
– LISN circuit
HELP: file:///C:/Program%20Files%20(x86)/EMI%20Software/Help/NetHelp/EMI_Analyst_Help.htm#!modules/5/documents/schematic.htm
EMI Analyst™EMI Analyst™
Left-End Circuit: EMI Filter
4.7uH
1uF 3.3uF
0.1uF
0.1uF
10 uH
10 uH
330 nF
10 nF
10 nF
100 uH
Input Power Filter Schematic
EMI Analyst™ Filter Schematic
EMI Analyst™EMI Analyst™
Right-End Circuit: LISN and DC Power Supply
LISN schematic
EMI Analyst™ LISN schematic
and power supply impedance
EMI Analyst™EMI Analyst™
Analysis Results – Conductors
• Voltage and current induced on cable conductors
EMI Analyst™EMI Analyst™
Analysis Results – Animated
• Input Z, DM and CM
EMI Analyst™EMI Analyst™
Analysis Results – 3D
• Rotate – Click + drag
• Zoom – Ctrl + drag
• Move – Shift + drag
Shown: Current on
Wire 1
EMI Analyst™EMI Analyst™
Analysis Results – Left End
• Induced DM voltage inboard of filtering
V
4.7uH
1uF 3.3uF
0.1uF
0.1uF
10 uH
10 uH
330 nF
10 nF
10 nF
100 uH
867 mV max.
Pass/Fail Criteria:
100 mV  1 GHz, 1 V > 1 GHz
EMI Analyst™EMI Analyst™
Learn More
For more information about RS Analyst™ and the other three
applications that make up the EMI Analyst™, visit
http://emisoftware.com.

More Related Content

Viewers also liked

Nosocomial Infection
Nosocomial InfectionNosocomial Infection
Nosocomial Infection
Zahoor Ahmed
 

Viewers also liked (8)

Bio263 Lecture 2: Becoming human
Bio263 Lecture 2: Becoming humanBio263 Lecture 2: Becoming human
Bio263 Lecture 2: Becoming human
 
Susceptibility Weighted Imaging (SWI)
Susceptibility Weighted Imaging (SWI)Susceptibility Weighted Imaging (SWI)
Susceptibility Weighted Imaging (SWI)
 
Using EMI Analyst™ to Perform Method CS114 Analyses for MIL-STD-461
Using EMI Analyst™ to Perform Method CS114 Analyses for MIL-STD-461Using EMI Analyst™ to Perform Method CS114 Analyses for MIL-STD-461
Using EMI Analyst™ to Perform Method CS114 Analyses for MIL-STD-461
 
Role of the Laboratory in Antimicrobial Resistance Data
Role of the Laboratory in Antimicrobial Resistance DataRole of the Laboratory in Antimicrobial Resistance Data
Role of the Laboratory in Antimicrobial Resistance Data
 
Open Education and the Future - TEDxNYED
Open Education and the Future - TEDxNYEDOpen Education and the Future - TEDxNYED
Open Education and the Future - TEDxNYED
 
Health Communication
Health CommunicationHealth Communication
Health Communication
 
CONCEPT OF DISEASE
CONCEPT OF DISEASECONCEPT OF DISEASE
CONCEPT OF DISEASE
 
Nosocomial Infection
Nosocomial InfectionNosocomial Infection
Nosocomial Infection
 

Recently uploaded

Digital Communication Essentials: DPCM, DM, and ADM .pptx
Digital Communication Essentials: DPCM, DM, and ADM .pptxDigital Communication Essentials: DPCM, DM, and ADM .pptx
Digital Communication Essentials: DPCM, DM, and ADM .pptx
pritamlangde
 
DeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakesDeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakes
MayuraD1
 

Recently uploaded (20)

UNIT 4 PTRP final Convergence in probability.pptx
UNIT 4 PTRP final Convergence in probability.pptxUNIT 4 PTRP final Convergence in probability.pptx
UNIT 4 PTRP final Convergence in probability.pptx
 
Introduction to Data Visualization,Matplotlib.pdf
Introduction to Data Visualization,Matplotlib.pdfIntroduction to Data Visualization,Matplotlib.pdf
Introduction to Data Visualization,Matplotlib.pdf
 
School management system project Report.pdf
School management system project Report.pdfSchool management system project Report.pdf
School management system project Report.pdf
 
AIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech studentsAIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech students
 
Computer Graphics Introduction To Curves
Computer Graphics Introduction To CurvesComputer Graphics Introduction To Curves
Computer Graphics Introduction To Curves
 
Theory of Time 2024 (Universal Theory for Everything)
Theory of Time 2024 (Universal Theory for Everything)Theory of Time 2024 (Universal Theory for Everything)
Theory of Time 2024 (Universal Theory for Everything)
 
Digital Communication Essentials: DPCM, DM, and ADM .pptx
Digital Communication Essentials: DPCM, DM, and ADM .pptxDigital Communication Essentials: DPCM, DM, and ADM .pptx
Digital Communication Essentials: DPCM, DM, and ADM .pptx
 
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
 
Computer Networks Basics of Network Devices
Computer Networks  Basics of Network DevicesComputer Networks  Basics of Network Devices
Computer Networks Basics of Network Devices
 
Unit 4_Part 1 CSE2001 Exception Handling and Function Template and Class Temp...
Unit 4_Part 1 CSE2001 Exception Handling and Function Template and Class Temp...Unit 4_Part 1 CSE2001 Exception Handling and Function Template and Class Temp...
Unit 4_Part 1 CSE2001 Exception Handling and Function Template and Class Temp...
 
Hostel management system project report..pdf
Hostel management system project report..pdfHostel management system project report..pdf
Hostel management system project report..pdf
 
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
COST-EFFETIVE  and Energy Efficient BUILDINGS ptxCOST-EFFETIVE  and Energy Efficient BUILDINGS ptx
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
 
DC MACHINE-Motoring and generation, Armature circuit equation
DC MACHINE-Motoring and generation, Armature circuit equationDC MACHINE-Motoring and generation, Armature circuit equation
DC MACHINE-Motoring and generation, Armature circuit equation
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
 
💚Trustworthy Call Girls Pune Call Girls Service Just Call 🍑👄6378878445 🍑👄 Top...
💚Trustworthy Call Girls Pune Call Girls Service Just Call 🍑👄6378878445 🍑👄 Top...💚Trustworthy Call Girls Pune Call Girls Service Just Call 🍑👄6378878445 🍑👄 Top...
💚Trustworthy Call Girls Pune Call Girls Service Just Call 🍑👄6378878445 🍑👄 Top...
 
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptxS1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
 
Ground Improvement Technique: Earth Reinforcement
Ground Improvement Technique: Earth ReinforcementGround Improvement Technique: Earth Reinforcement
Ground Improvement Technique: Earth Reinforcement
 
DeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakesDeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakes
 
Max. shear stress theory-Maximum Shear Stress Theory ​ Maximum Distortional ...
Max. shear stress theory-Maximum Shear Stress Theory ​  Maximum Distortional ...Max. shear stress theory-Maximum Shear Stress Theory ​  Maximum Distortional ...
Max. shear stress theory-Maximum Shear Stress Theory ​ Maximum Distortional ...
 
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
 

Radiated Susceptibility Analysis Software; RS Analyst Overview

  • 1. EMI Analyst™ EMI ANALYST™ Software Suite I n t u i t i v e  A c c u r a t e  E f f e c t i v e Radiated susceptibility analysis overview
  • 2. EMI Analyst™EMI Analyst™ EMI Analyst™ is a 4-in-1 EMI Analysis Tool EMI Analyst™ calculates electromagnetic interference for cable- connected circuits • Conducted Emissions – CE Analyst™ – AF and RF current and voltage emitted on cables • Conducted Susceptibility – CS Analyst™ – Current and voltage induced by interference injected on or coupled to cabling • Radiated Emissions – RE Analyst™ – Electric and magnetic fields emitted by cables • Radiated Susceptibility – RS Analyst™ – Current and voltage induced by electromagnetic fields on cable
  • 3. EMI Analyst™EMI Analyst™ What does RS Analyst™ do? Calculates current and voltage induced on cabling and end circuits by external electromagnetic fields
  • 4. EMI Analyst™EMI Analyst™ EMI Analyst™ Covers All Radiated Susceptibility Test Specifications Simulates RS test setups for most EMI test configurations – Consumer – Industrial – Aviation – Automotive – Military and Space
  • 5. EMI Analyst™EMI Analyst™ Consumer and Industrial Electronics • Radiated Immunity Test Setup • EN61000-4-3 – Edition 1, 2, 3 – Non-conductive table – 1, 3, 10, 20, 30 V/m – 1 m or 3 m test distance – 80 MHz – 6 GHz
  • 6. EMI Analyst™EMI Analyst™ Commercial Aircraft Electronics • RF Radiated Susceptibility Test Setup • RTCA/DO-160G – rev. D, E, F, G – Copper test bench – 1 V/m to 7000 V/m – 1 m test distance – 100 MHz to 18 GHz
  • 7. EMI Analyst™EMI Analyst™ Automotive Electronics • Radiated Immunity (ALSE) Test Setup (absorber lined shielded enclosure) • ISO 11452-2 – 2nd Edition – Copper test bench – 25 V/m to 100+ V/m – 1 m test distance – 80 MHz to 4.2+ GHz
  • 8. EMI Analyst™EMI Analyst™ Military and Space Electronics • Radiated Susceptibility Test Setup • MIL-STD-461G RS03, RS103 – rev. C, D, E, F, G – Copper test bench – 5 V/m to 200+ V/m – 1 m test distance – 10 kHz to 40 GHz
  • 9. EMI Analyst™EMI Analyst™ What Information is Needed? Before you start the analysis, collect – Frequency Range – Field Level – Field direction, polarization – Cabling configuration – End Circuits – Pass/Fail Criteria (susceptibility threshold)
  • 10. EMI Analyst™EMI Analyst™ Switch Mode Power Converter – MIL-STD-461F, RS103 tailored Radiated Susceptibility Example Block Diagram Circuit Schematic Switch Mode Power Converter EMI Filter Cable Conductors LISNs and DC Power Supply StrayC 4.7uH 1uF 3.3uF 0.1uF 0.1uF 10 uH 10 uH 330 nF 10 nF 10 nF 100 uH PS Power Converter EMI Filter Cable Conductors LISNs and DC PS Frequency Range 2 MHz – 18 GHz Field Level 5 – 50 V/m Field direction, polar. Broadside, vertical Cabling configuration Unshielded wire pair over ground plane End Circuits (L) EMI filter (R) LISN & PS Pass/Fail Criteria 100 mV  1 GHz 1 V > 1 GHz
  • 11. EMI Analyst™EMI Analyst™ Frequency Range • Start & Stop Frequency • Scale: Log or Linear • Resolution – Pts / Decade for Log Scale – Hz for Linear Scale • Example: MIL-STD-461F – Freq: 2 MHz – 18 GHz – Scale: Log – Res: 100 pts / dec • 48 ppd, 2 MHz – 30 MHz • 462 ppd, 30 MHz – 1 GHz • 924 ppd, 1 GHz to 40 GHz HELP: file:///C:/Program%20Files%20(x86)/EMI%20Software/Help/NetHelp/EMI_Analyst_Help.htm#!modules/5/documents/frequency.htm
  • 12. EMI Analyst™EMI Analyst™ Field Level • Field strength to which cables are exposed – E-field – Far field source • Frequency/Amplitude Pairs – Enter in table – Load/Save to template library – Automatically graphed HELP: file:///C:/Program%20Files%20(x86)/EMI%20Software/Help/NetHelp/EMI_Analyst_Help.htm#!modules/5/documents/limit1.htm
  • 13. EMI Analyst™EMI Analyst™ Field Polarization and Direction • Presets – All RS tests are Broadside – Most specs require vertical and horizontal polarization – Broadside, vertical usually worst case • Edit values – Numeric entry – Rotate – click + drag • Edit appearance – Zoom – Ctrl + drag – Move – Shift + drag HELP: file:///C:/Program%20Files%20(x86)/EMI%20Software/Help/NetHelp/EMI_Analyst_Help.htm#!modules/5/documents/fielddirection.htm
  • 14. EMI Analyst™EMI Analyst™ Cabling Configuration • 8 built-in templates – 4 shielded, 4 unshielded • Input – Physical dimensions – Conductor and dielectric materials • Computes – Characteristic impedance – R, L, C, G values HELP: file:///C:/Program%20Files%20(x86)/EMI%20Software/Help/NetHelp/EMI_Analyst_Help.htm#!modules/5/documents/conductors1.htm
  • 15. EMI Analyst™EMI Analyst™ End Circuits • Schematic capture – Ladder network – Passive components (R, L, C, and magnetically coupled) • Left-End – EMI filter for PS circuit • Right-End – LISN circuit HELP: file:///C:/Program%20Files%20(x86)/EMI%20Software/Help/NetHelp/EMI_Analyst_Help.htm#!modules/5/documents/schematic.htm
  • 16. EMI Analyst™EMI Analyst™ Left-End Circuit: EMI Filter 4.7uH 1uF 3.3uF 0.1uF 0.1uF 10 uH 10 uH 330 nF 10 nF 10 nF 100 uH Input Power Filter Schematic EMI Analyst™ Filter Schematic
  • 17. EMI Analyst™EMI Analyst™ Right-End Circuit: LISN and DC Power Supply LISN schematic EMI Analyst™ LISN schematic and power supply impedance
  • 18. EMI Analyst™EMI Analyst™ Analysis Results – Conductors • Voltage and current induced on cable conductors
  • 19. EMI Analyst™EMI Analyst™ Analysis Results – Animated • Input Z, DM and CM
  • 20. EMI Analyst™EMI Analyst™ Analysis Results – 3D • Rotate – Click + drag • Zoom – Ctrl + drag • Move – Shift + drag Shown: Current on Wire 1
  • 21. EMI Analyst™EMI Analyst™ Analysis Results – Left End • Induced DM voltage inboard of filtering V 4.7uH 1uF 3.3uF 0.1uF 0.1uF 10 uH 10 uH 330 nF 10 nF 10 nF 100 uH 867 mV max. Pass/Fail Criteria: 100 mV  1 GHz, 1 V > 1 GHz
  • 22. EMI Analyst™EMI Analyst™ Learn More For more information about RS Analyst™ and the other three applications that make up the EMI Analyst™, visit http://emisoftware.com.

Editor's Notes

  1. What is EMI Analyst?