  • 1. + HT-2 / 9600 Series Spa Control Dealer Guidehttp://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
  • 2. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
  • 3. HT-2 / 9600 Series Control ContentsSpa Control • Description • Features • HT-2 Spaside ControlConnection • Spaside to System Circuit Board • Spaside to external ReceptacleInstructions • Pump 1 Key • Pump 2 Key • Light Key • Temperature Set Keys • Heater Auto Start • Temperature Display • Filter Cycles (Start Time) • Filter Cycles (Duration) • Economy Mode (Start Time) • Economy Mode (Duration) Alarms • Freeze Protection • High Temperature • Pressure Switch • Temperature Sensor • High-Limit Temperature Sensor • Economy Mode • Smart Winter Mode • Power FailureProgramming • Low Level ProgrammingInternal Wiring • Wiring Diagram http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
  • 4. HT-2 / 9600 Series Control Spa ControlDescription The Ultimate Series Control is a perfect fit for larger spas. It can control two single or dual speed pumps, an air blower, an electric heater, ozonator, circulation pump, fiber optics to meet the demands of today’s market. The 9600 and it’s HT-2 spaside control keypad allow the users to control all of the functions and programming from spa side.Energy The HT-2 / 9600 Series Control can be configured for maximumConservation energy efficiency. It can control electric, gas or solar heat. The filtration cycle can be configured to run at non-peek hours of the day. The economy mode can be set to come on during peek hours, which will keep the spa 20°F below the Set Point.Features • Automatic time-out on all outputs • LCD display • LCD temperature display • Spaside control High-Limit reset • Sensor failure detection • Programmable filtration cycle • High-Limit protection • Pressure switch failure detection • Current limiting option • Freeze protection • Temperature measurement within +1°FHT-2 Spaside • Temperature set pointControl • Temperature display in °C or °F • Pump 1 control • Pump 2 control • Air Blower control (3-speeds) • Light control (up to 3 intensities) • Fiber Optic control • High-Limit temperature reset • Programmable filtration cycle • Smart Winter Mode http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
  • 5. HT-2 / 9600 Series Installation Spaside ControlConnection to The HT-2 Spaside control mustControl Box be securely connected to the systems circuit board or to the external receptacle. Connect the spaside control as shown.Pump 1 Key The Pump 1 Key is used to turn the pump on and to select high and low speeds (dual speed pump). Press the Pump 1 Key to turn the pump on in low speed. A second press will change the pump to high speed. A third press will turn the pump off. The Pump 1 Icon will appear while the pump is running. The pump will shut off automatically after 20 minutes unless done so manually.Pump 2 Key The Pump 2 Key is used to turn the pump on and to select high and low speeds (dual speed pump). Press the Pump 2 Key to turn the pump on in low speed. A second press will change the pump to high speed. A third press will turn the pump off. The Pump Icon will appear while the pump is running. The pump will shut off automatically after 20 minutes unless done so manually. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
  • 6. HT-2 / 9600 Series Instructions Spaside ControlBlower Key The Blower Key is used to turn the blower on and off or to select between high, medium, low speed and off (three speed). Press the Blower Key to turn the blower onto high speed. A second press will turn the blower off or change the speed to medium (three speed). A third press will turn the blower onto low speed. A fourth press will turn the blower off. The Blower Icon will appear when the blower is on. The blower will shut off automatically after 20 minutes unless done so manually.Light Key The Light Key is used to turn the(Without Fiber Light on and off or to selectOptics) between high, medium and low intensities and off. Press the Light Key to turn the light on. A second press will turn the light off or change it to medium intensity. A third press will turn the light to low intensity and a fourth press will turn the light off. The Light Icon will appear when the light is on. The light will shut off automatically after 2 hours unless done so manually. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
  • 7. HT-2 / 9600 Series Instructions Spaside ControlLight Key The first press of the Light Key(With Fiber Optics) will show “L1” on the display. Use the Up Arrow Key to set the light intensity to high, medium, low then to Off. Press the Light Key a second time, “F1” will be displayed. Use the Up Arrow Key to select fiber optic light and color wheel on, fiber optic light only and both off. The Light Icon will appear when the light is on. The light will shut off automatically after 2 hours unless done so manually.Program Key The Program Key is used to program the filtration cycle, Economy Mode, Temperature Unit and Spaside Lock. Press the Program Key, the Program Icon will appear in the upper window and CL will appear in the lower window. This is the parameter used to set the time. Pressing the Blower Key will move you through each parameter. To enter a parameter and modify it, press the Light Key. Use the Up & Down Arrow Keys to adjust the value. Press the Program Key to exit this mode. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
  • 8. HT-2 / 9600 Series Instructions Spaside ControlProgram Key Time of Day: “CL” will appear in the LCD window. Set any time from 00:00 to 23:59. Filtration Cycle Start Time: “FIon” will appear in the LCD window. Set time from 00:00 to 11:59. Filtration Duration: “ FIdu” will appear in the LCD window. Set duration from Off (no filtration) to 12:00 (continuous filtration). Economy Start Time: “ECon” will appear in the LCD window. Set any time from 00:00 to 23:59. Economy Duration: “ECdu” will appear in the LCD window. Set any hour from Off to 24:00 (always on). Temperature in F° or C°: “Tu” will appear in the LCD window. Set either F or C. Spa-Side Lock: “Loc” will appear in the LCD window. Set to either On or Off. While the Spa-Side is locked you will not be able to change the programming, adjust the Set Point temperature or change the Economy Mode. This mode is a helpful when small children are using the spa. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
  • 9. HT-2 / 9600 Series Instructions Spaside ControlEconomy Key This key is used to switch between Economy and Normal modes. The Economy Mode will maintain the water temperature at a point 20°F below the set temperature. This mode is recommended for occasional use when a minimal heating time is required. The Normal Mode will automatically maintain the water temperature at the desired set point. This mode is recommended for users that desire the spa to be available 24 hours a day.Up & Down Arrow The Up & Down Arrow Keys areKeys used to set the spa water temperature, which can be adjusted from 59°F to 104°F in 1°F increments. Keeping pressure on the key will increase (or decrease) the current temperature setting. The Set Point Icon will appear telling the user that the temperature displayed is the desired and not the actual temperature. If when the temperature is set to 104°F the user keeps the Up Arrow Key depressed for 5 seconds, the unit will go into “over temperature” mode. This allows the Set Point to be raised up to 107°F. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
  • 10. HT-2 / 9600 Series Instructions Spaside ControlHeater Auto Start When the water temperature is 1°F lower than the Set Point, the heater and pump will be turned on until the water temperature reaches the Set Point plus 1°F. The Heater Icon will appear while the heater is on.Temperature The 3-digit LCD display showsDisplay the water temperature reading. The reading will be refreshed every second. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
  • 11. HT-2 / 9600 Series Instructions Spaside Control (Alarms)Freeze Protection If the spa water temperature falls to 38°F at the high limit sensor, the system will activate the pump (low speed for dual speed pump) and heater for 2 minutes.High Temperature If the water temperature exceeds 112°F at the Temperature sensor, the heater and all functions will be deactivated and “3- flashing dots” will appear below the temperature display and an error LED will illuminate on the systems printed circuit board. If the water temperature exceeds 119°F at the Hi-Limit sensor the heater will be turned off until the water has cooled to 110°F. “3-flashing dots” will appear below the temperature display and an error LED will illuminate on the systems printed circuit board.Pressure Switch To prevent damage to your heater due to “dry fire”, there is a flow or pressure switch mounted to the heater. The system constantly checks the switch. If the pump used to circulate the water through the heater is not operating and the pressure switch is closed, “3-flashing dots” will appear below the temperature display. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
  • 12. HT-2 / 9600 Series Instructions Spaside Control (Alarms)Pressure Switch If the pump is operating and the flow or pressure switch is open, “3-flashing dots” will appear below the temperature display and the heater will not engage. Note: A dirty filter limiting the water flow or low spa water level can cause this message to appear. When the pump is turned on, there is a 7-second delay before the heater system will start to auto check the pressure switch.Temperature If the system detects a problemSensor with the water temperature sensor, 32°F will appear and remain on the Spaside display. The system will engage the heater as a form of freeze protection. If, in 1-hour, the system has not sensed a rise in the temperature, “3-flashing dots” will also appear below the temperature display.Freeze Protection If the spa water temperature drops below 49°F, the pump and heater will be turned for a period of 2 minutes or until the spa water reaches 50°F. The Filter Icon will appear during this mode. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
  • 13. HT-2 / 9600 Series Instructions Spaside Control (Alarms)Smart Winter Hydro-Quip solid-state systems are equipped with a sensor thatMode measures the temperature in the plumbing of the spa. If the system detects conditions below 59°F, the system will automatically activate the Smart Winter Mode for a period of 24 hours. In this mode, if a pump has not been powered in the last 2 hours, the system will turn it on for one minute to prevent freezing. The Filter Mode light Icon will flash while the pump is running in this mode.Power Failure Upon first powering the system or if a power outage occurs, the display will flash until a key is pressed. This feature also lets the user know there has been a power failure. The onboard clock may need to be reprogrammed. Normally the onboard clock will keep the correct time for at least 48 hours after a power outage. A power outage will not affect the programming. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
  • 14. HT-2 / 9600 Series Programming Low Level ProgrammingIt is possible to change the parameters of the Equipment System by positioning specific jumperslocated on the system board.To enter the Low Level Programming press and hold the Program Key for 20 seconds until thefirst programming parameter appears, which is P1 for Pump 1. Use Up and Down Arrow Keys toincrease or decrease the programming value. Press the Light Key to continue through eachprogramming parameter using the Up and Down Arrow Keys to set the value. You mustcontinue through all parameters to exit this mode.P1 (Pump 1) Value 1 – Single Speed Value 2 – Dual SpeedP2 (Pump 1) Value 0 – No Second Pump Value 1 – Single Speed Value 2 – Dual SpeedbL (Blower) Value 0 – No Air Blower Value 1 – Single Speed / 20 minute timeout Value 2 – Two Speed / 20 min. timeout Value 3 – Three Speed / 20 min. timeout Value 4 – Single Speed / 2-hour timeout Value 5 – Single Speed / 6-hour timeout Value 6 – Single Speed / 12-hour timeoutL1 (Light) Value 0 – No Light Value 1 – 12VAC Single Intensity Value 2 – 12VAC Three Intensities Value 3 – 120VAC LightO3 (Ozone) Value 0 – No Ozone Value 1 – On during filtration only Value 2 – Always OnAU (Fiber Optic) Value 0 – No Fiber Optics Value 1 – Fiber Optics InstalledTi (Time) Value 12 – Standard Clock Value 24 – 24-hour (military clock)Cu (Current) Value 0 – No Heat with High Speed Pump or Blower (120VAC) Value 1 – No Current Restriction (240VAC)Cp (Circ. Pump) Value 0 – No Circulation Pump Value 1 – Regulated with Spa Temperature Value 2 – Always Onr (Sensor Calibration) Value can be adjusted from 46.0 to 55.9 (this number is marked on the temperature sensor and is programmed at the factory). http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
  • 15. HT-2 / 9600 Series Control Wiring Diagram http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094