Portable, Continuous and Laboratory Instrumentation for monitoring air, water and process streams for a wide range of industrial hygiene, environmental and analytical applications.
4. Photos of 102 and 115Photos of 102 and 115
102 PID with spare head102 PID with spare head 115 FID with hydride tank115 FID with hydride tank
httphttp://www.hnu.com://www.hnu.com
5. GC312 Portable GCGC312 Portable GC
GC 312GC 312 FeaturesFeatures
Embedded PCEmbedded PC
Detectors: PID, FID, FUV,Detectors: PID, FID, FUV,
FPD, TCD 1 or 2 detectorsFPD, TCD 1 or 2 detectors
Windows 7.0Windows 7.0
PeakWorks ChromatographyPeakWorks Chromatography
softwaresoftware
Refillable carrier cylinderRefillable carrier cylinder
lasts for 30 hourslasts for 30 hours
Battery lasts for 6-8 hoursBattery lasts for 6-8 hours
ppb to % sensitivity-ppb to % sensitivity-
depends on detectordepends on detector
http://www.hnu.comhttp://www.hnu.com
6. Continuous AnalyzersContinuous Analyzers
Model 201 C, 202, 204, 210Model 201 C, 202, 204, 210
Smart microprocessor meterSmart microprocessor meter
– Bright LED meter 2 line x 16 characterBright LED meter 2 line x 16 character
displaydisplay
– 1-4 channel analog inputs1-4 channel analog inputs
– 1 channel readout at a time1 channel readout at a time
– Data storage 1Data storage 1
– Flexible SWFlexible SW
http://www.hnu.comhttp://www.hnu.com
8. Photos of 201C and 112Photos of 201C and 112
Model 201CModel 201C Model 204 TCDModel 204 TCD
http://www.hnu.comhttp://www.hnu.com
9. Process GC Analyzer- 301CProcess GC Analyzer- 301C
Model 301C 19” Rack MountModel 301C 19” Rack Mount
http://www.hnu.comhttp://www.hnu.com
10. Laboratory AnalyzersLaboratory Analyzers
Model PI 52-02 C- PhotoionizationModel PI 52-02 C- Photoionization
DetectorDetector
Model FI-53-01 flame ionization detectorModel FI-53-01 flame ionization detector
Model TC-54-01 thermal conductivityModel TC-54-01 thermal conductivity
detectordetector
Model FUV-55-01 Far UV DetectorModel FUV-55-01 Far UV Detector
Model FP-56-01- flame photometricModel FP-56-01- flame photometric
detectordetector
http://www.hnu.comhttp://www.hnu.com
11. GC Detectors for the LabGC Detectors for the Lab
Electrometer forElectrometer for
DetectorsDetectors Stand Alone DetectorsStand Alone Detectors
PID, FID, FUV, FPD,PID, FID, FUV, FPD,
TCDTCD for any GCfor any GC
http://www.hnu.comhttp://www.hnu.com
12. GC Detector ResponseGC Detector Response
PID-PID- one of the most sensitive detectorsone of the most sensitive detectors
available for HC- can be up to 100x moreavailable for HC- can be up to 100x more
sensitive than the FIlD- low ppb detectionsensitive than the FIlD- low ppb detection
FID-FID-for CH4 and any hydrocarbonfor CH4 and any hydrocarbon
FUV-FUV- inorganic + organic compounds at low orinorganic + organic compounds at low or
sub ppm levelssub ppm levels
FPD-FPD- Selective for S or P compoundsSelective for S or P compounds
TCD-TCD- universal detector ppm to %universal detector ppm to %
http://www.hnu.comhttp://www.hnu.com
13. Arsenic Analyzer for Food & WaterArsenic Analyzer for Food & Water
Model 33 Arsenic AnalyzerModel 33 Arsenic Analyzer
Hydride Generation/GasHydride Generation/Gas
Chromatography/PhotoionizationChromatography/Photoionization
HG/GC/PIDHG/GC/PID
http://www.hnu.comhttp://www.hnu.com
A New Technology for Detection of Inorganic Arsenic in food &A New Technology for Detection of Inorganic Arsenic in food &
WaterWater