EXPERIMENTAL ANALYSIS OF TURBULENT
FLOW HEAT TRANSFER IN A RECTANGULAR
DUCT WITH AND WITHOUT CONTINUOUS
AND DISCRETE V-SHAPED INTERNAL RIBS
Pankaj N. Shrirao1
, Rahul M. Sherekar2
, Sachin V. Bhalerao3
1 2 3
Department of Mechanical Engineering
1 2 3
Jawaharlal Darda Institute of Engg. & Technology
M.I.D.C. Area, Lohara, Yavatmal-445001 Maharashtra, India
1
pn_shrirao@yahoo.co.in
ABSTARCT:
In this present work, Experiments were performed to collect heat transfer and friction data for forced
convection flow of air in rectangular duct with and without internal ribs. The analysis was conducted
within the range of Reynolds number from 3000 to 18000. The horizontal rectangular duct was subjected
to constant and uniform heat flux. Experimental results for this configuration are reported for three
different channels viz., smooth rectangular duct, rectangular duct with continuous V- shaped ribs and
rectangular duct with discrete V- shaped ribs. The effects of internal ribs on the heat transfer coefficient
and friction factor are compared with the result of smooth duct under similar flow conditions.
Experimental results show that the local Nusselt number distribution is strongly depended on the
position, orientation, and geometry of the ribs. The friction factor ratio goes up with an increase in the
Reynolds number, but its value depends on the arrangement of ribs. The results also show that the
discrete V- shaped ribs produce overall less heat transfer enhancement than the continuous V- shaped
ribs. However, the increased heat transfer enhancement in the continuous V- shaped ribs came at the cost
of an increased pressure penalty.
Keywords: Heat transfer augmentation; Forced convection heat transfer; Internal ribs; Rectangular duct.
.
1. INTRODUCTION
Heat exchangers have been widely employed in several industrial and engineering applications. The Techniques
for enhancing heat transfer are relevant to several engineering applications. In recent years, the high cost of
energy and material has resulted in an increased effort aimed at producing more efficient heat exchange
equipment. The heat transfer rate can be improved by introducing a disturbance in the fluid flow (breaking the
viscous and thermal boundary layers), but in the process, pumping power may increase significantly and
ultimately the pumping cost becomes high. Therefore, to achieve a desired heat transfer rate in an existing heat
exchanger at an economic pumping power, several techniques have been proposed in recent years. The great
attempt on utilizing different methods is to increase the heat transfer rate through the compulsory force
convection. The meanwhile, it is found that this way can reduce the sizes of the heat exchanger device and save
up the energy. M. Sozen and T.M. Kuzay [1] numerically studied the enhanced heat transfer in round tubes
filled with rolled copper mesh at Reynolds number range of 5,000-19,000. With water as the energy transport
fluid and the tube being subjected to uniform heat flux, they reported up to ten fold increase in heat transfer
coefficient with brazed porous inserts relative to plain tube at the expense of highly increased pressure drop. Q.
Liao and M.D. Xin [2] carried out experiments to study the heat transfer and friction characteristics for water,
ethylene glycol and ISOVG46 turbine oil flowing inside four tubes with three dimensional internal extended
surfaces and copper continuous or segmented twisted tape inserts within Prandtl number range from 5.5 to 590
and Reynolds numbers from 80 to 50,000. They found that for laminar flow of VG46 turbine oil, the average
E-ISSN: 2321–9637
Volume 2, Issue 1, January 2014
International Journal of Research in Advent Technology
Available Online at: http://www.ijrat.org
60
Stanton number could be enhanced up to 5.8 times with friction factor increase of 6.5 fold compared to plain
tube. D. Angirasa [3] performed experiments that proved augmentation of heat transfer by using metallic fibrous
materials with two different porosities namely 97% and 93%. The experiments were carried out for different
Reynolds numbers (17,000-29,000) and power inputs (3.7 and 9.2 W). The improvement in the average Nusselt
number was about 3-6 times in comparison with the case when no porous material was used. Fu et al. [4]
experimentally demonstrated that a channel filled with high conductivity porous material subjected to oscillating
flow is a new and effective method of cooling electronic devices. The experimental investigations of Hsieh and
Liu [5] reported that Nusselt numbers were between four and two times the bare values at low Re and high Re
respectively. Bogdan and Abdulmajeed et al. [6] numerically investigated the effect of metallic porous
materials, inserted in a pipe, on the rate of heat transfer. The pipe was subjected to a constant and uniform heat
flux. The effects of porosity, porous material diameter and thermal conductivity as well as Reynolds number on
the heat transfer rate and pressure drop were investigated. The results were compared with the clear flow case
where no porous material was used. The results obtained lead to the conclusion that higher heat transfer rates
can be achieved using porous inserts at the expense of a reasonable pressure drop. Smith et. al. [7] investigated
the heat transfer enhancement and pressure loss by insertion of single twisted tape, full length dual and regularly
spaced dual twisted tapes as swirl generators in round tube under axially uniform wall heat flux conditions.
Chinaruk Thianpong et.al. [8] Experimentally investigated the friction and compound heat transfer behavior in
dimpled tube fitted with twisted tape swirl generator for a fully developed flow for Reynolds number in the
range of 12000 to 44000. Whitham [9] studied heat transfer enhancement by means of a twisted tape insert way
back at the end of the nineteenth century. Date and Singham [10] numerically investigated heat transfer
enhancement in laminar, viscous liquid flows in a tube with a uniform heat flux boundary condition. They
idealized the flow conditions by assuming zero tape thickness, but the twist and fin effects of the twisted tape
were included in their analysis. Saha et al. [11] have shown that, for a constant heat flux boundary condition,
regularly spaced twisted tape elements do not perform better than full-length twisted tape because the swirl
breaks down in-between the spacing of a regularly twisted tape. Rao and Sastri [12], while working with a
rotating tube with a twisted tape insert, observed that the enhancement of heat transfer offsets the rise in the
friction factor owing to rotation. Sivashanmugam and Sundaram [13] and Agarwal and Rao [14] studied the
thermohydraulic characteristics of tape-generated swirl flow. Peterson et al. [15] experimented with high-
pressure (8–16 MPa) water as the test liquid in turbulent flow with low heat fluxes and low wall–fluid
temperature differences typical of a liquid–liquid heat exchanger.
The present experimental study investigates the increase in the heat transfer rate in a rectangular duct heated
with a constant uniform heat flux with air flowing inside it using continuous and discrete V-shaped internal ribs
of same geometrical configuration. The present work has been carried out with turbulent flow (Re number range
of 3,000-18,000) as most of the flow problems in industrial heat exchangers involve turbulent flow region.
2. EXPERIMENTAL WORK
2.1. Experimental Setup
The apparatus consists of a blower unit fitted with a pipe, which is connected to the test section located in
horizontal orientation. Nichrome bend heater encloses the test section to a length of 50 cm. Four thermocouples
T2, T3 and T4 at a distance of 11 cm, 22 cm, 33 cm and 44 cm from the origin of the heating zone are
embedded on the walls of the tube and two thermocouples are placed in the air stream, one at the entrance (T1)
and the other at the exit (T5) of the test section to measure the temperature of flowing air as shown in Fig. 1.
The pipe system consists of a valve, which controls the airflow rate through it and an orifice meter to find the
volume flow rate of air through the system. The diameter of the orifice is 1.4 cm and coefficient of discharge is
0.64. The two pressure tapings of the orifice meter are connected to a water U-tube manometer to indicate the
pressure difference between them. Input to heater is given through dimmer stat. Display unit consists of
E-ISSN: 2321–9637
Volume 2, Issue 1, January 2014
International Journal of Research in Advent Technology
Available Online at: http://www.ijrat.org
61
voltmeter, ammeter and temperature indicator. The circuit was designed for a load voltage of 0-220 V; with a
maximum current of 10 A. Difference in the levels of manometer fluid represents the variations in the flow rate
of air. The velocity of airflow in the tube is measured with the help of orifice plate and the water manometer
fitted on board.
2.2 Procedure
Air was made to flow though the test duct by means of blower motor. A heat input of 60 W was given to the
nichrome heating wire wound on the test duct by adjusting the dimmer stat. The test duct was insulated in order
to avoid the loss of heat energy to the surrounding. Thermocouples 2 to 4 were fixed on the test surface and
thermocouples 1 and 5 were fixed inside the pipe. The readings of the thermocouples were observed every 5
minutes until the steady state condition was achieved. Under steady state condition, the readings of all the five
thermocouples were recorded. The experiments were repeated for different channels viz., rectangular duct with
continuous V- shaped ribs and rectangular duct with discrete V- shaped ribs. The fluid properties were
calculated as the average between the inlet and the outlet bulk temperature. Experiments were carried out at
constant heat input and constant mass flow rate, for all the three test ducts.
Fig. 1 Experimental Set-up
Fig.2 Continuous and Discrete internal V-shaped ribs Configurations on upper and lower surface of rectangular duct
E-ISSN: 2321–9637
Volume 2, Issue 1, January 2014
International Journal of Research in Advent Technology
Available Online at: http://www.ijrat.org
62
3. DATA REDUCTION
The data reduction of the measured results is summarized in the following procedures:
The heat transfer coefficient for the “i” wall segment was calculated using the net heat input to the wall; the wall
temperature and the bulk mean temperature as
hi= qi / As,i (Tw,i - Tb,i) (1)
The actual heat going into the duct is given by the amount of power supplied which is the product of voltage
applied and the current flowing in the circuit minus the amount of heat loss from each plate. The flexible heaters
were assumed to supply uniform heat to all the test ducts. The heat loss from the test section to the surrounding
was calculated experimentally by conducting a no-flow condition. The heat loss to the surrounding was found to
vary between 5-15% for various Reynolds number. The major heat loss was found to occur through the thick
wired copper thermocouples installed in each wall segment.
The Nusselt number was normalized using the Nusselt number correlation for a fully developed flow in
a smooth duct. The relative uncertainty on Nusselt number was found to be 5%.
Nu / Nuo = (hDh/ K) [0.023 Re 0.8
Pr 0.4
] (2)
All the temperatures were measured using the thermocouples. The bulk mean air temperature at the inlet and the
exit was measured using the thermocouples and the bulk mean temperature at the end of each test duct was
calculated using the formula given by
Tb,out = Tb,in + q/ (m Cp ) (3)
The pressure drop measured with a micro-manometer across the test section, was used to calculate the friction
factor. The relation between pressure drop and friction factor is given by
(4)
The fiction factor is normalized by Gnielinski equation
fo =[0.79 ln (ReDh)- 1.64]-2
(5)
The correlation for thermal performance is given by
TP = (Nu / Nuo)/ (f/fo) 1/3
(6)
4. RESULT AND DISCUSSION
Heat Transfer Distribution for smooth rectangular duct, rectangular duct with continuous V- shaped ribs
and rectangular duct with discrete V- shaped ribs:
The Nusselt number was found to increase with increasing Reynolds number. The reason attributed to this
behavior is as Reynolds number increases the turbulent mixing is enhanced in the channel, which leads to
E-ISSN: 2321–9637
Volume 2, Issue 1, January 2014
International Journal of Research in Advent Technology
Available Online at: http://www.ijrat.org
63
effective removal of heat. However, the Nusselt number ratio, which is obtained by normalizing the average
Nusselt number with the fully developed turbulent flow in smooth test tube correlated by Dittus Boelter, was
found to decrease as shown in Fig 3.
In the case of smooth test duct the variation of Nusselt number ratio with increasing Reynolds number is very
small as there is no flow separation and reattachments in this case and so Reynolds number does not have any
effect on the heat transfer augmentation. Therefore, the Nusselt number ratio for all four Reynolds number
follow a similar trend. The Nusselt number ratio was found to be highest for the lowest Reynolds number and
lowest for the highest Reynolds number. It was found to vary between 2.15 and 1.1 along the axial direction.
0
0.5
1
1.5
2
2.5
1 2 3 4
X/Dh
Nu/Nuo
5000
8000
12500
15600
Fig.3 Effect of Reynolds Number on Heat Transfer Distribution for Smooth Rectangular duct
The heat transfer augmentation for rectangular duct with continuous V- shaped ribs was found to increase by
factor of 1.7 to 2.1 in comparison to the smooth rectangular duct and by a factor of 1.06 to 1.20 in comparison to
the rectangular duct with discrete V- shaped ribs. The increase in heat transfer coefficient is attributed to the
induction of cross-stream secondary flow, which results in better turbulent mixing.
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
1 2 3 4
X/Dh
Nu/Nuo
5000
8000
12500
15600
Fig.4 Effect of Reynolds Number on Heat Transfer Distribution for Rectangular duct with continuous V- shaped ribs
E-ISSN: 2321–9637
Volume 2, Issue 1, January 2014
International Journal of Research in Advent Technology
Available Online at: http://www.ijrat.org
64
0
0.5
1
1.5
2
2.5
3
3.5
4
1 2 3 4
X/Dh
Nu/Nuo
5000
8000
12500
15600
Fig.5 Effect of Reynolds Number on Heat Transfer Distribution for Rectangular duct with discrete V- shaped ribs
Friction Factor Characteristics for smooth rectangular duct, rectangular duct with continuous V- shaped
ribs and rectangular duct with discrete V- shaped ribs:
The friction factor ratio was found to increase with increase in Reynolds number due to the resistance offered to
the flow of fluid. The heat transverse augmentation was found to vary between 1.5-2 for the rectangular duct
with discrete V- shaped ribs and 2-2.5 for the rectangular duct with continuous V- shaped ribs. This
enhancement in both the cases was accompanied by pressure drop penalty of 1.5 to 3 on the rectangular duct
with discrete V- shaped ribs and 3 to 4 on the rectangular duct with continuous V- shaped ribs. The rectangular
duct with continuous V- shaped ribs produced 20 % to 40% higher pressure drop when compared to the
rectangular duct with discrete V- shaped ribs for the complete range of Reynolds number investigated.
Fig. 6 Average Friction Factor Ratio versus Reynolds Number for Various Configurations
E-ISSN: 2321–9637
Volume 2, Issue 1, January 2014
International Journal of Research in Advent Technology
Available Online at: http://www.ijrat.org
65
Thermal Performance:
Thermal performance for the plate with internal ribs is drawn as below in fig. 7, shows that thermal performance
is increasing with increase in Reynolds number. But the thermal performance for rectangular duct with discrete
V- shaped ribs is poor as compared to the rectangular duct with continuous V- shaped ribs. This is due more
turbulence and strong vortex formation in rectangular duct with continuous V- shaped ribs. Also it reflects that
thermal performance of rectangular duct with continuous V- shaped ribs is more than one which means applying
continuous V- shaped ribs is beneficial to increase heat transfer enhancement.
Fig. 7 Variation of Thermal Performance with Reynolds Number for Various Configurations
Acknowledgments
We are thankful to the Hon. Principal Dr. A.W. Kolhatkar and Head of Department Dr. A. B. Borade,
Jawaharalal Darda Institute of Engineering and Technology, Yavatmal, Maharashtra, India for providing
Mechanical Engineering Research Laboratory for Experimentation study and their moral support.
References
[1] M. Sozen and T M. Kuzay (1996), “Enhanced heat transfer in round tubes with porous inserts”, International Journal Heat and
Fluid Flow, Vol. 17, pp.124-129
[2] Q. Liao and M.D. Xin (2000), “Augmentation of convective heat transfer inside tubes with three-dimensional internal extended
surfaces and twisted-tape inserts”, Chemical Engineering Journal, Vol. 78, pp. 95-105
[3] D. Angirasa (2001), “Experimental investigation of forced convection heat transfer augmentation with metallic porous
materials”, International Journal of Heat Mass Transfer, pp. 919-922
[4] H.L. Fu, K.C. Leong, X.Y. Huang and C.Y. Liu (2001), “An experimental study of heat transfer of a porous channel subjected to
oscillating flow”, ASME Journal of Heat Transfer, Vol. 123, pp.162-170.
[5] S.S Hsieh, M.H. Liu, H.H. Tsai (2003), “Turbulent heat transfer and flow characteristic in a horizontal circular tube with strip-
type inserts part-II (heat transfer)”, International Journal of Heat and Mass Transfer, Vol. 46, pp.837-849.
[6] B.I. Pavel and A.A. Mohamad (2004), “ An experimental and numerical study on heat transfer enhancement for gas heat
exchangers fitted with porous media”, International Journal of Heat and Mass Transfer, Vol. 47, pp.4939-4952.
[7] Smith Eiamsa-ard, Chinaruk Thianpong, Petpices Eiamsa-ard and Pongjet Promvonge (2009), “Convective heat transfer in a
circular tube with short-length twisted tape insert”, International communications in heat and mass transfer (2009).
E-ISSN: 2321–9637
Volume 2, Issue 1, January 2014
International Journal of Research in Advent Technology
Available Online at: http://www.ijrat.org
66
[8] Chinaruk Thianpong, Petpices Eiamsa-ard, Khwanchit Wongcharee and Smith Eiamsaard (2009), Compound heat transfer
enhancement of a dimpled tube with a twisted tape swirl generator, International Communications in Heat and Mass Heat and
Mass Transfer, Vol. 36, pp. 698-704.
[9] Whitham, J. M (1896), The effects of retarders in fire tubes of steam boilers, Street Railway, Vol. 12(6), pp. 374.
[10] Date, A. W. and Singham, J. R. (1972), “Numerical prediction of friction and heat transfer characteristics of fully developed
laminar flow in tubes containing twisted tapes”, Trans. ASME, Journal of Heat Transfer, Vol. 17, pp. 72
[11] S.K.Saha, U.N.Gaitonde and A.W. Date (1989), “Heat transfer and pressure drop characteristics of laminar flow in a circular
tube fitted with regularly spaced twisted-tape elements”, Journal of Exp. Thermal Fluid Sci., Vol. 2, pp.310-322.
[12] Rao, M. M. and Sastri, V. M. K. (1995), “Experimental investigation for fluid flow and heat transfer in a rotating tube twisted
tape inserts”, International Journal of Heat and Mass Transfer, Vol.16, pp.19–28.
[13] Sivashanmugam, P. and Suresh, S. (2007), “Experimental studies on heat transfer and friction factor characteristics of turbulent
flow through a circular tube fitted with regularly spaced helical screw tape inserts”, Experimental Thermal and Fluid Science,
Vol. 31, pp. 301-308.
[14] Agarwal, S. K. and Raja Rao, M. (1996), “Heat transfer augmentation for flow of viscous liquid in circular tubes using twisted
tape inserts”, International Journal of Heat Mass Transfer, Vol. 99, pp.3547–3557.
[15] Peterson, S. C., France, D. M. and Carlson, R. D. (1989), “Experiments in high-pressure turbulent swirl flow”, Trans. ASME,
Journal of Heat Transfer, Vol. 108, pp.215–218.

More Related Content

What's hot

Heat transfer enhancement and friction factor analysis in tube using conical ...
Heat transfer enhancement and friction factor analysis in tube using conical ...Heat transfer enhancement and friction factor analysis in tube using conical ...
Heat transfer enhancement and friction factor analysis in tube using conical ...
eSAT Journals
 
EXPERIMENTAL STUDY ON THE ANALYSIS OF HEAT ENHANCEMENT IN CORRUGATED TWISTED ...
EXPERIMENTAL STUDY ON THE ANALYSIS OF HEAT ENHANCEMENT IN CORRUGATED TWISTED ...EXPERIMENTAL STUDY ON THE ANALYSIS OF HEAT ENHANCEMENT IN CORRUGATED TWISTED ...
EXPERIMENTAL STUDY ON THE ANALYSIS OF HEAT ENHANCEMENT IN CORRUGATED TWISTED ...
P singh
 

What's hot (17)

Gd3411261132
Gd3411261132Gd3411261132
Gd3411261132
 
Ld35191119013
Ld35191119013Ld35191119013
Ld35191119013
 
At4301239243
At4301239243At4301239243
At4301239243
 
An Experimental Research on Heat Transfer Enhancement of a Circular Tube with...
An Experimental Research on Heat Transfer Enhancement of a Circular Tube with...An Experimental Research on Heat Transfer Enhancement of a Circular Tube with...
An Experimental Research on Heat Transfer Enhancement of a Circular Tube with...
 
Heat transfer enhancement and friction factor analysis in tube using conical ...
Heat transfer enhancement and friction factor analysis in tube using conical ...Heat transfer enhancement and friction factor analysis in tube using conical ...
Heat transfer enhancement and friction factor analysis in tube using conical ...
 
Irjet v4 i12326Effect of External Threaded Inside Tube on Heat Transfer Rate ...
Irjet v4 i12326Effect of External Threaded Inside Tube on Heat Transfer Rate ...Irjet v4 i12326Effect of External Threaded Inside Tube on Heat Transfer Rate ...
Irjet v4 i12326Effect of External Threaded Inside Tube on Heat Transfer Rate ...
 
EXPERIMENTAL STUDY ON THE ANALYSIS OF HEAT ENHANCEMENT IN CORRUGATED TWISTED ...
EXPERIMENTAL STUDY ON THE ANALYSIS OF HEAT ENHANCEMENT IN CORRUGATED TWISTED ...EXPERIMENTAL STUDY ON THE ANALYSIS OF HEAT ENHANCEMENT IN CORRUGATED TWISTED ...
EXPERIMENTAL STUDY ON THE ANALYSIS OF HEAT ENHANCEMENT IN CORRUGATED TWISTED ...
 
Bd34340346
Bd34340346Bd34340346
Bd34340346
 
Evaluation of Convective Heat Transfer Coefficient of Air Flowing Through an ...
Evaluation of Convective Heat Transfer Coefficient of Air Flowing Through an ...Evaluation of Convective Heat Transfer Coefficient of Air Flowing Through an ...
Evaluation of Convective Heat Transfer Coefficient of Air Flowing Through an ...
 
Experimental Investigation on Heat Transfer Enhancement in Laminar Flow in Ci...
Experimental Investigation on Heat Transfer Enhancement in Laminar Flow in Ci...Experimental Investigation on Heat Transfer Enhancement in Laminar Flow in Ci...
Experimental Investigation on Heat Transfer Enhancement in Laminar Flow in Ci...
 
Natural convection heat transfer inside inclined open cylinder
Natural convection heat transfer inside inclined open cylinderNatural convection heat transfer inside inclined open cylinder
Natural convection heat transfer inside inclined open cylinder
 
Experimental Investigation of Vertical Downward Flow Boiling Heat Transfer i...
Experimental Investigation of Vertical Downward Flow Boiling  Heat Transfer i...Experimental Investigation of Vertical Downward Flow Boiling  Heat Transfer i...
Experimental Investigation of Vertical Downward Flow Boiling Heat Transfer i...
 
ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR ...
ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR ...ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR ...
ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR ...
 
IRJET- Experiment Investigation of Heat Transfer Rate of Fins with Blind Hole...
IRJET- Experiment Investigation of Heat Transfer Rate of Fins with Blind Hole...IRJET- Experiment Investigation of Heat Transfer Rate of Fins with Blind Hole...
IRJET- Experiment Investigation of Heat Transfer Rate of Fins with Blind Hole...
 
D044081316
D044081316D044081316
D044081316
 
STUDY OF HEAT TRANSFER ON BROKEN ARC ROUGHNESS ELEMENTS ON THE ABSORBER PLATE...
STUDY OF HEAT TRANSFER ON BROKEN ARC ROUGHNESS ELEMENTS ON THE ABSORBER PLATE...STUDY OF HEAT TRANSFER ON BROKEN ARC ROUGHNESS ELEMENTS ON THE ABSORBER PLATE...
STUDY OF HEAT TRANSFER ON BROKEN ARC ROUGHNESS ELEMENTS ON THE ABSORBER PLATE...
 
Ee25796802
Ee25796802Ee25796802
Ee25796802
 

Viewers also liked (20)

Paper id 2320147
Paper id 2320147Paper id 2320147
Paper id 2320147
 
Paper id 212014104
Paper id 212014104Paper id 212014104
Paper id 212014104
 
Paper id 25201490
Paper id 25201490Paper id 25201490
Paper id 25201490
 
140814 texto-ten reasons not to write
140814 texto-ten reasons not to write140814 texto-ten reasons not to write
140814 texto-ten reasons not to write
 
Paper id 25201431
Paper id 25201431Paper id 25201431
Paper id 25201431
 
Paper id 23201429
Paper id 23201429Paper id 23201429
Paper id 23201429
 
Paper id 2520148
Paper id 2520148Paper id 2520148
Paper id 2520148
 
Paper id 24201493
Paper id 24201493Paper id 24201493
Paper id 24201493
 
Paper id 2520148 (2)
Paper id 2520148 (2)Paper id 2520148 (2)
Paper id 2520148 (2)
 
Paper id 25201492
Paper id 25201492Paper id 25201492
Paper id 25201492
 
Paper id 27201475
Paper id 27201475Paper id 27201475
Paper id 27201475
 
Paper id 25201423
Paper id 25201423Paper id 25201423
Paper id 25201423
 
Paper id 27201411
Paper id 27201411Paper id 27201411
Paper id 27201411
 
Paper id 27201419
Paper id 27201419Paper id 27201419
Paper id 27201419
 
Paper id 25201485
Paper id 25201485Paper id 25201485
Paper id 25201485
 
Executive Recruiter at the University of California, Berkeley!
Executive Recruiter at the University of California, Berkeley! Executive Recruiter at the University of California, Berkeley!
Executive Recruiter at the University of California, Berkeley!
 
Paper id 28201429
Paper id 28201429Paper id 28201429
Paper id 28201429
 
Paper id 27201446
Paper id 27201446Paper id 27201446
Paper id 27201446
 
Paper id 24201469
Paper id 24201469Paper id 24201469
Paper id 24201469
 
Paper id 24201448
Paper id 24201448Paper id 24201448
Paper id 24201448
 

Similar to Paper id 21201420

Effect of Wavy (Corrugated) Twisted Tape Inserts on Heat Transfer in a double...
Effect of Wavy (Corrugated) Twisted Tape Inserts on Heat Transfer in a double...Effect of Wavy (Corrugated) Twisted Tape Inserts on Heat Transfer in a double...
Effect of Wavy (Corrugated) Twisted Tape Inserts on Heat Transfer in a double...
ijiert bestjournal
 
Paper id 25201450
Paper id 25201450Paper id 25201450
Paper id 25201450
IJRAT
 

Similar to Paper id 21201420 (20)

Effect of Wavy Tube on Heat Transfer in a Concentric Tube Heat Exchanger: A R...
Effect of Wavy Tube on Heat Transfer in a Concentric Tube Heat Exchanger: A R...Effect of Wavy Tube on Heat Transfer in a Concentric Tube Heat Exchanger: A R...
Effect of Wavy Tube on Heat Transfer in a Concentric Tube Heat Exchanger: A R...
 
Effect of Wavy (Corrugated) Twisted Tape Inserts on Heat Transfer in a double...
Effect of Wavy (Corrugated) Twisted Tape Inserts on Heat Transfer in a double...Effect of Wavy (Corrugated) Twisted Tape Inserts on Heat Transfer in a double...
Effect of Wavy (Corrugated) Twisted Tape Inserts on Heat Transfer in a double...
 
Df4301619624
Df4301619624Df4301619624
Df4301619624
 
HEAT TRANSFER AUGMENTATION OF LAMINAR NANOFLUID FLOW IN HORIZONTAL TUBE INSER...
HEAT TRANSFER AUGMENTATION OF LAMINAR NANOFLUID FLOW IN HORIZONTAL TUBE INSER...HEAT TRANSFER AUGMENTATION OF LAMINAR NANOFLUID FLOW IN HORIZONTAL TUBE INSER...
HEAT TRANSFER AUGMENTATION OF LAMINAR NANOFLUID FLOW IN HORIZONTAL TUBE INSER...
 
Review Over The Effects Of Baffle Orientation And Shape Factor Over Pressure ...
Review Over The Effects Of Baffle Orientation And Shape Factor Over Pressure ...Review Over The Effects Of Baffle Orientation And Shape Factor Over Pressure ...
Review Over The Effects Of Baffle Orientation And Shape Factor Over Pressure ...
 
Thermo hydraulics performance of turbulent flow heat transfer through square ...
Thermo hydraulics performance of turbulent flow heat transfer through square ...Thermo hydraulics performance of turbulent flow heat transfer through square ...
Thermo hydraulics performance of turbulent flow heat transfer through square ...
 
Thermo hydraulics performance of turbulent flow heat transfer through square ...
Thermo hydraulics performance of turbulent flow heat transfer through square ...Thermo hydraulics performance of turbulent flow heat transfer through square ...
Thermo hydraulics performance of turbulent flow heat transfer through square ...
 
Experimental Investigation of Heat Transfer Enhancement by Using Clockwise an...
Experimental Investigation of Heat Transfer Enhancement by Using Clockwise an...Experimental Investigation of Heat Transfer Enhancement by Using Clockwise an...
Experimental Investigation of Heat Transfer Enhancement by Using Clockwise an...
 
Paper id 25201450
Paper id 25201450Paper id 25201450
Paper id 25201450
 
E351923
E351923E351923
E351923
 
E351923
E351923E351923
E351923
 
E351923
E351923E351923
E351923
 
IRJET-Enhancement of Heat Transfer through Pipe with the Help of Various Type...
IRJET-Enhancement of Heat Transfer through Pipe with the Help of Various Type...IRJET-Enhancement of Heat Transfer through Pipe with the Help of Various Type...
IRJET-Enhancement of Heat Transfer through Pipe with the Help of Various Type...
 
THERMO HYDRAULICS PERFORMANCE OF TURBULENT FLOW HEAT TRANSFER THROUGH SQUARE ...
THERMO HYDRAULICS PERFORMANCE OF TURBULENT FLOW HEAT TRANSFER THROUGH SQUARE ...THERMO HYDRAULICS PERFORMANCE OF TURBULENT FLOW HEAT TRANSFER THROUGH SQUARE ...
THERMO HYDRAULICS PERFORMANCE OF TURBULENT FLOW HEAT TRANSFER THROUGH SQUARE ...
 
Review of Heat Transfer Parameters using internal threaded pipe fitted with i...
Review of Heat Transfer Parameters using internal threaded pipe fitted with i...Review of Heat Transfer Parameters using internal threaded pipe fitted with i...
Review of Heat Transfer Parameters using internal threaded pipe fitted with i...
 
Analysis of Double Pipe Heat Exchanger With Helical Fins
Analysis of Double Pipe Heat Exchanger With Helical FinsAnalysis of Double Pipe Heat Exchanger With Helical Fins
Analysis of Double Pipe Heat Exchanger With Helical Fins
 
PERFORMANCE ENHANCEMENT OF HEAT EXCHANGERS USING VORTEX FLAPS
PERFORMANCE ENHANCEMENT OF HEAT EXCHANGERS USING VORTEX FLAPSPERFORMANCE ENHANCEMENT OF HEAT EXCHANGERS USING VORTEX FLAPS
PERFORMANCE ENHANCEMENT OF HEAT EXCHANGERS USING VORTEX FLAPS
 
CONVECTIVE HEAT TRANSFER ENHANCEMENTS IN TUBE USING LOUVERED STRIP INSERT
CONVECTIVE HEAT TRANSFER ENHANCEMENTS IN TUBE USING LOUVERED STRIP INSERTCONVECTIVE HEAT TRANSFER ENHANCEMENTS IN TUBE USING LOUVERED STRIP INSERT
CONVECTIVE HEAT TRANSFER ENHANCEMENTS IN TUBE USING LOUVERED STRIP INSERT
 
IRJET- Experimental Investigation of Enhancement of Convective Heat Trans...
IRJET-  	  Experimental Investigation of Enhancement of Convective Heat Trans...IRJET-  	  Experimental Investigation of Enhancement of Convective Heat Trans...
IRJET- Experimental Investigation of Enhancement of Convective Heat Trans...
 
S130403131140
S130403131140S130403131140
S130403131140
 

More from IJRAT

More from IJRAT (20)

96202108
9620210896202108
96202108
 
97202107
9720210797202107
97202107
 
93202101
9320210193202101
93202101
 
92202102
9220210292202102
92202102
 
91202104
9120210491202104
91202104
 
87202003
8720200387202003
87202003
 
87202001
8720200187202001
87202001
 
86202013
8620201386202013
86202013
 
86202008
8620200886202008
86202008
 
86202005
8620200586202005
86202005
 
86202004
8620200486202004
86202004
 
85202026
8520202685202026
85202026
 
711201940
711201940711201940
711201940
 
711201939
711201939711201939
711201939
 
711201935
711201935711201935
711201935
 
711201927
711201927711201927
711201927
 
711201905
711201905711201905
711201905
 
710201947
710201947710201947
710201947
 
712201907
712201907712201907
712201907
 
712201903
712201903712201903
712201903
 

Paper id 21201420

  • 1. E-ISSN: 2321–9637 Volume 2, Issue 1, January 2014 International Journal of Research in Advent Technology Available Online at: http://www.ijrat.org 59 EXPERIMENTAL ANALYSIS OF TURBULENT FLOW HEAT TRANSFER IN A RECTANGULAR DUCT WITH AND WITHOUT CONTINUOUS AND DISCRETE V-SHAPED INTERNAL RIBS Pankaj N. Shrirao1 , Rahul M. Sherekar2 , Sachin V. Bhalerao3 1 2 3 Department of Mechanical Engineering 1 2 3 Jawaharlal Darda Institute of Engg. & Technology M.I.D.C. Area, Lohara, Yavatmal-445001 Maharashtra, India 1 pn_shrirao@yahoo.co.in ABSTARCT: In this present work, Experiments were performed to collect heat transfer and friction data for forced convection flow of air in rectangular duct with and without internal ribs. The analysis was conducted within the range of Reynolds number from 3000 to 18000. The horizontal rectangular duct was subjected to constant and uniform heat flux. Experimental results for this configuration are reported for three different channels viz., smooth rectangular duct, rectangular duct with continuous V- shaped ribs and rectangular duct with discrete V- shaped ribs. The effects of internal ribs on the heat transfer coefficient and friction factor are compared with the result of smooth duct under similar flow conditions. Experimental results show that the local Nusselt number distribution is strongly depended on the position, orientation, and geometry of the ribs. The friction factor ratio goes up with an increase in the Reynolds number, but its value depends on the arrangement of ribs. The results also show that the discrete V- shaped ribs produce overall less heat transfer enhancement than the continuous V- shaped ribs. However, the increased heat transfer enhancement in the continuous V- shaped ribs came at the cost of an increased pressure penalty. Keywords: Heat transfer augmentation; Forced convection heat transfer; Internal ribs; Rectangular duct. . 1. INTRODUCTION Heat exchangers have been widely employed in several industrial and engineering applications. The Techniques for enhancing heat transfer are relevant to several engineering applications. In recent years, the high cost of energy and material has resulted in an increased effort aimed at producing more efficient heat exchange equipment. The heat transfer rate can be improved by introducing a disturbance in the fluid flow (breaking the viscous and thermal boundary layers), but in the process, pumping power may increase significantly and ultimately the pumping cost becomes high. Therefore, to achieve a desired heat transfer rate in an existing heat exchanger at an economic pumping power, several techniques have been proposed in recent years. The great attempt on utilizing different methods is to increase the heat transfer rate through the compulsory force convection. The meanwhile, it is found that this way can reduce the sizes of the heat exchanger device and save up the energy. M. Sozen and T.M. Kuzay [1] numerically studied the enhanced heat transfer in round tubes filled with rolled copper mesh at Reynolds number range of 5,000-19,000. With water as the energy transport fluid and the tube being subjected to uniform heat flux, they reported up to ten fold increase in heat transfer coefficient with brazed porous inserts relative to plain tube at the expense of highly increased pressure drop. Q. Liao and M.D. Xin [2] carried out experiments to study the heat transfer and friction characteristics for water, ethylene glycol and ISOVG46 turbine oil flowing inside four tubes with three dimensional internal extended surfaces and copper continuous or segmented twisted tape inserts within Prandtl number range from 5.5 to 590 and Reynolds numbers from 80 to 50,000. They found that for laminar flow of VG46 turbine oil, the average
  • 2. E-ISSN: 2321–9637 Volume 2, Issue 1, January 2014 International Journal of Research in Advent Technology Available Online at: http://www.ijrat.org 60 Stanton number could be enhanced up to 5.8 times with friction factor increase of 6.5 fold compared to plain tube. D. Angirasa [3] performed experiments that proved augmentation of heat transfer by using metallic fibrous materials with two different porosities namely 97% and 93%. The experiments were carried out for different Reynolds numbers (17,000-29,000) and power inputs (3.7 and 9.2 W). The improvement in the average Nusselt number was about 3-6 times in comparison with the case when no porous material was used. Fu et al. [4] experimentally demonstrated that a channel filled with high conductivity porous material subjected to oscillating flow is a new and effective method of cooling electronic devices. The experimental investigations of Hsieh and Liu [5] reported that Nusselt numbers were between four and two times the bare values at low Re and high Re respectively. Bogdan and Abdulmajeed et al. [6] numerically investigated the effect of metallic porous materials, inserted in a pipe, on the rate of heat transfer. The pipe was subjected to a constant and uniform heat flux. The effects of porosity, porous material diameter and thermal conductivity as well as Reynolds number on the heat transfer rate and pressure drop were investigated. The results were compared with the clear flow case where no porous material was used. The results obtained lead to the conclusion that higher heat transfer rates can be achieved using porous inserts at the expense of a reasonable pressure drop. Smith et. al. [7] investigated the heat transfer enhancement and pressure loss by insertion of single twisted tape, full length dual and regularly spaced dual twisted tapes as swirl generators in round tube under axially uniform wall heat flux conditions. Chinaruk Thianpong et.al. [8] Experimentally investigated the friction and compound heat transfer behavior in dimpled tube fitted with twisted tape swirl generator for a fully developed flow for Reynolds number in the range of 12000 to 44000. Whitham [9] studied heat transfer enhancement by means of a twisted tape insert way back at the end of the nineteenth century. Date and Singham [10] numerically investigated heat transfer enhancement in laminar, viscous liquid flows in a tube with a uniform heat flux boundary condition. They idealized the flow conditions by assuming zero tape thickness, but the twist and fin effects of the twisted tape were included in their analysis. Saha et al. [11] have shown that, for a constant heat flux boundary condition, regularly spaced twisted tape elements do not perform better than full-length twisted tape because the swirl breaks down in-between the spacing of a regularly twisted tape. Rao and Sastri [12], while working with a rotating tube with a twisted tape insert, observed that the enhancement of heat transfer offsets the rise in the friction factor owing to rotation. Sivashanmugam and Sundaram [13] and Agarwal and Rao [14] studied the thermohydraulic characteristics of tape-generated swirl flow. Peterson et al. [15] experimented with high- pressure (8–16 MPa) water as the test liquid in turbulent flow with low heat fluxes and low wall–fluid temperature differences typical of a liquid–liquid heat exchanger. The present experimental study investigates the increase in the heat transfer rate in a rectangular duct heated with a constant uniform heat flux with air flowing inside it using continuous and discrete V-shaped internal ribs of same geometrical configuration. The present work has been carried out with turbulent flow (Re number range of 3,000-18,000) as most of the flow problems in industrial heat exchangers involve turbulent flow region. 2. EXPERIMENTAL WORK 2.1. Experimental Setup The apparatus consists of a blower unit fitted with a pipe, which is connected to the test section located in horizontal orientation. Nichrome bend heater encloses the test section to a length of 50 cm. Four thermocouples T2, T3 and T4 at a distance of 11 cm, 22 cm, 33 cm and 44 cm from the origin of the heating zone are embedded on the walls of the tube and two thermocouples are placed in the air stream, one at the entrance (T1) and the other at the exit (T5) of the test section to measure the temperature of flowing air as shown in Fig. 1. The pipe system consists of a valve, which controls the airflow rate through it and an orifice meter to find the volume flow rate of air through the system. The diameter of the orifice is 1.4 cm and coefficient of discharge is 0.64. The two pressure tapings of the orifice meter are connected to a water U-tube manometer to indicate the pressure difference between them. Input to heater is given through dimmer stat. Display unit consists of
  • 3. E-ISSN: 2321–9637 Volume 2, Issue 1, January 2014 International Journal of Research in Advent Technology Available Online at: http://www.ijrat.org 61 voltmeter, ammeter and temperature indicator. The circuit was designed for a load voltage of 0-220 V; with a maximum current of 10 A. Difference in the levels of manometer fluid represents the variations in the flow rate of air. The velocity of airflow in the tube is measured with the help of orifice plate and the water manometer fitted on board. 2.2 Procedure Air was made to flow though the test duct by means of blower motor. A heat input of 60 W was given to the nichrome heating wire wound on the test duct by adjusting the dimmer stat. The test duct was insulated in order to avoid the loss of heat energy to the surrounding. Thermocouples 2 to 4 were fixed on the test surface and thermocouples 1 and 5 were fixed inside the pipe. The readings of the thermocouples were observed every 5 minutes until the steady state condition was achieved. Under steady state condition, the readings of all the five thermocouples were recorded. The experiments were repeated for different channels viz., rectangular duct with continuous V- shaped ribs and rectangular duct with discrete V- shaped ribs. The fluid properties were calculated as the average between the inlet and the outlet bulk temperature. Experiments were carried out at constant heat input and constant mass flow rate, for all the three test ducts. Fig. 1 Experimental Set-up Fig.2 Continuous and Discrete internal V-shaped ribs Configurations on upper and lower surface of rectangular duct
  • 4. E-ISSN: 2321–9637 Volume 2, Issue 1, January 2014 International Journal of Research in Advent Technology Available Online at: http://www.ijrat.org 62 3. DATA REDUCTION The data reduction of the measured results is summarized in the following procedures: The heat transfer coefficient for the “i” wall segment was calculated using the net heat input to the wall; the wall temperature and the bulk mean temperature as hi= qi / As,i (Tw,i - Tb,i) (1) The actual heat going into the duct is given by the amount of power supplied which is the product of voltage applied and the current flowing in the circuit minus the amount of heat loss from each plate. The flexible heaters were assumed to supply uniform heat to all the test ducts. The heat loss from the test section to the surrounding was calculated experimentally by conducting a no-flow condition. The heat loss to the surrounding was found to vary between 5-15% for various Reynolds number. The major heat loss was found to occur through the thick wired copper thermocouples installed in each wall segment. The Nusselt number was normalized using the Nusselt number correlation for a fully developed flow in a smooth duct. The relative uncertainty on Nusselt number was found to be 5%. Nu / Nuo = (hDh/ K) [0.023 Re 0.8 Pr 0.4 ] (2) All the temperatures were measured using the thermocouples. The bulk mean air temperature at the inlet and the exit was measured using the thermocouples and the bulk mean temperature at the end of each test duct was calculated using the formula given by Tb,out = Tb,in + q/ (m Cp ) (3) The pressure drop measured with a micro-manometer across the test section, was used to calculate the friction factor. The relation between pressure drop and friction factor is given by (4) The fiction factor is normalized by Gnielinski equation fo =[0.79 ln (ReDh)- 1.64]-2 (5) The correlation for thermal performance is given by TP = (Nu / Nuo)/ (f/fo) 1/3 (6) 4. RESULT AND DISCUSSION Heat Transfer Distribution for smooth rectangular duct, rectangular duct with continuous V- shaped ribs and rectangular duct with discrete V- shaped ribs: The Nusselt number was found to increase with increasing Reynolds number. The reason attributed to this behavior is as Reynolds number increases the turbulent mixing is enhanced in the channel, which leads to
  • 5. E-ISSN: 2321–9637 Volume 2, Issue 1, January 2014 International Journal of Research in Advent Technology Available Online at: http://www.ijrat.org 63 effective removal of heat. However, the Nusselt number ratio, which is obtained by normalizing the average Nusselt number with the fully developed turbulent flow in smooth test tube correlated by Dittus Boelter, was found to decrease as shown in Fig 3. In the case of smooth test duct the variation of Nusselt number ratio with increasing Reynolds number is very small as there is no flow separation and reattachments in this case and so Reynolds number does not have any effect on the heat transfer augmentation. Therefore, the Nusselt number ratio for all four Reynolds number follow a similar trend. The Nusselt number ratio was found to be highest for the lowest Reynolds number and lowest for the highest Reynolds number. It was found to vary between 2.15 and 1.1 along the axial direction. 0 0.5 1 1.5 2 2.5 1 2 3 4 X/Dh Nu/Nuo 5000 8000 12500 15600 Fig.3 Effect of Reynolds Number on Heat Transfer Distribution for Smooth Rectangular duct The heat transfer augmentation for rectangular duct with continuous V- shaped ribs was found to increase by factor of 1.7 to 2.1 in comparison to the smooth rectangular duct and by a factor of 1.06 to 1.20 in comparison to the rectangular duct with discrete V- shaped ribs. The increase in heat transfer coefficient is attributed to the induction of cross-stream secondary flow, which results in better turbulent mixing. 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 1 2 3 4 X/Dh Nu/Nuo 5000 8000 12500 15600 Fig.4 Effect of Reynolds Number on Heat Transfer Distribution for Rectangular duct with continuous V- shaped ribs
  • 6. E-ISSN: 2321–9637 Volume 2, Issue 1, January 2014 International Journal of Research in Advent Technology Available Online at: http://www.ijrat.org 64 0 0.5 1 1.5 2 2.5 3 3.5 4 1 2 3 4 X/Dh Nu/Nuo 5000 8000 12500 15600 Fig.5 Effect of Reynolds Number on Heat Transfer Distribution for Rectangular duct with discrete V- shaped ribs Friction Factor Characteristics for smooth rectangular duct, rectangular duct with continuous V- shaped ribs and rectangular duct with discrete V- shaped ribs: The friction factor ratio was found to increase with increase in Reynolds number due to the resistance offered to the flow of fluid. The heat transverse augmentation was found to vary between 1.5-2 for the rectangular duct with discrete V- shaped ribs and 2-2.5 for the rectangular duct with continuous V- shaped ribs. This enhancement in both the cases was accompanied by pressure drop penalty of 1.5 to 3 on the rectangular duct with discrete V- shaped ribs and 3 to 4 on the rectangular duct with continuous V- shaped ribs. The rectangular duct with continuous V- shaped ribs produced 20 % to 40% higher pressure drop when compared to the rectangular duct with discrete V- shaped ribs for the complete range of Reynolds number investigated. Fig. 6 Average Friction Factor Ratio versus Reynolds Number for Various Configurations
  • 7. E-ISSN: 2321–9637 Volume 2, Issue 1, January 2014 International Journal of Research in Advent Technology Available Online at: http://www.ijrat.org 65 Thermal Performance: Thermal performance for the plate with internal ribs is drawn as below in fig. 7, shows that thermal performance is increasing with increase in Reynolds number. But the thermal performance for rectangular duct with discrete V- shaped ribs is poor as compared to the rectangular duct with continuous V- shaped ribs. This is due more turbulence and strong vortex formation in rectangular duct with continuous V- shaped ribs. Also it reflects that thermal performance of rectangular duct with continuous V- shaped ribs is more than one which means applying continuous V- shaped ribs is beneficial to increase heat transfer enhancement. Fig. 7 Variation of Thermal Performance with Reynolds Number for Various Configurations Acknowledgments We are thankful to the Hon. Principal Dr. A.W. Kolhatkar and Head of Department Dr. A. B. Borade, Jawaharalal Darda Institute of Engineering and Technology, Yavatmal, Maharashtra, India for providing Mechanical Engineering Research Laboratory for Experimentation study and their moral support. References [1] M. Sozen and T M. Kuzay (1996), “Enhanced heat transfer in round tubes with porous inserts”, International Journal Heat and Fluid Flow, Vol. 17, pp.124-129 [2] Q. Liao and M.D. Xin (2000), “Augmentation of convective heat transfer inside tubes with three-dimensional internal extended surfaces and twisted-tape inserts”, Chemical Engineering Journal, Vol. 78, pp. 95-105 [3] D. Angirasa (2001), “Experimental investigation of forced convection heat transfer augmentation with metallic porous materials”, International Journal of Heat Mass Transfer, pp. 919-922 [4] H.L. Fu, K.C. Leong, X.Y. Huang and C.Y. Liu (2001), “An experimental study of heat transfer of a porous channel subjected to oscillating flow”, ASME Journal of Heat Transfer, Vol. 123, pp.162-170. [5] S.S Hsieh, M.H. Liu, H.H. Tsai (2003), “Turbulent heat transfer and flow characteristic in a horizontal circular tube with strip- type inserts part-II (heat transfer)”, International Journal of Heat and Mass Transfer, Vol. 46, pp.837-849. [6] B.I. Pavel and A.A. Mohamad (2004), “ An experimental and numerical study on heat transfer enhancement for gas heat exchangers fitted with porous media”, International Journal of Heat and Mass Transfer, Vol. 47, pp.4939-4952. [7] Smith Eiamsa-ard, Chinaruk Thianpong, Petpices Eiamsa-ard and Pongjet Promvonge (2009), “Convective heat transfer in a circular tube with short-length twisted tape insert”, International communications in heat and mass transfer (2009).
  • 8. E-ISSN: 2321–9637 Volume 2, Issue 1, January 2014 International Journal of Research in Advent Technology Available Online at: http://www.ijrat.org 66 [8] Chinaruk Thianpong, Petpices Eiamsa-ard, Khwanchit Wongcharee and Smith Eiamsaard (2009), Compound heat transfer enhancement of a dimpled tube with a twisted tape swirl generator, International Communications in Heat and Mass Heat and Mass Transfer, Vol. 36, pp. 698-704. [9] Whitham, J. M (1896), The effects of retarders in fire tubes of steam boilers, Street Railway, Vol. 12(6), pp. 374. [10] Date, A. W. and Singham, J. R. (1972), “Numerical prediction of friction and heat transfer characteristics of fully developed laminar flow in tubes containing twisted tapes”, Trans. ASME, Journal of Heat Transfer, Vol. 17, pp. 72 [11] S.K.Saha, U.N.Gaitonde and A.W. Date (1989), “Heat transfer and pressure drop characteristics of laminar flow in a circular tube fitted with regularly spaced twisted-tape elements”, Journal of Exp. Thermal Fluid Sci., Vol. 2, pp.310-322. [12] Rao, M. M. and Sastri, V. M. K. (1995), “Experimental investigation for fluid flow and heat transfer in a rotating tube twisted tape inserts”, International Journal of Heat and Mass Transfer, Vol.16, pp.19–28. [13] Sivashanmugam, P. and Suresh, S. (2007), “Experimental studies on heat transfer and friction factor characteristics of turbulent flow through a circular tube fitted with regularly spaced helical screw tape inserts”, Experimental Thermal and Fluid Science, Vol. 31, pp. 301-308. [14] Agarwal, S. K. and Raja Rao, M. (1996), “Heat transfer augmentation for flow of viscous liquid in circular tubes using twisted tape inserts”, International Journal of Heat Mass Transfer, Vol. 99, pp.3547–3557. [15] Peterson, S. C., France, D. M. and Carlson, R. D. (1989), “Experiments in high-pressure turbulent swirl flow”, Trans. ASME, Journal of Heat Transfer, Vol. 108, pp.215–218.